ibm solutions for engineering analysisibm solutions for...

19
IBM Solutions for Engineering Analysis IBM Solutions for Engineering Analysis Supporting MSC Software David Coutts, DE & STG Industrial Sector CTO, IBM Systems & Technology Group Teri Dewalt, Deep Computing Market Manager, IBM Systems & Technology Group

Upload: dangtram

Post on 16-Mar-2018

222 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

IBM Solutions for Engineering AnalysisIBM Solutions for Engineering Analysis Supporting MSC Software

David Coutts, DE & STG Industrial Sector CTO, IBM Systems & Technology Groupp

Teri Dewalt, Deep Computing Market Manager, IBM Systems & Technology Group

Page 2: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

Agenda• Partnership focus since 2006

• IBM Infrastructure for Engineering Analysis– Component areas

• HPC offerings for CAE solvers• Virtual servers for Simulation Data Management• User/client access• Global file system and scalable shared storage

– Operational Modelp• Direct client Access

• Computing on Demand and MSC

• Conclusion

2

Page 3: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

Large Ship Model & BMW “Model of the Day ft T ”after Tomorrow”

• Hardware– IBM p6-550 4.7GHz POWER6 8-way system

with 64GB memory 24 discs

• Hardware– IBM p5-595 2.3GHz POWER5+ 64-way system

with 512GB memory– Filesystem: 48-way striped 146GB 15Krpm

driveswith 64GB memory, 24 discs• Model

– 1.4M elements, 8.5MDOF• Software

– MSC Nastran V2007r1M 6 b d 4 4 i 6 b

drives• Model

– 151M grid points– 95M hexa elements– 911M global DOF

• reduces to 455M equations• Mem=6gb dmp=4 smp=4 mio=6gb

mode=i8• Analysis

– 15,000 modes under 62Hz (ACMS)– 4.7 hours

q

• Software– MD Nastran R2 (ILP64 version)

• Analysis– 22.3 hours (1 CPU) for 149 iterations– Scratch space 2.3 TBp– 100GB binary output file

Contact: Martin Feyereisen, Ph.D.,IBM Deep Computing ([email protected])

3

www.mscsoftware.com/press/assets/Largest_FE_Modell_at_BMW.pdf

Page 4: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

iDataplex for HPC Cluster Needs• The iDataplex rack structure is optimized for datacenter cooling efficiency,The iDataplex rack structure is optimized for datacenter cooling efficiency,

density and deployment flexibility– Ease of use:

• all service and cabling from the front– High Density:

• 84U of server and storage chassis and• 84U of server and storage chassis and • 16U of switch and PDU space

– Half-depth rack optimizes airflow path for maximum cooling– Optional Rear Door Heat Exchanger

• 2.4X the density of traditional ‘1U’• significant energy reduction in cooling (typically 40%)

– New dx360 M2 nodes – Intel 5500 Quad Core Processors• 2 socket up to 95W processors• 16 DIMMs (up to 128GB)• Dense compute, Storage, I/O configurations

REAR CABLE AREA

Optional Rear Door Heat Exchanger

p , g , g

Cold Isle

iDataPlex

Cold Isle

Hot Aisle

StdRack

w/ 1U’s

StdRack

w/ 1U’s

Sized by 400 CFM floor tiles

Hot AisleHot Aisle

4

Page 5: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

Virtual Servers for Simulation Data Management

MSC SimManager running on the IBM Blue Stack. D t ti i d

4 to 8w SMP(like p560, p570)

1. Virtualized Server

SimManagerSimManagerHA &Demonstrating improved:

– Agility

– Availability

Manageability oxy

+ N

D

B2

HAD

R

VIO

S

WA

S

WA

S

ggHA &

ScalabilityW

AS

– Manageability

– Security

– Energy Efficiency

SOFS clustereNet adapt

Pro DB

p560DB2 table

spaces

S O ti

Targeting Medium to Large Enterprise Deployments

SAN

LAN

2. Global File System,

Single Name Space

SoFSSoFS SoFS

Server Options:• POWER Systems• Modular/Blade Systems

Fibre Channel

WAS Trans-action Logs

File Storage B

oot

Imag

es

BBBB

Recov Logs

IBM Total Storage DS4800

Scratch Storage

• Hybrid of the above3. Shared Remote Storage

g B

5

Page 6: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

POWER6 Enhanced Server Virtualization Value for SimManager

Live Partition Mobility

August, 2008 - Demonstrated Live Partition Mobility for MSC SimManager @ IBM Innovation Center, San Mateo, CA

