hybrid ip pbx. kx-tda100/200 kx-tda hybrid ip-pbx the ultimate solution for the seamless...
TRANSCRIPT
Hybrid IP PBXHybrid IP PBX
KX-TDA100/200KX-TDA100/200
KX-TDA Hybrid IP-PBXKX-TDA Hybrid IP-PBX
• The ultimate solution for the seamless synchronisation of voice and data.
• Vastly improved feature set and even greater ease of operation.
• Completely new architecture with Panasonic’s legendary reliability.
• Integrated DECT portable phones.
• PC-Phone and PC-Console via USB.
KX-TDA Hybrid IP-PBXKX-TDA Hybrid IP-PBX
• Advanced Networking.– Tie Lines– VPN– Q-Sig– VoIP
• Higher Call Centre functionality.
• Multi-connect CTI.
The Concept:
New Technology
New Customer NeedsQuick Development
HybridIP-PBX
xDSL
QSIG
Wireless
VoIP
Open Architecture
Expandability
New Architecture
WorldwideSoftware Ver.
Global Businessusing Internet
Call Centre withCTI / IVR / CRM
Unified MessagingVM/Fax-mail/E-mail
USB
Personal CTI
RemoteMaintenance
DPT
Wireless Data
LAN
H.323
Office CTI
CTI Client
IP Telephony
CTI Server
RemoteMaintenanceNetworking
Internet
PSTN/ISDN
Telephony Network IT Network
Hybrid ofTechnologies
Panasonic
Panasonic
Hybrid IP-PBXHybrid IP-PBX
Panasonic
Panasonic
SLT
Router
Convergence of Telephone & IT Networks
KX-TDA Line-upKX-TDA Line-up
TDA200 216 ports
TDA100 108 ports
TDA30 32 ports
KX-TDA System OutlineKX-TDA System Outline
• The Main Unit consists of a Basic Shelf that includes an MPR (Main Processor) card. * Power Supply must be ordered separately according to requirements.
• The ‘Free Slot’ architecture allows a wide variety of CO, Extension and other peripheral cards to be installed easily into the system’s remaining slots.
KX-TDA System OutlineKX-TDA System Outline
• The TDA200 can be configured to a maximum of 216 ports.– 128 Extns / 128 Lines max.
• The TDA100 can be configured to an absolute maximum of 108 ports.– 64 Extns / 64 Lines max.
KX-TDA ConfigurationsKX-TDA Configurations
TDA100 TDA200
Free Slot Architecture
KX-TDA System Capacity - 1KX-TDA System Capacity - 1
TDA200 TDA100 TDA30
10-slot10-slot 5-slot5-slot COCO
00 00 0-CO / 4-Hybrid port0-CO / 4-Hybrid portInitial ConfigurationInitial Configuration
1-slot1-slot 1-slot1-slotOptional Card SlotOptional Card Slot
Free Card SlotFree Card Slot
Medium (M)Medium (M) Small (S)Small (S)Power SupplyPower Supply
216216 108108 3636Max. PortMax. Port
2-slot [4-port]2-slot [4-port]
EXT.EXT.2-slot [8-port]
1-slot [4-port]
2-slot [8-port]
1-slot [4-port]
128128 6464 8 or 128 or 12Max. Trunk PortMax. Trunk Port
3232 1616 N/AN/AMax. E&M (Tie Line)Max. E&M (Tie Line)
128128 6464 88Max. CO (PSTN)Max. CO (PSTN)
4 (120-ch)4 (120-ch) 2 (60-ch)2 (60-ch) N/AN/AMax. PRI, Internal PRIMax. PRI, Internal PRI
64 (128-ch)64 (128-ch) 32 (64-ch)32 (64-ch) 6 (12-ch)6 (12-ch)Max. BRI, S0-BusMax. BRI, S0-Bus
4 (16-ch)4 (16-ch) 2 (8-ch)2 (8-ch) 1 (2-ch)1 (2-ch)Max. IP Gateway CardMax. IP Gateway Card
4 (120-ch)4 (120-ch) 2 (60-ch)2 (60-ch) N/AN/AMax. E1Max. E1
KX-TDA System Capacity - 2KX-TDA System Capacity - 2
TDA200 TDA100 TDA30
128128 6464 2424Max. D-PT including Digital XDPMax. D-PT including Digital XDP
32 (128 : Note2 )
32 (128 : Note2 )
16(32 : Note3 )
16(32 : Note3 )
4(24 : Note4 )
4(24 : Note4 )
Max. Old D-PT (Note-1 ) (T75/T74/T72 series)Max. Old D-PT (Note-1 ) (T75/T74/T72 series)
128128 6464 2828Max. ExtensionMax. Extension
32 (128-ch)32 (128-ch) 16 (64-ch)16 (64-ch) 4 (16-ch)4 (16-ch)Max. DECT-Cell StationMax. DECT-Cell Station
128128 6464 2424Max. SLTMax. SLT
128128 6464 2424Max. D-PT (T7600 series, T7565, T7560)Max. D-PT (T7600 series, T7565, T7560)
Note-1: An old DPT Consumes 4 times the power of a new DPT. Therefore, calculate 1 old DPT as 4 DPTs.Note-2: Requires Optional Power Supply L. Note-3: Requires Optional Power Supply M. Note-4: Requires Optional Power Supply SX.
216216 108108 3636Max. PortMax. Port
10-slot10-slot 5-slot5-slot 4-Hybrid port1 x 4-Port Slot2 x 8-Port Slot
4-Hybrid port1 x 4-Port Slot2 x 8-Port Slot
1-slot1-slot 1-slot1-slotOptional Card SlotOptional Card Slot
Free Card SlotFree Card Slot
KX-TDA System Capacity - 3KX-TDA System Capacity - 3
TDA200 TDA100 TDA30
1616 88 44Max. DoorphoneMax. Doorphone
22 22 11Max. TVP systemMax. TVP system
128128 128128 2424Max. DECT PS (Cordless)Max. DECT PS (Cordless)
1616 88 44Max. Door OpenerMax. Door Opener
Other AccessoriesOther Accessories
1616 88 N/AN/AMax. External RelayMax. External Relay
1616 88 N/AN/AMax. External SensorMax. External Sensor
3232 1616 44Max. DECT CS (Antenna)Max. DECT CS (Antenna)
1616 88 22Max. Voice MSG(OGM) Ch.Max. Voice MSG(OGM) Ch.
