Overview In order to o btain the surface stiffness and internal flexibility of various mechanical components used in automobiles, aircraft, ships, building materials, machine tools, and other items, a heat treatment called carburization is applied in which the amount of carbon in the surface coat is increased, and only the surface coat is quench harden ed. The choice of solid carbu rizing, liquid carburizing, gas carburizing, vacuum carburizing, and other techniques is made according to factors including production volume, size of equipment and facilities, and necessity of automation. However, there is a trend toward gas carburization because adjustment of the degree of carburization is relatively easy , lending itself t o automation and mass production. The CX1000/CX2000 Control and Measurement Station automatically computes the equilibrium carbon concentration (carbon potential, or CP value) of the atmospheric gas carburizing furnace, and maintains the optimal CP value inside the furnace. Customer Needs - T o identify and control the carb on potential in real time, avoid excess carburizing, and increase quality. - T o lower future operating costs by digitally recording the control process and saving the results as quality data thereby reducing man hours on maintenance of spare parts. - T o achieve such CP con trol and digital recording in a simple and high cost-performing solution. Process Outline It is not possible to directly measure and control the carbon potential (CP) inside an atmospheric gas carburization furnace. Therefore, adjustment of the furnace atmosphere used to be performed by simply using a dew cell dew point indicator. To gain the advantages of sensitivity and rapid response, the mainstream has more recently adopted infrared gas analyzers for controlling CO 2 levels, and zirconia type O 2 sensors for analyzing O 2 . The CX1000/CX2000 supports both infrared gas analyzers and zirconia type oxygen sensors, and automatically and internally computes the CP value according to the output from those devices. By incorporating this a utomatically calculated CP value into a PID control loop as a process value, real time monitoring, control, and recording of CP values can be performed very easily . Also, pattern control of the intern al temperature of the furnace is necessary in order to correct the temperature rise time according to the acceleration of carburization and wall thickness of the item being processed, as well as perform primary and secondary quenching and annealing after carburization. However, in addition to being able to control multiple loops, a single CX series instrument can control the CP value while performing pattern control of this internal furnace temperature. 1. Example of a Batch-Type Carbonizing Furnace  e r u t a r e p m e T l o r t n o c  l o r t n o c  P C D I P e l p u o c o m r e h T P C D I P e r u s s e r p  l a i t r a p  O C O 2 r o s n e s O C ( 2 ) r e z y l a n a 0 0 0 1 X C computation  The CX1000 has a compact case (144 mm x 144 mm), can control temperature and CP simultaneously , and functions like a paperless data recorder. Y ou can instantl y determine the progress status even when running programs by viewing the PV/SP simultaneous display and time base display. Industry: Machinery, Iron & Steel (Heat Treatment) Product: Control and Measurement Station (CX1000/CX2000) APPLICATION NOTE Control of Carbon P otential in Carbonizing Furnaces All Rights Reserved, Copyright © 20 06, Yokogawa Electric Corporation http://www.yokogawa.com/ns/ AN 04A00P10-01E

Upload: mukesh-mehta

Post on 08-Apr-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: iab-app-carburization-en

8/7/2019 iab-app-carburization-en

http://slidepdf.com/reader/full/iab-app-carburization-en 1/2

OverviewIn order to obtain the surface stiffness and internal flexibility of

various mechanical components used in automobiles, aircraft,ships, building materials, machine tools, and other items, a heattreatment called carburization is applied in which the amountof carbon in the surface coat is increased, and only the surfacecoat is quench hardened. The choice of solid carburizing, liquidcarburizing, gas carburizing, vacuum carburizing, and othertechniques is made according to factors including productionvolume, size of equipment and facilities, and necessity ofautomation. However, there is a trend toward gas carburizationbecause adjustment of the degree of carburization is relativelyeasy, lending itself to automation and mass production. TheCX1000/CX2000 Control and Measurement Station automaticallycomputes the equilibrium carbon concentration (carbonpotential, or CP value) of the atmospheric gas carburizing

furnace, and maintains the optimal CP value inside the furnace.

Customer Needs- To identify and control the carbon potential in real time, avoid

excess carburizing, and increase quality.

- To lower future operating costs by digitally recording thecontrol process and saving the results as quality data therebyreducing man hours on maintenance of spare parts.

- To achieve such CP control and digital recording in a simpleand high cost-performing solution.

Process OutlineIt is not possible to directly measure and control the carbonpotential (CP) inside an atmospheric gas carburization furnace.Therefore, adjustment of the furnace atmosphere used to beperformed by simply using a dew cell dew point indicator. Togain the advantages of sensitivity and rapid response, themainstream has more recently adopted infrared gas analyzersfor controlling CO 2 levels, and zirconia type O 2 sensors foranalyzing O 2.

