Task 47 Workshop: Renovation of Non- Residential Buildings towards Sustainable Solutions, Sydney 05.04.13 Lighting standards in renovated buildings Roman Alexander Jakobiak [email protected]

Upload: others

Post on 12-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

2 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

bull Energy efficient lighting

ndash Energy efficient fixtures additional blackboard lighting

bull Light for better learning

ndash Possibility to shift color temperature to bluish and to increase lighting level

beyond standard requirements additional blackboard lighting

raquo daylight responsive controls and occupancy sensors for ambient lighting

ambient lighting

4 x Trilux 5041 (RPX-L354980 EDD)

equipped with 1 x 35 W T16

and dimmable electronic ballast

blackboard lighting

2 x Trilux 5041 (RAV-L354980 E)

equipped with 1 x 80 W T16

and electronic ballast

4 x Trilux Valuco active

equipped with 1 x 35 W T16 for ambient

lighting and 2 x 49 W T16 for activating

light dimmable electronic ballast

blackboard lighting

2 x Trilux 5041 (RAV-L354980 E)

equipped with 1 x 80 W T16

and electronic ballast

Lighting retrofit in selected classrooms of

Koumlnigin-Luise-Schule Berlin

Pictures of luminaires

Trilux (wwwtriluxcom)

This lighting renovation was part of a research

project of TU-Berlin IBUS and Chariteacute with Trilux

3 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom 120 Energy efficient lighting

Classroom 120 before renovation Classroom 120 after renovation

4 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

profile of usage classroom (schools) after renovation before Reference

total blackboard working plane working plane EnEV 2009

installed power density pj 99 Wmsup2 53 Wmsup2 47 Wmsup2 138 Wmsup2 92 Wmsup2

expenditure figure for electric lighting system elK - - 153 453 315

gross window area ARB 623 msup2 623 msup2 623 msup2 623 msup2 623 msup2

area of daylighting zone ATL 2987 msup2 2987 msup2 2987 msup2 2987 msup2 2987 msup2

area of electric lighting zone AKTL 251 msup2 251 msup2 251 msup2 251 msup2 251 msup2

daylight factor for structure DRb 34 34 34 34 34

classification of daylight level - poor poor poor poor poor

factor daylight contribution (without shading) CTLVersSNA 070 070 070 070 067

factor daylight contribution (with shading) CTLVersSA 015 015 015 015 015

factor daylight contribution over all CTLVers 059 059 059 059 056

factor of daylight responsive controls CTLKon 063 05 0781 05 05

reduction factor for daylighting FTL 063 071 054 071 072

expenditure figure daylight elTLKon - - 126 159 154

factor of occupancy responsive controls CpraumlKon 071 050 095 050 050

reduction factor for occupancy FPrauml 082 088 076 088 088

expenditure figure - occupancy elPraumlsKon 110 117 102 117 117

reduction factor for maintenance FKL 095 100 090 100 090

expenditure figure - maintenance elPraumlsKon 106 111 100 111 100

eff operation time in daylighting zone (day) teffTagTL 701 h 863 h 518 h 863 h 790 h

eff operation time (night) teffNacht 2 h 2 h 1 h 2 h 2 h

eff operation time in el lighting zone (day) teffKTL 1099 h 1223 h 959 h 1223 h 1101 h

final energy use of building zone Qlbj 235 kWha 152 kWha 84 kWha 400 kWha 243 kWha

specific final energy use per squaremeter Qlbn 65 kWhmsup2a 42 kWhmsup2a 23 kWhmsup2a 111 kWhmsup2a 68 kWhmsup2a

expenditure figure for lighting el - - 196 934 566

Classroom 120 Energy efficient lighting

The calculation according to DIN V

18599-4 2011-12 includes no method

for lighting on a vertical plane

5 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom 14 Light for better learning

Classroom 14 before renovation Classroom 14 after renovation

6 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

profile of usage classroom (schools) after renovation before Reference

total blackboard working plane working plane EnEV 2009

installed power density pj 232 Wmsup2 53 Wmsup2 180 Wmsup2 87 Wmsup2 92 Wmsup2

expenditure figure for electric lighting system elK - - 554 268 315

gross window area ARB 595 msup2 595 msup2 595 msup2 595 msup2 595 msup2

area of daylighting zone ATL 3044 msup2 3044 msup2 3044 msup2 3044 msup2 3044 msup2

area of electric lighting zone AKTL 177 msup2 177 msup2 177 msup2 177 msup2 177 msup2

daylight factor for structure DRb 24 24 24 24 24

classification of daylight level - poor poor poor poor poor

factor daylight contribution (without shading) CTLVersSNA 055 055 055 055 052

factor daylight contribution (with shading) CTLVersSA 015 015 015 015 015

factor daylight contribution over all CTLVers 047 047 047 047 044

factor of daylight responsive controls CTLKon 072 05 078 05 05

reduction factor for daylighting FTL 066 077 063 077 078

expenditure figure daylight elTLKon - - 117 140 136

factor of occupancy responsive controls CpraumlKon 085 050 095 050 050

reduction factor for occupancy FPrauml 079 088 076 088 088

expenditure figure - occupancy elPraumlsKon 105 117 102 117 117

reduction factor for maintenance FKL 092 100 090 100 090

expenditure figure - maintenance elPraumlsKon 103 111 100 111 100

eff operation time in daylighting zone (day) teffTagTL 683 h 937 h 608 h 937 h 856 h

