high titers of multiple antibody isotypes against the sars-cov-2 … · 2020. 8. 15. · 65...

32
1 High titers of multiple antibody isotypes against the SARS-CoV-2 spike receptor-binding 1 domain and nucleoprotein associate with better neutralization. 2 3 Maria G. Noval 1† , Maria E. Kaczmarek 1† , Akiko Koide 2,3† , Bruno A. Rodriguez-Rodriguez 1† , Ping 4 Louie 4† , Takuya Tada 1† , Takamitsu Hattori 2,5 , Tatyana Panchenko 2 , Larizbeth A. Romero 5 , Kai 5 Wen Teng 2 , Andrew Bazley 5 , Maren de Vries 1 , Marie I. Samanovic 6 , Jeffrey N. Weiser 1 , Ioannis 6 Aifantis 2,4 , Joan Cangiarella 4 , Mark J. Mulligan 6 , Ludovic Desvignes 3,6,7 , Meike Dittmann 1 , 7 Nathaniel R. Landau 1 , Maria Aguero-Rosenfeld 4 , Shohei Koide 2,5* , and Kenneth A. Stapleford 1* 8 9 1 Department of Microbiology, NYU Grossman School of Medicine, New York, NY 10016 10 2 Perlmutter Cancer Center, NYU Langone Health, New York, NY 10016 11 3 Department of Medicine, NYU Grossman School of Medicine, New York, NY 10016 12 4 Department of Pathology, NYU Grossman School of Medicine, New York, NY 10016 13 5 Department of Biochemistry and Pharmacology, NYU Grossman School of Medicine, New York, 14 NY 10016 15 6 New York University Langone Vaccine Center and New York University Grossman School of 16 Medicine, New York, NY 10016. 17 7 Office of Science and Research, NYU Langone Health, New York, NY 10016 18 19 Running title: SARS-CoV-2 antibody response in healthcare workers. 20 21 Contributed equally to this work. 22 *Corresponding authors. 23 (which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprint this version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353 doi: bioRxiv preprint

Upload: others

Post on 24-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

1

High titers of multiple antibody isotypes against the SARS-CoV-2 spike receptor-binding 1

domain and nucleoprotein associate with better neutralization. 2

3

Maria G. Noval1†, Maria E. Kaczmarek1†, Akiko Koide2,3†, Bruno A. Rodriguez-Rodriguez1†, Ping 4

Louie4†, Takuya Tada1†, Takamitsu Hattori2,5, Tatyana Panchenko2, Larizbeth A. Romero5, Kai 5

Wen Teng2, Andrew Bazley5, Maren de Vries1, Marie I. Samanovic6, Jeffrey N. Weiser1, Ioannis 6

Aifantis2,4, Joan Cangiarella4, Mark J. Mulligan6, Ludovic Desvignes3,6,7, Meike Dittmann1, 7

Nathaniel R. Landau1, Maria Aguero-Rosenfeld4, Shohei Koide2,5*, and Kenneth A. Stapleford1* 8

9

1Department of Microbiology, NYU Grossman School of Medicine, New York, NY 10016 10

2Perlmutter Cancer Center, NYU Langone Health, New York, NY 10016 11

3Department of Medicine, NYU Grossman School of Medicine, New York, NY 10016 12

4Department of Pathology, NYU Grossman School of Medicine, New York, NY 10016 13

5Department of Biochemistry and Pharmacology, NYU Grossman School of Medicine, New York, 14

NY 10016 15

6New York University Langone Vaccine Center and New York University Grossman School of 16

Medicine, New York, NY 10016. 17

7Office of Science and Research, NYU Langone Health, New York, NY 10016 18

19

Running title: SARS-CoV-2 antibody response in healthcare workers. 20

21

†Contributed equally to this work. 22

*Corresponding authors. 23

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 2: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

2

Abstract 24

Understanding antibody responses to SARS-CoV-2 is indispensable for the development of 25

containment measures to overcome the current COVID-19 pandemic. Here, we determine the 26

ability of sera from 101 recovered healthcare workers to neutralize both authentic SARS-CoV-2 27

and SARS-CoV-2 pseudotyped virus and address their antibody titers against SARS-CoV-2 28

nucleoprotein and spike receptor-binding domain. Interestingly, the majority of individuals have 29

low neutralization capacity and only 6% of the healthcare workers showed high neutralizing titers 30

against both authentic SARS-CoV-2 virus and the pseudotyped virus. We found the antibody 31

response to SARS-CoV-2 infection generates antigen-specific isotypes as well as a diverse 32

combination of antibody isotypes, with high titers of IgG, IgM and IgA against both antigens 33

correlating with neutralization capacity. Importantly, we found that neutralization correlated with 34

antibody titers as quantified by ELISA. This suggests that an ELISA assay can be used to 35

determine seroneutralization potential. Altogether, our work provides a snapshot of the SARS-36

CoV-2 neutralizing antibody response in recovered healthcare workers and provides evidence that 37

possessing multiple antibody isotypes may play an important role in SARS-CoV-2 neutralization. 38

39

Keywords: SARS-CoV-2, COVID-19, antibody, isotype, neutralization. 40

41

42

43

44

45

46

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 3: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

3

Introduction 47

The novel coronavirus, Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-48

2), has rapidly spread across the globe, leading to Coronavirus Disease 2019 (COVID-19), 49

devastating mortality, and significant impacts on our way of life. One question that still remains is 50

whether those infected by SARS-CoV-2 generate an immune response that will protect them from 51

reinfection1. Moreover, this question is particularly important for the development of a SARS-52

