ikm presentation new
TRANSCRIPT
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 1/22
ernalernalernalernal groupgroupgroupgroup
(EXCLUSIVE DISTRIBUTOR AGENT)FOR
INTERNATIONAL KOREAN COMPANY FOR
MEDICAL SYRINGES
DISPOSABLE SYRINGE TECHNICALDISPOSABLE SYRINGE TECHNICAL ANALYSISANALYSIS
100100% Made in Kingdom of Saudi Arabia% Made in Kingdom of Saudi Arabia
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 2/22
CONTENTS
1. PRODUCTS
2. DISPOSABLE SYRINGE ILLUSTRATION
3. OUR PRODUCTS
4. MATERILAS OF GASKET
5. DISCRIPTION FOR HYPODERMIC NEEDLE
.
7. HUB COLOR CODE AND SIZE STANDARDS FOR
NEEDLE
8. STANDARDS IN ACCORDANCE WITH ISO 7886
9. STERILIZATION
10.INDIVIDUAL PACKAGING
11.LABELLING
12.CERTIFICATES
13.QUESTION S
14.THNX 2
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 3/22
PRODUCTS
1. NAME OF PRODUCTSDISPOSABLE SYRINGE WITH DIFFERENT SIZES OF NEEDLES
2. TYPE OF PRODUCTIONFULL -AUTOMATIC PRODUCTION SYSTEM
.DISPOSABLE SYRINGE / Uni-Body / DISPOSABLE NEEDLES
3.1 DISPOSABLE SYRINGES1 cc / 3 cc / 5 cc / 10 cc
3.2 DISPOSABLE NEEDLESFROM 16Gauge TO 30Gauge, LENGTH : FROM 1/2" TO 1 1/2"
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 4/22
DISPOSABLE SYRINGE ILLUSTRATION
CAPP BARRELP GASKETP PLUNGERPNOZZLEP
WINGPBASE LINEPSCALE
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 5/22
OUR PRODUCTS
SYRINGE NEEDLE
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 6/22
MATERIALS OF GASKET
TPE COMPOUND ( COLOR: BLACK )
GRADE : SR-9000 ( SRG-2705 )
PROCESS OIL
MODIFIER ( POLYPROPYLENE )
ANTI OXIDANT
CARBON BLACK
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 7/22
DESCRIPTION FOR HYPODERMIC NEEDLE
APPEARANCE :
NO OBVIOUS SCRATCH, ROUGHNESS AND PARTICLES THERETO.
NEEDLE POINT :
NO BURR ON THE GRIND POINT AND SHOULD BE SHARP ENOUGH DUL
LENGTH :
SHOULD BE WITHIN THE FOLLOWING REQUIREMENTS WHEN THE LENGTHOF CANNULA IS MEASURED BY VERIFIER CALIPERS AND MICRO METER.
OUTER DIAMETER :WITHIN TO = 8%, TO -3% WHEN THE MEASUREMENT IS PERFORMED.
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 8/22
MATERIAL DESCRIPTION FOR NEEDLE PARTS TUBE :
AUTHENTIC STAINLESS STEEL 304 OF TYPE 10, 11, 16 IN ACCORDANCE
WITH ISO 683-13 ( STANDARDS : KSD-3698 )
HUB :
POLYPROPYLENE , MEDICAL INJECTION, VIRGIN GRADE
( STANDARDS : KSM-3010 )
CAP :POLYPROPYLENE , MEDICAL INJECTION, VIRGIN GRADE
( STANDARDS : KSM-3010 )
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 9/22
HUB COLOUR CODE & SIZE STANDARD
FOR NEEDLE
GAUGE HUB COLOR GAUGE HUB COLOR
18G PINK 19 G BROWN
20G LIGHT YELLOW 21 G GREEN
22G GREY 23 G SKY BLUE
25G ORANGE 26 G LIGHT BROWN
27G LIGHT GREY
[ Specification in accordance with ISO 594-2 , 6009 , 7864 , 9626 ]
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 10/22
STANDARDS
[ IN ACCORDANCE WITH ISO7886 ]1. APPEARANCE
AIR BUBBLES, CRACKS OR ANY OTHER DEFECT SHOULD NOT BE
DISTINCTLY FOUND IN BARREL PARTS.
2.DIMENSIONS :
THE LENGTH OF THE BARREL SHALL BE SUCH THAT THE SYRINGE HAS A
NOMINAL CAPACITY.
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 11/22
STANDARDS
[ IN ACCORDANCE WITH ISO7886 ]3. FINGER GRIPS :
THE OPEN END OF THE BARREL SHALL BE PROVIDED WITH FINGER GRIPS
THAT SHALL ENSURE THAT THE SYRINGE WILL NOT ROLL MORE THAT 180°WHEN IT IS PLACED ON A FLAT SURFACE AT AN ANGLE OF 10° TO THE
HORIZONTAL.
FINGER GRIPS SHOULD BE OF ADEQUATE SIZE, SHAPE AND STRENGTHFOR THE INTENDED PURPOSE AND SHOULD ENABLE THE SYRINGE TO BE
HELD SECURITY DURING USE.
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 12/22
STANDARDS
[ IN ACCORDANCE WITH ISO7886 ]4. PRINTING ON BARREL
GRADUATED SCALES AND OTHER WORKING SHOULD BE PRINTED
CLEARLY AND NOT BE EARED EASILY.