eff operation time (night) teffNacht 1 h 2 h 1 h 2 h 2 h

eff operation time in el lighting zone (day) teffKTL 1019 h 1223 h 959 h 1223 h 1101 h

final energy use of building zone Qlbj 526 kWha 162 kWha 364 kWha 267 kWha 258 kWha

specific final energy use per squaremeter Qlbn 147 kWhmsup2a 45 kWhmsup2a 102 kWhmsup2a 75 kWhmsup2a 72 kWhmsup2a

expenditure figure for lighting el - - 661 486 500

Classroom 14 Light for better learning

The calculation according to DIN V 18599-4

2011-12 includes no method for activating

light and for lighting on a vertical plane

7 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery Kassel

View from North West before renovation East faccedilade after renovation South faccedilade after renovation

Floor plan of exhibition level (Heinrich von Dehn-Rotfelser ca 1870 (Source Wikipedia)

1870 Design by Heinrich von Dehn-Rotfelser 1877 Opening 1943 Bomb damages 1962-1976 Reconstruction and

reopening 2007-2011 renovation designed by Staab-Architekten Berlin lighting consultant Licht Kunst Licht with Roman

Jakobiak daylightingde

8 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery hall with rooflight before refurbishment

9 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

New design 2007 - 2011 by Staab-Architekten (Source Staab-Architekten)

Original design 1871 -1877 by Heinrich von

Dehn-Rotfelser (Source Erbe 1923)

Prismatic glazing

Roller blinds

Electric lighting

Double glazing

Scattering plastic

10 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

Prismatic glazing

Scattering plastic

Double glazing

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 2: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

2 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

bull Energy efficient lighting

ndash Energy efficient fixtures additional blackboard lighting

bull Light for better learning

ndash Possibility to shift color temperature to bluish and to increase lighting level

beyond standard requirements additional blackboard lighting

raquo daylight responsive controls and occupancy sensors for ambient lighting

ambient lighting

4 x Trilux 5041 (RPX-L354980 EDD)

equipped with 1 x 35 W T16

and dimmable electronic ballast

blackboard lighting

2 x Trilux 5041 (RAV-L354980 E)

equipped with 1 x 80 W T16

and electronic ballast

4 x Trilux Valuco active

equipped with 1 x 35 W T16 for ambient

lighting and 2 x 49 W T16 for activating

light dimmable electronic ballast

blackboard lighting

2 x Trilux 5041 (RAV-L354980 E)

equipped with 1 x 80 W T16

and electronic ballast

Lighting retrofit in selected classrooms of

Koumlnigin-Luise-Schule Berlin

Pictures of luminaires

Trilux (wwwtriluxcom)

This lighting renovation was part of a research

project of TU-Berlin IBUS and Chariteacute with Trilux

3 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom 120 Energy efficient lighting

Classroom 120 before renovation Classroom 120 after renovation

4 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

profile of usage classroom (schools) after renovation before Reference

total blackboard working plane working plane EnEV 2009

installed power density pj 99 Wmsup2 53 Wmsup2 47 Wmsup2 138 Wmsup2 92 Wmsup2

expenditure figure for electric lighting system elK - - 153 453 315

gross window area ARB 623 msup2 623 msup2 623 msup2 623 msup2 623 msup2

area of daylighting zone ATL 2987 msup2 2987 msup2 2987 msup2 2987 msup2 2987 msup2

area of electric lighting zone AKTL 251 msup2 251 msup2 251 msup2 251 msup2 251 msup2

daylight factor for structure DRb 34 34 34 34 34

classification of daylight level - poor poor poor poor poor

factor daylight contribution (without shading) CTLVersSNA 070 070 070 070 067

factor daylight contribution (with shading) CTLVersSA 015 015 015 015 015

factor daylight contribution over all CTLVers 059 059 059 059 056

factor of daylight responsive controls CTLKon 063 05 0781 05 05

reduction factor for daylighting FTL 063 071 054 071 072

expenditure figure daylight elTLKon - - 126 159 154

factor of occupancy responsive controls CpraumlKon 071 050 095 050 050

reduction factor for occupancy FPrauml 082 088 076 088 088

expenditure figure - occupancy elPraumlsKon 110 117 102 117 117

reduction factor for maintenance FKL 095 100 090 100 090

expenditure figure - maintenance elPraumlsKon 106 111 100 111 100

eff operation time in daylighting zone (day) teffTagTL 701 h 863 h 518 h 863 h 790 h

eff operation time (night) teffNacht 2 h 2 h 1 h 2 h 2 h

eff operation time in el lighting zone (day) teffKTL 1099 h 1223 h 959 h 1223 h 1101 h

final energy use of building zone Qlbj 235 kWha 152 kWha 84 kWha 400 kWha 243 kWha

specific final energy use per squaremeter Qlbn 65 kWhmsup2a 42 kWhmsup2a 23 kWhmsup2a 111 kWhmsup2a 68 kWhmsup2a

expenditure figure for lighting el - - 196 934 566

Classroom 120 Energy efficient lighting

The calculation according to DIN V

18599-4 2011-12 includes no method

for lighting on a vertical plane

5 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom 14 Light for better learning

