hydraulic power pack · pdf filehydraulic power pack hydraulikaggregat 2014. mc4 2 mc 4 mc4...
TRANSCRIPT
MC4
Technical Catalogue
June
HYDRAULIC POWER PACK
HYDRAULIKAGGREGAT
2014
MC4
2
MC 4
MC4
modular power-packs were engineered to provide a practical and economical solution to various hydraulic
applications. Modularity concept allows us to use standare components manufactured in large quantities.The high
quality of components and their great mounting ease makes power pack extremely flexible and ready to cover a wide
range of power requirements. Every component is completely interchangeable and it can be stocked separately and
used in all required systems,obtaining in this way a time and stock costs save.
The result is a silent compact assembly with high performance which has large application possibilities in all industrial
fields.
Die Kleinaggregate der Baureihe " " sind das Ergebnis unserer langjährigen Erfahrung. Sie wurden entwickelt, um
praktische und wirtschaftliche Lösungen für die verschiedene Problemstellungen der Hydraulik-Automation
anzubieten. Das Baukastensystem besteht aus Standard-Komponenten, die in unserem Werk in großen Stückzahlen
hergestellt werden.Diese Komponenten stellen aufgrund Ihrer hohen Qualität eine einfache Montage und zuverlässige
Funktion sicher. Durch den modularen Aufbau und die Austauschbarkeit der Elemente untereinander können die
Kleinaggregate für verschiedene Hydraulik-Systeme und auch auf vorhandenen Ölbehältern verwendet werden. Das
geringe Laufgeräusch der Pumpen erlaubt einen störungsarmen Einsatz in allen Industriebereichen.
Das Baukastensystems ermöglicht außerdem eine zeitplatz-und kostensparende Lagerthaltung der Komponenten.
3
1° 2° 3° 4°
1° 2° 3° 4°
MC4
203
156
109
82M10
54
134
134
B
A
C
D
E
F
G
H
L
M
N
P
V
R
K
S
U
SCHEMATIC SCHEMATIC SCHEMATIC
SCHEMATIC
MOUNTING SEQUENCE
MOUNTING SEQUENCE
ANORDNUNG
ANORDNUNG
DESCRIPTION DESCRIPTION DESCRIPTION
DESCRIPTION
BESCHREIBUNG BESCHREIBUNG BESCHREIBUNG
BESCHREIBUNG
1/4" PARALLELOPENED
1/4"ZWISCHENPLATTE
1/4" CLOSED
1/4" SERIE OPENED
3/8" SERIE OPENED
1/4" ENDPLATTE
1/4" MITTELPLATTE
3/8" MITTELPLATTE
1/4" GAUGEPORT
1/4" ENDPLATTE MITMANOMETERANSCHLUß
3/8" ENDPLATTE MITMANOMETERANSCHLUß
3/8" PARALLELOPENED
3/8"ZWISCHENPLATTE
3/8" CLOSED
3/8" GAUGEPORT
PILOT CHECKVALVE ON "A" PORT
MIT ENTSPERRBAREMRV IN "A"
3/8" ENDPLATTE
ADJUSTABLE PRESSUREON "A" AND "B" PORTS
ADJUSTABLE PRESSUREON "B" PORT
ADJUSTABLE PRESSUREON "A" PORT
MIT DBV IN "A" UND "B"
HAND PUMP
BLOCK N.13
MIT HANDPUMPE
STEUERBLOCK N.13
HIGHTENING PLATEh=29 NECESSARYFOR AC MOTOR M-N-P
HEBEPLATTE h=29NOTWENDIG FUEREL-MOTOREN -M-N-P
MIT DBV IN "B"
MIT DBV IN "A"
PILOT CHECKVALVE ON "B" PORT
MIT ENTSPERRBAREMRV IN "B"