22 22 11Max. BGM / MOH InputMax. BGM / MOH Input
22 22 22Max. External PagingMax. External Paging
11 11 11Max. RS232C / SMDRMax. RS232C / SMDR
11 11 11Max. USBMax. USB
11 11 11Max. Ethernet For CTIor ProgrammingMax. Ethernet For CTIor Programming
Note : A DECT CS belongs to Extension Type and is counted as an Extension.
88 88 N/AN/AMax. PC ConsoleMax. PC Console
KX-TDA200/100KX-TDA200/100 MPR card
MPR : Main Processor card (Pre-installed)• Same unit for both TDA100 and TDA200
RMTRMTAnalogue ModemAnalogue Modem
RMTRMTAnalogue ModemAnalogue Modem
Serial I/F
SD Slot
USB I/F
MEXMEXExpansion MemoryExpansion Memory
MEXMEXExpansion MemoryExpansion Memory
Analogue Modem card (Optional)
- Max. 56K bps (V.90)
SD (Secure Digital) card (16 Mb Pre-installed) - System Software - Customer Data - Replaceable
- ISDN Remote Maintenance to update Main Software
USB Interface (Pre-installed)
- Programming / CTI
Expansion Memory card (Optional) - Available from Version 1.1 Software- Extension Capacity Expansion
RS232-C / V.24 Interface (Pre-installed)
- Programming / SMDR
KX-TDA200/100KX-TDA200/100 Trunk cards
Trunk cards (Optional) Installed in any “Free slot”
LCOT 8LCOT 8LCOT 16LCOT 16LCOT 8LCOT 8
LCOT 16LCOT 16
CID8/PAY8CID8/PAY8CID8/PAY8CID8/PAY8
8 or 16 Analogue CO card - Polarity Reversal
Caller ID card for 8CO (FSK/DTMF)12/16KHz Detection
E&M 8E&M 8E&M 8E&M 88 E&M card
- Type 5
BRI 4BRI 4
BRI 8BRI 8
BRI 4BRI 4
BRI 8BRI 8
4 or 8 Basic RateISDN card PRI 30PRI 30PRI 30PRI 30
1 Primary RateISDN card (30-ch)
- RJ45 / BNC
E1 (30-ch)E1 (30-ch)E1 (30-ch)E1 (30-ch)1 E1 card
- RJ45 / BNC IP-GW 4IP-GW 4IP-GW 4IP-GW 44 IP Gateway card
- 10 Base-T
- Occupies 2-slots
KX-TDA200/100KX-TDA200/100 Extension cards
Extension cards (Optional) Installed in any “Free slot”
DHLC8DHLC8DHLC8DHLC8
8 Digital Hybrid Line card
- Supports 8 DPT and 8 SLT, or 8 APT.
- 2 Power Failure port
- 8 DTMF Receiver
- XDP
- DXDP (from V1.1)
SLC8SLC8
SLC16SLC16
SLC8SLC8
SLC16SLC16
8 or 16 SLT Line card
- 2 or 4 Power Fail ports
- 8 or 16 DTMF Receivers
- 48V (1500m)
MSLC16MSLC16MSLC16MSLC1616 SLT with Message Lamp
- 90-Volt Neon Lamp
- 4 Power Fail ports
- 16 DTMF Receivers
CSINF4CSINF4
CSINF 8CSINF 8
CSINF4CSINF4
CSINF 8CSINF 8
4 or 8 DECT-CS Interface
- Cabling : Up to 1000 m
DLC 8DLC 8DLC 16DLC 16DLC 8DLC 8
DLC 16DLC 16
8 or 16 Digital Line card
- Cabling : 500 m
- DXDP (from V1.1)
KX-TDA200/100KX-TDA200/100 Optional cards
Option card Installed in “Option Slot” & any “Free slot”
OPB 3OPB 3OPB 3OPB 3Optional card mounting base board
- Houses 3 small optional cards MSG4 / DPH4 / EIO4 and ECHO16
CTI-LINKCTI-LINKCTI-LINKCTI-LINKCTI Interface Card
- 10 Base-T
MSG4MSG4MSG4MSG44-Ch. Message card
- Total 8 min. Max. 64 Msgs
DPH4DPH4DPH4DPH44 Doorphone /Door Opener card
EIO4EIO4EIO4EIO44 Sensor Input / 4 Relay Output card (Ver.1.1)
ECHO16ECHO16ECHO16ECHO1616-Ch. Echo Canceller card
- Suppresses echo signal
- Required for
1) Multiparty Conference from 5-party to 8-party (Especially for Analogue CO and SLT customers)
2) Analogue CO to CO Transfer
3) Network-based echo
TDA System ConfigurationTDA System Configuration - Cards & Slots
DHLC8DHLC8DLC8, DLC16DLC8, DLC16SLC8, SLC16SLC8, SLC16
DHLC8DHLC8DLC8, DLC16DLC8, DLC16SLC8, SLC16SLC8, SLC16
CSINF4CSINF4CSINF8CSINF8CSINF4CSINF4CSINF8CSINF8
TDA200TDA200TDA200TDA200 TDA100TDA100TDA100TDA100
Max. 8 CardsMax. 8 CardsMax. 8 CardsMax. 8 Cards Max. 4 CardsMax. 4 CardsMax. 4 CardsMax. 4 Cards
Max. 4 CardsMax. 4 CardsMax. 4 CardsMax. 4 Cards Max. 2 CardsMax. 2 CardsMax. 2 CardsMax. 2 Cards
TotalTotalTotalTotal Max. 8 CardsMax. 8 CardsMax. 8 CardsMax. 8 Cards Max. 4 CardsMax. 4 CardsMax. 4 CardsMax. 4 Cards
LCOT8, LCOT16LCOT8, LCOT16BRI4, BRI8, E1BRI4, BRI8, E1PRI30, E&M4PRI30, E&M4IP-GW4IP-GW4
LCOT8, LCOT16LCOT8, LCOT16BRI4, BRI8, E1BRI4, BRI8, E1PRI30, E&M4PRI30, E&M4IP-GW4IP-GW4
Max. 8 CardsMax. 8 CardsMax. 8 CardsMax. 8 Cards Max. 4 CardsMax. 4 CardsMax. 4 CardsMax. 4 Cards
One PRI30 or One E1 cardcounts as “2-cards”
One PRI30 or One E1 cardcounts as “2-cards”
OPB3, CTI-LinkOPB3, CTI-Link Max. 4 CardsMax. 4 Cards Max. 2 CardsMax. 2 Cards
Op
tioO
ptio
nnT
run
k T
run
k C
ardC
ardE
xtensio
n
Exten
sion
C
ardC
ard
Max. 10 CardsMax. 10 Cards Max. 5 CardsMax. 5 CardsFree Slot TOTALFree Slot TOTALFree Slot TOTALFree Slot TOTAL
Max. 11 CardsMax. 11 Cards Max. 6 CardsMax. 6 CardsSystem TOTALSystem TOTAL
Free SlotLimitation
SystemLimitation
