hydrolink general product catalogue

17
JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 Fax: +971-4-8861413 e-mail: [email protected] APPLICATIONS Compressed Air Dryer packages skid mounted by Hydrolink, are complete air treatment systems that include an air driven Pre-cooler with Moisture Separator, Coalescing Pre Filter, Heatless Desiccant Air Dryer and a particulate removal After Filter. The versatile skid packages are built to the highest standards and are designed to stringent offshore specifications. Pipeline cleaning, drying and testing Process / Power plants Commissioning instruments Instrument Air / Plant Air during outages Drilling Catalyst regeneration Shot blasting & Painting Temporary extra capacity SPECIFICATION Type Rated Flow - m³/hr ( scfm ) Maximum Air Inlet Pressure - bar (psi) Minimum Air Inlet Pressure - bar (psi) Dew point Options Inlet/Outlet - mm (in) Controls Pre cooler HL-ADS-800-10 Heatless/Desiccant 1920 (1130) 10.3 (149.35) 4.1 (59.45) -40 ˚C /-70 ˚C 76 (3) Pneumatic Air cooled/Air motor driven HL-ADS-1600-10 Heatless/Desiccant 3568 (2100) 10.3 (149.35) 4.1 (59.45) -40 ˚C /-70 ˚C 102 (4) Pneumatic Air cooled/Air motor driven HL-ADS-3000-10 Heatless/Desiccant 5097 (3000) 10.3 (149.35) 4.1 (59.45) -40 ˚C /-70 ˚C 152 (6) Pneumatic Air cooled/Air motor driven www.hydrolinkgroup.com HL-F-0909/001.01

Upload: marcoalba

Post on 12-Mar-2015

450 views

Category:

Documents


15 download

TRANSCRIPT

Page 1: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

APPLICATIONS

Compressed Air Dryer packages skid mounted by Hydrolink, are complete air treatment systems that include an air driven Pre-cooler with Moisture Separator, Coalescing Pre Filter, Heatless Desiccant Air Dryer and a particulate removal After Filter. The versatile skid packages are built to the highest standards and are designed to stringent offshore specifications.

Pipeline cleaning, drying and testingProcess / Power plants Commissioning instrumentsInstrument Air / Plant Air during outagesDrillingCatalyst regenerationShot blasting & PaintingTemporary extra capacity

SPECIFICATION

Type

Rated Flow - m³/hr (scfm )

Maximum Air Inlet Pressure - bar (psi)

Minimum Air Inlet Pressure - bar (psi)

Dew point Options

Inlet/Outlet - mm (in)

Controls

Pre cooler

HL-ADS-800-10

Heatless/Desiccant

1920 (1130)

10.3 (149.35)

4.1 (59.45)

-40 ˚C /-70 ˚C

76 (3)

Pneumatic

Air cooled/Air motor driven

HL-ADS-1600-10

Heatless/Desiccant

3568 (2100)

10.3 (149.35)

4.1 (59.45)

-40 ˚C /-70 ˚C

102 (4)

Pneumatic

Air cooled/Air motor driven

HL-ADS-3000-10

Heatless/Desiccant

5097 (3000)

10.3 (149.35)

4.1 (59.45)

-40 ˚C /-70 ˚C

152 (6)

Pneumatic

Air cooled/Air motor driven

www.hydrolinkgroup.com

HL-

F-09

09/0

01.0

1

Page 2: Hydrolink General Product Catalogue

www.hydrolinkgroup.com

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

Hydrolink offer a large selection of pump units for de-watering, filling, pressure testing and pipeline flushing. Drives can be diesel or electric and the pump units are skid mounted with on-board fuel tanks for diesel units.

Special purpose pump sets, for the Oil & Gas, Petrochemical and Offshore sectors, can be built to order.

