hydrapump mini rev 2.2the pump is designed to pump fresh water so please make sure that the water...
TRANSCRIPT
©CopyrightWatershedInnovations.Allrightsreserved HydraPumpMiniDocumentationRev2.2
1
HydraPump™Mini
Owner’sGuide
©CopyrightWatershedInnovations.Allrightsreserved HydraPumpMiniDocumentationRev2.2
2
NOTE: ThisWaterPumphasbeendesignedtooperateon110-120Volt,60
Hzexclusively.UsinganyothervoltageorHzadverselyaffectsperformance.
IMPORTANT:Keepthisguideforfuturereference.CAUTION: BesuretoreviewSAFETYINSTRUCTIONSFIRSTPERTAININGTOA
RISKOFFIRE,ELECTRICALSHOCKORINJURYTOPERSONSbeforeusingthepump.
• AbsorbentclothorHydraTowel™toforcleanupandmaintenance• Standardhosefortheoutlet,asmallhoseisprovidedfortheinlet
1piece-HydraPumpMini1piece–Plasticinletstrainer1piece–Shortinlethose1piece-repairandmaintenancekit
USAGEGUIDE
TOOLSANDMATERIALSYOUMAYNEED
PACKAGECONTENTS
©CopyrightWatershedInnovations.Allrightsreserved HydraPumpMiniDocumentationRev2.2
3
Makesureyourworkareawhereyouintendtousethepumpisclearofclutterandwelllit.Alsoensurethatthepumpisinalocationthatitwillnotbesubmergedorincontactwithexternalwater.Thepumpisdesignedtopumpfreshwatersopleasemakesurethatthewatersourcedoesnotcontainlargebitsofdebris.
INSTRUCTIONSPERTAININGTOARISKOFFIRE,ELECTRICSHOCKORINJURYTOPERSONS.SAVETHESEINSTRUCTIONS.WARNING–Whenusingelectricalpumps,basicprecautionsshouldalwaysbefollowed,includingthefollowing:
1. Readallinstructionsbeforeusingthepump.2. Toreducetheriskofinjury,closesupervisionisrecommendedatalltimes
thatthepumpisinoperation.3. Duringoperationthepumpmaybecomehot.Usethehandletomovethe
pumpandexercisecautionwhentouchingorhandlingthepump.4. Donotputfingersorhandsintoawaterpumpinletoroutletwhenoperating.5. Unplugthepowerbeforeattemptingtomovethepump.6. ForpropergroundinginstructionsseetheELECTRICALCONNECTION
portionofthismanual.
SITEPREPARATION
IMPORTANTSAFETYINSTRUCTIONS
©CopyrightWatershedInnovations.Allrightsreserved HydraPumpMiniDocumentationRev2.2
4
HOSECONNECTIONSConnectastandardgardenhosetotheoutletofthepump.Anarrowonthefrontofthepumpmarkstheoutlet.Usetheshortprovidedhosetoconnecttotheinletofthepump.Ifyouuseahoseotherthantheprovidedshorthosefortheinletconnect,insurethathosewillnotcollapsewhenpumpingbegins.Ifusingnon-suppliedinlethosepleasemakesureisnolongerthan25’longandthatitislessthan10’abovethewatersource.Note:Keepthehosesasstraightaspossibleandthiswillimprovetheefficiencyofthepump.
GROUNDINGINSTRUCTIONSThewaterpumpisequippedwithagroundedplug-inpowercord.Thispumpmustbegrounded.Intheeventofamalfunctionorbreakdown,groundingprovidesapathofleastresistanceforelectriccurrenttoreducetheriskofelectricshock.Thispumpisequippedwithacordhavinganequipment-groundingconductorandagroundingplug.Theplugmustbepluggedintoanappropriateoutletthatisproperlyinstalledandgroundedinaccordancewithalllocalcodesandordinances.�
ELECTRICALCONNECTIONSA. Connectpumpto110-120Volt,60HzACcurrentonly.B. Useathreeprongplug,seefigurebelow:
CAUTION:Donotallowthepump,electricalcord,orelectricaloutlettocomeintocontactwithwater.Thismayresultinseriousinjury.Ifunsureofhowtoinstallorusethispumpconsultalicensedelectrician.
WATERANDELECTRICALCONNECTIONS
©CopyrightWatershedInnovations.Allrightsreserved HydraPumpMiniDocumentationRev2.2
5
PUMPPREPARATIONBeforeoperating,thepumpshouldbeoiled.Thiswillallowforaneasieroperationontheself-primingprocessandcanincreasethelongevityoftheimpeller.Pourabout½tablespoonoffoodgradevegetableoilintotheinletofthepump.Thisshouldprovidethenecessarylubricationtotheimpeller.
