Page 2: HiT70xx Commissioning Guide

ContentsInstalling The FTP-Server: ........................................................................................................................3Install TNMS CT (NCT) Stand Alone (Single User).................................................................................5Installing TNMS Licenses:......................................................................................................................10Basic Setup Of A hiT 70xx Via Console..................................................................................................16Setting Up TNMS (NCT) For Network Element Access.........................................................................19Basic Commissioning Of hiT 70xx..........................................................................................................26Configuring STM Interfaces....................................................................................................................32Configuring DCC Management...............................................................................................................34Configuring A PDH Port (E1)..................................................................................................................35Configuring Ethernet................................................................................................................................36Creating A Cross Connection...................................................................................................................42Enabling Alarms.......................................................................................................................................44Clock Synchronization.............................................................................................................................46Protection.................................................................................................................................................50Saving / Restoring the MIB.....................................................................................................................61LP-201 IP Phone Setup............................................................................................................................63

Page 3: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Installing The FTP-Server: Settings->Control Panel + Add or Remove Programs + Add / Remove Windows Components:Select Internet Information Services:

© 2010 Siemens AG 3

Page 4: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Press “Details” and select File Transfer Protocol:

Start the installation. It might be necessary to have the XP installation CD/DVD at hand.

© 2010 Siemens AG 4

Page 5: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Install TNMS CT (NCT) Stand Alone (Single User)Start Install.exe from DVD. Select NCT:

© 2010 Siemens AG 5

Page 6: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

In the next screen, make sure that both client and server are selected:

© 2010 Siemens AG 6

Page 7: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Click Next and wait...

© 2010 Siemens AG 7

Page 8: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Accept the license agreement, select whether you like a wallpaper or not, and then choose the network elements, that you have in your network. Attention: select only what you need, otherwise lots of data is copied onto your computer!

© 2010 Siemens AG 8

Page 9: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Click Next and wait...

After the installation has finished, restart your computer.

© 2010 Siemens AG 9

Page 10: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Installing TNMS Licenses:After rebooting your PC, start TNMS for the first time. Leave the password field empty and press “Login”:

© 2010 Siemens AG 10

Page 11: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

An advisory window opens. Click “OK”:

(you can disable this window in the dialog “Security->Settings”)

© 2010 Siemens AG 11

Page 12: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Now, enter a new password. The password must consist of at least 8 characters, including one numeric and one special character:

You will get a message telling you, that there's no basic license installed:

© 2010 Siemens AG 12

Page 13: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Click “OK” and a window opens, where you can add the licenses that were purchased for your TNMS. For a working NCT installation, you will need the basic license, a feature license for each multiplexer type, and a network element license for each multiplexer that shall be managed from TNMS.

© 2010 Siemens AG 13

Page 14: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

First, install the basic license. Then select Configuration->License... from the toolbar to import the feature and network element licenses.

© 2010 Siemens AG 14

Page 15: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Basic Setup Of A hiT 70xx Via ConsoleBefore you can power up the hiT 70xx, you have to install the SD card containing the firmware. Switch the hiT on and connect a PC to the serial console interface. You need a straight cable with female DSub9 plugs at both ends and a terminal software on your PC like HyperTerminal or TeraTerm, serial settings are 9600 8N1.

Log in as <root> without password

© 2010 Siemens AG 15

Page 16: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Change IP parameters: management IP address must belong to local substation net, node IP must belong to node network, gateway must be the address of the PC connected to management port

© 2010 Siemens AG 16

Page 17: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Connect management port to PC (straight CAT5) and verify your network settings: open a command prompt and ping management port and node addresses:

© 2010 Siemens AG 17

Page 18: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Setting Up TNMS (NCT) For Network Element AccessOpen Configuration->DCN Management. Create the SNMP structure of the network elements. First, add a new SNMP object by hovering the mouse offer the TNMS-Server icon and selecting “New...” in the context menu.

The SNMP properties dialog opens. You can leave everything on default values.

© 2010 Siemens AG 18

Page 19: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Click “OK” and select “NEW...” in the context menu of the SNMP object.

Select the correct template for your network element and fill in the settings. The two most common ones are “Universal SNMPv2” and “Universal SNMPv3”.

© 2010 Siemens AG 19

Page 20: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

© 2010 Siemens AG 20

General Settings for a hiT 7060. the “Universal SNMPv2” template is used.

Page 21: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

© 2010 Siemens AG 21

SNMP settings for a hiT 7060. Only the node IP address is needed (passwords are already preset).

Page 22: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

© 2010 Siemens AG 22

Settings for a hiT7025. Select the Universal SNMPv3 template. The initial password in "NSN!e2eNet4u"

Page 23: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

© 2010 Siemens AG 23

This is the setup for another template called "hiT7025 4.2", suitable for NCT operation.