PRI30 / E1 PRI30 / E1 count ascount as “1-card” “1-card”(Not 2) (Not 2)
PRI30 / E1 PRI30 / E1 count ascount as “1-card” “1-card”(Not 2) (Not 2)
TDA System ConfigurationTDA System Configuration - OPB3 Cards
DOOR4DOOR4DOOR2DOOR2MSG4MSG4
DOOR4DOOR4DOOR2DOOR2MSG4MSG4
ECHOECHOECHOECHO
TDA200TDA200TDA200TDA200 TDA100TDA100TDA100TDA100
Max. 4 CardsMax. 4 CardsMax. 4 CardsMax. 4 Cards Max. 2 CardsMax. 2 CardsMax. 2 CardsMax. 2 Cards
Max. 2 CardsMax. 2 CardsMax. 2 CardsMax. 2 Cards Max. 1 CardsMax. 1 CardsMax. 1 CardsMax. 1 Cards
Op
tion
Op
tion
ss
TDA System ConfigurationTDA System Configuration - Power Factor
Power Supply
Terminals and Cards
64646464
128128128128
512512512512
T7600 / T7565 / T7560 (New DPT)T7600 / T7565 / T7560 (New DPT)
T7400 / T7200 (Old DPT)T7400 / T7200 (Old DPT)
APT (T73xx) / DSS (T73/74xx)APT (T73xx) / DSS (T73/74xx)
T7600 / T7565 / T7560 (New DPT)T7600 / T7565 / T7560 (New DPT)
T7400 / T7200 (Old DPT)T7400 / T7200 (Old DPT)
APT (T73xx) / DSS (T73/74xx)APT (T73xx) / DSS (T73/74xx)
SLC8 cardSLC8 card
SLC16 cardSLC16 card
MSLC16 cardMSLC16 card
DHLC8 cardDHLC8 card
SLC8 cardSLC8 card
SLC16 cardSLC16 card
MSLC16 cardMSLC16 card
DHLC8 cardDHLC8 card
SL
TS
LT
SL
TS
LT
PT
PT
PT
PT
PWS-SPWS-SPWS-SPWS-S
PWS-MPWS-MPWS-MPWS-M
PWS-LPWS-LPWS-LPWS-L
DECT CS (TDA0142)DECT CS (TDA0142)DECT CS (TDA0142)DECT CS (TDA0142)
ISDN-Extension (2ch)ISDN-Extension (2ch)ISDN-Extension (2ch)ISDN-Extension (2ch)
KX-TVP Port (2ch)KX-TVP Port (2ch)KX-TVP Port (2ch)KX-TVP Port (2ch)
1111
4444
8888
16161616
4444
2222
1111
8888
4444
16161616
Power FactorPower FactorPower FactorPower Factor
For TDA100For TDA100For TDA100For TDA100
For TDA100/200For TDA100/200For TDA100/200For TDA100/200
For TDA200For TDA200 For TDA200For TDA200
Power Factor
TDA System ConfigurationTDA System Configuration - Calculation-1
30303030T76xxT76xxT76xxT76xx
60606060SLTSLTSLTSLT
15151515ISDN BRIISDN BRIISDN BRIISDN BRI
4444Analogue COAnalogue COAnalogue COAnalogue CO
DLC16 x 2-cards = 32 portDLC16 x 2-cards = 32 portDLC16 x 2-cards = 32 portDLC16 x 2-cards = 32 port
BRI8 x 2-cards = 16 portBRI8 x 2-cards = 16 portBRI8 x 2-cards = 16 portBRI8 x 2-cards = 16 port
SLC16 x 4-cards = 64 portSLC16 x 4-cards = 64 portSLC16 x 4-cards = 64 portSLC16 x 4-cards = 64 port
Total 9 Slots9 Slots
44
22
22
11
StepStep 11StepStep 11 RequirementRequirement Step 2Step 2Step 2Step 2 Slot CalculationSlot Calculation
Ext
en
sio
nE
xte
nsi
on
Ext
en
sio
nE
xte
nsi
on
Tru
nk
Tru
nk
Tru
nk
Tru
nk
Physical SlotsPhysical SlotsPhysical SlotsPhysical Slots
Step 3Step 3Step 3Step 3 Unit SelectionUnit Selection
TDA200TDA200 is Required
for this Configuration.Step 4Step 4Step 4Step 4 Power Factor CalculationPower Factor Calculation
SLC16 cardSLC16 cardSLC16 cardSLC16 card
SL
TS
LT
SL
TS
LT
T76xx / T7565 / T7560T76xx / T7565 / T7560T76xx / T7565 / T7560T76xx / T7565 / T7560
PT
PT
PT
PT 1111
16161616
30 30 30 30 30 30 30 30
4 4 4 4 64 64 64 64
xxxx
xxxx
====
====
Total Power Factor94949494
Therefore, is Required !PWS-MPWS-M
Power Power FactorFactorPower Power FactorFactor
LCOT8 x 1-card = 8 portLCOT8 x 1-card = 8 portLCOT8 x 1-card = 8 portLCOT8 x 1-card = 8 port
TDA System ConfigurationTDA System Configuration - Calculation-2
4444T76xxT76xxT76xxT76xx
10101010T74xxT74xxT74xxT74xx
15151515SLTSLTSLTSLT
7777ISDN BRIISDN BRIISDN BRIISDN BRI
3333ISDN ExtensionISDN ExtensionISDN ExtensionISDN Extension
Total DPT ports = 4 + 10 = 14Total DPT ports = 4 + 10 = 14
DLC16 x 1-card = 16 portDLC16 x 1-card = 16 port
Total DPT ports = 4 + 10 = 14Total DPT ports = 4 + 10 = 14
DLC16 x 1-card = 16 portDLC16 x 1-card = 16 port
6666DECT CSDECT CSDECT CSDECT CS
Total BRI ports = 7 + 3 = 10Total BRI ports = 7 + 3 = 10
BRI 8 x 2-cards = 16 portBRI 8 x 2-cards = 16 port
Total BRI ports = 7 + 3 = 10Total BRI ports = 7 + 3 = 10
BRI 8 x 2-cards = 16 portBRI 8 x 2-cards = 16 port
SLC16 x 1-card = 16 portSLC16 x 1-card = 16 portSLC16 x 1-card = 16 portSLC16 x 1-card = 16 port
CSINF8 x 1-card = 8 portCSINF8 x 1-card = 8 portCSINF8 x 1-card = 8 portCSINF8 x 1-card = 8 port
Total 5 Slots5 Slots
11
11
11
22
Step 1Step 1Step 1Step 1 RequirementRequirement Step 2Step 2Step 2Step 2 SlotSlot CalculationCalculation
Ext
en
sio
nE
xte
nsi
on
Ext
en
sio
nE
xte
nsi
on
Tru
nk
Tru
nk
Tru
nk
Tru
nk
Physical SlotsPhysical SlotsPhysical SlotsPhysical Slots
Step 3Step 3Step 3Step 3 Unit SelectionUnit Selection
TDA100TDA100 is OK
for this Configuration.
