identifying energy saving potentials in buildings by ... identifying energy saving... ·...
TRANSCRIPT
![Page 1: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/1.jpg)
Identifying Energy Saving Potentials in Buildings
by Energy and System Monitoring Dr.-Ing. Benjamin Freiherr von Wolf-Zdekauer | CSCADE Study Visit, Mannheim
Bilfinger Bauperformance GmbH
September, 25th 2013
![Page 2: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/2.jpg)
Content
▪ Introduction
▪ Energy and System Monitoring
▪ Sample Projects
▪ Summary
Bilfinger Bauperformance GmbH
page 2
![Page 3: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/3.jpg)
0
500
1.000
1.500
2.000
2.500
3.000
3.500
4.000
4.500
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
Pri
mary
En
erg
y [
TW
h]
Trend of annual primary energy consumption in Germany
Consumption in total [Terra Wh/a]
Share of renewable energy sources [Terra Wh/a]
Introduction
Turnaround of Energy Policy
▪ Climate Protection Goals of EU till 2020
▪ 20-20-20:
20% Reduction of CO2-emission (adv. 2008)
20% Descent of energy consumption
20% Increase of renewable energy sources
▪ Measures
▪ EnEV 2014 and 2016 each with 12.5%
tightening compared to present EnEV
▪ Renewable Energies Act
▪ Renewable Thermal Energies Act
▪ Financial promotion programme …
Bilfinger Bauperformance GmbH
page 3
Turnaround of Energy Policy Change of Paradigm towards Energy of the Future
Source: AGEB BMWi 2012
![Page 4: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/4.jpg)
▪ Economic inefficiency of measures
▪ Existing systems „are still working“
▪ Different scopes of interest of owner and tenant
▪ Effect of utilisation / interruption of business
▪ Confusing variability and complexity of system variants
and legal requirements
▪ Uncertainty referring to financial support, tax
depreciation and feed-in tariffs (e.g. photovoltaic)
▪ 40 million housing units, thereof 75% erected before
1979
▪ Buildings of the 50ies to 70ies (approx. 35% of
building stock) pass through their first renovation
cycle in the next 10 years
▪ About 1/3 of all boilers in Germany are older than 20
years
▪ More than 80% of all heating systems in Germany are
oversized and / or are not correctly adjusted
▪ Energetic inspections are insufficiently carried out
Introduction
Situation Existing Buildings Bilfinger Bauperformance GmbH
page 4
Problem : Renovation rate only 1% p. a.
Solution : Awakening willingness to invest instead of pressure towards renovation!
POTENTIALS OBSTACLES
![Page 5: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/5.jpg)
0
50
100
150
200
250
300
1975 1980 1985 1990 1995 2000 2005 2010 2015
En
erg
y In
dex [
kW
h/(
m²*
a)]
Year
Level of Energy Performance ref. to WSVO/EnEV
Demand
Consumption
▪ From low-energy house standard to net plus energy
house
▪ Extensive energy design and simulation during
planning phase
▪ Complex energy supply systems with high percentage
of renewable energy sources
▪ Smart grid and networked building automation for
metering, control and switching
▪ Demands change due to variable business and
operation processes
Introduction
Situation New Buildings Bilfinger Bauperformance GmbH
page 5
Source: EnEV / WSVO / IGS TU-Braunschweig, 2011
WSVO 77
WSVO 84
WSVO 95
EnEV 2002
Problem : Design requirements are not realised, nonconformance of buildings
Solution : Energetical optimisation by precise adjusting of system parameter settings!
Correct Function?
Commissioning?
Start-up adjustment?
Hydraulic Balance?
User briefing?