PILOT CHECK VALVEON "A" AND "B" PORTS
MIT ENTSPERRBAREMRV IN "A" UND "B"
MA
NIF
OL
D B
LO
CK
S F
OR
CE
TOP
3 S
OL
EN
OID
VALV
ES
(U
NI I
SO
440
1-A
B-0
3-4)
AN
SC
HLU
ßB
LÖC
KE
FÜ
R C
ETO
P3
VE
NT
ILE
(U
NI I
SO
440
1 -
AB
- 0
3 -
4)
SCHALTSYMBOL SCHALTSYMBOL SCHALTSYMBOL
SCHALTSYMBOL
MOUNTING BLOCKS
STEUERBLÖCKE
6 cm³/Hub
4
1
2A
B
C
35-90 bar
75-190 bar
160-290 bar
V
1
50 bar
150 bar
180 bar
2
3
3
95
95
125,5
WITH SEALED CAPMIT SICHERUNGSKAPPE
WITH PROTECTION CAPMIT SCHUTZKAPPE
WITH HAND WHEELMIT HANDRAD
PRESSURE RANGE
EINSTELLBEREICH
STANDARD SETTING
STANDARD EINSTELLUNG
RELIEFVALVES
DRUCK BEGRENZUSVENTIL
5
12Volt DC 0,5 kW
24Volt DC 0,5 kW
12Volt DC 0,8 kW
24Volt DC 0,8 kW
12Volt DC 1,6 kW
24Volt DC 2,2 kW
24Volt DC 3,0 kW
D1 L1
78
78
114
125
HF
HE
GU
GZ
EN
ES
FB
154,9
154,9
158
207,5
2345678
1
M
0 5 6 7 8
63
71
80
90
100/112
kW kW kW
0,18-0,25
0,37-0,55
0,75-1,1
1,5-2,2
3-5,5
0,12-0,18
0,25-0,37
0,55-0,75
1,1-1,5
2,2-4
0,09-0,12
0,18-0,25
0,37-0,55
0,75-1,1
1,5-2,2
B14
RLMNP
5
67
8
19,5
19,5
30,5
40,5
75
X
1 5
4 8
2 6
3 7
P (T)
D1
40L1
Z Z
Gr1
Gr0,5
42,8
42
53
63
81,5
62,7
42
53
-
-
Z
40X
P (T)
R
1
7
11
125
125
0
52
P(T)30
ABCDJEFGLMNPHTRS
P
0,25
0,45
0,56
0,75
0,92
1,2
1,7
2,2
2,6
3,2
3,8
4,3
4,8
6,0
7,8
9,8
0,5
1
PUMPS DISPLACEMENT
PUMPENGRÖßEN
P (T) BSP G 3/8" without holes for blocks mounting
Mounting foot -
1/4" Auxiliary return port -
Auxiliary pressure port -
Befestigungsfuß
1/4" Zusatz-Ablaßstropfen
Zusätzlicher Anschluß
With M6 holes for blocks mountingMit Bohrungen M6 fuer die Bloeckemontage
NOMINALDISPLACEMENT
CC/REV
FÖRDERVOLUMENNOMINAL cm.³/U
PUMPGROUP
BAUGRÖßE
OPTIONS
OPTIONEN
TYPETYP
DC MOTORS - GLEICHSTROMMOTORE
CONTACT BREVINI FLUID POWER TO CHECK THE OPERATING DATAKONTAKT BREVINI FLUID POWER ZUR ÜBERPR DER BETRIEBSDATENÜFUNG
DC - AC MOTORS
ELEKTROMOTORE DC/AC
START SWITCHPOSITION
POSITION DESSTARTRELAIS
TERMINAL POSITIONWITHOUT START SWITCH
POSITION DER POLEOHNE STARTRELAIS
FRAMEBAUFORM
THERMAL SWITCH PROTECTION AND FAN COOLED MOTORS ARE AVAILABLEMOTORE AUCH MIT THERMOSCHALTER UND LUFTER VERFÜGBAR
AC MOTORS
DREH - WECHSELSTROMMOTORE
SIZE
BAUGRÖßE
WITHOUT MOTOR - OHNE MOTOR
2 POLES 4 POLES 6 POLES
P (T) BSP G 3/8" ohne Bohrungen fuer die Bloeckemontage
P - (T)
37
T
Ø 1
23
A
01
02
03
A141
200
330
25
B
05
06
08
B
246
308
370
50
Ø 1
75
242
180
45°
180
180
150
308
180 80
.1
80.1
45°
273
Ø 2
17
~ 3
0
200
80 22
285
174
207 7
178
215 37
142,5
22
154
37
Ø11 N°4 holes
72
130
133 22
110
350
25
22
230
80 220
Ø11 N°4 holes72
Ø 2
17
~ 3
0
367
219
20
102
8 350 8
94
N°4 holes11x30
220366
462
= =
278
300
105
255
250
200
506
Ø 16,5N°4 holes
46
474
46
281
255
35
4660
35
506
436
474
100
46Ø 16,5N°4 holes
1
0
F
2345
3
P
4
25
3
4
5
2
1 25
25
14120910
07P07P05
75
250
200
60
P
P - (T)