Step 4Step 4Step 4Step 4 Power Factor CalculationPower Factor Calculation
SLC8 cardSLC8 card
SLC16 cardSLC16 card
SLC8 cardSLC8 card
SLC16 cardSLC16 cardSL
TS
LT
SL
TS
LT
T76xx / T7565 / T7560T76xx / T7565 / T7560T74xx / T72xxT74xx / T72xxT76xx / T7565 / T7560T76xx / T7565 / T7560T74xx / T72xxT74xx / T72xxP
TP
TP
TP
T
DECT CS (TDA0142)DECT CS (TDA0142)DECT CS (TDA0142)DECT CS (TDA0142)
ISDN-Extension (2ch)ISDN-Extension (2ch)ISDN-Extension (2ch)ISDN-Extension (2ch) 2222
4444
1111
4444
8888
16161616
4 4 4 4 4 4 4 4
10 10 10 10 40 40 40 40
0 0 0 0 0 0 0 0
1 1 1 1 16 16 16 16 6 6 6 6 24 24 24 24
3 3 3 3 6 6 6 6
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
====
====
====
====
====
====
Total Power Factor90909090
Therefore, is Required !PWS-MPWS-M
Power Power FactorFactorPower Power FactorFactor
TDA System ConfigurationTDA System Configuration - Calculation-3
25252525T76xxT76xxT76xxT76xx
15151515SLTSLTSLTSLT
14141414ISDN BRIISDN BRIISDN BRIISDN BRI
DLC16 x 2-cards = 32 portDLC16 x 2-cards = 32 portDLC16 x 2-cards = 32 portDLC16 x 2-cards = 32 port
5555DECT CSDECT CSDECT CSDECT CS
BRI8 x 2-cards = 16 port BRI8 x 2-cards = 16 port BRI8 x 2-cards = 16 port BRI8 x 2-cards = 16 port
SLC16 x 1-card = 16 portSLC16 x 1-card = 16 portSLC16 x 1-card = 16 portSLC16 x 1-card = 16 port
CSINF8 x 1-card = 8 portCSINF8 x 1-card = 8 portCSINF8 x 1-card = 8 portCSINF8 x 1-card = 8 port
Total 6 Slots6 Slots
11
22
11
22
Step 1Step 1Step 1Step 1 RequirementRequirement Step 2Step 2Step 2Step 2 Slot CalculationSlot Calculation
Ext
en
sio
nE
xte
nsi
on
Ext
en
sio
nE
xte
nsi
on
Tru
nk
Tru
nk
Tru
nk
Tru
nk
Physical SlotsPhysical SlotsPhysical SlotsPhysical Slots
Step 3Step 3Step 3Step 3 Unit SelectionUnit Selection
Step 4Step 4Step 4Step 4 Power Factor CalculationPower Factor Calculation
SLC16 cardSLC16 cardSLC16 cardSLC16 cardSL
TS
LT
SL
TS
LT
T76xx / T7565 / T7560T76xx / T7565 / T7560T76xx / T7565 / T7560T76xx / T7565 / T7560PT
PT
PT
PT
DECT CS (TDA0142)DECT CS (TDA0142)DECT CS (TDA0142)DECT CS (TDA0142) 4444
1111
16161616
25 25 25 25 25 25 25 25
1 1 1 1 16 16 16 16
5 5 5 5 20 20 20 20
xxxx
xxxx
xxxx
====
====
====
Total Power Factor61616161
Therefore, is Required !PWS-MPWS-M
Power Power FactorFactorPower Power FactorFactor
TDA200TDA200 is Necessary !