Classroom 14 before renovation Classroom 14 after renovation

6 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

profile of usage classroom (schools) after renovation before Reference

total blackboard working plane working plane EnEV 2009

installed power density pj 232 Wmsup2 53 Wmsup2 180 Wmsup2 87 Wmsup2 92 Wmsup2

expenditure figure for electric lighting system elK - - 554 268 315

gross window area ARB 595 msup2 595 msup2 595 msup2 595 msup2 595 msup2

area of daylighting zone ATL 3044 msup2 3044 msup2 3044 msup2 3044 msup2 3044 msup2

area of electric lighting zone AKTL 177 msup2 177 msup2 177 msup2 177 msup2 177 msup2

daylight factor for structure DRb 24 24 24 24 24

classification of daylight level - poor poor poor poor poor

factor daylight contribution (without shading) CTLVersSNA 055 055 055 055 052

factor daylight contribution (with shading) CTLVersSA 015 015 015 015 015

factor daylight contribution over all CTLVers 047 047 047 047 044

factor of daylight responsive controls CTLKon 072 05 078 05 05

reduction factor for daylighting FTL 066 077 063 077 078

expenditure figure daylight elTLKon - - 117 140 136

factor of occupancy responsive controls CpraumlKon 085 050 095 050 050

reduction factor for occupancy FPrauml 079 088 076 088 088

expenditure figure - occupancy elPraumlsKon 105 117 102 117 117

reduction factor for maintenance FKL 092 100 090 100 090

expenditure figure - maintenance elPraumlsKon 103 111 100 111 100

eff operation time in daylighting zone (day) teffTagTL 683 h 937 h 608 h 937 h 856 h

eff operation time (night) teffNacht 1 h 2 h 1 h 2 h 2 h

eff operation time in el lighting zone (day) teffKTL 1019 h 1223 h 959 h 1223 h 1101 h

final energy use of building zone Qlbj 526 kWha 162 kWha 364 kWha 267 kWha 258 kWha

specific final energy use per squaremeter Qlbn 147 kWhmsup2a 45 kWhmsup2a 102 kWhmsup2a 75 kWhmsup2a 72 kWhmsup2a

expenditure figure for lighting el - - 661 486 500

Classroom 14 Light for better learning

The calculation according to DIN V 18599-4

2011-12 includes no method for activating

light and for lighting on a vertical plane

7 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery Kassel

View from North West before renovation East faccedilade after renovation South faccedilade after renovation

Floor plan of exhibition level (Heinrich von Dehn-Rotfelser ca 1870 (Source Wikipedia)

1870 Design by Heinrich von Dehn-Rotfelser 1877 Opening 1943 Bomb damages 1962-1976 Reconstruction and

reopening 2007-2011 renovation designed by Staab-Architekten Berlin lighting consultant Licht Kunst Licht with Roman

Jakobiak daylightingde

8 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery hall with rooflight before refurbishment

9 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

New design 2007 - 2011 by Staab-Architekten (Source Staab-Architekten)

Original design 1871 -1877 by Heinrich von

Dehn-Rotfelser (Source Erbe 1923)

Prismatic glazing

Roller blinds

Electric lighting

Double glazing

Scattering plastic

10 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

Prismatic glazing

Scattering plastic

Double glazing

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 3: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

3 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom 120 Energy efficient lighting

Classroom 120 before renovation Classroom 120 after renovation

4 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

profile of usage classroom (schools) after renovation before Reference

total blackboard working plane working plane EnEV 2009

installed power density pj 99 Wmsup2 53 Wmsup2 47 Wmsup2 138 Wmsup2 92 Wmsup2

expenditure figure for electric lighting system elK - - 153 453 315

gross window area ARB 623 msup2 623 msup2 623 msup2 623 msup2 623 msup2

area of daylighting zone ATL 2987 msup2 2987 msup2 2987 msup2 2987 msup2 2987 msup2

area of electric lighting zone AKTL 251 msup2 251 msup2 251 msup2 251 msup2 251 msup2

daylight factor for structure DRb 34 34 34 34 34

classification of daylight level - poor poor poor poor poor

factor daylight contribution (without shading) CTLVersSNA 070 070 070 070 067

factor daylight contribution (with shading) CTLVersSA 015 015 015 015 015

factor daylight contribution over all CTLVers 059 059 059 059 056

factor of daylight responsive controls CTLKon 063 05 0781 05 05

reduction factor for daylighting FTL 063 071 054 071 072

expenditure figure daylight elTLKon - - 126 159 154

factor of occupancy responsive controls CpraumlKon 071 050 095 050 050

reduction factor for occupancy FPrauml 082 088 076 088 088

expenditure figure - occupancy elPraumlsKon 110 117 102 117 117

reduction factor for maintenance FKL 095 100 090 100 090

expenditure figure - maintenance elPraumlsKon 106 111 100 111 100

eff operation time in daylighting zone (day) teffTagTL 701 h 863 h 518 h 863 h 790 h

eff operation time (night) teffNacht 2 h 2 h 1 h 2 h 2 h

eff operation time in el lighting zone (day) teffKTL 1099 h 1223 h 959 h 1223 h 1101 h

final energy use of building zone Qlbj 235 kWha 152 kWha 84 kWha 400 kWha 243 kWha

specific final energy use per squaremeter Qlbn 65 kWhmsup2a 42 kWhmsup2a 23 kWhmsup2a 111 kWhmsup2a 68 kWhmsup2a

expenditure figure for lighting el - - 196 934 566

Classroom 120 Energy efficient lighting

The calculation according to DIN V

18599-4 2011-12 includes no method

for lighting on a vertical plane

5 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom 14 Light for better learning

