icc-es evaluation report esr-1647* - boral usa fills/e… · · 2014-05-02esr-1647 | most widely...
TRANSCRIPT
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2014 Page 1 of 10 1000
ICC-ES Evaluation Report ESR-1647* Issued July 2013 This report is subject to renewal August 1, 2015.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ®
DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION
Section: 07 32 16—Concrete Roof Tiles REPORT HOLDER:
BORAL ROOFING 7575 IRVINE CENTER DRIVE, SUITE 100 IRVINE, CALIFORNIA 92618 (949) 756-1605 www.boralna.com [email protected] EVALUTION SUBJECT: CONCRETE ROOF TILES: ATLANTIS, BARCELONA 900, BARCELONA-IMPACT, CAPRI, CEDARLITE / CEDARLITE 600, CLASSIC 100, ESPANA / BARCELONA, ESPANA 600, HOMESTEAD SHAKE, HOMESTEAD – SLATE, MADERA, MADERA 700, MISSION S / BARCELONA, ROMA, SAXONY, SAXONY 600, SAXONY 700, SAXONY 900, SAXONY-SHAKE, SAXONY-SLATE, SAXONY-COUNTRY SLATE, SAXONY-SPLIT SHAKE, SAXONY SPLIT SLATE, SAXONY-IMPACT, SAXONY 900-IMPACT, SPANISH “S”, SPANISH “S” NUEVO, TEJAS ESPANA, VANGUARD ROLL, VILLA, VILLA 600, VILLA 900 AND VILLA 900-IMPACT 1.0 EVALUATION SCOPE
Compliance with the following codes: 2012 and 2009 International Building Code® (IBC) 2012 and 2009 International Residential Code® (IRC) Other Codes (See Section 8.0) Properties evaluated: Fire classification Weather resistance Wind-uplift resistance
2.0 USES The Boral Roofing concrete roof tiles installed over solid sheathing are used as Class A roof coverings in accordance with Section 1505.2 of the IBC and Section R902.1 of the IRC.
3.0 DESCRIPTION 3.1 Interlocking Concrete Roof Tiles: These roof tiles are extruded interlock concrete roof tiles that comply with ASTM C1492 and having interlocking ribs on the longitudinal edges of the tiles to restrict lateral
movement and provide a water stop. All roof tiles are designed with anchor lugs except for the Cedarlite and Madera profiles. Mineral coloring oxides are either applied to the exposed surface in a cementitious material or mixed integrally with the tile mix to produce a through-colored product.
All roof tiles are cured to reach required strength before shipment. Product designations, dimensions and installed dry weights are indicated in Table 1 of this report. Roof tile profiles are illustrated in Figure 1. 3.2 Concrete Roof Tiles: Spanish “S” roof tiles are extruded concrete roof tiles that comply with ASTM C1492. The roof tile is manufactured in the same manner as the roof tiles described in Section 3.1, except the tile is non-interlocking. The roof tile is designed without anchor lugs. The product designation, dimensions and installed dry weight are indicated in Table 1. See Figure 1 for an illustration of the tile.
4.0 INSTALLATION 4.1 General Installation of the Boral Roofing roof tiles must be in accordance with the Concrete and Clay Roof Tile Installation Manual for Moderate Climate Regions, dated March 2010, published by the Tile Roofing Institute and Western States Roofing Contractors Association (hereinafter referred to as the TRI/WSRCA installation manual), and recognized in ESR-2015P, except as otherwise noted in this report. In case of a conflict between the installation manual and this report, this report governs. This report and the TRI/WSRCA installation manual must be available at the jobsite at all times during installation. The roof tiles must be installed on a minimum roof slope of 21/2:12 (20.83%). Care must be taken during field installation to ensure that horizontal joints are kept parallel to the eave and vertical joints are at right angles to the eave in order to ensure uniform contact between the tiles and proper fit and appearance. All cracked and broken roof tiles must be replaced. 4.2 Adhesive Set Systems: The Boral Roofing roof tiles may be installed with roof tile adhesives that are recognized in a current ICC-ES evaluation report for use in concrete roofing tile applications. Installation of tiles using these adhesive set systems must be in accordance with the adhesive manufacturer’s ICC-ES evaluation report. 4.3 Mortar Set Systems: Except for the Villa 600, Barcelona 600, Saxony 600, Cedarlite/Cedarlite 600 and Madera tiles, the Boral Roofing
*Revised April 2014
ESR-1647 | Most Widely Accepted and Trusted Page 2 of 10
roof tiles may be installed with mortars that are recognized in a current ICC-ES evaluation report for use in concrete roofing tile applications. Installation of tiles using these mortar set systems must be in accordance with the mortar manufacturer’s ICC-ES evaluation report. 4.4 Wind Resistance: 4.4.1 Cedarlite / Cedarlite 600, Madera and Madera 700: 4.4.1.1 2012 IBC: Installation of these tiles is limited to the prescriptive parameters of Table 1507.3.7 for ultimate design wind speeds (Vult) of 130 mph (209 km/h) or less and mean roof heights of 60 feet (18.3 m) or less.
