how to calibrate precitec height sense unit

Download How to calibrate  Precitec  Height sense unit

If you can't read please download the document

Upload: anil-kushwaha

Post on 07-Jan-2016

579 views

Category:

Documents


29 download

DESCRIPTION

Precitec EG8050 unit

TRANSCRIPT

Sheet1Tip touch value in B 8How to calibrate nozzle after change new ceramic.Tip touch85.641- open electric cabinet.11075.642- Press the knob & enter the password (7657) on EG8030.2877.643- Go to config 1 menu3778.644- Choaae PA Selct & press Enter.( know you can see * sign before PA SELECT)4679.645- Press knob5580.646-find Char-Cal & enter6481.648- follow the instruction TIP Touch Value B 87382.6482.583.149- after doing this you will fin OK on EG8030, it mean calibration is succesful.9283.6410- After calibration again go in config1101.883.8411- select PA Selct & press enter ( now you can see no * sign is before PA Selct.)111.584.1412- Press knob & come out.121.284.4413184.64140.784.94150.585.14160.285.44