Classroom 14 before renovation Classroom 14 after renovation

6 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

profile of usage classroom (schools) after renovation before Reference

total blackboard working plane working plane EnEV 2009

installed power density pj 232 Wmsup2 53 Wmsup2 180 Wmsup2 87 Wmsup2 92 Wmsup2

expenditure figure for electric lighting system elK - - 554 268 315

gross window area ARB 595 msup2 595 msup2 595 msup2 595 msup2 595 msup2

area of daylighting zone ATL 3044 msup2 3044 msup2 3044 msup2 3044 msup2 3044 msup2

area of electric lighting zone AKTL 177 msup2 177 msup2 177 msup2 177 msup2 177 msup2

daylight factor for structure DRb 24 24 24 24 24

classification of daylight level - poor poor poor poor poor

factor daylight contribution (without shading) CTLVersSNA 055 055 055 055 052

factor daylight contribution (with shading) CTLVersSA 015 015 015 015 015

factor daylight contribution over all CTLVers 047 047 047 047 044

factor of daylight responsive controls CTLKon 072 05 078 05 05

reduction factor for daylighting FTL 066 077 063 077 078

expenditure figure daylight elTLKon - - 117 140 136

factor of occupancy responsive controls CpraumlKon 085 050 095 050 050

reduction factor for occupancy FPrauml 079 088 076 088 088

expenditure figure - occupancy elPraumlsKon 105 117 102 117 117

reduction factor for maintenance FKL 092 100 090 100 090

expenditure figure - maintenance elPraumlsKon 103 111 100 111 100

eff operation time in daylighting zone (day) teffTagTL 683 h 937 h 608 h 937 h 856 h

eff operation time (night) teffNacht 1 h 2 h 1 h 2 h 2 h

eff operation time in el lighting zone (day) teffKTL 1019 h 1223 h 959 h 1223 h 1101 h

final energy use of building zone Qlbj 526 kWha 162 kWha 364 kWha 267 kWha 258 kWha

specific final energy use per squaremeter Qlbn 147 kWhmsup2a 45 kWhmsup2a 102 kWhmsup2a 75 kWhmsup2a 72 kWhmsup2a

expenditure figure for lighting el - - 661 486 500

Classroom 14 Light for better learning

The calculation according to DIN V 18599-4

2011-12 includes no method for activating

light and for lighting on a vertical plane

7 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery Kassel

View from North West before renovation East faccedilade after renovation South faccedilade after renovation

Floor plan of exhibition level (Heinrich von Dehn-Rotfelser ca 1870 (Source Wikipedia)

1870 Design by Heinrich von Dehn-Rotfelser 1877 Opening 1943 Bomb damages 1962-1976 Reconstruction and

reopening 2007-2011 renovation designed by Staab-Architekten Berlin lighting consultant Licht Kunst Licht with Roman

Jakobiak daylightingde

8 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery hall with rooflight before refurbishment

9 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

New design 2007 - 2011 by Staab-Architekten (Source Staab-Architekten)

Original design 1871 -1877 by Heinrich von

Dehn-Rotfelser (Source Erbe 1923)

Prismatic glazing

Roller blinds

Electric lighting

Double glazing

Scattering plastic

10 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

Prismatic glazing

Scattering plastic

Double glazing

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 4: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

4 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

profile of usage classroom (schools) after renovation before Reference

total blackboard working plane working plane EnEV 2009

installed power density pj 99 Wmsup2 53 Wmsup2 47 Wmsup2 138 Wmsup2 92 Wmsup2

expenditure figure for electric lighting system elK - - 153 453 315

gross window area ARB 623 msup2 623 msup2 623 msup2 623 msup2 623 msup2

area of daylighting zone ATL 2987 msup2 2987 msup2 2987 msup2 2987 msup2 2987 msup2

area of electric lighting zone AKTL 251 msup2 251 msup2 251 msup2 251 msup2 251 msup2

daylight factor for structure DRb 34 34 34 34 34

classification of daylight level - poor poor poor poor poor

factor daylight contribution (without shading) CTLVersSNA 070 070 070 070 067

factor daylight contribution (with shading) CTLVersSA 015 015 015 015 015

factor daylight contribution over all CTLVers 059 059 059 059 056

factor of daylight responsive controls CTLKon 063 05 0781 05 05

reduction factor for daylighting FTL 063 071 054 071 072

expenditure figure daylight elTLKon - - 126 159 154

factor of occupancy responsive controls CpraumlKon 071 050 095 050 050

reduction factor for occupancy FPrauml 082 088 076 088 088

expenditure figure - occupancy elPraumlsKon 110 117 102 117 117

reduction factor for maintenance FKL 095 100 090 100 090

expenditure figure - maintenance elPraumlsKon 106 111 100 111 100

eff operation time in daylighting zone (day) teffTagTL 701 h 863 h 518 h 863 h 790 h

eff operation time (night) teffNacht 2 h 2 h 1 h 2 h 2 h

eff operation time in el lighting zone (day) teffKTL 1099 h 1223 h 959 h 1223 h 1101 h

final energy use of building zone Qlbj 235 kWha 152 kWha 84 kWha 400 kWha 243 kWha

specific final energy use per squaremeter Qlbn 65 kWhmsup2a 42 kWhmsup2a 23 kWhmsup2a 111 kWhmsup2a 68 kWhmsup2a

expenditure figure for lighting el - - 196 934 566

Classroom 120 Energy efficient lighting

The calculation according to DIN V

18599-4 2011-12 includes no method

for lighting on a vertical plane

5 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom 14 Light for better learning