As an alternative, on minimum 7/16-inch-thick (11.1 mm) oriented strand board or minimum 15/32-inch-thick (11.9 mm) plywood, a single corrosion-resistant, buglehead wood screw, in the center fastener hole, may be used in lieu of the two nails required for roof slopes of 3:12 and over. The screw must be of sufficient length to penetrate through the deck a minimum of 3/4 inch (19.1 mm). The buglehead screw must have a shank diameter of 0.138 inch (3.5 mm) and a head diameter of 0.328 inch (8.3 mm).
The tile may be installed with battens. Battens installed must be nominally 1-inch-by-3-inch wood. Each tile must be fastened to the batten with a single corrosion-resistant, buglehead wood screw in the center fastener hole. The screw must penetrate the batten a minimum of 3/4 inch (19.1 mm) but must not penetrate the underlayment. The top edge of the tile is aligned with the top of the batten. 4.4.1.2 2012 IRC and 2009 IBC and IRC: Installation of these tiles is limited to the prescriptive parameters of Table 1507.3.7 of the IBC and Section R905.3.7 of the IRC, as applicable, for basic wind speeds (3-second gust) of 100 mph (161 km/h) or less and mean roof heights of 60 feet (18 288 mm) or less for the IBC and 40 feet (12 192 mm) or less for the IRC.
See Section 4.4.1.1 for fastening of sheathing with single screw in lieu of two nails for roof slopes of 3:12 and over.
Also, see Section 4.4.1.1 for tile installation on battens. 4.4.2 All Other Tiles Except Cedarlite / Cedarlite 600, Madera and Madera 700: 4.4.2.1 2012 IBC: For ultimate design wind speeds (Vult) of 130 mph (209 km/h) or less and mean roof heights of 60 feet (18.3 m) or less, tiles must be installed in accordance with the prescriptive parameters of Table 1507.3.7 of the IBC. For applications beyond these prescriptive parameters, the tiles and the fastening systems must be designed in accordance with Figure 1 of ESR-2015P, Design Considerations for High Wind Applications Under the 2012 IBC and IRC (ASCE 7-10). 4.4.2.2 2012 IRC: For basic wind speeds (3-second gust) of 100 mph (161 km/h) or less and mean roof heights of 40 feet (12 192 mm) or less, tiles must be installed in accordance with the prescriptive parameters of Section R905.3.7 of the IRC. For applications beyond these prescriptive parameters, the tiles and the fastening systems must be designed in accordance with Figure 1 of ESR-2015P, Design Considerations for High Wind Applications Under the 2012 IBC and IRC (ASCE 7-10). 4.4.2.3 2009 IBC and IRC: For basic wind speeds (3-second gust) of 100 mph (161 km/h) or less and mean roof heights of 60 feet (18 288 mm) or less for the IBC or 40 feet (12 192 mm) or less for the IRC, tiles must be installed in accordance with the prescriptive parameters of Table 1507.3.7 of the IBC or Section R905.3.7 of the IRC, as applicable. For applications beyond these prescriptive parameters, the tiles and the fastening systems must
be designed to withstand the aerodynamic wind uplift moment in accordance with the section on Design Considerations for High Wind Applications in Appendix B of the TRI/WSRCA installation manual. The generic required aerodynamic uplift moment, determined in accordance with Tables 5A through 6D of the TRI/WSRCA installation manual, must be multiplied by the tile factor ratio in Table 2 to obtain the required aerodynamic uplift moment for the specific roof tile being installed. The allowable aerodynamic uplift moment for the roof tile fastening system selected from Table 7A of the TRI/WSRCA installation manual, must be equal to or greater than the required aerodynamic uplift moment for the specific roof tile being installed. 4.5 Fire Classification: When installed in accordance with this report, the Boral Roofing concrete roof tiles are Class A roof coverings in accordance with IBC Section 1505.2 and IRC Section R902.1. When roof tiles are installed with a roof tile adhesive, installation must be in accordance with ESR-1709.
