how to find us our boiler program for oil and gas
TRANSCRIPT
Our boiler program for oil and gasCondensing boiler technologyLow-temperature technologyStorageAccessories
Intercal Wärmetechnik GmbHIm Seelenkamp 30 32791 Lage · GermanyTelephone +49 (0)5232 60 02-0Fax +49 (0)5232 60 [email protected] · www.intercal.de
From the region From far away
How to find us
09/2
012
Kes
sel L
eh 1
000
Intercal Heat Technology – simply good.
Your heating specialist would be happy to assist you:
Affordable quality products for Germany and beyond
Our boiler program for oil and gasCustomized state-of-the-art heating technology
We ensure future-proof heating.
Intercal Wärmetechnik GmbH has been an established name in affordable quality heating products for over four decades in Germany and beyond. As part of the finan-cially strong MHG Group, we stand for the very highest degree of reliability, sustainability and future proofness. At our company headquarters in the town of Lage in eastern Westphalia, we produce and sell our heating systems and components to more than 25 countries and have established an excellent reputation among our customer base throughout all of the markets we serve. Some one million burners sold as well as our longstanding business relations to renowned heating technology providers bears impressive witness to this.
Partnership and customer proximity have highest priority at Intercal.
Our state-of-the-art logistics center at our compa-ny headquarters in the Westphalian town of Lage ensures flexible and customer-oriented production as well as reliable and prompt deliveries.
Partnership and customer proximity are values that are truly lived out at Intercal Wärmetechnik GmbH. This starts with a personal and individual consultation directly with the Intercal team. In addition, our technical experts intensely train our customers in how to suc-cessfully market and work with our quality products. Our 6,500 m2 site in the city of Lage offers the very latest state-of-the-art infrastructure. This ensures short paths - a decisive factor for the nationally and internationally esteemed Intercal quality. In short: Intercal is simply good.
Oil and gas condensing boiler technologyECOHEAT OIL Floor-standing oil-fired condensing boiler (15 to 40 kW)
ECOHEAT Gas ProKondens Wall-mounted gas-fired condensing boiler (3.5 to 30 kW)
Oil and gas-fired low temperature boiler technologyRATIOLINE R Floor-standing oil unit (18 to 30 kW)
EUROLINE E Floor-standing cast-iron boiler for oil and gas (16 to 69 kW)
EUROLINE E2 Floor-standing cast-iron boiler for oil and gas (70 to 150 kW)
Drinking water storageHorizontal, floor-standing, high-performance and solar storage from 115 to 500 l)
Our program also includes:Air/water heat pumps modulating (3.5 to 15.3 kW) Oil-fired condensing/heat pump hybrid systems (15 kW)Oil burners (12 to 740 kW)Gas burners (14 to 715 kW)Solar heating systems (flat-plate collector complete system) 32
4 5
400 / 450358
780
Technical data
Included in delivery
Wall-mounted gas-fired condensing boiler ECOHEAT Gas ProKondens
Digital 2-channel timer External sensor Storage sensor (for HS models)
Wall bracket
High performance in the smallest spaces
Highly efficient wall-mounted gas-fired condensing boiler available in four compact models (H = heater only/HS = device with 3-way switching valve to com-bine an external storage tank/S = combination device with flow heater)
Available in 15, 25 and 30 kW Highest efficiency for maximum heating cost savings, e.g. through broad modulation range
Aluminum-radial heat exchanger for high energy efficiency
High operating safety and long service life through the use of proven quality components
High user comfort with integrated weather control and digital 2-channel timer
ECOHEAT Gas ProKondens Modulating gas-fired condensing boiler (3.5–30 kW)
Gas condensing boiler technology
Technical data
Saving energy can be this easy
Highly efficient oil condensing boiler with five differ-ent capacities, with low-emission blue-flame burner (BNR) and ECODENS high-performance flue gas heat exchanger made of corrosion-resistance stain-less steel
