hpe 12500 switch series data sheet · performance with a feature-rich tcam-based acl implementation...
TRANSCRIPT
-
Key features
•Optimizedfordatacenterswithextensivevirtualizationandconvergencefeatures
•Broadinterfaceoptionsfrom1Gto100Gscalingupto24.3Tb/sswitchingcapacity
•SDNreadywithOpenFlow1.3support
•LargeLayer2andLayer3tablestosupportlargescaledeployments
•Fullyredundantarchitecturewithhotswappablecomponents
Product overview
TheHPE12500SwitchSeriesisafamilyofpowerful,next-generationroutingswitcheswithoutstandingcapacityandscaleforthenetworkcoreordatacenter.
Designedforhighperformancewithnon-blockinganddistributedClosarchitecture,theseswitchesdeliverupto24.3Tb/sswitchingcapacityand10.8Bppsthroughputwithupto400Gb/sperlinecardslot.
The12500switchesalsohaveenergy-efficiencyfeaturesthatdrivedownoperationalexpensesandareidealfororganizationscontemplatinglarge-scaledatacenterconsolidations,businesscontinuityanddisasterrecoverysites,metropolitanareanetworkdeployments,andotherapplicationsrequiringarobust,reliable,andhighlyavailableswitchingplatform.
HPE 12500 Switch Series
Data sheet
-
Page 2Data sheet
Features and benefits
Data center optimized•ScalableLayer2fabrics
Buildflexible,resilient,andscalableLayer2fabricswithSPBandHPEIRF
•Multi-tenantDeviceContext(MDC)
Isaninnovativedatacentervirtualizationsolutionthatenablesmulti-tenancy,givingcustomerstheabilitytovirtualizeaphysicalswitchintomultiplelogicaldevices,witheachlogicalswitchhavingitsowntenants
•HPEEthernetVirtualInterconnect(EVI)
IsanHPEVirtualApplicationNetworkinnovationthatprovidesaLayer2extensionacrossthedatacentertosimplifytheinterconnectivityofgeographicallydispersedatacenters
•DataCenterBridging(DCB)protocols
ProvidesupportforIEEE802.1QazDataCenterBridgingExchange(DCBX),EnhancedTransmissionSelection(ETS),andIEEE802.1QbbPriorityFlowControl(PFC)forconvergedfabrics
•FibreChanneloverEthernet(FCoE)features
DeliversupportforFCoE,includingexpansion,fabric,trunkVFandNports,andaggregationofE-portandN-portvirtualization
•Acceleratedperformancewithjumboframes
Forintra-data-centercommunication,orfordatacentertodatacentertraffic(disasterrecovery),reducingtheamountoftimerequiredfordatabackupandrecovery
•Networkloadbalancing(NLB)multicastARP
Microsoft®NLBco-workswithmulticastARPtoprovideserverswithloadbalancingandfaultswitchover,whichlowerscostsandinvestment
-
Page 3Data sheet
Software-defined networking•SupportsOpenFlow1.3specifications
ToenableSDNbyallowingseparationofthedata(packetforwarding)andcontrol(routingdecision)paths
Performance•High-performancedesignwithnon-blockinganddistributedClosarchitecture
Deliversupto24.3Tb/sswitchingcapacityand10.8Bppsthroughputwithupto400Gb/sperlinecardslot
•High-density1/10/40/100GbEinterfaceconnectivity
Offersupto18interfacemoduleslotstoscaleupto8641GbEor1/10GbEor28840GbEor72100GbEports
•Hardware-basedwirespeedaccesscontrollists(ACLs)
Helpprovidehighlevelsofsecurityandeaseofadministrationwithoutimpactingnetworkperformancewithafeature-richTCAM-basedACLimplementation
•High-performanceprocessorsystem
Thesupervisormoduleusesthreedifferentprocessorstoisolatekeytasks:controlplane(STP,OSPF,BGP,MPLS,etc.),fastrecoveryprotocols(RRPP,BFD,etc.),andchassismanagement(temperature,power,etc.)
Product architecture•Distributedarchitecturewithseparationofdataandcontrolplanes
Deliversenhancedfaulttoleranceandfacilitatescontinuousoperationandzeroservicedisruptionduringplannedorunplannedcontrol-planeevents
•AdvancedComwaremodularOS
Bringsmodularity,enhancedserviceability,stability,andindependentprocessmonitoringthroughmodernComwarev7OperatingSystem
•In-ServiceSoftwareUpgrade(ISSU)
Providesanupgradeoftheentirechassis,oranindividualtaskorprocess,withzeropacketloss
-
Page 4Data sheet
Resiliency and high availability•IntelligentResilientFramework(IRF)
Createsvirtualresilientswitchingfabrics,wheretwoormoreswitchesperformasasingleL2switchandL3router;switchesdonothavetobeco-locatedandcanbepartofadisaster-recoverysystem;serversorswitchescanbeattachedusingstandardLACPforautomaticloadbalancingandhighavailability;caneliminatetheneedforcomplexprotocolslikeSpanningTreeProtocol(STP),Equal-CostMultipath(ECMP),orVRRP,therebysimplifyingnetworkoperation
•Ultrafastprotocolconvergence
EnableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforRIP,OSPF,BGP,IS-IS,VRRP,MPLS,andIRF
•DeviceLinkDetectionProtocol(DLDP)
Monitorslinkconnectivityandshutsdownportsatbothendsifunidirectionaltrafficisdetected,preventingloopsinSTP-basednetworks
•Completesetofroutingprotocols(Layer3IPv4andIPv6)
