HP 8921A Cell Site Test Set
Product Note 8921-1
AMPSBase Station Testing
-
8/2/2019 HP8921A Product Note
2/16
This product note describes man-ual operation of the HP 8921ACell Site Test Set (or HP 8920A RFCommunications Test Set withoptions 001, 002, 003, 004, 005,013, 014) for testing AdvancedMobile Phone System (AMPS)Cellular Base Station equipment.It will lead you through the stepsrequired to set-up the instrumentin the proper state to make par-ticular measurements. Storingthese instrument states in mem-ory registers allows you to quickly
recall them without having to gothrough the laborious task of cre-ating them each time you want tomake a measurement on your
base station equipment.
For automated base station test-ing, Hewlett-Packard offersHP 11807B Cell Site Test Softwarefor use with the HP 8921A CellSite Test Set. The HP 11807B soft-ware has options that cover themost widely used AMPS base sta-tions. Each option uses test and
adjustment procedures derivedfrom the manufacturers mainte-nance manuals. For more infor-mation on this and otherHewlett-Packard products, con-tact your local Hewlett-Packardrepresentative.
Cell Site Overview
A cell site contains three types ofradios: control, voice, and locate.When a mobile originates a call or
is paged, the cell site control radiosets up the call. This control radiocommunicates with the centralswitch (Electronic Mobile Ex-change (EMX), Mobile SwitchingCenter (MSC), and Mobile Tele-
phone Switching Office (MTSO))to connect the call to another mo-
bile or landline phone. The mobileis then instructed by the cell sitecontrol channel to tune to a par-ticular voice channel.
The conversation takes place on
the voice radios with the voicesignals traveling back to the MSCand routed to the other party.
The locate, or scanner, radio isused to monitor the signal levelsof the channels and notifies theswitch enabling it to make hand-off decisions. This radio is receiveonly and, like the voice and con-trol radios, is controlled by dis-tributed control functions
between the MSC and local cellsite controller. Communication ofthese control functions takes
place via either a landline or mi-crowave transmission data link.
Cell sites are configured as omni-directional, sectored, or somecombination of the two. In gen-
eral, an omni-directional cell willhave two receive antennas and onetransmit antenna.
2
AMPS Base Station Testing
Cellular System Overview
-
8/2/2019 HP8921A Product Note
3/16
The two receive antennas arephysically separated to get betterimmunity to multipath fading con-ditions and are typically spacediversity antennas. Other omnisites may have only two receiveantennas to save money. In thiscase, one receive path is coupledto the same antenna as the trans-mit path. A tuned cavity duplexer
(combined receive and transmitfilter) is then used to keep the sig-nal paths separated.
A directional, or sectored, cellsplits the coverage into sectorswhich are served by different an-tennas. Typically, a directionalcell will have three sectored re-ceive antennas, one omni receiveantenna, three sectored transmitantennas, and one omni transmitantenna. Voice radios are config-ured on one face of the cell for
both transmit and receive and thelocate radio accepts inputs fromall of the receive antennas. Theone omni-transmit antenna is usedfor control channel transmit.When testing base station equip-ment in directional cells, you will
be working with radios
configured to different antennas.
Gain/loss for each antenna pathwill have to be taken into consid-eration for power measurementsand switching between receiveantennas for testing receiver sen-sitivity may also be necessary.
3
Basic Omni Cell Site Setup
3 - Sector Directional Site
-
8/2/2019 HP8921A Product Note
4/16
Base Station Tests
Standard tests to make on basestation equipment include receive,transmit, and system tests. This
product note outlines the follow-ing tests for cell site transceivers:
The following System Test proce-dures are NOT INCLUDED in this
product note. However, you canfind detailed procedures for thesetests in the HP 8920A RF Commu-
nications Test Set ApplicationsHandbook (Hewlett-Packard PN08920-90126).
Cell Site Connections
The basic connections requiredfor performing the manual tests inthis application note include TX,RX, and audio. Because eachmanufacturers base station equip-ment may connect to the HP8921A Cell Site Test Set differ-ently, it will be up to you to deter-mine how best to connect yourtransceivers to theHP 8921A.
Test Set Operation
This product note assumes theuser has some familiarity with thegeneral use of the HP 8921A CellSite Test Set (or HP 8920A RFCommunications Test Set). If thisis not the case, please refer to theHP 8921A Cell Site Test Set UsersGuide and the HP 8920A RF Com-munications Test Set ApplicationsHandbook for an overview of itsfunctions, features, andcapabilities.
