hmi scada-02 - wonderware softwareglobal.wonderware.com/en/softwaregcc15ppts/hmi scada 02...
TRANSCRIPT
Initially we had Inputs and Outputs …so we created Input/Output servers (IO Servers)
Then we added different data types
…so we created Data Access servers (DAServers)
Let’s see what that looks like today
So we will have an industry wide, global, IOT and cloud ready communication strategy
Increase Scalability
What makes this different?
Each new part of the solution will be able to:
Increase throughput
Eliminate single points of failure
Maximize communication uptime
Support multiple versions
Auto-generate content
Discover devices
Contextualize Data
Generate Alarms & Events
Historize
Standards Compliant Clients
Protocol Specific Servers
A-B GE
Supervisory
…
Telemetry
DNP3 IEC …
DDE SL OPC OPC-UA
Supervisory Clients Cloud Clients
? HTTP
MQTT LoRa
Internet of Things
…
Gateway
Device Layer DCSs Smart Devices PLCs Telemetry IOT
Expanding Offering
1 License Per Node
Automation Direct WAGO
BACNET
Beckhoff / TwinCAT
EATON
Mitsubishi
OPTO 22
Reduce Application Costs • Increase Single Node Scalability
• Eliminate the limitations of a single driver in a single node. You can run multiple completely independent instances of the same driver in a single node
PC-1
With OI Servers
PC-1 PC-n PC-2
PC-2
Improve Robustness • Eliminate single points of failure
• By running multiple instances of the same node any potential problems that may affect one driver instance are isolated to just that instance.
With OI Servers
PC-2
PC-2
Reduce Downtime • Maximize communication uptime
• Reduce impact of configuration changes that require driver restarts to a single instance thus allowing other drivers to continue to run unaffected.
With OI Servers
PC-2
Reset
Reset
Improve Performance • Increase throughput
• Parallel independent processing of I/O by each individual driver instance results in my higher overall throughput per driver and per node.
With OI Servers
CPU
Time Startup
Cycle Time
CPU
Time Startup
Cycle Time
CPU
Time
CPU
Time
CPU
Time
PC-2 PC-2
Side-by-Side Compatibility • Single Protocol Supports multiple versions
• Single node side-by-side upgrades allows continuing to run the previous driver version while adding a new version of the same driver protocol.
• Keep the old while adding new without having to change existing versions thus allowing continued growth without disruptions
PC-2
With OI Servers
PC-2
b DI Object
PC-2
b DI Object
2.0 3.0 2.0 4.0 4.0
On a Single Node Standard Professional Premier Server Types Supervisory Supervisory Telemetry
Drivers Supported All Supervisory All Supervisory All
I/O per Instance Device Specific Device Specific Future
Network Redundancy Future
Hardware Consolidation Future
Reduce Architecture Costs Future
Single Node Scalability Future
Load Distribution Future
Increased Throughput Future
Maximize Uptime Future
Single Protocol Multi-Version Future
Future Allen-Bradley
Automation Direct Bosch
Beckhoff Eaton
GE Mitsubishi
Omron Opto22
Modbus / Modicon Siemens
Wago Wonderware
More Licensing
x WSP 2012 R2 x WSP
2014 x WSP 2014 R2
License Feature and Version DAServer 10.6 DAServer 11.0 DAServer 11.1
Standard OI Server
Functionality
Upgrade to DAServer 11.1
Upgrade to DAServer 11.1
Already supported DAServer 11.1
Professional OI Server
Functionality
Upgrade to OI_Server 11.1
Upgrade to OI_Server 11.1
Upgrade to OI_Server 11.1
OI Servers require 11.1
or higher
OI Servers Professional covers both
Standard and Professional functionality
Wonderware Conference. Schneider Electric confidential.
SIEMENS ●S7-1500 Full Support…
●European market ●User Data Types (Symbolic)
Support ● ~Q2/Q3 2015
Beta
●Q4 2015
Important! ●Will release as an OI Server ●No DAServer or DI Object
Wonderware Conference. Schneider Electric confidential.
Wonderware OPC UA Client (Stand-alone)
●Why is Stand-alone important? ●Support OEMs ●Global market ● InTouch Stand-alone ●Non System Platform
Implementations (InBatch) ● ~Q2/Q3 2015
●Q4 2015
Important! ●Will be part of OI Gateway ●FSGateway becomes OI Gateway
Wonderware OI Gateway
• Increase Single Node Scalability • Eliminate the limitations of a single driver in a
single node. You can run multiple completely independent instances of the same driver in a single node
• Typical Historian Scalable Architecture • Customer wants to integrate 3rd party
products to Historian • Individual DAServers are not scalable enough • OI Server Architecture allows multi-Instance
• Only limited by hardware constraints
PC-x …
New OI Servers? ●Conversion of DAServer to OI Server
●OMRON ● ITME (InTouch Machine Edition)
●New OI Servers ●Modbus Serial ●Texas Instruments ●DNP3 ●ABB Totalflow ●CANopen ●Additional Automation Direct ●Additional Mitusibishi
©2015 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies or their respective owners.
Thank you!