CoV-2 vaccine, as an effective vaccine would need to generate a potent neutralizing antibody 53

response and immunological memory to provide long-lasting protection2,3. Thus, it is essential that 54

we carefully study and document the neutralizing antibody responses in recovered individuals. 55

SARS-CoV-2 antibody testing is critical to understanding who has been infected and to 56

provide a picture of seroprevalence in a community4-9. However, while these tests are important 57

and provide a relative antibody titer, they are seen more as a “yes or no” type of answer to whether 58

an individual has been infected. Importantly, these tests do not provide information on whether the 59

SARS-CoV-2-specific antibodies present in serum are protective, including through virus 60

neutralization, and as such, a positive antibody test may give individuals a false sense of 61

“immunity” to the virus. 62

A number of studies have begun to unravel the antibody response to SARS-CoV-2 beyond 63

a simple “yes or no” answer 9-18. Here, we hypothesized that by examining the antibody profile in 64

patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization, 65

we would be able to identify specific signatures associated to effective SARS-CoV-2 66

neutralization. In this study, we obtained convalescent serum from 101 SARS-CoV-2 PCR-67

positive healthcare workers and performed a comprehensive analysis of neutralization of authentic 68

SARS-CoV-2 and a pseudotyped lentivirus as well as serum IgG, IgM, and IgA antibody titers to 69

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 4: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

4

the SARS-CoV-2 spike receptor-binding domain (RBD) and the nucleoprotein (N) (Fig. 1a). 70

Together, this study provides an in-depth look into the SARS-CoV-2 neutralizing antibody 71

response in recovered individuals and highlights the role of multiple antibody isotypes in the 72

development of a potent neutralizing antibody response. 73

74

Methods 75

Serum samples. Serum was collected from 101 healthcare workers from NYU Langone who had 76

laboratory evidence of COVID-19 (PCR-positive) and were at least 21-28 days post symptoms or 77

PCR test. Healthy control sera were collected from patients through the NYU Vaccine Center. All 78

patients gave written consent and all samples were deidentified for this study under IRB #i20-79

00595 (SARS-CoV-2 infected) and IRB #s18-02037 (healthy controls). 80

Plasmids For pseudotyped virus generation: To construct the SARS-CoV-2 SD19 expression 81

vector pcCOV2-D19.S, a codon-optimized DNA sequence was synthesized encoding the SARS-82

CoV-2 Spike (Wuhan-Hu-1/2019). An amplicon was amplified encoding the S protein with a 19 83

amino acid truncation of the cytoplasmic tail using primers containing flanking 5’-KpnI and 3’-84

XhoI sites and cloned into pcDNA6 (Invitrogen, Inc.). To construct the ACE2 expression vector 85

pLenti.ACE2-HA, the ACE2 coding sequence was amplified from an ACE2 cDNA (Origene Inc) 86

using primers with flanking 5’-XbaI and 3’-SalI sites and cloned into pLenti.CMV.GFP.puro. For 87

RBD ELISA: The nucleotide sequence of the RBD of SARS-CoV-2 isolate Wuhan-Hu-1 (residues 88

328-531) was obtained from a GenBank entry MN908947.3. A codon-optimized gene encoding 89

the RBD with a hexa-histidine tag (His6-tag) and biotinylation tag (Avi-tag) at the C terminus was 90

synthesized (Integrated DNA Technologies) and cloned into the pBCAG mammalian expression 91

vector. 92

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 5: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

5

Cells and virus. Vero E6 cells (ATCC CRL-1586) were maintained in Dulbecco’s Modified 93

Eagle’s Medium (DMEM, Corning) supplemented with 10% fetal bovine serum (FBS, Atlanta 94

Biologics) and 1% nonessential amino acids (NEAA, Corning). Human embryonic kidney (HEK) 95

293T cells were maintained in DMEM supplemented with 10% FBS, and 1% 96

penicillin/streptomycin (P/S). To generate 293T stably expressing ACE2 (ACE2-293T cells), 97

293T cells were transfected with pLenti.ACE2-HA DNA by lipofection with lipofectamine 2000 98

(Invitrogen). After 2 days, the cells were selected in DMEM supplemented with 10% FBS, 1% 99

P/S, and 1 µg/ml of puromycin. Single cell clones were expanded and analyzed by flow cytometry 100

for ACE2 expression and a single clone was chosen for subsequent use. Expi293T cells (Thermo 101

Fisher) were maintained in Expi293 Expression Medium (Thermo Fisher). All cells were 102

maintained at 37oC with 5% CO2 and confirmed mycoplasma free. 103

SARS-CoV-2, isolate USA-WA1/202019 (BEI resources # NR52281, a gift from Dr. Mark 104

Mulligan at the NYU Langone Vaccine Center) was amplified once in Vero E6 cells (P1 from the 105

original BEI stock). Briefly, 90-95% confluent T175 flask (Thomas Scientific) of Vero E6 (1x107 106

cells) was infected with 10 μL of the BEI stock in 3 mL of infection media (DMEM, 2% FBS, 1% 107

NEAA, and 10 mM HEPES, pH 7.0) for 1 hour. After 1 hour, 15 ml of infection media was added 108

to the inoculum and cells were incubated 72 hrs at 37 °C and 5% CO2. After 72 hrs, the supernatant 109

was collected and the monolayer was frozen and thawed once. Both supernatant and cellular 110

fractions were combined, centrifuged for 5 min at 1200 rpm, and filtered using a 0.22 μm Steriflip 111