CLAIM REALITY
EnEV 2009
![Page 6: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/6.jpg)
Content
▪ Introduction
▪ Energy and System Monitoring
▪ Sample Projects
▪ Summary
Bilfinger Bauperformance GmbH
page 6
![Page 7: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/7.jpg)
Energy and System Monitoring
Usual Steps for Energetical Retrofit of Existing Buildings Bilfinger Bauperformance GmbH
page 7
ACTUAL
100%
GOAL
up to
-50%
Insulation Building Envelope (Demand Reduction)
Modernisation Systems (Increase Energy Performance)
Exchange Control (Adequate Supply)
Payback Period
Savin
g E
ffect a
s to A
ctu
al C
onsum
ption
€€€
€€
€
Costs
Today Future
![Page 8: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/8.jpg)
For determination of „appropriate“ strategy of retrofit
Energy and System Monitoring
Our Approach: Generation of Quick Wins in Existing Buildings Bilfinger Bauperformance GmbH
page 8
ACTUAL
100% For Identification and Realisation of
immediate measures („Quick Wins“) by adaption of parameter settings
of systems
Short Payback Period
GOAL
up to
-15%
Savin
g E
ffect a
s to A
ctu
al C
onsum
ption
![Page 9: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/9.jpg)
Energy and System Monitoring
Own Innovation and Development Bilfinger Bauperformance GmbH
page 9
Competence of Data Collection
Logging of Measured Data Evaluation of Measured Data Client Report with
Recommendations for Optimisation
Competence of Analysation
Product Engineering Service Benefit of Client
Competence of reliable Consulting
for efficiency increase
+ =
![Page 10: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/10.jpg)
Energy and System Monitoring
Procedure and Analysis Process Bilfinger Bauperformance GmbH
page 10
▪ Data Acquisition
▪ Metering instruments with cable and radio based
sensors
▪ Logging of operation mode and system behavior
during a period of 1-3 weeks by „monitoring suitcase“
on site
▪ Daily transfer of data for verification by remote access
▪ Analysis
▪ Evaluation of collected data for identification of
effective savings and improvement potentials
▪ Transparency of daily profiles and percentages of
specific energy consumer
▪ Results
▪ Client report with presentation of saving strategy
▪ Realisation and result checking of measures
Supervision, verification
and analysis of daily
recorded monitoring data
Clarification
scopes and tasks
with customer
Temporary
measurement at
systems during
operation
Instruments in a
suitcase
Building
performance
Realisation of recommended measures,
and revision of savings
Evaluation of measured data of system
operation within transparent customer
reports
![Page 11: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/11.jpg)
▪ Situation:
Old "analog controller" provide
no data basis for optimisation
▪ Our metering and analysis
make energy flows visible
Only measured data is subject of
directed optimisation
Energy and System Monitoring
Application: Existing Buildings Bilfinger Bauperformance GmbH
page 11
![Page 12: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/12.jpg)
▪ Situation:
Complex system composition
with parameter settings only
according to design
specifications
▪ Our metering and analysis
check and optimise existing
system parameters
Energy and System Monitoring
Application: New Buildings Bilfinger Bauperformance GmbH
page 12
▪ Example:
Heating system with multiple heat generators in combination
Exclusively, the understanding of
system operation enables to
optimise it!
![Page 13: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/13.jpg)
Energy and System Monitoring
Real Estate “Health-Check“ Bilfinger Bauperformance GmbH
page 13
HUMAN
Examination
before Healing
REAL ESTATES
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
08.1
2.2
011
09.1
2.2
011
10.1
2.2
011
11.1
2.2
011
12.1
2.2
011
13.1
2.2
011
14.1
2.2
011
15.1
2.2
011
16.1
2.2
011
17.1
2.2
011
18.1
2.2
011
19.1
2.2
011
20.1
2.2
011
3-W
eg
e-M
isch
ers
tell
un
g [%
]
Tem
pera
ture
n [
C]
Temperaturverlauf Heizregister
VL Heizregister RLT400
RL Heizregister RLT400
VL Heizung
AUL Temp.
