hilb type - ctae.co.thctae.co.th/files/products/hyundai heavy industry product/hyundai hilb... ·...

16

Upload: dotu

Post on 24-Aug-2019

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer
Page 2: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

HiLB Type

Load Break Switch

HighBreakingCapacity

CompactSize

HydraulicSystem

ImprovedSafety

LightWeight

EarthingSwitch

H Y U N D A I H i L B T Y P E L O A D B R E A K S W I T C H■ ■ ■

Page 3: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

Features 4

Structure 4

Ratings 5

Order Information 5

Accessories 6

Fuse Selection 7

Dimensions 8

Circuit Diagram 12

Installation and Operation 14

Hyundai HiLB type Load Break Switch offers excellent features to switch on/off the load current in

medium voltage system with improved safety.

Reliable switching performance is assured with the channel-

shaped main blade receiving minimal damage.

The hydraulic type manual operating device drives geared

method mechanism to ensure accurate operation, and the

operating device can be installed at the customer’s

convenient location.

We Build a Better Future!

C O N T E N T S

Page 4: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

LBS4◀ HiLB Type

Structure

Shunt

Terminal Block (Motor Type)

Oil Pressure Unit

Puffer Piston

Oil Cylinder

Fuse Checker

Manual Operating Device

Aux. Contact

Trip Rod

Earthing Bolt

Insulation Rod

Fuse

Frame

Operating Mechanism

Blade

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

4

2

1

8

14

5

11

6

7

10

9

12

13

15 3

Features

Light weight and compact size make installation easier.

A hydraulic system is used for the remote electric or

manual operation, providing the customer with easy

switch operation and installation.

The flexible oil hose made of soft PVC material allows

the MOD(Manual Operating Device) to be installed on

any position either the left or right hand side

If any fuse is removed or melted, the switch contact will

open automatically. Also, if every fuse is not installed, the

switch cannot be closed by mechanical interock.

It prevents phase failure to increase safety.

By using the Air Puffer Free-Piston method, compressed

air is sprayed through a nozzle to extinguish the arc.

This keeps the main blade safe from damage and ensures

reliable interruption preformance. A channel shaped blade

is used to enhance mechanical strength and ensure

excellent electrical characteristics during closing operations.

The unique and exclusive design of the LBS includes a Earthing Switch that will discharge any current from the cable.

The LBS can be interlocked with a Earthing Switch to prevent the system from accidents.

Light, Compact Design Improved Safety Features

Advanced Interruption System

Hydraulic Remote Control

Free Installation of the MOD

Earthing Switch

Page 5: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

5◀Load Break Switch

Model

Rated Voltage (kV)

Rated Current (A)

Switch Class (IEC)

Poles

Rated Frequency (Hz)

Rated Short-Time Current-Resistance

Rated Short-Circuit Making Current (peak)

HiLB06-SE HiLB06-FE HiLB06-EE HiLB06-AEHiLB06-SM HiLB06-FM HiLB06-AMHiLB06-EM

-

49

-

2

53

-

67

-

2

71

500

6.3-63

2

66 70

500

6.3-63

2

83 88

24

630

E1, M1

3

50/60

20kA/1sec

52

50kV, 1min

60kV, 1min

125kVp

145kVp

10 times

20 times

10 times

10 times

10 times

10 times

1,000 times

1.5

IEC60265-1, IEC62271-105, IEC60282-1, KSC4615, IEC62271-102(ES)

CommercialFrequencyVoltage-Resistant

ElectroencephaloImpulse Voltage-Resistance

LoadCurrent

Loop Current

CableChargingCurrent

LineChargingCurrent

Inter-Earth

Inter-Polarity

Inter-Earth

Inter-Polarity

630A

31.5A

630A

16A

4.8A

1.5A

CurrentBreak Time

No Load Break Times

Rated Transition Current (A)

Fuse Rating (Attach type) (A)

Rated Control Current (A)

Manual Operation Cable Length (m)

Weight (kg)

Applied Standard

Ratings

Model Type

ILB 06

Frame Size06HiLB 630AF

F

Combination TypeS

F

E

A

Standardwith FuseHolderwith EarthingSwitchwith FuseHolder &EarthingSwitch

E

Operating Method

ME

ManualMotor

0

Control Voltage01256

NoneAC 110VAC 220VDC 110VDC 220V

6

Rating Current6 630A

AccessoriesC12345T

Counter1a1b2a2b3a3b4a4bNon-standardShunt

S0

Fuse Holder 00S0

NoneSingle

CA

Order Information

※ - If you choose motor (operating method), you must select 1, 2, 5, or 6 (Control voltage)- If you choose manual (operating method), without control circuit, you can only select 0 (Control voltage)

