IECEx Quality Assessment Report QAR Free Reference No.: 12CA11884 Certification Body: UL LLC 00-IC-F0068 Issue 9.0 Page 1 of 6 Copyright UL LLC. All rights reserved. May not be reproduced without permission. UL PROPRIETARY AND CONFIDENTIAL. FOR UL INTERNAL USE ONLY. This document is controlled and has been released electronically. The version on the UL intranet is the up-to-date document. Hard copies are uncontrolled and may not be up-to-date. Users of hard copies should confirm the revision by comparing it with the electronically controlled version. Applicant: Name: Baccara Automation Control Address: Kvutzat Geva, 18915 Israel Site(s) Audited: Same as Applicant Address(es): Total Number of Employees: 300 Number of Employees Involved in the Production of Ex Products: 10 Product Type(s) Covered Under Scope: Solenoid Valves Protection Method(s): d e i m n o p q tD iD mD pD ta tb tc c* b* * ATEX only. Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans and Quality System to the requirements of: EN 13980:2002 Annex IV Annex VI Annex VII IECEx OD 005-1, Edition 1.0 IECEx Conformity Mark License: IECEx OD 022, Version 1 & IECEx OD 023, Version 1 INMETRO Portaria 179:2010 Other (specify) Conclusions: PQAN/QAR/IECEx Conformity Mark License/INMETRO Audit Report to be issued/maintained; system in compliance (no findings). PQAN/QAR/IECEx Conformity Mark License/INMETRO Audit Report to be issued/maintained; satisfactory documentary evidence supporting effective corrective action has been provided to resolve all findings. Corrective action to be verified at next surveillance visit. PQAN/QAR/IECEx Conformity Mark License/INMETRO Audit Report to be maintained until follow-up visit to verify that corrective actions to address findings have been effectively documented and implemented. PQAN/QAR/IECEx Conformity Mark License/INMETRO Audit Report to be issued indicating that quality system no longer meets the requirements (this may require suspension or cancellation of any certificates). Audit Team Leader: Signature: Date (YYYY-MM-DD): 2012-10-04 Certification Body Representative: Name: Paul T. Kelly Signature: Date (YYYY-MM-DD): 2012-10-04

Upload: others

Post on 26-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

IECEx Quality Assessment Report

QAR Free Reference No.:

12CA11884

Certification Body: UL LLC

00-IC-F0068 – Issue 9.0 Page 1 of 6 Copyright UL LLC. All rights reserved. May not be reproduced without permission. UL PROPRIETARY AND CONFIDENTIAL. FOR UL INTERNAL USE ONLY. This document is controlled and has been released electronically. The version on the UL intranet is the up-to-date document. Hard copies are uncontrolled and may not be up-to-date. Users of hard copies should confirm the revision by comparing it with the electronically controlled version.

Applicant: Name: Baccara Automation Control Address: Kvutzat Geva, 18915 Israel

Site(s) Audited: Same as Applicant

Address(es): Total Number of Employees: 300 Number of Employees Involved in the Production of Ex Products:

10

Product Type(s) Covered Under Scope: Solenoid Valves Protection Method(s):

d e i m n o p q tD iD mD pD ta tb tc c* b*

* ATEX only. Scope of Audit: Initial Assessment Reassessment Surveillance Revision

Audit of Product Quality Plans and Quality System to the requirements of: EN 13980:2002 Annex IV Annex VI Annex VII IECEx OD 005-1, Edition 1.0 IECEx Conformity Mark License: IECEx OD 022, Version 1 & IECEx OD

023, Version 1 INMETRO Portaria 179:2010

Other (specify) Conclusions: PQAN/QAR/IECEx Conformity Mark License/INMETRO Audit Report to

be issued/maintained; system in compliance (no findings). PQAN/QAR/IECEx Conformity Mark License/INMETRO Audit Report to

be issued/maintained; satisfactory documentary evidence supporting effective corrective action has been provided to resolve all findings. Corrective action to be verified at next surveillance visit.

PQAN/QAR/IECEx Conformity Mark License/INMETRO Audit Report to be maintained until follow-up visit to verify that corrective actions to address findings have been effectively documented and implemented.

PQAN/QAR/IECEx Conformity Mark License/INMETRO Audit Report to be issued indicating that quality system no longer meets the requirements (this may require suspension or cancellation of any certificates).

Audit Team Leader: Signature:

Date (YYYY-MM-DD): 2012-10-04

Certification Body Representative:

Name: Paul T. Kelly Signature:

Date (YYYY-MM-DD): 2012-10-04

Page 2: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

IECEx Quality Assessment Report

QAR Free Reference No.:

12CA11884

Certification Body: UL LLC

00-IC-F0068 – Issue 9.0 Page 2 of 6 Copyright UL LLC. All rights reserved. May not be reproduced without permission. UL PROPRIETARY AND CONFIDENTIAL. FOR UL INTERNAL USE ONLY. This document is controlled and has been released electronically. The version on the UL intranet is the up-to-date document. Hard copies are uncontrolled and may not be up-to-date. Users of hard copies should confirm the revision by comparing it with the electronically controlled version.

Audit Information Type of Audit: Type A Initial assessment/reassessment with a certified QS

Type B Initial assessment/reassessment without a certified QS Type C Surveillance with a certified QS Type D Surveillance without a certified QS

QS Registration: ISO 9001 Registrar: IQNet

Body accredited by IAF Member:

Yes

Certificate No.: IL-55193 Expiration Date: 2013-12-01

N/A Auditor(s): Team Leader: Nick Voss

Other (Role):

N/A

Audit Date(s): 2012-08-16 to 2012-08-17 Next Audit Date(s) (YYYY-MM): 2014-02 Special focus on (if applicable): N/A Reference Documents: (include quality manual and other documents or procedures referenced during the audit)

Audit Checklist: No.: 00-EX-F0400

Issue: 5.1

Integrated Quality System Guide:

No. : Not Available Revision: 8

Explosion Proof Coil Assembly Instructions:

No.: WP 3021 Revision: 3

Corrective Action Report:

No.: 38812 Revision: N/A

Supplier Quality Assessment:

No.: 120 Revision: 2011-06-30

Document Control – Engineering Change Order (ECO):

No.: QP05-06 Revision: 5

Control of Records:

No.: QP03-02 Revision: 6

ECO Form: No.: 200 Revision: N/A Non-Conforming Product:

No.: QP07-01 Revision: 11

Control of non-conforming product:

No.: QP01-01 Revision: 6

Target and Goals for EHS, ISO 9001-:2008:

No.: EHS 4.3.4-4.3.3 Revision: 8

Structure and Responsibility:

No.: QP01-03 Revision: 8

Page 3: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

IECEx Quality Assessment Report

QAR Free Reference No.:

12CA11884

Certification Body: UL LLC

00-IC-F0068 – Issue 9.0 Page 3 of 6 Copyright UL LLC. All rights reserved. May not be reproduced without permission. UL PROPRIETARY AND CONFIDENTIAL. FOR UL INTERNAL USE ONLY. This document is controlled and has been released electronically. The version on the UL intranet is the up-to-date document. Hard copies are uncontrolled and may not be up-to-date. Users of hard copies should confirm the revision by comparing it with the electronically controlled version.