(Millipore). Viral titers were determined by plaque assay in Vero E6 cells. In brief, 220,000 Vero 112

E6 cells/well were seeded in a 24 well plate, 24 hrs before infection. Ten-fold dilutions of the virus 113

in DMEM were added to the Vero E6 monolayers for 1 hour at 37 °C. Following incubation, cells 114

were overlaid with 0.8% agarose in DMEM containing 2% FBS and incubated at 37 °C for 72 hrs. 115

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 6: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

6

The cells were fixed with 10% formalin, the agarose plug removed, and plaques visualized by 116

crystal violet staining. All experiments with authentic SARS-CoV-2 were conducted in the NYU 117

Grossman School of Medicine ABSL3 facility. 118

Pseudotyped virus preparation. Pseudotyped virus was produced by calcium phosphate 119

cotransfection of 293T cells with pMDL, plenti.GFP-NLuc, pcSARS-CoV-2-SD19 and pcRev at a 120

ratio of 4:3:4:1. The supernatant was harvested 2 days post-transfection, passed through an 0.22 121

µm filter and then pelleted by ultracentrifugation for 90 min at 30,000 rpm in an SW40.1 rotor. 122

The pellet was resuspended in 1/10th the original volume of DMEM supplemented with 10% FBS 123

and frozen at -80°C in aliquots. 124

SARS-CoV-2 neutralization assay. Vero E6 cells (30,400 cells/well) were seeded in a 96 well 125

plate 24 hrs before infection so that a monolayer was present the following day. Serum samples 126

from COVID-19 convalescent individuals and healthy donors were two-fold serially diluted 127

(spanning from 1:10 to 1:10,240) in DMEM (Corning), 1% NEAA (Corning) and 10 mM HEPES 128

(Gibco). Diluted serum samples were mixed 1:1 (vol/vol) with SARS-CoV-2 virus (6.8 x 103 129

PFU/ml), and incubated 1 h at 37 °C. During the incubation period, Vero E6 monolayers were 130

washed once with DMEM (Corning) to remove any serum present in the media that could interfere 131

with the assay. After incubation, 100 μl of the serum:SARS-CoV-2 mixtures were added to the 132

Vero E6 monolayers, and cells were incubated at 37°C. Cells were monitored every day for 133

cytopathic effects (CPE) induced by viral infection, and at 5 days post infection cells were fixed 134

in 10% formalin solution (Fisher Scientific) for 1 hr. Cells were then stained by adding 50 µl 135

crystal violet/well and incubated for 30 min. Each well was scored as “0” if there was no monolayer 136

left, “0.5” if there was some monolayer and the well was clearly infected, or “1” if the monolayer 137

was intact. The minimum inhibitory concentration (MIC) was defined as the minimal serum 138

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 7: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

7

dilution in which the cell monolayer was intact (score = 1). Each serum sample was measured in 139

technical duplicates. 140

Pseudotype virus neutralization assay. To determine neutralizing serum titers, ACE2-293T cells 141

were plated in 96 well tissue culture dishes at 10,000 cells/well. The following day, 2-fold dilutions 142

of the donor sera were made in culture medium spanning a range from 1:10 to 1:10240. Each 143

dilution (50 μl) was mixed with 5 μl SARS-CoV-2 SΔ19 lentiviral pseudotype. The mixtures were 144

incubated for 30 min at room temperature and then added to the plated ACE-2 293T cells. The 145

plates were cultured for two days at 37°C with 5% CO2 after which the supernatant was removed 146

and replaced with 50 μl Nano-Glo Luciferase Substrate (Promega, Inc.). Light emission was 147

measured in an Envision 2103 Multi-label plate reader (PerkinElmer, Inc.). 148

SARS-CoV-2 Nucleoprotein ELISA. Serum IgG, IgA, and IgM antibodies to the SARS-CoV-2 149

nucleoprotein were tested using the SARS-CoV-2 IgG, IgA and IgM ELISA kits manufactured by 150

Virotech Diagnostics GmbH for Gold Standard Diagnostics (Davis, CA) following the 151

manufacturer’s instructions. For the detection of IgG and IgA, serum samples were diluted 1:100 152

in dilution buffer and for IgM, serum samples were diluted 1:101 in RF-Adsorption dilution buffer 153

mixture and incubated at room temperature for 15 min before being added to the wells. Results are 154

reported qualitatively as negative (<9.0 units), equivocal (9.0-11.0 units), and positive (>11.0 155

units). 156

SARS-CoV-2 spike receptor-binding domain (RBD) purification and ELISA. The Expi293F 157

cells (Thermo Fisher) were transiently transfected with the expression vector using the 158

ExpiFectamineTM 293 Transfection Kit (Thermo Fisher, A14524)) and the Expi293 Expression 159

Medium (Thermo Fisher, A14351). The transfected cells were cultured at 37 °C with 8% CO2 for 160

7 days. The culture supernatant was harvested by centrifugation, supplemented with protease 161

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 8: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

8

inhibitors and clarified by further centrifugation at 8,000 rpm for 20 min and filtration through a 162

0.22 µm filter. The supernatants were dialyzed into 20 mM sodium phosphate pH 7.4 with 500 163

mM sodium chloride and the recombinant RBD was purified by immobilized metal ion affinity 164

chromatography (IMAC) using a HisTrap excel column (GE Healthcare). The purified protein was 165

biotinylated using the E. coli BirA enzyme produced in house in the presence of 10 mM ATP and 166

