icans-xviii a position sensitive transmission detector for epithermal neutron imaging e. m....

25
ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Upload: jason-smith

Post on 27-Mar-2015

217 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

ICANS-XVIII

A position sensitive transmission detector for epithermal neutron

imaging

E. M. Schooneveldand

Ancient Charm partners

Page 2: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Content

∙ Introduction

∙ Principle

∙ Construction

∙ Measurements

∙ Conclusions

∙ Future

Page 3: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Introduction

∙ ANCIENT CHARM

∙ EU funded FP6 project, contract 015311

∙ Goal: 3D imaging of cultural heritage (archaeological) objects.

∙ Archaeologists want to know elemental and phase composition of object.

∙ Want to look inside object imaging

Page 4: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

∙ Available techniques

∙ Phase, structure texture analysis:

– Neutron diffraction.

∙ Element analysis:

– Delayed Gamma Activation Analysis

(DGAA)

– Prompt Gamma Activation Analysis

(PGAA)

– Neutron Resonant Capture Analysis

(NRCA)

Introduction

Page 5: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Introduction

∙ Imaging techniques:

– Neutron tomography (NT)

– Neutron diffraction tomography (NDT)

– Prompt Gamma Neutron Activation Imaging

(PGAI)

– Neutron Resonance Capture Imaging (NRCI)

– Neutron Resonance Transmission (NRT)

∙ Our detector transmission neutron detector NRT

Page 6: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Introduction

∙ Pros:

Native imaging (2D detector) no scanning pencil

beam

“4 solid angle coverage”

Elemental analysis

Structural analysis ?

∙ Cons:

Small dips on high baseline need good statistics +

good baseline estimation

Position resolution limited to ~1mm

Need low beam divergence or detector close to sample

Page 7: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Principle

Neutron Detector beam

∙ Estimated data collection time: ~1 hr per 2D image ~1 day per tomograph.

Page 8: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Principle

∙ Element identification by resonant neutron absorption.

∙ Need resonance in right energy range

Neutron absorption resonances of Zn

Neutron energy (eV)

0 200 400 600 800 1000

Cro

ss-s

ecti

on

(B

arn

s)

0

20

40

60

80

100

120

140

Page 9: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

H

Li Be

Na Mg

K

Rb

Cs

Ca Sc V Cr Mn Ti Fe Co Ni Cu Zn

He

B C N O F Ne

Al Si P S Cl Ar

Ga Ge As Se Br Kr

Sr Y Zr Nb Mo (Tc) Ru Rh Pd Ag Cd In Sn Sb Te I Xe

Ba La-Lu Hf Ta W Re Os Ir Pt Au Hg Tl Pb Bi (Po) (At) (Rn)

(Ac- Lr)

<10 eV

10 - 100 eV

100 - 1000 eV

1000 - 10000 eV

10000 - 100000 eV

La Ce Pr Nd (Pm) Sm Eu Gd Tb Dy Ho Er Tm Yb Lu

Th U (Pa) (Ac) (Np) (Pu)

Lanthanides (Rare Earth elements)

Actinides

(Fr) (Ra) noble gasses

∙ Periodic system with indications for suitability of NRT

(regions were lowest resonance occurs)

Principle

Page 10: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Construction

∙ Detector

16 channel PMT

Optical fibres(4 per pixel)

GS20 glass scintillators1.8mm * 1.8mm * 9mm

∙ Pixels: 4 * 4 array with 2.5mm pitch 10mm * 10mm active area.

∙ Made 16 pixel prototype to get experience with assembly and test performance.

Page 11: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Construction

∙ Monte Carlo simulations (GEANT4)

∙ Issues: Type of optical fibre + scintillator support.

∙ Cross-talk:Fibres Support Total cross-talk (%)

- Quartz Quartz Plastic Plastic

Al Al

BoronNitride Al

BoronNitride

12.5 19.4 18.2 28.9 18.3

Made prototype with plastic fibres and BN scintillator support.

Page 12: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Construction

∙ Photos

Page 13: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Construction

Page 14: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Measurements

∙ Measurements on INES beam line at ISIS

∙ DISCLAIMER: Measurements mainly done to examine detector performance (not to demonstrate technique)

∙ Measured a few archaeological objects, but no imaging

∙ Software for composition analysis and image reconstruction not ready yet.