5.0 CONDITIONS OF USE The Boral Roofing extruded concrete roof tiles described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The roof tiles must be installed in accordance with this
report, the applicable code and the TRI/WSRCA installation manual. In case of a conflict between the installation manual and this report, this report must govern.
5.2 The roof decking and roof framing system must be designed for the appropriate loads determined in accordance with the applicable code.
5.3 The Boral Roofing concrete roof tiles are produced at the manufacturing facilities specified in Table 1 under a quality control program with inspections by ICC-ES.
6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Clay and Concrete Roof Tiles (AC180), dated February 2012.
7.0 IDENTIFICATION The underside of each field tile, except for Cedarlite / Cedarlite 600, Madera 700 and Madera tiles, is imprinted with the MonierLifetile or Boral Roofing logo (Figure 2) or the name MonierLifetile, Boral, Boral Lifetile or Vostile. Cedarlite / Cedarlite 600, Madera 700 and Madera tiles have an “M” imprinted on the top side of each tile. Each shipping pallet must have a label bearing the Boral Roofing name; the tile designation; manufacturing location and address; color; SAP number; quantity of tiles per pallet; production date; installed weight; and the evaluation report number (ESR-1647).
8.0 OTHER CODES In addition to the codes referenced in Section 1.0, the products in this report were evaluated for compliance with the requirements of the following codes: 2006 International Building Code® (IBC) 2006 International Residential Code® (IBC)
The Boral Roofing concrete roof tiles installed over solid or spaced sheathing are considered Class A in accordance with the exception to 2006 IBC Section 1505.2 and 2006 IRC Section R902.1. All other conditions of recognition are as described in Sections 2.0 through 7.0.
ESR-1647 | Most Widely Accepted and Trusted Page 3 of 10
TABLE 1—TILE DIMENSIONS, WEIGHTS AND MANUFACTURING FACILITIES
TILE DESIGNATION INSTALLED DRY WEIGHT1 (psf)
DIMENSIONS2 (in.) MANUFACTURING FACILITY
LENGTH WIDTH
Atlantis - Slate 10.4 161/8 101/8 Pompano
Atlantis - Textured 10.4 161/8 101/8 Pompano
Barcelona 900 9.5 17 13 Lake Wales
Barcelona 900 9.3 17 13 Lathrop
Barcelona - Impact 10.3 161/2 13 Katy
Capri 10.1 17 123/8 Lake Wales
Cedarlite / Cedarlite 600 5.9 131/2 13 Gilroy
Espana / Barcelona 9.0 17 123/8 Henderson
Espana / Barcelona 8.5 17 123/8 Lake Wales
Espana / Barcelona 9.0 17 123/8 Lathrop
Espana / Barcelona 9.0 17 123/8 Rialto
Espana 600 / Barcelona 600 5.9 17 123/8 Rialto
Saxony 900 - Hartford Slate 9.1 17 13 Stockton
Madera 9.5 131/2 13 Gilroy
Madera 700 7.2 131/2 13 Gilroy
Mission S / Barcelona 10.3 161/2 13 Phoenix
Saxony 900 - Split Old English Thatch 9.8 17 13 Stockton
Saxony - Country Shake 10.3 161/2 13 Katy
Saxony - Country Shake 10.3 17 123/8 Rialto
Saxony - Country Slate 10.3 161/2 13 Katy
Saxony - Country Slate 10.3 17 123/8 Rialto
Saxony - Country Split Shake 10.3 161/2 13 Katy
Saxony - English Thatch 10.3 161/2 13 Katy
Saxony - English Thatch 10.3 17 123/8 Rialto
Saxony - English Thatch 10.4 17 123/8 Lake Wales
Saxony - Shake 10.3 161/2 13 Katy
Saxony - Shake 9.5 161/2 13 Phoenix
Saxony - Shake 10.3 17 123/8 Rialto
Saxony - Shake 10.4 17 123/8 Lake Wales
Saxony - Shake 9.6 17 13 Denver
Saxony 900 - Shake 9.1 17 13 Lathrop
Saxony 900 - Shake 9.1 17 13 Stockton
Saxony - Slate 9.5 161/2 13 Phoenix
Saxony - Slate 10.3 161/2 13 Katy
Saxony - Slate 10.3 17 123/8 Rialto
Saxony - Slate 10.4 17 123/8 Lake Wales
Saxony 900 - Slate 9.1 17 13 Lathrop
Saxony 900 - Slate 9.1 17 13 Stockton
Saxony 900 - Country Slate 9.1 17 13 Stockton
Saxony - Slate 9.6 17 13 Denver
Saxony - Country Slate 9.6 17 13 Denver
Saxony - Split Old English Thatch 9.6 17 13 Denver
Saxony - Split Shake 10.3 17 123/8 Rialto
Saxony - Split Shake 10.4 17 123/8 Lake Wales
Saxony - Split Slate 10.3 17 123/8 Rialto
For SI: 1 inch = 25.4 mm, 1 psf = 4.88 kg/m2.
