Evikon MCI OÜ Teaduspargi 7, Tartu, 50411 Estonia Tel +372 7336310 [email protected] www.evikon.eu Sensor Technologies Measurement & Control Instrumentation Hydrogen Sulfide Detector-Transmitter E2608-H2S Features Wall-mount or duct-mount version Industrial IP65 housing Two relays for alarm / ventilation control Two analog outputs settable to 4-20 mA or 0-10 V RS485 Modbus RTU digital interface Attached or remote sensor Specifications Calibration Hydrogen Sulfide H2S Sensing method Electrochemical cell Sampling method Diffusion Typical detection range 0...100 ppm 0...2000 ppm Maximum overload 500 ppm nd Resolution 0,1 ppm 2 ppm Response time T90 < 30 seconds < 25 seconds Output scale 0-1000 0-1000 Operating temperature -30...+50 °C -40...+50 °C Signal update every 1 second Response time < 30 seconds Maintenance interval 6 months Sensor lifetime > 2 years Self-diagnostics Full functionality check at start-up Warm-up time 1 min Power supply 11...30 VDC or 90...265 VAC Power consumption < 2 VA Digital interface RS485, Modbus RTU protocol Analog outputs 2 × 4-20 mA / 0-10 V, user settable Output relays 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max Default alarm set-points for 0...100 ppm range: RE1 (LOW): set 10; release 8 ppm RE2 (HIGH): set 20; release16 ppm for 0...2000 ppm range: defined by user Enclosure Light grey ABS plastic, wall mount, protection class IP65 Dimensions H85 × W82 × D55 mm Remote sensor probe protection IP65, shielded cable default cable length 3.0 m Operating environment industrial indoor and outdoor locations Operating conditions 15...90 %RH, atmospheric pressure ±10%; non ATEX rated areas Ask for other versions or custom designed products 0 Wall mount version Duct mount version Remote probe Connection diagram 4-20 mA / 0-10 V 4-20 mA/0-10 V 0V / GND OU T1 OU T2 0V A B R S485 +U = 11.. .30 VDC RE1 R E2 Fieldbus 24VDC S N L 90... 265 VAC J2 - OUT2 type J1 - OUT1 type J3 - return to fac tory sett ings Cont rol LED J1 J2 55 200 M16 Ø35 20 3 M25 35 82 87

Upload: others

Post on 29-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Hydrogen Sulfide Detector-Transmitter E2608-H2S 0 · RE2 (HIGH): set 20; release16 ppm for 0...2000 ppm range: defined by user (within 5-95% of the detection range) Other options:

Evikon MCI OÜ • Teaduspargi 7, Tartu, 50411 Estonia • Tel +372 7336310 • [email protected] • www.evikon.eu

Sensor TechnologiesMeasurement & Control Instrumentation

Hydrogen SulfideDetector-TransmitterE2608-H2S

Features

Wall-mount or duct-mount version

Industrial IP65 housing

Two relays for alarm / ventilation control

Two analog outputs settable to 4-20 mA or 0-10 V

RS485 Modbus RTU digital interface

Attached or remote sensor

Specifications

Calibration Hydrogen Sulfide H2S

Sensing method Electrochemical cell

Sampling method Diffusion

Typical detection range 0...100 ppm 0...2000 ppmMaximum overload 500 ppm ndResolution 0,1 ppm 2 ppmResponse time T90 < 30 seconds < 25 secondsOutput scale 0-1000 0-1000Operating temperature -30...+50 °C -40...+50 °C

Signal update every 1 second

Response time < 30 seconds

Maintenance interval 6 months

Sensor lifetime > 2 years

Self-diagnostics Full functionality check at start-up

Warm-up time ≤ 1 min

Power supply 11...30 VDC or 90...265 VAC

Power consumption < 2 VA

Digital interface RS485, Modbus RTU protocol

Analog outputs 2 × 4-20 mA / 0-10 V, user settable

Output relays 2 × SPST relays (closing contact),250 VAC / 30 VDC, 5 A max

Default alarm set-points for 0...100 ppm range:RE1 (LOW): set 10; release 8 ppmRE2 (HIGH): set 20; release16 ppmfor 0...2000 ppm range:defined by user

