i . i - bracknell forest · 2019-12-12 · 5. concrete to be grade gen 3. 6. unformed surfaces to...

1
50 x 50 x 5 mild steel angle iron. 15 dia. holes drilled at 450 centres in the vertical side for 12 dia. stainless steel ragbolts 56 x 10 mild steel flat with 15 dia. Weld holes drilled at 450 centres for 12 dia. stainless steel ragbolts DETAIL A Prefabricated Protective Grill ron t Brick on edge Protective grille bolted to and apron with stainless steel ragbolts fabricated from mild steel flats to angle iron and 150 centres Detail A) LO C\I C\I LO C\I v coping headwall 12 dia. 40x10 welded flat at (See 0 0 I") ! . .-. •. ; .• 225 D + 150 D + 150 2D + 450 SECTION A-A 0 + Cl ::c 0 GEN 3 Concrete and toe to be as one. ap cas D + 450 I . 225 • I . D + 150 I . . I . D + 150 I . 225 • I ELEVATION (Grille omitted for clarity) Drawing Number SD/500/10C Notes 1. All dimensions are in millimetres unless shown otherwise. 2. Piping of ditches must have the consent of the EA and the landowner. 3. Brickwork constructed in bricks to BS EN 771 HD Class B in English Bond flush pointed with mortar to designation (i) SHW Series 2400. 4. Brickwork to be: 225 Thick for H < 1.2m 337 Thick for H > 1.2m 5. Concrete to be grade GEN 3. 6. Unformed surfaces to be U2 plain finish. 7. Protective grills must be fitted to all pipes over 300 dia. 8. Grill assembly to have hot dip galvanised finish to BS EN ISO 1461 : 1999 after fabrication. 9. Purpose made units may be used with the approval of the Engineer. 10. Where headwall is adjacent to a footway or cycletrack, a pedestrian guard rail or timber fence is to be provided as determined by the Engineer. Do not scale this drawing C APR 19 Updated title block NR B Jun 13 Minor amendments KPT A Mar 11 Amendments to BS/EN standards. KPT Fencing note added. Rev Date Checked Drawing No. SD/500/10C Scale N.T.S Date t.tAY 04 Department of Place, Planning & Regeneration 0 LO + Cl 0 LO + Cl 0 LO D + 150 0 450 0 0 0 150 PLAN 12 dia. stainless steel ragbolts Project Title STANDARD DRAWINGS ~>) .--,1~, Bracknell Forest Council HEADWALL TYPE 1 UPSTREAM FROM PIPE PIPES 225S?J AND OVER BRICKWORK CONSTRUCTION

Upload: others

Post on 11-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: I . I - Bracknell Forest · 2019-12-12 · 5. Concrete to be grade GEN 3. 6. Unformed surfaces to be U2 plain finish. 7. Protective grills must be fitted to all pipes over 300 dia

50 x 50 x 5 mild steel angle iron. 15 dia. holes drilled at 450 centres in the vertical side for 12 dia. stainless steel ragbolts

56 x 10 mild steel flat with 15 dia. Weld holes drilled at 450 centres for 12

dia. stainless steel ragbolts

DETAIL A Prefabricated Protective Grill

ron t

Brick on edge

Protective grille bolted to and apron with

stainless steel ragbolts fabricated from

mild steel flats to angle iron and 150 centres

Detail A)

LO C\I C\I

LO C\I v

coping

headwall 12 dia.

40x10 welded flat at (See

0 0 I")

! . .-. • •. ; .•

225 D + 150 D + 150

2D + 450

SECTION A-A

0

~ + Cl

::c

0

GEN 3 Concrete and toe to be as one.

apcas

D + 450 I . 225 • I . D + 150 • I . . I . D + 150 • I . 225 • I

ELEVATION (Grille omitted for clarity)

Drawing Number

SD/500/10C Notes

1. All dimensions are in millimetres unless shown otherwise.

2. Piping of ditches must have the consent of the EA and the landowner.

3. Brickwork constructed in bricks to BS EN 771 HD Class B in English Bond flush pointed with mortar to designation (i) SHW Series 2400.

4. Brickwork to be:

225 Thick for H < 1.2m 337 Thick for H > 1.2m

5. Concrete to be grade GEN 3.

6. Unformed surfaces to be U2 plain finish.

7. Protective grills must be fitted to all pipes over 300 dia.

8. Grill assembly to have hot dip galvanised finish to BS EN ISO 1461 : 1999 after fabrication.

9. Purpose made units may be used with the approval of the Engineer.

10. Where headwall is adjacent to a footway or cycletrack, a pedestrian guard rail or timber fence is to be provided as determined by the Engineer.

Do not scale this drawing

C APR 19 Updated title block NR B Jun 13 Minor amendments KPT

A Mar 11 Amendments to BS/EN standards. KPT Fencing note added.

Rev Date Checked

Drawing No.

SD/500/10C Scale N.T.S Date t.tAY 04

Department of Place, Planning & Regeneration

0 LO

+ Cl

0 LO

+ Cl

0 LO

D + 150

0

450

0 0 0

150 PLAN

12 dia. stainless steel ragbolts

Project

Title

STANDARD DRAWINGS ~>) .--,1~, Bracknell Forest Council

HEADWALL TYPE 1 UPSTREAM FROM PIPE PIPES 225S?J AND OVER