0.5 mM biotin. The RBD protein was purified by IMAC and dialyzed against PBS and stored at -167

80 °C. High purity of the purified protein was confirmed using SDS-PAGE, and analysis by size 168

exclusion chromatography using a Superdex 75 10/300 Increase column (GE Healthcare), which 169

showed a single, monodisperse peak consistent with its molecular mass (Extended Data Fig. 1A 170

and B). 171

For the ELISA, the wells of 384-well ELISA plates (NUNC Maxisort cat# 464718) were 172

coated with 15 µl of 4 µg/ml neutravidin (ThermoFisher cat # 31000) for one hour at room 173

temperature (R.T.) in a humidified chamber. The wells were washed with 100 µl PBST (PBS 174

containing 0.1 % Tween 20) (ThermoFisher, cat# BP337-500) three times using a BioTek 405TS 175

plate washer housed in a BSL-2 biosafety cabinet. The wells were blocked with 0.5 % BSA 176

(Gemini Bio cat# 700-100P, skim milk was not used for blocking because milk can contain biotin 177

that would inhibit antigen immobilization) in PBS overnight at 4 °C. After removing the blocking 178

buffer, 15 µl of 20 nM RBD-His6-Avi-biotin in PBS was added to each well using a Mantis 179

dispenser (Formulatrix). The plates were incubated at R.T. in a humidified chamber for 20 min, 180

and the wells were washed with 100 µl PBST three times using the plate washer. The wells were 181

further blocked with 15 µl of 10 µM biotin in 3% skim milk in PBST (Sigma, cat# 1.15363.0500) 182

for ten min at R.T. in order to block unsaturated neutravidin. 183

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 9: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

9

Serum samples were heat-treated at 56°C for one hour9 and diluted 158-fold in 1% skim 184

milk in PBST and placed in a 96-well polypropylene plate (ThermoFisher, cat # AB-0796), which 185

served as a master plate. The following sample handling was performed using a Hudson SOLO 186

liquid handler housed in a BSL-2 biosafety cabinet. Twelve microliters of diluted serum were 187

transferred per well of an RBD-immobilized 384-well plate after removing the biotin solution. To 188

prepare 500-fold diluted samples, 8.22 µl of the diluent (1 % skim milk in PBST) was first 189

dispensed into a well to which 3.78 µl of diluted serum from the master plate was added. After 2 190

hours of incubation at R.T., the plate was washed with PBST three times using the plate washer. 191

15 µl of secondary antibody (anti human Fab-HRP: Jackson ImmunoResearch, cat# 109-035-097; 192

anti human IgG-HRP: Sigma, cat# A6029-1ML; anti human IgM-HRP: Jackson ImmunoResearch, 193

cat# 109-035-129; and anti-human IgA-HRP: Jackson ImmunoResearch, cat# 109-035-011; 194

x1/5000 diluted in 1 % milk in PBST) was added using the Mantis dispenser and incubated for one 195

hour at R.T. After washing the plate with PBST three times and then with PBS three times, 25 µl 196

of the substrate (SIGMAFAST™ OPD; Sigma P9187-50SET) was added into the wells using the 197

Mantis dispenser. Subsequently, the stop solution (25 µl of 2 M HCl) was added using the Mantis 198

dispenser. The dispenser was programmed in such a way that the reaction in each well was stopped 199

after 10 min. Absorbance at 490 nm was measured using a BioTek Epoch 2 plate reader. All 200

samples were analyzed two independent times to identify outliers. Those yielding inconsistent 201

results in both assays were excluded from analysis (Sample 76 and 86, Extended Data Table 1). 202

Thresholds were determined comparing the 101 SARS-CoV-2 PCR positive samples at two 203

dilutions 1/158 and 1/500 and compared with 43 SARS-CoV-2 PCR negative individuals. The 204

cutoff values were defined as the mean plus three times the standard deviation (SD) of the negative 205

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 10: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

10

control samples. Results were reported as positive if the values are > 1.091 for IgG, > 0.256 for 206

IgA and > 0.694 for IgM (Extended Data Fig. 1C). 207

Data analysis and statistics. All experiments were performed in technical duplicates and data 208

analysis and statistics were performed using GraphPad Prism (Version 8.4.3), R Studio (Version 209

1.2.5001), and R (Version 3.6.3). 210

Data availability. Data that supports all figures, extended data, and analysis is found in Extended 211

Data Table 1. 212

213

214

215

216

217

218

219

220

221

222

223

224

225

226

227

228

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 11: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

11

Results 229

SARS-CoV-2 seroneutralization capacity is low in the majority of individuals. 230

To better understand the human SARS-CoV-2 neutralizing antibody response in 231

convalescent patients, we obtained serum from 101 COVID-19-recovered New York City 232

healthcare workers who had experienced symptoms and had tested positive (by PCR testing) for 233

SARS-CoV-2 in March 2020 (Fig. 1a and Extended Data Table 1). To begin, we assessed how 234

well each individual’s serum was able to neutralize both authentic SARS-CoV-2 (isolate USA 235

WA01/2020), and a lentiviral pseudotyped virus bearing the SARS-CoV-2 Spike protein 236