ESR-1647 | Most Widely Accepted and Trusted Page 4 of 10
TABLE 1—TILE DIMENSIONS, WEIGHTS AND MANUFACTURING FACILITIES (Continued)
TILE DESIGNATION INSTALLED DRY WEIGHT1 (psf)
DIMENSIONS2 (in.) MANUFACTURING FACILITY
LENGTH WIDTH
Saxony - Split Slate 10.4 17 123/8 Lake Wales
Saxony 600 - Shake 5.7 17 13 Stockton
Saxony 600 - Slate 5.7 17 13 Stockton
Saxony 600 - Split Shake 5.7 17 13 Stockton
Saxony 700 - Shake 7.2 17 13 Stockton
Saxony 700 - Slate 7.2 17 13 Stockton
Saxony 700 – Split Shake 7.2 17 13 Stockton
Saxony 700 - Shake 7.1 17 13 Rialto
Saxony 700 - Slate 7.1 17 13 Rialto
Saxony 700 – Split Shake 7.1 17 13 Rialto
Saxony 900 - Shake 9.1 17 13 Henderson
Saxony 900 - Slate 9.1 17 13 Henderson
Saxony 900 - Country Slate 9.1 17 13 Henderson
Saxony 900 - Shake 9.5 17 13 Lake Wales
Saxony 900 - Slate 9.5 17 13 Lake Wales
Saxony 900 – Split Shake 9.5 17 13 Lake Wales
Saxony 900 – Country Slate 9.5 17 13 Lake Wales
Spanish “S” 9.5 18 103/8 Pompano
Tejas Espana / Barcelona 9.0 161/2 13 Katy
Vanguard Roll 8.4 161/2 13 Pompano
Villa 9.6 161/2 13 Phoenix
Villa 900 9.0 17 13 Rialto
Villa 900 9.0 17 13 Denver
Villa 600 5.8 17 13 Rialto
Villa 600 6.0 17 13 Stockton
Villa 900 9.3 17 13 Stockton
Villa 9.0 161/2 13 Katy
Villa 900 9.2 17 13 Lake Wales
Spanish “S” Nuevo 9.9 17 93/4 Lake Wales
Saxony 600 5.9 17 13 Rialto
Saxony 900 9.3 17 13 Rialto
Saxony – Impact 10.5 16½ 13 Katy
Saxony – Impact 10.5 17 13 Denver
Saxony 900 – Impact 10.4 17 13 Stockton
Villa 900 – Impact 10.1 17 13 Denver
Classic 100 9.5 16½ 13 Tacoma
Homestead – Shake 9.8 16½ 13 Tacoma
Homestead – Slate 9.8 16½ 13 Tacoma
Roma 9.3 16½ 13 Tacoma
Saxony – Shake 10.5 16½ 13 Tacoma
Saxony – Slate 10.5 16½ 13 Tacoma
Saxony – Country Slate 10.5 16½ 13 Tacoma
Saxony – Split Shake 10.5 16½ 13 Tacoma
Saxony – Split Slate 10.5 16½ 13 Tacoma
Villa 9.0 16½ 13 Tacoma
For SI: 1 inch = 25.4 mm, 1 psf = 4.88 kg/m2. 1Installed dry weight is based on a 3-inch headlap. 2All dimensions are nominal.
