IAGOS-RH/T Measurements: Update on QA Efforts

www.iagos.org

Herman Smit, Susanne Rohs and Patrick Neis Forschungszentrum Jülich GmbH [email protected]

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM 10 Annual Meeting 23 27 April 2018 Potsdam Germany

Page 2: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

IAGOS - CORE Flight Map

IAGOS-CORE aircraft schedule: • In 2017/2018, 9 equipped aircraft in regular

operation. Planned 15 A/C’s in 2020 • Approx. 500 flights per aircraft per year • More than 200 airports worldwide visited regularly

http://www.iagos.fr

New 2017/2018: CAL#2, AF#2, HAL & Finnair

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Page 3: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

In inlet strong speed reduction (Mach≈0.8 to 0) with adiabatic conversion: Heating (SAT to TAT) : in UT ≈ 30oC Compression (PS to PD): in UT ≈ Factor 1.6

RH at detector (RHD) more than factor 10 smaller than RH sampled air (RHS)

IAGOS & MOZAIC: RH,T Sensor in TAT-Inlet

Rosemount (102BX) TAT-Inlet System

H 2 O -S e n s o r

AIRCRAFTSKIN

SENSORSRH: HUMICAP-HT : PT100

DEICINGHEATER

BOUNDARY LAYERSCONTROL HOLES

RIGHT ANGLEPRODUCESPARTICLE

SEPARATION

TAT, RHD

SAT

RHD

H 2 O -S e n s o r

AIRCRAFTSKIN

SENSORSRH: HUMICAP-HT : PT100

DEICINGHEATER

BOUNDARY LAYERSCONTROL HOLES

RIGHT ANGLEPRODUCESPARTICLE

SEPARATION

H 2 O -S e n s o r

AIRCRAFTSKIN

SENSORSRH: HUMICAP-HT : PT100

DEICINGHEATER

BOUNDARY LAYERSCONTROL HOLES

RIGHT ANGLEPRODUCESPARTICLE

SEPARATION

TAT, RHD

SAT

RHDS S S

HMT 330/Vaisala Humicap/PT100

Sensor Carrier (Enviscope, Germany)

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Page 4: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

RHCal(Ti) =a(Ti) + b(Ti) x RHUnCal(Ti)

Regular calibration (every 1000 flight hours in the ESF (Env.Sim.Fac.) at Juelich, Germany

Since 2016, against MBW 373 LX Cryo-genic Frostpoint Hygrometer. Before Lyman(α)-fluorescence hygrometer at TAir <-10 oC and Frost-point hygrometer at TAir>-10 oC with relative uncertainty better than 5%

Under realistic „flight“ conditions of humidity, temperature and pressure

IAGOS & MOZAIC Capacitive Hygrometer (MCH & ICH): Pre- & Post-Flight Calibration

-10 -5 0 5 10 15 20 25RHUnCal [%]

-5

0

5

10

15

20

RH

Cal

[%

]

T = -38.7 °CT = -28.5 °CT = -19.7 °CT = 1.3 °CT = 21.0 °C

Smit: IAGOS-H2O & its QA Efforts GRUAN ICM#09 Annual Meeting ,12-16 June 2017, Helsinki Finland

Page 5: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

Horizontal resolution

Relative Humidity: ΔX ≅ Aircraft speed x Response time ΔX ≅ 15 km @ Z ≅ 8-12 km cruise altitude

Precision Relative Humidity: ± (1-2)% RH @ Z=0-8 km ± (2-4)% RH @ Z= 8-12 km Temperature ± (0.1-0.2) K @ Z= 0-12 km

Uncertainty Relative Humidity: ± (5-6)% RH @ Z= 0-12 km Temperature: ± (0.5-1.0) K @ Z= 0-12 km

MOZAIC-Humidity Device: Performance

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Page 6: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

HIGHLIGHTS : UTLS TEMPERATURE AND CLOUDS

20 years of temperature measurements in the tropopause region indicate: De-seasonalized time series show:

⇒ no significant trends in the UTLS. This contradicts +0.56 K/decade predicted

by ERA 40. ⇒ Details: Berkes et al., ACP 2017

Temperature Trends Cirrus Clouds

2.0 1.5 1.0 0.5 0.0

RH

ice

[1]

2.0 1.5 1.0 0.5 0.0

RH

ice

[1]

Observation of clouds and water vapour provide new insights in cirrus properties: Probability of higher dynamic equilibrium

RHice correlates with higher Nice. Thin cirrus (Nice < 0.1 cm-3) dominate cirrus

at mid-latitudes. ⇒ Details: Petzold et al., Farad. Discuss. 2017

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Page 7: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

