Holistic Approach for Analytical Method Transfer
Nathaniel Hentz, Ph.D.Director, Scientific Market Development
Artel, Inc.
© 2019 Artel2
© 2013 ARTEL
Key Phases in Assay AutomationPhase 1: Biology Phase 2: Automation
Method
Transfer
© 2019 Artel3
© 2013 ARTEL
Method Transfers Are CriticalMany reasons for failure
Poor documentationInsufficient communication
Improper trainingPoor equipment qualification
Weak method development/validationPoor acceptance criteria/specifications
10-40% method
transfers fail
© 2019 Artel4
© 2013 ARTEL
Method Transfers Are CriticalMany reasons for failure
Poor documentationInsufficient communication
Improper trainingPoor equipment qualification
Weak method development/validationPoor acceptance criteria/specifications
10-40% method
transfers fail
*Artel MVS can address these issues
© 2019 Artel5
© 2013 ARTEL
Assay
Detector
ALH Settings
Sample
Environment
Parameters that Effect Assay VariabilityHardware /
LabwarePlate type, tip type, tubing, automation
Off-set volume, single/multi dispense, aspirate/dispense rate, aspirate/dispense height, liquid class, pre / post air gaps, etc.
PMT, wavelength, x-y-z position
Mixing, incubation time, centrifugation, # liquid transfers, wash steps, dilution steps, serial dilutions
Viscosity, density, surface tension, volatility
Temperature, humidity, light, vibration
Process
© 2019 Artel6
© 2013 ARTEL
The Problem
© 2019 Artel7
© 2013 ARTEL
The Solution
© 2019 Artel8
© 2013 ARTEL
The Result
Good Assay
0 1 2 2 4 3 6 4 8 6 0 7 2 8 4 9 60
2 0 0 0
4 0 0 0
6 0 0 0
8 0 0 0
1 0 0 0 0
W e ll ID
Sig
na
l (R
FU
)
Z’ = 0.74
Better Assay
0 1 2 2 4 3 6 4 8 6 0 7 2 8 4 9 60
2 0 0 0
4 0 0 0
6 0 0 0
8 0 0 0
1 0 0 0 0
W e ll ID
Sig
na
l (R
FU
)
Z’ = 0.94
© 2019 Artel9
© 2013 ARTEL
How is This Accomplished?
Process Optimization
© 2019 Artel10
© 2013 ARTEL
The Result
-2 -1 0 1 20
1000
2000
3000
4000
Log Inhibitor (nM)
Sign
al (
RFU
)Opt 1Opt 2Opt 3
© 2019 Artel11
© 2013 ARTEL
Value Proposition
Reduce error rates
Minimize overall
variability
Improve data resolution
Speed method transfer
© 2019 Artel12
© 2013 ARTEL
Q&A
© 2019 Artel13
© 2013 ARTEL
Thank YouWould you like more information?
1. N. Hentz and E. Avis. Improving Assay Performance Using a Process Optimization Approach; SLAS2017 poster.
2. N. Hentz and T. Knaide. Effect of Liquid-Handling Accuracy on Assay Performance; J. Lab. Automation, 2014, 19(2) 153–162.