honeywell xls 80e 2 to 8 loop intelligent control panel
DESCRIPTION
Honeywell XLS 80e 2 to 8 Loop Intelligent Control Panel. XLS80e 2 to 8 Loop Intelligent Control Panel. XLS80e Intelligent Repeater Panel. XLS80e - Network. Peer-to-peer network ArcNet based Re-transmission and isolation between nodes (1 km btw. nodes) - PowerPoint PPT PresentationTRANSCRIPT
Excel Excel Life SafetyLife Safety
HoneywellHoneywellXLS 80e XLS 80e
2 to 8 Loop Intelligent Control Panel2 to 8 Loop Intelligent Control Panel
Excel Excel Life SafetyLife Safety
XLS80eXLS80e2 to 8 Loop Intelligent Control Panel2 to 8 Loop Intelligent Control Panel
Excel Excel Life SafetyLife Safety
XLS80eXLS80eIntelligent Repeater PanelIntelligent Repeater Panel
4
Excel Excel Life SafetyLife Safety
XLS80eXLS80e - Network - Network
• Peer-to-peer networkPeer-to-peer network– ArcNet basedArcNet based– Re-transmission and isolation between nodes Re-transmission and isolation between nodes
(1 km btw. nodes)(1 km btw. nodes)– Error checking and correctionError checking and correction
at each nodeat each node– Message routingMessage routing– Up to 100 network nodesUp to 100 network nodes– Up to 158,400 devicesUp to 158,400 devices– Up to 25,500 zonesUp to 25,500 zones– Up to 700A PSUUp to 700A PSU– Network alarm response less than 10 Network alarm response less than 10
secondsseconds
5
Excel Excel Life SafetyLife Safety
Master/Slave or “Peer to Peer”Master/Slave or “Peer to Peer”
BREAK GLASS
PRESS HERE
DOORHOLDER
DUCTHOUSING
AND SENSOR
ISOLATORMODULE
ISOLATORMODULE
MCP
THERMALSENSOR
LOOP-POWEREDSOUNDER
EXTERNALLYPOWEREDSOUNDER
LOOP-POWEREDBASE SOUNDER
THERMALSENSOR
PHOTOSENSOR
IONISATIONSENSOR
CONTROLMODULE
CONTROLRELAY MODULE
CONVENTIONAL ZONE
CONVENTIONALDETECTORINTERFACE
MODULE
CONVENTIONALDEVICES
BEAMDETECTOR
BREAK GLASS
PRESS HERE
MCP
6
Excel Excel Life SafetyLife Safety
Life Safety System GoalsLife Safety System Goals
• Greater fire detection accuracy with Greater fire detection accuracy with elimination of nuisance alarmselimination of nuisance alarms
• Faster responseFaster response
• Greater flexibility in alarm system Greater flexibility in alarm system design and applicationdesign and application
• Lower installed costLower installed cost
• Lower operating and maintenance costLower operating and maintenance cost
7
Excel Excel Life SafetyLife Safety
Global Market OfferingGlobal Market Offering
• Compliant with EN54Compliant with EN54• Large graphLarge graphiic LCDc LCD
• Multi-lingual capabilityMulti-lingual capability
• Modular designModular design
• Site configurableSite configurable
• Application software flexibilityApplication software flexibility
8
Excel Excel Life SafetyLife Safety
XLS80e Applications (1)XLS80e Applications (1)
An advanced life safety system designed for large single site An advanced life safety system designed for large single site and multi-site applications and multi-site applications
• Office towersOffice towers
• AirportsAirports
• HospitalsHospitals
• UniversitiesUniversities
• Manufacturing Manufacturing complexescomplexes
• Military basesMilitary bases
• Government buildingsGovernment buildings
9
Excel Excel Life SafetyLife Safety
XLS80e Applications (2)XLS80e Applications (2)
• Retrofit and new constructionRetrofit and new construction
• Medium to large multiple Medium to large multiple building systemsbuilding systems
• Standalone systemsStandalone systems
• Networked systemsNetworked systems
10
Excel Excel Life SafetyLife Safety
ID3000 Technical AdvancesID3000 Technical Advances
• Modular designModular design
• Surface mount technologySurface mount technology
• Fully automated test equipmentFully automated test equipment
• User friendly interfaceUser friendly interface
• Peripheral optionsPeripheral options
• Advanced software featuresAdvanced software features
• Easy programmingEasy programming
• Multiple language optionsMultiple language options
11
Excel Excel Life SafetyLife Safety
