hydrosense: infrastructure-mediated single-point sensing of whole-home water activity ubicomp 2009...

23
HydroSense: Infrastructure-Mediated Single-Point Sensing of Whole-Home Water Activity UbiComp 2009 Jon Froehlieh, Eric Larson, Tim Campbell, Conor Haggerty, James Fogarty, Shwetak N. Patel CS542 Internet system technology Presenter : Kim Young-sun

Upload: sophie-melton

Post on 01-Jan-2016

221 views

Category:

Documents


0 download

TRANSCRIPT

HydroSense: Infrastructure-Mediated Single-Point Sensing of Whole-Home Water Activity

UbiComp 2009

Jon Froehlieh, Eric Larson, Tim Campbell, Conor Haggerty, James Fogarty, Shwetak N. Patel

CS542 Internet system technologyPresenter : Kim Young-sun

Introduction

• Important things in ubiquitous computing research and practice are…Effective methods for

Sensing and Modeling human activity

• And requirements are…Practical / Low-cost / Unobtrusive

Sensing human activity

• Three approaches of sensing human activity- Mobile and wearable sensing- Environmental sensing- Infrastructure-mediated sensing

Sensing human activity

• Three approaches of sensing human activity- Mobile and wearable sensing- Environmental sensing- Infrastructure-mediated sensing

Sensing human activity

• Three approaches of sensing human activity- Mobile and wearable sensing- Environmental sensing- Infrastructure-mediated sensing

Sensing human activity

• Three approaches of sensing human activity- Mobile and wearable sensing- Environmental sensing- Infrastructure-mediated sensing

water, electrical, and HVAC infrastructures

Infrastructure-mediated Sensing• Especially, sensing of water activity

E.g. Sensing from the Basement: A Feasibility Study of Unobtrusive and Low-Cost Home Activity Recognition

HydroSense

• A low-cost, single-point solution foractivity sensing mediated by a home’s existing water infrastructure

• Advantages…- Easily installed- analysis of pressure

- identify individual water fixtures

- estimate the amount of water being used

- diverse evaluation

Background

• In-home plumbing system

Background

• Pressure wave by valve open/close events

Water Hammer

Background

• Estimating Flow

Poiseuille’s law

Fluid resistanceformulation

resulting in :

Pressure Drop

Radius of the pipe

Length of the pipe

Viscosity of the fluid

Prototype Sensor Design

• Prototype sensor implementation

In-home data collection

• Collected labeled data in– ten homes in four cities

of varying, style, age, and diversity of plumbing system

• Measurement process– Measured the baseline static water pressure– Installed the appropriated HydroSense unit– Collect data

* 706 fixture trials and 155 flow rate trials across 84 fixtures

In-home data collection

• A summary of the homes

Fixture event identification

• Three-step approach

(1) Segment each individual valve event

(2) Classify each valve event as either a valve open or valve close

(3) Classify the valve event according to the individual fixture that generated it

Valve Event Segmentation

• Smooth raw signal using a low-pass linear phase finite impulse response filter• Analyze in a sliding windows of 1000 samples (one second of sensed pressure)• Check conditions of beginning and end of a valve event

Classifying Valve Events

• After segmenting each valve event,classify it as either a valve open or a valve close event

• Hierarchical classifier

Fixture Classification

• Associate valve open and valve close events with individual fixtures using a template-based hierarchical classifier

• Four complementary distance metrics– Matched filter– Matched derivative filter– Real Cepstrum– Mean squared error

Fixture Classification

• Similarity thresholds are learned from training data

• If no template passes all four filters,– The unknown event is not classified

• If templates corresponding to multiple fixtures pass all filters, – Choose among them using a nearest-neighbor classifier

defined by the best performing distance metric, the matched derivative filter

Fixture Classification Evaluation• Cross-validation experiment in different view

Analysis of flow estimation

• Individually Calibrated Valves

Analysis of flow estimation

• Generalizing to Uncalibrated Valves

Discussion

• Limitation and future work