hpi market shimadzu’s total solutions for the hydrocarbon ... · gpa 2286, gpa 2186 uop 539, astm...
TRANSCRIPT
Analytical and Testing Instruments for the HPI Market
Shimadzu’s Total Solutionsfor the Hydrocarbon Processing Industry
Natural Gas Analyzers *
Refinery Gas Analyzer (RGA) **
Green House Gas Analyzers TOGAS Analyzer TOGAS w/ BID Analyzer Simulated Distillation DHA/PIONA Analyzers GPC Analyzer Aromatics Analyzers Oxygenates in Gasoline
AnalyzerApplication Methods ASTM D1945/D1946,
GPA 2261, GPA 2177, GPA 2286, GPA 2186
UOP 539, ASTM D7833, D3588, D1945, D1946
ASTM D3612A,B & C*** ASTM D3612A,B & C*** ASTM D2887, ASTM D3710, ASTM D5307, ASTM D6352, ASTM D6417, ASTM D7096, ASTM D7169, ASTM D7213, and ASTM D7500.
ASTM D6729, ASTM D6730 ASTM D6474, D6579, D5296 ASTM-D3606, ASTM-D5580 ASTM-D4815
Analysis Air/Nitrogen, Methane, CO2, Ethane, Propane, I-Butane, N-Butane, Neo-Pentane, I-Pentane, N-Pentane and Hexanes+ by backflush
C1-C6+ saturates and unstarurates, H2S,Non-Condfensabvle gases, O2,N2,CO & H2, LPG sampling, Vaporizer
N2O, CO2 and CH4 in atmospheric air. This system will also separate and provide quantitative information for N2, O2 and CO. *SF6 can be added per special request. The run time can be extended to include ethane, othylene and acetylene in the analysis.
Accurate measurement of dissolved gases which include H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2 in mineral spirit based transformer oil via direct injection and oil stripper extraction
O2, N2, CH4, CO are separated and detected by BID; CO2, C2H2, C2H4, C2H6 and C3H6 detected by FID. CO2 passes through a Methanizer and is reduced to CH4, which, is combustible and analyzed by FID.
C6 to C44 alkane Single-column application for the separation and identification of six main compound classes in spark ignition fuel samples: paraffins, Isoparaffins, olefins, naphthalenes, aromatics, and oxygenates.
Molecular Weuight distribution of polymers which separates molecules by size.
Using D3606, dedicated to the separation and quantification of benzene and toluene in finished gasoline. Benzene can be determined between the levels of 0.1 and 5 volume % and toluene can be determined between the levels of 2 and 20 volume %. Ethanol co-elution is managed by using a special proprietary column set.
Individual ethers are determined from 0.1 to 20.0 as %. Individual alcohols are determined from 0.1 to 12.0 mass %.
Features • Turnkey systems• Fully configured• Customizable systems• Automatic BTU reports
• Automatic Refinery Gas BTU report• 6 minute fast analysis time• Four simultaneous injections
• Includes 3 detectors and a methanizer• Low-level analysis• 15 minute fast analysis time
• Offer all three methods• High sensitivity• Extension up to C4• Choice of 2 headspace models
• TCD replaced by very sensitive BID• Hydrogen & methane sensitivity down to 100ppb• Turnkey system
• Support all official SimDist methods• Simdist software fully integrated into LabSolutions • Simple automated operation• Distillation curve overlay• Distillation reports and curve data can be easily exported as ASCII data to Excel • Results correlated to D86 or D1160
• Simple single-column method• All recommended consumables included• Room temperature method
• Stable detector• Easy-to-use GPC software• Customizeable report layout• Fully integrated HPLC system
• 10 minute fast analysis time• Complete turnkey systems
• Rugged configuration• Economical
Shimadzu Customized GC Analyzers
Shimadzu Headspace HS-20
• LPG Sampling Devices, Vaporizers• Complete application manual and methods• Customized Analyzers
GC-2010 Plus GC-2014Nexis GC-2030
* Includes Extended Natural Gas Analyzers ** Includes Fast Refinery Gas Analyzer *** Shimadzu pioneered the B&C methods
Natural Gas Analyzers *
Refi nery Gas Analyzer (RGA) **
Green House Gas Analyzers TOGAS Analyzer TOGAS w/ BID Analyzer Simulated Disti llati on DHA/PIONA Analyzers GPC Analyzer Aromati cs Analyzers Oxygenates in Gasoline
AnalyzerApplicati on Methods ASTM D1945/D1946,
GPA 2261, GPA 2177, GPA 2286, GPA 2186
UOP 539, ASTM D7833, D3588, D1945, D1946
ASTM D3612A,B & C*** ASTM D3612A,B & C*** ASTM D2887, ASTM D3710, ASTM D5307, ASTM D6352, ASTM D6417, ASTM D7096, ASTM D7169, ASTM D7213, and ASTM D7500.