For ATEX: List of EC-Type Examination Certificates (of the Manufacturer) covered by the audit

No.: DEMKO 08 ATEX 143928X

Last revision (date):

2009-11-09

For IECEx: List of CoCs covered by the audit

No.: N/A Last revision (date):

For INMETRO: List of CoCs covered by the audit

No.: N/A Last revision (date):

Nonconformities: (as detailed in the attached Nonconformity (NCR) Report(s), when applicable)

None Minor NCR No(s).: NV-1, NV-2, NV-3, NV-4, NV-5, NV-6,

NV-7, NV-8, NV-9 Major NCR No(s).:

Observations: None

Other: No(s).: 1, 2, 3, 4 Documentation Review and Assessment of Implementation:

Clause No. Clause Description

Cla

use

Asse

ssed

?

Com

men

t R

efer

ence

(C

-1, C

-2, e

tc.)

Nonconformity Information N

CR

Ref

eren

ce

(JM

-1, J

M-2

, etc

.) Department / Area Audited, In Relation to NCR Ye

s N

o N

/A

4.1 General requirements X 4.2.1 Documentation requirements X 4.2.2 Quality manual X

4.2.3 Control of documents X NV-1, NV-6 Documentation

4.2.4 Control of records X 5.1 Management commitment X 5.2 Customer focus X 5.3 Quality policy X 5.4.1 Quality objectives X NV-8 Documentation 5.4.2 Quality management system planning X 5.5.1 Responsibility and authority X NV-9 Documentation 5.5.2 Management representative X 5.5.3 Internal communication X

Page 4: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

IECEx Quality Assessment Report

QAR Free Reference No.:

12CA11884

Certification Body: UL LLC

00-IC-F0068 – Issue 9.0 Page 4 of 6 Copyright UL LLC. All rights reserved. May not be reproduced without permission. UL PROPRIETARY AND CONFIDENTIAL. FOR UL INTERNAL USE ONLY. This document is controlled and has been released electronically. The version on the UL intranet is the up-to-date document. Hard copies are uncontrolled and may not be up-to-date. Users of hard copies should confirm the revision by comparing it with the electronically controlled version.

Clause No. Clause Description

Cla

use

Asse

ssed

?

Com

men

t R

efer

ence

(C

-1, C

-2, e

tc.)

Nonconformity Information

NC

R R

efer

ence

(J

M-1

, JM

-2, e

tc.)

Department / Area Audited, In Relation to NCR Ye

s N

o N

/A

5.6.1 Management review - General X NV-9 Documentation related to 5.5.1

5.6.2 Review input X 5.6.3 Review output X 6.1 Provision of resources X 6.2.1 Human resources - General X 6.2.2 Competence, awareness and training X 6.3 Infrastructure X 6.4 Work environment X 7.1 Planning of product realization X

7.2.1 Determination of requirements related to the product

X

7.2.2 Review of requirements related to the product

X

7.2.3 Customer communication X 7.3 Design and development X 7.4.1 Purchasing process X 7.4.2 Purchasing information X NV-5 Purchasing 7.4.3 Verification of purchased product X NV-2 Incoming Inspection

7.5.1 Control of production and service provision

X

7.5.2 Validation of processes for production and service provision

X

7.5.3 Identification and traceability X 7.5.4 Customer property X 7.5.5 Preservation of product X NV-4 Shipping

7.6 Control of monitoring and measuring devices

X

8.1 Measurement, analysis and improvement - General

X

8.2.1 Customer Satisfaction X

8.2.2 Internal audit X NV-7 Internal Audit, Documentation

8.2.3 Monitoring and measurement of processes

X

8.2.4 Monitoring and measurement of product X NV-3 Testing 8.3 Control of nonconforming product X 8.4 Analysis of data X 8.5.1 Continual improvement X 8.5.2 Corrective action X

Page 5: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

IECEx Quality Assessment Report

QAR Free Reference No.:

12CA11884

Certification Body: UL LLC

00-IC-F0068 – Issue 9.0 Page 5 of 6 Copyright UL LLC. All rights reserved. May not be reproduced without permission. UL PROPRIETARY AND CONFIDENTIAL. FOR UL INTERNAL USE ONLY. This document is controlled and has been released electronically. The version on the UL intranet is the up-to-date document. Hard copies are uncontrolled and may not be up-to-date. Users of hard copies should confirm the revision by comparing it with the electronically controlled version.

Clause No. Clause Description

Cla

use

Asse

ssed

?

Com

men

t R

efer

ence

(C

-1, C

-2, e

tc.)

Nonconformity Information

NC

R R

efer

ence

(J

M-1

, JM

-2, e

tc.)

Department / Area Audited, In Relation to NCR Ye

s N

o N

/A

8.5.3 Preventive action X

A.2 Information relevant to particular types of protection - General

X

A.3 Ex d - Flameproof enclosures X A.4 Ex i - Intrinsic safety X A.5 Ex e - Increased safety X A.6 Ex p - Pressurized apparatus X A.7 Ex m - Encapsulation X A.8 Ex o - Oil immersion X A.9 Ex q - Powder filling X

A.10 Ex t – Dust ignition protection by enclosure

X

A.11 Gas Detectors X A.12 Flame Arresters X A.13 Type of protection 'n' X A.14 Heat Tracing X A.15 Nozzles X

A.16 Metering Pumps, Dispensers and Remote Pumping Units

X

A.17 Safe Breaks X A.18 Shear Valves X A.19 Swivels X A.20 Submersible Pump Assemblies X

B Verification criteria for sintered components

X

C.1 Internal procedure for use of the mark X C.2 Design of the mark X

C.3 Mark used only with associated certificates

X

C.4 Promotional material X Comments: Comment Ref. Comment 1. A new standard, ISO/IEC 80079-34, was recently

published that will replace EN 13980 and IECEx OD-005-1. During the next audit, the requirements of 80079-34 will be applied.

2. The purchase order for the coil wire included a drawing that stated "SEE 'ADDITIONAL REQUIREMENT' – DRAWING NUMBER 3033-A". Neither the drawing nor the "Additional drawing" had drawing numbers. It is suggested that all

Page 6: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

IECEx Quality Assessment Report

QAR Free Reference No.:

12CA11884

Certification Body: UL LLC

00-IC-F0068 – Issue 9.0 Page 6 of 6 Copyright UL LLC. All rights reserved. May not be reproduced without permission. UL PROPRIETARY AND CONFIDENTIAL. FOR UL INTERNAL USE ONLY. This document is controlled and has been released electronically. The version on the UL intranet is the up-to-date document. Hard copies are uncontrolled and may not be up-to-date. Users of hard copies should confirm the revision by comparing it with the electronically controlled version.

drawings, especially those being sent with purchase orders, be numbered to create a clear reference.

3. Clauses 4.2.3 (b) and (d) state that a documented procedure and system must be in place to ensure manufacturer's documents (related drawings, sale literature, etc.) must be compatible with equipment documents (schedule drawings). The ECO process does ensure this is happening but I suggest a formal procedure is written up to describe the "Where Used" process that occurs as discussed during the audit.

4. Further to NCR NV-7, it is recommended that all areas of the quality policy that reference ISO 9001:2008 are reviewed and the standards EN 13980:2002 and IECEx OD 005-1, 1st edition and their requirements are added as applicable.