Classroom 14 before renovation Classroom 14 after renovation

6 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

profile of usage classroom (schools) after renovation before Reference

total blackboard working plane working plane EnEV 2009

installed power density pj 232 Wmsup2 53 Wmsup2 180 Wmsup2 87 Wmsup2 92 Wmsup2

expenditure figure for electric lighting system elK - - 554 268 315

gross window area ARB 595 msup2 595 msup2 595 msup2 595 msup2 595 msup2

area of daylighting zone ATL 3044 msup2 3044 msup2 3044 msup2 3044 msup2 3044 msup2

area of electric lighting zone AKTL 177 msup2 177 msup2 177 msup2 177 msup2 177 msup2

daylight factor for structure DRb 24 24 24 24 24

classification of daylight level - poor poor poor poor poor

factor daylight contribution (without shading) CTLVersSNA 055 055 055 055 052

factor daylight contribution (with shading) CTLVersSA 015 015 015 015 015

factor daylight contribution over all CTLVers 047 047 047 047 044

factor of daylight responsive controls CTLKon 072 05 078 05 05

reduction factor for daylighting FTL 066 077 063 077 078

expenditure figure daylight elTLKon - - 117 140 136

factor of occupancy responsive controls CpraumlKon 085 050 095 050 050

reduction factor for occupancy FPrauml 079 088 076 088 088

expenditure figure - occupancy elPraumlsKon 105 117 102 117 117

reduction factor for maintenance FKL 092 100 090 100 090

expenditure figure - maintenance elPraumlsKon 103 111 100 111 100

eff operation time in daylighting zone (day) teffTagTL 683 h 937 h 608 h 937 h 856 h

eff operation time (night) teffNacht 1 h 2 h 1 h 2 h 2 h

eff operation time in el lighting zone (day) teffKTL 1019 h 1223 h 959 h 1223 h 1101 h

final energy use of building zone Qlbj 526 kWha 162 kWha 364 kWha 267 kWha 258 kWha

specific final energy use per squaremeter Qlbn 147 kWhmsup2a 45 kWhmsup2a 102 kWhmsup2a 75 kWhmsup2a 72 kWhmsup2a

expenditure figure for lighting el - - 661 486 500

Classroom 14 Light for better learning

The calculation according to DIN V 18599-4

2011-12 includes no method for activating

light and for lighting on a vertical plane

7 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery Kassel

View from North West before renovation East faccedilade after renovation South faccedilade after renovation

Floor plan of exhibition level (Heinrich von Dehn-Rotfelser ca 1870 (Source Wikipedia)

1870 Design by Heinrich von Dehn-Rotfelser 1877 Opening 1943 Bomb damages 1962-1976 Reconstruction and

reopening 2007-2011 renovation designed by Staab-Architekten Berlin lighting consultant Licht Kunst Licht with Roman

Jakobiak daylightingde

8 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery hall with rooflight before refurbishment

9 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

New design 2007 - 2011 by Staab-Architekten (Source Staab-Architekten)

Original design 1871 -1877 by Heinrich von

Dehn-Rotfelser (Source Erbe 1923)

Prismatic glazing

Roller blinds

Electric lighting

Double glazing

Scattering plastic

10 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

Prismatic glazing

Scattering plastic

Double glazing

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 5: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

5 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom 14 Light for better learning

Classroom 14 before renovation Classroom 14 after renovation

6 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

profile of usage classroom (schools) after renovation before Reference

total blackboard working plane working plane EnEV 2009

installed power density pj 232 Wmsup2 53 Wmsup2 180 Wmsup2 87 Wmsup2 92 Wmsup2

expenditure figure for electric lighting system elK - - 554 268 315

gross window area ARB 595 msup2 595 msup2 595 msup2 595 msup2 595 msup2

area of daylighting zone ATL 3044 msup2 3044 msup2 3044 msup2 3044 msup2 3044 msup2

area of electric lighting zone AKTL 177 msup2 177 msup2 177 msup2 177 msup2 177 msup2

daylight factor for structure DRb 24 24 24 24 24

classification of daylight level - poor poor poor poor poor

factor daylight contribution (without shading) CTLVersSNA 055 055 055 055 052

factor daylight contribution (with shading) CTLVersSA 015 015 015 015 015

factor daylight contribution over all CTLVers 047 047 047 047 044

factor of daylight responsive controls CTLKon 072 05 078 05 05

reduction factor for daylighting FTL 066 077 063 077 078

expenditure figure daylight elTLKon - - 117 140 136

factor of occupancy responsive controls CpraumlKon 085 050 095 050 050

reduction factor for occupancy FPrauml 079 088 076 088 088

expenditure figure - occupancy elPraumlsKon 105 117 102 117 117

reduction factor for maintenance FKL 092 100 090 100 090

expenditure figure - maintenance elPraumlsKon 103 111 100 111 100

eff operation time in daylighting zone (day) teffTagTL 683 h 937 h 608 h 937 h 856 h

