house as a system
DESCRIPTION
House as a System. QUALITY CONTROL INSPECTOR. WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012. Learning Objectives. House as a system. By attending this session, participants will be able to: - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/1.jpg)
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
House as a SystemQUALITY CONTROL INSPECTOR
WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012
![Page 2: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/2.jpg)
2 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
By attending this session, participants will be able to:• Discuss the potential for interaction among building
components and mechanical systems.
• Give examples of how air sealing a home can negatively affect building durability and indoor air quality.
• Recognize typical air leakage sites and explain how to deal with them.
Learning ObjectivesHOUSE AS A SYSTEM
![Page 3: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/3.jpg)
3 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
A house is a system of interdependent parts.• The operation of one part affects many others.
• When they all work together, the house is comfortable, safe, efficient, and durable.
A house will experience problems when its house parts don’t work together properly.
• Some obvious, some invisible
• Some now, some years down the road
House as a SystemHOUSE AS A SYSTEM
![Page 4: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/4.jpg)
4 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
House as a System
HOUSE AS A SYSTEM
Diagram courtesy of John Tooley
![Page 5: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/5.jpg)
5 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Examples – House as a System
An uninsulated attic... …makes the heating and cooling system work harder than necessary.
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 6: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/6.jpg)
6 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Examples – House as a System
Leaky recessed lighting fixtures...
…increases heat loss/gain,
and can cause ice dams.
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 7: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/7.jpg)
7 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Examples – House as a System
This bathroom exhaustfan does not exhaust to
outdoors–just to the soffit.
The moisture condenses on the roof deck and
trusses causing damage.
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 8: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/8.jpg)
8 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Ventilation & Air Change
Why seal the leaks at all?
HOUSE AS A SYSTEM
Image created for the US DOE WAP National Standardized Curriculum
![Page 9: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/9.jpg)
9 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
• 2 in. x 6 in. rafters with plywood decking
• White “dots” are frost on nail points
In the Attic…HOUSE AS A SYSTEM
Photo courtesy of The US Department of Energy
![Page 10: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/10.jpg)
10 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Plumbing pipe and dirty insulation are clues…
…that an attic bypass is allowing air flow through
the insulation.
Photos courtesy of The US Department of Energy
![Page 11: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/11.jpg)
11 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Chimney ChasesHOUSE AS A SYSTEM
Photo courtesy of The US Department of Energy
![Page 12: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/12.jpg)
12 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Treating the Chimney ChaseHOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 13: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/13.jpg)
13 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Sealed Chimney Bypass
Sealed chimney bypass…
…with insulation barrier.
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 14: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/14.jpg)
14 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
An Alternative Method
Detail for Sealing Thermal Bypass Around Chimney
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 15: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/15.jpg)
15 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
In the Basement
Spauling on cement blocks
Spauling
Minor mold on floor stringers
Mold on cement blocks
High standing water
High water mark
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 16: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/16.jpg)
16 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Plumbing and Wire OpeningHOUSE AS A SYSTEM
Photo courtesy of The US Department of Energy
![Page 17: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/17.jpg)
17 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Under the TubHOUSE AS A SYSTEM
Photo courtesy of The US Department of Energy
![Page 18: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/18.jpg)
18 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Another TubHOUSE AS A SYSTEM
Photo courtesy of The US Department of Energy
![Page 19: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/19.jpg)
19 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
More in the Basement
Top of connection between heat delivery plenum and main trunk
HOUSE AS A SYSTEM
Photo courtesy of The US Department of Energy
![Page 20: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/20.jpg)
20 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Danger!
More in the Basement
Grille cut into return plenum sucks on barometric damper
Thermocouples shut off flame when backdrafting occurs, but real culprit is leaky return ductwork on furnace (not shown).
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 21: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/21.jpg)
21 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
In the GarageHOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 22: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/22.jpg)
22 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
In the Kitchen and BathroomHOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 23: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/23.jpg)
23 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Dropped Soffits
Kitchen wall cabinets mounted
under soffit or valance
HOUSE AS A SYSTEM
Image created for the US DOE WAP National Standardized Curriculum
![Page 24: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/24.jpg)
24 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Dropped Soffits
If you see soffit-mounted cabinets,
remember to investigate during
attic inspection.