ESR-1647 | Most Widely Accepted and Trusted Page 5 of 10
TABLE 2—TILE FACTORS AND TILE FACTOR RATIOS
TILE DESIGNATION TILE FACTOR (ft3) TILE FACTOR RATIO1
Capri
1.407 (Base Tile Factor) 1.000
Mission S / Barcelona
Saxony2
Split Old English Thatch
Tejas Espana
Vanguard Roll
Villa
Classic 100
Homestead - Shake
Homestead - Slate
Roma
Saxony – Impact
Atlantis Slate / Atlantis Textured 1.013 0.720
Spanish “S” 1.265 0.899
Spanish “S” Nuevo 1.144 0.813
Espana / Barcelona
1.525 1.084
Espana 600 / Barcelona 600
Barcelona 900
Barcelona - Impact
Saxony 600
Saxony 700
Saxony 900
Saxony 900 Hartford Slate
Saxony 900 Split Old English Thatch
Villa 600
Villa 900
Villa 900 – Impact
Saxony 900 – Impact 1Tile factor ratio = tile factor / Base tile factor of 1.407 ft3. See Section 4.4.2 of this report and Appendix B of the TRI/WSRCA installation manual for additional details. 2Saxony includes the following profiles: Saxony – Shake, Slate, Split Shake, Split Slate, Country Shake, Country Slate, Country Split Shake, English Thatch and Split Old English Thatch.
ESR-1647 | Most Widely Accepted and Trusted Page 6 of 10
FIGURE 1—TILE ILLUSTRATIONS
Atlantis—Textured Atlantis—Slate
Espana / Barcelona Barcelona 900
Espana 600 / Barcelona 600 Barcelona - Impact
ESR-1647 | Most Widely Accepted and Trusted Page 7 of 10
Saxony–Impact Saxony 900–Impact
FIGURE 1—TILE ILLUSTRATIONS (Continued)
Madera Madera 700
Cedarlite/Cedarlite 600
Saxony—Country Slate Saxony 900—Country Slate
ESR-1647 | Most Widely Accepted and Trusted Page 8 of 10
FIGURE 1—TILE ILLUSTRATIONS (Continued)
Saxony 900—Split Old English Thatch Saxony—Split Old English Thatch
Saxony—Split Shake
Saxony–Impact Saxony 900–Impact
ESR-1647 | Most Widely Accepted and Trusted Page 9 of 10
FIGURE 1—TILE ILLUSTRATIONS (Continued)
Spanish “S” Nuevo
Nail hole may be located on the pan depending on manufacturing location.
Villa Villa 600 Villa 900 Villa 900–Impact
ESR-1647 | Most Widely Accepted and Trusted Page 10 of 10
FIGURE 1—TILE ILLUSTRATIONS (Continued)
FIGURE 2—MONIERLIFETILE LOGO OR BORAL ROOFING LOGO
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2014 Page 1 of 1 1000
ICC-ES Evaluation Report ESR-1647 CBC and CRC Supplement* Reissued July 2013 This report is subject to renewal August 1, 2015.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ®
DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 32 16—Concrete Roof Tiles
REPORT HOLDER:
BORAL ROOFING 7575 IRVINE CENTER DRIVE, SUITE 100 IRVINE, CALIFORNIA 92618-2930 (949) 756-1605 www.boralna.com [email protected] EVALUATION SUBJECT:
CONCRETE ROOF TILES: ATLANTIS, BARCELONA 900, BARCELONA—IMPACT, CAPRI, CEDARLITE / CEDARLITE 600, CLASSIC 100, ESPANA / BARCELONA, ESPANA 600, HOMESTEAD SHAKE, HOMESTEAD—SLATE, MADERA, MADERA 700, MISSION S / BARCELONA, ROMA, SAXONY, SAXONY 600, SAXONY 700, SAXONY 900, SAXONY—SHAKE, SAXONY—SLATE, SAXONY—COUNTRY SLATE, SAXONY—SPLIT SHAKE, SAXONY—SPLIT SLATE, SAXONY—IMPACT, SAXONY 900—IMPACT, SPANISH “S” , SPANISH “S” NUEVO, TEJAS ESPANA, VANGUARD ROLL, VILLA, VILLA 600, VILLA 900 AND VILLA 900—IMPACT
1.0 EVALUATION SCOPE Compliance with the following codes: 2010 California Building Code 2010 California Residential Code Properties evaluated: Fire classification Weather resistance Wind-uplift resistance
2.0 California Building Code (CBC) The Boral Roofing concrete roof tiles described in the master report ESR-1647 may be used where a Class A roof covering complying with CBC Section 1505.1.1, a Class B roof covering complying with CBC Section 1505.1.2, or a Class C roof covering complying with CBC Section 1505.1.3 is required, provided installation is in accordance with the master report and the additional requirements of Sections 1507.3.10 and 1511 of the CBC.