TDA System ConfigurationTDA System Configuration - Calculation- 4
4444T76xxT76xxT76xxT76xx
10101010T74xxT74xxT74xxT74xx
15151515SLTSLTSLTSLT
7777ISDN BRIISDN BRIISDN BRIISDN BRI
3333ISDN ExtensionISDN ExtensionISDN ExtensionISDN Extension
Total DPT ports = 4 + 10 = 14Total DPT ports = 4 + 10 = 14DLC16 x 1-card = 16 portDLC16 x 1-card = 16 portTotal DPT ports = 4 + 10 = 14Total DPT ports = 4 + 10 = 14DLC16 x 1-card = 16 portDLC16 x 1-card = 16 port
6666DECT CSDECT CSDECT CSDECT CS
Total BRI ports = 7 + 3 = 10Total BRI ports = 7 + 3 = 10BRI8 x 2-cards = 16 portBRI8 x 2-cards = 16 portTotal BRI ports = 7 + 3 = 10Total BRI ports = 7 + 3 = 10BRI8 x 2-cards = 16 portBRI8 x 2-cards = 16 port
SLC16 x 1-card = 16 portSLC16 x 1-card = 16 portSLC16 x 1-card = 16 portSLC16 x 1-card = 16 port
CSINF8 x 1-card = 8 portCSINF8 x 1-card = 8 portCSINF8 x 1-card = 8 portCSINF8 x 1-card = 8 port
Total 5-Slots5-Slots
11
11
11
22
Step 1Step 1Step 1Step 1 RequirementRequirement Step 2Step 2Step 2Step 2 Slot CalculationSlot Calculation
Ext
en
sio
nE
xte
nsi
on
Ext
en
sio
nE
xte
nsi
on
Tru
nk
Tru
nk
Tru
nk
Tru
nk
Ext
en
sio
nE
xte
nsi
on
Ext
en
sio
nE
xte
nsi
on
Tru
nk
Tru
nk
Tru
nk
Tru
nk
Step 4Step 4Step 4Step 4 Power Factor CalculationPower Factor Calculation
T76xx / T7565 / T7560T76xx / T7565 / T7560T74xx / T72xxT74xx / T72xxAPT / T73/74xx DSSAPT / T73/74xx DSS
T76xx / T7565 / T7560T76xx / T7565 / T7560T74xx / T72xxT74xx / T72xxAPT / T73/74xx DSSAPT / T73/74xx DSS
SLC8 cardSLC8 card
SLC16 cardSLC16 card
MSLC16 cardMSLC16 card
DHLC8 cardDHLC8 card
SLC8 cardSLC8 card
SLC16 cardSLC16 card
MSLC16 cardMSLC16 card
DHLC8 cardDHLC8 card
SL
TS
LT
SL
TS
LT
PT
PT
PT
PT
DECT CS (TDA0142)DECT CS (TDA0142)DECT CS (TDA0142)DECT CS (TDA0142)
ISDN-Extension (2ch)ISDN-Extension (2ch)ISDN-Extension (2ch)ISDN-Extension (2ch)
KX-TVP Port (2ch)KX-TVP Port (2ch)KX-TVP Port (2ch)KX-TVP Port (2ch)
2222
1111
4444
1111
4444
4444
8888
16161616
16161616
16161616
4 4 4 4 4 4 4 4
10 10 10 10 40 40 40 40 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0
1 1 1 1 16 16 16 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 6 6 6 24 24 24 24
3 3 3 3 6 6 6 6
0 0 0 0 0 0 0 0
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
====
====
====
====
====
====
====
====
====
====
Total 90909090
Physical SlotsPhysical SlotsPhysical SlotsPhysical SlotsStep 3Step 3Step 3Step 3 Unit SelectionUnit Selection
TDA100TDA100 is OK
for this configuration.
Therefore, is Required !PWS-MPWS-M
Power Factor
TDA System ConfigurationTDA System Configuration - Calculation- 5
15151515T76xxT76xxT76xxT76xx
10101010T7330T7330T7330T7330
3333T7640T7640T7640T7640
1111PRIPRIPRIPRI
8888ISDN ExtensionISDN ExtensionISDN ExtensionISDN Extension
Total DPT ports = 15 + 3 = 18Total DPT ports = 15 + 3 = 18
DLC16 x 1-card = 16 portDLC16 x 1-card = 16 port
DHLC8 x 2-cards = 16 portDHLC8 x 2-cards = 16 port
SLC16 x 3-cards = 48 portSLC16 x 3-cards = 48 port
Total DPT ports = 15 + 3 = 18Total DPT ports = 15 + 3 = 18
DLC16 x 1-card = 16 portDLC16 x 1-card = 16 port
DHLC8 x 2-cards = 16 portDHLC8 x 2-cards = 16 port
SLC16 x 3-cards = 48 portSLC16 x 3-cards = 48 port
PRI30 x 1-card = 30 portPRI30 x 1-card = 30 portPRI30 x 1-card = 30 portPRI30 x 1-card = 30 port
Total 8-Slots8-Slots
22
11
33
11
Step 1Step 1Step 1Step 1 RequirementRequirement Step 2Step 2Step 2Step 2 Slot CalculationSlot Calculation
Ext
en
sio
nE
xte
nsi
on
Ext
en
sio
nE
xte
nsi
on
Tru
nk
Tru
nk
Tru
nk
Tru
nk
Ext
en
sio
nE
xte
nsi
on
Ext
en
sio
nE
xte
nsi
on
Tru
nk
Tru
nk
Tru
nk
Tru
nk
Step 4Step 4Step 4Step 4 Power Factor CalculationPower Factor Calculation
T76xx / T7565 / T7560T76xx / T7565 / T7560T74xx / T72xxT74xx / T72xxAPT / T73/74xx DSSAPT / T73/74xx DSS
T76xx / T7565 / T7560T76xx / T7565 / T7560T74xx / T72xxT74xx / T72xxAPT / T73/74xx DSSAPT / T73/74xx DSS
SLC8 cardSLC8 card
SLC16 cardSLC16 card
MSLC16 cardMSLC16 card
DHLC8 cardDHLC8 card
SLC8 cardSLC8 card
SLC16 cardSLC16 card
MSLC16 cardMSLC16 card
DHLC8 cardDHLC8 card
SL
TS
LT
SL
TS
LT
PT
PT
PT
PT
DECT CS (TDA0142)DECT CS (TDA0142)DECT CS (TDA0142)DECT CS (TDA0142)
ISDN-Extension (2ch)ISDN-Extension (2ch)ISDN-Extension (2ch)ISDN-Extension (2ch)
KX-TVP Port (2ch)KX-TVP Port (2ch)KX-TVP Port (2ch)KX-TVP Port (2ch)
2222
1111
4444
1111
4444
4444
8888
16161616
16161616
16161616
15 15 15 15 15 15 15 15
0 0 0 0 00 00
13131313 52 52 52 52
0 0 0 0 0 0 0 0
3 3 3 3 48 48 48 48 0 0 0 0 0 0 0 0 2 2 2 2 32 32 32 32
0 0 0 0 00 00
88 88 16 16 16 16
0 0 0 0 0 0 0 0
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
====
====
====
====
====
====
====
====
====
====
Total 163163163163
Physical SlotsPhysical SlotsPhysical SlotsPhysical SlotsStep 3Step 3Step 3Step 3 Unit SelectionUnit Selection
TDA200TDA200 is Required
Therefore, is Required !PWS-LPWS-L
51515151SLTSLTSLTSLT
BRI8 x 1-card = 8 portBRI8 x 1-card = 8 portBRI8 x 1-card = 8 portBRI8 x 1-card = 8 port 11
Power Factor
KX-TDA100/200 HardwareKX-TDA100/200 Hardware
Card Name Function Card Configuration
(Main Central Processing Unit )
MPR
(Remote Maintenance Trunk)
RMT
(Memory Expansion)
MEX
SD
(Secure Digital Card)
FLASH: 512KB SDRAM: 8MB SRAM: 1.0MB * (TDA100 0.5MB) Slide SW ( Initialise / Normal) TSW is in both MPR and LPR.