Traditional Fire Alarm FunctionsTraditional Fire Alarm Functions
• Smoke and fire detectionSmoke and fire detection
• Sprinkler system supervisionSprinkler system supervision
• Automatic and manual system operationAutomatic and manual system operation
Added Value OptionsAdded Value Options
• Advanced detection productsAdvanced detection products
– Filtrex™, Multi-criteria, loop powered sounders and beam Filtrex™, Multi-criteria, loop powered sounders and beam detectorsdetectors
• Enhanced loop interface board (E-LIB)Enhanced loop interface board (E-LIB)
• Active and passive repeatersActive and passive repeaters
• Graphic annunciator driverGraphic annunciator driver
12
Excel Excel Life SafetyLife Safety
Key TermsKey Terms
• Basic Equipment Kit Basic Equipment Kit
• Extension Chassis KitExtension Chassis Kit
• LIB - Loop Interface BoardLIB - Loop Interface Board
• E-LIB - Enhanced Loop I/F BoardE-LIB - Enhanced Loop I/F Board
• DTP - Dual Transmission Path Booster I/F KitDTP - Dual Transmission Path Booster I/F Kit
• PSU - Power Supply UnitPSU - Power Supply Unit
• Node - A system panel in a networkNode - A system panel in a network
• LCD - Liquid Crystal Display LCD - Liquid Crystal Display
• CBE - Control by Event MatrixCBE - Control by Event Matrix
• Mimic (Graphic Annuciator) Driver KitMimic (Graphic Annuciator) Driver Kit
Excel Excel Life SafetyLife Safety
Hardware OverviewHardware Overview
14
Excel Excel Life SafetyLife Safety
Modular DesignModular Design
Basic Configuration
BasicEquipment Kit
Installation/Commissioning Kit
Cover(s)
Backbox(es)
Extension Chassis(if required)
Optional ExpansionModules (if required) Power Supply
15
Excel Excel Life SafetyLife Safety
ID3000 Key ComponentsID3000 Key Components
Backbox Power Supply Basic Equipment Kit Covers & Batteries & Extension Chassis
16
Excel Excel Life SafetyLife Safety
Modular DesignModular Design
• Modular design offers:Modular design offers:
– flexibilityflexibility
– ease of expansionease of expansion
– lower service costlower service cost
17
Excel Excel Life SafetyLife Safety
Basic Equipment KitBasic Equipment Kit
ProcessorPCB
Display PCB
Base Card
Main Chassis
Expansion Cards
18
Excel Excel Life SafetyLife Safety
Basic Equipment KitBasic Equipment Kit
• Can be extended with:Can be extended with:
– Up to 3 Standard Loop Cards (LIB)Up to 3 Standard Loop Cards (LIB)
– Up to 3 Enhanced Loop Cards (E-LIB) Up to 3 Enhanced Loop Cards (E-LIB)
– One RS-232 CardOne RS-232 Card
– One RS-485 CardOne RS-485 Card
– One ID-Net Card (*)One ID-Net Card (*)
– Panel PrinterPanel Printer
19
Excel Excel Life SafetyLife Safety
Basic Equipment KitBasic Equipment Kit
20
Excel Excel Life SafetyLife Safety
BEK - Inputs & OutputsBEK - Inputs & Outputs
• Outputs:Outputs:
– A/B/C/D - Sounder or Relay programmableA/B/C/D - Sounder or Relay programmable
• Sounder - rated @ 1A/30V eachSounder - rated @ 1A/30V each
• Dry contact relay - rated @ 1A/30VDry contact relay - rated @ 1A/30V
• Two can be programmed for German UE interfaceTwo can be programmed for German UE interface
– Fault and Fire RelaysFault and Fire Relays
• rated @ 1A/30V eachrated @ 1A/30V each
– Auxiliary 26-28Vdc outputs 1 and 2Auxiliary 26-28Vdc outputs 1 and 2
• both rated @ 1Aboth rated @ 1A
– Battery charger max. 8.6A (130Ah batteries)Battery charger max. 8.6A (130Ah batteries)
21
Excel Excel Life SafetyLife Safety
BEK - Inputs & OutputsBEK - Inputs & Outputs
• Inputs:Inputs:
– Mains - 230Vac ± 15% 50/60 HzMains - 230Vac ± 15% 50/60 Hz
– Two addressable loops - 500mATwo addressable loops - 500mA
– Tamper switch input (VF dry contact)Tamper switch input (VF dry contact)
• Serial Ports:Serial Ports:
– RS232 Port 1RS232 Port 1
• PC Programming, internal printer optionPC Programming, internal printer option
– RS232 Port 2 (optional module)RS232 Port 2 (optional module)
– RS485 Port (optional module)RS485 Port (optional module)
22