eff operation time (night) teffNacht 1 h 2 h 1 h 2 h 2 h

eff operation time in el lighting zone (day) teffKTL 1019 h 1223 h 959 h 1223 h 1101 h

final energy use of building zone Qlbj 526 kWha 162 kWha 364 kWha 267 kWha 258 kWha

specific final energy use per squaremeter Qlbn 147 kWhmsup2a 45 kWhmsup2a 102 kWhmsup2a 75 kWhmsup2a 72 kWhmsup2a

expenditure figure for lighting el - - 661 486 500

Classroom 14 Light for better learning

The calculation according to DIN V 18599-4

2011-12 includes no method for activating

light and for lighting on a vertical plane

7 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery Kassel

View from North West before renovation East faccedilade after renovation South faccedilade after renovation

Floor plan of exhibition level (Heinrich von Dehn-Rotfelser ca 1870 (Source Wikipedia)

1870 Design by Heinrich von Dehn-Rotfelser 1877 Opening 1943 Bomb damages 1962-1976 Reconstruction and

reopening 2007-2011 renovation designed by Staab-Architekten Berlin lighting consultant Licht Kunst Licht with Roman

Jakobiak daylightingde

8 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery hall with rooflight before refurbishment

9 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

New design 2007 - 2011 by Staab-Architekten (Source Staab-Architekten)

Original design 1871 -1877 by Heinrich von

Dehn-Rotfelser (Source Erbe 1923)

Prismatic glazing

Roller blinds

Electric lighting

Double glazing

Scattering plastic

10 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

Prismatic glazing

Scattering plastic

Double glazing

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 6: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

6 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

profile of usage classroom (schools) after renovation before Reference

total blackboard working plane working plane EnEV 2009

installed power density pj 232 Wmsup2 53 Wmsup2 180 Wmsup2 87 Wmsup2 92 Wmsup2

expenditure figure for electric lighting system elK - - 554 268 315

gross window area ARB 595 msup2 595 msup2 595 msup2 595 msup2 595 msup2

area of daylighting zone ATL 3044 msup2 3044 msup2 3044 msup2 3044 msup2 3044 msup2

area of electric lighting zone AKTL 177 msup2 177 msup2 177 msup2 177 msup2 177 msup2

daylight factor for structure DRb 24 24 24 24 24

classification of daylight level - poor poor poor poor poor

factor daylight contribution (without shading) CTLVersSNA 055 055 055 055 052

factor daylight contribution (with shading) CTLVersSA 015 015 015 015 015

factor daylight contribution over all CTLVers 047 047 047 047 044

factor of daylight responsive controls CTLKon 072 05 078 05 05

reduction factor for daylighting FTL 066 077 063 077 078

expenditure figure daylight elTLKon - - 117 140 136

factor of occupancy responsive controls CpraumlKon 085 050 095 050 050

reduction factor for occupancy FPrauml 079 088 076 088 088

expenditure figure - occupancy elPraumlsKon 105 117 102 117 117

reduction factor for maintenance FKL 092 100 090 100 090

expenditure figure - maintenance elPraumlsKon 103 111 100 111 100

eff operation time in daylighting zone (day) teffTagTL 683 h 937 h 608 h 937 h 856 h

eff operation time (night) teffNacht 1 h 2 h 1 h 2 h 2 h

eff operation time in el lighting zone (day) teffKTL 1019 h 1223 h 959 h 1223 h 1101 h

final energy use of building zone Qlbj 526 kWha 162 kWha 364 kWha 267 kWha 258 kWha

specific final energy use per squaremeter Qlbn 147 kWhmsup2a 45 kWhmsup2a 102 kWhmsup2a 75 kWhmsup2a 72 kWhmsup2a

expenditure figure for lighting el - - 661 486 500

Classroom 14 Light for better learning

The calculation according to DIN V 18599-4

2011-12 includes no method for activating

light and for lighting on a vertical plane

7 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery Kassel

View from North West before renovation East faccedilade after renovation South faccedilade after renovation

Floor plan of exhibition level (Heinrich von Dehn-Rotfelser ca 1870 (Source Wikipedia)

1870 Design by Heinrich von Dehn-Rotfelser 1877 Opening 1943 Bomb damages 1962-1976 Reconstruction and

reopening 2007-2011 renovation designed by Staab-Architekten Berlin lighting consultant Licht Kunst Licht with Roman

Jakobiak daylightingde

8 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery hall with rooflight before refurbishment

9 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

New design 2007 - 2011 by Staab-Architekten (Source Staab-Architekten)

Original design 1871 -1877 by Heinrich von

Dehn-Rotfelser (Source Erbe 1923)

Prismatic glazing

Roller blinds

Electric lighting

Double glazing

Scattering plastic

10 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

Prismatic glazing

Scattering plastic

Double glazing

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 7: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

7 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery Kassel

View from North West before renovation East faccedilade after renovation South faccedilade after renovation

Floor plan of exhibition level (Heinrich von Dehn-Rotfelser ca 1870 (Source Wikipedia)