(pseudotyped virus) in vitro. Pseudotyped viruses are a safe alternative to authentic virus assays20, 237

and can therefore be employed by a greater number of research institutes and clinical laboratories 238

to assess neutralization of convalescent serum. However, several studies have shown differences 239

in sensitivity between neutralization of authentic SARS-CoV-2 and specific pseudotyped 240

viruses21,22. Thus, we set out to determine serum neutralization capacity using both our in-house 241

lentiviral pseudotyped virus and the WA01/2020 strain of SARS-CoV-2. 242

For the neutralization assays performed with authentic SARS-CoV-2 virus we determined 243

the minimum inhibitory concentration (MIC), calculated as the minimum serum dilution at which 244

serum is fully-protective (Extended Data Table 1). For the neutralization experiments performed 245

with the pseudotyped virus, we used a reporter pseudotyped virus expressing luciferase which 246

allows for the calculation of the IC90 and the midpoint transition (IC50) (Extended Data Fig. 2 and 247

Extended Data Table 1). Using these systems, we found that neutralization of the authentic 248

SARS-CoV-2 and the pseudotyped virus was positively correlated (Fig. 1b, R2 = 0.49, p<0.0001). 249

Moreover, the SARS-CoV-2 neutralizing antibody response could be broken into three categories 250

(Fig. 1c). Using 1/MIC and 1/IC90 we find the majority of infected individuals (~75%) had a low 251

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 12: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

12

neutralization capacity, roughly 20% of individuals had intermediate neutralization and only a 252

select few (~5-6%) had high neutralization of the authentic virus. When comparing pseudotyped 253

virus to authentic SARS-CoV-2 virus neutralization, there was no significant difference in the 254

proportion of individuals assigned as low or intermediate (Fig. 1c). In contrast, there is a significant 255

difference between the percentage of individuals deemed high neutralizers using authentic SARS-256

CoV-2 versus pseudotyped virus (Fig. 1c and d, p=0.02). These results validate the use of the 257

pseudotyped virus as an efficient alternative to determine the neutralizing potential of serum. But 258

they also suggests that authentic SARS-CoV-2 virus may be better able to detect potent 259

neutralizing serums, which has implications for the selection of donors for passive immunization 260

therapy. 261

Finally, because samples were collected from individuals at varying times post onset of 262

symptoms, it may be expected that the proportion of highly or moderately neutralizing sera would 263

decrease over time. However, we found that there was no particular pattern in this cohort. 264

Individuals with low, medium, and high neutralizing sera determined using authentic SARS-CoV-265

2 are found between 32 and 57 days (Fig. 1e). Together, these results show that at the time points 266

we analyzed (32-57 days post symptom onset), serum SARS-CoV-2 neutralizing antibody capacity 267

is low in most recovered individuals. 268

Human SARS-CoV-2 infection generates antigen-specific, multi-isotype antibody response. 269

Given the broad neutralization capacity observed in this cohort, we were interested in 270

examining the antibody profile of each individual. It is not uncommon that antibody responses are 271

skewed toward one or a few viral proteins10,23. If this is the case, using a single antigen may result 272

in a biased test that inadequately detects antibodies produced by convalescent individuals. Thus, 273

we quantified serum antibody IgG, IgA, and IgM titers by ELISA, focusing on antibodies 274

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 13: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

13

generated to two SARS-CoV-2 antigens (Extended Data Table 1). First, we used the Gold 275

Standard ELISA assay currently deployed at the Tisch Hospital Clinical Labs in New York City 276

which uses the nucleoprotein (N). Second, we developed an in-house ELISA for the SARS-CoV-277

2 Spike receptor-binding domain (RBD) (Extended Data Fig. 1). If antibody titers against Spike 278

RBD and N correlate, this suggests that individuals mount a uniform response to both these 279

antigens. A lack of correlation suggests that individuals mount a skewed response toward one of 280

these antigens preferentially. 281

When we compared the isotype responses to anti-RBD and anti-N directly, we found that 282

IgG correlated the strongest (R2 = 0.51) followed by IgA (R2 = 0.23) and IgM (R2 = 0.21) (Fig. 283

2a-c, left panels). The percentage of IgG and IgM positive individuals, as detected by reactivity 284

against RBD or N, was similar (Fig. 2a and b, right panels). Strikingly, the majority of individuals 285

with positive titers of IgA to the Spike RBD were largely IgA-negative for N (Fig. 2c, left panel). 286

This translated to a significant difference in IgA detection between the Gold Standard test and our 287

in-house ELISA (Fig. 2c, right panel, p = 2 x 10-16), and suggests that the IgA response is largely 288

skewed towards the Spike RBD in comparison to N (Fig. 2c). It is possible that days post symptom 289

onset plays a role in both serum antibody titers and the relative percentage of IgG, IgM and IgA 290

positive people. Within our cohort we observed no relationship between time post symptom onset 291

and antigen-specific antibody isotype titers (Extended Data Fig. 3), even finding IgM present at 292

50 days post infection (Extended Data Fig. 3B). Together these results suggest that the antibody 293

isotype response to SARS-CoV-2 may be antigen-specific, with IgA skewed towards the RBD. 294

SARS-CoV-2 neutralization best correlates with RBD antibody response. 295

To better understand how each antigen-specific antibody isotype correlated with 296

neutralization, we compared the ELISA assay antibody titers with virus neutralization. While all 297

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 14: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

14

anti-RBD isotype titers correlated similarly with the neutralization level of the authentic SARS-298

CoV-2 (R2 = 0.4786 – 0.5194) (Fig. 3a), we found that pseudotyped virus neutralization correlated 299

best with IgG titers (R2 = 0.4561) compared with IgA (R2 = 0.2556) or IgM (R2 = 0.2391) (Fig. 300