Enclosure Light grey ABS plastic, wall mount,protection class IP65

Dimensions H85 × W82 × D55 mm

Remote sensor probe protection IP65,shielded cabledefault cable length 3.0 m

Operating environment industrial indoor and outdoor locations

Operating conditions 15...90 %RH,atmospheric pressure ±10%; non ATEX rated areas

Ask for other versions or custom designed products

0

Wall mount version

Duct mount version

Remote probe

Connection diagram

4-20 mA/0-10 V4-20 mA/0-10 V

0V / GND

OUT1OUT20VAB

RS485

+U = 11.. .30 VDC

RE1

RE2

Fieldbus

24VDC

S

NL 90...265 VAC

J2 - OUT2 typeJ1 - OUT1 type

J3 - return to factory sett ings

Cont rol LED

J1 J2

5520

0

M16

Ø35

203

M25

35

8287

Page 2: Hydrogen Sulfide Detector-Transmitter E2608-H2S 0 · RE2 (HIGH): set 20; release16 ppm for 0...2000 ppm range: defined by user (within 5-95% of the detection range) Other options:

Evikon MCI OÜ • Teaduspargi 7, Tartu, 50411 Estonia • Tel +372 7336310 • [email protected] • www.evikon.eu

Sensor TechnologiesMeasurement & Control Instrumentation

Hydrogen Sulfide DetectorE2613-H2S

FeaturesMaintenance free sensor

SPDT relay for alarm / ventilation control

Range of compact wall mount enclosures

Low cost for volume HVAC applications

Specifications

Sensor type Electrochemical

Sampling method Diffusion

Detection range 0-10 / 0-50 ppm

Sensor protection Microporous PTFE dust filter

Warm-up time ≤ 1 min

Typical response time ≤ 30 s

Relay output switch-over contact (SPDT),250 VAC / 30 VDC, 5 A max

Power supply 12...30 VDC

Power consumption < 1 W

Sensor lifetime < 2 years

Indoors enclosure White, ivory or black ABS plastic,option -IP20 wall mount, protection class IP20

Weatherproof enclosure Light or dark grey ABS plastic,option -IP65 wall mount, protection class IP65

for IP20 enclosure: no condensation

Operating conditions -30 to 50 C (-20 to 40 C continuous);0 to 100% RH (15 to 95% continuous)atmospheric pressure ±10%

EMC Emissions to EN 61000-6-3, EN 61326-1

EMC Immunity to EN 61000-6-1, EN 61000-6-2

NOTE: The sensor may ehxibit considerable sensitivity to SO2, O3, NO,NO2, Cl2

IP20 orIP65

0

Ask for other versions or custom designed products

IP20 Enclosure

IP65 Enclosure

52

50

70

36

70

52

50

66

80

36

2771

71

Page 3: Hydrogen Sulfide Detector-Transmitter E2608-H2S 0 · RE2 (HIGH): set 20; release16 ppm for 0...2000 ppm range: defined by user (within 5-95% of the detection range) Other options:

Evikon MCI OÜ • Teaduspargi 7, Tartu, 50411 Estonia • Tel +372 7336310 • [email protected] • www.evikon.eu

Sensor TechnologiesMeasurement & Control Instrumentation

Hydrogen Sulfide TransmitterE2615-H2S

FeaturesMaintenance free sensor

User selectable output 4-20 mA / 0-10 V

Range of compact wall mount enclosures

Low cost for volume HVAC applications

Specifications

Sensor type Electrochemical

Sampling method Diffusion

Detection range 0-10 / 0-50 ppm

Sensor protection Microporous PTFE dust filter

Warm-up time ≤ 1 min

Typical response time ≤ 30 s

Analog output 4-20 mA / 0-10 V, user settable

Power supply 12...30 VDC

Power consumption < 1 W

Sensor lifetime < 2 years

Indoors enclosure White, ivory or black ABS plastic,option -IP20 wall mount, protection class IP20