The CX1000/CX2000 supports both infrared gas analyzers andzirconia type oxygen sensors, and automatically and internallycomputes the CP value according to the output from those

devices. By incorporating this automatically calculated CP valueinto a PID control loop as a process value, real time monitoring,control, and recording of CP values can be performed veryeasily. Also, pattern control of the internal temperature of thefurnace is necessary in order to correct the temperature rise timeaccording to the acceleration of carburization and wall thicknessof the item being processed, as well as perform primary andsecondary quenching and annealing after carburization.However, in addition to being able to control multiple loops,a single CX series instrument can control the CP value whileperforming pattern control of this internal furnace temperature.

1. Example of a Batch-Type Carbonizing Furnace

er utar epmeTlor tnoc

lor tnoc PCDIP

elpuocomr ehT

PC

DIP

er usser p laitr ap OC

O 2 r osnes

OC( 2 )r ezylana

0001XC

computation

The CX1000 has a compact case (144 mm x 144 mm), cancontrol temperature and CP simultaneously, and functions likea paperless data recorder. You can instantly determine theprogress status even when running programs by viewing thePV/SP simultaneous display and time base display.

Industry: Machinery, Iron & Steel (Heat Treatment)Product: Control and Measurement Station (CX1000/CX2000)

APPLICATION NOTE

Control of Carbon Potential in Carbonizing Furnaces

All Rights Reserved, Copyright © 2006, Yokogawa Electric Corporationhttp://www.yokogawa.com/ns/AN 04A00P10-01E

Page 2: iab-app-carburization-en

8/7/2019 iab-app-carburization-en

http://slidepdf.com/reader/full/iab-app-carburization-en 2/2

APPLICATION NOTE

2. Example of Continuous Carbonizing Furnaces

0002XC

DIP

elpuocomr ehT

O2

r osnesPC noitatupmoc

er utar epmeTlor tnoc

lor tnoc PC

DIP

DIP

elpuocomr ehT

O 2 r osnesPC

noitatupmoc

er utar epmeTlor tnoc

lor tnoc PC

DIP

DIP

elpuocomr ehT

O2

r osnesPC

noitatupmoc

er utar epmeTlor tnoc

lor tnoc PC

DIP

1 enoZ

2 enoZ

3 enoZ

The CX2000 enables independent PID control on up to sixloops. The capability of CP computation on all six loops makesit equally applicable for large-scale continuous carbonizingfurnaces. Compact and highly cost-efficient, the CX offers anexcellent solution for multi-loop PID control.

3. Combine an O 2 Sensor and CO 2 Analyzer in One

SystemBoth the CX1000 and CX2000 support zirconia type O 2 sensorsand infrared CO 2 atmospheric gas analyzers. As they can bemixed in a single system, you can display phenomena measuredon both the O 2 sensor and CO 2 analyzer for comparison. Controlis performed with the O 2 sensor since it offers faster responsetime, and confirmation is performed by the CO 2 analyzer, whichis more accurate.

Example of Combined Sensors

O( Vm

2 )r osnes

CT

laitr ap OC( V)er usser p

OC( V 2

)r ezylana

DIP Am 02-4PC

eulaV

PCeulaV

noitatupmoc PCO( 2 )epyt

noitatupmoc PCOC( 2 )epyt

F or co n tro l

F o r

c o n firm a tio n

Yokogawa's SolutionCarbon Potential ComputationFunctionCarbonization Furnace Controllers:CX1000/S35 & CX2000/S35

CX1000/S35• Two-loop controller built in to the 144 mm x 144 mm size case

• Function for running thirty-pattern programs

• Max. eight-point paperless recorder built-in (two points ofcontrol + 6 points for measurement)

CX2000/S35• Max. six-loop controller built in (288 mm x 288 mm)

• CP can be computed and controlled for each zone

• One unit handles multiple CP computations and offers highcost-performance

• Max. twenty-six-point paperless recorder (6 points of control +20 points for measurement)

Paperless recorder function for both the CX1000 andCX2000• Automatically records PV, SP, and OUT

• Recording and real time monitoring of the carbon potential

• Includes CF card memory, Web monitor, FTP, and e-mailfunctions

ConclusionWith its CP value calculation function, the CX1000/CX2000can be applied to a wide variety of applications involvingatmospheric gas carburization, and offers a simple, high cost-performance solution for improving quality and efficiency.Also, digitally recording the control process will yield low costoperation well into the future.

All Rights Reserved, Copyright © 2006, Yokogawa Electric Corporationhttp://www.yokogawa.com/ns/AN 04A00P10-01E