home inspection report · home inspection report 555 wind way, fake city , or 54645 inspection...
TRANSCRIPT
Home Inspection Report
555 Wind Way, Fake City , OR 54645
Inspection Date:Monday May 12, 2014
Prepared For:John Doe
Prepared By:House to Home
3468 N. Bartlett AveMilwaukee, WI 53211
Report Number:14-0512
Inspector:Christopher Chirafisi
555 Wind Way, Fake City , OR 54645 Page 2
This confidential report is prepared exclusively for John Doe©2014 House to Home
Receipt/InvoiceHouse to Home3468 N. Bartlett AveMilwaukee, WI 53211Date: May 12, 2014 Inspection Number: 14-0512Inspected By: Christopher Chirafisi
Client: John DoeInspection FeeInspection Fee $350.00
Total $350.00X Check: Cash Credit Card
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 3
This confidential report is prepared exclusively for John Doe©2014 House to Home
Report OverviewTHE HOUSE IN PERSPECTIVE
Typical Construction
CONVENTIONS USED IN THIS REPORT
SATISFACTORY - Indicates the component is functionally consistent with its original purpose but may show signs of normal wear and tear and deterioration.
MARGINAL - Indicates the component will probably require repair or replacement anytime within five years.POOR - Indicates the component will need repair or replacement now or in the very near future.MAJOR CONCERNS - A system or component that is considered significantly deficient or is unsafe.SAFETY HAZARD - Denotes a condition that is unsafe and in need of prompt attention.
THE SCOPE OF THE INSPECTION
All components designated for inspection in the WI Standards of Practice are inspected, except as may be noted in the "Limitations of Inspection" sections within this report. It is the goal of the inspection to put a home buyer in a better position to make a buying decision. Not all improvements will be identified during this inspection. Unexpected repairs should still be anticipated. The inspection should not be considered a guarantee or warranty of any kind. Please refer to the pre-inspection contract for a full explanation of the scope of the inspection. Visual Inspection Only
BUILDING DATA
Approximate Age: 77 Years
Style: Single Family
Main Entrance Faces: South
State of Occupancy: Vacant
Weather Conditions: Rain
Recent Rain: Yes
Ground Cover: Wet
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 4
This confidential report is prepared exclusively for John Doe©2014 House to Home
Report SummaryItems Not Operating
Light on exterior or home and bathroom exhaust fan
Major ConcernsItem(s) that have failed or have potential of failing soon.
None apparent
Potential Safety HazardsWalkway had some cracking and settlement, should be repaired and/or replaced as needed. Safety Cable Recommended on garage door springs. Exposed wires on exterior and in attic.
Deferred Cost ItemsItems that have reached or are reaching their normal life expectancy or show indications that they may require repair or
replacement anytime during the next five (5) years.
None apparent
Improvement ItemsGrading
Items to MonitorCrack in foundation and roofing cement on chimney
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 5
This confidential report is prepared exclusively for John Doe©2014 House to Home
GroundsService Walks
Material X ConcreteCondition X Marginal X Trip hazardComments Walkway had some cracking and settlement, should be repaired and/or replaced as needed. Potential tripping hazardDriveway/Parking
Material X ConcreteCondition X Satisfactory X Typical cracksPorch
Condition X MarginalSupport Pier X WoodFloor X SatisfactoryComments Porch posts had some damaged wood and was in need of repair and/or replacement. Support pier is not properly
supported, repair as necessary. Stoops/Steps
Material X ConcreteCondition X Satisfactory X SettledLandscaping affecting foundation
Negative Grade X West X North X Recommend window wells/coversComments Metal window wells were rusted recommend repairing/replacing as neededHose bibs
Condition X Satisfactory X No anti-siphon valve X Recommend Anti-siphon valveOperable X Yes
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 6
This confidential report is prepared exclusively for John Doe©2014 House to Home
Grounds Photos
Rusting of window wells repair/replace as needed
Wood rot on support pier on front porch recommend replacing damaged wood.