De-wateringVolume fillingPipeline flushingPressure testingChemical flushing

APPLICATIONS

Can be bui l t to customer speci f icat ion on request*Duty Point

SPECIFICATION

Impel ler - mm ( in)

Casing

*Pressure - bar (psi)

Flow - m³/hr (US gpm)

Power - kW (hp)

Length - mm ( in)

Width - mm ( in)

Height - mm ( in)

Weight - Kg ( lbs)

DP-KRZ-200

390 (15)

End Suction

6 (87)

500 (2201)

110 (1721)

2700 (106)

1500 (59)

2100 (83)

2000 (4400)

DP-100H

470 (18)

2-Stage

20 (290)

150 (660)

150 (200)

3500 (138)

1800 (71)

2250 (89)

3500 (7700)

DP-150D

515 (20.3)

Split Case

12 (174)

600 (2641)

250 (333)

4000 (157)

1800 (71)

2250 (89)

4500 (9900)

DP-250DF

525 (20.7)

Split Case

13 (189)

1200 (5282)

580 (771)

5000 (197)

1800 (71)

2750 (108)

7000 (15400)

DP-250D

542 (21.5)

Split Case

13 (189)

1500 (6603)

580 (771)

5750 (226)

1800 (71)

2500 (98)

7500 (16500)

DP-150H

595 (23.4)

2-Stage

30.5 (442)

600 (2641)

580 (771)

5750 (226)

1800 (71)

2500 (98)

7500 (16500)

DP-300D

590 (23.2)

Split Case

12 (174)

2400 (10564)

1260 (1676)

6000 (236)

1800 (71)

2500 (98)

8000 (17600)

HL-

F-09

09/0

02.0

1

Page 3: Hydrolink General Product Catalogue

HYDROLINKCOILED TUBING ‘DROP IN DRUM’SPOOLER SYSTEM

STANDARD SPECIFICATION

65 Ton Dynamic Load for Oilfield and OffshoreApplications

Weight and Dimensions

Unladen weight (without drum) : 13,500kg (29,700lbs)Length of skid (closed) : 5.2m (205”)Length of skid (extended) : 7.1m (280”)Width of skid : 3.0m (118”)Height of skid (without drum) : 3.7m (146”)Height of skid (with drum) : 6.3m (248”)

Shaft

Internal bore : 48mm (1.88”)Continuous working pressure : 690bar (10,000psi)

Other features

• Up to 50,000Nm (36,000lb-ft) torque at 350 bar(5,000psi).• Capacity (incl. mud/water) : 65,000kg (143,000lbs).• Shaft with WECO threaded fittings for swivel and slip ring.• Level wind arm inclination up to 50° (horizontal).• Electronic control of hydraulic spool mechanism.• Local and remote control stations – both with manual and electronic control.• High utilization capability for continuous use.

The Hydrolink Coiled Tubing Spooler unit HL-CTS-65 is a telescopic coiled tubing spooler that can be hydraulically adjusted to a wide range of drum diameters and widths.

It features the industry’s most robust Hagglunds direct drive motors, offering superior reliability over chain sprocket systems.

The unit utilises standard shipping drums – wood and steel.

Where necessary, spoolers can be tailored to specific customer requirements.

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

www.hydrolinkgroup.com

HL-

F-09

09/0

03.0

1

Page 4: Hydrolink General Product Catalogue

www.hydrolinkgroup.com

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

36 Cartridges 1016 mm (40”) long

150 m³/hr (660 US gpm) per Vessel

10 bar (145 psi)

-29 °C to 107 °C ( -20 °F to 225 °F )

ASME Code Design and ‘U’ Stamp

6” ANSI, Class 150

2” NPT Ball Valve

1” NPT Ball Valve

½” NPT Ball Valve

SS 316 Wetted Parts

Mild Steel

Cast Iron body, SS-316L Disc, SS Piping

Load certified eyes; Forklift pockets

2225 kg (4895 lbs)

2900 x 1250 x 2250 (114” x 49” x 89”)

HL-DFS-NU-210M-10B-M-SS-316L HL-DFS-NU-275M-10B-M-SS-316L

55 Cartridges 1016 mm (40”) long

225 m³/hr (990 US gpm) per Vessel

10 bar (145 psi

-29 °C to 107 °C (-20 °F to 225 °F)

ASME Code Design and ‘U’ Stamp

6” ANSI, Class 150

2” NPT Ball Valve

1” NPT Ball Valve

½” NPT Ball Valve

SS 316 Wetted Parts

Mild Steel

Cast Iron body, SS-316L Disc, SS Piping

Load certified eyes; Forklift pockets

2300 kg (5060 lbs)

2900 x 1250 x 2250 (114” x 49” x 89”)

No. of Cartridge per Filter Housing

Max. Recommended flow

Design Pressure

Design Temperature

Design of Vessel

Inlet / Outlet

Dirty Drain

Clean Drain

Vent

Material of Filter Housing / Vessel

Material of Frame & Skid

Material of Pipes and Valves

Lifting

Skid Weight

Dimension - mm (in)

Hydrolink design and manufacture high flow, multi-purpose filter skids, used extensively in oilfield, power generation and utility industries.The versatile skid packages are built to the highest standards and can be configured for both parallel and series flow.