Excel Excel Life SafetyLife Safety
Modular DesignModular Design
Extension Chassis Options
Double Extension Chassis with 255 Zone Display
Module Kit
Extension Chassis with PRN2000
Printer Module Kit
Extension Chassis with 64 Zone Display
Module Kit (with or without Printer)
Extension Cover Blanking Plate
23
Excel Excel Life SafetyLife Safety
Extension OptionsExtension Options
64/128 Zone LED’s and Panel Printer
255 Zone LED’s External Printer Support
ExtendedBackbox
24
Excel Excel Life SafetyLife Safety
Modular DesignModular Design
Optional Expansion Modules
Dual LoopModule Kit
Isolated RS232Module Kit
Isolated RS485Module Kit
Printer Module Kit ID-Net
Network Card
Enhanced Dual Loop Module Kit
25
Excel Excel Life SafetyLife Safety
Standard LIB v’s. E-LIBStandard LIB v’s. E-LIB
• LIBLIB– Handles communication onlyHandles communication only
– System CPU scans loopsSystem CPU scans loops• In case of main CPU failure In case of main CPU failure
all detection is lostall detection is lost
– CPU always busyCPU always busy
– Max. 512 devices per panelMax. 512 devices per panel
• E-LIBE-LIB– Powerful microprocessorPowerful microprocessor
– Degrade modeDegrade mode• In case of main CPU failure the E-LIB In case of main CPU failure the E-LIB
will still activate sounder circuits 1-4 and will still activate sounder circuits 1-4 and the Fire Relay when an alarm is received the Fire Relay when an alarm is received from the loopfrom the loop
– CPU available for other tasksCPU available for other tasks
– Full device count on the Full device count on the panelpanel
26
Excel Excel Life SafetyLife Safety
Serial CommunicationSerial Communication
• RS232 OptionRS232 Option
– Isolated portIsolated port
– Third party interfaceThird party interface
– External printer External printer
– UniNet (NION) connectionUniNet (NION) connection
– Pager interfacePager interface
– VDU for terminal emulationVDU for terminal emulation
• RS485 OptionRS485 Option
– IsolatedIsolated
– Master/Slave networkMaster/Slave network
– Multi-dropMulti-drop
– RepeatersRepeaters
– Graphic annunciatorsGraphic annunciators
27
Excel Excel Life SafetyLife Safety
Expansion ModulesExpansion Modules
28
Excel Excel Life SafetyLife Safety
Modular DesignModular Design
Power Supply SelectionPower Supply Selection
Power Supply Unit KitPower Supply Unit Kit2.5 Amp2.5 Amp
Universal PSU KitUniversal PSU Kit4.5A or 7.0A4.5A or 7.0A
(External enclosure (External enclosure or deep boxes only) or deep boxes only)
PSU DTPPSU DTPBooster KitBooster Kit
(4.5 or 7.0A PSU only)(4.5 or 7.0A PSU only)
Remote Battery/Charger Remote Battery/Charger Enclosure KitEnclosure Kit
29
Excel Excel Life SafetyLife Safety
Power Supply OptionsPower Supply Options
2.5A PSU 2.5A PSU mounts on the mounts on the
side of the side of the BEKBEK
DTP Booster DTP Booster mounts on the mounts on the
side of the side of the BEKBEK
4.5A PSU 4.5A PSU mounts into the mounts into the deep deep ((extended) extended) back boxback box
7A PSU 7A PSU mounts into mounts into the external the external charger/ battery charger/ battery enclosureenclosure
30
Excel Excel Life SafetyLife Safety
PSU with Dual Transmission PSU with Dual Transmission Path Booster KitPath Booster Kit
• Temperature compensated battery chargerTemperature compensated battery charger
• DTP required by EN54-4 for external PSU applicationDTP required by EN54-4 for external PSU application
• Maintains constant loop voltage over a wide range of mains and battery Maintains constant loop voltage over a wide range of mains and battery voltages voltages
• Fault monitoring on the power supply, mains and the batteriesFault monitoring on the power supply, mains and the batteries
• Inhibits charger in case of an alarmInhibits charger in case of an alarm
31
Excel Excel Life SafetyLife Safety
Power Supply OptionsPower Supply Options
PSU SizeTypical number
of loopsAvailable auxiliary
power (Total)Battery Charger
2.5A 4 1A1.9A max.