1
01 02 03 05 P05 06 07 P07 08 09 10 12 14 25
2 3 5 6 7 8 9 10 12 14 25
6
VERTICALWITHOUT TANK
SENKRECHTOHNE BEHÄLTER
SENKRECHT
NOMINALCAPACITY
NENNVOLUMEN
SPECIAL SIZES ONREQUEST
SONDERGRÖßEN AUFANFRAGE
MOUNTING POSITION
MONTAGESCHLÜSSEL
HORIZONTAL
VERTICAL
WAAGERECHT
TANKS
BEHÄLTER
7
M T F
R
L
M
N
P
0
5
6
7
8
1
2
3
4
5
01
02
03
05
P05
06
07
P07
08
09
10
12
14
25
1
2
3
4
5
6
7
8
HF
HE
GU
GZ
EN
ES
FB
Gr. 63
Gr. 71
Gr. 80
Gr. 90
Gr. 100
12Volt 500W
24Volt 500W
12Volt 800W
24Volt 800W
12Volt 1600W
24Volt 2200W
24Volt 3000W
A
V
A
B
C
D
J
E
F
G
L
M
N
P
H
T
R
S
0,45
0,25
0,56
0,75
0,92
1,2
1,7
2,2
2,6
3,2
3,8
4,3
4,8
6,0
7,8
9,8
PMC4
B
C
D
E
F
G
H
L
M
N
P
R
S
V
K
U
R
11
2
A
B
C
75-190 bar
35-90 bar
160-290 bar
3
0
Horizontal
AC motors - Wechselstrom-Motore
DC motor mountingposition without
start switch
Position der pole ohneStartrelais
AC motorposition
mounting
Einbaulage
DC motors - Gleichstrom-Motore
DC motor mountingposition with start switch
Position desStartrelais
Options - Optionen
Nominaldisplacement
cc/rev.
Fördervolumennominalcm³/U
Waagerecht
VerticalSenkrecht
Nominalcapacity(litres)
Nennvolumen(Liter)
Vertical without tankSenkrecht ohne Behälter
Protection capSchutzkappe
Sealed capSicherungskappe
Pressurerange
Einstellbereigh
Hand wheelHandrad
1/4" PARALLEL INTERMEDIATE SUBPLATE1/4" ZWISCHENPLATTE
1/4" SERIE INTERMEDIATE SUBPLATE1/4" MITTELPLATTE - SERIE
1/4" PARALLELTOP BLOCK1/4" ENDPLATTE
1/4" PARALLELTOP BLOCK WITH GAUGE PORT1/4"ENDPLATTE MIT MANOMETERANSCHLUß
3/8" PARALLEL INTERMEDIATE SUBPLATE3/8" ZWISCHENPLATTE
3/8" SERIE INTERMEDIATE SUBPLATE3/8" MITTELPLATTE
3/8" PARALLELTOP BLOCK3/8" ENDPLATTE
3/8" PARALLELTOP BLOCK WITH GAUGE PORT3/8" ENDPLATTE MIT MANOMETERANSCHLUß
PILOT CHECK ON "A" PORTMIT ENTSPERRBAREM RV IN "A"
PILOT CHECK ON "B" PORTMIT ENTSPERRBAREM RV IN "B"
PILOT CHECKS ON "A" AND "B" PORTSMIT ENTSPERRBAREM RV IN "A" UND "B"
ADJUSTABLE PRESSURE RELIEF ON "A" PORTMIT DBV IN "A"
ADJUSTABLE PRESSURE RELIEF ON "B" PORTMIT DBV IN "B"
ADJUSTABLE PRESSURE RELIEF ON "A" AND "B" PORTSMIT DBV IN "A" UND "B"
BLOCK N 13STEUERBLOCK N 13
HAND PUMPMIT HANDPUMPE 6 cm³/Hub
HIGHTENING PLATE h=29 NECESSARY FOR AC MOTOR M-N-PHEBEPLATTE h=29 NOTWENDIG FUER EL-MOTOREN -M-N-P
Mounting blocks / Steuerblöcke
ORDERING CODE
BESTELLSCHLÜSSEL
The validation of the central endhead follows a life-test with 250 bar pulsed pressure repeated for 100.000 cyclesNach Validierung der zentralen Anschlussblöcke folgt eine Belastungsprüfung bei 250 bar mit wiederholten Druckspitzen über 100.000 Lastspiele.
Brevini Fluid Power S.p.A.Via Moscova, 642124 Reggio Emilia - ItalyTel. +39 0522 270711Fax +39 0522 270660www.brevinifluiidpower.cominfo@ .combrevinifluiidpower
Code DOC00005 - Rev. 004