HYUNDAI1. Production Capacity
5) Manpower for Transformer factory
- 55 Engineers
- 340 Skilled Workers
1) Annual Production Capacity : 28,000MVA
2) Maximum Capacity : up to 800MVA(3 phase)
3) Maximum Voltage : up to 765kV, 2050 BIL
4) Factory Space : 16,800m²
3
HYUNDAI2. Production Range
1) Power Transformer
2) Distribution Transformer
3) Cast resin Transformer
4) Special Purpose Transformer
Rectifier Transformer
Furnace Transformer
Dry type Transformer
Shunt Reactor
Mobile Transformer
4
HYUNDAI3. Quality Assurance (ISO 9001)
1) Original Date of Issue : July of 1989
2) Registered Parts of Quality Assurance
Transformer Design and Development
Production and Testing
Installation and Service
5
HYUNDAI4. Applicable Standard
1) IEC 76 (For Europe and Asia)
2) ANSI C57.12.00 (For America)
3) CAN/CSA-C88-M90 (For Canada)
4) AS 2374 (For Australia)
5) ES 140 (For Korea)
6
HYUNDAI
Specification of Transformer
5. Short Circuit Test
1) Major Performance Record of Short Circuit Test
No. Test DateTest of
Tap Change Customer
1
2
3
4
5
Generating Transformer3PH 6/64/85/106/119MVA 230/14.8kV YNd1
Power Transformer3PH 45/60MVA 154/23kV Ynyno(d)
Power Transformer3PH 35/44MVA 154/23kV YNd1
Distribution Transformer3PH 10MVA 22/6.6kV Ynynod(d)
Power Transformer3PH 20/26MVA 132/11.5kV Dyn11
Sept. 1995
Nov. 1989
Nov. 1986
Dec. 1986
Dec. 1986
N.L.T.C
O.L.T.C
O.L.T.C
O.L.T.C
O.L.T.C
PUD in USA
KEPCO in Korea
In-Chon Iron & Steel in Korea
PUB in Singapore
WAPDA in Parkistan
7
HYUNDAI5. Short Circuit Test
2) Detailed Explanation for the Short Circuit Test Performed to the 230kV Transformers for Rocky Reach Project
Customer : Public Utility District No.1 of Chelan County in U.S.A
Project : Replacement for Rocky Reach Dam Transformer
Transformer Rating
3phase 60Hz 119MVA 14.8/230kV Step-up Transformer
Basic Impulse Level on H.V Side : 900kV
Standard : ANSI C57.12.00
Tested and Certified by Korea Electrotechnology Research Institute
8
HYUNDAI Picture of Short Circuit Test
9
HYUNDAI
1) 765kV Transformer
1PH 60Hz 2 x 333.3MVA 765/345kV
OLTC type Auto transformer (Bil : 2050kV) : 1998
Developed
1PH 60Hz 204MVA 20.9/765kV
NLTC type Step-up transformer (Bil : 2050kV) : 1999
Developed
1PH 60Hz 370MVA 765/345/23kV
NLTC type Auto transformer (Bil : 2050kV) : 1999
Developed
6. Development of Transformer
2) Gas Insulated Transformer
1PH 60Hz 20MVA 154/23kV OLTC Type Transformer
(Under Development)
10
HYUNDAI
3PH 60Hz 40MVA 154/23kV (1996) "H" Class insulation (95C temp. rise) Comparison of "A" and "H" class insulation
Transportation with trailerWeight : 39.4 TonSize(m) : L8.6 x W2.9 x H3.9
3) Mobile Transformer (Developed)
InsulationInsulation No Load LossNo Load Loss Load LossLoad Loss WeightWeight
“A” Class
“H” class
Remark
31 kW
23 kW
74%
241 kW
434kW
180%
35 TON
25 TON
71%
6. Development of Transformer
11
HYUNDAI
Picture of 154kV 40MVA Mobile Transformer-Using H Class Insulation (NOMAX Paper)
12
HYUNDAI7. Major International Clients and Performances
1) North America
CountryCountry ClientClient Rating of TransformerRating of Transformer
U.S.A
Alumnium Company of America
Los Angeles Department of Water and Power
Chelan Country
Black & Veatch
General Electric Company
Baltimore Gas & Electric
CRS Sirrine Engineers
Zurn Nepco
Westinghouse
Florida Power Corporation
Colorado River Commission of Nevada
Sacramento Municipal Utility District
Duke Fluor Daniel
Babcock & Wilcox Engineering
Lower Colorado River Authority
Puget Sound Energy
National Electrical System Inc.