1870 Design by Heinrich von Dehn-Rotfelser 1877 Opening 1943 Bomb damages 1962-1976 Reconstruction and

reopening 2007-2011 renovation designed by Staab-Architekten Berlin lighting consultant Licht Kunst Licht with Roman

Jakobiak daylightingde

8 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery hall with rooflight before refurbishment

9 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

New design 2007 - 2011 by Staab-Architekten (Source Staab-Architekten)

Original design 1871 -1877 by Heinrich von

Dehn-Rotfelser (Source Erbe 1923)

Prismatic glazing

Roller blinds

Electric lighting

Double glazing

Scattering plastic

10 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

Prismatic glazing

Scattering plastic

Double glazing

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 8: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

8 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery hall with rooflight before refurbishment

9 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

New design 2007 - 2011 by Staab-Architekten (Source Staab-Architekten)

Original design 1871 -1877 by Heinrich von

Dehn-Rotfelser (Source Erbe 1923)

Prismatic glazing

Roller blinds

Electric lighting

Double glazing

Scattering plastic

10 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

Prismatic glazing

Scattering plastic

Double glazing

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 9: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

9 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

New design 2007 - 2011 by Staab-Architekten (Source Staab-Architekten)

Original design 1871 -1877 by Heinrich von

Dehn-Rotfelser (Source Erbe 1923)

Prismatic glazing

Roller blinds

Electric lighting

Double glazing

Scattering plastic

10 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

Prismatic glazing

Scattering plastic

Double glazing

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 10: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

10 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery planning refurbishment

Prismatic glazing

Scattering plastic

Double glazing

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 11: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

11 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery during construction

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 12: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

12 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

New Gallery after refurbishment

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 13: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

I E A - T a s k 4 7 W o r k s h o p S y d n e y A u s t r a l i a

R e n o v a t i o n o f t h e

Fr ied r i ch -F roumlb e l - Sc h oo l

i n O l b e r s d o r f

Involved Institutions

Client Landkreis Goumlrlitz

Leader of Research Project HS ZittauGoumlrlitz Fakultaumlt Bauwesen Lehrgebiet Bauklimatik Prof Dr Bolsius

Subcontractor for Lighting TU-Dresden Fakultaumlt Architektur Institut fuumlr Bauklimatik

Subcontractor of Subcontractor for Lighting Roman Jakobiak (Werkvertrag)

Projektbegleitung Projekttraumlger Juumllich

Architect AIZ - Architektur- und Ingenieurbuumlro fuumlr Hoch- und Tiefbau Zittau GmbH

Electrical enginieering ILM - Ickrath Land Messner Ingenieurbuumlro fuumlr Elektroenergieanlagen

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 14: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

14 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Location of Olbersdorf

Federal Republic

of Germany

Saxony

County of Goumlrlitz

Olbersdorf

1927 Architectural competition

Winner Prof Jost Dresden

Start of construction

1929 Inauguration as primary school

1941 Camp for repatriates

1943 Military hospital

1945 Barracks of soviet army

1945 Reuptake of education

1958 Extension polytechnic centre

1968 Extension Kindergarten

1990 Conversion to middle school

2006 Closure of School

2007 Decision to renovate and to

reopen as special school

2011 Reopening as special school

Timeline of school

Source of map Wikipedia

specific annual delivered heating energy use

before renovation calculated 212 kWh(msup2a)

after renovation targeted 35 kWh(msup2a)

measured 32 kWh(msup2a)

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 15: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

15 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

2nd floor plan and cross section S

ou

rce

A

IZ

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 16: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

16 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Daylight level before renovation

low daylight level (window to floor area ratio = 17 DF 13)

adequate daylight level (window to floor area ratio = 32 DF 24)

So

urc

e A

IZ

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 17: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

17 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Glazing of double windows

Interior double low-E exterior Electrochromic glazing

windows already had been changed before renovation (double low-E)

Interior double low-E exterior single white glass

So

urc

e A

IZ

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 18: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

18 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old mock-up and new

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 19: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

19 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Window old and new

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 20: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

21 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

mock up with different glazing and daylighting systems

exterior upper window daylight

redirecting glass ldquoOkasolar Wrdquo

exterior lower window electrochromic

glazing interior window double low-E

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius E 50 (white)

exterior and interior glazing

double low-E

shading system Blinds Warema

Genius CE 50 (mirrored aluminum)

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 21: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

22 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash

metrics on window system

before renovation after renovation

area of classroom 5076 msup2 5076 msup2

opening area (gross) 870 msup2 870 msup2

opening to floor area ratio 17 17

reduction factor of frame 060 055

glazing area 524 msup2 479 msup2

glazed to floor area ratio 10 9

visible transmission of glazing 084 076

before renovation after renovation

Center 13 14

Reference point left side (half depth 1 m from left

sidewall)

11 09

Reference point right side (half depth 1 m from

right sidewall)

09 08

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

-10

-9

Southeast orientation

glazing

interior double low-E

exterior single white

shading blinds in double-

window

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 22: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

23 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Screen dump of monitoring system on 15th of March 2013 1058

monitoring of 549 data points in the lighting scan

Weather data

global solar radiation

direct solar radiation

Illuminance

wind speed

wind direction

relative humidity

external air temperature

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 23: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