CAPACITY OF THE SYRINGE AT THE GRADUATION LINE FURTHEST
FROM THE ZERO GRADUATION LINE.
MAXIUM USABLE CAPACITY : CAPACITY OF THE SYRINGE WHENTHE PISTON IS DRAWN BACK TO ITS MAXIUM USABLE CAPACITY :
FURTHEST FUNCTIONAL PISTON.
FIDUCIAL LINE : LINE CIRCUMSCRIBING THE END OF THE PISTON FOR
DETERMING THE FIDUCIAL LINE : CAPACITY CORRESPONDING TO ANYSCALE READING OF THE SYRINGE.
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 13/22
STANDARDS
[ IN ACCORDANCE WITH ISO7886 ]5. PLUNGER SEAL (GASKET)
THE GASKET SHALL NOT BECOME DISLODGED FROM THE PLUNGER
UNDER NORMAL CONDITIONS OF USE AND SHOULD NOT BE FOUNDDUST AND DREGS OF ITSELF.
6. ACCURACY OF CAPACITY
FULLY INSERT THE PLUNGER TO THE BOTTOM OF BARREL AND TAKEMEASURE THE SOLUTION EXPELLED FROM THE SYRINGE.
THE LINE OF CAPACITY SHALL BE IN ACCORDANCE WITH FOLLOWING1 cc TO 3 cc : +5%
5 cc TO 50 cc : +4%
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 14/22
STANDARDS
[ IN ACCORDANCE WITH ISO7886 ]7. DESIGN OF THE PLUNGER AND PISTON
THE DESIGN OF THE PLUNGER AND PUSH-BUTTON OF THE SYRINGE SHALL BE SUCH THAT,
WHEN THE BARREL IS HELD IN ONE HAND, THE PLUNGER CAN BE DEPRESSED BY THE THUMBOF THAT HAND, WHEN TESTED IN ACCORDANCE WITH ISO7886 AANNEX B, THE PISTONSHALL BE NOT BECOME DETACHED FROM THE PLUNGER .THE PLUNGER SHOULD BE OF A
LENGTH ADEQUATE TO ALLOW THE PISTON TRAVERSE THE FULL LENGTH OF BARREL, BUT ITSHOULD NOT BE POSSIBLE EASILY TO WITHDRAW THE PLUNGER COMPLETELY FROM
.
THE PROJECTION OF THE PLUNGER AND THE CONFIGURATION OF THE PUSH-BUTTONSHOULD BE SUCH AS TO ALLOW THE PLUNGER TO BE OPERATED WITHOUT DIFFICULTY.
WHEN THE FIDUCIAL LINE OF THE PISTON COINCIDES WITH THE ZERO GRADUATION LINETHE PREFERRED MINIMUM LENGTH OF THE PLUNGER FROM THE SURFACE OF THE FINGER
GRIPS NEARER TO THE PUSH-BUTTON SHOULD BE ;
8mm FOR SYRINGES OF NOMINAL CAPACITY UP TO BUT EXCLUDING 2ml ;
9mm FOR THE SYRINGES PF NOMINAL CAPACITY OF 2ml UP TO BUT EXCLUDING 5ml ;
12.5mm FOR THE SYRINGES OF NOMINAL CAPACITY OF 5ml AND GREATER.
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 15/22
STANDARDS
[ IN ACCORDANCE WITH ISO7886 ]8. FIT OF PISTON IN BARREL
WHEN THE SYRINGE IS FILLED WITH EATER AND HELD VERTICALLY WITHFIRST ONE END THEN THE OTHER END UP PERMOST, THE PLUNGER SHALL
NOT MOVE BY REASON OF ITS OWN MASS.
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 16/22
STERILIZATION
SHOULD BE ELIGIBLE WHEN TEST IS PERFORMED AS PER STERILITY TEST
METHOD IN ACCORDANCE WITH EN550 / DIN : 1994
GAS USED : ETHYLENE OXIDE GAS (20%)
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 17/22
INDIVIDUAL PACKAGING
SHOULD BE UNDAMAGED OR UNOPENED BEFORE USE.
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 18/22
LABELLINGTHE PRIMARY CONTAINER , SECONDARY CONTAINER AND STORGAE
CONTAINER APPEAR AS FOLLOW:
DESCRIPTION OF THE CONTENTS INCLUDING NOMINAL CAPACITYAND THE TYPE OF NOZZLE
THE WORD " STERILE "
THE WORDS : FOR SINGLE USE :
THE LOT NO. , PREFIXED BY THE WORD " LOT "
THE NAME, TRADE MARK, TRADE NAME OR LOGO OF THEMANUFACTURER
THE DATE OF STERILIZATION IN ACCORDANCE WITH ISO 8601
MANUFACTURING DATE OR STERILIZATION DATE
INFORMATION FOR THE HANDLING, STORAGE AND TRANSPORTATION OF THE
CONTENTS.
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 19/22
ISO CERTIFICATE
SWISS ISO 9001:2008
FOR DESIGN, PRODUCT,
SALES AND SERVICE OF
DISPOSABLE SYRINGES
.
19
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 20/22
SAFDA LICENSE
20
METMET 112112 Global Climate ChangeGlobal Climate Change
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 21/22
5/10/2018 Ikm Presentation New - slidepdf.com
http://slidepdf.com/reader/full/ikm-presentation-new 22/22
THANK YOU