City of Tacoma
New York Power Authority
161/13.8kV, 93MVA
34.5/5.04kV, 16MVA
230/14.8kV, 119MVA
230/15.75kV, 315MVA
138/13.8kV, 125MVA
13.8/2 X 3.9kV, 20MVA
69/13.8KkV, 90MVA
132/11.5kV, 90MVA
138/13.8kV, 150MVA
16/230kV, 235MVA
230/69kV, 200MVA
230/69/13.8kV, 200MVA
115/11kV, 93MVA
138/15.5kV, 160MVA
138/22.8kV, 490MVA
230/117.8kV, 325MVA
115/13.2kV, 115MVA
115/13.8kV, 56MVA
230/13.2kV, 86MVA
13
HYUNDAI7. Major International Clients and Performances
2) South America
CountryCountry ClientClient Rating of TransformerRating of Transformer
Colombia
Interconexion Electrical S.A
EPM
ESSA
Trinidad & Tobogo Electricity Commission (TTEC)
CELMEC
Chilectra
230/34.5kV, 50MVA
500/230/34.5kV, 150MVA
230/115/46kV, 90MVA
115/34.5/13.8kV, 40MVA
33/12kV, 6MVA
115/13.8kV, 50MVA
230/110/13.2kV, 130MVA
Trinidad & Tobago
Panama
Chile
Proyecto Ampliacion de LA S. E. 220/60/10kV, 50MVAPeru
JBV Guatemala, LCC 230/13.8kV, 150MVAGuatemala
ENELVEN 200/115/13.8kV, 200MVAVenezuela
Abengoa 115/2 X 13.8kV, 300MVAPuerto RicoCERJ 138/13.8kV, 33.3MVABrazil
14
HYUNDAI7. Major International Clients and Performances
3) Asia
CountryCountry ClientClient Rating of TransformerRating of Transformer
Tokyo Electric Power Company
Public Utilities Board (PUB)
66/6.9kV, 20MVA
22/6.6kV, 10MVA
Japan
Singapore
Tenaga Nasional Bhd. (TNB) 275/132kV, 240MVAMalaysia
Sarawak Electricity Supply Corp. (SESCO) 275/230kV, 250MVA
Sabah Electricity Board (SEB) 275/132kV, 180MVA
Perusahaan Umum Listrik Negara (PLN) 150/20kV, 100MVAIndonesia
National Power Corp (NPC) 230/115/13.8kV, 300MVAPhilippines
Manila Electric Company (MERALCO) 110/34.5/13.8kV, 83.3MVA
Electricity of Vietnam (EVN) 230/121/22kV, 63MVAVietnam
Vietnam POSCO Steel Co. 110/6.6kV, 20MVA
Bangladesh Power Development Board (BPDB) 240/140kV, 150MVABangladesh
15
HYUNDAI7. Major International Clients and Performances
CountryCountry ClientClient Rating of TransformerRating of Transformer
Electricity Generating Authority of Thailand (EGAT)
Metropolitan Electricity Authority (MEA)
115/34.5/11kV, 50MVA
60/11.5kV, 60MVAThailand
Provincial Electricity Authority (PEA) 115/23.1kV, 40MVA
Myanmar Myanmar Electric Power Enterprise (MEPE) 132/33/11kV, 30MVA
Water and Power Development Authority (WAPDA) 230/11kV, 125MVA
Karachi Electricity Supply Corporation (KESC) 132/11kV, 40MVAParkistan
D. G Khan Cement Company 132/6.3kV, 20/26MVA
India Oil and Natural Gas Commission (ONGC) 6.6/0.433kV
2000KVA (Cast Resin Type)
Ceylon Electricity Board (CEB) 132/33kV, 31.5MVASrilanka
3) Asia
16
HYUNDAI7. Major International Clients and Performances
4) Middle East
CountryCountry ClientClient Rating of TransformerRating of Transformer
Electricity Corporation
SCECO-Central
132/33kV, 60MVA
132/13.8kV, 100MVASaudi Arabia
SCECO-East 230/115/34.5kV, 400MVA
Iraq
Tabouk Electricity Company 132/13.8kV, 100MVA
Arabian American Oil Company 66/13.8kV, 67MVA
State Organization of Electricity (SOE) 400/138.6/11kV, 250MVA
Yemen Yemen General Electricity Corp. (YGEC) 132/33kV, 25MVA
Water and Electricity Department 11/0.433kV, 1500KVA(Cast Resin Type)
U.A.E
Lebanon Council for Development & Reconstruction 66/20-11kV, 40MVA
Dubai Electricity Company 33/11kV, 15MVA
Oman Ministry of Electricity and Water 33/11kV, 20MVA
Turkey Turkiye Electric KurumuShunt Reactor154kV, 5MVAR
17
HYUNDAI7. Major International Clients and Performances
5) Oceania and Canada
CountryCountry ClientClient Rating of TransformerRating of Transformer
Pacific Power (The Electricity Commission of New Sourth Wales)
132/11kV, 20MVA
132/69/11kV, 20MVA
Australia
Power Link (Queensland Electricity Commission) 230/34.5kV, 80/120MVA
New Zealand
BHP Engineering Pty Ltd. 132/66/11kV, 120MVA
Shortland County Council 66/13.8kV, 67MVA
New Zealand Aluminium Smelter Ltd. (NZAS) 220/11kV, 50MVAPapua New Guniea
The Electricity Commission of P.N.G 132/66kV, 20MVA
Canada
British Columbia Hydro & Power AuthorityRichmond Hill Hydro
Manitoba Hydro
Alberta Power Ltd.