SupportingwiderangeofroutingprotocolsincludingRIP,OSPF,IS-IS,andBGPforbothIPv4andIPv6alongwithcompletesupportofPIM-DM,PIM-SM,PIM-SSM,andMSDP
•Hotpatching
The12500SwitchSeriessupportshotpatching,allowingin-servicepatchingforsomeisolatedsoftwareproblems
•NonstopForwarding/GracefulRestart(NSF/GR)
Usingstandardized-basedIETFprotocols,the12500SwitchSeriesprovidesnonstopforwarding(switching/routing)forLayer3routingprotocols(controlplane—OSPF,BGP,andMPLS),providinghitlessfailover
•Fullyredundantandhotswappablecomponents
Providingfullhardwareredundancyforeachcomponentincludingpowersupplies,fantrays,supervisormodules,andfabricmodulestoenablethehighestlevelofavailability
•RapidRingProtectionProtocol(RRPP)
ProvidesfastrecoveryforringEthernet-basedtopology
-
Page 5Data sheet
Quality of Service (QoS)•VirtualOutputQueue(VOQ)
Preventshead-of-line(HOL)blockingandgracefullyhandlesburstydatacentertrafficincreasingswitchperformance
•IEEE802.1pprioritization
Deliversdatatodevicesbasedonthepriorityandtypeoftraffic
•Layer4prioritization
EnablesprioritizationbasedonTCP/UDPportnumbers
•Broadcastcontrol
Allowslimitationofbroadcasttrafficratetocutdownonunwantednetworkbroadcasttraffic
•Advancedclassifier-basedQoS
ClassifiestrafficusingmultiplematchcriteriabasedonLayer2,3,and4information;appliesQoSpoliciessuchassettingprioritylevelandratelimittoselectedtrafficonaper-portorper-VLANbasis
•Bandwidthshaping
–Port-basedratelimiting
Providesper-portingress-/egress-enforcedmaximumbandwidth
–Classifier-basedratelimiting
UsesACLstoenforcemaximumbandwidthforingress/egresstrafficoneachport
Compartmentalization•Departmentprotection
Usingnetworkvirtualizationstandards(QinQ,VRF,andMPLS),the12500SwitchSeriesallowsorganizationstoisolatedifferentbusinessunitswithdifferentresources(VRFs);usingstandard-basedmechanisms,thenetworkiscompletelyvirtualized,reducingcostandoperations
•IEEE802.1ahProviderBackboneBridge(MACinMAC)
ProviderBackboneBridge(PBB)isaLayer2VPNtechnologythatallowsacompleteseparationofcustomerandproviderdomainsbysealingtheuserMACintheserviceproviderMAC,whichenhancesthescalabilityofanEthernetnetwork
-
Page 6Data sheet
Layer 2 switching•MultipleVLANRegistrationProtocol(MVRP)
HelpstomaintainVLANconfigurationdynamicallybasedoncurrentnetworkconfigurations
•GARPVLANRegistrationProtocol
AllowsautomaticlearninganddynamicassignmentofVLANs
•IPmulticastsnoopinganddata-drivenIGMP
AutomaticallypreventsfloodingofIPmulticasttraffic
•IEEE802.1adQinQ
IncreasesthescalabilityofanEthernetnetworkbyprovidingahierarchicalstructure;connectsmultipleLANsonahigh-speedcampusormetronetwork
•BridgeProtocolDataUnit(BPDU)tunneling
TransmitsSTPBPDUstransparently,allowingcorrecttreecalculationsacrossserviceproviders,WANs,orMANs
•VLANsupportandtagging
SupportsIEEE802.1Q(4KVLANIDs)
•SpanningTree
The12500SwitchSeriessupportstheentiresetofSTPprotocols(STP,RSTP,andMSTP),facilitatingacompleteintegrationwithstandardnetworks
Layer 3 routing•Layer3IPv4routing
ProvidesroutingofIPv4atmediaspeed;supportsstaticroutes,RIPandRIPv2,OSPF,IS-IS,andBGP
•RIPandRIPngsupport
ProvidescompletesupportofRIPforbothIPv4andIPv6
•OSPFandOSPFv3support
ProvidescompletesupportofOSPFforbothIPv4andIPv6
•IS-ISandIS-ISv6support
ProvidescompletesupportofIS-ISforbothIPv4andIPv6
•Equal-CostMultipath(ECMP)
Enablesmultipleequal-costlinksinaroutingenvironmenttoincreaselinkredundancyandscalebandwidth
•Layer3IPv6routing
ProvidesroutingofIPv6atmediaspeed;supportsstaticroutes,RIPng,OSPFv3,IS-ISv6,andBGP4+
•IPv6tunneling
AllowsasmoothtransitionfromIPv4toIPv6byencapsulatingIPv6trafficoveranexistingIPv4infrastructure
-
Page 7Data sheet
•Completemulticastprotocolstack
PIM-DM,PIM-SM,PIM-SSM,MSDP,andextensionstoBGPprovideoneofthemostcompletemulticastprotocolstacks
•Policyrouting
Allowscustomfiltersforincreasedperformanceandsecurity;supportsACLs,IPprefix,ASpaths,communitylists,andaggregatepolicies
•MPLSsupport
ProvidesextendedsupportofMPLS,includingMPLSVPNsandMPLSTrafficEngineering(MPLSTE)
•VPLSsupport
ProvidesextendedsupportofVPLSfordatacentertodatacentercommunicationatLayer2;providessupportofhierarchicalVPLSforscalability
Management•sFlow®
Providesscalable,ASIC-basednetworkmonitoringandaccounting;thisallowsnetworkoperatorstogatheravarietyofsophisticatednetworkstatisticsandinformationforcapacityplanningandreal-timenetworkmonitoringpurposes
•IEEE802.1ABLLDPdiscovery
Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications
•USBsupport
–Filecopy
AllowsuserstocopyswitchfilestoandfromaUSBflashdrive
•Multipleconfigurationfiles
Storeseasilytotheflashimage
•Command-lineinterface(CLI)