Diesel filtrationCompletion fluidsWater injectionProduced water polishingPrefiltration to RO systems

APPLICATIONS

SPECIFICATION

HL-

F-09

09/0

04.0

1

Page 5: Hydrolink General Product Catalogue

HL-

F-09

09/0

06.0

1

Hydrolink HFPS fluid purifier units are easy to operate, self contained systems that will:

Remove free, dissolved and emulsified water. Remove free and dissolved gases. Remove particulate contamination over 3micron. Reduce equipment / system downtimes. Reduce component failures. Reduce fluid changes. Increase equipment reliability and productivity.

Effects of Water Contamination

Water is one of the most common fluid contaminants, and the most destructive after particulate contamination, causing:

Fluid breakdown. Additive depletion. Reduction of lubrication properties. Oil oxidation. Internal corrosion. Abrasive wear in system components. Reduced dielectric strength.

Principle

Hydrolink Fluid Purifier Units employ a modified version of the vacuum evaporation with inert gas dehydration technique, using dry air in place of the inert gas. A desiccant air dryer is used to dry the inert gas and increase purifier efficiency, even in high humidity environments. In contrast to the standard vacuum evaporation process, this technique can achieve residual water levels below the saturation level of the fluid being processed.

Operation

Contaminated fluid is drawn into the unit under a vacuum of up to 0.9 bars, passing through a heater to raise its temperature and increase filtration speed. It then enters a vacuum tower where it cascades over dispersal elements to break it down into droplets, thus increasing the surface area.

The water is vaporized and drawn off through the vacuum pump and a condenser to the drainage reservoir.

The treated fluid is pumped from the tower by a hydraulic pump and passed through a high efficiency particulate removal filter before being returned to the system. An installed water sensor allows permanent control of the saturation of the fluid.

Technology

The HFPS systems are fully automated, PLC- controlled units. The WSPS 03 water sensor, in conjunction with the WFD 01 display unit, allows permanent monitoring of the water level in the purified fluid, and the VS1 Delta P sensor allows optimal scheduling of filter replacement.

SPECIFICATION

Water extraction rate - l/day (US gpd)*

Flow rate - lpm (US gpm)

75 (19.8)

20 (5.3)

105 (27.7)

30 (7.9)

315 (83.2)

70 (18.5)

450 (118.8)

100 (26.4)

HFPM.31 HFPM.71 HFPM.101HFPM.21

• Also available in explosion-proof versions. Based upon 6% water @ 40 OC for VG 32 mineral oil.

• Fluid Purifier Skid packages can be built to suit specific system requirements.

APPLICATIONS

Oil Conditioning and PolishingTurbine oil PurificationTransformer oil Purification

Page 6: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

APPLICATIONS

SPECIFICATION

www.hydrolinkgroup.com

Electric and diesel driven flushing units reduce contamination and provide a defined system cleanliness level. Hydrolink flushing units have been proven to reduce system downtime and maintenance costs.

Hydraulic pipeline cleaningNew piping installationHydraulic flushing and system performance

Electric Motor Capacity - kW (hp)

Diesel Engine Capacity - kW (hp)

Working Pressure - bar (psi)

Flow - lpm (US gpm)

Hydraulic Tank Capacity-L (US gal)

Weight (w/oil) - kg (lbs)

37 (50)

N/A

200 (2900)

0 to 80 (0 to21)

200 (52)

1200 (2640)

75 (101)

N/A

200 (2900)

10 to 150(2.6 to 39.6)

400 (104)

2000 (4400)

N/A

48 (64)

150-260 (2175-3770)

162-38 (43-10)

400 (104)

3000 (6600)

N/A

109 (146.6)

136-195-240(1972-2827-3480)

408-284-142 (107-75-37)

1800 (468)

4000 (8800)

N/A

109 (146.6)

350-210-210(5075-3045-3045)

90-110-45(23-29-12)

1800 (468)

4000 (8800)

DHU-1800L-D109K-V245L-210B

DHU-400L-D48K-V200L-260B

DHU-1800L-D109K-V840L-240B

EPU-200L-E37K-P80L-200B

EPU-400L-E75K-P150L-200B

EPU-E55K-S1700L-12B-VFD

55 (74)