Page 24: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

make sure, that everything in the TNMS-CT Server tree is activated.

© 2010 Siemens AG 24

Page 25: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Basic Commissioning Of hiT 70xxOpen the network view in TNMS and double-click onto the node icon that is connected to your computer.

© 2010 Siemens AG 25

Page 26: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

The LCT should start.

In case, you have only read access, you can get write access by selecting “NE Security->Request Write Access”

© 2010 Siemens AG 26

Page 27: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

In <Configuration->NE->Main Shelf Property Configuration> enter some information about the NE.

© 2010 Siemens AG 27

Page 28: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Select “NE Time Setting” and enter your LAN NTP server address in the “NTP Time Server IP” field. Make sure, that Port 123/UDP of your server machine is open (firewall settings) and the NTP server is active

© 2010 Siemens AG 28

Page 29: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

You can verify, that the NTP protocol works by inspecting the network traffic with sniffer software like e.g. Wireshark

© 2010 Siemens AG 29

Excerpt from a Wireshark session. You can see how the NTP client requests are followed by a NTP server reply.

Page 30: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Configuring STM InterfacesHover mouse over the STM card in the LCT and right-click. Open “Card Properties Configuration”. Make sure, that the working mode corresponds to the equipped laser modules and that the admin status of used modules is enabled.

© 2010 Siemens AG 30

Page 31: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Hover mouse over port symbol on card, right click and open “TP Multiplexing Structure”. Configure AU-4 for 140MBit/s, TU-3 for 45 Mbit/s or TU-12 for 2MBit/s.

© 2010 Siemens AG 31

Page 32: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Configuring DCC ManagementIn <DCN->DCC Management> make sure, that for used ports the MS/RS DCC Protocol is set to HDLC (for RIP) and MS/RS DCC Mode is enabled.

© 2010 Siemens AG 32

Page 33: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Configuring A PDH Port (E1)Hover the mouse over the E1 card in LCT, right click and select “Port Property Configuration”. Select the port, check the E1 parameters and that the admin mode is “Enabled”

When the PDH port is properly configured, you can create a cross connection.

© 2010 Siemens AG 33

Page 34: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Configuring EthernetIn the context sensitive menu of the ethernet card select “WAN Ports TP structure”. Here you have to define the multiplexer structure of the ethernet card.

© 2010 Siemens AG 34

Page 35: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Select “LAN Ports Property Configuration”. Select the port, that you want to configure. In the next window, set the proper VLAN ID in the PVID field. The PVID is the VLAN, that this port belongs to.

© 2010 Siemens AG 35

Page 36: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Hover the mouse over the ethernet card and select “WAN Ports Property Configuration”. (A WAN port is a virtual port that connects to the line side). Click the “Bandwidth Management” button.

© 2010 Siemens AG 36

Page 37: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Here you have to define a virtual concatenation group (VCG): a bandwidth that shall be used for the WAN port. Select VC3 or VC12 and select the virtual containers that shall be used.

© 2010 Siemens AG 37

Page 38: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Select VLAN Management. Make sure, that the WAN port, that shall be used for transmission, has all necessary VLAN IDs defined (more than one is possible).

© 2010 Siemens AG 38

Page 39: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

If needed, change the VLAN configuration by clicking the “VLAN Configuration” button. The VLAN Management can be done on port based or VLAN ID based.

After the VLLAN IDs are assigned to the correct LAN and WAN ports, you can create a cross connection.

© 2010 Siemens AG 39

Page 40: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Creating A Cross ConnectionSelect “Cross Connect Management”, either in the top level menu “Configuration” or in the context menu of a CC card.

© 2010 Siemens AG 40

Page 41: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Click “Query” to get a list of current cross connections. To add a new connection, click “Create”.

© 2010 Siemens AG 41

This dialog adds a new ethernet connection. Note, that there's no physical LAN port selected. Instead, a virtual port vP01 is selected.. The WAN port has been previously assigned to a VCG of one TU3.

Page 42: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Enabling AlarmsBy default, Alarms are disabled. In order to enable alarms on the hiT, select <Fault->Alarm Inhibit Configuration> and remove the marker from the first check box. If needed, you can inhibit alarms for specific cards or ports.

© 2010 Siemens AG 42

Page 43: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

In order to activate the alarm outputs, you have to select <Configuration->Alarm Out Configuration>. In this dialog, check the Enable … out boxes.

© 2010 Siemens AG 43

Page 44: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Clock SynchronizationProper clock synchronization is mandatory for SDH systems. You need at least one external clock source (PRC) for your network. In case you don't have one, you might consider taking the clock from a PDH signal. By default, the hiT70xx uses the internal oscillator in free running mode. To make the multiplexer using an external timing source, you have to add one in <Configuration->Synchronization Management>.