This product note also assumesthat the user is familiar with theoperation of the Base Station un-der test. It is not the intent of thisnote to show the step-by-step set-ups required for setting up all
base stations for particular meas-urements since many base sta-tions have unique setups andcontrol options. However, when a
particular base station setup isrequired, it will be called out inthe setup procedure.
4
Transmitter Tests
Frequency Error/OffsetOutput PowerSAT Frequency Error and
DeviationVoice DeviationData Deviation
Receiver Tests
Sensitivity (SINAD)Squelch Threshold
System Tests
(not included)
Antenna Return Loss (VSWR)Cable Fault LocationField Strength Measurements
AMPS Base Station Testing
-
8/2/2019 HP8921A Product Note
5/16
HP 8921A Cell Site TestSet Overview
The HP 8921A Cell Site Test Set is
a single instrument that combinesthe features of 22 individual radiotest instruments. TheHP 8921A is designed to meet thecommunication needs of bothservice and manufacturing envi-ronments, and has the capabilityto test AMPS and TACS Base Sta-tions, cellular phones, and variousother communications systems.
Test and troubleshooting time isdecreased by simplifying standardmeasurement tasks and providing
the required measurement capa-bility in a single instrument.Transmitters and receivers arecharacterized with single-key RX,TX, and duplex tests. Each ofthese tests displays a specializedscreen that provides access to thenecessary controls and measure-ment results. Measured resultsmay be displayed as digital read-outs and/or bar graphs. All set-tings and measurements are easilyaccessed and changed using thefront panel knob and keys. If de-
sired, all settings can be saved innonvolatile save/recall registersfor future access.
The various ports on the HP8921A allow thereceiver/transmitter being testedto be quickly connected. A re-ceiver with 2 V sensitivity (typi-
cally
-
8/2/2019 HP8921A Product Note
6/16
Explanations:
The RF Display fieldselects the format forentering the RF Analyzerfrequencies:
* When Freq. is selected,
you enter the RF
Generator and RFAnalyzer frequencies
directly using the keypad
or knob.
* When Chan is selected,
the RF Gen Freq and
Tune Freq fields on all
screens are replaced by
the RF Channel field,
and only the channel
number is entered and
displayed.
The RF Chan Std field al-lows you to select thechannel standard for the ra-dio under test. The RF Gen-erator and RF Analyzerfrequencies will be auto-matically set to correspondto the channel number en-tered in the RF Channelfield. This field also sets the
correct TX/RX frequencyoffset (45 MHz for AMPS).
The RF Level Offset fieldenables/disables the effectsof the RF In/Out, DuplexOut, andAntenna In fields
below it. These fields areused if you wish to take intoaccount losses due to cablesand/or splitters in yoursetup.
* When set to Yes, the RF
Generator amplitude andRF Analyzer power
measurement are offset
by the values entered in
these fields.
* When set to No, the
values in these fields are
ignored. The values can,
however, be left in the
three fields.
For example, enter "-3.5"into the RF In/Out field forthe approximate total lossdue to a 1 meter cable and 3
dB splitter.
From the front panel of theHP 8921A, enter the "Config-ure" screen. Set the RF Dis-play and RF Chan Std asseen here and the RF LevelOffset as desired.
6
AMPS Base Station Testing
Screen Configuration
C
B
A
-
8/2/2019 HP8921A Product Note
7/16
PerformingMeasurements
The following measurement pro-cedures assume the HP 8921AConfigure screen is setup as de-scribed in the previous section. If
the instrument has been presetsince then, you will need to re-configure that screen.
7
Transmitter TestsTransmitter Frequency Error/Offset and Power . . . page 8Transmitter SAT Frequency and Deviation . . . . . . . page 9Transmitter Maximum Voice Deviation . . . . . . . . . . page 10Transmitter Data Deviation . . . . . . . . . . . . . . . . . . . page 11
Connect the Base Station to the HP 8921A according to thefollowing diagram.
RX Audio Out
TX Audio InRX Input
TX OutputFrom Base
StationFrom Base
Station}{
-
8/2/2019 HP8921A Product Note
8/16
Channel: As desiredTX Power Level: As desiredTX Power: OnSAT: OffData: Off
Step 1:Press the TX key on the HP 8921A to enter the transmitter test screen.
Step 2:Change the settings in the TX screen as seen in the highlighted areas.
Key instrument considerationsWith the front panel keys, enter the same RF Channel as set on the
base station.
Disable the FM Deviation andAF Freq measurements by scrollingto their units fields and pressing the On/Offkey.