N/A

12 (160)

220 to 1721(57 to 444)

N/A

1800 (4000)

* Can be built to customer specification

HL-

F-09

09/0

07.0

1

Page 7: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

www.hydrolinkgroup.com

Pressure - bar (psi)

Flow - lpm (US gpm)

Power - kW (hp) * Speed - rpm

150 (2150)

61 (16)

17.8 (24)

1450

HPP-24-KE28

250 (3625)

37 (97)

17.7 (23.7)

1450

HPP-24-KE22

210 (3050)

45 (12)

18.1 (25)

1450

HPP-24-KE24

300 (4350)

30 (8)

17.3 (23)

1450

HPP-24-KE20

130 (1850)

70 (18.8)

17.6 (23.5)

1450

HPP-24-KE30

* Quoted power requirement based upon 87.5% efficiency.

KE SERIES - 130 Bar - 300 Bar

Hydrolink offer a wide range of skid mounted Diesel or Electric driven High Pressure Pumps. Ideal for industrial cleaning and many other purposes. Hydrolink Pump Sets are robust, self contained units for heavy duty applications.

Industrial cleaningTube bundle cleaningDrainage cleaningPressure testingMarine growth removalDock/Hull washing

APPLICATIONS

UP TO 1800 Bar

Page 8: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

www.hydrolinkgroup.com

HL-

F-09

09/0

08.0

1

VF SERIES - 800 Bar - 1500 Bar

800 (11600)

23 (6.1)

35.3 (48)

1000

HPP-24-VF14-23

1500 (21750)

12 (3.2)

36.1 (49)

750

HPP-24-VF12-12

1200 (17400)

15 (4)

34.6 (46)

900

HPP-24-VF12-15

1100 (15950)

17 (4.5)

35.9 (48)

750

HPP-24-VF14-17

Pressure - bar (psi)

Flow - lpm (US gpm)

Power - kW (hp) * Speed - rpm

KAMAT SERIES - HIGHER FLOW

810 (11745)

72 (19)

112 (150)

475

HPP-24-K10026

955 (13847)

61 (16)

112 (150)

475

HPP-24-K10024

1370 (19865)

51 (13)

134 (180)

475

HPP-24-K10022

700 (10150)

83 (22)

112 (150)

475

HPP-24-K10028

Pressure - bar (psi)

Flow - lpm (US gpm)

Power - kW (hp) * Speed - rpm

HF SERIES - 280 Bar - 600 Bar

Pressure - bar (psi)

Flow - lpm (US gpm)

Power - kW (hp) * Speed - rpm

500 (7250)

38 (10)

36.5 (49)

1000

HPP-24-HF18-38

400 (5800)

45 (11.9)

34.6 (46)

800

HPP-24-HF22-45

280 (4060)

74 (19.5)

39.8 (53)

1000

HPP-24-HF25-74

600 (8700)

30 (8)

34.6 (46)

800

HPP-24-HF18-30

* Quoted power requirement based upon 87.5% efficiency.

Page 9: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

MAIN FEATURES

* Can be built as per customer specification

www.hydrolinkgroup.com

The Hydrolink Mobile Hydraulics Workshop is a portable, self-contained, hydraulics assembly and repair facility, designed specifically for the maintenance of hydraulic hoses and cylinders in the field. The fully equipped unit has an integral diesel generator and air conditioning/heat pump system and is designed to be handled as a standard 40’ shipping container for use onshore and offshore.

APPLICATIONSHose assembly and repair Cylinder repair and maintenanceHydraulic testing

HYDROLINK MOBILE HYDRAULICS WORKSHOP

Hose cutting machine

Crimping machine

Skiving machine

Tube bending machines

Bench grinder

Bench drilling machine

Bench drilling machine

Air conditioner/heat pump

HL-WC-40-AC/O

Hydraulic power pack

Cylinder test unit

Work benches

Washing basin

Parts storage

Tool storage

Office area

Diesel generator

HL-

F-09

09/0

09.0

1

Page 10: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

APPLICATIONSPipeline dryingInert gas chargingLeak detection

SPECIFICATIONHL-UEM-180-NFSK HL-SPS-180-NFSK

Maximum gaseous nitrogen flow rate – m³/min (scfh)

Maximum working pressure – bar (psi)

Maximum gaseous nitrogen temperature – ˚C (˚F)