Weatherproof enclosure Light or dark grey ABS plastic,option -IP65 wall mount, protection class IP65

for IP20 enclosure: no condensation

Operating conditions -30 to 50 C (-20 to 40 C continuous);0 to 100% RH (15 to 95% continuous)atmospheric pressure ±10%

EMC Emissions to EN 61000-6-3, EN 61326-1

EMC Immunity to EN 61000-6-1, EN 61000-6-2

NOTE: The sensor may ehxibit considerable sensitivity to SO2, O3, NO,NO2, Cl2

4-20 mAor 0-10 V

IP20 orIP65

0

Ask for other versions or custom designed products

IP20 Enclosure

IP65 Enclosure

2771

71

+UOUT0V

+24V0V

E2615Power Supply

+-

Controller

100...250 Ohm

4-20 mA

+UOUT0V

+24V0V

E2615Power Supply

+-

Controller

>250 kOhm

0/2-10 V

Two-wire current loop connection

Three-wire voltage output connection

52

50

70

36

70

52

50

66

80

36

Page 4: Hydrogen Sulfide Detector-Transmitter E2608-H2S 0 · RE2 (HIGH): set 20; release16 ppm for 0...2000 ppm range: defined by user (within 5-95% of the detection range) Other options:

Evikon MCI OÜ • Teaduspargi 7, Tartu, 50411 Estonia • Tel +372 7336310 • [email protected] • www.evikon.eu

Sensor TechnologiesMeasurement & Control Instrumentation

Hydrogen Sulfide TransmitterE2618-H2S

FeaturesAccurate and stable measurement

Wall mount or duct-mount robust enclosure

Remote probe option

Two analog outputs settable to 4-20 mA or 0-10 V

RS485 Modbus RTU digital interface

LCD indicator option

Specifications

Calibration Hydrogen Sulfide H2S

Sensor type Electrochemical cell

Sampling method Diffusion

Typical detection range 0...100 ppm 0...2000 ppmMaximum overload 500 ppm ndResolution 0,1 ppm 2 ppmResponse time T90 < 30 seconds < 25 secondsOutput scale 0-1000 0-1000Operating temperature -30...+50 °C -40...+50 °CSignal update every 1 second

Maintenance interval 12 months

Sensor lifetime > 2 years

Self-diagnostics Full functionality check at start-up

Warm-up time ≤ 1 min

Power supply 11...30 VDC / 24 VAC

Power consumption < 2 VA

Digital interface RS485, Modbus RTU protocol

Analog outputs 2 × 4-20 mA / 0-10 V, user settable

Enclosure Light grey ABS plastic,protection class IP65

Dimensions H82 × W80 × D55 mm

Remote sensor probe Protection IP65,shielded cabledefault cable length 3.0 m

Operating environment Industrial indoor and outdoor areas

Operating conditions 15...90 %RH,atmospheric pressure ±10%; non ATEX rated areas

LCD indicator optionOperating temperature 0...+50 °C,Display dimensions 72 × 36 mmNumber of digits 3.5 7-segmentCharacter height 14 mmOther features Backlight

55200Ø28203

M2534

50

Ø4 mm

55 80

130

8 2

M25

70

0

Wall-mount version

Duct-mount version

Connection diagram

Remote probe

36

77

Ø35...36 Ø50

120°

Ø65

80 327

Ø34 max

Hole

35

200

M1680

Ø35

203

M25

35

82

55

Page 5: Hydrogen Sulfide Detector-Transmitter E2608-H2S 0 · RE2 (HIGH): set 20; release16 ppm for 0...2000 ppm range: defined by user (within 5-95% of the detection range) Other options:

Evikon MCI OÜ • Teaduspargi 7, Tartu, 50411 Estonia • Tel +372 7336310 • [email protected] • www.evikon.eu

Sensor TechnologiesMeasurement & Control Instrumentation Revision 12.12.2018

Hydrogen Sulfide Detector-TransmitterE2638-H2S

FeaturesAccurate and stable measurement

Easy to install robust enclosure

Remote probe option

Two analog outputs settable to 4-20 mA or 0-10 V

RS485 Modbus RTU digital interface

Relay option

LCD indicator option

Specifications

Calibration Hydrogen Sulfide H2S

Sensor type Electrochemical cell

Sampling method Diffusion

Typical detection range 0...100 ppm 0...2000 ppmMaximum overload 500 ppm ndResolution 0,1 ppm 2 ppmResponse time T90 < 30 seconds < 25 secondsOutput scale 0-1000 0-1000Operating conditions -30...+50 °C -40...+50 °C

Signal update Every 1 second

Maintenance interval 6 months

Sensor lifetime > 2 years

Self-diagnostics Full functionality check at start-up

Warm-up time ≤ 1 min

Power supply 11...30 VDC / 24 VAC

Power consumption < 2 VA

Digital interface RS485, Modbus RTU protocol

Analog outputs 2 × 4-20 mA / 0-10 V, user settable

Enclosure Grey ABS plastic,protection class IP65

Dimensions H90 × W145 × D55 mmH140 with cable glands

Operating environment Industrial indoor and outdoor areas

Operating conditions 15...90 %RH,atmospheric pressure ±10%;non ATEX rated areas

RS485Modbus

4-20 mA0-10 VIP65

0

LCDindicator

option

145

115

90 65

~14

0

55130

E2638

30 M 61

M25

Dimensions

Connection diagram

OUT1OUT20VAB+U

J3

J1 J2

Fieldbus

Controller

SupplyPower

Control LED

Input 1 4-20 mA / 0-10 VInput 4-20 mA / 0-10 V2

0V / GND

0V

+24V

J1: OUT1 type (open: 4-20 mA; closed: 0-10 V)J : OUT type2 2 (open: 4-20 mA; closed: 0-10 V)J : 3 return to factory settings

SENSOR

Page 6: Hydrogen Sulfide Detector-Transmitter E2608-H2S 0 · RE2 (HIGH): set 20; release16 ppm for 0...2000 ppm range: defined by user (within 5-95% of the detection range) Other options:

Evikon MCI OÜ • Teaduspargi 7, Tartu, 50411 Estonia • Tel +372 7336310 • [email protected] • www.evikon.eu

Sensor TechnologiesMeasurement & Control Instrumentation Revision 12.12.2018

Additional options

Remote sensor probe Protection IP65,shielded cabledefault cable length 3.0 m

Relay outputs

Output relays 2 × SPST relays (closing contact),250 VAC / 30 VDC, 5 A max

Default alarm set-points for 0...100 ppm range:RE1 (LOW): set 10; release 8 ppmRE2 (HIGH): set 20; release16 ppmfor 0...2000 ppm range:defined by user

Visual alarm Red and green LEDs (option)

Acoustic alarm Buzzer 85 dB (option)

Power supply mains 90...265 VAC power unit(option)

LCD indicatorOperating temperature 0...+50 °C,Display dimensions 72 × 36 mmNumber of digits 3.5 7-segmentCharacter height 14 mmOther features BacklightNote: only one analog output is available for a version with LCD

35

36

77

80Ø

65

3

Ø 3 5 ...3 6 Ø50

120°

27

Ø34 m ax

Hole

Remote probe

Connection diagram for relay version

4-20 mA / 0-10 V4-20 mA / 0-10 V

0V / GND

OUT1OUT20VAB

RS485

+U = 11...30 VDC

RE 1

RE2

Fie ldbus

24 VDC

S

NL

90...265 VAC

J 3

Control LED

J1 J 2

J1: OUT1 type (open: 4-20 mA; closed: 0-10 V)J : OUT type2 2 (open: 4-20 mA; closed: 0-10 V)J : 3 return to factory settings