38Ah Batteries
4.5A 6 2A2.7A max.
42Ah Batteries
7.0A 8 2A8.6A max.
130Ah Batteries
• 7A PSU Status Indication LEDs7A PSU Status Indication LEDs(for use in the Remote Enclosure) (for use in the Remote Enclosure)
32
Excel Excel Life SafetyLife Safety
Modular DesignModular Design
Backbox Options
Standard Back Box Kit
Extended Back Box Kit(available in ‘standard’ and ‘deep’)
Double Extended Backbox Kit(available in ‘standard’ and ‘deep’)
Backbox Extension Kit (available in ‘standard’ and ‘deep’)
Flush Mounting Bezels
33
Excel Excel Life SafetyLife Safety
Back-box OptionsBack-box Options
17Ah 17 Ah
38Ah
12Ah
Standard Extended Double Extended External Box
78Ah38Ah
Standarddepth
Deep Boxes
34
Excel Excel Life SafetyLife Safety
ModularModular Design Design
Cover/Door Kits
Extension Cover Blanking Plate
Double Extension Cover Kit
Extension Cover Kit(High Security option)
Main Cover Kit(High Security option)
Security Door Kits(available for main &
extension covers)
35
Excel Excel Life SafetyLife Safety
Cover OptionsCover Options
• All covers are available in:All covers are available in:
– Black/Grey (standard) - Black/Grey (standard) - matching backbox and bezelmatching backbox and bezel
– Red -Red -matching backbox and bezelmatching backbox and bezel
– NEXTEL Grey - matching bezelNEXTEL Grey - matching bezel
– Stainless Steel- matching bezelStainless Steel- matching bezel
36
Excel Excel Life SafetyLife Safety
19” Rack Mounting Option19” Rack Mounting Option
37
Excel Excel Life SafetyLife Safety
19” Rack Mounting Option19” Rack Mounting Option
• 19” Rack Mounting Assembly for Basic Equipment Kit 19” Rack Mounting Assembly for Basic Equipment Kit
• 6U x 19” Rack Mounting Assembly for 7A PSU6U x 19” Rack Mounting Assembly for 7A PSU
• 6U x 19” Rack Mounting Assembly 6U x 19” Rack Mounting Assembly
for 64 Zone LED Extension Chassis & Printer Kitfor 64 Zone LED Extension Chassis & Printer Kit
• 6U x 19” Rack Mounting Assembly for 256 Zone6U x 19” Rack Mounting Assembly for 256 Zone
LED Extension Chassis KitLED Extension Chassis Kit
• 6U x 19” Rack Mounting Assembly for Printer6U x 19” Rack Mounting Assembly for Printer
• 3U x 19” Rack Blank Cover with Mains Termination Kit3U x 19” Rack Blank Cover with Mains Termination Kit
• 6U x 19” Rack Blank Cover with Mains Termination Kit6U x 19” Rack Blank Cover with Mains Termination Kit
• 3U x 19” Rack Mounting Assembly for Mimic Driver Kit 3U x 19” Rack Mounting Assembly for Mimic Driver Kit
• 6U x 19” Rack Blank Cover6U x 19” Rack Blank Cover
• 3U x 19” Rack Blank Cover3U x 19” Rack Blank Cover
All available in the standard black/grey colourAll available in the standard black/grey colour
38
Excel Excel Life SafetyLife Safety
Take Your Pick!Take Your Pick!