24 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash interior view

window

(point 2)

middle

(point 3)

corridor

(point 4)

relative usable lighting contribution

(spring fall 9 am ndash 2 pm base 300 lx) 995 924 852

relative period of use

(spring fall 9 am ndash 2 pm base 300 lx) 964 717 627

cylindric horizontal

illuminance 662 875 1009

) monitoring was performed from 20102011 until 25102011

and from 11022012 until 16022012

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 24: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

25 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

standard classroom ndash control system

Control panel for teacher

location next to blackboard

secured by keyswitch

light switch

location next to entrance

Activation of room-lighting

daylighting systems and electric

lighting systems are adjusted in

order to safeguard the set-point-

illuminance

In case of direct sunlight

automated louver-blinds prevent

from glare

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 25: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

26 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

27 kWh(msup2a)

specific final annual energy lighting

energy use calculated with adjusted

profile of usage according to DIN V

18599-4

after renovation 273 kWh(msup2a)

before renovation 1095 kWh(msup2a)

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 26: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

27 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 27: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

28 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems ndash Blinds (Southeast-facing)

monthly relative period of relative extension of blinds

(lt8 recessed gt90 blinds completely cover the window)

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 28: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

29 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

floor plan of classroom with three facades

South and West

glazing

interior double low-E

exterior electrochromic

shading blinds in double-

window

North

glazing

interior double low-E

exterior single white

shading none

So

urc

e A

IZ

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 29: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

30 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Electrochromic glass

total energy transmittance

visible transmission D65

clear 36 50

tinted 12 15

Distortion of view at the edge of

electrochromic glazing

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 30: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

31 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom with three facades

summer spring fall winter

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx) 99 93 82

relative period of use

(9 am ndash 2 pm base 300 lx) 93 74 61

cylindric horizontal

illuminance 100 98 106

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 31: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

32 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific

lighting consumption

285 kWh(msup2a)

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 32: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

33 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 33: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

34 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash South facing

(automated + manual override)

EC-Glass ndash West facing

(automated + manual override)

Blinds ndash South facing

(operated manually) Blinds ndash West facing

(operated manually)

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 34: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

35 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Floor plan of the attic S

ou

rce

A

IZ

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 35: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

36 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

new rooflight

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 36: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

37 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in the attic

before renovation after renovation

area of classroom 75 msup2 75 msup2

opening area (gross) 803 msup2 1732 msup2

opening to floor area ratio 11 23

glazing area 508 msup2 1109 msup2

glazed to floor area ratio 7 15

before renovation after renovation

middle axis distance from window 226 m 25 12

center of room 13 11

middle axis distance from window 677 m 06 17

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 37: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

38 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Classroom in upper storey

EC-glass

Snow on rooflights

corridor

(point 4)

middle

(point 2)

window

(point 1)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

92

94

40

80

91

33

79

88

37

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

74

86

8

53

78

8

50

73

10

cylindric horizontal

illuminance

summer

spring

winter

34

39

48

66

59

75

65

78

75

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 38: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

39 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

occupancy amp operating hours of electric lighting

annual specific lighting

consumption

169 kWh(msup2a) in room 407

243 kWh(msup2a) in room 405

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 39: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

40 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

daylight amp operating hours of electric lighting

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 40: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

41 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Shading systems

EC-Glass ndash Southeast facing

(automated + manual override)

Blinds ndash Southeast facing

(operated manually)

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 41: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

42 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Olbersdorf special school

sports hall before refurbishment

Glazing area

after

renovation

039 msup2

glazing area

before

renovation

057 msup2

The new gallery windows have

68 of the glass area of the old

windows

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 42: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

43 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall ndash construction of new rooflight

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 43: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

44 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall

before renovation after renovation

floor area 350 msup2 350 msup2

opening area (gross) 393 msup3 802 msup2

opening to floor area ratio 11 23

glazing area 2117 msup2 5802 msup2

glazed to floor area ratio 6 17

before renovation after renovation

middle axis window area 10 27

center of room 07 31

middle axis rear side 03 20

Metrics on Window-System before and after renovation

Daylight factor before and after renovation

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 44: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

45 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

Sports hall with new rooflight

window

(point 1)

middle

(point 2)

next to

gallery

(point 3)

relative usable lighting contribution

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

100

96

55

100

97

60

99

91

42

relative period of use

(9 am ndash 2 pm base 300 lx)

summer

spring

winter

98

79

12

98

85

18

97

68

3

cylindric horizontal

illuminance

summer

spring

winter

42

48

40

42

47

40

49

51

46

Snow on rooflight

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 45: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

46 IEA-SHC-Task 47 Workshop Sydney 050413 Lighting standards in renovated buildings Roman Alexander Jakobiak

classrooms lighting energy consumption

lighting energy consumption in classrooms in

the first year of operation [kWh]

Specific lighting energy consumption in

classrooms in the first year of operation

[kWhmsup2]

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde

Page 46: IEA SHC || Task 47 || IEA SHC || Task 47 - Task 47 Workshop: …task47.iea-shc.org/.../6.Jakobiak-Lighting-Sydney.pdf · 2013-04-15 · 9 IEA-SHC-Task 47 Workshop, Sydney 05.04.13,

T h a n k Y o u

Task 47 Workshop Renovation of Non-

Residential Buildings towards Sustainable

Solutions Sydney 050413

Lighting standards in renovated

buildings

Roman Alexander Jakobiak

officedaylightingde