Providesasecure,easy-to-useCLIforconfiguringthemoduleviaSSHoraswitchconsole;providesdirectreal-timesessionvisibility
•Logging
ProvideslocalandremoteloggingofeventsviaSNMP(v2candv3)andsyslog;provideslogthrottlingandlogfilteringtoreducethenumberoflogeventsgenerated
•Managementinterfacecontrol
Enablesordisableseachofthefollowinginterfacesdependingonsecuritypreferences:consoleport,telnetport,andSSHport
•Out-of-bandinterface
Isolatesmanagementtrafficfromuserdataplanetrafficforcompleteisolationandtotalreachability,nomatterwhathappensinthedataplane
-
Page 8Data sheet
•Networkmanagement
HPEIntelligentManagementCenter(IMC)centrallyconfigures,updates,monitors,andtroubleshoots
•Networkmanagement
SNMPv2c/v3MIB-IIwithtraps
•RADIUSaccounting
Logsallsessiondetailsthatcanbeusedtogenerateusagereportsorinterfacetoabillingsystem
•RMON
Providesadvancedmonitoringandreportingcapabilitiesforstatistics,history,alarms,andevents
•RemoteIntelligentMirroring
MirrorsingressACL-selectedtrafficfromaswitchportorVLANtoalocalorremoteswitchportanywhereonthenetwork
Connectivity•IPv6nativesupport
– IPv6host
EnablesswitchestobemanagedanddeployedattheIPv6network’sedge
–Dualstack(IPv4andIPv6)
TransitionsfromIPv4toIPv6,supportingconnectivityforbothprotocols
–MulticastListenerDiscovery(MLD)snooping
ForwardsIPv6multicasttraffictotheappropriateinterface
– IPv6ACL/QoS
SupportsACLandQoSforIPv6networktraffic,preventingtrafficflooding
– IPv6routing
SupportsIPv6staticroutesandIPv6versionsofRIPandOSPFroutingprotocols
-
Page 9Data sheet
Security•ControlPlanePolicing(CoPP)
ProtectionagainstDoSattacksatinfrastructureroutersandswitches;easeofconfigurationforcontrolplanepolicies
•IEEE802.1XandRADIUSnetworklogins
Controlsport-basedaccessforauthenticationandaccountability
•SecureFTP
Allowssecurefiletransfertoandfromtheswitch;protectsagainstunwantedfiledownloadsorunauthorizedcopyingofaswitchconfigurationfile
•Switchmanagementlogonsecurity
HelpssecureswitchCLIlogonbyoptionallyrequiringeitherRADIUSorTACACS+authentication
•DHCPprotection
BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks
•DynamicARPprotection
BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftofnetworkdata
•SecureShell(SSHv2)
Encryptsalltransmitteddataforsecure,remoteCLIaccessoverIPnetworks
•Securemanagementaccess
Deliverssecureencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2andSNMPv3
•ACLs
ProvideIPv4andIPv6filteringbasedonsource/destinationIPaddress/subnetandsource/destinationTCP/UDPportnumber
•Mediaaccesscontrol(MAC)authentication
Providessimpleauthenticationbasedonauser’sMACaddress;supportslocalorRADIUS-basedauthentication
Convergence•Layers2,3,and4QoSmechanisms
SupportDiffServprioritytaggingbasedonIPaddress,IPTypeofService(ToS),Layer3protocol,TCP/UDPportnumber,andsourceport
•IPmulticastsnoopinganddata-drivenIGMP
AutomaticallypreventfloodingofIPmulticasttraffic
•LLDP-MED
Isastandardextensionthatautomaticallyconfiguresnetworkdevices,includingLLDP-capableIPphones
•InternetGroupManagementProtocol(IGMP)
UtilizesAny-SourceMulticast(ASM)orSource-SpecificMulticast(SSM)tomanageIPv4multicastnetworks;supportsIGMPv1,v2,andv3
•ProtocolIndependentMulticast(PIM)
DefinesmodesofInternetIPv4andIPv6multicastingtoallowone-to-manyandmany-to-manytransmissionofinformation;supportsPIMDenseMode(DM),SparseMode(SM),andSource-SpecificMode(SSM)
-
Page 10Data sheet
•MulticastSourceDiscoveryProtocol(MSDP)
AllowsmultiplePIM-SMdomainstointeroperate;isusedforinter-domainmulticastapplications
•MulticastVLAN
AllowsmultipleVLANstoreceivethesameIPv4orIPv6multicasttraffic,lesseningnetworkbandwidthdemandbyreducingoreliminatingmultiplestreamstoeachVLAN
Monitor and diagnostics•Portmirroring
Enablestrafficonaporttobesimultaneouslysenttoanetworkanalyzerformonitoring
•Connectivityfaultdetection(IEEE802.1ag)
Connectivityfaultdetection(CFD)providesaLayer2linkOperations,Administration,andMaintenance(OAM)mechanismusedforlinkconnectivitydetectionandfaultlocating
Integration•12500VPN20Gb/sFirewallModule
Providesenhancedstatefulpacketinspectionandfiltering;supportsflexiblesecurityzonesandvirtualfirewallcontainment;deliversadvancedVPNserviceswith3DESandAESencryptionathighperformanceandlowlatency;offersWebcontentfilteringandapplicationprioritizationandoptimization
Investment protection•Modularswitchfabric
Providesinvestmentprotectionbyenablingfutureperformanceupgradesandincreasedportdensity
•Environmentallyfriendly
RoHSsupportandlowpowerconsumptionbasedonthelatesttechnologyprovideoutstandingpowerefficiency
Warranty and support•1-yearwarranty
Seehpe.com/networking/warrantysummaryforwarrantyandsupportinformationincludedwithyourproductpurchase.