- -

Page 6: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

LBS6◀ HiLB Type

Standard Order Code

Manual Operation

LBS L1

Motor Operation,DC 110V

ILB06 SM06 00ILB06 FM06 S0ILB06 EM06 00ILB06 AM06 S0ILB06 SE56 00ILB06 FE56 S0ILB06 EE56 00ILB06 AE56 S0

Model Specification Category

630A, Standard Type630A, with Single Fuse Holder630A, with Earthing Switch630A, with Single Fuse Holder & Earthing Switch630A, Standard Type630A, with Single Fuse Holder630A, with Earthing Switch630A, with Single Fuse Holder & Earthing Switch

Order Information

Accessories

◆ The earthing switch prevents the LBS from

mal-insertions between the LBS and the mechanical

interlock. It is designed to remove charged currents

during maintenance.

◆ The fuse trip device works automatically when a fuse

is broken (cut) due to short circuit or overcurrent. It is

quick and accurate.

◆ The counter displays the operation count to 5 digits.

(Optional)

◆ A hydraulic system is used for the remote electric or

manual operation. It offers the customer easy switch

operation and installation.

Hydraulic Remote ControlEarthing Switch

Fuse Trip Device Counter

Page 7: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

7◀

Fuse Selection

10

4

10

3

S 10

2

10

1 10

11

02

10

31

04

10

52

22

33

33

44

44

55

55

66

66

2A

88

88

10

0

10

-1 8 6 5 4 3 2

10

-2

63A50A40A

25A

20A

16A

10A

6.3A

31.5A

Time current characteristics for HV-back up fuse links 6.3-160A

Load Break Switch

24/25.8kV Fuse Specification

6.310162025

31.5405063

40 5×In24

Rated Voltage(kV)

Rated Current(A)

Rated BreakingCurrent

(kA)

Min. BreakingCurrent

(A)

Dimension(mm)

24/25.8kV Fuse Selection Table

Volt.TR(kVA)

24kV

30

6A

60

6A

75

10A

100

10A

150

16A

250

16A

350

16A

500

25A

1000

40A

1500

63A

2000

63A

53

442

Page 8: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

LBS8◀ HiLB Type

Dimensions

54

8

351

672

448

358

448 51

3

25

125

20

40

300

Ø14

800

850

300125

25

350

43Ground Bolt M10

55Auxiliary Terminal

Block (optional)

MountingHole 4-Ø14

(Unit: mm)

HiLB06-SM Type

672

5475

3

8

351

358

513

753

25800

850

25

55

125

350

300

20

300

40

325

23

125

Ø14

MountingHole 6-Ø14

Ground Bolt M10

Auxiliary Terminal Block (optional)

(Unit: mm)

HiLB06-SE Type (with Earthing Switch)

Page 9: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

9◀Load Break Switch

351

54

672

8

887

25

55

MountingHole 8-Ø14

990

887

7537

535

0

850

800

300

20

300125

Ø14

40

25

125

49358

32Shunt

(optional)

Ground Bolt M10

Auxiliary Terminal

Block (optional)

(Unit: mm)

HiLB06-FM Type (with Fuse)

672

8

351

5488

749

990

358

125

25

30040

850

800

125

25

300

55

887

7535

0

20

3237

5

Ø14

MountingHole 8-Ø14

Shunt(optional)

Ground Bolt M10

Auxiliary Terminal

Block (optional)

(Unit: mm)

HiLB06-AM Type (with Fuse and Earthing Switch)

Page 10: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

LBS10◀ HiLB Type

Dimensions

(Unit: mm)

LBS Manual Operating Device Installation Dimension (LBS, Type: SP-1)

LBS Manual Operating Device Installation Dimension (LBS with Earthing Switch, Type: SP-2)

Manual OperatingDevice

Mounting Plate

Frame

149 15

186.5 MountingHole 3-Ø9

2020

2525

Mounting Plate

Panel Door

L

35。

5。

75

68

Ø12

2-R8

5590

15

22.5

20D

eter

min

ded

by

the

Dis

tanc

e L

Panel Cutting

Ope

ratin

g A

ngle

40。

ManualOperating

Device

Mounting Plate

Frame

For EarthingSwitchFor LBS

(Unit: mm)

※ To minimize panel cutting, we reduced the distance between the panel door and the frame.