Excel Excel Life SafetyLife Safety
User InterfaceUser Interface
40
Excel Excel Life SafetyLife Safety
6 Line x 40 6 Line x 40 Character Character
Graphic LCDGraphic LCD
Main Main Control Control
SwitchesSwitches
System System Status Status
IndicatorsIndicators
• Navigation Navigation KeypadKeypad
• Numeric Data Numeric Data Entry & Entry &
Enter/Cancel Enter/Cancel
• Key switchKey switchAccess Level 2Access Level 2
Main User InterfaceMain User Interface
41
Excel Excel Life SafetyLife Safety
Main User InterfaceMain User Interface
• Fully EN54 Fully EN54 compliantcompliant
• Simple tabbed menu navigationSimple tabbed menu navigation
• Prioritised event display Prioritised event display ((Automatically displays highest priority event)Automatically displays highest priority event)
• User in control/has choice User in control/has choice of what is displayedof what is displayed
• Simple lights and switches for Simple lights and switches for common controlscommon controls
• Top level info displayedTop level info displayed
42
Excel Excel Life SafetyLife Safety
Graphic DisplayGraphic Display
• Large 240 x 64 pixel LCD Large 240 x 64 pixel LCD 6 lines x40 characters6 lines x40 characters
• Short-cuts for test & disablementShort-cuts for test & disablement
• Selection by direct addressingSelection by direct addressing
• Displays:Displays:
– Time and DateTime and Date
– Active Point Count for each eventActive Point Count for each event
– Event type, index and actions Event type, index and actions
– Panel, Zone and Device descriptorsPanel, Zone and Device descriptors
43
Excel Excel Life SafetyLife Safety
System Information on Windows Style Tabbed ScreensSystem Information on Windows Style Tabbed Screens
Graphic DisplayGraphic Display
44
Excel Excel Life SafetyLife Safety
EVENT TYPES AND EVENT TYPES AND TAB DISPLAY PRIORITIESTAB DISPLAY PRIORITIESHighest Highest
PriorityPriorityLowest Lowest PriorityPriority
If there is insufficient room to display all 8 tabs, then If there is insufficient room to display all 8 tabs, then the lowest (on the right) are omitted.the lowest (on the right) are omitted.
Graphic DGraphic Diisplaysplay
FIRE PRE-A FAULT DISAB TEST EVAC AUX USER
45
Excel Excel Life SafetyLife Safety
Panel and Zone Text up to 32 Characters via KeyboardPanel and Zone Text up to 32 Characters via Keyboard
to Navigate and to Navigate and to Select to Select
Virtual KeyboardVirtual Keyboard
46
Excel Excel Life SafetyLife Safety
ExampleExample -- 3 Zones in Alarm:3 Zones in Alarm: 2 Devices Alarmed in Zone 2 2 Devices Alarmed in Zone 2 1 Device Alarmed in Zone 11 Device Alarmed in Zone 1
1 other zone in Alarm - Press “Zones in Alarm” to view others1 other zone in Alarm - Press “Zones in Alarm” to view others
Use Navigation keys 46 to scroll through zones and display other Use Navigation keys 46 to scroll through zones and display other devices, date/time of event and device % value, etc.devices, date/time of event and device % value, etc.
Short-cut key Short-cut key selects either device or zone disablement. selects either device or zone disablement.
Fire Alarm DisplayFire Alarm Display
47
Excel Excel Life SafetyLife Safety
PRE-ALM DISPLAY REQUIRED?????
FROM P21 OF OPERATING MANUAL
3 Zones are in Pre-Alarm with 4 events in the system3 Zones are in Pre-Alarm with 4 events in the system
2 Pre-Alarms are currently in Zone 8.2 Pre-Alarms are currently in Zone 8.
Use Use to scroll through zones & to scroll through zones &for device selection.for device selection.
Pre-Alarm DisplayPre-Alarm Display
48
Excel Excel Life SafetyLife Safety
Fault DisplayFault Display
3 Zones are in FAULT with 4 events in the system.3 Zones are in FAULT with 4 events in the system.
Use Use to scroll through zones and to scroll through zones and to display device, type, to display device, type, value, etc.value, etc.
49
Excel Excel Life SafetyLife Safety
142 Devices Disabled in 3 input zones. 12 devices are disabled in Zone 2 142 Devices Disabled in 3 input zones. 12 devices are disabled in Zone 2 (all input devices).(all input devices).
No outputs are disabled. Use No outputs are disabled. Use to scroll through zone list and to scroll through zone list and to see to see device details.device details.