Page 7: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans
Page 8: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

MR. REUBEN PEREZ

CFS INTERNATIONAL CO

INDUSTRIAL ZONE NO.3

POB 262 Date: 2013/03/06

27071 MAALOT ISRAEL Subscriber: 100576826

PartySite: 2717346

File No: MH12494

Project No: 12NK05133

PD No: 13O09733

Type: R

PO Number: OMER ROTMAN

Subject: Procedure And/Or Report Material

The following material resulting from the investigation under the above numbers is enclosed.

Issue

Date Vol Sec Pages Revised Date

1 Revised Index Page(s) 1 2013/03/01

1985/03/05 1 1 Cert of Compliance

1985/03/05 1 1 Cover Page(s)

1985/03/05 1 1 New Description Page(s) 1B,1C,1D,1AE 2013/03/01

1985/03/05 1 1 Revised Description Page(s) 1,1A,2,3,4,5,7,8 2013/03/01

1985/03/05 1 1 Revised Figure(s) 1,2,3,4 2013/03/01

1985/03/05 1 1 New Illustration(s) 8B 2013/03/01

1985/03/05 1 1 Revised Illustration(s) 1,2,3,4,5,6A,7A,8A,9,10,11,12,13,14,A 2013/03/01

1985/03/05 1 1 New Test Record 4 2013/03/01

1985/03/06 1 2 Cover Page(s)

1985/03/06 1 2 New Description Page(s) 1A 2013/03/01

Legible image may be viewed online

Please file revised pages and illustrations in place of material of like identity. New material

should be filed in its proper numerical order.

NOTE: Follow-Up Service Procedure revisions DO NOT include Cover Pages, Test Records and Conclusion

Pages. Report revisions DO NOT include Authorization Pages, Indices, Section General Pages and

Appendixes.

Please review this material and report any inaccuracies to UL's Customer Service Professionals.

Contact information for all of UL's global offices can be found at

http://www.ul.com/global/eng/pages/corporate/contactus.

If you’d like to receive updated materials FASTER, UL offers electronic access and/or delivery of

this material. For more details, contact UL's Customer Service Professionals as shown above.

This material is provided on behalf of UL LLC(UL) or any authorized licensee of UL.

NBK File

Page 9: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

ADDENDUM TO TRANSMITTAL LETTER

MR. REUBEN PEREZ

CFS INTERNATIONAL CO

INDUSTRIAL ZONE NO.3

POB 262 Date: 2013/03/06

27071 MAALOT ISRAEL Subscriber: 100576826

PartySite: 2717346

File No: MH12494

Project No: 12NK05133

PD No: 13O09733

Type: R

PO Number: OMER ROTMAN

Subject: Procedure And/Or Report Material

The following material resulting from the investigation under the above numbers is enclosed.

Issue

Date Vol Sec Pages Revised Date

1985/03/06 1 2 Revised Description Page(s) 1,2,3,4,5,6,7 2013/03/01

1985/03/06 1 2 Cert of Compliance

1985/03/06 1 2 Revised Figure(s) 1,2,3 2013/03/01

1985/03/06 1 2 New Illustration(s) 5A 2013/03/01

1985/03/06 1 2 Revised Illustration(s) 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 2013/03/01

,A

1986/03/06 1 New Test Record 2 2013/03/01

1986/03/06 1 Conclusion Page(s)

Page 10: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AEE:str NKDLS

File MH12494 Vol. 1 Index Page 1 Issued: 1985-03-053

Revised: 2013-03-01

Cat. No. Section

GEM-A 1

GEM-H

GEM-V

GEM-S 2

*

I N D E X _ _ _ _

Page 11: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20130305-MH12494

Report Reference MH12494-19830305

Issue Date 2013-MARCH-05

William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus

Page 1 of 2

Issued to: BACCARA GEVA AGRICULTURE CORPORATION

SOCIETY LTD

KIBBUTZ GEVA

18915 KVUTZAT GEVA ISRAEL

This is to certify that

representative samples of

COMPONENT - VALVES, ELECTRICALLY OPERATED

See next page

Have been investigated by UL in accordance with the

Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 429-STANDARD FOR ELECTRICALLY OPERATED VALVES

Additional Information: See the UL Online Certifications Directory at

www.ul.com/database for additional information

Only those products bearing the UL Recognized Component Mark should be considered as being covered by UL's Recognition and Follow-Up Service.

The UL Recognized Component Mark generally consists of the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory. As a supplementary means of identifying products that have been produced under UL’s Component Recognition Program, UL’s Recognized Component Mark: , may be used in conjunction with the required Recognized Marks. The Recognized Component Mark is required when specified in the UL Directory preceding the recognitions or under “Markings” for the individual recognitions.

Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC. Look for the UL Recognized Component Mark on the product.

Page 12: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20130305-MH12494

Report Reference MH12494-19830305

Issue Date 2013-MARCH-05

William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus

Page 2 of 2

General Purpose Valve, Cat. No. GEM-A, followed by 1, 2 or 3, followed by 11 or 21,

followed by 3 or 4, followed by 3, 5, or 6, followed by N, V, E, K, or T, followed by 0 or

2, followed by 2, 3, 4, 5, 6, or 7, followed by 1, 2, or 3, followed by 0, or 4.

General Purpose Valve, Cat. No. GEM-H, followed by 1, followed by 3 or 4, followed by 3,

5, or 6, followed by N, V, or E, followed by 0 or 1, followed by 2, 3, 4, 5, 6, or 7,

followed by 1, 2, or 3, followed by 0 or 4.

General Purpose Valve, Cat. No. GEM-V, followed by any number, followed by any number,

followed by 10 or 11, followed by 1, 2, or 3, followed by 3, or 4, followed by 3, 5, or 6,

followed by N, V, or E, followed by 0 or 2, followed by 2, 3, 4, 5, 6, or 7, followed by

1, 2, or 3, followed by 0, or 4.

Page 13: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494

Project 84NK22873

Issued: March 5, 1985

Revised: March 1, 2013

REPORT

on

COMPONENT - ELECTRICALLY OPERATED VALVES

*Baccara Geva Agriculture Corporation Society LTD.

Kvutzat Geya, Israel

Copyright © 1985 Underwriters Laboratories Inc.

Underwriters Laboratories Inc. authorizes the above named company to

reproduce this Report provided it is reproduced in its entirety.

*Underwriters Laboratories Inc. authorizes the above named company to

reproduce that portion of this Report consisting of this Cover Page

through Page 3.

Page 14: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 1 Issued: 1985-03-053

and Report Revised: 2013-03-01

PRODUCT COVERED:

* USR - General Purpose Valve, Cat. No. GEM-A, followed by 1, 2 or 3,

followed by 11 or 21, followed by 3 or 4, followed by 3, 5, or 6, followed by

N, V, E, K, or T, followed by 0 or 2, followed by 2, 3, 4, 5, 6, or 7,

followed by 1, 2, or 3, followed by 0, or 4.

* USR - General Purpose Valve, Cat. No. GEM-H, followed by 1, followed by

3 or 4, followed by 3, 5, or 6, followed by N, V, or E, followed by 0 or 1,

followed by 2, 3, 4, 5, 6, or 7, followed by 1, 2, or 3, followed by 0 or 4.