Standard efficiency up to 103.9 % = maximum heat-ing cost savings
High operating safety and long service life through the use of only proven quality components, e.g. the cast iron unit boiler made of GG 20 with a five-year guarantee
Extremely quiet through its fully encapsulated clad-ding
Individual adjustment with the module system for hydraulic and control components
Time and cost savings with fully preassembled, turn-key device
Oil condensing boiler technology
ECOHEAT OIL Oil-fired condensing boiler (15–40 kW)
ECOHEAT OIL "Basis"Basic boiler, warm pre-set blue flame burner, basic control panel - prepared for the controls of the THETA series (optional), neutraliza-tion unit, 1x supply and 1x return connection for external pump group (optional integration of storage load set)
ECOHEAT OIL "Medium"like the "Basis" model with additionally: integrated and preas-sembled hydraulic group for a direct heating circuit with 3-stage pump, oil two-pipe filter with automatic exhaust for easy assembly to back of boiler, 5-way part for collective return, digital controls THETA 2 B for the control of a direct circuit and a process water circuit (optional integration of storage load set)
ECOHEAT OIL "Premium"like the "Medium" model with additionally: integrated and preassembled hydraulic group for a mixing circuit with 3 stage pump, 1x mixer, 1x actuator and digital controls THETA 23 B for the activation of a mixed and direct circuit as well as a process water circuit (optional integration of storage load set)
VL
RL
537 1018–1168822-972
910
770
540
300
Front view Side view
Customized variety
MODEL ECOHEAT Gas ProKondens H 15
ECOHEAT Gas ProKondens HS 15
ECOHEAT Gas ProKondens HS 25
ECOHEAT Gas ProKondens S 30
Product ID CE 0694 BR 1207Weight (incl. packaging) kg 37 38 39 43Water heating no* External storage Flow heater3-way switching valve no yesDiaphragm-type expansion tank optional 8 l optional 10 l 10 lHydraulic connection diagram StandardDimensions (H × W × D) mm 780 x 400 x 358 780 x 450 x 358Air supply-flue gas outlet mm 60/100, after boiler connection set 80/125Nominal heat input kW 3.5–15.0 6.0–25.0 7.0–30.0Nominal heat output at 80/60 °C kW 3.4–14.5 6.8–24.3 6.8–29.0Nominal heat output at 50/30 °C kW 3.8–15.7 7.4–26.3 7.4–31.4Efficiency at 80/60 °C % 97.2–96.9 97.4–97.2 97.3–96.7Efficiency at 50/30 °C % 108.6–104.9 106.0–105.9 106.4–105.0 105.3–104.8Hot drinking water capacity kW – 7.0–33.0Nominal heat output hot drinking water kW – 7.0–30.0Constant secondary hot water power at ΔT = 30K l/min – 15.8max. hot drinking water temperature °C – 35–60max. flow temperature °C 90max. gas supply pressure mbar 60Electrical connection V/Hz 230/50Permissible flue gas connection types B23, B52, C13X, C33X, C43X, C53X, C63X, C83Xmax. discharge pressure at flue gas outlet Pa 100 120 165Flue gas temperature 80/60 °C, min./max. °C 61/67 61/82 61/80CO2 content (natural gas) Vol. % approx. 9.0Flue gas mass flow (min.–max.) kg/s 0.0016–0.0068 0.0027–0.0115 0.0032–0.0144CO2 content (LPG) Vol. % approx. 10.0Flue gas mass flow (min.–max.) kg/s 0.0017–0.0071 0.0029–0.0118 0.0033–0.0141
Technical changes reserved. * external 3-way switching valve
ECOHEAT OIL MODEL 15 20 25 30 40Product ID CE 0032 BQ KD 1880 CE 0035 BS 103Nominal thermal output kW 15 20 25 30 40Nominal heat input kW 15 20 25 30 40Flue gas temperature (60 °C return temperature) °C 60 63 66 69 68Flue mass flow kg/h 24.1 31.8 39.5 47.7 63.2Flue gas resistance mbar 0.12 0.18 0.35 0.40* 0.50*Maximum discharge pressure mbar 0.65 0.62 0.45 0.60* 0.45*Flue gas connection mm Ø 125/80 Ø 80Standard efficiency (max.) % 103.9CO2 % 13Boiler weight kg max. 155 175 185
Technical changes reserved. * Use flue gas-basis-set DN 100 (item no.: 20.135.2216)
6 7
Technical data
Our All-Rounder Floor-standing boiler unit, standard without burner For energy-saving, environmentally friendly opera-tion, ideal to combine with the Intercal oil and gas burners SLV B, BNR and SGN
Long service life with cast iron unit boiler made of GG 20
Integrated boiler basic control panel, modularly extendable (THETA series)
Preassembled boiler cladding and insulation Compact, space-saving design Extensive accessories freely definable in line with modular principle
