![Page 1: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/1.jpg)
Pritam Mukherjee and L. Satish
HV Lab, Dept. of Electrical Engineering
Indian Institute of Science, Bangalore
HV Lab, Dept. of Electrical Engineering, IISc
![Page 2: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/2.jpg)
If the damage in the nascent stage is allowed to grow, it may develop into a catastrophic failure in future. Thus, early detection of mechanical damage condition is paramount.
HV Lab, Dept. of Electrical Engineering, IISc
![Page 3: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/3.jpg)
Terminals accessible
1. Damage-condition be identified at its infancy 2. Its location and severity should be assessable 3. Accomplish the above task non-invasively, i.e.,
using ONLY quantities that are measurable from the terminals
1. Provides prerequisite sensitivity to detect such conditions
2. A mismatch in FRA implies a damage-situation 3. But, currently is limited to detection only 4. Unique interpretation of FRA is not yet possible
HV Lab, Dept. of Electrical Engineering, IISc
![Page 4: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/4.jpg)
HV Lab, Dept. of Electrical Engineering, IISc
A mechanical damage in the winding leads to inductance & capacitance changes. This causes a new set of natural frequencies.
![Page 5: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/5.jpg)
HV Lab, Dept. of Electrical Engineering, IISc
![Page 6: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/6.jpg)
Radial Displacement Localization
HV Lab, Dept. of Electrical Engineering, IISc
![Page 7: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/7.jpg)
HV Lab, Dept. of Electrical Engineering, IISc
![Page 8: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/8.jpg)
3mm
5mm
6mm
4mm
HV Lab, Dept. of Electrical Engineering, IISc
![Page 9: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/9.jpg)
HV Lab, Dept. of Electrical Engineering, IISc
The monotonic variation of ΔΨscnf is the key to localize the change. This property is used for locating and assessing the severity of an RD An AD involves a large number of inductance changes as well as capacitance changes. So, handling AD is more involved. But, monotonicity of ΔΨscnf can be used to advantage for the task of localization
![Page 10: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/10.jpg)
HV Lab, Dept. of Electrical Engineering, IISc
Performance of the algorithm independent of the location or the extent of AD
![Page 11: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/11.jpg)
Analytical framework established for FRA diagnosis
New relationships derived to correlate winding parameters to natural frequencies
RD and AD in an actual winding can be located, its severities can also be assessed
Future scope: Existing formulation has to be extended for diagnosis of other types of damages
HV Lab, Dept. of Electrical Engineering, IISc
![Page 12: HV Lab, Dept. of Electrical Engineering Indian Institute ...divsymposium/EECS2016/slides-2016-04-25/... · Pritam Mukherjee and L. Satish HV Lab, Dept. of Electrical Engineering Indian](https://reader031.vdocuments.us/reader031/viewer/2022020411/5a835cd57f8b9ada388e7c5c/html5/thumbnails/12.jpg)
HV Lab, Dept. of Electrical Engineering, IISc