HOUSE AS A SYSTEM
Image created for the US DOE WAP National Standardized Curriculum
![Page 25: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/25.jpg)
25 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Fireplaces “net cool” all but the smallest spaces.
In the Living RoomHOUSE AS A SYSTEM
Photo courtesy of The US Department of Energy
![Page 26: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/26.jpg)
26 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Then there are
vent-free fireplaces,
kerosene heaters,
and homemade stuff.
Unvented Space HeatersHOUSE AS A SYSTEM
Photo courtesy of The US Department of Energy
![Page 27: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/27.jpg)
27 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Outside
Trees and bushes against a building prevent wall
assemblies from drying.
Cathedral ceilings invite moisture and mold problems.
Roof windows or recessed lights will further complicate matters.
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 28: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/28.jpg)
28 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
All exhaust appliances “suck” on the house.
Mechanical VentilationHOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 29: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/29.jpg)
29 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Occupant BehaviorHOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 30: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/30.jpg)
30 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
What’s Going On?
Heavy condensation on center window. No condensation on side windows.
Why? What is the most likely moisture source?
HOUSE AS A SYSTEM
Photo courtesy of The US Department of Energy
![Page 31: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/31.jpg)
31 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
What Should Be Done?
• Add a storm window.
• Replace the entire window unit.
• Advise the homeowner to run the ceiling fan.
• Get rid of the plants.
It Depends!
HOUSE AS A SYSTEM
Photo courtesy of The US Department of Energy
![Page 32: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/32.jpg)
32 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Something to Think About
Houses:• Are tighter.
• Have more exhaust appliances.
• Have “weaker” natural draft combustion appliances.
• Have less drying potential.
Diagram courtesy of John Tooley
HOUSE AS A SYSTEM
![Page 33: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/33.jpg)
33 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Today’s Houses Are Tighter
OldBoarded exterior with lath & plaster interior walls
NewPlywood & drywall
HOUSE AS A SYSTEM
Images created for the DOE WAP National Standardized Curriculum
![Page 34: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/34.jpg)
34 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Today’s Houses Have More and Bigger Fans
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 35: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/35.jpg)
35 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
System 2000™ 90+% High Mass drybase boiler 80% Converted coal boiler 50%
Air Tight Wood StoveKuma Stoves kumastoves.com
Today’s Houses Have Weaker Draft Appliances
Glass doors reduce air lossOpen fireplaces
The weaker the draft (i.e., the higher the efficiency), the less air moves through the heating system & therefore the house.
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 36: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/36.jpg)
36 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Older Home:• Balloon-framed two-story
home (lots of stack effect).• Boards, plaster & lathe.• No insulation.• Construction style and
materials inherently leaky.
Today’s Houses Have Less Drying Potential
The new house gets just as wet but can’t dry; therefore poor IAQ and mold/mildew.
Newer Home:• Low (little stack effect).• Plywood & drywall.• Construction style and materials
inherently tighter than older home.
The old house got wet in the summer (humid) & dried in the winter (low humidity).
HOUSE AS A SYSTEM
Photos courtesy of The US Department of Energy
![Page 37: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/37.jpg)
37 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
Lifestyle ChangesHOUSE AS A SYSTEM
![Page 38: House as a System](https://reader036.vdocuments.us/reader036/viewer/2022070423/5681678d550346895ddcafe6/html5/thumbnails/38.jpg)
38 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – September 2012 eere.energy.gov
• We build very differently than we did 40 years ago.
• Economic pressure is driving the move to tighter houses with smaller margins of safety.
• The tighter a house is, the more influence individual components have on the others.
• All pollutants inside the pressure boundary will eventually be dispersed over the entire area.
• Altering a building or its mechanicals can have unexpected consequences.
Summary
HOUSE AS A SYSTEM