∙ Not enough timing resolution yet.

Page 15: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

No sample (one pixel)

Neutron energy (eV)

1000.0 65.0 29.3 16.6 10.7 7.5 5.5 4.2 3.3 2.7

Co

un

t ra

te (

kHz)

0.0

200.0

400.0

600.0

800.0

TOF (s)

0 100 200 300 400 500 600 700 800 900 1000

Measurements

∙ Basic properties

Useful energy region: up to ~1 keV

Count rate (per pixel): ~200 kHz (5% dead time)

Page 16: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Measurements

Cross-talk measurement, using a big 20 m thick gold foil with one 2.5*2.5mm hole lined up with a pixel

Neutron energy (eV)

4.0 4.5 5.0 5.5 6.0

Co

un

t ra

te (

A.U

.)

0.0

5.0e+5

1.0e+6

1.5e+6

2.0e+6

2.5e+6

3.0e+6

pixel with goldpixel with hole

∙ “Big” gold foil with 2.5mm hole.

∙ No dip for pixel with hole low cross-talk

As MC predicted plastic fibres no problem

Page 17: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Measurements

∙ Bronze sheet (90.5% Cu , 8.49% Sn, 0.088% Ag)

∙ Good agreement

∙ Missing peaks, mainly Iodine (upstream in beam)

Measured absorption spectrum of bronze sample

Neutron energy (eV)

0 10 20 30 40 50 60 70 80 90 100

Ab

sorp

tio

n

0.00

0.05

0.10

0.15

0.20

0.25

0.30

measuredtheory

Page 18: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Measurements

∙ Agreement less good.

∙ Still good for imaging

Measured absorption spectrum of bronze sample

Neutron energy (eV)

200 400 600 800 1000

Ab

sorp

tio

n

0.0

0.2

0.4

0.6

0.8 measuredtheory

Page 19: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Measurements

∙ Very corroded could not measure tin with diffraction.

∙ Piece of bronze vase from Villa Giulia

Page 20: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Measurements

No problem to see tin resonances.

Corroded piece of a vase from Villa Giulia.

Neutron energy (eV)

100 150 200 250 300 350 400

Ab

sorp

tio

n

-0.01

0.00

0.01

0.02

0.03

0.04

Tin Copper

Page 21: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Measurements

∙ ANCIENT CHARM black box

Black box Al 9.

TOF (s)

100 200 300 400 500 600 700 800 900 1000

Co

un

t ra

te (

A.U

.)

0.0

1.0e+4

2.0e+4

3.0e+4

4.0e+4

∙ Diffraction: lot of incoherent scattering

∙ Neutron radiography: low penetration

lot of H}

∙ NRT : much higher penetration of high energy neutrons

hydrogen moderates neutrons peaks broader

Page 22: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Measurements

Theoretical absorption of 1cm thick silver

Neutron energy (eV)

10 20 30 40 50 60 70 80 90 100

Ab

sorp

tio

n

0.0

0.2

0.4

0.6

0.8

1.0

1.2

Black box Al 9. Spectrum of spot 2

Neutron energy (eV)

10 20 30 40 50 60 70 80 90 100

Ab

sorp

tio

n

-0.1

0.0

0.1

0.1

0.2

0.2

0.3

∙ All peaks about same height thick silver (~1 cm )

∙ Peak amplitudes << 1 background from moderated neutrons.

∙ Peak shape correct still able to identify elements

Black box contains silver object, probably also hydrogen !!

-0.05

0.00

0.10

0.05

0.15

0.20

0.25

Page 23: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Conclusion

Successfully built 16 pixel prototype transmission detector.

Detector performed very well: Low cross-talk,

high rate

capability,

acceptable energy range.

Successful NRT tests.We are very happy with the detector.

Page 24: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

Diffraction from bronze sample

Neutron wavelength (Å)

0.5 1.0 1.5 2.0 2.5 3.0

No

rmal

ised

co

un

ts

0.75

0.80

0.85

0.90

0.95

1.00

1.05

1.10

Future

∙ 100 pixel detector integrated with goniometer

∙ Imaging

∙ Diffraction

Page 25: ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

The end

∙THANK YOU ∙