CPU : SH7709A (133MHz/32bit)
Analogue modem card Modem IC (V.90 support)
Reserved for feature expansionFlash: 8MBSDRAM: 8MBSRAM: 1MB (Version 1.1)
Pre-installed software
System will not initialise if an
SD card is not installed
-System data Back-up
Memory size: 16MB
KX-TDA0196
KX-TDA0105
(Built-in )
(This card is unnecessary
when ISDN remote is used)
MAX:33.6Kbps
KX-TDA200/100KX-TDA200/100
Main Processor Card [MPR]
Pager 1
Pager 2
LED1
(BATT Alarm)
LED2
(SD Access)
Reset Switch
System Initialize Switch
USB Port
MOH2
MOH1
*ASIC : Application Specific Integrated circuit
(Includes TSW)
SD Card Controller
Flash ROM
SRAM
USB Controller
ASIC*
SDRAM
CPU
Card Name Function Card Configuration
DHLC8
DLC16 (DLC8)
MSLC16
CSIF8
SLC16 (SLC8)
8 DPT/ APT/SLT/DSS Console ports2 power fail ports 8 DTMF receiversLevel control per port*Software downloadable from PBX
( Digital Hybrid Line)
CPU : SH-1(12.288MHz)Flash : 512KB ExternalRAM : 1KB Internal 128KB External
16(8) port DPT card DSS console can be connectedLevel control per port*Software downloadable from PBX
(Digital Proprietary Line)
CPU : SH-1(12.288MHz)Flash : 512KB ExternalRAM : 1KB Internal 128KB External
Message Waiting Lamp control16 DTMF receivers4 power fail ports Level control per port
(SLT 90VMW Lamp 48V cct.)
NO CPU
(8-port SLT Line 48V)16(8) DTMF receivers4(2) power fail ports Level control per port
(8-port Cell Station I/F )
For DECT(4ch) / 2.4GHzSS-FH(3ch)*Software downloadable from PBXLevel control per port(CSIF8 is counted as 2 EXT. cards with standard power unit.)
CPU : SH-1(12.288MHz)Flash : 512KB ExternalRAM : 1KB Internal 128KB External
Max use
TDA200 8
TDA100 4
TDA200 8
TDA100 4
TDA200 8
TDA100 4
TDA200 8
TDA100 4
TDA200 4
TDA100 2
KX-TDA0170
KX-TDA0172 (0171)
KX-TDA0175
KX-TDA0174 (0173)
KX-TDA0144
NO CPU
KX-TDA200/100KX-TDA200/100
CSIF8 Card
LED1
(Card status)
RJ45
Echo Canceling
ASIC
(MPR-LPR communication)
CPU
Flash ROM
Trans for the transmission
ASIC
(CS-LPR communication)
Card Name Function Card Configuration
LCOT16 (LCOT8)
CID/PAY8
CID8
E1
E&M 8
(Loop Start Trunk)
(Caller ID/Pay Tone)
(Caller ID ) NO CPU
Max use
TDA200 8
TDA100 4
TDA200 16
TDA100 8
TDA200 16
TDA100 8
TDA200 8
TDA100 4
TDA200 4
TDA100 2
NO CPU
NO CPU
Polarity reversal detection4 (2) power fail ports Level control per port (-6dB ~ +3dB per 3dB)
CO Caller ID type -> Bell/ETSI/DTMF type
CO Caller ID type -> Bell/ETSI/DTMF type
1-daughter board on LCOT8
2-daughter board on LCOT16
Type5DTMF/Pulse DialSignaling Type: Continuous E&M / Pulsed E&M*Software downloadable from PBX
CPU: SH-1 (12.288MHz) FLASH: 512KB RAM: Internal 1KBSRAM: 128KB
(E&M TIE line card)
RJ45/BNC (Slide SW) (ITU-T / ANSI )Connector:RJ45 (EIA/TIA)CPU : SH-1(12.288MHz) FLASH : 512KB SRAM : 512KBDSP mounted
Level control (-9dB ~ 0dB per 3 dB)*Software downloadable from PBX MFC-R2 / DTMF / Pulse DialSignaling Type: Digital R2 / Continuous E&M / Pulsed E&M
KX-TDA0181 (0180)
KX-TDA0189
KX-TDA0193
KX-TDA0188
KX-TDA0184
KX-TDA200/100KX-TDA200/100
(30ch E1 TIE line card)
Card Name Function Card Configuration
BRI8 (BRI4)
BRI2 DHLC4
LCOT4DHLC4
PRI30
Max use
TDA200 8
TDA100 4
TDA200 4
TDA100 2
TDA200 4
TDA100 2
TDA200 4
TDA100 2
(ISDN Primary)
(ISDN Basic)CPU : SH-1(12.288MHz) FLASH : 512KB SRAM : 512KBRJ45
Extension / CO trunk per port*Software downloadable form PBXLevel control (-9dB ~ 0 dB per 3 dB)Euro-ISDN / ETS
CPU : SH-1(12.288MHz) FLASH : 512KB SRAM : 512KB
Coaxial/RJ45 (Slide SW)
CO Trunk / Extension*Software Downloadable from PBXLevel control (-9 dB ~ 0 dB per 3 dB)Impedance: selective (75/120ohms)Euro-ISDN / ETS / NT1
(Ver. 1.1)
(Ver. 1.1)
2-port ISDN basic I/F for Extension / CO trunk per portDPT / APT / SLT / DSS / Console card with 4-port.