EUROLINE E Boiler for oil and gas (16–69 kW)
Low-temperature technology
Technical data
The affordable basic quality Floor-standing oil burner-boiler unit, standard equipped with proven yellow flame burner SLV 100 B
High degree of operational safety and long service life e.g. with the cast iron unit boiler made of GG 20
Further optimized energy efficiency and environmen-tal friendliness by the optional blue flame burner from the BNR series
Integrated boiler basic control panel, modularly extendable (THETA series)
Preassembled boiler cladding and insulation Compact, space-saving design Extensive accessories freely definable in line with modular principle
RATIOLINE R Oil unit (18–30 kW)
Low-temperature technology
Side view Back view
450
850
646
527
116
Vorlauf
Rücklauf
465 (R18+R22) 555 (R26+R30)ca. 300
290
120
520
700
850
130 / 150
V 1 1/4”
R 1 1/4”
530ca. 300
Side view Back view
EUROLINE E E18 E 24 E 28 E 32 E 37 E 42 E 48 E 53 E 58 E 65Number of units Piece 3 4 5 6 7Nominal thermal output kW 16–20 21–26 26–30 30–34 35–39 40–44 46–50 50–56 55–61 59–69Nominal heat input kW 17–21 22–28 28–32 32–37 37–43 43–48 50–54 54–61 60–66 64–74Weight kg 180 225 255 290 325Water content l 20 24 29 34 38Total overpressure max. bar 4
Flue mass flow kg/hHeating oil 30–37 37–46 49–56 55–64 64–73 69–83 81–92 90–105 103–114 111–135Natural gas 27–33 33–40 40–47 45–53 52–61 56–69 67–76 74–87 88–95 91–111
Flue gas temperature at 80°C °C 160 165Discharge pressure required mbar -0.02 -0.03 -0.05 -0.07 -0.09 -0.11 -0.14 -0.17 -0.21CO2 % 12.5Flue gas resistance mbar 0.02 0.03 0.05 0.07 0.09 0.11 0.14 0.17 0.21Wirbulator mm 2x200 2x300 none 4x200 none 2x200, 2x300 none 4x300 2x200, 2x300 4x200, 2x300Measurement A in sketch mm 590 690 790 890 990
Technical changes reserved.
RATIOLINE R (S) 3/18 3/22 4/26 4/30Product ID CE 0032 BM KD 1320Number of elements 3 4Nominal thermal output kW 18.0 22.0 26.0 30.0Nominal heat input kW 19.5 23.6 28.0 32.4Efficiency % 93.8 92.3 94.0 92.8Flue gas temperature °C 150 170 150 170Flue gas value if oil fired kg/h 31 38 45 52Discharge pressure required mbar 0.03 0.05
Burning chamber dimensionsLength mm 365 455
Diameter mm 275 275Burning chamber volume l 21.4 27.3Flue gas connection mm 130Water content l 14.5 17.5Water-side pressure lost for DT = 15 °C mbar 9 16Hydraulic connection ” 1“ 1/4Max. operating pressure bar 4Test pressure bar 8
Technical changes reserved.
8 9
Technical data
Drinking water storage
Customized warm water comfort
Versatile drinking water storage, bottom or side model, optimal for use with various Intercal boilers
Individually adjustable volumes for use as process water or as solar storage
Extremely durable with enameling and integrated corrosion protection
State-of-the-art insulation for energy-saving operation Quick and comfortable warm water supply with high-performance heat transfer
Extensive accessories for an exact fit to heating and control systems
Technical data
Our all-rounder for high- performance requirements
Floor-standing boiler unit, standard without burner For energy-saving, environmentally friendly opera-tion, ideal to combine with the Intercal oil and gas burners SL,SLV and SGN
Long service life with cast iron unit boiler made of GG 20
Integrated boiler basic control panel, modularly extendable (THETA series)
Boiler block also available disassembled in units Available for single- and dual-stage operation
EUROLINE E2 Boiler for oil and gas (70–-150 kW)
Low-temperature technology
EUROLINE E2 MODEL E2-80 E2-100 E2-120 E2-140Number of units 7 8 9 10Nominal thermal output kW 70–90 90–110 110–130 130–150Nominal heat input kW 75–98 98–120 120–142 142–164Weight kg 465 520 575 630Water content l 77 87 98 108Total overpressure max. bar 5
Flue mass flow kg/hHeating oil 117–153 151–187 185–221 218–255Natural gas 114–148 146–181 179–214 212–247
Flue gas temperature °C 140–180Discharge pressure required mbar 0.05–0.07 0.07–0.09 0.09–0.11 0.11–0.13CO2 % 12.5Flue gas resistance mbar 0.15 0.28 0.30 0.40Measurement A in sketch (length) mm 1005 1130 1250 1370
Technical changes reserved.