LCD indicator option

Page 7: Hydrogen Sulfide Detector-Transmitter E2608-H2S 0 · RE2 (HIGH): set 20; release16 ppm for 0...2000 ppm range: defined by user (within 5-95% of the detection range) Other options:

Evikon MCI OÜ • Teaduspargi 7, Tartu, 50411 Estonia • Tel +372 7336310 • [email protected] • www.evikon.eu

Sensor TechnologiesMeasurement & Control Instrumentation

Hydrogen Sulfide Detector-TransmitterE2648-H2S

FeaturesAccurate and stable measurement

Wall mount robust enclosure

Two analog outputs settable to 4-20 mA or 0-10 V

RS485 Modbus RTU digital interface

Relay option

Remote probe option

Specifications

Calibration Hydrogen Sulfide H2SSensor type Electrochemical cellSampling method Diffusion

Typical detection range 0...100 ppm 0...2000 ppmMaximum overload 500 ppm ndResolution 0,1 ppm 2 ppmResponse time T90 < 30 seconds < 25 secondsOutput scale 0-1000 0-1000Operating temperature -30...+50 °C -40...+50 °CSignal update Every 1 secondMaintenance interval 6 monthsSensor lifetime > 6 yearsSelf-diagnostics Full functionality check at start-upWarm-up time ≤ 1 minPower supply 11...30 VDC / 24 VAC

Option: 90...265 VAC power unitPower consumption < 2 VADigital interface RS485, Modbus RTU protocolAnalog outputs 2 × 4-20 mA / 0-10 V, user settableEnclosure Die-cast aluminium, wall mount,

protection class IP66Dimensions H101 × W101 × D58 mm

(overall H~150 × W101 × D55 mm)Operating environment Industrial indoor and outdoor areasOperating conditions 15...90 %RH,

atmospheric pressure ±10%; non ATEX rated areas

Relay outputs (option)

Output relays 2 × SPST relays (closing contact),250 VAC / 30 VDC, 5 A max

Default alarm set-points for 0...100 ppm range:RE1 (LOW): set 10; release 8 ppmRE2 (HIGH): set 20; release16 ppmfor 0...2000 ppm range:defined by user(within 5-95% of the detection range)

Other options:Remote sensor probe Protection IP65,

shielded cable, default length 3.0 m

55200203 M2534

0

IP66 4-20 mA0-10 V

RS485Modbus

Dimensions

Connection diagrams

Remote probe

30101

M16

M25

58

101

80

79

47

9

OUT1OUT20VAB+U

J3

J1 J2

Fieldbus

Controller

SupplyPower

Control LED

Input 1 4-20 mA / 0-10 VInput 4-20 mA / 0-10 V2

0V / GND

0V

+24V

J1: OUT1 type (open: 4-20 mA; closed: 0-10 V)J : OUT type2 2 (open: 4-20 mA; closed: 0-10 V)J : 3 return to factory settings

SENSOR

35

36

77

Ø 3 5 ...3 6 Ø50

120°

Ø6

580 3

27

Ø34 m ax

Hole

4 -20 mA / 0-10 V4-20 mA / 0-10 V

0V / GNDOUT1OUT20VAB RS485+U = 11...30 VDC

RE1

RE2

Fieldbus

24 VDC

S

NL 90...265 VAC

J3

LED1

J1J1 UT1 type: O (open: 4-20 mA; closed: 0-10 V)J UT type2: O 2 (open: 4-20 mA; closed: 0-10 V)J3: return to factory settings

LED2

LED1: device status controlLED2: power indication**only for enclosures with LED indicators

J2