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 7
This confidential report is prepared exclusively for John Doe©2014 House to Home
RoofRoof Visibility
X AllInspected From
X Ladder at eavesComments Roof inspection was limited to inspecting from the eaves due to roof pitch. Style of RoofType X GablePitch X SteepRoof #1 Type: Asphalt Layers: 2 Age: UnknownVentilation System
Type X Gable X RoofComments Recommend additional ventilation as an improvement to help prolong the life of the roof.FlashingMaterial X Galv/AlumCondition X Not Visible X Marginal X Rusted X Recommend SealingComments Flashings are not visible around chimney covered with roofing cement so not visible recommend monitoring for
leaks. Recommend flashing above front porch where wall meets roof to prevent any water penetration into home.Condition of Roof CoveringsRoof #1 X SatisfactoryCondition X Granules missingComments Roof was showing normal wear, but was in overall adequate condition. Plumbing Vents
Condition X Satisfactory
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 8
This confidential report is prepared exclusively for John Doe©2014 House to Home
Roof Photos
Missing wall to roof flashing recommend installing one to prevent water penetration into home.
Damaged screen on roof vent recommend replacing screen to prevent pests from entering attic
Chimney flashing covered with roofing cement not visible.
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 9
This confidential report is prepared exclusively for John Doe©2014 House to Home
ExteriorChimney(s)
Location(s): West Viewed From X Ladder at eavesRain Cap/Spark Arrestor X YesChase X BrickEvidence of X Cracked chimney capFlue X TileEvidence of X Not evaluatedCondition X Satisfactory X Recommend RepairComments Small crack on chimney crown recommend minor tuckpointingGutters
Condition X SatisfactoryMaterial X Galvanized/AluminumExtension needed X SouthComments Maintain downspout discharge away from the house. SidingMaterial X Wood X Peeling paintCondition X Satisfactory X Recommend repair/paintingComments Siding was showing some wear, but still in functional condition. Siding was in need of normal painting / staining
maintenance. TrimMaterial X Wood X Recommend repair/painting X Damaged woodCondition X MarginalComments Trim had some deterioration and is in need minor repairs and painting. Soffit
Material X Wood X Recommend repair/painting X Damaged woodCondition X MarginalComments Small portion of soffits has wood rot recommend replacing damaged wood.Fascia
Material X WoodCondition X SatisfactoryCaulking
Condition X Marginal X Recommend around windows/doors/masonry ledges/corners/utility penetrations Windows/ScreensCondition X Satisfactory X Wood rot X Recommend repair/paintingMaterial X Wood X Aluminum/Vinyl cladComments Cracked window on basement window (East and West) as well as attic window repair as needed. Storms WindowsCondition X Satisfactory X Wood rot X Recommend repair/paintingMaterial X Wood X MetalPutty X NeededComments Frame rotted/damaged, repair/replace as needed on attic window. Weep holes not present at bottom of storm
windows. Storms and screens were generally reviewed from the exterior only. Storms and screens were not operated.
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 10
This confidential report is prepared exclusively for John Doe©2014 House to Home
ExteriorFoundationFoundation Wall X Concrete blockCondition X SatisfactoryComments Foundation (stem) wall contains typical cracks. Service Entry
X Overhead Condition: X Satisfactory Marginal PoorExterior receptacles X NoGFCI present X NoComments Exposed wires running from home to garage recommend repair by a qualified electrician potential safety hazard.
Could not verify if light on northside of exterior of home worked.Building(s) Exterior Wall ConstructionType X Not VisibleCondition X Not VisibleComments Building structure not visible due to siding, not evaluated. Exterior DoorsMain Entrance Weatherstripping: X Satisfactory Marginal Poor Missing Replace
Door condition: Satisfactory X Marginal PoorSide door Weatherstripping: X Satisfactory Marginal Poor Missing Replace
Door condition: X Satisfactory Marginal PoorComments Small crack on front door , door still usable repair as needed.Exterior A/C - Heat pump #1Unit #1 Location: Exterior North Brand: Goodman Model #: GSC130241DA Serial #: 0906746741
Approximate Age: 5-8 YearsCondition X SatisfactoryEnergy source X ElectricUnit type X Air cooledOutside Disconnect X Yes Maximum fuse/breaker rating (amps): 15 Fuses/Breakers installed (amps): 15Level X YesCondenser Fins X SatisfactoryImproper Clearance (air flow) X NoComments Damaged/Missing insulation on refrigerant line recommend replacing
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 11
This confidential report is prepared exclusively for John Doe©2014 House to Home
Exterior Photos
Exposed wires recommend repair by a qualified electrician.