* USR - General Purpose Valve, Cat. No. GEM-V, followed by any number,

followed by any number, followed by 10 or 11, followed by 1, 2, or 3, followed

by 3, or 4, followed by 3, 5, or 6, followed by N, V, or E, followed by 0 or

2, followed by 2, 3, 4, 5, 6, or 7, followed by 1, 2, or 3, followed by 0, or

4.

GENERAL:

These are direct - acting, 3-way valves of both normally - open and

normally - closed types, intended to control water or air.

GLOSSARY:

R/C - Recognized Component.

USR - Investigated to UL 429.

*

DESCRIPTION _ _ _ _ _ _ _ _ _ _

Page 15: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 1A Issued: 1985-03-05

and Report Revised: 2013-03-01

NOMENCLATURE 1:

Cat No.

A. Designates Basic Family of Valves

Always “GEM-A”

B. Designates Valve Body Material

1 – Mazak

2 – Brass

3 – Stainless Steel

C. Designates Port Type and Size

11 – 1/8” NPT

21 – 1/4” NPT

D. Designates Valve Type

3 – 3 Way Normally Closed

4 – 3 Way Normally Open

E. Designates Orifice Size

3 – 1.6 mm (0.063 in)

5 – 2.4 mm (0.094 in)

6 - 3.0 mm (0.118 in)

F. Designates Seal Material

N – NBR

V – Viton

E – EPDM

K – Kalrez

T - PTFE

G. Designates Manual Override

0 – None

2 - Slot

H. Designates Voltage Rating

2 – 12 Volts

3 – 24 Volts

4 – 48 Volts

5 – 110 Volts

6 – 120 Volts

7 – 230 Volts

I. Designates Power and Frequency rating

1 – 9 Watts 50 Hz

2 – 9 Watts 60 Hz

3 – 10 Watts, DC

J. Designates Connector Type

0 - None

4 – Flying leads

GEM-A - 2 11 3 5 N 2 - 3 3 4

A B C D E F G H I J

Page 16: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 1AE Issued: 1985-03-053

and Report New: 2013-03-01

RATINGS:

Ambient Temperature: +50°C

Fluid Temperature: +70°C.

Fluid Types: Air and water

Maximum Body Pressure: 176.4 psi

Maximum Operating Pressure Differential: See Table Below

Electrical:

Potential

(Volts)

Frequency

(Hz)

Power

(Watts)

12 50/60 9

24 50/60 9

48 50/60 9

110 50/60 9

120 50/60 9

230 50/60 9

12 DC 10

24 DC 10

Page 17: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 1B Issued: 1985-03-05

and Report New: 2013-03-01

NOMENCLATURE 2:

Cat No.

A. Designates Basic Family of Valves

Always “GEM-H”

B. Designates Valve Body Material

1 – Mazak

C. Designates Valve Type

3 – 3 Way Normally Closed

4 – 3 Way Normally Open

D. Designates Orifice Size

3 – 1.6 mm (0.063 in)

5 – 2.4 mm (0.094 in)

6 - 3.0 mm (0.118 in)

E. Designates Seal Material

N – NBR

V – Viton

E – EPDM

F. Designates Manual Override

0 – None

1 – 90° turn

G. Designates Voltage Rating

2 – 12 Volts

3 – 24 Volts

4 – 48 Volts

5 – 110 Volts

6 – 120 Volts

7 – 230 Volts

H. Designates Power and Frequency rating

1 – 9 Watts, 50 Hz

2 – 9 Watts, 60 Hz

3 – 10 Watts, DC

I. Designates Connector Type

0 - None

4 – Flying leads

GEM-H - 1 3 3 N 0 - 3 1 4

A B C D E F G H I

Page 18: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1. Sec. 1 Page 1C Issued: 1985-03-05

and Report New: 2013-03-01

NOMENCLATURE 3:

Cat No.

A. Designates Basic Family of Valves

Always “GEM-V”

B. Designates Number of Valves on the End-Product Manifold

Any positive integer

C. Designates Number of Stations on the End-Product Manifold.

Any positive integer, Value of 0 indicates no manifold is used

D. Designates manifold Port Type and Size

10 – 1/8” BSP

11 – 1/8” NPT

E. Designates Valve Body Material

1 – Mazak

2 – Brass

3 – Stainless Steel

F. Designates Valve Type

3 – 3 Way Normally Closed

4 – 3 Way Normally Open

G. Designates Orifice Size

3 – 1.6 mm (0.063 in)

5 – 2.4 mm (0.094 in)

6 - 3.0 mm (0.118 in)

H. Designates Seal Material

N – NBR

V – Viton

E – EPDM

I. Designates Manual Override

0 – None

2 – Slot

J. Designates Voltage Rating

2 – 12 Volts

3 – 24 Volts

4 – 48 Volts

5 – 110 Volts

6 – 120 Volts

7 – 230 Volts

GEM-V - 6 / 6 - 10 1 3 2 V 2 - 2 2 4

A B C D E F G H I J K L

Page 19: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 1D Issued: 1985-03-05

and Report New: 2013-03-01

A. Designates Power and Frequency rating

1 – 9 Watts, 50 Hz

2 – 9 Watts, 60 Hz

3 – 10 Watts, DC

B. Designates Connector Type

0 - None

4 – Flying leads

Page 20: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 2 Issued: 1985-03-053

and Report Revised: 2013-03-01

*

Basic Catalog:

Series Valve Type Orifice Size,

mm(in.)

Maximum Operating

Pressure

Differential (PSI)