The roof tiles may be used in the construction of new buildings located in a Fire Hazard Severity Zone within State Responsibility Areas or any Wildland–Urban Interface Fire Area, provided installation is also in accordance with the master report and the additional requirements of Sections 701A.3 and 705A of the CBC.
3.0 California Residential Code (CRC) The Boral Roofing concrete roof tiles described in the master report ESR-1647 may be used where a Class A roof covering complying with CRC Section R902.1.1, a Class B roof covering complying with CRC Section R902.1.2, or a Class C roof covering complying with CRC Section R902.1.3 is required, provided installation is in accordance with the master report and the additional requirements of Section R905.3 of the CRC.
The roof tiles may be used in the construction of new buildings located in any Wildland–Urban Interface Fire Area, provided installation is also in accordance with the master report and the additional requirements of Sections R327.1.3.1 and R327.5 of the CRC.
The products recognized in this supplement have not been evaluated for compliance with the International Wildland–Urban Interface Code®.
This supplement expires concurrently with the master report reissued July 2013, revised April 2014.
*Revised April 2014
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2014 Page 1 of 1 1000
ICC-ES Evaluation Report ESR-1647 FBC Supplement* Reissued July 2013 This report is subject to renewal August 1, 2015.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ®
DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 32 16—Concrete Roof Tiles REPORT HOLDER: BORAL ROOFING 7575 IRVINE CENTER DRIVE, SUITE 100 IRVINE, CALIFORNIA 92618 (949) 756-1605 www.boralna.com [email protected] EVALUATION SUBJECT: CONCRETE ROOF TILES: ATLANTIS, BARCELONA 900, BARCELONA—IMPACT, CAPRI, CEDARLITE / CEDARLITE 600, CLASSIC 100, ESPANA / BARCELONA, ESPANA 600, HOMESTEAD SHAKE, HOMESTEAD–SLATE, MADERA, MADERA 700, MISSION S / BARCELONA, ROMA, SAXONY, SAXONY 600, SAXONY 700, SAXONY 900, SAXONY–SHAKE, SAXONY–SLATE, SAXONY–COUNTRY SLATE, SAXONY–SPLIT SHAKE, SAXONY–SPLIT SLATE, SAXONY–IMPACT, SAXONY 900–IMPACT, SPANISH “S” , SPANISH “S” NUEVO, TEJAS ESPANA, VANGUARD ROLL, VILLA, VILLA 600, VILLA 900 AND VILLA 900–IMPACT 1.0 EVALUATION SCOPE
Compliance with the following codes: 2010 Florida Building Code—Building 2010 Florida Building Code—Residential Properties evaluated: Fire classification Weather resistance
Wind uplift resistance 2.0 PURPOSE OF THIS SUPPLEMENT
This supplement is issued to indicate that the Concrete Roof Tiles described in the master report ESR-1647 comply with the 2010 Florida Building Code—Building and the 2010 Florida Building Code–Residential, when designed and installed in accordance with the master evaluation report under this additional condition: The Boral Roofing extruded concrete roof tiles must be installed in accordance with the recommendations of the FRSA/TRI 07320 Installation Manual.
Use of the concrete roof tiles described in the master evaluation report for compliance with the High Velocity Hurricane Zone provisions of the 2010 Florida Building Code–Building, and the 2010 Florida Building Code–Residential has not been evaluated, and is outside the scope of this supplement.
For products falling under Florida Rule 9B-72, verification that the report holder’s quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission).
This supplement expires concurrently with the master report reissued July 2013, revised April 2014.
*Revised April 2014