Engine power kW (hp)

Engine

Pump drive arrangement

Boost pump

Main pump

Piping

85 (180,000)

1,030 (15,000)

21 (70)

410 (550) @ 2,100 rpm

Detroit Diesel Series 60

Hydraulic

Centrifugal

Triplex Cryogenic

304L/316L stainless steel

85 (180,000)

1,030 (15,000)

21 (70)

490 (657) @ 2,240 rpm

Caterpillar 3406

Hydraulic

Centrifugal

Triplex Cryogenic

304L/316L stainless steel

* Other specifications available.

www.hydrolinkgroup.com

The Hydrolink skid mounted, self-contained, non-fired Nitrogen Pumping Unit is a diesel-driven high pressure nitrogen pump for use in applications such as pipeline drying, nitrogen charging and leak testing. This high specification product utilizes modern cryogenic technologies and materials, and has many special features to facilitate operation and enhance safety in the field. Incorporating both fork-lift portability and a rugged 4-point lifting frame, these pumps are suitable for both onshore and offshore environments. Units can be supplied in either “zoned” or “non-zoned” specifications.

HL-

F-09

09/0

10.0

1

Page 11: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

APPLICATIONSHigh pressure jettingHydrostatic testing

SPECIFICATION

Drive

Maximum flow – l/min (US gpm)

Maximum pressure – bar (psi)

Power – kW (hp)

Motor rating – kW (hp)

Water tank capacity – lit (US gall)

Length – mm (in)

Width – mm (in)

Height – mm (ins)

Weight – kg (lbs)

Electric

12.7 (3.4)

1500 (21750)

37 (50)

45 (60)

350 (92)

1650 (65)

1010 (40)

2010 (79)

1050 (2320)

* Can be built to customer specification on request.

www.hydrolinkgroup.com

The Hydrolink Offshore Jetting & Testing Unit combines the functions of high pressure water jetting and hydrostatic testing in one compact package. Based on Hydrolink’s well proven electric drive high pressure pump units, it has been designed specifically for offshore use. The unit has separate facilities for jetting and hydrostatic testing, and incorporates a chart recorder to document test results. It features an explosion-proof drive motor and controls and is packaged in a robust crash frame with 4-point lift.

HPP-24-VF12-12-E45-HT-CR-Z1

HL-

F-09

09/0

11.0

1

Page 12: Hydrolink General Product Catalogue

A set of offline filtration units that range from a basic electric trolley to an explosion proof unit with built-in contamination monitoring. The units are lightweight, portable and available in four flow sizes. The Hydrolink filtration trollies are simple to operate, clean and maintain, and significantly reduce equipment maintenance costs.

SPECIFICATION

Pump

Drive

Flow Rating - lpm (US gpm)

Viscosity

Max. Operating Pressure

Max. Operating Temp.

Compatibility

Test Point

Fi l ter Element

Part ic le Monitor (Onl ine)*

35 (9) 250 (62) 20 (5) 71 (18)

10-400 cst

4 bar (60 psi)

55 ˚C (131 ˚F)

Hydraulic oil based mineral oil

Gear Pump

Electric230V (1-ph)

Electric 380V (3-ph)

Electric380V (3-ph)

Pneumatic20lps @ 7bar

Fluid sampling and dignostics if required

Choice of absolute rated filters.

Provide particle information at 4, 6 & 14 microns vv

Filtering particles from new oilImproving cleanliness in fluid systemsSystem flushing

APPLICATIONS

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

www.hydrolinkgroup.com

HYDROLINKPORTABLE FILTER UNITSFiltration trolley integrated with on-line particle counters to measure / monitorthe oil cleanliness levels as perISO 4406 cleanliness standards.

HFCT-020-TP-03-NS-VPC

HFCT-035-AM-03-NS

HFCT-080-TP-03-NS-VPC

HFCT-240-TP-03-NS-VPC

* Optional: Avilable only with electric motor.