75

186.5MountingHole 3-Ø91585 64

2525

2020

5。35。

68L

Ø12

854-R8

Ope

ratin

g A

ngle

40。

15

90 5520

22.5

Det

erm

inde

d by

th

e D

ista

nce

L

Panel Cutting

Mounting Plate

Panel Door

Page 11: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

11◀Load Break Switch

(Unit: mm)

(Unit: mm)

Motor Operating Type (LBS, Type: SP-1)

Motor Operating Type (LBS with Earthing Switch, Type: SP-2)

※ To minimize panel cutting, we reduced the distance between the panel door and the frame.

Manual OperatingDevice

Mounting Plate

Frame

2020

2525

15MountingHole 3-Ø9

75

68L

Ø12

5。35。

5515

90

8222.5

119.5

Det

erm

inde

d by

th

e D

ista

nce

L

Panel Cutting

20

2-R8

Ope

ratin

g A

ngle

40。

Mounting Plate

Panel Door

75

15

2020

2525

L 68

Ø12

35。

5。

22.5 45

5515

20

90

186.5

Det

erm

inde

d by

th

e D

ista

nce

L

454-R8

104 MountingHole 3-Ø9

Panel Cutting

Ope

ratin

g A

ngle

40。

Mounting Plate

Panel Door

For EarthingSwith

For LBS

Manual OperatingDevice

Mounting Plate

Frame

Page 12: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

LBS12◀ HiLB Type

● P(+) - N(-): Power● P(+) - C(-): Close(On)● P(+) - T(-): Trip(Off)● LS1: Opening Limit Switch

● 1-8: ES Aux. Conact● 9-16: Aux. Contact● Y: Fuse Trip Ind. Terminal● LS2: Closing Contact Limit

M : Motor

RC : Closing Aux. Relay

TC : Trip Coil (Shunt)

RO : Opening Aux. Relay

G : Green Lamp

Y : Yellow Lamp

R : Red Lamp

Circuit Diagram

◆ Standard (Motor Operating Type)

◆With Earthing Switch (Motor Operating Type)

PT.B N C T G

N

DC

110

V

RC RCRO

M

b2b1

(LBS)

R a1 a1 a2b1 a2 a1b2 a1 a2a2

(ES)

b1 b1

10

1

24

3 LS1

a1

8 6

7 5

RO

RC TC RO

4

3

b1 a2 b2

13

1412

119

16

15

a2a1 b1

2

1

6 8

5 7

G

P

FUSE 5A

P

P

T.B P N TC

DC

110

V

N

M

RC RC

FUSE 5A

P

b1 a2a1RGTC b2

b2

LBS Aux., S/W

TC

ON OFF

G R a1

RG

R a1 a1 b1 b1 a2 a2

b1 a2 b2 a2a1 b1

ES Aux., S/W

a2a1

b2

b1 b2

13

4 2

RC TC

57

8 6 14

13119

10 12

15

16

ON OFF G R LBS Aux., S/W

Page 13: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

13◀Load Break Switch

● P(+) - N(-): Power● P(+) - C(-): Close(On)● P(+) - T(-): Trip(Off)● LS1: Opening Limit Switch

● 1-8: ES Aux. Conact● 9-16: Aux. Contact● Y: Fuse Trip Ind. Terminal● LS2: Closing Contact Limit

M : Motor

RC : Closing Aux. Relay

TC : Trip Coil (Shunt)

RO : Opening Aux. Relay

G : Green Lamp

Y : Yellow Lamp

R : Red Lamp

◆With Fuse (Motor Operating Type)

◆With Fuse and Earthing Switch (Motor Operating Type)

RO

LS1

(LBS)

a1T.B P N C T G R a1Y

N

DC

110

V

4

3

2

1

RCRO

M

RC

RC TC RO

4

3

CP

T.B

P

FUSE 5A

P C T

ON OFF

TNP C G R Y a1

DC

110

V

N

M

3

4

RC

FUSE 5A

RC RC

P

ON

a1a2b1b1 a2 b2 b2

(ES)

a2a1 a2 b1 b1

8

7

6

5

a1 b1 a2 b2

11

1210

9

14 16

13 15

LS3

a1 a2 b1

7

82 6

1 5

b2a2a1 b1YRGT

G R Y

RG Y

a1 b1 a2 b2

LBS Aux., S/W

a2a1 b1 a2b1 b2b2

a1 b1

ES Aux., S/W

a1 a2 b1

a2 b2

12

1171

2 8

TC

95

6 10

LS3

13 15

1614

LBS Aux., S/WOFF G YR

Page 14: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

LBS14◀ HiLB Type

Installation and Operation

CAUTION

※ An unbalanced panel may result in malfunctions. Screw the low part with washers or spacers.