CPU : SH-1(12.288MHz) Flash : 512KB External RAM : 1KB Internal 128KB External RJ45(CO trunk side)
4-port analog LCOT (polarity reversal) 1 power fail port 4-Ports DPT / APT / SLT / DSS / Console
CPU : SH-1(12.288MHz) Flash : 512KB External RAM : 1KB Internal 128KB External RJ45 (CO trunk side)
CO Caller ID type -> Bell/ETSI/DTMF type
NO CPU TDA200 4
TDA100 2
CID4 (Ver. 1.1)
KX-TDA????
KX-TDA0288 (0284)
KX-TDA0290
KX-TDA????
KX-TDA????
(Q-SIG)
(Q-SIG)
(Q-SIG)
KX-TDA200/100KX-TDA200/100
Card Name Function Card Configuration
IP-GW4
Max use
TDA200 4
TDA100 2
Supports VoIP H.323 V.2Voice coded: G.729a, G723.1FAX:G3 64 Kbps ,Physical I/F: 10 BASE-T
(occupies 2 slots)
KX-TDA0480
(Q-SIG)
Card Name Function Card ConfigurationMax use
TDA200 1
TDA100 1 CTI-LINK CPU SH7709A(133MHZ)
FLASH:512KBSDRAM:8MB
Ethernet card for CTI communicationData controlledPhysical I/F: 10BASE-T
KX-TDA0410
(LAN I/F)
KX-TDA200/100KX-TDA200/100
DSP
(Communication between Lower card and Upper card)
CPU
SD RAM
RS232C Maintenance Port
10 Base T Ethernet Port
Upper Card ( VoIP/H.323 control )
Lower Card ( Communication with MPR )
IP-GW4 Card
FPGA*
*FPGA: Field Programmable Gate Array
LED1
(Card status)
LED2
(Link status)
RJ45
Flash Memory
Trans
LAN Controller
SD RAM
ASIC
(MPR-LPR communication)
CPU
CTI-LINK Card
Card Name Function Card Configuration
OPB3
DPH4
EIO4
MSG4
Max use
TDA200 4
TDA100 2
TDA200 4
TDA100 2
(Ver. 1.1) TDA200 4
TDA100 2
ECHO16
DPH2 (-G)
Max 3 option cards *Software Downloadable from PBX(Optional base card)
CPU : SH1(12.288MHz)ROM : 512KB(External)RAM : 1KB(internal) 128KB(External)
NO CPU
Total 16 min. Max. 64 messagesfor System
TDA200 4
TDA100 2
TDA200 8
TDA100 4
TDA200 4
TDA100 2
OGM for DISA / Queuing / Wake up Calls /
Internal hold melodyDTMF detection, CO-CO conversation DTMF repeater functions
(4-channels)
4-port Door-phone & Door-opener cardDoor-phone (T30865)
2-port Door-phone & Door-opener cardFor Germany D-phone I/F
(External I/O)4 Outputs (Relay) 4 InputsUsed for external relay / sensor
NO CPU
NO CPU
NO CPU
NO CPU
16-port Echo Cancelling card
KX-TDA0191
KX-TDA0190
KX-TDA0161
KX-TDA0162
KX-TDA0164
KX-TDA0166
KX-TDA200/100KX-TDA200/100
Not in AL version
CPU
Flash Memory
SRAM
Extended I/O
Extended I/O
DSP
Flash Memory
(rear)
Extended I/O
(rear)
DPH2
DPH4
MSG4
ASIC
OPB-3 Card
T7636 T7633 T7630 T7625
4-Position Tilt
Digital TelephonesDigital Telephones
T7640
AccessoriesAccessories
T7603T7601
T7636T7636
• 6-line x 24-character display• Backlight• 24 Programmable keys• Dual-colour LEDs• Navigator Key• Full duplex handsfree• DXDP (version 1.1)• Headset Jack• 20-character extension ID• Optional USB port• Optional 12-CO keys
DXDPDXDP (Available Ver 1.1)(Available Ver 1.1)
Up to 720m* Up to 50m*
* 0.5mm cable
DPT DPT SLT
Up to 1128m*
T7633T7633
• 3-line x 24-character display• Backlight• 24 Programmable keys• Dual-colour LEDs• Navigator Key• Full duplex handsfree• DXDP (version 1.1)• Headset Jack• 20-character extension ID• Optional USB port• Optional 12-CO keys
T7630T7630
• 3-line x 24-character display• 24 Programmable keys• Dual-colour LEDs• Navigator Key• Full duplex handsfree• DXDP (version 1.1)• Headset Jack• 20-character extension ID
T7625T7625
• 24 Programmable keys• Dual-colour LEDs• Volume Key• Full duplex handsfree• DXDP (version 1.1)• Headset Jack
T7640 DSST7640 DSS
• 60 DSS/BLF keys• Fully-programmable flexible
keys• For all T76xx models• Requires 1 digital port
T7603 Add-on ModuleT7603 Add-on Module
• 12 Programmable keys• Dual-colour LEDs• Connects to DPT• No additional port required• For T7636 & T7633 only
T7590 DECT PST7590 DECT PS
• 4L x 16C Display• 3 Programmable CO keys• Tri-colour LED• Caller ID• Ringer
– 6 tone, 4 melody + vibrate
• 100 number directory
Resource TDA100 TDA200
8 8Tenant
Incoming Call Distribution Group
VM(DPT) Group
VM(DTMF) Group
Queuing Time Table
Idle Hunting Group
Absent Message
Message Waiting
No. chars of the name
Extension Digits
Call Park Area
COS
Trunk Group
Paging Group
Call Pick up Group
64 (32Extn)
2
2
64
64 (16Extn)
9
256
20
1- 4
100
64
64 32
64
64
6432
64
64 (32Extn)
2
2
64
64 (16Extn)
9
256
20
1- 4
100
SMDR(Call Information data) 200 200
System ResourcesSystem Resources
TDA100 TDA200
10x3p – 4x8p (32CNFT) 10x3p – 4x8p (32CNFT)Conference
Verified Code
Special Carrier Code
Host PBX Access Code
DDI/DID Table
10 digits, 1000 entries
16 digits, 20 entries
10 digits, 4 entries/TG
16 digits, 1000 entries
10 digits, 1000 entries
16 digits, 20 entries
10 digits, 4 entries/TG
16 digits, 1000 entries
System ResourcesSystem Resources
Resource
TDA100 TDA200
Quick Dial
System Speed Dial
Station Speed Dial
One Touch Dial
Pick up Dial
Key Pad protocol Dial
Redial
Emergency Dial
1-4 digits, 80 entries
32 digits, 1000 entries
32 digits, 10 ent./Ext
32 digits
32 digits
32 digits
32 digits