Model Model SPR 300 SPR 400 SPR 500 SSR 150 SSR 200 SSR 300 TS 150 TS 200 HS 115Process water content l 300 400 500 150 200 300 150 200 115Weight kg 131 158 172 90 130 150 101 130 86WW continuous output 70/45° * l/h 782 957 1087 608 677 910 642 598 745Permissible total overpressure bar 10 6Heat exchanger surface (top/bottom)* m² 0.93/1.40 0.93/1.76 0.96/1.95 0.95 1.30 1.70 0.93 1.00 1.2Power factor (top/bottom)* NL 1.8/7.5 3/11 3.7/15 3 4.5 7.5 2.5 4 1.7
Technical changes reserved. * The information applies to the larger heating pipe (only with SPR) with a flow temperature of 70 °C and 3 m³ flow quantity of heating medium. The cold water supply temperature was 10 °C. The warm water return temperature was 45 °C.
A
1100
868
691
98
668
Side view Back view
Vertical storage(SSR 150 - SSR 200 - SSR 300)
Horizontal storage(TS 150 - TS 200)
500-530 (je nach Ausführung)
890
10
G 1
/2”
46
20
180 (Öffnung)
High-performance storage HS 115 (wall-mounted or floor-standing)
520
530
140 120
5050
130
140
140
170
500
Solar storage (SPR 300 - SPR 400 - SPR 500)
305-
370
983-
1095
1507
-149
6
1790
-185
3
Einschraub-Heizungsmufe
Warmwasser -Ablauf
ThermometerMagnesiumanode
Heizkreis-Vorlauf 1”
Heizkreis-Rücklauf 1”
ZirkulationAG
Heizkreis- Vorlauf 1”
Heizkreis-Rücklauf 1”
263-
370
836-
930 96
3-10
95 1083
-1195 14
43-1
465
610-760
85
Kaltwasser-Zulauf 1”
Verstellfuß mitFußaufnahme
Horizontal, floor-standing, high-performance and solar storage (115–500 l)
10 11
Boiler Accessories
Versatility for all demandsIn connection with our condensing boiler and low-temperature program we off extensive and precisely coordinated accessories for virtually any situation.
The controls of the THETA series are particularly distin-guished by their extreme user friendliness. The heating system can be configured to the needs of the operator in just a few simple steps. A plain-text menu guides the operator through the entire process.The THETA series can also realize complex control requirements.
By combining the controls of the THETA series with the illuminated remote controls of THETA RSL, you can query the operating status of your boiler with a practical remote control and comfortably configure your room settings and virtually all other parameters. THETA RSL is connected via a twin-axial cable (two-wire bus).
The Intercal heating circuit pump groups with and wit-hout mixers – consisting of top-grade brass parts and brand components (pump, actuator) – are the optimal supplements for any boiler. The optional system acces-sories (e.g. connection pipework and distributor bars) can be easily adapted to any heating system.
The entire system from one source – various hydraulics groups for virtually all system requirements consist of the very highest quality components. Our product range provides solutions for safety groups, storage supply pump sets for horizontal and floor-standing storages as well as several other connections solutions.
With the optional flue gas sound absorbers made of stainless steel, Intercal boilers are also very suitable for difficult installation situations within living quarters. Its patented T-shaped design makes it an excellent solution for very small boilers rooms.
We also offer further accessories such as diaphragm-type expansion tanks, sound cabinets, fixed bases (boiler base), storage thermometers and digital room thermometers.
The Intercal ECODENS stainless steel flue gas heat exchanger is the simple and energy-efficient solution for any oil or gas heating system (also very suitable for re-trofitting). For instance, our blue-flame burner from the BNR series turns any boiler into an efficient condensing heat system.
From the basement to the roof – for our condensing boiler systems ECOHEAT Oil, ECOHEAT plus and the ECODENS stainless steel flue gas heat exchangers, we offer complete flue gas systems made of plastic. This facilitates easy and quick installation and it is also a cost-effective solution for the renovation of flue gas systems.
The wall-mounted case THETA MSK is used for expan-ding a control system or retrofitting an existing heating system. This case can accommodate THETA controls up to the maximum configuration (THETA 2233 BVV). All ultimate consumers (pumps, mixers, etc.) can be connection without any additional wiring required.