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 12
This confidential report is prepared exclusively for John Doe©2014 House to Home
Garage/CarportType
X Detached X 1-CarAutomatic Opener
X Yes X OperableSafety Reverse
X Not testedComments Safety reverse could not be tested do to damage to the door.RoofingMaterial X Same as houseGutters/EavestroughCondition X NoneSiding
Material X Same as houseCondition X Marginal X Recommend repair/replace X Recommend paintingComments Siding had some damage and was in need of repairs. Recommend trimming trees and keeping soil 6-8" away from
sidingTrim
Material X Same as houseCondition X Marginal X Recommend repair/replace X Recommend paintingComments Trim had some damage and was in need of repairs. FloorMaterial X ConcreteCondition X Satisfactory X Typical cracksSill Plates
X Floor levelOverhead Door(s)
Material X WoodCondition X Poor X Safety Cable RecommendedRecommend Priming/Painting Inside & Edges X YesComments Garage door was damaged and in poor condition recommend repair / replacement. Electrical Receptacles
Reverse polarity X NoOpen ground X NoGFCI Present X No X Recommend GFCI Receptacles
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 13
This confidential report is prepared exclusively for John Doe©2014 House to Home
Garage/Carport Photos
Areas of siding on garage are damaged recommend repair/replacing damaged areas as needed.
Overhead door damaged recommend repair/replacement
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 14
This confidential report is prepared exclusively for John Doe©2014 House to Home
KitchenCountertops
X SatisfactoryCabinets
X SatisfactoryPlumbingFaucet Leaks X NoPipes leak/corroded X NoSink/Faucet X SatisfactoryFunctional drainage X SatisfactoryFunctional flow X SatisfactoryWalls & CeilingCondition X SatisfactoryHeating/Cooling Source
X YesFloorCondition X SatisfactoryAppliancesDisposal Operable: X Yes NoOven Operable: X Yes NoRange Operable: X Yes NoDishwasher Operable: X Yes NoExhaust fan Operable: X Yes NoRefrigerator Operable: X Yes NoDishwasher airgap X YesReceptacles present X Yes Operable: X Yes NoGFCI X No Recommend GFCI Receptacles: X Yes NoOpen ground/Reverse polarity: X NoComments Loose receptacle near fridge recommend securing.
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 15
This confidential report is prepared exclusively for John Doe©2014 House to Home
Laundry RoomLaundryLaundry sinkFaucet leaks X NoPipes leak X NoCross connections X NoHeat source present X YesRoom vented X YesDryer vented X WallElectrical Open ground/reverse polarity: Yes X NoGFCI present X No X Recommend GFCI ReceptaclesAppliances X Washer X DryerWasher hook-up lines/valves X SatisfactoryGas shut-off valve X N/A
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 16
This confidential report is prepared exclusively for John Doe©2014 House to Home
BathroomBathLocation First floorSinks Faucet leaks: Yes X No Pipes leak: X Yes NoTubs Faucet leaks: Yes X No Pipes leak: Yes X No Not VisibleShowers Faucet leaks: Yes X No Pipes leak: Yes X No Not VisibleToilet Bowl loose: Yes X No Operable: X Yes NoShower/Tub area X Fiberglass Condition: Satisfactory X Marginal Poor Rooted floors
Caulk/Grouting needed: X Yes No Where: Inside of tub and where tub meets floorDrainage X SatisfactoryWater flow X SatisfactoryMoisture stains present X NoDoors X SatisfactoryWindow X MarginalReceptacles present X Yes Operable: X Yes NoGFCI X Yes Operable: X Yes NoOpen ground/Reverse polarity X NoHeat source present X YesExhaust fan X Yes Operable: Yes X NoComments GFCI loose near vanity recommend repair. Window did not open with normal pressure repair as needed. Toilet was
slow to flush repair as needed.Pipes are leaking - recommend repair and/or replacement as necessary. Caulk or grouting needed in tub area.