GEM-A-X1X33XX-XXX N.C. 1.6 (0.063) 176.4

GEM-A-X1X35XX-X3X N.C. 2.4 (0.094) 117.6

GEM-A-X1X35XX-X1X N.C. 2.4 (0.094) 147

GEM-A-X1X35XX-X2X N.C. 2.4 (0.094) 147

GEM-A-X1X36XX-X3X N.C. 3.0 (0.118) 80.9

GEM-A-X1X36XX-X1X N.C. 3.0 (0.118) 88.2

GEM-A-X1X36XX-X2X N.C. 3.0 (0.118) 88.2

GEM-A-X1X43XX-XXX N.O. 1.6 (0.063) 176.4

GEM-A-X1X45XX-X3X N.O. 2.4 (0.094) 117.6

GEM-A-X1X45XX-X1X N.O. 2.4 (0.094) 147

GEM-A-X1X45XX-X2X N.O. 2.4 (0.094) 147

GEM-A-X1X46XX-X3X N.O. 3.0 (0.118) 88.2

GEM-A-X1X46XX-X1X N.O. 3.0 (0.118) 102.9

GEM-A-X1X46XX-X2X N.O. 3.0 (0.118) 102.9

GEM-A-X2X33XX-XXX N.C. 1.6 (0.063) 176.4

GEM-A-X2X35XX-XXX N.C. 2.4 (0.094) 176.4

GEM-A-X2X36XX-XXX N.C. 3.0 (0.118) 176.4

GEM-A-X2X43XX-XXX N.O. 1.6 (0.063) 176.4

GEM-A-X2X45XX-XXX N.O. 2.4 (0.094) 176.4

GEM-A-X2X46XX-XXX N.O. 3.0 (0.118) 176.4

GEM-V-XX1XX33XX-XXX N.C. 1.6 (0.063) 176.4

GEM-V-XX1XX33XX-X3X N.C. 1.6 (0.063) 176.4

GEM-V-XX1XX35XX-X3X N.C. 2.4 (0.094) 117.6

GEM-V-XX1XX35XX-X1X N.C. 2.4 (0.094) 147

GEM-V-XX1XX35XX-X2X N.C. 2.4 (0.094) 147

GEM-V-XX1XX36XX-X3X N.C. 3.0 (0.118) 80.9

GEM-V-XX1XX36XX-X1X N.C. 3.0 (0.118) 88.2

GEM-V-XX1XX36XX-X2X N.C. 3.0 (0.118) 88.2

GEM-V-XX1XX43XX-XXX N.O. 1.6 (0.063) 176.4

GEM-V-XX1XX45XX-X3X N.O. 2.4 (0.094) 117.6

GEM-V-XX1XX45XX-X1X N.O. 2.4 (0.094) 147

GEM-V-XX1XX45XX-X2X N.O. 2.4 (0.094) 147

GEM-V-XX1XX46XX-X3X N.O. 3.0 (0.118) 88.2

GEM-V-XX1XX46XX-X1X N.O. 3.0 (0.118) 102.9

GEM-V-XX1XX46XX-X2X N.O. 3.0 (0.118) 102.9

GEM-H-133XX-X3X N.C. 1.6 (0.063) 117.6

GEM-H-133XX-X1X N.C. 1.6 (0.063) 147

GEM-H-133XX-X2X N.C. 1.6 (0.063) 147

Page 21: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 3 Issued: 1985-03-053

and Report Revised: 2013-03-01

*TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE USE):

*Use - For use only in products where the acceptability of the

combination is determined by UL LLC.

USR – Indicates investigation to UL Standard for Electrically Operated

Valves, UL 429, Fifth Edition.

Conditions of Acceptability:

1. These valves are for use within other equipment which provide an

adequate electrical enclosure.

2. The spade terminals are not intended for field wiring.

3. The suitability of the grounding spade terminal shall be

determined in the end use product.

*4. The GEM-V and GEM-H valve Series are intended to be mounted to a

suitable manifold. The need for external leakage and hydrostatic strength

tests should be reviewed on the end use product.

*5. The temperature test for the GEM-V valve Series was conducted

with a three position base plate manifold. If the number of valves is greater

than three on the manifold, consideration shall be given to conducting an

additional temperature test.

*6. The temperature test for the GEM-H valve Series was conducted

while mounted to a single position aluminum baseplate manifold with dimensions

of 1-3/8 by 1-1/4 by 5/8 in. If the number of valve positions on the manifold

is greater than one consideration shall be given to conducting an additional

temperature test is necessary on the end use product.

7. The suitability of No. 20 AWG flying leads shall be determined in

the end-use application.

TEST TO BE CONDUCTED BY THE MANUFACTURER:

Each valve shall be subjected to an operation test at the maximum rated

pressure differential.

*MARKINGS:

The Recognized Company's name or trademark, and electrical rating in

volts, Hz, and watts appear on a pressure sensitive label affixed to the coil.

See ILL. A for details. The catalog number appears on a separate pressure

sensitive label attached to the valve body.

Page 22: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 4 Issued: 1985-03-053

and Report Revised: 2013-03-01

CONSTRUCTION DETAILS:

*SERIES GEM-A, GEM-V AND GEM-H VALVES -FIG. 1 (K85-719)

Note – Some Cat. No’s are shown containing X as part of their

nomenclature. For these examples, the “X” is used to represent any viable

number or letter that is consistent with the nomenclature for that part.

*1. Assembled Valve - Cat. No. GEM-H-13XXX-XXX shown. See ILL. 1 for cross

sectional view. See Fig. 2 for details.

*2. Assembled Valves - Cat. Nos. GEM-V-XX1XX36XX-X3X shown attached to a 3

position baseplate manifold. See ILL. 2 and 3 for cross sectional view

for the normally closed and normally open versions. See Fig. 3 for

details.

*3. Assembled Valve - Cat. No. GEM-A-XX146XX-X3X shown. See ILL. 4 and 5

for cross sectional view of the normally closed and normally opened

versions. See Fig. 4 for details.

Page 23: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 5 Issued: 1985-03-053

and Report Revised: 2013-03-01

*DETAILS, SERIES GEM-H VALVES - FIG. 2 (K85-724)

1. Retainer - Steel, 0.56 mm (0.022 in.) thick, 18.8 mm (0.741 in.) across

the flats. Center is stamped to follow external threads on top of

guide to assembly, Item 3.

2. Coil Assembly - Class 105(A) insulation system random wound enameled

copper wire. Encapsulated coil dimensions are 41 by 33 by 31.0 mm

(1.61 by 1.30 by 1.22 in.) provided with a 13.2 mm (0.52 in.) hole for

the guide tube assembly, Item 3. Assembly consists of the following:

Coil Voltage/ Winding

Suffix Frequency Wattage Resistance, ohms Winding Wire, mm OD

20 12 dc 10 14.5 0.315

30 24 dc 10 56.3 0.224

35 24/50 9 9.3 0.355

36 24/60 9 7.6 0.355

45 48/50 9 40 0.24

55 110/50 9 228 0.24

56 120/60 9 195 0.16

56L 120/60 9 195 0.16

95 230/50 9 1195 0.1

96 230/60 9 850 0.112

97 220/50/60 9 850 0.112

A. Bobbin - Molded polyester resin, 0.8 mm (0.032 in.) minimum

thickness, 13.2 mm (0.520 in.) ID. Ends form insulation and are

25 mm (1.20 in.) square and at least 0.7 mm (0.028 in.) thick.

B. Cross Over Insulation - Provided with 0.075 mm (0.003 in.) thick

pressure sensitive plastic tape, holding start wire against

inside bobbin end. Tape extends beyond the outer windings of the

coil.

C. Coil Housing - Plated steel, see ILL. 6 for details. See ILL. 6A

for alternate.

D. Encapsulation - Molded polyester resin, at least 0.8 mm

(0.032 in.) thick.

*E. Terminals - Plated brass spade type, formed as shown. See ILL. 7

and 8 for details. See ILL. 7A, 8A, and 8B for alternate.

Alternate - R/C (AVLV2), No. 20 AWG minimum soldered to above

spade terminals. Rated 300 V minimum.

Page 24: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 7 Issued: 1985-03-053

and Report Revised: 2013-03-01

*DETAILS, SERIES GEM-V VALVES - FIG. 3 (K85-722)

1. Retainer - Same as Item 1, Fig. 2.

2. Coil Assembly - Same as Item 2, Fig. 2.

3. Guide Tube Assembly - Same as Item 3, Fig. 2.

4. Plunger Assembly - Same as Item 4, Fig. 2, except for normally open

valves, spring free length is 9.04 mm (0.356 in.).

5. Manual Override - Brass, see ILL. 11 for details. Provided with a

synthetic rubber O-ring 3.69 mm (0.145 in.) ID by 1.78 mm (0.070 in.)

cross-sectional diameter.

6. Body - Painted aluminum alloy, see ILL. 12 for details. Provided with

brass insert orifice and two synthetic rubber O-rings in the inlet and

outlet ports. O-rings are 6.2 mm (0.244 in.) OD by 1.1 mm (0.043 in.)

cross-sectional diameter.

Alternate - Mazak, brass or stainless steel.