Howe Sound Pulp & Paper Ltd.
Yukon Electrical Company
Stone & Webster Canada Ltd.
Transalta Vtilities
Agra Monenco/ Aurora Mine
Saskatchewan Power Corporation
512.5/242/25.2kV, 500MVA
212.5/2 X 28kV, 125MVA
138/13.8kV, 40MVA
243/2 X 13.8kV, 171MVA
260/72kV, 224MVA
260/72kV, 116.2MVA
114.3/2 X 12.47kV, 50MVA
144/25kV, 50MVA
230/13.8kV, 62MVA
128/24.9kV, 29.8MVA
18
HYUNDAI7. Major International Clients and Performances
6) Europe
CountryCountry ClientClient Rating of TransformerRating of Transformer
ABB Power Generation Ltd. 220/21kV, 420MVASwitzerland
Germany
Denmark
Siemens AG
Johs Gran-Hassen Product Ltd.
132/6.9kV, 40/45MVA
220/60/10kV, 40/50MVA
7) Africa
CountryCountry ClientClient Rating of TransformerRating of Transformer
Egyptian Electricity Authority (EEA) 21/220kV, 395MVAEgypt
Ethiopia
Arco Steel
Ethiopian Electric Light and Power Authority (ELPA)
220/22.5kV, 80MVA
132/15kV, 22MVA
Libya Heavy Industries Secretariat Tripoil SocialistPeople’s Libyan Arab Jamshebreya
11/225kV, 105MVA
19
HYUNDAI8. Major Production Facilities
1) Over-Head Crane (300 TON x Span 38m)
2) Vacuum Vaporization Facility (L 13m x W 4.8m x H 6.6m)
3) Air - Cleaning Facility (L 45m x W 40m x H 7m)
4) Oil Filtering Machine (8,00 litter / hour)
5) Motorized Transporter for Test (400 TON x 2EA)
6) Core Binding Machine (40 TON x W 8m)
7) Core Lamination Table (120TON)
20
HYUNDAI9. Major Testing Facilities
1) Impulse Generator System ( 400KV / 600KJ )
2) Oscillation Lightning Impulse Test System (1,800KV / 90KJ )
3) AC Series Resonant Voltage Test System
(1,200KV / 4,800KVA )
4) AC Power Generator System ( 23MVA x 2sets )
5) AC Power Generator System ( 23MVA x 2sets )
6) Condenser Bank ( 158KV, 225MVAR )
7) Transformer Loss Measuring System (200KV / 4,000A )
21
HYUNDAI10. Major Manufacturing Process
1) Winding Works
22
HYUNDAI10. Major Manufacturing Process
2) Core lamination
23
HYUNDAI10. Major Manufacturing Process
3) View of Core Structure (After Completion of Core Lamination)
24
HYUNDAI10. Major Manufacturing Process
4) Coil Insertion Works
25
HYUNDAI10. Major Manufacturing Process
5) View of Core and Coil Assembly Works
26
HYUNDAI10. Major Manufacturing Process
6) Drying Works in Vacuum Vaporization Facility
27
HYUNDAI10. Major Manufacturing Process
7) Completion of Core & Coil Assembly
28
HYUNDAI10. Major Manufacturing Process
8) Factory Test