huawei concheck param rev1

10
Group CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel CelSel PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH PRACH

Upload: pakcik-kamal

Post on 28-Sep-2015

240 views

Category:

Documents


0 download

DESCRIPTION

parameter

TRANSCRIPT

Sheet1GroupTDN RulesDescriptionParameter NameDefault Value Recommended ValueRemarksCelSelThe minimum required quality threshold corresponding to CPICH Ec/NoMin quality levelQqualmin-18-18Subjected to Operators RequirementCelSelThe minimum required quality threshold corresponding to CPICH RSCPMin Rx levelQrelevmin-58-58Subjected to Operators RequirementCelSelThe maximum allowed uplink transmit power of a UE in the cell,Max allowed UE UL TX powerMaxAllowedUlTxPower2424Subjected to Operators RequirementCelSelThreshold for intra-frequency cell measurements in idle mode in SIB3Intra-freq cell reselection threshold for idle modeIdleSintrasearch55Subjected to Operators RequirementCelSelThreshold for inter-frequency cell measurements in idle mode in SIB3Inter-freq cell reselection threshold for idle modeIdleSintersearch44Subjected to Operators RequirementCelSelThreshold for inter-RAT cell measurements in SIB3 and SIB4Inter-RAT cell reselection thresholdSsearchRat22Subjected to Operators RequirementCelSelThreshold for intra-frequency cell measurements in connected mode in SIB4Intra-freq cell reselection threshold for connect modeConnSintrasearch55Subjected to Operators RequirementCelSelThreshold for inter-frequency cell measurements in connected mode in SIB4Inter-freq cell reselection threshold for connect modeConnSintersearch44Subjected to Operators RequirementCelSelMeasurement quantity of cell selection and reselectionCell Sel-reselection quality measureQualMeasCPICH_ECNO(CPICH Ec/N0)CPICH_ECNO(CPICH Ec/N0)Subjected to Operators RequirementCelSelCell reselection delay timeReselection delay timeTreselections11Subjected to Operators RequirementCelSelHysteresis value of the serving cell in idle mode when "QualMeas" is set to CPICH_RSCP(CPICH RSCP)Hysteresis 1 for idle modeIdleQhyst1s22Subjected to Operators RequirementCelSelHysteresis value of the serving cell in connected mode when "QualMeas" is set to CPICH_RSCP(CPICH RSCP)Hysteresis 1 for connect modeConnQhyst1s22Subjected to Operators RequirementCelSelHysteresis value of the serving cell in idle mode when "QualMeas" is set to CPICH_ECNO(CPICH Ec/N0)Hysteresis 2 for idle modeIdleQhyst2s11Subjected to Operators RequirementCelSelHysteresis value of the serving cell in connected mode when "QualMeas" is set to CPICH_ECNO(CPICH Ec/N0)Hysteresis 2 for connect modeConnQhyst2s11Subjected to Operators RequirementCelSelOffset of the measured CPICH RSCP used for cell reselection when the UE is in idle modeIdleQoffset1snIdleQoffset1sn00Subjected to Operators RequirementCelSelOffset of the measured CPICH Ec/No used for cell reselection when the UE is in idle modeIdleQoffset2snIdleQoffset2sn00Subjected to Operators RequirementCelSelCell offset used for CPICH RSCP measurement value in cell selection or reselection when the UE is in connected modeConnQoffset1snConnQoffset1sn00Subjected to Operators RequirementCelSelCell offset used for CPICH Ec/No measurement value in cell selection or reselection when the UE is in connected modeConnQoffset2snConnQoffset2sn00Subjected to Operators RequirementPRACHUniquely identifying a PRACH in a cellPRACH IDPhyChId44PRACHthe mapping of AC 0~9 to ASCsAC 0~9 to ASC mappingAc09ToAscASC0ASC0PRACHthe mapping of AC 10 to ASCsAC 10 to ASC mappingAc10ToAscASC0ASC0PRACHmapping of AC 11 to ASCsAC 11 to ASC mappingAc11ToAscASC0ASC0PRACHmapping of AC 12 to ASCsAC 12 to ASC mappingAc12ToAscASC0ASC0PRACHmapping of AC 13 to ASCsAC 13 to ASC mappingAc13ToAscASC0ASC0PRACHmapping of AC 14 to ASCsAC 14 to ASC mappingAc14ToAscASC0ASC0PRACHmapping of AC 15 to ASCsAC 15 to ASC mappingAc15ToAscASC0ASC0PRACHThreshold for UE sending RRC CONNECTION REQUESTTimer 300T300D2000D2000PRACHMaximum number of retransmissions of the RRC CONNECTION REQUEST messagConstant 300N30033PRACHThreshold for UE to start established a dedicated modeTimer 312T31266PRACHMaximum number of consecutive "in sync" indications received from Layer 1Constant 312N312D1D1PRACHThreshold for UE sends a CELL UPDATE/URA UPDATETimer 302T302D2000D2000PRACHMaximum number of retransmissions of the CELL UPDATE/URA UPDATE messageConstant 302N30233PRACHThreshold for UE sends a UE CAPABILITY INFORMATION messageTimer 304T304D2000D2000PRACHMaximum number of retransmissions of the UE CAPABILITY INFORMATION messageConstant 304N30433PRACHThreshold forUE enters the CELL_FACH, URA_PCH, or CELL_PCH stateTimer 305T305D30D30PRACHThreshold for UE sends a UE detects "in service area."Timer 307T307D30D30PRACHThreshold for UE sends a UE sends an RRC CONNECTION RELEASE COMPLETE messageTimer 308T308D40D40PRACHMaximum number of retransmissions of the RRC CONNECTION RELEASE COMPLETE messageConstant 308N30811PRACHThreshold for UE sends a UE receives a CELL CHANGE ORDER FROM UTRAN messageTimer 309T30955PRACHThreshold for UE sends a UE detects N312 consecutive "in sync" indications from Layer 1Timer 312T31266PRACHMaximum number of consecutive "in sync" indications received from Layer 1Constant 312N312D1D1PRACHThreshold for UE sends a UE detects N315 successive "in sync" indications form Layer 1Timer 313T31333PRACHMaximum number of successive "out of sync" indications received from Layer 1Constant 313N313D50D50PRACHThreshold for UE sends a radio link synchronization failure are fulfilled and only RBs associated with T314 existTimer 314T314D0D0PRACHThreshold for UE sends a radio link synchronization failure are fulfilled and only RBs associated with T315 existTimer 315T315D0D0PRACHMaximum number of successive "in sync" indications received from Layer 1 after T313 starts.Constant 315N315D1D1PRACHThreshold for UE sends a RNC send message "RRC CONNECTION SETUP"(or "CELL UPDATE CONFIRM")Timer 381T381D600D600PRACHThreshold for UE is in the URA_PCH or CELL_PCH state and detects "out of service area.Timer 316T316D30D30PRACHMaximum number of resend times of message "RRC CONNECTION SETUP" or "CELL UPDATE CONFIRM".Constant 381N381D1D1PRACHThreshold for If the UE checks that no PS/CS data is transmittedTimer 323T323INVALIDINVALIDPwr CtrlMax Transmit Power of CellMax Transmit Power of CellMaxTxPower430448