Time series of IAGOS water vapour in the UTLS over the North Atlantic (40-60 oN, LS: PV>2.0 pvu & UT: PV < 2.0 pvu)

P. Neis, PhD Thesis, 2017

IAGOS-RH : TRENDS

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Page 8: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

De-seasonalized time series of IAGOS water vapour in the UTLS over the North Atlantic (40-60 oN, LS: PV>2.0 pvu & UT: PV < 2.0 pvu)

P. Neis, PhD Thesis, 2017

IAGOS-RH : TRENDS

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Page 9: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

IAGOS-RH/T: WATER VAPOR & TEMPERATURE TRENDS

RHice H2O VMR

Estimated Trend from Obs. 0.0 %/year 0.04 %/year

ϬN 11.6 % 17.5 %

ΦN 0.26 0.29

n* (Ѡ0 = 0.5 %/year) 21.5 28.9

n* (Ѡ0 = 1 %/year) 13.5 18.2

Estimation of numbers of years needed to detect a trend: 95 % confidence level, 90 % probability (Wheatherhead et al., 1998; Whiteman et al., 2011)

n* is the number of years to detect a trend, Ѡ0 is the specified trend magnitude (% year−1), ϬN is the standard deviation of the total noise in the time series (% of mean value), and ΦN is the autocorrelation of the noise.

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Page 10: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

High Natural Variability of Water Vaour in UT

High natural variability of H2O, already: • > 20 % over distance of 100 km • > 10 % over distance of 20 km • < 1% over distance < 1 km

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Source: Offermann et al., JGR, 2002

Page 11: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

MOZAIC-Humidity Device (MHD): Application of In-Flight Calibration (IFC)

Based on the technology and experience obtained during more than one decade of MOZAIC-RH/T operation.

Long-term zero drift of MOZAIC-device, particularly at low temperatures, is the critical and accuracy determining parameter

In-Flight determination of long term zero drift during dry stratospheric episodes as a function of temperature (RH0(T) at 5ppmv water vapor).

Correction of zero drift of RH-measurements Re-analysis of RH-Data in 2017/2018: Application of

IFC on 20 years of MOZAIC-RH measurements

[Smit et al., J.Atm.Ocean.Tech., 2008]

Page 12: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

2017/2018: Re-Analyis of 20 years of MOZAIC-Relative Humidity Measurements:

Application of In-Flight Calibration (IFC) After:

(Neis-Rohs-Smit) Before:

(Smit et al., 2014))

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Page 13: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

ALL

Day

Night

MOZAIC Versus Radiosondes: Comparison RH at PBL Study by Herve Petitin, Submitted to ACPD , April 2018

Above PBL Day+Night IAGOS: 55-60% RS: 45-55%

Above PBL at Day IAGOS: 55-60% RS: 45-55%

Above PBL at Night IAGOS: 50-60% RS: 60-70%

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Page 14: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

File : DENCHAR-WVSS-LICC-141010-StdPlot-TFR-A1.GRF

0

200

400

600

800

1000

Pre

ssur

e [h

Pa]

200

220

240

260

280

300

Tem

pera

ture

[K]

9 10 11 12 13 14 15 16 17 18 19Day Time (Hours)

Ly_PairLy_TUmlLy_TPrRLy_AFLTFR_Ref1WVSS_TFR

DENCHAR-WVSS: LICC 2010 Performance WVSS versus ESF at Jülich DD. 14.October 2010: Comparison with Ly (α) Hygrometer , Dew Point Hygrometer (Gen.Eastern) and Humicap (Vaisala)

Frost Point Temp.'s

DENCHAR-LICC 2010: WVSS-II @ ESF Perfomance P,T,H2O: 14 Oct.2010

15 Smit: IAGOS-H2O & its QA Efforts

GRUAN ICM#09 Annual Meeting ,12-16 June 2017, Helsinki Finland

Red=Reference Tfrost

Green=Pressure

Blue = Air Temp.

Page 15: IAGOS-RH/T Measurements: Update on QA Efforts · 2019-11-28 · IAGOS-RH/T Measurements: Update on QA Efforts Herman Smit, Susanne Rohs and Patrick Neis . Forschungszentrum Jülich

Smit: IAGOS-RH/T Measurements: An Update on QA-Efforts GRUAN ICM-10 Annual Meeting ,23-27 April 2018, Potsdam, Germany

Suggestions of Performance/Validation Studies or Intercomparisons of Different Hygrometers to be done in the ESF (Env.Sim.Facility at Jülich) in the

scope of GRUAN or NDACC

1. CFH versus FPH against MBW 373 or other Hygrometer

2. New Instruments

Advantage ESF: Entire sonde package under realistic atmospheric pressure, temperature, and humidity conditions

Time schedule: 2019-2020

Any Interest from GRUAN ?