•Softwarereleases
Tofindsoftwareforyourproduct,refertohpe.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohpe.com/networking/warrantysummary
http://www.hpe.com/networking/warrantysummaryhttp://www.hpe.com/networking/supporthttp://www.hpe.com/networking/warrantysummaryhttp://www.hpe.com/networking/warrantysummary
-
HPE 12504 AC Switch Chassis (JC654A) HPE 12504 DC Switch Chassis (JC655A) HPE 12508 AC Switch Chassis (JF431C)
I/O ports and slots 4openmoduleslotsSupportsamaximumof192GigabitEthernetportsor1921/10GbEportsor6440GbEportsor16100GbEports,oracombination
4openmoduleslotsSupportsamaximumof192GigabitEthernetportsor1921/10GbEportsor6440GbEportsor16100GbEports,oracombination
8openmoduleslotsSupportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots4switchfabricslots
2MPU(formanagementmodules)slots4switchfabricslots
2MPU(formanagementmodules)slots9switchfabricslots
Physical characteristicsDimensions
WeightFullconfigurationweight
17.4(w)x27.87(d)x17.4(h)in.(44.2x70.8x44.2cm)(10Uheight)132.28lb(60kg)220.46lb(100kg)
17.4(w)x27.87(d)x17.4(h)in.(44.2x70.8x44.2cm)132.28lb(60kg)220.46lb(100kg)
17.4(w)x29.13(d)x38.39(h)in.(44.2x73.99x97.51cm)(22Uheight)209.44lb(95kg)374.78lb(170kg)
Memory and processorGigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.Telcorackorequipmentcabinet
MountsinanEIA-standard19in.Telcorackorequipmentcabinet
MountsinanEIA-standard19in.Telcorackorequipmentcabinet
PerformanceThroughputRouting/Switchingcapacity
1920Mpps3240Gb/s
1920Mpps3240Gb/s
3840Mpps6120Gb/s
EnvironmentOperatingtemperatureOperatingrelativehumidityNon-operating/StoragetemperatureNon-operating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
Page 11Data sheet
HPE 12500 Switch Series
Specifications
-
HPE 12504 AC Switch Chassis (JC654A) HPE 12504 DC Switch Chassis (JC655A) HPE 12508 AC Switch Chassis (JF431C)
Electrical characteristicsFrequency
Description
MaximumheatdissipationACvoltage
DCvoltageMaximumpowerrating
50/60Hz
8123BTU/hr(8569.77kJ/hr)100–120/200–240VAC,rated(90–264VAC,max)
2380W
8123BTU/hr(8569.77kJ/hr)
-48to-60VDC2380W
50/60HzAchieved Miercom Certified Green Award10GbEmodulesconsumehalfthepowercomparedtocompetitiveproducts;redundant,scalable,90%efficientpowersuppliesdeliverhighreliabilityinthedatacenter;newASICtechnologyhaslowpowerconsumptionwhenprovidingrichfeatures.14587BTU/hr(15389.29kJ/hr)100–120/200–240VAC,rated(90–264VAC,max)
4750W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
Page 12Data sheet
Specifications (Continued)
-
Page 13Data sheet
HPE 12504 AC Switch Chassis (JC654A) HPE 12504 DC Switch Chassis (JC655A) HPE 12508 AC Switch Chassis (JF431C)
ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Specifications (Continued)
http://www.hpe.com/networking/serviceshttp://www.hpe.com/networking/serviceshttp://www.hpe.com/networking/services
-
HPE 12508 DC Switch Chassis (JC652A) HPE 12518 DC Switch Chassis (JC653A)
I/O ports and slots 8openmoduleslotsSupportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
18openmoduleslotsSupportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots9switchfabricslots
2MPU(formanagementmodules)slots9switchfabricslots
Physical characteristicsDimensions
WeightFullconfigurationweight
17.4(w)x29.13(d)x38.39(h)in.(44.2x73.99x97.51cm)(22Uheight)209.44lb(95kg)374.78lb(170kg)
17.4(w)x29.13(d)x66.38(h)in.(44.2x73.99x168.61cm)(38Uheight)352.74lb(160kg)639.33lb(290kg)
Memory and processorGigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.Telcorackorequipmentcabinet
MountsinanEIA-standard19in.Telcorackorequipmentcabinet
PerformanceThroughputRouting/Switchingcapacity
3840Mpps6120Gb/s
8640Mpps13.3Tb/s
Page 14Data sheet
HPE 12500 Switch Series
Specifications
-
Page 15Data sheet
HPE 12508 DC Switch Chassis (JC652A) HPE 12518 DC Switch Chassis (JC653A)
EnvironmentOperatingtemperatureOperatingrelativehumidityNon-operating/StoragetemperatureNon-operating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
Electrical characteristicsFrequencyMaximumheatdissipationACvoltage
DCvoltageMaximumpowerrating
14587BTU/hr(15389.29kJ/hr)
-48to-60VDC4750W
32859BTU/hr(34666.24kJ/hr)
-48to-60VDC10700W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
Specifications (Continued)
-
Page 16Data sheet
HPE 12508 DC Switch Chassis (JC652A) HPE 12518 DC Switch Chassis (JC653A)
ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Specifications (Continued)
http://www.hpe.com/networking/serviceshttp://www.hpe.com/networking/services
-