Disablement DisplayDisablement Display
ExcelExcel
Life SafetyLife Safety
50
Excel Excel Life SafetyLife Safety
Main Control SwitchesMain Control Switches
Silence Silence Panel Panel
BuzzerBuzzer
Activate 2nd Activate 2nd Stage Delay Stage Delay
(if in Day Mode)(if in Day Mode)
Override Delays Override Delays &&
Operate SoundersOperate Sounders
Silence & Silence & Re-start Re-start
SoundersSoundersPanel Panel ResetReset
Toggle between Day Toggle between Day and Night Modes and Night Modes
(German VdS (German VdS Mode)Mode)
Disable Fire Relay Disable Fire Relay and Fire Output and Fire Output (if Configured)(if Configured)
Show User MenuShow User MenuToggle User MenusToggle User Menus
Accept Non-Fire Accept Non-Fire AlarmAlarm Show Fire Info & Show Fire Info &
Scroll through Zones Scroll through Zones in Firein Fire
Accept Fire AlarmAccept Fire Alarm
51
Excel Excel Life SafetyLife Safety
Fire condition existsFire condition exists
Fault condition existsFault condition exists
Pre-Alarm condition existsPre-Alarm condition exists
System/CPU failureSystem/CPU failure
Sounder O/P fault or disabledSounder O/P fault or disabled
Fire relay disabled, or fire O/P Fire relay disabled, or fire O/P disabled/in faultdisabled/in fault
Fire relay or fire O/P is activeFire relay or fire O/P is active
System Status IndicatorsSystem Status Indicators
52
Excel Excel Life SafetyLife Safety
One or more devices disabledOne or more devices disabled
Test mode active (Walk-Test, etc.)Test mode active (Walk-Test, etc.)
Mains or battery power OKMains or battery power OK
Day mode active (pushbutton Day mode active (pushbutton operated)operated)
Programmed delays enabledProgrammed delays enabled
A Non-Fire (AUX) device activatedA Non-Fire (AUX) device activated
Spare for future featuresSpare for future features
Spare for future featuresSpare for future features
System Status Indicators - 2System Status Indicators - 2
53
Excel Excel Life SafetyLife Safety
Navigation & Numeric KeysNavigation & Numeric Keys
Up (Next)Up (Next)
Left (Back)Left (Back)
Down (Previous)Down (Previous)
Right (Forward)Right (Forward)
Text EditText EditShort-CutsShort-CutsDisable/EnableDisable/EnableMenu SelectMenu Select
Cancel/EscapeCancel/EscapeAcceptAccept/EnterEnter
Numeric Numeric Data Data
EntryEntry
54
Excel Excel Life SafetyLife Safety
64 Zone LED Display Module 64 Zone LED Display Module (Single Extension Chassis) Two (Single Extension Chassis) Two
Variants: Zones 1 to 64 or Zones Variants: Zones 1 to 64 or Zones 65 to 12865 to 128
255 Zone LED 255 Zone LED Display Module Display Module (Double Extension (Double Extension Chassis)Chassis)
Zone Status IndicatorsZone Status Indicators
• FIRE and FAULT/DISABLED/TEST Indication
55
Excel Excel Life SafetyLife Safety
Language OptionsLanguage Options
Easy translation/customisation Easy translation/customisation using “Slide-In” type text labelsusing “Slide-In” type text labels
56
Excel Excel Life SafetyLife Safety
Main FeaturesMain Features
• Approved to EN54 Parts 2 and 4Approved to EN54 Parts 2 and 4• Degraded mode of operationDegraded mode of operation
– Enhanced LIB (parallel CPUs)Enhanced LIB (parallel CPUs)• Support for:Support for:
– Advanced detection devices (VIEW™, HARSH™, Advanced detection devices (VIEW™, HARSH™, MULTI)MULTI)
– Loop powered sounders (ABS4, IBS3, ANS4, Loop powered sounders (ABS4, IBS3, ANS4, AWS3)AWS3)
– Loop powered beam detectors (LPB-500, LPB-Loop powered beam detectors (LPB-500, LPB-620)620)
• Menu driven point/data accessMenu driven point/data access• Multi-level operator password controlMulti-level operator password control• Multiple language optionsMultiple language options
– English, German, Spanish, Icelandic, English, German, Spanish, Icelandic, Dutch/French (*)Dutch/French (*)
57
Excel Excel Life SafetyLife Safety
Key Key FunctionsFunctions
