1
G H C A B A B C D E F G H D F i-teamglobal. com E PH PH 45 o Drain and rinse the solution and recovery tanks with fresh water. Remove and open the vacuum Ƕŕ ter, make sure that it is clean inside by blowing it out or hold it under running water. Remove the ēĚǷĚČtor gently from the machine and clean it. Clean the squeegee blade’s rubbers and suction opening with fresh water and a clean cloth. Detach and clean the brushes and also the bottom of the brush-deck, now that it is fully exposed. Recharge the batteries. If the i-mop isn’t used regularly, store the charged batteries in a dry clean place. Check the rubbers on the squeegee blade for damage or wear and tear. Turn them over or replace them entirely when needed. Clean the wheels on the squeegee blade, make sure the bearings aren’t clogged. Unscrew the ǶŕƥĚƑ IJ rom the solution tank and clean it under running water. Clean the exterior of the i-mop with a clean cloth and fresh water. Remove the brushes from the machine and clean the water nozzles at the bottom of the scrub deck. If the i-mop isn’t used regularly, store the charged batteries in a dry clean place. Make sure the batteries are charged monthly. Clean the Ƕŕ ter regularly. Empty the tank before storing it and empty the tank before reǶŕŕĿ ng it. Leave the cap open when storing overnight so the tank can vent. Do not kick the brushdeck down with your feet. Be gentile. Switch off the machine when not in use and when you store it. Do not work without the ǶŕƥĚr. Close the cap of the recoverytank, otherwise there’s no water pick-up. PH between 4 - 9. Temperature max 45 o C / 113 o F. Do not tilt more than 45 o . This can cause permanent damage. Solution tank Recovery tank Battery packs Brushes Squeegee Control panel Vacuum ǶŕƥĚ r 'ĚǷĚČ tor Solution + Scrub Scrub Scrub + Dry Scrub + Solution + Dry Battery Indicator Water Save mode Operation Troubleshooting Fill the solution tank. PH between 4 and 9. Temperature max 45 o C / 113 o F. Select your operating mode Lower the scrub-deck by hand Install the battery packs Install the solution tank Install the recovery tank Maintenance and Care daily weekly monthly The i-mop won’t start Remove the battery packs from the machine. Inspect the connectors on the battery and on the machine for any damage or obstruction. Reinsert the batteries and switch on the machine. Make sure that the batteries are charged, check them on the charger, recharge when needed or grab a freshly charged set. If the problem still exists we recommend to reset the i-mop according to our reset procedure. Poor water recovery Please ensure that you have chosen the right cleaning mode and the vacuum motor is running. Check the recovery tank, when full empty it. Always empty the recovery tank after cleaning or when you’ve used up all the solution in the solution tank. Inspect both the dĚǷĚČƥūƑ and the air Ƕŕ ter, clean when needed. Make sure that the recovery tank is seated correctly on the machine, and the cap is scruwed back on the top of the tank. Inspect the rubbers on the squeegee for any damage or wear and tear and that there is nothing stuck inside the squeegee blade blocking the air Ƿow. Make sure the wheels are clean and that they can turn freely. Detach the vacuum hose from the machine and, check both the hose and the opening on the machine. InsufǶČĿĚŠt water Ƿow or no wîƥĚƑ Ƿow Check if the solution tank is ǶŕŕĚē and seated correctly on the machine. Make sure that the right operating mode is selected. Remove the brushes and check the water nozzles on the scrub deck for any obstructions. Empty the solution tank and check the Ƕŕ ter, make sure that it is clean. If the Ƕŕ ter is dirty, please check that it is cleaned monthly or more often, if required by your circumstances.

Upload: others

Post on 24-May-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: i-mop Wallchart English - Tennant Company€¦ · G H C A B A B C D E F G H D F i-teamglobal.com E PH PH 45o Drain and rinse the solution and recovery tanks with fresh water. Remove

G

H

C

A

B

A

B

C

D

E

F

G

H

D

F

i-teamglobal.com

E

PH

PH45o

Drain and rinse the solution and recovery tanks with fresh water.

Remove and open the vacuum ter, make sure that it is clean inside by blowing it out or hold it under running water. Remove the tor gently from the machine and clean it. Clean the squeegee blade’s rubbers and suction opening with fresh water and a clean cloth.Detach and clean the brushes and also the bottom of the brush-deck, now that it is fully exposed. Recharge the batteries. If the i-mop isn’t used regularly, store the charged batteries in a dry clean place. Check the rubbers on the squeegee blade for damage or wear and tear. Turn them over or replace them entirely when needed. Clean the wheels on the squeegee blade, make sure the bearings aren’t clogged. Unscrew the rom the solution tank and clean it under running water. Clean the exterior of the i-mop with a clean cloth and fresh water. Remove the brushes from the machine and clean the water nozzles at the bottom of the scrub deck.If the i-mop isn’t used regularly, store the charged batteries in a dry clean place. Make sure the batteries are charged monthly.

Clean the ter regularly.

Empty the tank before storing it and empty the tank before re ng it.

Leave the cap open when storing overnight so the tank can vent.

Do not kick the brushdeck down with your feet. Be gentile.

Switch off the machine when not in use and when you store it.

Do not work without the

r.

Close the cap of the recoverytank, otherwise there’s no water pick-up.

PH between 4 - 9. Temperature max 45oC / 113 oF.

Do not tilt more than 45o. This can cause permanent damage.

Solution tank

Recovery tank

Battery packs

Brushes

Squeegee

Control panel

Vacuum r

tor

Solution + Scrub

Scrub

Scrub + Dry

Scrub + Solution + Dry

Battery Indicator

Water Save mode

Operation

Troubleshooting

Fill the solution tank.PH between 4 and 9.

Temperature max 45oC / 113 oF.

Select youroperating mode

Lower the scrub-deck by hand

Install the battery packs

Install thesolution tank

Install the recovery tank

Maintenance and Care daily weekly monthly

The i-mop won’t startRemove the battery packs from the machine. Inspect the connectors on the battery and on the machine for any damage or obstruction. Reinsert the batteries and switch on the machine. Make sure that the batteries are charged, check them on the charger, recharge when needed or grab a freshly charged set. If the problem still exists we recommend to reset the i-mop according to our reset procedure.

Poor water recoveryPlease ensure that you have chosen the right cleaning mode and the vacuum motor is running. Check the recovery tank, when full empty it. Always empty the recovery tank after cleaning or when you’ve used up all the solution in the solution tank. Inspect both the d and the air ter, clean when needed. Make sure that the recovery tank is seated correctly on the machine, and the cap is scruwed back on the top of the tank. Inspect the rubbers on the squeegee for any damage or wear and tear and that there is nothing stuck inside the squeegee blade blocking the air ow.

Make sure the wheels are clean and that they can turn freely. Detach the vacuum hose from the machine and, check both the hose and the opening on the machine.

Insuf t water ow or no w owCheck if the solution tank is and seated correctly on the machine. Make sure that the right operating mode is selected. Remove the brushes and check the water nozzles on the scrub deck for any obstructions. Empty the solution tank and check the ter, make sure that it is clean. If the ter is dirty, please check that it is cleaned monthly or more often, if required by your circumstances.

ResetMake sure that the i-mop is switched off by returning the knob on the control panel to the off position in the middle. Disconnect both battery packs from the machine and hold down the ‘water save’ button for 30 seconds. Let go of the button and install both battery packs again.