HPE FlexFabric 12508E AC Switch Chassis (JG782A) HPE FlexFabric 12508E DC Switch Chassis (JG783A)
I/O ports and slots 8openmoduleslotsSupportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
8openmoduleslotsSupportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots9switchfabricslots
2MPU(formanagementmodules)slots9switchfabricslots
Physical characteristicsDimensions
WeightFullconfigurationweight
17.4(w)x29.13(d)x38.39(h)in.(44.2x74.0x97.51cm)(22Uheight)242.51lb(110kg)374.78lb(170kg)
17.4(w)x29.13(d)x38.39(h)in.(44.2x73.99x97.51cm)(22Uheight)209.44lb(95kg)374.78lb(170kg)
Memory and processorGigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.Telcorackorequipmentcabinet
MountsinanEIA-standard19in.Telcorackorequipmentcabinet
PerformanceThroughputRouting/Switchingcapacity
4800Mpps10.8Tb/s
4800Mpps10.8Tb/s
Page 17Data sheet
HPE 12500 Switch Series
Specifications (Continued)
-
Page 18Data sheet
HPE FlexFabric 12508E AC Switch Chassis (JG782A) HPE FlexFabric 12508E DC Switch Chassis (JG783A)
EnvironmentOperatingtemperatureOperatingrelativehumidityNon-operating/StoragetemperatureNon-operating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
Electrical characteristicsFrequency
Description
MaximumheatdissipationACvoltageDCvoltageMaximumpowerrating
50/60HzAchieved Miercom Certified Green Award10GbEmodulesconsumehalfthepowercomparedtocompetitiveproducts;redundant,scalable,90%efficientpowersuppliesdeliverhighreliabilityinthedatacenter;newASICtechnologyhaslowpowerconsumptionwhenprovidingrichfeatures.14587BTU/hr(15389.29kJ/hr)100–120/200–240VAC,rated(90–264VAC,max)
4750W
14587BTU/hr(15389.29kJ/hr)
-48to-60VDC4750W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
Specifications (Continued)
-
Page 19Data sheet
HPE FlexFabric 12508E AC Switch Chassis (JG782A) HPE FlexFabric 12508E DC Switch Chassis (JG783A)
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Specifications (Continued)
http://www.hpe.com/networking/serviceshttp://www.hpe.com/networking/services
-
HPE FlexFabric 12518E AC Switch Chassis (JG784A) HPE FlexFabric 12518E DC Switch Chassis (JG785A)
I/O ports and slots 18openmoduleslotsSupportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination
18openmoduleslotsSupportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots9switchfabricslots
2MPU(formanagementmodules)slots9switchfabricslots
Physical characteristicsDimensions
WeightFullconfigurationweight
17.4(w)x29.13(d)x66.38(h)in.(44.2x73.99x168.61cm)(38Uheight)352.74lb(160kg)639.33lb(290kg)
17.4(w)x29.13(d)x66.38(h)in.(44.2x73.99x168.61cm)(38Uheight)352.74lb(160kg)639.33lb(290kg)
Memory and processorGigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.Telcorackorequipmentcabinet
MountsinanEIA-standard19in.Telcorackorequipmentcabinet
PerformanceThroughputRouting/Switchingcapacity
10.8Bpps24.3Tb/s
10.8Bpps24.3Tb/s
EnvironmentOperatingtemperatureOperatingrelativehumidityNon-operating/StoragetemperatureNon-operating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
Page 20Data sheet
HPE 12500 Switch Series
Specifications (Continued)
-
Page 21Data sheet
HPE FlexFabric 12518E AC Switch Chassis (JG784A) HPE FlexFabric 12518E DC Switch Chassis (JG785A)
Electrical characteristicsFrequencyMaximumheatdissipationACvoltageDCvoltageMaximumpowerrating
50/60Hz32859BTU/hr(34666.24kJ/hr)100–120/200–240VAC,rated(90–264VAC,max)
10700W
32859BTU/hr(34666.24kJ/hr)
-48to-60VDC10700W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Specifications (Continued)
http://www.hpe.com/networking/serviceshttp://www.hpe.com/networking/services
-
StANDArDS AND PrOtOCOlS(appliestoallproductsinseries)
BGP RFC1657DefinitionsofManagedObjectsforBGPv4RFC1771BGPv4RFC1772ApplicationoftheBGPRFC1773ExperiencewiththeBGP-4Protocol
RFC1774BGP-4ProtocolAnalysisRFC1997BGPCommunitiesAttributeRFC1998PPPGandalfFZACompressionProtocolRFC2385BGPSessionProtectionviaTCPMD5
RFC2439BGPRouteFlapDampingRFC2796BGPRouteReflectionRFC2842CapabilityAdvertisementwithBGP-4RFC2858BGP-4Multi-ProtocolExtensionsRFC2918RouteRefreshCapability
Denial of service protection RFC2267NetworkIngressFiltering AutomaticFilteringofwell-knownDenialofServicePackets
CPUDoSProtectionRateLimitingbyACLs
Device management RFC1155StructureandMgmt.Information(SMIv1)RFC1157SNMPv1/v2cRFC1305NTPv3RFC1945HypertextTransferProtocol—HTTP/1.0RFC2452MIBforTCP6
RFC2454MIBforUDP6RFC2573(SNMPv3Applications)RFC2578-2580SMIv2RFC2579(SMIv2TextConventions)RFC2580(SMIv2Conformance)RFC2819(RMONgroupsAlarm,Event,History,andStatisticsonly)