7. Baseplate Manifold - (Optional) - Painted aluminum alloy, 98.0 mm

(3.86 in.), by 34.8 mm (1.37 in.) by 15.8 mm (0.622 in.). Length

varies depending upon the number of stations from 2 to 6. Dimension

given is for 3 stations.

Page 25: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AFF:str NKDLS

File MH12494 Vol. 1 Sec. 1 Page 8 Issued: 1985-03-053

and Report Revised: 2013-03-01

*DETAILS, SERIES GEM-A VALVES -FIG. 4 (K85-721)

1. Retainer - Same as Item 1, Fig. 2.

2. Coil Assembly - Same as Item 2, Fig. 2.

3. Guide Tube Assembly - Same as Item 3, Fig. 2.

4. Plunger Assembly - Same as Item 4, Fig. 2, except for normally open

valves, spring length is 9.04 mm (0.356 in.).

5. Manual Override - Same as Item 5, Fig. 3.

*6. Body - Painted aluminum. See ILL. 13 for details. Provided with brass

insert orifice.

Alternate - Mazak, brass or stainless steel.

Page 26: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 FIG-1 Issued: 1985-03-05

And Report Revised: 2013-03-01

K8500719.P00

Page 27: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 FIG-2 Issued: 1985-03-05

And Report Revised: 2013-03-01

K8500724.P00

Page 28: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 FIG-3 Issued: 1985-03-05

And Report Revised: 2013-03-01

K8500722.P00

Page 29: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 FIG-4 Issued: 1985-03-05

And Report Revised: 2013-03-01

K8500721.P00

Page 30: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-1 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232609

Page 31: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-2 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232610

Page 32: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-3 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232611

Page 33: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-4 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232612

Page 34: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-5 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232613

Page 35: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-6A Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232615

Page 36: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-7A Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232617

Page 37: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-8A Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232619

Page 38: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-8B Issued: 1985-03-05

And Report New: 2013-03-01

N130984489

Page 39: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-9 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232620

Page 40: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-10 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232621

Page 41: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-11 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232622

Page 42: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-12 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232623

Page 43: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-13 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232624

Page 44: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-14 Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232625

Page 45: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 1 ILL-A Issued: 1985-03-05

And Report Revised: 2013-03-01

N050232626

Page 46: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

RJJ/AEE:str NKDLS

File MH12494 Page T4-1 of 1 Issued: 1985-03-05

New: 2013-03-01

TEST RECORD NO. 4

SAMPLES:

Samples of the general purpose valves, Series 3000, 5000, 7000, and 9000

were submitted by the applicant to receive a new Product Numbering system

(nomenclature). This new nomenclature changes the Series 3000 and 5000 into

the new Series GEM-A; the Series 7000 into the new Series GEM-V; and the

Series 9000 into the Series GEM-H. Additionally, drawings were to be updated

to their latest revisions.

General:

Since the new drawings did not change any critical dimensions or

features and the changes to the file were editorial in nature only, no testing

was considered necessary based on engineering judgment that valve performance

is not affected by these changes.

TEST RECORD SUMMARY:

The results of this investigation, including construction review and

testing, indicate that the product(s) evaluated comply with the applicable

requirements in the Standard for Electrically Operated Valves, UL 429, Fifth

Edition (Revised December 12, 2008) and therefore, such products are judged

eligible to bear UL’s Mark as described on the Conclusion Page of this Report.

Any information and documentation involving UL Mark services are provided on

behalf of UL LLC (UL) or any authorized licensee of UL.

Test Record by: Reviewed by:

Scott Crary Alberto Gomez

Engineer Senior Project Engineer

Page 47: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494

Project 84NK22873

Issued: March 6, 1985

Revised: March 1, 2013

REPORT

on

COMPONENT - ELECTRICALLY OPERATED VALVES

*Baccara Geva Agriculture Corporation Society LTD.

Kvutzat Geya, Israel

Copyright © 1985 Underwriters Laboratories Inc.

Underwriters Laboratories Inc. authorizes the above named company to

reproduce this Report provided it is reproduced in its entirety.

*Underwriters Laboratories Inc. authorizes the above named company to

reproduce that portion of this Report consisting of this Cover Page

through Page 3.

Page 48: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 Page 1 Issued: 1985-03-063

and Report Revised: 2013-03-01

PRODUCT COVERED:

*

USR - General Purpose Valve, Cat. No. GEM-S, followed by 2, followed by

21, 31, or 41, followed by 1 or 2, followed by N, V, or E, followed by 0

or 2, followed by 2, 3, 4, 5, 6, or 7, followed by 1, 2, or 3, followed

by 0 or 4.

GENERAL:

These are pilot operated piston, two way valves of both normally open

and normally closed types, intended to control water or air.

*

GLOSSARY:

R/C - Recognized Component.

USR - Investigated to UL 429.

DESCRIPTION _ _ _ _ _ _ _ _ _ _

Page 49: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 Page 1A Issued: 1985-03-06

and Report New: 2013-03-01

NOMENCLATURE:

Cat No.

A. Designates Basic Family of Valves

Always “GEM-S”

B. Designates Valve Body Material

2 – Brass

C. Designates Port Type and Size

21 – 1/4” NPT

31 – 3/8” NPT

41 – 1/2” NPT

D. Designates Valve Type

1 – 2 Way Normally Closed

2 – 2 Way Normally Open

E. Designates Seal Material

N – NBR

V – Viton

E – EPDM

F. Designates Manual Override

0 – None

2 - Slot

G. Designates Voltage Rating

2 – 12 Volts

3 – 24 Volts

4 – 48 Volts

5 – 110 Volts

6 – 120 Volts

7 – 230 Volts

H. Designates Power and Frequency rating

1 – AC, 50 Hz, 8 Watts

2 – AC, 50 HZ, 8 Watts

3 – DC, 10 Watts

I. Designates Connector Type

0 - None

4 – Flying leads

GEM-S - 2 20 1 N 0 - 1 3 1

A B C D E F G H I

Page 50: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 Page 2 Issued: 1985-03-063

and Report Revised: 2013-03-01

RATINGS:

Ambient Temperature: +50°C

Fluid Temperature: +70°C

Fluid Types: Air and water

Maximum Body Pressure: 176.4 psi

Maximum Operating Pressure Differential: 176.4 psi

Electrical Rating:

Potential

(Volts)

Frequency

(Hz)

Power

(Watts)

12 50/60 8

24 50/60 8

48 50/60 8

110 50/60 8

120 50/60 8

230 50/60 8

12 DC 10

24 DC 10

*

Basic Catalog Orifice Size

Designation__ Valve Type mm (in.) Inlet and Outlet Sizes, NPT

*GEM-S-2211XX-XXX Normally Closed 8.0 (0.315) 1/4

*GEM-S-2212XX-XXX Normally Open 8.0 (0.315) 1/4

*GEM-S-2311XX-XXX Normally Closed 8.0 (0.315) 3/8

*GEM-S-2312XX-XXX Normally Open 8.0 (0.315) 3/8

*GEM-S-2411XX-XXX Normally Closed 12.0 (0.473) 1/2

*GEM-S-2412XX-XXX Normally Open 12.0 (0.473) 1/2

Page 51: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 Page 3 Issued: 1985-03-06

and Report Revised: 2013-03-01

TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE:

Use - For use only in products where the acceptability of the

combination is determined by UL LLC.