ASTM D6729, ASTM D6730 ASTM D6474, D6579, D5296 ASTM-D3606, ASTM-D5580 ASTM-D4815
Analysis Air/Nitrogen, Methane, CO2, Ethane, Propane, I-Butane, N-Butane, Neo-Pentane, I-Pentane, N-Pentane and Hexanes+ by backfl ush
C1-C6+ saturates and unstarurates, H2S,Non-Condfensabvle gases, O2,N2,CO & H2, LPG sampling, Vaporizer
N2O, CO2 and CH4 in atmospheric air. This system will also separate and provide quanti tati ve informati on for N2, O2 and CO. *SF6 can be added per special request. The run ti me can be extended to include ethane, othylene and acetylene in the analysis.
Accurate measurement of dissolved gases which include H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2 in mineral spirit based transformer oil via direct injecti on and oil stripper extracti on
O2, N2, CH4, CO are separated and detected by BID; CO2, C2H2, C2H4, C2H6 and C3H6 detected by FID. CO2 passes through a Methanizer and is reduced to CH4, which, is combusti ble and analyzed by FID.
C6 to C44 alkane Single-column applicati on for the separati on and identi fi cati on of six main compound classes in spark igniti on fuel samples: paraffi ns, Isoparaffi ns, olefi ns, naphthalenes, aromati cs, and oxygenates.
Molecular Weuight distributi on of polymers which separates molecules by size.
Using D3606, dedicated to the separati on and quanti fi cati on of benzene and toluene in fi nished gasoline. Benzene can be determined between the levels of 0.1 and 5 volume % and toluene can be determined between the levels of 2 and 20 volume %. Ethanol co-eluti on is managed by using a special proprietary column set.
Individual ethers are determined from 0.1 to 20.0 as %. Individual alcohols are determined from 0.1 to 12.0 mass %.
Features • Turnkey systems• Fully confi gured• Customizable systems• Automati c BTU reports
• Automati c Refi nery Gas BTU report• 6 minute fast analysis ti me• Four simultaneous injecti ons
• Includes 3 detectors and a methanizer• Low-level analysis• 15 minute fast analysis ti me
• Off er all three methods• High sensiti vity• Extension up to C4• Choice of 2 headspace models
• TCD replaced by very sensiti ve BID• Hydrogen & methane sensiti vity down to 100ppb• Turnkey system
• Support all offi cial SimDist methods• Simdist soft ware fully integrated into LabSoluti ons • Simple automated operati on• Disti llati on curve overlay• Disti llati on reports and curve data can be easily exported as ASCII data to Excel • Results correlated to D86 or D1160
• Simple single-column method• All recommended consumables included• Room temperature method
• Stable detector• Easy-to-use GPC soft ware• Customizeable report layout• Fully integrated HPLC system
• 10 minute fast analysis ti me• Complete turnkey systems
• Rugged confi gurati on• Economical
Various Applica� ons in the Hydrocarbon Processing Industry
GC-2014 GC-2010 Plus
Shimadzu Simdist SystemShimadzu BID DetectorHigh Sensi� vityDetecti on sensiti vity over 100x higher than TCD, 2x higher than FIDNovel Universal DetectorSingle-detector approach for your complex analysesLong-Term StabilityLong-term stability with new discharge design
Nexis GC-2030
ASTM D 6591, D6379, D5186,
ASTM D5837
Custom Methods
IP 391,
Custom Methods
Custom Methods
Aromatics in fuels
Individual Furanic
Additives in polymers
Components in Transformer Oil
SwitchingValve
Configuration
FullyIntegrated
System
High Speed andHigh Sensitivity
SuperPerformance
andExpandability
NetworkConnectivity
Scan Speed30000u / sec
PreciseSample
Injection
High SensitivityDetector
MRM 555 Ch / Sec
EPA 8270B, TO-14 Custom Methods