RFC2819RMONRFC3417(SNMPTransportMappings)SNMPv3andRMONRFCsupportSSHv1/SSHv2SecureShellTACACS/TACACS+
General protocols IEEE802.1adQ-in-QIEEE802.1agServiceLayerOAMIEEE802.1ahProviderBackboneBridgesIEEE802.1DMACBridgesIEEE802.1pPriorityIEEE802.1QVLANsIEEE802.1sMultipleSpanningTreesIEEE802.1vVLANclassificationbyProtocolandPortIEEE802.1wRapidReconfigurationofSpanningTreeIEEE802.1XPAEIEEE802.3ab1000BASE-TIEEE802.3adLinkAggregation(LAG)IEEE802.3ae10-GigabitEthernet
IEEE802.3ahEthernetinFirstMileoverPointtoPointFiber—EFMFIEEE802.3ba40and100GigabitEthernetArchitectureIEEE802.3i10BASE-TIEEE802.3u100BASE-XIEEE802.3xFlowControlIEEE802.3z1000BASE-XRFC768UDPRFC783TFTPProtocol(revision2)RFC791IPRFC792ICMPRFC793TCPRFC826ARPRFC854TELNETRFC868TimeProtocol
RFC903RARPRFC951BOOTPRFC959FileTransferProtocol(FTP)RFC1027ProxyARPRFC1042IPDatagramsRFC1350TFTPProtocol(revision2)RFC1519CIDRRFC1542BOOTPExtensionsRFC1812IPv4RoutingRFC2131DHCPRFC2338VRRPRFC2784GenericRoutingEncapsulation(GRE)RFC2865RemoteAuthenticationDialInUserService(RADIUS)
IP multicast RFC1112IGMPRFC2236IGMPv2RFC2283Multi-protocolExtensionsforBGP-4
RFC2362PIMSparseModeRFC2934ProtocolIndependentMulticastMIBforIPv4RFC3376IGMPv3
RFC3618MulticastSourceDiscoveryProtocol(MSDP)RFC4601PIMSparseMode
Page 22Data sheet
-
Page 23Data sheet
StANDArDS AND PrOtOCOlS(appliestoallproductsinseries)
IPv6 RFC1350TFTPRFC1981IPv6PathMTUDiscoveryRFC2080RIPngforIPv6RFC2460IPv6SpecificationRFC2461IPv6NeighborDiscoveryRFC2462IPv6StatelessAddressAuto-configurationRFC2463ICMPv6RFC2473GenericPacketTunnelinginIPv6RFC2475IPv6DiffServArchitectureRFC2529TransmissionofIPv6PacketsoverIPv4
RFC2710MulticastListenerDiscovery(MLD)forIPv6RFC2740OSPFv3forIPv6RFC2893TransitionMechanismsforIPv6HostsandRoutersRFC2925DefinitionsofManagedObjectsforRemotePing,Traceroute,andLookupOperations(Pingonly)RFC3315DHCPv6(clientonly)RFC3484DefaultAddressSelectionforIPv6RFC3513IPv6AddressingArchitecture
RFC3587IPv6GlobalUnicastAddressFormatRFC3810MulticastListenerDiscoveryVersion2(MLDv2)forIPv6RFC4251SSHv6ArchitectureRFC4252SSHv6AuthenticationRFC4253SSHv6TransportLayerRFC4254SSHv6ConnectionRFC4541IGMP&MLDSnoopingSwitchRFC4862IPv6StatelessAddressAuto-configuration
MIBs IEEE8023-LAG-MIBRFC1213MIBIIRFC1229InterfaceMIBExtensionsRFC1286BridgeMIBRFC1493BridgeMIBRFC1573SNMPMIBIIRFC1643EthernetMIBRFC1657BGP-4MIBRFC1724RIPv2MIBRFC1757RemoteNetworkMonitoringMIBRFC1850OSPFv2MIBRFC2011SNMPv2MIBforIPRFC2012SNMPv2MIBforTCPRFC2013SNMPv2MIBforUDPRFC2021RMONv2MIBRFC2096IPForwardingTableMIBRFC2233InterfacesMIB
RFC2273SNMP-NOTIFICATION-MIBRFC2452IPV6-TCP-MIBRFC2454IPV6-UDP-MIBRFC2465IPv6MIBRFC2466ICMPv6MIBRFC2571SNMPFrameworkMIBRFC2572SNMP-MPDMIBRFC2573SNMP-TargetMIBRFC2613SMONMIBRFC2618RADIUSClientMIBRFC2620RADIUSAccountingMIBRFC2665Ethernet-Like-MIBRFC2674802.1pandIEEE802.1QBridgeMIBRFC2737EntityMIB(Version2)RFC2787VRRPMIBRFC2819RMONMIBRFC2863TheInterfacesGroupMIB
RFC2925PingMIBRFC2932IP(MulticastRoutingMIB)RFC2933IGMPMIBRFC3273HC-RMONMIBRFC3414SNMP-Userbased-SMMIBRFC3415SNMP-Viewbased-ACMMIBRFC3418MIBforSNMPv3RFC3621PowerEthernetMIBRFC3813MPLSLSRMIBRFC3814MPLSFTNMIBRFC3815MPLSLDPMIBRFC3826AESforSNMP’sUSMMIBRFC4133EntityMIB(Version3)LLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBLLDP-MIB
MPlS RFC2205ResourceReSerVationProtocol(RSVP)—Version1FunctionalSpecificationRFC2209ResourceReSerVationProtocol(RSVP)RFC2702RequirementsforTrafficEngineeringOverMPLSRFC2858Multi-protocolExtensionsforBGP-4RFC3031Multi-protocolLabelSwitchingArchitectureRFC3032MPLSLabelStackEncodingRFC3036LDPSpecificationRFC3107CarryingLabelInformationinBGP-4
RFC3209RSVP-TE:ExtensionstoRSVPforLSPTunnelsRFC3479FaultTolerancefortheLabelDistributionProtocol(LDP)RFC3487GracefulRestartMechanismforLDPRFC4090FastRerouteExtensionstoRSVP-TEforLSPTunnelsRFC4364BGP/MPLSIPVirtualPrivateNetworks(VPNs)RFC4379DetectingMulti-ProtocolLabelSwitched(MPLS)DataPlaneFailuresRFC4447PseudowireSetupandMaintenanceUsingLDP
RFC4448EncapsulationMethodsforTransportofEthernetoverMPLSNetworksRFC4664FrameworkforLayer2VirtualPrivateNetworksRFC4665ServiceRequirementsforLayer2ProviderProvisionedVirtualPrivateNetworksRFC4761VirtualPrivateLANService(VPLS)UsingBGPforAuto-DiscoveryandSignalingRFC4762VirtualPrivateLANService(VPLS)UsingLabelDistributionProtocol(LDP)Signaling
(CONtINuED)
-
Page 24Data sheet
StANDArDS AND PrOtOCOlS(appliestoallproductsinseries)
Network management IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)IEEE802.1D(STP)RFC1155StructureofManagementInformationRFC1157SNMPv1RFC1215SNMPGenerictrapsRFC1757RMON4groups:Stats,History,Alarms,andEvents
