ico4s 2/2, 3/2 or 5/2 poppet valves electromagnetic ...cdn.norgren.com/pdf/en_5_7_550_ico4s.pdf ·...

12
ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled 12/15 en 5.7.550.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd. Medium: Hydraulic and pneumatic – customer to specify and confirm compatibility Operation: Direct solenoid operated poppet valves Mounting position: Solenoid vertical Flow: 0,8 Cv (11,5 Kv) ... 6,0 Cv (86,2 Kv) Port size: 1/4 NPT, 1/2 NPT, G1/4, G1/2 or manifold version Operating pressure: 0 ... 20 bar (0 ... 290 psi) 0 ... 50 bar (0 ... 725 psi) 0 ... 207 bar (0 ... 3002 psi) 0 ... 414 bar (0 ... 6004 psi) Temperature: Media: -20 ... +90°C (-4 ... +194°F) Options to -60°C (-76°F) available on request Ambient: See table on page 2 Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: high NBR Other seal materials available on request Technical features > Port size: 1/4” ... 3/4” (ISO G/NPT) or manifold version > Direct acting solenoid valve for the control of hydraulic or pneumatic equipment > High flow > Up to 414 bar inlet pressure > Reliable and long life, ideal for a one time installation > Certifications: ATEX, CSA, GOST K & R, IECEx, FM, CRN, CCOE IN-METRO > Environmental protection; NEMA 4X, IP66/X8

Upload: voxuyen

Post on 30-Aug-2018

268 views

Category:

Documents


0 download

TRANSCRIPT

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

12/15en 5.7.550.01

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

Medium:Hydraulic and pneumatic – customer to specify and confirm compatibilityOperation:Direct solenoid operated poppet valvesMounting position:Solenoid vertical

Flow:0,8 Cv (11,5 Kv) ... 6,0 Cv (86,2 Kv)Port size:1/4 NPT, 1/2 NPT, G1/4, G1/2 or manifold versionOperating pressure:0 ... 20 bar (0 ... 290 psi) 0 ... 50 bar (0 ... 725 psi) 0 ... 207 bar (0 ... 3002 psi) 0 ... 414 bar (0 ... 6004 psi)

Temperature:Media:-20 ... +90°C (-4 ... +194°F)Options to -60°C (-76°F) available on requestAmbient:See table on page 2Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

Materials:Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: high NBR Other seal materials available on request

Technical features

> Port size: 1/4” ... 3/4” (ISO G/NPT) or manifold version

> Direct acting solenoid valve for the control of hydraulic or pneumatic equipment

> High flow

> Up to 414 bar inlet pressure

> Reliable and long life, ideal for a one time installation

> Certifications: ATEX, CSA, GOST K & R, IECEx, FM, CRN, CCOE IN-METRO

> Environmental protection; NEMA 4X, IP66/X8

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.02

12/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

Technical data – standard models with conduit connection M20 x 1,5Symbol Port

sizeFunction Operating

pressure (bar)

Material Seat seal

Manual override/ reset

ATEXcertification

Power consumption 24 V d.c. (W)

Ambient temperature Weight

(kg)

Dimension

No.

Model

2

1

2

1

2

1

2

1

V-22C-E-F

V-22C-EH-F

V-22C-ER-F

1/4 NPT 2/2 NC 0 ... 20 NBR Without Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5 1 Y121AA1H1*S

G 1/4 2/2 NC 0 ... 20 NBR Without Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5 1 Y121AE1H1*S

1/2 NPT 2/2 NC 0 ... 50 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 2 Y131AA3H1*S

G 1/2 2/2 NC 0 ... 50 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 2 Y131AE3H1*S

1/2 NPT 2/2 NC 15 ... 414 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 3 Y191AA3J1*S

G 1/2 2/2 NC 15 ... 414 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 3 Y191AE3J1*S

3/4 NPT 2/2 NC 0-10 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 10 4 Y113AA5H1*S

G 3/4 2/2 NC 0-10 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 10 4 Y113AE5H1*S

21

Manifold 2/2 NC 0 ... 207 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 6 5 Y161AKFJ1*S