HL-

F-09

09/0

12.0

1

Page 13: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

Concrete crushingHydraulic pressesHydraulic drivesPipe fusionHull cleaning

APPLICATIONS

www.hydrolinkgroup.com

SPECIFICATIONEPU-100L-EE5.5K

-G9L-150BEPU-160L-EE2.2K

-G6L-150BEPU-300L-E30K

-SP80L-160BEPU-630L-E75K

-P160L-220BEPU-1000L-2E55K

-2SP133L-210BEPU-1400L-E110K

-TV1000L-415B

Working Pressure - bar (psi)

Flow - Ipm (US gpm)

Hyd. Tank Capacity - L (US gal)

Weight (w/o oil) - kg (lbs)

150 (2178)

9 (2.4)

100 (26)

200 (440)

150 (2175)

6x2 (1.6x2)

160 (42)

250 (550)

160 (2320)

80 (21)

300 (78)

350 (770)

220 (3190)

600 (158)

1800 (3960)

210 (3045)

1000 (264)

2800 (6160)

Electric Motor Capacity kW (hp) 5.5 (7.5) 2.2x2 (3x2) 30 (40) 75 (100) 55x2 (74x2) 110(150)

415 (6018)

1000 (264)

1400 (364)

2100 (4620)

160 (42) 133x2 (35x2)

HL-

F-09

09/0

13.0

1

Hydrolink hydraulic power packs are very low noise, compact units. Designed for a maximum operating pressure of 400 bar at maximum pump volume, standard units include a separate filter/cooler circuit, easy access for maintenance, a proportional control system, safety interlocks on oil level and temperature, and tanks designed to BS 6525:1984.

Where applications dictate, these units can be supplied with stainless steel or aluminum tanks, suitable components for water-glycol systems, a tank heater, air-cooled or water-cooled external coolers, accumulators and in-built umbilicals for hydraulic tools. Options include zone-rated and diesel driven units, and 3rd Party certification can be provided.

Page 14: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

APPLICATIONSCantilever skiddingBOP skidding

Cantilever skidding systems, available in the longitudinal transverse or combination axes.Power units can be produced to Zone 1 specification and control units can either be combined with the power unit or supplied as a stand-alone console.

SPECIFICATION

Axis

Load Capacity - Ton

Speed - m/min (ft/min)

Elec. Motor Capacity - Kw(hp)

No. of Cylinders

Hydraulic Units

Working Pressure - bar (psi)

Flow - lpm (US gpm)

Hyd. Tank Capacity - L(US gal)

Weight - kg (lbs)

HL-SK-L800T/T400T

Longitudinal

800/400

0.5 (1.65)

55 x 2 (74 x 2)

4+2

1

215 (3118)

231 (61)

1000 (264)

4000 (8800)

HL-SK-T-250T

Transverse

250

0.8 (2.5)

55 (74)

2

1

215 (3118)

130 (34)

600 (158)

2500 (5500)

HL-SK-L-900T

Longitudinal

900

0.5 - 1 (1.6 - 3.2)

110 (147)

4

1

170 (2465)

320 (85)

1200 (315)

3000 (6600)

HL-SK-T-200T

Transverse

200

0.7 (2.3)

55 (73)

2

1

210 (3000)

140 (37)

400 (105)

2500 (5500)

Longitudinal

1400/140

0.3 (1.0)

75 x 2 (100 x 2)

4+2

1

210 (3045)

186 (48)

1000 (264)

4400 (9680)

HL-SK-L1400/T140T

HL-SK-L940T/T250T

Longi./Trans.

940/250

0.6 (2)

66 x 2 (88 x 2)

4 + 2

1

207 (3000)

146 x 2 (38 x 2)

1000 (264)

4000 (8800)

* Can be built to customer specification on request.

www.hydrolinkgroup.com

HL-

F-09

09/0

14.0

1

Page 15: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

SPECIFICATION

APPLICATIONS

Wire line coiling and de-coilingCable maintenance and inspectionInstallation of cables at well locations

www.hydrolinkgroup.com

Load Capacity - Ton

Speed - rpm

Max Reel Diameter - mm (in)

Working Pressure - bar (psi)

Flow - lpm (US gpm)

Hyd. Tank Capacity - L (US gal)

Weight - kg (lbs)

Drive

Application

HLGS-E-10-9268

10

10 to 35

2337 (92)

100 (1450)

37.5 (9.9)

150 (39)

2000 (4400)

Electric

Industrial

HLGS-E-12-9268-1

12

10 to 35

2337 (92)

100 (1450)

37.5 (9.9)

150 (39)

2000 (4400)

Electric

Industrial

HLFS-E-10-9268-1

10

20

2337 (92)

200 (2900)

12 (3.2)

150 (39)

3000 (6600)

Electric

Zone 1

HLFS-E-12-9268-1

12

20

2337 (92)