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 17
This confidential report is prepared exclusively for John Doe©2014 House to Home
Living RoomRoom
Location: South Type: LIVING ROOM Walls & Ceiling X Satisfactory X Typical cracksMoisture stains X NoFloor X SatisfactoryCeiling fan X NoneElectrical Operable: X Yes No Switches: X Yes No X Operable Receptacles: X Yes No X Operable
Open ground/Reverse polarity: Yes X NoHeating source present X YesDoors X SatisfactoryWindows X MarginalComments Some windows were difficult to open adjust as needed. Recommend properly sealing area where air conditioner use
to be.
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 18
This confidential report is prepared exclusively for John Doe©2014 House to Home
Master BedroomRoom
Location: First floor Type: MASTER BEDROOM Walls & Ceiling X Satisfactory X Typical cracksMoisture stains X NoFloor X SatisfactoryCeiling fan X Satisfactory X NoisyElectrical Operable: X Yes No Switches: X Yes No X Operable Receptacles: X Yes No X Operable
Open ground/Reverse polarity: Yes X NoHeating source present X YesBedroom Egress restricted X NoDoors X SatisfactoryWindows X SatisfactoryComments Recommend installing cover on closet lights
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 19
This confidential report is prepared exclusively for John Doe©2014 House to Home
BedroomRoom
Location: NW Type: BEDROOM Walls & Ceiling X SatisfactoryMoisture stains X Yes Where: CeilingFloor X SatisfactoryCeiling fan X SatisfactoryElectrical Operable: X Yes No Switches: X Yes No X Operable Receptacles: X Yes No X Operable
Open ground/Reverse polarity: Yes X NoHeating source present X YesBedroom Egress restricted X NoDoors X SatisfactoryWindows X Satisfactory
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 20
This confidential report is prepared exclusively for John Doe©2014 House to Home
BedroomRoom
Location: E Type: BEDROOM Walls & Ceiling X SatisfactoryMoisture stains X NoFloor X SatisfactoryCeiling fan X SatisfactoryElectrical Operable: X Yes No Switches: X Yes No X Operable Receptacles: X Yes No X Operable
Open ground/Reverse polarity: Yes X NoBedroom Egress restricted X NoDoors X SatisfactoryWindows X MarginalComments Windows difficult to open recommend repair/adjusting as needed. Recommend properly sealing area where air
conditioner use to be.
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 21
This confidential report is prepared exclusively for John Doe©2014 House to Home
InteriorSmoke/Carbon Monoxide detectorsSmoke Detector X Present Operable: X Yes No Not tested Recommend additionalCO Detector X Non Present Operable: Yes No Not tested X Recommend additionalComments Recommend adding additional smoke detectors and carbon monoxide detectors throughout home. Attic/Structure/Framing/Insulation
Access X Scuttlehole/HatchInspected from X In the atticLocation X Bedroom HallFlooring X NoneInsulation X Fiberglass X Batts X Loose X Other Depth: 6-9"Installed in X Between ceiling joists X Recommend additional insulationVapor barriers X Not VisibleVentilation X Recommend additional ventilationFans exhausted toAttic: X Yes No X Recommend repairChimney chase X SatisfactoryStructural problems observed X NoRoof structure X Trusses X MetalCeiling joists X MetalSheathing X Planking X StainedEvidence of condensation X NoEvidence of moisture X YesEvidence of leaking X YesElectrical X Exposed wiresComments Recommend properly venting bathroom and kitchen exhaust to exterior. Exposed wires recommend a qualified
electrician properly terminate in junction box. Old stains on wood no apparent leaking at time of inspection.