Step 3:
The transmitter frequency error and power should now be displayed in theappropriate result fields. For TX Output Power in units other than Watts,scroll to and highlight the TX Power units field and press the appropriateunits key.
Step 4:Save this measurement setup as FREQ.
8
Base Station Setup
HP 8921A Cell SiteTest Set Setup
A
Transmitter Frequency Error/Offset
and Power
B
-
8/2/2019 HP8921A Product Note
9/16
Channel: As desiredTX Power Level: As desiredTX Power: OnSAT: OnData: Off
Step 1:Press the TX key on the HP 8921A to enter the transmitter test screen.
Step 2:Change the settings in the TX screen as seen in the highlighted areas.
Key instrument considerationsEnter the same RF Channel as set on the base station.
If you are using an HP 8920A RF Communications Test Set, youmust have Option 014 (6 kHz BPF) in order to choose this filter. Ifnot, you can use the 15 kHz LPF. The 6 kHz BPF is standard on theHP 8921A.
AFGen1 Lvl must be "OFF" or it may interfere with the SATmeasurement.
Disable the TX Freq Error and TX Power measurements by scroll-ing to their units fields and pressing the On/Offkey.
Step 3:The SAT frequency and deviation should now be displayed in the appropri-ate result fields. ForAF Freq in units other than Hz, scroll to and highlighttheAF Freq units field and press the appropriate units key.
Step 4:Save this measurement setup as SAT.
9
Transmitter SAT Frequency and Deviation
Base Station Setup
HP 8921A Cell SiteTest Set Setup
A
B
C
D
-
8/2/2019 HP8921A Product Note
10/16
Channel: As desiredTX Power Level: As desiredTX Power: OnSAT: OffData: Off
Step 1:Press the TX key on the HP 8921A to enter the transmitter test screen.
Step 2:Change the settings in the TX screen as seen in the highlighted areas.
Key instrument considerationsEnter the same RF Channel as set on the base station.
ForAFGEN1 Lvl, enter an initial value of 50 mv and set an incre-ment for this field of 20 dB.
Disable the TX Freq Error and TX Power by scrolling to theirunits fields and pressing the On/Offkey.
Step 3:Scroll to theAFGen1 Lvl field and depress the Up-Arrow key once. Thiswill increment theAFgen1 Lvl by 20 dB (as set above).
Step 4:The maximum voice deviation should now be displayed in theFM Deviation result field.
Step 5:Save this setup as MAX_VOICE.
10
Transmitter Maximum Voice Deviation
Base Station Setup
HP 8921A Cell SiteTest Set Setup
A
B
C
-
8/2/2019 HP8921A Product Note
11/16
Channel:As desired
TX Power Level:As desiredTX Power: OnSAT: OffData: On
Step 1:Press the TX key on the HP 8921A to enter the transmitter test screen.
Step 2:Change the settings in the TX screen as seen in the highlighted areas.
Key instrument considerationsEnter the same RF Channel as set on the base station.
AFGen1 Lvl must be "OFF" or it may interfere with the DATAmeasurement.
Disable the TX Freq Error, TX Power, and AF Freq measure-ments by scrolling to their units fields and pressing the On/Offkey.
Step 3:The Data Deviation should now be displayed in the FM Deviation resultfield.
Step 4:Save this measurement setup as DATA.
11
Transmitter Data Deviation
Base Station Setup
HP 8921A Cell SiteTest Set Setup
C
A
B
-
8/2/2019 HP8921A Product Note
12/16
12
Receiver Measurements
Receiver Sensitivity (SINAD) . . . . . . . . . . . . . . page 13
Receiver Squelch Threshold . . . . . . . . . . . . . . . page 14
Connect the Base Station to the HP 8921A according to thefollowing diagram. Note the Audio In connection. This must be connected
properly for accurate receiver audio measurements
Using the front-panel knob, scroll to and select the AF ANL screen, and select 600 TO HI in the Audio INLO field. 600 TO Hi establishes a 600 impedance between the center pins of the Audio IN LO and AudioIN HI connectors.
RX Audio Out
TX Audio InRX Input
TX OutputFrom Base
Station
From Base
Station
}{
Audio IN
-
8/2/2019 HP8921A Product Note
13/16
Channel: As desiredTX Power Level: As desiredTX Power: OffSAT: OffData: OffSquelch: Off
Step 1:Press the RX key on the HP 8921A to enter the receiver test screen.
