i . i - bracknell forest · 2019-12-12 · 5. concrete to be grade gen 3. 6. unformed surfaces to...
TRANSCRIPT
50 x 50 x 5 mild steel angle iron. 15 dia. holes drilled at 450 centres in the vertical side for 12 dia. stainless steel ragbolts
56 x 10 mild steel flat with 15 dia. Weld holes drilled at 450 centres for 12
dia. stainless steel ragbolts
DETAIL A Prefabricated Protective Grill
ron t
Brick on edge
Protective grille bolted to and apron with
stainless steel ragbolts fabricated from
mild steel flats to angle iron and 150 centres
Detail A)
LO C\I C\I
LO C\I v
coping
headwall 12 dia.
40x10 welded flat at (See
0 0 I")
! . .-. • •. ; .•
225 D + 150 D + 150
2D + 450
SECTION A-A
0
~ + Cl
::c
0
GEN 3 Concrete and toe to be as one.
apcas
D + 450 I . 225 • I . D + 150 • I . . I . D + 150 • I . 225 • I
ELEVATION (Grille omitted for clarity)
Drawing Number
SD/500/10C Notes
1. All dimensions are in millimetres unless shown otherwise.
2. Piping of ditches must have the consent of the EA and the landowner.
3. Brickwork constructed in bricks to BS EN 771 HD Class B in English Bond flush pointed with mortar to designation (i) SHW Series 2400.
4. Brickwork to be:
225 Thick for H < 1.2m 337 Thick for H > 1.2m
5. Concrete to be grade GEN 3.
6. Unformed surfaces to be U2 plain finish.
7. Protective grills must be fitted to all pipes over 300 dia.
8. Grill assembly to have hot dip galvanised finish to BS EN ISO 1461 : 1999 after fabrication.
9. Purpose made units may be used with the approval of the Engineer.
10. Where headwall is adjacent to a footway or cycletrack, a pedestrian guard rail or timber fence is to be provided as determined by the Engineer.
Do not scale this drawing
C APR 19 Updated title block NR B Jun 13 Minor amendments KPT
A Mar 11 Amendments to BS/EN standards. KPT Fencing note added.
Rev Date Checked
Drawing No.
SD/500/10C Scale N.T.S Date t.tAY 04
Department of Place, Planning & Regeneration
0 LO
+ Cl
0 LO
+ Cl
0 LO
D + 150
0
450
0 0 0
150 PLAN
12 dia. stainless steel ragbolts
Project
Title
STANDARD DRAWINGS ~>) .--,1~, Bracknell Forest Council
HEADWALL TYPE 1 UPSTREAM FROM PIPE PIPES 225S?J AND OVER
BRICKWORK CONSTRUCTION