Live Partition MobilityMove an entire Logical Partition from one system to another while it is

i ith l t

Live Partition Mobility

running with almost no impact to end users(AIX 5.3 and later)

Virtualized SAN and Network Infrastructure

Advantages (attributes of Dynamic Infrastructure):Advantages (attributes of Dynamic Infrastructure):• Energy Savings during non-peak hours by consolidating workloads and powering off excess

servers

• Workload movement to a different server with no loss of service

• Continuous Application Availability through planned outages for hardware and firmware maintenance

• Workload Balancing as computing needs spike by redistributing workloads onto multiple physical• Workload Balancing as computing needs spike by redistributing workloads onto multiple physical servers without service interruption

6

Page 7: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

SimManager Clients HTTP

NFS/FTP/…Script RPC

• Interactive Clients:

SimManager supports multiple clientsScript-RPC

Interactive Clients:– Web / browser based– Application based – by leveraging the features of the

SimManager Integrated Client library, applications can

Web browser

g g y, ppcommunicate and interact with the SimManager infrastructure.

SM API

SM Web Service LSF

SM Remote Clients

HPC

AIX

AIX

• Batch clients:– HPC Cluster(s)

7

AIX

Page 8: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

Scale Out File Services (SOFS) CommonInternet Fil S tChallenges for Virtual Product Dev

• Store and manage increasing amounts of data• Access and share data across multiple sites• Manage the content across its lifecycle NFS

Windows®

clientScale Out File

File System

(CIFS)

• Manage the content across its lifecycle.

SOFS addresses these requirements and moreSOFS is ideally positioned as a common storage

UNIX®/Linux®

client

NFSFile Services

cluster

FTPy p gsystem for all PLM components

Solution Background• SOFS provides a cluster based global file system that

Web browserclient

HTTPIBM Tivoli®Storage Manager

FTP

HPC Cluster (client)

CIFSCIFS

IBMIBMProvisioningProvisioning

NFSv3NFSv3 HTTPSHTTPS FTPFTPCTDBCTDB

HSM - ArchivingHSM - ArchivingView

p g y–Scales to very large numbers of nodes (at each site)–Provides a high performance CIFS and NFS front-end–Supports highly availability and business continuity–Includes integrated management and deployment

HPC Cluster (client)

IBMGPFS

3.2

IBMGPFS

3.2

Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 5 IBM BladeCenter clusterIBM BladeCenter cluster

ReportingReporting

MonitoringMonitoringTSMBackup & Restore

TSMBackup & Restore

IBM DirectorHdwr Mgmt

IBM DirectorHdwr Mgmt

Com

pone

nt Includes integrated management and deployment

assists.–overcomes current filer-based NAS solution limits

• The current solution is GTS led with tiers of assistance IBM BladeCenter clusterIBM BladeCenter cluster

IBM DiskIBM DiskIBM TapeIBM Tape

Cfor installation and operation.

8

Page 9: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

How can SimManager leverage SoFS?U S FS ifi d t i f t t f E i i A l iUse SoFS as a unified storage infrastructure for Engineering Analysis

– Configure local vaults in SoFS for site deployments– Exploit direct access to the vault and manipulate files directly with speed and efficiency – as

permitted by SimManager for clients (in addition to itself)– Cross mount remote file systems and Read Only Cache remote content in SoFS

• Single Site Leverage – highlighting Direct Client Access– Attach all clients, SimManager, and HPC cluster to SoFS in a single namespace– SimManager can determine if local storage is available via Action Runner– SimManager “owns” the data in the vaults. It can add and remove both interactive and batch

clients from access control lists and pass pointers to clients for their data.– SimManager will “rename” result files produced by solver applications such as Nastran to the g p y pp

vault location thus minimizing file movement – Works for all scenarios except Web Client (which must use HTTP access and can not directly

NFS mount the file system)

• Multi Site Leverage:• Multi-Site Leverage:– Configure both sites with SoFS and cross mount file systems– Through a special extension, SoFS supports local Read Only caching (pull) of content from a

remote site.