• 10 sensitivity levels for Fire & Pre-alarm10 sensitivity levels for Fire & Pre-alarm
• Adjustable alarm & fault verification delayAdjustable alarm & fault verification delay
• Two-stage alarm operationTwo-stage alarm operation
• Alarm silence/re-soundAlarm silence/re-sound
• Sound general alarm (Evacuate)Sound general alarm (Evacuate)
• Day and Night modesDay and Night modes
• Fire output(s) inhibit Fire output(s) inhibit
• Internal and external printer optionsInternal and external printer options
58
Excel Excel Life SafetyLife Safety
Key Functions (continued)Key Functions (continued)
• Powerful Control-by-Event (CBE) Powerful Control-by-Event (CBE)
• Auto-Learn or PC programmingAuto-Learn or PC programming
• Duplicate address detectionDuplicate address detection
• One-man Walk Test with counterOne-man Walk Test with counter
• Output device testOutput device test
• Daily high testDaily high test
• 2 pulse rates for outputs2 pulse rates for outputs
• Time of day functionsTime of day functions
59
Excel Excel Life SafetyLife Safety
System CapacitySystem CapacityStandStand-Alone-Alone
• Up to 8 loopsUp to 8 loops• 198 (99+99) devices per loop198 (99+99) devices per loop• Up to 99 VIEW™ per loopUp to 99 VIEW™ per loop• Up to 1584 devices Up to 1584 devices • Up to 255 zonesUp to 255 zones• Up to 7A PSUUp to 7A PSU• Up to 31 Up to 31 repeatersrepeaters
• Graphic annunciators (Mimic)Graphic annunciators (Mimic)– Up to 512 LEDs per controller Up to 512 LEDs per controller
• 600 event history log600 event history log
60
Excel Excel Life SafetyLife Safety
System CapacitySystem CapacityStand-Alone (continued)Stand-Alone (continued)
• Four sounder circuits (NACs)Four sounder circuits (NACs)– rated @ 1A eachrated @ 1A each– Two programmable as VF relaysTwo programmable as VF relays
rated @ 30Vdc/1Arated @ 30Vdc/1A• Two 24Vdc auxiliary outputsTwo 24Vdc auxiliary outputs
– rated at 1A eachrated at 1A each• Two programmable inputs Two programmable inputs • SPDT Fault and Fire relaysSPDT Fault and Fire relays
– rated @ 30Vdc/1Arated @ 30Vdc/1A• Two loops as standardTwo loops as standard• One isolated RS232 port (optional)One isolated RS232 port (optional)• One isolated RS485 port (optional)One isolated RS485 port (optional)
61
Excel Excel Life SafetyLife Safety
System CapacitySystem CapacityNetworked - INetworked - I
• Master/Slave networkMaster/Slave network
– Up to 32 network nodesUp to 32 network nodes
– Maximum 8 panelsMaximum 8 panels
– Remainder repeatersRemainder repeaters
and graphic annunciatorsand graphic annunciators
– Up to 64 loopsUp to 64 loops
– Up to 12,672 devicesUp to 12,672 devices
– Up to 2040 zonesUp to 2040 zones
– Up to 56A PSUUp to 56A PSU
– Max. RS485 bus length of 3000mMax. RS485 bus length of 3000m
62
Excel Excel Life SafetyLife Safety
Master/Slave NetworkMaster/Slave Network
• Functionality supported across the network:Functionality supported across the network:– ResetReset
– Silence/Re-soundSilence/Re-sound
– MuteMute
– EvacuateEvacuate
– Point/Zone IsolatePoint/Zone Isolate
– Walk TestWalk Test
– Zone Event BroadcastZone Event Broadcast
– Control by Event (CBE)Control by Event (CBE)
63
Excel Excel Life SafetyLife Safety
Bldg.3
Bldg.2
Bldg.1
Bldg.4
System CapacitySystem CapacityNetworked - IINetworked - II
• Peer-to-peer networkPeer-to-peer network– ArcNet basedArcNet based– Re-transmission and isolation between Re-transmission and isolation between
nodes (1 km btw. nodes)nodes (1 km btw. nodes)– Error checking and correctionError checking and correction
at each nodeat each node– Message routingMessage routing– Up to 100 network nodesUp to 100 network nodes– Up to 158,400 devicesUp to 158,400 devices– Up to 25,500 zonesUp to 25,500 zones– Up to 700A PSUUp to 700A PSU– Network alarm response less than 10 Network alarm response less than 10