3b). One explanation for these findings may be that there are molecular differences in folding 301

between the RBD of the authentic virus, pseudotyped virus, and purified RBD such that they are 302

recognized differently by antibody isotypes in these assays24,25. Interestingly, with the exception 303

of anti-N IgG antibodies for the authentic virus (R2 = 0.5277; R2 = 0.255), other anti-N isotype 304

titers showed weaker correlations for either the authentic SARS-CoV-2 virus or the pseudotyped 305

virus (Extended Data Fig. 4). These data suggest that ELISA methods based on the RBD may 306

benefit from detection of additional isotypes, rendering them better suited as predictors of sera 307

neutralization. 308

Robust SARS-CoV-2 neutralization associates with high-titer, multi-isotype antibody 309

responses. 310

Next, we delineated what separates our highest neutralizers from the remainder of the 311

cohort using the data collected on antigen-specific antibody isotype titers. To do so, we employed 312

a holistic approach and compared the IgG, IgM and IgA titers for both anti-Spike RBD and anti-313

N antibodies against neutralizations level (Fig. 4a and b). This revealed that the highest overall 314

neutralizers (MIC higher or equal to 1/640) had higher titers of IgG, IgM and IgA raised against 315

both Spike RBD and N (Fig. 4a and b, red bar). The spike protein is the major determinant for 316

virus neutralization and resides on the outside of the viral particle, exposed to the immune 317

recognition. Consequently, we found stronger correlations between Spike-RBD isotypes compared 318

with N isotypes, when comparing each individual’s IgG, IgM or IgA (anti-Spike RBD and N) 319

against each other (Fig. 4c and d). However, in most cases the high neutralizers (red circles) had 320

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 15: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

15

the highest antibody titers for all isotypes (Fig. 4c and 4d). These data suggest that mounting a 321

robust antibody response, consisting of diverse isotypes, leads to efficient neutralization. 322

Recovered individuals have multiple combinations of anti-SARS-CoV-2 serum antibodies. 323

Finally, given that having multiple isotypes associate with higher neutralization, we were 324

interested in understanding the anti-RBD and N antibody signatures present in individuals and how 325

they correlated with neutralization. Therefore, we classified whether the presence or absence of 326

certain antigen-specific antibody isotypes (based on ELISA cutoffs) related to neutralization level. 327

The 101 COVID-19 patients comprised 21 different antibody combinations, or “clusters” (Fig. 328

5a), ranging from being positive for all six antibodies (N/RBD IgG, IgA, IgM) to three individuals 329

who did not have antibodies to neither N or RBD (Fig. 5a and b, Cluster U). We found that 4 out 330

of the 6 healthcare workers with high neutralizing titers (MIC = 1/640 – 1/2560) had sera that 331

tested positive for all three isotypes (IgA, IgG, and IgM) responsive against both Spike RBD and 332

N (Fig. 5b, Cluster A). However, two individuals with high neutralizing titers (#61 and 67) 333

contained a combination of isotypes that were shared with both medium and low neutralizers (Fig. 334

5b, Clusters C and D). Interestingly, Cluster B, which only lacks IgM against the RBD does not 335

have high neutralization compared with Clusters A, C, and D, suggesting that specific antibody 336

combinations and/or titers may be necessary for maximum neutralization. Finally, the majority of 337

individuals had at least IgG and IgA directed against the RBD accompanied by IgG to N (Fig. 5b). 338

Taken together, these results suggest that having IgG alone may not be enough for efficient 339

neutralization, while having multiple isotypes at high titers present in serum leads to more potent 340

SARS-CoV-2 neutralization. 341

342

343

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 16: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

16

Discussion 344

Understanding the antibody response and potential immunity to SARS-CoV-2 is critical 345

for global public health and the development of efficacious vaccines1,3,26. In this study, we 346

performed a comprehensive analysis of the SARS-CoV-2-specific antibody response in 101 347

convalescent healthcare workers serum samples. We determined the neutralization capacity of the 348

sera using both authentic virus and pseudotyped particles, quantified the titers of three antibody 349

isotypes (IgG, IgM, and IgA) to both the spike receptor-binding domain and the nucleoprotein, 350

and investigated the correlation of neutralization and antibody levels. We found, that the serum 351

SARS-CoV-2 neutralizing antibody capacity was low for the majority of recovered individuals. In 352

extreme cases, we detected no antibodies against SARS-CoV-2 Spike RBD or N in three 353

individuals. These observations are in line with previously published studies and may suggest that 354

those infected do not produce efficient neutralizing antibodies or neutralizing antibodies rapidly 355

wane by the time samples are collected16,27,28,29. Detailed longitudinal studies are beginning to 356

emerge, showing that serum antibody levels are relatively stable or decrease over time30-32. In-line 357

with our results these studies find a positive correlation between IgG titers and 358

neutralization31,32. Further characterization of neutralization at early and late timepoints is 359

necessary to correlate antibody titer stability to viral protection. However, it is essential to keep in 360

mind that, while neutralization titers can be quantified by reliable laboratory assays, we do not 361

know the overall protective capacity of antibodies against SARS-CoV-2 in patients. Thus, those 362

with low neutralizing capacities in the lab (MIC < 1/80) could be efficiently protected from SARS-363