9

Page 10: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

SoFS Replication and Caching• SoFS supports both Replication (push) and Caching (pull) of File System

Content– Replication Modes

Si l Sit• Single Site• Multiple Sites• Synchronous • Asynchronous

R li t ti h d l• Replicate on creation or upon a schedule

– Read Only Caching (via special extensions)• SoFS is capable of caching remote files and associated metadata in the local (GPFS-

based) file systembased) file system– Files accessed by multiple remote users would be transferred via WAN only once– Directory and attribute caching significantly reduces WAN traffic related to accessing directories

and querying file attributes such as owner and size • Replicate content from a remote site based on first “touch” (directory and file content)

at the local site• Or, use a remote (originating) db update event to trigger a pseudo touch from the local

site

Read / Write caching enhancements are in process– Read / Write caching enhancements are in process

10

Page 11: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

Engineering Analysis Operational Model HTTP

JDBC

Script-RPCScript RPCNFS/FTP/…

SoFS

- Featuring Scale out File Services & Direct Client Access for SimManager, HPC Cluster(s), and Interactive Users

SoFS Single site and multi-site leverage

DB(Metadata)

Global Vault

WAS cluster & DB2

SoFSWeb browser

I d Fil

g

LocalDataVault

WorkloadManagement

Improved File Transfer

performance

HPCFiles

Security: identity and access management

SM API

SM Web Service

LSFSM Remote Clients

HPCFiles

RemoteDataVault

SimManager to HPC cluster interaction: Workload / job control

Service

AIX

RemoteRO Vault

CacheAIX Vault

HPC + SimManager Storage Synergy

AIX

11

Page 12: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

IBM® Computing on Demand (CoD)Tap into IBM CoD centers on a flexible and secure basis

– Dedicated (yearly commitment) Infrastructure-as-a-Service

– Variable (weekly commitment)– Dynamic (hourly commitment)

in collaboration with Intel®

L C iLarge Capacity– Over 13,000 processors, 56 TB storage– Intel® Xeon ®, AMD Opteron™,

IBM Power™

Global Reach– US, Canada, Europe, Japan

Test drive CoD today!Test drive CoD today!– IBM System x™ 16 node cluster – Linux® or Windows® HPC Server 2008– http://www.ibm.com/deepcomputing/tesp p p g

tdrive

12

Page 13: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

IBM CoD partner solution: MD on Demand“Now you can access the powerful MD Nastran simulation suite on demand in the IBM CoD center. Gain access, when you need it, to multi-discipline analysis tools.”

- Frank Kovacs, MSC.Software, VP strategic partnerships MD NastranMD on Demand

• Requirement– Turnkey solution for on demand CAE

Enterprise application provider CoD

MD Nastran

– Reliable, large scale compute clusters on short notice

– Competitive, Secure, Scalable infrastructure

S l ti• Solution– IBM CoD membership and capacity rental– Optimized on System p or System x systems– MD Nastran multi-discipline simulation suite

Trial Offer*IBM CoD membership

5 day IBM System p5 POC p• Short-term licensing • Unlimited use for subscribed period

– MSC.Software and IBM Technical assistance• Project planning

y y p(on 8, 16 or 32 processors)

5 day MSC.Software MD Nastran licenses with multi-run lease

Pricing: $11K $13K $16KProject planning• Optional value added services *limited time only, subject to availability

Pricing: $11K, $13K, $16K

13

Page 14: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

Conclusion

• Globalization and the current economic environment are forcing clients to rethink their IT infrastructure requirements

• IBM has the technologies to evolve your IT infrastructure for Engineering Analysis into Dynamic Infrastructure– IBM High Performance Computing offerings such as iDataplex, e1350 clusters, g p g g p

and Power 575 for engineering analysis applications– IBM “Blue Stack” supporting SimManager for improved scalability, availability

and manageability. – IBM Scale out File Services enables Engineering Analysis data to be shared

locally and globally with the performance, availability and reliability required.

• MD on Demand – rental of MD Nastran and IBM systems in IBM Computing on Demand cloud centers – to supplement or transform your Engineering Analysis environment.

14

Page 15: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

Contact Details :• For further information please contact

David H. CouttsIBM

Teri DewaltIBMIBM

2455 South RoadPoughkeepsie, NY12601

IBM

11400 BURNET RDAustin, TX78758 349312601

USA

(845) 435-6484tt 1@ ib

78758-3493USA

(512) 331-8323td lt@ [email protected]

• Websites– Ibm.com/deepcomputing

[email protected]

p p g– Ibm.com/deepcomputing/cod– Ibm.com/solutions/plm Thank You!