secondsseconds
64
Excel Excel Life SafetyLife Safety
Off-Line Configuration ToolOff-Line Configuration Tool
• Stand-alone and Master/Slave networkStand-alone and Master/Slave network
– DOS basedDOS based
– Individual panel programmingIndividual panel programming
– Manual software authenticationManual software authentication
– Same format as ID1000 and ID2000Same format as ID1000 and ID2000
– Minimum training requiredMinimum training required
– No special hardware requirementNo special hardware requirement
– Windows based Loop & Battery Calculator toolWindows based Loop & Battery Calculator tool
• Peer-to-peer networkPeer-to-peer network
– Windows basedWindows based
– System-wide programmingSystem-wide programming
65
Excel Excel Life SafetyLife Safety
Off-Line Configuration ToolOff-Line Configuration ToolWindows versionWindows version
• Windows 95/98/ME/NT4/2000 Operating SystemsWindows 95/98/ME/NT4/2000 Operating Systems
• Windows XP under considerationWindows XP under consideration
• Standard Windows editing features Standard Windows editing features (cut, copy, paste, etc)(cut, copy, paste, etc)
• On-line error checking On-line error checking
• Easy report printoutsEasy report printouts
• On-Line Help menuOn-Line Help menu
66
Excel Excel Life SafetyLife Safety
On-Site ConfigurationOn-Site Configuration
• Multi-level password/key-switch accessMulti-level password/key-switch access
– Level 2: Code 1/Keyswitch - Panel controls & menusLevel 2: Code 1/Keyswitch - Panel controls & menus
– Level 3: Code 2 - Level 2 + Configuration menusLevel 3: Code 2 - Level 2 + Configuration menus
– Level 3A: Code 3 - Level 3 + Advanced Configuration Level 3A: Code 3 - Level 3 + Advanced Configuration
• Panel settingsPanel settings
• Auto-learn facilityAuto-learn facility
• Loop/Device configurationLoop/Device configuration
• Text Editor (Virtual keyboard)Text Editor (Virtual keyboard)
• Control matrix editor (512 lines)Control matrix editor (512 lines)
• Network configurationNetwork configuration
67
Excel Excel Life SafetyLife Safety
User MenuUser Menu
C o n f i g u r a t i o n (E n t e r L e v e l 3 P a s s c o d e)
68
Excel Excel Life SafetyLife Safety
Use Use to scroll through inputs currently under walk-test.to scroll through inputs currently under walk-test.
Either Tested or Not Tested is highlighted for that device.Either Tested or Not Tested is highlighted for that device.
Use Use to scroll through device descriptions.to scroll through device descriptions.
F I R E
B R E A K G L A S S
P R E S S H E R E
LED ON for 5sec
1 sec ON or 1 sec ON or follow mefollow me
Easy-to-use Test ModeEasy-to-use Test Mode
69
Excel Excel Life SafetyLife Safety
Lamp Test checks all panel LED’s, Buzzer, L.C.D. & Contrast Lamp Test checks all panel LED’s, Buzzer, L.C.D. & Contrast adjustmentadjustment
User Menu - ExamplesUser Menu - Examples
70
Excel Excel Life SafetyLife Safety
Lamp Test also displays Panel & LIB software versionsLamp Test also displays Panel & LIB software versions
User Menu - ExamplesUser Menu - Examples
71
Excel Excel Life SafetyLife Safety
Level 3 AccessLevel 3 Access
Configuration:Configuration:1: Loop Device Configuration (auto-learn)1: Loop Device Configuration (auto-learn)
2: Zone Text Editor2: Zone Text Editor
3: Panel Text Editor3: Panel Text Editor
4: Control Matrix Configuration (512 lines)4: Control Matrix Configuration (512 lines)
5: Network Configuration5: Network Configuration
6: Panel Settings6: Panel Settings
Configuration MenuConfiguration Menu
72
Excel Excel Life SafetyLife Safety
Loop Device ConfigurationLoop Device Configuration
Configuration Menu - 2Configuration Menu - 2
73
Excel Excel Life SafetyLife Safety
Configuration Menu - 3Configuration Menu - 3
74
Excel Excel Life SafetyLife Safety
Network ConfigurationConfiguration
Configuration Menu - 4Configuration Menu - 4