OPERATIONThefollowingarethestepsforoperation
1. Afteroilingthepump,securelyattachinletandoutlethosestothepump.a. Theoutletislabeledonthefrontofthepumpandahoseshouldbe
connectedb. Thereisaprovidedshortinlethoseincludedwiththepumpandcan
beused.c. Thereisalsoaprovidedsuctionattachment(largetriangular
attachment,item20inthereferencepartslist).Thisisonlyrequiredtostopdebrisfrombeingsuckedupintothepumpandnotnecessaryforcleanwater.
2. Verifythatthepumpisplacedinasafeareaandwillnotbesubmergedor
comeincontactwithawatersource.Alsomakesurethatnothingistouchingthepumpsinceitmaybecomehotduringoperation.
3. Checkthattheinlethoseandsuctionattachment(ifrequired)areconnectedandarebeingfedbyawatersourcethatistobepumped
4. Makesuretheendoftheoutlethosesecurelyattachedandthattherearenokinksinthehose.
OPERATINGINSTRUCTIONS
©CopyrightWatershedInnovations.Allrightsreserved HydraPumpMiniDocumentationRev2.2
6
5. Carefullyplugthepumpintoa3-wire,120Volt,60Hz,groundedA.C.outlettobeginoperation.
6. Thepumpisself-primingandwatershouldbegintoflow30secondsorless.
a. Ifwaterdoesnotflowunplugthepumpandchecktheconnectionsandsetup.
b. Operatingthepumpwithoutwaterforanextendedperiodmaydamagethepumpandcauseittofail.
7. Oncepumpinghascompleted,unplugthepump.Thepumpmaybecomehotduringoperation.Becarefulwhenworkingnearortouchingthepump.Emptyandremoveboththeinletandoutlethoses.Wipethepumpcleanandstoreinacleananddryplacefornextuse.
CAUTION:Waterandelectricitydonotmix.Makesuretocontinuouslycheckthatthepowerconnectionsandcablesarenotincontactwithwater.Consultanelectricianifyouhaveanyquestionsorconcernabouttheelectricalcircuitorpumpoperations.
©CopyrightWatershedInnovations.Allrightsreserved HydraPumpMiniDocumentationRev2.2
7
Problem PossibleCauses PossibleSolutionsPumpwillnotstart 1. Nopowerorcord
notconnected1. Checkoutletpower
orpluginpumpPumpisonbutnowaterisflowing
1. Impellerisdry2. Inlethoseistoo
long3. Hoseskinked4. Pumpconnected
incorrectly
1. Oilpumpthroughinlet
2. Shortentheinlethose
3. Straightenoutthehoses
4. Makesureinletandoutlethosesarecorrect
Pumpstopswithoutwarning
1. Nowatertopump2. Pumphas
overheatedandthermaloverloadhastripped
3. Hoseshavebecomekinked
1. Checkinletwatersupply
2. Unplugandletthepumpcool
3. Straightenouthoses
Pumpleaks 1. HoseO-rings
missing1. Removeinletand
outlethosesandreinstall
CONTACTForadditionalquestionsorcommentspleasecontactWatershedInnovationsatthefollowing:Email:[email protected]:1(888)876-40689AMto5PM(M-F)Pacific
BEFOREEACHUSEInspectthegeneralconditionofthepump.Checkforloosescrews,misalignmentorbindingofmovingparts,crackedorbrokenparts,damagedelectricalwiring,andanyotherconditionthatmayaffectitssafeoperation.
AFTERUSEUnplugthepumpandletcool,asitmaybehotfromoperating.Removethehoseconnections.Carefullytiltanddrainallexcesswaterfrominsidethepump.Lastly,cleanexternalsurfacesofthepumpwithcleanclothorsponge.Storeinacleananddryplace.
TROUBLESHOOTING
CLEANINGANDMAINTENANCE
©CopyrightWatershedInnovations.Allrightsreserved HydraPumpMiniDocumentationRev2.2
8
• 1/10HP,SinglePhase120V~60Hz,2.3A• 3/4”Chrome-platedbronzesuction/dischargeconnectors.• Easy-carryhandleforportability.• 18AWGpowercord,6’long• Flow,pleaseseechartbelow:
SPECIFICATIONS
©CopyrightWatershedInnovations.Allrightsreserved HydraPumpMiniDocumentationRev2.2
9
Partslistreference(allitemsareincluded):No. Component No. Component1 M4*10Phil.Pinheadscrews 11 Rubberwasher2 Endcover 12 Motor3 Sealwasher 13 Brushcap4 Impeller 14 Brushandspringset5 M5*30Phil.Panheadscrews 15 Footpad6 Easy-carryhandle 16 M5*7Phil.Pinheadscrews7 Pumpbody 17 Serratedgasket8 Oilseal 18 Baseboard9 Woolfelt 19 Suctionattachment10 Feltclip 20 Inlethose
REFERENCEPARTSLIST