15

Page 16: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

BackupBackup

Page 17: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

Entry, Medium and Large SoFS Configurations (BladeCenter based)

3 I/O Nodes 1 Management 6 I/O Nodes 1 Management Node • 13 I/O Nodes 1 Management• 3 I/O Nodes, 1 Management Node

• DS3400 with up to 27 TB usable capacity

• Streaming performance with large blocks up to 700 MB/s

• 6 I/O Nodes, 1 Management Node• 2*DS4700 with up to 132 TB

usable capacity• Streaming performance with large

blocks up to 1500 MB/s• Up to 15000 active concurrent

• 13 I/O Nodes, 1 Management Node

• 4*DS4800 with up to 528 TB usable capacity

• Streaming performance with large blocks up to 4000 MB/sblocks up to 700 MB/s

• Up to 7500 active concurrent users

Clientnetwork

ClientnetworkClient

network

• Up to 15000 active concurrent users

blocks up to 4000 MB/s• Up to 30000 active concurrent

users

So

So

So

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS M AM

Ethernet Switch Module

Midplane

Ethernet Switch Module

et o

BladeC

e

SoFS

SoFS

SoFS

SoFS

SoFS

SoFS

SoFS

SoFS

SoFS

SoFS

SoFS

SoFS

SoFS

Mgt

AM

M

Ethernet Switch Module

Midplane

Ethernet Switch Module

BladeC

enteSo

So

So

So

So

So

HS

HS

HS

HS

HS

HS

HS M AM

Ethernet Switch Module

Midplane

Ethernet Switch Module

BladeC

e

Midplane

oFS B

ladeoFS

Blade

oFS B

ladeS

21 Blade

S21 B

ladeS

21 Blade

S21 B

ladeS

21 Blade

S21 B

ladeS

21 Blade

S21 B

ladeS

21 Blade

S21 B

ladeM

gt. Blade

MM

AM

M

FC Switch Module FC Switch Module

enter H C

hassis

Midplane

S B

ladeS

Blade

S B

ladeS

Blade

S B

ladeS

Blade

S B

ladeS

Blade

S B

ladeS

Blade

S B

ladeS

Blade

S B

ladet. B

ladeM

AM

M

er H C

hassis

FC Switch Module FC Switch Module

External FC Switch

Midplane

oFS B

ladeoFS

Blade

oFS B

ladeoFS

Blade

oFS B

ladeoFS

Blade

S21 B

ladeS

21 Blade

S21 B

ladeS

21 Blade

S21 B

ladeS

21 Blade

S21 B

ladeM

gt. BladeM

MA

MM

nter H C

hassis

FC Switch Module FC Switch Module

DS 3400

EXP 3000

EXP 3000

EXP 810

DS 4800

EXP 810EXP 810EXP 810EXP 810EXP 810EXP 810EXP 810

EXP 810

DS 4800

EXP 810EXP 810EXP 810EXP 810EXP 810EXP 810EXP 810

...

DS 4700

EXP 810EXP 810EXP 810

DS 4700

EXP 810EXP 810EXP 810

17

EXP 3000

EXP 3000

EXP 810EXP 810EXP 810EXP 810EXP 810EXP 810

EXP 810EXP 810EXP 810EXP 810EXP 810EXP 810

EXP 810EXP 810EXP 810

EXP 810EXP 810EXP 810

17

Page 18: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

SimManager Multi-Site Environment

SMweb-client

“Asia” “US”SMweb-client

ApplicationStandard (meta-data)Communication (WebServices)

SM-IC

launch

Web Server Trigger code for file cachingN

Batch client- Nastran

SimManager

SM clientdirect vault access

DB2

for file caching

SoFS Server AsiaW

AN

Batch client

Asia1vault

Asia2vault

So S Se e s a

SoFS Server USTrigger cache of file from Asia

vaultvaultUS1vault

Asia2vault cache

Asia1vault cache

SoFS with Replicate at create for Asia1

SoFS with ReplicationSoFS with Replication on first touch for Asia2

18

Page 19: IBM Solutions for Engineering AnalysisIBM Solutions for ...web.mscsoftware.com/events/vpd2009/na/presentations/61-IBM_Coutt… · • all service and cabling from the front ... •

MSC.Software Confidential

IBM Computing on Demand (CoD) – Infrastructure-as-a-Service

Computing on Demand Base Access One year annual membership Server management nodeVirtual Private Network (VPN) access

Computing on Demand Capacity Models

Client scheduling GUI

Computing on Demand Capacity Models Dedicated

– Dedicated resources: 1-3 year commitment

– Custom Environment – choice of data

Variable / Dynamic– Reserve by the week/hour– “Pay for use”– Utilize CoD Cloud infrastructure

(Click to Enlarge in Screen Show)

center, servers, storage, dedicated switch, WAN/LAN high availability network, add-on services

– Leased by IBM Global Financing

– Highly-secure, virtual clusters dedicated to one client at a time

– Automated network and server provisioning

CoD Cloud CentersNew York (POK)

– 7,000 CPU’s (System x, System p)London

Tokyo– 200 CPU’s (System x)

Future locations based on c stomer need

– 7,800 CPU’s (System x); dedicated onlycustomer need

19