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 22
This confidential report is prepared exclusively for John Doe©2014 House to Home
Interior Photos
Recommend exhausting to exterior Exposed wires recommend terminating in junction box
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 23
This confidential report is prepared exclusively for John Doe©2014 House to Home
BasementStairsCondition X Satisfactory X Typical wear and tearHandrail X Yes Condition: X Satisfactory LooseHeadway over stairs X Low clearanceFoundationCondition X SatisfactoryMaterial X Concrete blockStep cracks X EastMovement apparent X EastIndication of moisture X Yes X Old stainsComments Foundation had some typical minor cracks. Recommend monitoring the cracks for future movement. Someof the
foundation walls were covered with paneling/drywall and were not visible. FloorMaterial X ConcreteCondition X Satisfactory X Typical cracksDrainageSump pump X NoFloor drains X Yes X Drains not testedGirders/Beams
Condition X SatisfactoryMaterial X SteelColumns
Condition X SatisfactoryMaterial X SteelJoists
Condition X SatisfactoryMaterial X Steel X TrussSubfloor
X Indication of moisture stains/rottingComments Area around shower stalls have old moisture stains present. Area around toilets have old moisture stains present. Area
under the kitchen sink has old moisture stains present.
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 24
This confidential report is prepared exclusively for John Doe©2014 House to Home
PlumbingWater service
Main shut-off location: BasementWater entry piping X LeadLead other than solder joints X UnknownVisible water distribution piping X Copper X Galvanized X CPVC PlasticCondition X SatisfactoryFlow X SatisfactoryPipes Supply/Drain X Corroded X Leaking X Dissimilar metal Cross connection: Yes X No Safety HazardDrain/Waste/Vent pipe X Cast ironCondition X MarginalSupport/InsulationType: MetalTraps proper P-Type X No X P-traps recommendedDrainage X SatisfactoryFuel line X Galvanized X Black ironCondition X SatisfactoryComments Leak on drain from bathroom sink recommend repairMain fuel shut-off location
On the side exterior wall Water heater #1
Brand Name: Richmond Serial #: RMLN1106406667 Capacity: 40 Gallons Approx. age: 8 Type X GasCombustion air venting present X YesSeismic restraints needed X NoRelief valve X Yes Extension proper: X Yes No Missing Recommend repair Improper materialVent pipe X Satisfactory X Pitch properCondition X Satisfactory
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 25
This confidential report is prepared exclusively for John Doe©2014 House to Home
Heating SystemHeating systemUnit #1 Brand name: Goodman Approx. age: 6 years Model #: GMH950703BXAC Serial #: 0908093106Energy source X GasWarm air system X Direct drive X Central systemHeat exchanger X Sealed X Not VisibleCombustion air venting present X YesControls Disconnect: X Yes No X Normal operating and safety controls observedDistribution X Metal ductFlue piping X SatisfactoryFilter X Standard X SatisfactoryWhen turned on by thermostat X Fired Proper operation: X Yes No Not tested#1 - System condition X Satisfactory
This confidential report is prepared exclusively for John Doe©2014 House to Home
555 Wind Way, Fake City , OR 54645 Page 26
This confidential report is prepared exclusively for John Doe©2014 House to Home
Electric/Cooling SystemMain panel
Location: BasementCondition X SatisfactoryAdequate Clearance to Panel X YesAmperage/Voltage X 100a X 120v/240vBreakers/Fuses X BreakersAppears grounded X YesGFCI breaker X NoAFCI breaker X NoMain wire X Copper Condition: X Satisfactory Marginal PoorBranch wire X Copper X Copper clad aluminumBranch wire condition X Satisfactory X Romex X Conduit X Double tappingA/C Unit
X Central system Brand Name: Goodman Location: Basment Age: 6 years Serial #: GMH950703BXACEvaporator coil X Not VisibleRefrigerant lines X SatisfactoryCondensate line/drain X Floor drainCondition X Satisfactory
This confidential report is prepared exclusively for John Doe©2014 House to Home