USR – Indicates investigation to UL Standard for Electrically Operated

Valves, UL 429, Fifth Edition.

Conditions of Acceptability:

1. These valves are for use within other equipment which provide

adequate electrical enclosure.

2. The attachment of leads to the terminals shall comply with the

requirements regarding secureness applicable to the class of equipment

involved. The terminals are not intended for field wiring.

3. The suitability of grounding connections of dead metal parts shall

be determined in the end use product.

TEST TO BE CONDUCTED BY THE MANUFACTURER:

Each valve shall be subjected to an operation test at the maximum rated

pressure differential.

MARKING:

* The Recognized Company’s name or trademark, and electrical rating in

volts, Hz, and watts appear on a pressure sensitive label affixed to the coil,

see ILL. A for details. The catalog number appears on a separate pressure

sensitive label attached to the valve body.

*

Page 52: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 Page 4 Issued: 1985-03-063

and Report Revised: 2013-03-01

CONSTRUCTION DETAILS:

*

SERIES GEM-S VALVES - FIG. 1

1. Assembled Normally Closed Valve - Cat. No. GEM-S-2311XX-XXX shown,

represents all valve series. See ILL. 1 for cross-sectional view. See

Fig. 2, for details.

2. Assembled Normally Opened Valve - Cat. No. GEM-S-X412XX-XXX as shown,

represents all valve series. See ILL. 2 for cross-sectional view. See

Fig. 3, for details.

Page 53: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 Page 5 Issued: 1985-03-063

and Report Revised: 2013-03-01

*DETAILS, NORMALLY CLOSED TYPES - FIG. 2

1. Retainer - Steel, 0.56 mm (0.022 in.) thick. 18.8 mm (0.741 in.) across

the flats. Center is stamped to follow external threads on top of guide

to assembly, Item 3.

2. *Coil Assembly - Class A insulation system random wound enameled copper

wire. Encapsulated coil dimensions are 41 by 33 by 31.0 mm (1.61 by

1.30 by 1.22 in.) provided with a 13.2 mm (0.52 in.) hole for the guide

tube assembly, Item 3. Assembly consists of the following:

*Bobbin - Molded polyester resin, 0.8 mm (0.032 in.) minimum thickness,

13.2 mm (0.520 in.) ID. Ends form insulation and are 25 mm (1.20 in.)

square and at least 0.7 mm (0.28 in.) thick.

Cross Over Insulation - Provided with 0.076 mm (0.003 in.) thick

pressure sensitive plastic tape, holding start wire against inside

bobbin end. Tape extends beyond the outer windings of the coil.

*Coil Housing - Plated steel, see ILL. 3 for details.

Encapsulation - Molded polyester resin, at least 0.8 mm (0.032 in.)

thick.

*Terminals - Plated brass, formed as shown, see ILL. 4, 5, and 5A for

details.

*3. Plunger Assembly - Stainless steel, see ILL. 6 for details.

Provided with two synthetic rubber disks. Seat is spring loaded and

captivated, bottom seat is mechanically secured and captivated. Spring

is also provided and is stainless steel, 0.9 mm (0.035 in.) wire

diameter. Spring has of 13.6 mm (0.535 in.) OD tappering to 10 mm

(0.394 in.) OD, free length is 13.0 mm (0.512 in.).

*4. Guide Tube Assembly - Stainless steel, overall dimensions 13.0 mm

(0.511 in.) diameter by 54.7 mm (2.15 in.) long, 0.75 mm (0.030 in.)

minimum wall thickness. Top end provided with external 1/4 in. BSP

thread. Other end provided with body nut. Synthetic rubber gasket

18 mm (0.0709 in.) ID by 1.5 mm (0.059 in.) cross section diameter,

provided as shown.

Page 54: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 Page 6 Issued: 1985-03-063

and Report Revised: 2013-03-01

5.* Manual Override Pin - Brass, see ILL. 7 for details. Provided with a

synthetic rubber O-ring, 4.47 mm (0.176 in.) ID by 1.78 mm (0.070 in.)

cross-sectional diameter and stainless steel spring, 7.4 mm (0.291 in.)

OD, by 15 mm (0.591 in.) free length (not shown).

6*. Upper Body - Brass, see ILL. 8 for GEM-S-2211XX-XXX and GEM-S-2311XX-XXX

valve series, and ILL. 9 for GEM-S-2411XX-XXX valve Series. Provided

with a synthetic rubber O-ring, 7 mm (0.276 in.) ID for Models GEM-S-

2211XX-XXX and GEM-S-2311XX-XXX, 5 mm (0.197 in.) ID for Model GEM-S-

2411XX-XXX valves; both with 1.5 mm (0.059 in.) cross-section.

*7. Mounting Bolts - Plated steel, socket heat screw, 14 mm (0.550 in.)

long. Four provided as shown.

8. Diaphgram Assembly - Assembly consists of the following:

*Diaphgram - Synthetic rubber, approx 28 mm (1.10 in.) OD by 1.5 mm

(0.059 in.) thick for GEM-S-2211XX-XXX and GEM-S-2311XX-XXX valve

series, and 34.7 mm (1.37 in.) OD by 2.0 mm (0.079 in.) thick for GEM-S-

2411XX-XXX valve series.

*Holder - Brass, see ILL. 10 for GEM-S-2211XX-XXX, and GEM-S-2311XX-XXX

valve series, and ILL. 11 for GEM-S-2411XX valve series.

*Spring - Stainless steel, 0.4 mm (0.016 in.) wire diameter, 3.9 mm

(0.154 in.) OD by 11 mm (0.433 in.) free length for 1720 and 2720 valve

series, and 1.5 mm (0.059 in.) wire diameter, 3.8 mm (0.150 in.) OD by

11.8 mm (0.465 in.) free length for 4730 valve series.

9. Lower Body - Brass, see ILL. 12, 13 and 14 for details on the GEM-S-

2211XX-XXX, GEM-S-2311XX-XXX, and GEM-S-2411XX-XXX valve series

respectively.

Page 55: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 Page 7 Issued: 1985-03-063

and Report Revised: 2013-03-01

*DETAILS, NORMALLY OPEN VALVES - FIG. 3

General - Similar to the normally closed valves, for items not

referenced see Fig. 3.

1.* Guide Tube Assembly - Stainless steel, overall dimensions 13.0 mm

(0.511 in.) diameter by 54.7 mm (2.15 in.) long, 0.75 mm (0.030 in.)

minimum wall thickness. Top end provided with external 1/4 in. BSP

thread and internal 1/8 in. NPT thread. Other end provided with body

nut as shown. Synthetic rubber gasket, 18 mm (0.709 in.) ID by 1.5 mm

(0.059 in.) cross section diameter, provided as shown.

2. *Pilot Tube Adaptor - Brass, 18.4 mm (0.725 in.) long. One end provided

with 1/8 in. NPT thread for guide tube assembly top, Item 1. Other end

provided with female thread for pilot tube assembly, Item 3.

3. Pilot Tube Assembly - Consists of the following:

*Tube - Plastic, formed as shown, 4.75 mm (0.187 in.) OD by 95.8 mm

(3.77 in.) assembled length. Minimum wall thickness, 0.79 mm

(0.031 in.).