Manifold 2/2 NC 0 ... 414 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 6 5 Y191AKFJ1*S

2

1

1/4 NPT 2/2 NC 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 6 Y121PA1H1*S

G 1/4 2/2 NC 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 6 Y121PE1H1*S

1/2 NPT 2/2 NC 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 7 Y121PA3H1*S

G 1/2 2/2 NC 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 7 Y121PE3H1*S

3

2

1 3

2

1 3

2

1 3

V-32C-E-F

V-32C-EH-F

V-32C-ER-F

1/4 NPT 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 8 Y123AA1H1*S

G 1/4 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 8 Y123AE1H1*S

1/2 NPT 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 9 Y123AA3H1*S

G 1/2 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 9 Y123AE3H1*S

3/4 NPT 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 10 10 Y113AA5H1*S

G 3/4 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 10 10 Y113AE5H1*S

2

1 3

1/4 NPT 3/2 UNI 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 11 Y123PA1H1*S

G 1/4 3/2 UNI 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 11 Y123PE1H1*S

1/2 NPT 3/2 UNI 0 ... 20 NBR PBMR* Exd IIC T6 6,0 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 12 Y123PA3H1*S

G 1/2 3/2 UNI 0 ... 20 NBR PBMR* Exd IIC T6 6,0 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 12 Y123PE3H1*S

3

2

1 3

1/4 NPT 3/2 UNI 0 ... 20 NBR A-L-L* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 13 Y123BA1H1*S

G 1/4 3/2 UNI 0 ... 20 NBR A-L-L* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 13 Y123BE1H1*S

1/2 NPT 3/2 UNI 0 ... 20 NBR A-L-L* Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 14 Y123BA3H1*S

G 1/2 3/2 UNI 0 ... 20 NBR A-L-L* Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 14 Y123BE3H1*S

2

1 3

1/4 NPT 3/2 UNI 0 ... 20 NBR JSMO* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 15 Y123SA1H1*S

G 1/4 3/2 UNI 0 ... 20 NBR JSMO* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 15 Y123SE1H1*S

24

15 3

24

15 3

24

15 3

V-52-E-F

V-52-EH-F

V-52-EH-F

1/4 NPT 5/2 UNI 0 ... 12 NBR Without Exd IIC T6 4,7 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 16 Y115AA1H1*S

G 1/4 5/2 UNI 0 ... 12 NBR Without Exd IIC T6 4,7 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 16 Y115AE1H1*S

* Insert voltage code - shown in option selector on page 3 Other product and body material available for more information contact Maxseal technical service PBMR = Push button manual reset, A-L-L = Automatic latching lever, JSMO = Jack screw manual override

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.0312/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

Y1˙˙˙˙˙˙˙˙SOption selector

Operating pressure Substitute

0 ... 20 bar (0 ... 290 psi) 2

0 ... 50 bar (0 ... 725 psi) 3

0 ... 207 bar (0 ... 3002 psi) 6

0 ... 414 bar 9

Number of ports Substitute

2 /2 NC (standard) 1

2 /2 NO 2

3/2 NC (universal) 3

5/2 5

Operation Substitute

Automatic A

Automatic latching lever B

Push button manual override C

Push button manual reset P

Jack screw manual override S

Tamper proof manual reset T

Port size Substitute

1/4 NPT A1

G 1/4 E1

1/2 NPT A3

G 1/2 E3

3/4 NPT A5

G 3/4 E5

Manifold KF

Voltage Substitute

18 /33 V d.c. A

24 V d.c. B

48 /50 V d.c. (50 V) C

110 V d.c. D

125 V d.c. E

220 /240 V d.c. (240 V) F

24 V a.c. G

110 V a.c. J

12 V d.c. L

220 /240 V a.c. (240 V) M

Conduit connection Substitute

M20 x 1.5 mm 1

1/2 NPT 2

Seat /seal material Substitute

High Nitrile (standard) H

FKM V

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.04

12/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

Dimensions

1

2

57

30

21

38,5

36,5

180

21,5 32

,5

51 ø 56

55 22

20

58,5 ø 82

1

2

12

M8

View

A

A

104

30

21

38,5

36,5

227

58

60

70 ø 76

55 22

20

58,5 ø 82

1

2

2

1

M8

55 22

M8

View A

A

1 Conduit connection M20 x 1,5 or 1/2 NPT2 External earth

Dimensions in mm Projection/First angle

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.0512/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