CoV-2 reinfection. Detailed studies monitoring initial and possible reinfections along with the 364

antibody response are crucial to understand immunity to SARS-CoV-2. 365

366

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 17: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

17

To further understand the composition of convalescent sera, we quantified the amounts of IgG, 367

IgA, and IgM targeting the spike protein RBD and N. We found 21 different antibody 368

combinations that did not directly correlate with days post symptom onset, yet did associate with 369

antibody neutralization. Of these combinations, the majority of individuals fell into four distinct 370

clusters comprised of different antigen-specific isotypes. It remains to be elucidated how these 371

clusters are generated and why certain clusters elicit potent SARS-CoV-2 neutralization (Cluster 372

A) and others do not (Cluster B). Since we use a targeted approach focusing on only two antigens 373

and specific epitopes, it is possible that there are other anti-SARS-CoV-2 antibodies that bind viral 374

particles and impact neutralization33. 375

Interestingly, we found high quantities of IgM present in some individuals from 32 to 50 376

days post symptom onset. These findings are intriguing since IgM antibodies are usually 377

considered as a marker of a recent infection and their circulating titers are thought to decrease as 378

class switching occurs to IgG and IgA. This observation is of importance for determining the 379

relative time of infection. In this situation, looking at multiple isotypes including IgA as well as 380

multiple antigens may be beneficial in determining the relative infection timeline. Along these 381

lines, we also found that individuals having multiple antibodies isotypes to both RBD and N had 382

the best neutralization. Moreover, we found that individuals who had IgG in combination with 383

IgM and IgA against the RBD had the greatest neutralization capacity, suggesting that the 384

generation of combinations of antibody isotypes against the RBD may provide the best 385

neutralization. It has been shown that severity of disease can play an important role in the antibody 386

response and it may be that in these individuals, disease is a driver for multiple isotypes and 387

increased neutralization15,34. Thus, understanding how enhanced disease burden leads to the 388

generation of multiple neutralizing isotypes will be crucial for vaccine development. 389

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 18: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

18

These results, particularly the presence of individuals with low neutralizing antibodies are 390

interesting as each individual in our cohort has recovered from SARS-CoV-2 infection. This 391

observation suggests that either we missed the period of robust neutralizing antibody production 392

in certain individuals or other mechanisms, such as potent SARS-CoV-2 specific T-cell 393

responses35,36,37-41, provided effective viral clearance and immunity. Future studies coupling 394

assessment of antibody and T-cell responses with key clinical information (age, sex, severity of 395

symptoms) will be essential to fully understand this complex immune response. Moreover, these 396

results also highlight the need to study the SARS-CoV-2 genetics as the virus encodes multiple 397

undefined accessory proteins that could impact the immune response during infection. 398

Additionally, longitudinal studies are necessary to fully understand the complex immune response 399

to SARS-CoV-2 in the hopes to contain this virus and to prepare for the emergence of related 400

viruses. 401

402

Acknowledgements 403

We thank all the volunteers for participation in this study and the members of the NYU Vaccine 404

Center and NYU Langone Health for obtaining these samples. We thank Drs. Chi Yun and Adriana 405

Heguy for access to the Mantis instrument. We thank members of each lab for helpful comments 406

and discussion on the study and manuscript. 407

408

409

410

411

412

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 19: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

19

References 413 1 Vabret, N. et al. Immunology of COVID-19: Current State of the Science. Immunity 52, 414

910-941, doi:10.1016/j.immuni.2020.05.002 (2020). 415 2 Bar-Zeev, N. & Moss, W. J. Encouraging results from phase 1/2 COVID-19 vaccine 416

trials. Lancet, doi:10.1016/S0140-6736(20)31611-1 (2020). 417 3 Sempowski, G. D., Saunders, K. O., Acharya, P., Wiehe, K. J. & Haynes, B. F. Pandemic 418

Preparedness: Developing Vaccines and Therapeutic Antibodies For COVID-19. Cell 419 181, 1458-1463, doi:10.1016/j.cell.2020.05.041 (2020). 420

4 Stadlbauer, D. et al. SARS-CoV-2 Seroconversion in Humans: A Detailed Protocol for a 421 Serological Assay, Antigen Production, and Test Setup. Curr Protoc Microbiol 57, e100, 422 doi:10.1002/cpmc.100 (2020). 423

5 Biggs, H. M. et al. Estimated Community Seroprevalence of SARS-CoV-2 Antibodies - 424 Two Georgia Counties, April 28-May 3, 2020. MMWR Morb Mortal Wkly Rep 69, 965-425 970, doi:10.15585/mmwr.mm6929e2 (2020). 426

6 Luchsinger, L. L. et al. Serological Analysis of New York City COVID19 Convalescent 427 Plasma Donors. medRxiv, doi:10.1101/2020.06.08.20124792 (2020). 428

7 Krammer, F. & Simon, V. Serology assays to manage COVID-19. Science 368, 1060-429 1061, doi:10.1126/science.abc1227 (2020). 430

8 Havers, F. P. et al. Seroprevalence of Antibodies to SARS-CoV-2 in 10 Sites in the 431 United States, March 23-May 12, 2020. JAMA Intern Med, 432 doi:10.1001/jamainternmed.2020.4130 (2020). 433

9 Amanat, F. et al. A serological assay to detect SARS-CoV-2 seroconversion in humans. 434 Nat Med 26, 1033-1036, doi:10.1038/s41591-020-0913-5 (2020). 435