RFC1905SNMPv2ProtocolOperationsRFC2211Controlled-LoadNetworkRFC2272SNMPv3ManagementProtocolRFC2273SNMPv3ApplicationsRFC2274USMforSNMPv3RFC2571SNMPManagementFrameworksRFC2572SNMPv3MessageProcessingRFC2573SNMPv3ApplicationsRFC2576CoexistencebetweenSNMPversions
RFC2578SMIv2RFC2819FourgroupsofRMON:1(statistics),2(history),3(alarm),and9(events)RFC3164BSDsyslogProtocolRFC3415SNMPv3View-basedAccessControlModel(VACM)ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)SNMPv1/v2c/v3
OSPF RFC1245OSPFprotocolanalysisRFC1246ExperiencewithOSPFRFC1587OSPFNSSA
RFC1765OSPFDatabaseOverflowRFC1850OSPFv2ManagementInformationBase(MIB),trapsRFC2328OSPFv2
RFC2370OSPFOpaqueLSAOptionRFC3101OSPFNSSARFC3623GracefulOSPFRestart
QoS/CoS IEEE802.1p(CoS)RFC2212GuaranteedQualityofServiceRFC2474DSFieldintheIPv4andIPv6Headers
RFC2475DiffServArchitectureRFC2597DiffServAssuredForwarding(AF)RFC2598DiffServExpeditedForwarding(EF)
RFC2697ASingleRateThreeColorMarkerRFC2698ATwoRateThreeColorMarkerBidirectionalRateShaping
Security IEEE802.1AEMACSecurityStandard(MACSec)IEEE802.1XPortBasedNetworkAccessControlRFC1321TheMD5Message-DigestAlgorithmRFC2082RIP-2MD5AuthenticationRFC2104Keyed-HashingforMessageAuthentication
RFC2716PPPEAPTLSAuthenticationProtocolRFC2865RADIUSAuthenticationRFC2866RADIUSAccountingRFC2867RADIUSAccountingModificationsforTunnelProtocolSupportRFC2868RADIUSAttributesforTunnelProtocolSupport
RFC2869RADIUSExtensionsRFC3567IntermediateSystem(IS)toISCryptographicAuthenticationAccessControlLists(ACLs)GuestVLANfor802.1XMACAuthenticationSSHv2SecureShellWebAuthentication
IKEv1 RFC2865—RemoteAuthenticationDialInUserService(RADIUS)
(CONtINuED)
-
Modules HPEFlexFabric12500EMainProcessingUnit(JG802A)HPE12500TypeAMainProcessingUnitwithComwarev7OperatingSystem(JG497A)HPE12500MainProcessingUnit(JC072B)HPEFlexFabric125004-port100GbECFPFDModule(JG786A)HPEFlexFabric125004-port100GbECFPFGModule(JG788A)HPEFlexFabric1250016-port40GbEQSFP+FDModule(JG790A)HPEFlexFabric1250048-port1/10GbESFP+FDModule(JG796A)HPEFlexFabric1250040-port1/10GbESFP+FDModule(JG792A)HPEFlexFabric1250040-port1/10GbESFP+FGModule(JG794A)HPE1250016-port10GbESFP+LEBModule(JC782A)HPE1250016-port10GbESFP+LECModule(JC783A)HPE1250032-port10GbESFP+REBModule(JC064B)HPE1250032-port10GbESFP+RECModule(JC476B)HPE125008-port10GbESFP+LEBModule(JC780A)HPE125008-port10GbESFP+LECModule(JC781A)HPE125008-port10GbESFP+LEFModule(JC659A)HPE1250048-portGig-TLEBModule(JC074B)HPE1250048-portGig-TLECModule(JC065B)HPE1250048-portGbESFPLEBModule(JC075B)HPE1250048-portGbESFPLECModule(JC069B)HPE1250048-portGbESFPLEFModule(JC660A)
HPE 12500 Switch Series accessories
Page 25Data sheet
-
transceivers HPEX120100M/1GSFPLCLXTransceiver(JF832A)HPEX114100MSFPLCFXTransceiver(JF833A)HPEX1251GSFPLCLH401310nmTransceiver(JD061A)HPEX1201GSFPLCLH401550nmTransceiver(JD062A)HPEX1251GSFPLCLH70Transceiver(JD063B)HPEX1201GSFPRJ45TTransceiver(JD089B)HPEX1201GSFPLCBX10-UTransceiver(JD098B)HPEX1201GSFPLCBX10-DTransceiver(JD099B)HPEX1201GSFPLCLH100Transceiver(JD103A)HPEX1701GSFPLCLH701550Transceiver(JD109A)HPEX1701GSFPLCLH701570Transceiver(JD110A)HPEX1701GSFPLCLH701590Transceiver(JD111A)HPEX1701GSFPLCLH701610Transceiver(JD112A)HPEX1701GSFPLCLH701470Transceiver(JD113A)HPEX1701GSFPLCLH701490Transceiver(JD114A)HPEX1701GSFPLCLH701510Transceiver(JD115A)HPEX1701GSFPLCLH701530Transceiver(JD116A)HPEX1201GSFPLCSXTransceiver(JD118B)HPEX1201GSFPLCLXTransceiver(JD119B)HPEX13010GSFP+LCSRTransceiver(JD092B)HPEX13010GSFP+LCLRMTransceiver(JD093B)HPEX13010GSFP+LCLRTransceiver(JD094B)HPEX13010GSFP+LCER40kmTransceiver(JG234A)HPEX24010GSFP+toSFP+3mDirectAttachCopperCable(JD097C)HPEX24010GSFP+toSFP+5mDirectAttachCopperCable(JG081C)HPEX24010GSFP+SFP+7mDirectAttachCopperCable(JC784C)HPEX14040GQSFP+MPOSR4Transceiver(JG325B)HPEX14040GQSFP+MPOMM850nmCSR4300mTransceiver(JG709A)HPEX14040GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)HPEX14040GQSFP+LCBiDi100mMMTransceiver(JL251A)HPEX150100GCFPLCLR410kmSMTransceiver(JG829A)HPEX13010GSFP+LCLH80kmTransceiver(JG915A)
Cables HPEPremierFlexLC/LCMulti-modeOM42fiber1mCable(QK732A)HPEPremierFlexLC/LCMulti-modeOM42fiber2mCable(QK733A)HPEPremierFlexLC/LCMulti-modeOM42fiber5mCable(QK734A)HPEPremierFlexLC/LCMulti-modeOM42fiber15mCable(QK735A)HPEPremierFlexLC/LCMulti-modeOM42fiber30mCable(QK736A)HPEPremierFlexLC/LCMulti-modeOM42fiber50mCable(QK737A)
Mounting Kit HPEX421ChassisUniversal4-postRackMountingKit(JC665A)