3

4

30

21

38,5

36,5

303

ø 35 ø76

20

58,5 ø 82

68

1

2

1

2

127

85

62

55 22

M8

View A

A

105

30

21

38,5

36,5

26

235

39

1

3

2

20

58,5 ø 82

57

60

74

30,5

70

1

2

55 22

M8

View A

A

1 Conduit connection M20 x 1,5 or 1/2 NPT2 External earth

Dimensions in mm Projection/First angle

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.06

12/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

63

30

21

38,5

36,5

192

37

6,8

51

20

58,5 ø 82

17

51

38

1

2

55 22

M8

View A

A

1127

21

3

7730

21

38,5

36,5

200

1442 53

51

12

ø 57

20

58,5 ø 82

1

2

6

55 22M

8

View A

A

5

6

Dimensions in mm Projection/First angle

1 Conduit connection M20 x 1,5 or 1/2 NPT2 External earth3 ø 5 mm drilled ports supplied with O-rings6 Push button manual reset

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.0712/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

6830

21

38,5

36,5

190

21,5 32

,5 43,5

51

3

12

ø 56

20

58,5 ø 82

1

2

55 22

M8

View A

A

124,

530

21

38,5

36,5

247,

5

78,5 80

,570

1

2

ø 76

20

58,5 ø 82

14

1

2

6

55 22

M8

View A

A7

8

1 Conduit connection M20 x 1,5 or 1/2 NPT2 External earth6 Push button manual reset

Dimensions in mm Projection/First angle

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.08

12/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

120

30

21

38,5

36,5

243

58

80

70

1

3

2

ø 76

20

58,5 ø 82

36

1

2

55 22

M8

View A

A

105

30

21

38,5

36,5

235

57

85

74

1

3

2

70

20

58,5 ø 82

26

39 30

1

2

55 22M

8

View A

A

9

10

1 Conduit connection M20 x 1,5 or 1/2 NPT2 External earth

Dimensions in mm Projection/First angle

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.0912/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

8930

21

38,5

36,5

211

14

53 64,5

51

3

12

ø 57

20

58,5 ø 82

1

2

6

55 22

M8

View A

A

142

30

21

38,5

36,5

265

80

102

70

1

3

2

ø76

20

58,5 ø 82

1458

1

2

6

55 22

M8

View A

A

11

12

1 Conduit connection M20 x 1,5 or 1/2 NPT2 External earth6 Push button manual reset

Dimensions in mm Projection/First angle

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.10

12/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

6330

21

38,5

36,5

186

17

28

393

12

5651

20

58,5 ø 82

1

2

7

55 22

M8

View A

A

120

30

21

38,5

36,5

243

58

80

70

1

3

2

76

20

58,5 ø 82

36

1

2

7

55 22M

8

View A

A

13

14

1 Conduit connection M20 x 1,5 or 1/2 NPT2 External earth7 Automatic latching lever

Dimensions in mm Projection/First angle

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.1112/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

8930

21

38,5

36,5

211

42 53 64,5

51

3

12

ø 57

20

58,5 ø 82

1

2

5

55 22

M8

View A

A

??

30

21

38,5

36,5

264

48

44

1

4

2

3

5

28,5

20

58,5 ø 82

4817

48

41

63,5

1

2

55 22

M8

View A

A

15

16

1 Conduit connection M20 x 1,5 or 1/2 NPT2 External earth5 Jack screw manual override

Dimensions in mm Projection/First angle

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

en 5.7.550.12

12/15Our policy is one of continued research and development. We therefore reserve the right to amend, without

notice, the specifications given in this document. (2012 - 5198c) © IMI Precision Engineering, Thompson Valves Ltd.

WarningThese products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«.Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Thompson Valves Ltd.Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.

The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with these products. For further information please see Functional Safety Manual MI0560.