Blade

TerminalPower Side

Frame

Mounting Hole

Manual operating device(LBS single type)

Manual operating device(LBS with earthing switch)

◆When installing a load break switch on a distribution board, carefully follow the specialized installation

instructions.

◆When installing a load break switch on a distribution board, insert the spring washers and plain washers

into the bolts and tighten it with designated torque. Be careful of forcible pressure or deformation.

◆ Any tension or pressure from a bus bar and etc. must not be applied to the main circuit terminals.

◆ The installer shall be responsible for maintaining the consistency of the phase arrangement.

◆ Classify the main circuit terminals into power side and load side.

Installation

◆ Pump the operating handle approximately 25 pumping cycles

after the manual operating device installed on the panel.

◆ Stop operations when the closing is complete in manual type.

◆ It will open after 5 pumping cycles.

◆ Stop operations when the opening is complete in manual type.

Manual Operating Type

External Structure

◆ Inspect the control power and circuit after the manual operating device is installed on the panel.

◆ The spring for an input is enlarged by turn exercise of the drive motor within 5-10 sec.

◆ The load break switch is opened via the shunt coil by supplying the specified control power.

◆ CLOSE/OPEN operations are hazardous, follow all safety guidelines when operating to prevent accidents.

◆ LBS+with ES is only applied to manual type operation.

◆ The earthing switch is only closed when the LBS is open, the LBS is closed only when earthing switch is closed.

Motor Operating Type

To ensure product safety, the switch shouldonly be used after the frame is secured on alevel surface.Stand back from the switch when a fuse mustbe removed; the switch contact (blade) willopen automatically and may cause physicaldamage.Do not push down the moving plunger of theshunt coil (locate on the top left of the frame)in the closed contact position. It will also openthe switch contact.

Page 15: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

15◀Load Break Switch

※ Do ON/OFF operation on a level surface.

Terminal Power Side

Terminal Power Side

Vertical Installation

Horizontal Installation

Page 16: HiLB Type - ctae.co.thctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY PRODUCT/Hyundai HILB... · LBS 4 HiLB Type Structure Shunt Terminal Block (Motor Type) Oil Pressure Unit Puffer

HH

IS-W

C-LE

-B46-01, 2008.10 D

esigned by Design K

orea

Head Office 1, Jeonha-dong, Dong-gu, Ulsan, Korea Tel. 82-52-202-8101~8 Fax 82-52-202-8100

Seoul 140-2, Gye-dong, Jongno-gu, Seoul, Korea(Sales & Marketing) Tel. 82-2-746-7589, 7510 Fax 82-2-746-7647

Orlando 3452 Lake Lynda Drive, Suite 170, Orlando, Florida 32817, U.S.A. Tel: 1-407-249-7350 Fax: 1-407-275-4940

New Jersey 300 Sylvan Avenue, Englewood Cliffs, NJ 07632, U.S.A. Tel: 1-201-816-0286 Fax: 1-201-816-4083

London 2nd Floor, The Triangle, 5-17 Hammersmith Grove, London, W6 0LG, UKTel: 44-20-8741-0501 Fax: 44-20-8741-5620

Tokyo 8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-cho, Chiyoda-gu, Tokyo, 100-0006, JapanTel: 81-3-3212-2076, 3215-7159 Fax: 81-3-3211-2093

Osaka I-Room 5th Fl. Nagahori-Plaza Bldg. 2-4-8, Minami Senba, Chuo-Ku, Osaka, Japan, 542-0081Tel: 81-6-6261-5766, 5767 Fax: 81-6-6261-5818

Dubai Unit 205, Level 2, Burj Dubai Square Building No. 4, Sheikh Zayed Road, P.O.Box 252458Tel: 971-4-425-7995 Fax: 971-4-425-7996

Sofia 1271, Sofia 41, Rojen Blvd., BulgariaTel: 359-2-803-3200 Fax: 359-2-803-3203

Yangzhong No. 9 Xiandai Road, Xinba Scientific and Technologic Zone, Yangzhong, Jiangsu, P.R.C. Zip: 212212, ChinaTel: 86-511-8842-0666, 0212 Fax: 86-511-8842-0668, 0231