© 2010 Siemens AG 44

Page 45: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Hover the mouse over the port that you want to use as clock source and select “Add” in the context menu.

© 2010 Siemens AG 45

Page 46: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Once a clock source is defined, you can change some parameters. Most important is the priority: lower values outplay higher values. The hiT 70xx always selects the clock with the best quality, but when several equal clocks are available, then the priority decides.

© 2010 Siemens AG 46

Page 47: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

The hiT is still working in free running mode. Press the <System Clock> button in the “Synchronization Management” dialog, choose “AutoSelection” and activate this new setting by pressing “Set Mode”.

© 2010 Siemens AG 47

Page 48: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

ProtectionThe hiT offers different methods of protection: hardware protection and path protection. If you have e.g. a second cross connector card for hardware protection, the active one is identified by the “ACT” LED. You can manually switch the active card by selecting <Configure->CC 1+1 Protection>. When you select “Manual Switch” and the selected card becomes faulty, the multiplexer will still switch over to the other card. However, when you select “Forced Switch”, the automatic switchover is deactivated.

© 2010 Siemens AG 48

Page 49: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

In order to get hardware protection for E1 cards, you have to define an equipment protection group: Select <Configuration->1:N Equipment Protection Management> and create a new group.

© 2010 Siemens AG 49

Page 50: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

After refreshing the main window you get a list of the defined protection groups.

© 2010 Siemens AG 50

Page 51: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Path protection comes in different flavors. One is MSP (Multiplexer Section Protection). MSP can be activated by selecting <Configuration->MSP Management> and then pressing the “Create” button.

© 2010 Siemens AG 51

Page 52: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

After refreshing the main window you get a list of the defined protection groups.

Note: You have to set up MSP on the remote mutiplexer as well.

© 2010 Siemens AG 52

Page 53: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Another method is MS-SPRing (Multiplexer Section Shared Protection Ring). MS-SPRing allows to use the bandwidth, that is used for protection, for traffic as well, as long as to protection is active.

To set up MS-SPRing, select <Configuration->MS-SPRing Management> and press the “Create” button.

Enter a name for the new ring, enter the number of network elements in the protected ring and click “OK”.

© 2010 Siemens AG 53

Page 54: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

A window showing the ring opens. Left click on each NE and enter its IP address (start with the local NEs address as No. 0).

© 2010 Siemens AG 54

Page 55: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Left click on each link (east and west) and enter the slot and port of the corresponding interface. In the peer link area, enter the slot and port of the remote NE.

© 2010 Siemens AG 55

Page 56: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

When all links are green, click “OK”

© 2010 Siemens AG 56

Page 57: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Now, double-click on the new entry (or select it and press “Property”)

© 2010 Siemens AG 57

Page 58: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

this opens the property window of this ring. Press “Enable” to activate protection.

Repeat adding MS-SPRing on all participating NEs!

© 2010 Siemens AG 58

Page 59: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

Saving / Restoring the MIBSelect NE MIB Management->To Local Folder. The MIB Management dialog allows you to upload the current configuration to your PC, to download a previously saved configuration to the hiT and to erase the current configuration (this option is inactive until you've uploaded the current configuration to your computer)

After uploading, find your file in <C:\Program Files\Nokia Siemens Networks\TNMS CT\NStar\SURPASS hiT 7060 4.2\build\ftproot\mibs\X.X.X.X> where X.X.X.X is the IP address of your hiT.

© 2010 Siemens AG 59

Page 60: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

When restoring a previously saved configuration, do not forget to press the “Switch NE MIB” button in order to activate the downloaded file. Also, a warm or cold reboot of the multiplexer will be necessary in order to activate the new settings.

© 2010 Siemens AG 60

Page 61: HiT70xx Commissioning Guide

Surpass hiT 7025 and 7060 Commissioning Guide

LP-201 IP Phone SetupThis setup assumes a simple peer to peer configuration without gatekeeper (gateway to traditional telephone network )

After booting the IP phone, enter the “System Configuration” by pressing one of the arrow keys and then the “OK” key. Password is “x” (press the transfer button + '9' + '9'). Enter “Connect Configuration” (by pressing “OK”) and enter IP address and subnet mask. After that, reboot the telephone.

Connect phone via Ethernet cable to PC and log in via web-browser, user “root” and no password. Enter the following settings:

– in “Network Configure”: verify again IP address and subnet mask.

– in “H232 Configure”: set to Peer-to-Peer mode and enter phone numbers of the other phones (registered E.164 numbers)

– in “Phone Book”: Enter IP address and phone number for each phone.

In order to active the changes you have to reboot the telephone.