Mischer Heizregister
Measurement
before Saving
![Page 14: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/14.jpg)
Content
▪ Introduction
▪ Energy and System Monitoring
▪ Sample Projects
▪ Summary
Bilfinger Bauperformance GmbH
page 14
![Page 15: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/15.jpg)
Sample Projects
Generally: Decisions and Savings by Temporary Monitoring Bilfinger Bauperformance GmbH
page 15
Sustain
Exchange Adjustment
Retrofit
![Page 16: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/16.jpg)
Sample Projects
1. Temporary Monitoring Kindergarden Neckar Promenade (1) Bilfinger Bauperformance GmbH
page 16
▪ Pro-active replacement of circulation
pumps by high-efficiency pumps
▪ Nonreturn valve in piping for hot water
system due to fail-circulation
▪ Adoption of heating control function
(safety temperature limit – kids protection)
▪ Check of further reduction of connected
load of district heat
▪ Savings. approx. 13%
![Page 17: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/17.jpg)
Sample Projects
1. Temporary Monitoring Kindergarden Neckar Promenade (2) Bilfinger Bauperformance GmbH
page 17
![Page 18: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/18.jpg)
Sample Projects
2. Temporary Monitoring Kindergarden August-Kuhn Street (1) Bilfinger Bauperformance GmbH
page 18
▪ Confirmation of EnEV -30% level
▪ Commissioning Check
▪ Parametric adjustment of control
(pre-defined operation modes for
hot water storage and circulation)
▪ Demand oriented set-values and time
profiles of room temperatures
(system specific due to floor heating)
![Page 19: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/19.jpg)
Sample Projects
2. Temporary Monitoring Kindergarden August-Kuhn Street (2) Bilfinger Bauperformance GmbH
page 19
▪ Metering points
5
MP16 (TFA1)
MP17 (TFA2)
MP18 – MP21 Räume
6
1
7 8
11 12
9 10
13
14 15
4 2
3
![Page 20: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/20.jpg)
Sample Projects
2. Temporary Monitoring Kindergarden August-Kuhn Street (3) Bilfinger Bauperformance GmbH
page 20
▪ Statistic classification of
occurrence of system supply
temperatures
![Page 21: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/21.jpg)
Sample Projects
3. Measurement wattage and electric load profiles Arsenal of REM Bilfinger Bauperformance GmbH
page 21
▪ Plausibility of electric power demand and annual consumption
![Page 22: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/22.jpg)
Sample Projects
4. Start-up Monitoring Indoor Swimming Pool Neckarau Bilfinger Bauperformance GmbH
page 22
▪ Monitoring of district heat transfer station
▪ Analysis of Building Automation Trend logs:
▪ Control of heating circuits, hot water generation and pool heating
▪ Control of supply air temperatures of ventilation systems
![Page 23: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/23.jpg)
Sample Projects
5. Monitoring Ice Rink Herzogenried Bilfinger Bauperformance GmbH
page 23
▪ Monitoring icing phase
▪ Optimisation of waste-heat recovery and use
▪ Analysis summer case:
maximum cooling, minimum heating
▪ Analysis winter case:
maximum heating, minimum cooling
Operation transfer pump of desuperheater for
extracting heat from cooling system
Operation ground heating antifreeze protection
![Page 24: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/24.jpg)
Sample Projects
Room Measurements: Thermal Comfort, Humidity, ppm CO2, Lux Bilfinger Bauperformance GmbH
page 24
17
18
19
20
21
22
23
24
25
26
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36
Raum-AUL-Temperaturkorrelation
▪ Measurement of
▪ room temperature
▪ humidity
▪ supply temperatures
▪ precision adjustment of
room control loop
▪ increase of comfort
for user detailed analysis
air conditioning
Room temperature and Temperatures of Terminal
Unit
Correlation of internal and external temperatures
![Page 25: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/25.jpg)
Content
▪ Introduction
▪ Energy and System Monitoring
▪ Sample Projects
▪ Summary
Bilfinger Bauperformance GmbH
page 25
![Page 26: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/26.jpg)
Summary
Building Quality made by Bilfinger Bauperformance Bilfinger Bauperformance GmbH
page 26
Thermography
Quality measurement
air handling systems,
thermal comfort and
Lighting
Ultra Sonic
Flow-Meter
Blower-Door-
Test
Energy Monitoring
Building Systems
Praxis Proven Methods for Measuring and Improvement
Functional and Energetic Performance of Real Estates
Sound Level
Metering
Spherical
Camera
![Page 27: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/27.jpg)
Summary
Surplus Factors
Energy savings and cost cutting measures within short payback period
Security for clients in decisions about the adequate renovation strategy
Interruption of business and disturbance of systems for monitoring not required
Very flexible to use: …from residential buildings to laboratories,
…from simple heating systems to more complex HVAC-systems,
…for electric power, heating, chilling and water consumption
Increase of system reliability and energy efficiency by correction of inaccurate settings
Calculable period between monitoring and analysis results for client
Small measures with high outcome
Raise of attractiveness of real estates by reduction of running costs
Bilfinger Bauperformance GmbH
page 27
![Page 28: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/28.jpg)
Summary
Award as innovative Solution for Energy efficiency Bilfinger Bauperformance GmbH
page 28
![Page 29: Identifying Energy Saving Potentials in Buildings by ... Identifying Energy Saving... · Confirmation of EnEV -30% level Commissioning Check Parametric adjustment of control (pre-defined](https://reader033.vdocuments.us/reader033/viewer/2022043009/5f9d3dc30748604169723e82/html5/thumbnails/29.jpg)
Thank You for Your Kind Attention !
Dr.-Ing. Benjamin Freiherr von Wolf-Zdekauer