Fittings - Brass, two provided for female threads in guide tube

assembly, Item 1 and upper body, Item 4.

Compression Ring - Brass, two provided.

4. * Upper Body - Brass, see ILL. 15 for GEM-S-2212XX-XXX and GEM-S-

2311XX-XXX valve series, ILL. 16 for GEM-S-2412XX-XXX valve series.

GEM-S-2212XX-XXX and GEM-S-2311XX-XXX are provided with synthetic rubber

O-ring, 7 mm (0.276 in.) ID by 1.5 mm (0.059 in.) cross-section. GEM-S-

2412XX-XXX is provided with a synthetic rubber O-ring 5 mm (0.138 in.)

ID by 1.5 mm (0.059 in.) cross-sectional area.

Page 56: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20130305-MH12494

Report Reference MH12494-19850306

Issue Date 2013-MARCH-05

William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus

Page 1 of 2

Issued to: BACCARA GEVA AGRICULTURE CORPORATION

SOCIETY LTD

KIBBUTZ GEVA

18915 KVUTZAT GEVA ISRAEL

This is to certify that

representative samples of

COMPONENT - VALVES, ELECTRICALLY OPERATED

See next page

Have been investigated by UL in accordance with the

Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 429 STANDARD FOR ELECTRICALLY OPERATED VALVES

Additional Information: See the UL Online Certifications Directory at

www.ul.com/database for additional information

Only those products bearing the UL Recognized Component Mark should be considered as being covered by UL's Recognition and Follow-Up Service.

The UL Recognized Component Mark generally consists of the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory. As a supplementary means of identifying products that have been produced under UL’s Component Recognition Program, UL’s Recognized Component Mark: , may be used in conjunction with the required Recognized Marks. The Recognized Component Mark is required when specified in the UL Directory preceding the recognitions or under “Markings” for the individual recognitions.

Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC. Look for the UL Recognized Component Mark on the product.

Page 57: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20130305-MH12494

Report Reference MH12494-19850306

Issue Date 2013-MARCH-05

William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus

Page 2 of 2

General Purpose Valve, Cat. No. GEM-S, followed by 2, followed by 21, 31, or 41, followed by 1 or 2, followed by N, V, or E, followed by 0 or 2, followed by 2, 3, 4, 5, 6, or 7, followed by 1, 2, or 3, followed by 0 or 4.

Page 58: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 FIG-1 Issued: 1985-03-06

And Report Revised: 2013-03-01

K8500720.P00

Page 59: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 FIG-2 Issued: 1985-03-06

And Report Revised: 2013-03-01

K8500723.P00

Page 60: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 FIG-3 Issued: 1985-03-06

And Report Revised: 2013-03-01

K8500725.P00

Page 61: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-1 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232592

Page 62: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-2 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232593

Page 63: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-3 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232594

Page 64: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-4 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232595

Page 65: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-5 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232596

Page 66: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-5A Issued: 1985-03-06

And Report New: 2013-03-01

N130984531

Page 67: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-6 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232597

Page 68: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-7 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232598

Page 69: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-8 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232599

Page 70: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-9 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232600

Page 71: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-10 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232601

Page 72: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-11 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232602

Page 73: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-12 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232603

Page 74: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-13 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232604

Page 75: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-14 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232605

Page 76: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-15 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232606

Page 77: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-16 Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232607

Page 78: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Vol. 1 Sec. 2 ILL-A Issued: 1985-03-06

And Report Revised: 2013-03-01

N050232608

Page 79: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Page T2-1 of Issued: 1986-03-06

New: 2013-03-01

TEST RECORD NO. 2 SAMPLES: Samples of the general purpose valves, Series 1000, 2000, and 4000 were submitted by the applicant to receive a new Product Numbering system (nomenclature). This new nomenclature combines the Series 1000, 2000, and 4000 into new Series GEM-S. Additionally, drawings were to be updated to their latest revisions. General:

Since the new drawings did not change any critical dimensions or features and the changes to the file were editorial in nature only, no testing was considered necessary based on engineering judgment that valve performance is not affected by these changes. TEST RECORD SUMMARY: The results of this investigation, including construction review and testing, indicate that the product(s) evaluated comply with the applicable requirements in the Standard for Electrically Operated Valves, UL 429, Fifth Edition (Revised December 12, 2008) and therefore, such products are judged eligible to bear

UL’s Mark as described on the Conclusion Page of this Report. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Test Record by: Reviewed by: Scott Crary Alberto Gomez Engineer Senior Project Engineer

Page 80: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

File MH12494 Page C1 Issued: 1986-03-06

Revised: 2013-03-01

*CONCLUSION

Samples of the component covered by this Report have been found to

comply with the requirements covering the category and the component is found

to comply with UL’s applicable requirements. The description and test result

in this Report are only applicable to the sample(s) investigated by UL and

does not signify UL certification or that the product(s) described are covered

under UL’s Follow-Up Service Program. When covered under UL’s Follow-Up

Service Program, the manufacturer is authorized to use the Recognized Marking

on such products which comply with UL’s Follow-Up Service Procedure and any

other applicable requirements of UL LLC. The Recognized Component Mark of UL

LLC on the product, or the Recognized Marking symbol on the product and the

Recognized Component Mark on the smallest unit container in which the product

is packaged, is the only method to identify products investigated by UL to

published requirements and manufactured under UL’s Recognition and Follow-Up

Service.

This Report is intended solely for the use of UL and the Applicant for

establishment of UL certification coverage of the product under UL’s Follow-Up

Service. UL retains all rights, title and interest (including exclusive

ownership) in this Report and all copyright therein. Unless expressly

authorized in writing by UL, the Applicant shall not disclose or otherwise

distribute this Report or its contents to any third party or use this Report

for any purpose other than to establish UL certification and become eligible

for Follow-Up Service for the product(s) described in this Report. Any other

use of this Report including without limitation, evaluation or certification

by a party other than UL unless part of a certification scheme, is prohibited

and renders the Report null and void. UL shall not incur any obligation or

liability for any loss, expense, or punitive damages, arising out of or in

connection with the use or reliance upon the contents of this Report to anyone

other than the Applicant as provided in the agreement between UL and

Applicant. Any use or reference to UL’s name or certification mark(s) by

anyone other than the Applicant in accordance with the agreement is prohibited

without the express written approval of UL. Any information and documentation

provided to you involving UL Mark services are provided on behalf of UL LLC

(UL) or any authorized licensee of UL. UL shall not otherwise be responsible

to anyone for the use of or reliance upon the contents of this Report.

Report by: Reviewed by:

MARSHALL ISSEN T. A. HILLENBRAND

Associate Project Engineer Senior Project Engineer

Casualty and Chemical Casualty and Chemical

Hazards Department Hazards Department

Page 81: IECEx Quality Assessment Report QAR Free Reference No.: … · 2016-05-25 · Scope of Audit: Initial Assessment Reassessment Surveillance Revision Audit of Product Quality Plans

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20130305-MH12494

Report Reference MH12494-19850306

Issue Date 2013-MARCH-05

William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus

Page 2 of 2

General Purpose Valve, Cat. No. GEM-S, followed by 2, followed by 21, 31, or 41, followed by 1 or 2, followed by N, V, or E, followed by 0 or 2, followed by 2, 3, 4, 5, 6, or 7, followed by 1, 2, or 3, followed by 0 or 4.