Step 2:Change the settings in the RX screen as seen in the highlighted areas.
Key instrument considerationsEnter the same RF Channel as set on the base station.
Enter an initial value in the amplitude field. This value will depend
on the sensitivity of the receiver you are testing.
Step 3:Using the front-panel knob, adjust theAmplitude until the desired SINADis measured. To adjust the resolution of the amplitude adjustment, use the
INCR SET, INCR 10, or INCR 10 keys.
Step 4:Save this measurement setup as SINAD.
13
Receiver Sensitivity (SINAD)
Base Station Setup
HP 8921A Cell SiteTest Set Setup
A
B
-
8/2/2019 HP8921A Product Note
14/16
Channel: As desiredTX Power Level: As desiredTX Power: OffSAT: OffData: OffSquelch: On
Step 1:Press the RX key on the HP 8921A to enter the receiver test screen.
Step 2:Change the settings in the RX screen as seen in the highlighted areas.
Key instrument considerationsEnter the same RF Channel as set on the base station.
Enter a starting amplitude. This initial amplitude value will de-
pend on the squelch sensitivity of your receiver.
It is important to activate theAtten Hold function of the HP
8921A for this test. If this is not done, the RF signal to the receiver
may drop out momentarily as you adjust its amplitude and an at-
tenuator change is required. This will activate the squelch on the re-
ceiver and make it difficult to measure the squelch sensitivity.
14
Receiver Squelch Threshold
Base Station Setup
HP 8921A Cell SiteTest Set Setup
A
B
C
-
8/2/2019 HP8921A Product Note
15/16
Step 3:Adjust the volume on the HP 8921A to verify audio output. If no audio is
heard, the base station may be in a squelched condition. In this case, in-
crease the amplitude until the squelch de-activates and an audio signal is
heard.
With the amplitude field highlighted, slowly decrease the amplitude of the
RF signal and note the point at which the squelch activates and the audiosignal is muted. To adjust the resolution of the amplitude adjustment, use
the INCR SET, INCR
10, or INCR
10 keys.
For squelch hysteresis testing, slowly increase the RF level until thesquelch de-activates and an audio signal is present. Note the RF level atwhich this occurs. The squelch hysteresis is the difference between thislevel and the level at which the squelch activates.
Step 4:Save this measurement setup as SQUELCH.
Typical AMPS System Specifications
15
Parameter Specification
TX Frequency Error 1.5 ppm
TX Sat
Frequency 1 Hz
Deviation 2 kHz 10%
TX Voice
Nominal Deviation 8 kHz 10%
Maximum Deviation 12 kHz
TX Wideband Data
Deviation 8 kHz 10%
RX Sensitivity (SINAD) < -116 dBm @ 12 dB SINAD
Appendix A
-
8/2/2019 HP8921A Product Note
16/16
Data subject to change
Hewlett-Packard Company 1997
Printed in U.S.A. 5/97
5962-9475E
For more information on Hewlett-
Packard Test & Measurement products,
applications or services please call
your local Hewlett-Packard sales
offices. A current listing is available via Web through
http://www.hp.com./go/tmdir
If you do not have access to the
internet please contact one of the
HP centers listed below and they
will direct you to your nearest
HP representative.
United States:
Hewlett-Packard Company
Test and Measurement Organization
5301 Stevens Creek Blvd.
Bldg. 51L-SC
Santa Clara, CA 95052-8059
1 800 452 4844
Canada:
Hewlett-Packard Canada Ltd.
5150 Spectrum Way
Mississauga, Ontario
L4W 5G1
(905) 206 4725
Europe:
Hewlett-Packard
European Marketing Center
P.O. Box 999
1180 AZ Amstelveen
The Netherlands
Japan:
Hewlett-Packard Japan Ltd.
Measurement Assistance Center
9-1, Takakura-Cho, Hachioji-Shi,
Tokyo 192, Japan
Tel: (81-426) 56-7832
Fax: (81-426) 56-7840
Latin America:
Hewlett-Packard
Latin American Region Headquarters
5200 Blue Lagoon Drive
9th Floor
Miami, Florida 33126
U.S.A.
(305) 267 4245/4220
Australia/New Zealand:
Hewlett-Packard Australia Ltd.
31-41 Joseph Street
Blackburn, Victoria 3130
Australia
1 800 629 485
Asia Pacific:
Hewlett-Packard Asia Pacific Ltd
17-21/F Shell Tower, Times Square,
1 Matheson Street, Causeway Bay,
Hong Kong
Fax: (852) 2506 9285