Volatile Organic CompoundsArsine Phosphine in Ethylene
Accessories HS,TD and P&T
High Sensitivityand Reduced
Cost
High EfficientMulticomponent
Analysis
IP 436, IP 548
Aromatics AnalyzerHPLCFeatures
FeaturesFuran Analysis
HPLC
LC / MS / MS
VOC’s with GCMS
Applicable Methods
Analysis
Applicable Methods
Analysis
Applicable Methods
Analysis
Applicable Methods
Analysis
Features
Features
Customized
Trace Elements in Naphtha
All Elements
All Elements
All Elements
ICPMS-2030
ICP-9820Elemental Analysis ASTM D4951, D5184ASTM D4951,D5184 UOP 389, UOP 303UOP 714, APHA 3120, IFP 9507
ASTM D6595, D3237, D3567D3605, D3635, D3831, D3919D4628
ASTM D5839, ASTM D4294, C114ISO 8754
AA-7000
EDX-7000 / 8000
Sulfur in Oil
Lubricating oils
Lubricating oil
Petroleum Naphtha, Gasoline
Petroleum oils
Easy MethodDevelopment
Easy MethodDevelopment
LowestRunning Cost
Low ArgonConsumption
High Stability,High Sensitivity
and Low Interfernce
Easy-To-UseOperation
All WavelengthAcquisition
Unique 3DDouble Beam
Optics
ComprehensiveSafety Functions
DualBackgroundCorrectionFunctions
High Sensitivity,High Speed andHigh Resolution
Large SampleChamber
Additives in polymers
Features
Features
Applicable Methods
Analysis
Applicable Methods
Analysis
Applicable Methods
Analysis
Applicable Methods
Analysis
Features
Features
Excellent
and Reliability
A New
Fame in Biodiesel
Measuring Oil in Water
FTIR
UV-Vis
ASTM D5412
Thermal Analyzers
Spectroflurophotometer
High Stability and High Speed
High Speed3D Scanning
FluorescenceQuantum Yield
and FluorescenceQuantumEfficiency
Measurement
D7371, EN 14078
ASTM D1840, D2008
ASTM D3417, D3418, D4419,
Custom Methods
Custom Methods
D4591, D5483,
Custom Methods
ASTM D3850, D6370, D6375, Custom Methods
Petroleum Products
Thermal Proper es of Polymers
Total Petroleum Hydrocarbons
Turbine Fuels
DSC, TGA, TG/DTA, TMA
Addi ves in Polymers
Mineral Oils
Broad range ofProducts
HighPerformance
DSC / TGA
High Resolu on
DiverseMeasurements
by SimpleOpera ons
Easy Opera on
High Sensi vity
Features
Features
Applicable Methods
Analysis
Applicable Methods
Analysis
Applicable Methods
Analysis
Applicable Methods
Analysis
Features
Features
ASTM D7573, EN 1484, EPA 415.1APHA 5310B
TOC in Various Types of Water
TOC in Various Types of Water
TOC
Online TOC
High Salt Kit
SuperiorSampling
Units
ISO 6892, ISO 527, ASTM D638
Custom Methods
Tensile Proper es of Metals
High Salt Content Water
Tensile Proper es of Plas cs
680 DegCCombus on
Method
Short TestCycle Time
Low
Cost
Ultrafast Sampling Rate
StandaloneSystem
LowMaintenance
Cost
Eight FoldHigh Resolu on
Testing Machines
Features
Features
Applicable Methods
Analysis
Applicable Methods
Analysis
Applicable Methods
Analysis
Applicable Methods
Analysis
Features
Features
Gel Permea�on ChromatographyASTM D6474, D6579, D5296
Gel Permea�on ChromatographyStable
Detec�on
Ease of Use GPC So�ware
Fully Integrated
HPLC
O
▶
Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation and its affiliates, whether or not they are used with trademark symbol “TM” or “ R “.Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
For Research Use Only. Not for use in diagnostic procedures.The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.
Shimadzu CorporationURL: www.shimadzu.com/an/
Shimadzu Scientific Instruments7102 Riverwood Drive, Columbia, Maryland 21046, U.S.A.Phone: 800-477-1227/410-381-1227, Fax: 410-381-1222URL: www.ssi.shimadzu.com
Total Solutions for the Hydrocarbon Industry
North American HQ Solution Center
Integrated Technology Center Networking Center
Classroom Training