32 digits, 10 entries 32 digits, 10 entries
1-4 digits, 80 entries
32 digits, 1000 entries
32 digits, 10 ent./Ext
32 digits
32 digits
32 digits
32 digits
System ResourcesSystem Resources
Resource
TDA100 TDA200
16 16Routing Plan
TIE Routing Table
Leading Digits
PBX Code
Toll Restriction Level
Toll restriction Code
Toll restriction Exception Code
Leading Digits
Exception Leading Digits
ARS/LCR Carrier
Itemized Code
Authorization Code
32 entries
3 digits
7 digits
7
7 digits, 100 entries/LV
16 digits, 200 entries
10 digits, 1000 entries
200 entries
10
5 digits
20 digits
10 digits, 1000 entries
200 entries
10
5 digits
20 digits
32 entries
3 digits
7 digits
7
7 digits, 100 entries/LV
16 digits, 200 entries
System ResourcesSystem Resources
Resource
TDA100 TDA200
8 digits 8 digitsCharge Rate
VPS(DPT) Number of Channels
Mail BOX No.Digits
System Password (Administrator)
System Password (End user)
Manager Password
Charge Currency
Charge Record for Hotel
Call Log-Outgoing Call
Call Log-Incoming Call
VPS(DPT) No. of Systems
24 CH
16 digits
4-10 digits
4-10 digits
4-10 digits
3 chars
1000
0-100 log/EXTN
MAX. 640 log/Sys
0-100 log/EXTN
MAX. 1280 log/Sys
2 systems
3 chars
2000
2 systems
24 CH
16 digits
4-10 digits
4-10 digits
4-10 digits
0-100 log/EXTN
MAX. 640 log/Sys
0-100 log/EXTN
MAX. 1280 log/Sys
Call Log-Incoming Call - ICD Group 0-100 log/EXTN
MAX. 640 log/Sys
0-100 log/EXTN
MAX. 640 log/Sys
Extension PIN 0-10 digits/Station 0-10 digits/Station
System ResourcesSystem Resources
Resource
FeaturesFeatures
InstallationInstallation
Installation RequirementsInstallation Requirements
• Dedicated 240VAC Power Source
• Static-Preventive procedures• Category 3 Cabling (minimum Requirement)
• Avoid RF Interference (as much as possible)
• Avoid HF Interference (as much as possible)
• PC with TDA Maintenance s/w installed• SD Card Reader/Writer (highly recommended)
Main Unit InstallationMain Unit Installation
Wall Mounting
Main Unit InstallationMain Unit Installation
Floor Mounting (TDA200 only)
Minimum
Clearances
10cm to left & right
20cm above
Do not place objects on
top of the Main Unit
Main Unit InstallationMain Unit Installation
20cm
10cm 10cm
Main Unit ConstructionMain Unit Construction
Power SuppliesPower Supplies
RMT Card InstallationRMT Card Installation
MPR Card
CID/Paytone Card InstallationCID/Paytone Card Installation
ELCOT16 Card
E1 Card InstallationE1 Card Installation
Trunk or Trunk or ExtensionExtension
BRI Card InstallationBRI Card Installation
Trunk or Trunk or ExtensionExtension
PRI Card InstallationPRI Card Installation
Trunk or Trunk or ExtensionExtension
Option Card InstallationOption Card Installation
Option Card InstallationOption Card Installation
DECT InstallationDECT Installation
Refer to Handout
CSIF8 Card
Cabling
• SD Card MUST be installed.
• Begin with power ‘disconnected’, not just switched off.
• Discharge static before touching anything on the system.
See Getting Started Guide
Start-up PrecautionsStart-up Precautions
ProgrammingProgramming
ProgrammingProgramming
• Windows-based Maintenance Console
• Structured Menu system
• Multi-connection – RS232c/USB/Modem/LAN/ISDN Remote
• SD Card Backup feature
• Diagnostics
• BRI Auto-configuration
ConnectionConnection
•LAN Connection via CTI Link Card
•Modem Connection via RMT Card
•External Modem Connection
•ISDN Modem Connection
PC Programming SoftwarePC Programming Software
TroubleshootingTroubleshooting& Diagnostics& Diagnostics
• Built-in Diagnostics– Initial self-diagnostic test– Various on-line diagnostic tests
• Background• Manual• Regular
– Digital Line Error Rate monitor
Troubleshooting & DiagnosticsTroubleshooting & Diagnostics
• Self-diagnosis– Hardware is tested for each individual card
at start-up.– Error indication is shown on the card LEDs.– Errors are recorded in the system log.
Troubleshooting & DiagnosticsTroubleshooting & Diagnostics
• On-line Diagnostics– Periodical ‘active’ tests.– Hardware Interrupt monitoring– Reporting by:
• System Alarm LED• Card Status LED• Error Log• Local Alarm• Remote Alarm
Troubleshooting & DiagnosticsTroubleshooting & Diagnostics
LED1 : Battery Alarm
LED2 : SD card access
MPU Card
Troubleshooting & DiagnosticsTroubleshooting & Diagnostics
LED1OFFG ONG FlashR ONR Flash
: Power OFF: Normal (all idle): Normal (in use) : Fault / Reset: Out of Service
Option Cards
Troubleshooting & DiagnosticsTroubleshooting & Diagnostics
• Local Alarm– On-site notification– Alarm button programmed on DPT
• Remote Alarm– PC Console / PC Phone– Local Alarm creates e-mail message
Troubleshooting & DiagnosticsTroubleshooting & Diagnostics
Troubleshooting & DiagnosticsTroubleshooting & Diagnostics
Internet
System
PC Console or PC Phone
DPT
SMTP Server
Customer Site
Dealer Site
Troubleshooting & DiagnosticsTroubleshooting & Diagnostics
Thank YouThank You