Appliance HPE1250020GbpsVPNFirewallModule(JG371A)
HPE 12500 Switch Series accessories (continued)
Page 26Data sheet
-
HPE 12500 Switch Series accessories (continued)
Page 27Data sheet
Memory HPEFlexFabric4GBCompactFlashCard(JG806A)HPEFlexFabric4GBDDR3SDRAM(JG807A)HPEX6001GCompactFlashCard(JC684A)HPE2GBRegisteredDDR2SDRAMMemory(JC609A)HPEX6101GBDDR2SDRAMMemory(JC071A)
HPE 12504 AC Switch Chassis (JC654A) HPE1250xG2FabricModule(JC658A)HPE12500ACPowerEntryModule(JF426A)HPE125002000WACPowerSupply(JF429A)HPE12504FanAssembly(JC664A)
HPE 12504 DC Switch Chassis (JC655A) HPE1250xG2FabricModule(JC658A)HPEX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)HPE125001800WDCPowerSupply(JC651A)HPE12504FanAssembly(JC664A)
HPE 12508 AC Switch Chassis (JF431C) HPE12508FabricModule(JC067B)HPE1250xG2FabricModule(JC658A)HPE125002000WACPowerSupply(JF429A)HPE12500ACPowerEntryModule(JF426A)
HPE 12508 DC Switch Chassis (JC652A) HPE12508FabricModule(JC067B)HPE1250xG2FabricModule(JC658A)HPEX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)HPE125001800WDCPowerSupply(JC651A)
HPE 12518 DC Switch Chassis (JC653A) HPE12518G2FabricModule(JC657A)HPE12518FabricModule(JC066A)HPEX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)HPE125001800WDCPowerSupply(JC651A)
HPE FlexFabric 12508E AC Switch Chassis (JG782A) HPEFlexFabric12508EFabricModule(JG798A)HPEFlexFabric12508EOptionalExtendedCableGuideforACPoweredSwitch(JG830A)HPEFlexFabric12508EOptionalExtendedCableGuideforDCPoweredSwitch(JG832A)HPE125002000WACPowerSupply(JF429A)HPEFlexFabric12500ESparePowerMonitorModule(JG804A)HPEFlexFabric12500EFanTrayAssembly(JG805A)HPEFlexFabric12508EOptionalAirFilter(JG808A)
-
Ratethisdocument
Sign up for updates
Data sheet
©Copyright2010–2016HewlettPackardEnterpriseDevelopmentLP.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHewlettPackardEnterpriseproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HewlettPackardEnterpriseshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.
MicrosoftiseitheraregisteredtrademarkortrademarkofMicrosoftCorporationintheUnitedStatesand/orothercountries.sFlowisaregisteredtrademarkofInMonCorp.
4AA3-0666ENW,February2016,Rev.15
HPE FlexFabric 12508E DC Switch Chassis (JG783A) HPEFlexFabric12508EFabricModule(JG798A)HPE12508TopandBottomCableGuidesforDCPoweredSwitch(JC787A)HPE12500SideCableManagementGuide(JC084A)HPEX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)HPEFlexFabric12508EOptionalExtendedCableGuideforDCPoweredSwitch(JG832A)HPE125001800WDCPowerSupply(JC651A)HPEFlexFabric12500ESparePowerMonitorModule(JG804A)HPEFlexFabric12500EFanTrayAssembly(JG805A)HPEFlexFabric12508EOptionalAirFilter(JG808A)
HPE FlexFabric 12518E AC Switch Chassis (JG784A) HPEFlexFabric12518EFabricModule(JG800A)HPE12518TopandBottomCableGuidesforACPoweredSwitch(JC786A)HPE12500SideCableManagementGuide(JC084A)HPEFlexFabric12518EOptionalExtendedCableGuideforACPoweredSwitch(JG831A)HPE125002000WACPowerSupply(JF429A)HPE12500ACPowerEntryModule(JF426A)HPEFlexFabric12500ESparePowerMonitorModule(JG804A)HPEFlexFabric12500EFanTrayAssembly(JG805A)HPEFlexFabric12518EOptionalAirFilter(JG809A)
HPE FlexFabric 12518E DC Switch Chassis (JG785A) HPEFlexFabric12518EFabricModule(JG800A)HPE12518TopandBottomCableGuidesforDCPoweredSwitch(JC788A)HPE12500SideCableManagementGuide(JC084A)HPEX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)HPEFlexFabric12518EOptionalExtendedCableGuideforDCPoweredSwitch(JG833A)HPE125001800WDCPowerSupply(JC651A)HPEFlexFabric12500ESparePowerMonitorModule(JG804A)HPEFlexFabric12500EFanTrayAssembly(JG805A)HPEFlexFabric12518EOptionalAirFilter(JG809A)
HPE 12500 Switch Series accessories (continued)
ProductswithinthisserieshaveachievedsufficientscoresineachoftheratedcriteriatoachievetheMiercomCertifiedGreendistinctionAward.SeetheSpecificationssectionofthisseriesformoreinformation.
Learnmoreathpe.com/networking
http://www.facebook.com/sharer.php?u=http://h20195.www2.hp.com/V2/GetDocument.aspx?docname=4AA3-0666ENWhttp://www.linkedin.com/shareArticle?mini=true&ro=true&url=http%3A%2F%2Fh20195%2Ewww2%2Ehp%2Ecom%2FV2%2FGetDocument%2Easpx%3Fdocname%3D4AA3-0666ENW&title=HPE+12500+Switch+Series+&armin=arminhttp://twitter.com/home/?status=HPE%2012500%20Switch%20Series+%40+http%3A%2F%2Fh20195.www2.hp.com%2FV2%2FGetDocument.aspx?docname=4AA3-0666ENWhttp://www.hpe.com/info/getupdatedhttps://hpresearch.az1.qualtrics.com/SE/?SID=SV_6EuQKOr2Ku1CUzH&Pubnumber=4AA3-0666ENWhttp://www.hpe.com/networking