200 (2900)

11 (2.9)

150 (39)

3000 (6600)

Electric

Zone 1

HLFS-E-15-9268-1

15

20

2337 (92)

200 (2900)

11 (2.9)

150 (39)

3000 (6600)

Electric

Zone 1

HLFS-A-2-6037

2

4 to 20

1524 (60)

7 (101)

-

N/A

2200 (4840)

Pnumatic Motor

Zone 1

HLFS-D-12-9268-1

12

20

200 (2900)

11 (2.9)

150 (39)

3000 (6600)

Diesel Eng

Safe area / Zone 2

2337 (92)

Option Include

* Foot switch operation

* Full DNV certification

* Ask for any special requirements

HL-

F-09

09/0

15.0

1

Pneumatic, Electric or Diesel driven spooler units for cable maintenance and inspection (ground applications) or cable installation (field applications). The Hydrolink design ensures easy reel handling with a sliding motor assembly. Cylinders are fitted inside the box section for even lifting and field units are protected with wrap around bumpers.

Page 16: Hydrolink General Product Catalogue

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

www.hydrolinkgroup.com

SPECIFICATION

Pressure - bar (psi)

Flow - lpm (US gpm)

Power - kW (hp) *Water Tank - L (US gal)

Fuel Tank - L (US gal)

Length - mm (in)

Width - mm (in)

Height - mm (in)

Weight - kg (lbs)

2500 (36250)

23 (6)

110 (147)

350 (91)

650 (168)

2700 (106)

1380 (54)

2326 (91)

4000 (8800)

2750 (39875)

26 (7)

137.5 (184)

350 (191)

650 (168)

3000 (118)

1600 (63)

2150 (84)

4500 (9900)

2000 (29000)

40 (10.6)

154 (206)

350 (191)

650 (168)

3000 (118)

1800 (71)

3000 (118)

4500 (9900)

2800 (40600)

46 (12)

248 (332)

350 (191)

650 (168)

3000 (118)

1800 (71)

3000 (118)

4500 (9900)

UHP-24-K10016A-23-D119

UHP-24-UH210-26-D190

UHP-24-K16018-40-D174-TM-SA

UHP-24-K25019A-46-D280

* Quoted power requirement based upon 87.5% efficiency.

HYDROLINKULTRA HIGH PRESSUREPUMPS

HL-

F-09

09/0

16.0

1

Hydrolink design and build High Pressure (HP) and Ultra High Pressure (UHP) pump units in standard surface preparation configurations or custom designed to end user requirements. All Hydrolink pump units are designed for extreme conditions and are ideal for the Marine, Offshore and Oil & Gas markets.

Surface preparationConcrete demolitionHydrostatic testingTube bundle cleaningFluid Transfer

APPLICATIONS

ABOVE 1800 Bar

Page 17: Hydrolink General Product Catalogue

www.hydrolinkgroup.com

JEBEL ALI - Headquarters P.O. Box 18502, Dubai, UAE Tel: +971-4-8861414 • Fax: +971-4-8861413 e-mail: [email protected]

Hydrolink offer Fire Fighting Pump Sets to full FiFi I rating. We supply complete fire fighting solutions including Fire Fighting Pump Sets, Water and Foam Monitors, Foam Pumps, Drenching Pumps and Control Systems.

Our systems can be supplied with ABS / DNV / BV approval.

Standby fire fightingTankersOil rigsSupply vessels

Can be bui l t to customer speci f icat ion on request*Duty Point

SPECIFICATIONCH-F-D522/1200-12 CH-F-D157/HSP-12CH-F-D1300/2400-12

Impeller - mm (in)

Casing

*Pressure - bar (psi)

Flow - m³/hr (US gpm)

Power - kW (hp)

Length - mm (in)

Width - mm (in)

Height - mm (in)

Fuel Tank - ltrs (US gal)

520 (20.5)

Split Case

12 (174)

2400 (10565)

1291 (1721)

4800 (189)

1850 (73)

2910 (115)

2800 (739)

486 (19.1)

Split Case

12 (174)

1200 (5282)

580 (773)

4000 (157)

1800 (71)

2620 (103)

2000 (528)

400 (15.7)

End Suction

12 (174)

150 (660)

174 (232)

2400 (95)

1200 (47)

1800 (71)

380 (100)

APPLICATIONS

HL-

F-09

09/0

05.0

1