10 Premkumar, L. et al. The receptor binding domain of the viral spike protein is an 436 immunodominant and highly specific target of antibodies in SARS-CoV-2 patients. Sci 437 Immunol 5, doi:10.1126/sciimmunol.abc8413 (2020). 438

11 Seydoux, E. et al. Characterization of neutralizing antibodies from a SARS-CoV-2 439 infected individual. bioRxiv, doi:10.1101/2020.05.12.091298 (2020). 440

12 Jiang, H. W. et al. SARS-CoV-2 proteome microarray for global profiling of COVID-19 441 specific IgG and IgM responses. Nat Commun 11, 3581, doi:10.1038/s41467-020-17488-442 8 (2020). 443

13 Amanat, F. et al. A serological assay to detect SARS-CoV-2 seroconversion in humans. 444 medRxiv, doi:10.1101/2020.03.17.20037713 (2020). 445

14 Robbiani, D. F. et al. Convergent antibody responses to SARS-CoV-2 in convalescent 446 individuals. Nature, doi:10.1038/s41586-020-2456-9 (2020). 447

15 Wang, Y. et al. Kinetics of viral load and antibody response in relation to COVID-19 448 severity. J Clin Invest, doi:10.1172/JCI138759 (2020). 449

16 Liu, A. et al. Disappearance of antibodies to SARS-CoV-2 in a Covid-19 patient after 450 recovery. Clin Microbiol Infect, doi:10.1016/j.cmi.2020.07.009 (2020). 451

17 Barnes, C. O. et al. Structures of human antibodies bound to SARS-CoV-2 spike reveal 452 common epitopes and recurrent features of antibodies. bioRxiv, 453 doi:10.1101/2020.05.28.121533 (2020). 454

18 Dogan, M. et al. Novel SARS-CoV-2 specific antibody and neutralization assays reveal 455 wide range of humoral immune response during COVID-19. medRxiv, 456 doi:10.1101/2020.07.07.20148106 (2020). 457

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 20: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

20

19 Harcourt, J. et al. Isolation and characterization of SARS-CoV-2 from the first US 458 COVID-19 patient. bioRxiv, doi:10.1101/2020.03.02.972935 (2020). 459

20 Crawford, K. H. D. et al. Protocol and Reagents for Pseudotyping Lentiviral Particles 460 with SARS-CoV-2 Spike Protein for Neutralization Assays. Viruses 12, 461 doi:10.3390/v12050513 (2020). 462

21 Zost, S. J. et al. Potently neutralizing and protective human antibodies against SARS-463 CoV-2. Nature, doi:10.1038/s41586-020-2548-6 (2020). 464

22 Schmidt, F. et al. Measuring SARS-CoV-2 neutralizing antibody activity using 465 pseudotyped and chimeric viruses. J Exp Med 217, doi:10.1084/jem.20201181 (2020). 466

23 Leung, D. T. et al. Antibody response of patients with severe acute respiratory syndrome 467 (SARS) targets the viral nucleocapsid. J Infect Dis 190, 379-386, doi:10.1086/422040 468 (2004). 469

24 Shang, J. et al. Cell entry mechanisms of SARS-CoV-2. Proc Natl Acad Sci U S A 117, 470 11727-11734, doi:10.1073/pnas.2003138117 (2020). 471

25 Ravichandran, S. et al. Antibody signature induced by SARS-CoV-2 spike protein 472 immunogens in rabbits. Sci Transl Med 12, doi:10.1126/scitranslmed.abc3539 (2020). 473

26 Zohar, T. & Alter, G. Dissecting antibody-mediated protection against SARS-CoV-2. Nat 474 Rev Immunol 20, 392-394, doi:10.1038/s41577-020-0359-5 (2020). 475

27 Wu, L. P. et al. Duration of antibody responses after severe acute respiratory syndrome. 476 Emerg Infect Dis 13, 1562-1564, doi:10.3201/eid1310.070576 (2007). 477

28 Vabret, N. Antibody responses to SARS-CoV-2 short-lived. Nat Rev Immunol, 478 doi:10.1038/s41577-020-0405-3 (2020). 479

29 Robbiani, D. F. et al. Convergent Antibody Responses to SARS-CoV-2 Infection in 480 Convalescent Individuals. bioRxiv, doi:10.1101/2020.05.13.092619 (2020). 481

30 Wang, K. et al. Longitudinal dynamics of the neutralizing antibody response to SARS-482 CoV-2 infection. Clin Infect Dis, doi:10.1093/cid/ciaa1143 (2020). 483

31 Wajnberg, A. et al. SARS-CoV-2 infection induces robust, neutralizing antibody 484 responses that are stable for at least three months. medRxiv, 2020.2007.2014.20151126, 485 doi:10.1101/2020.07.14.20151126 (2020). 486

32 Suhandynata, R. T. et al. Commercial Serology Assays Predict Neutralization Activity 487 Against SARS-CoV-2. medRxiv, 2020.2007.2010.20150946, 488 doi:10.1101/2020.07.10.20150946 (2020). 489

33 Jiang, S., Hillyer, C. & Du, L. Neutralizing Antibodies against SARS-CoV-2 and Other 490 Human Coronaviruses: (Trends in Immunology 41, 355-359; 2020). Trends Immunol 41, 491 545, doi:10.1016/j.it.2020.04.008 (2020). 492

34 Phipps, W. S. et al. SARS-CoV-2 Antibody Responses Do Not Predict COVID-19 493 Disease Severity. Am J Clin Pathol, doi:10.1093/ajcp/aqaa123 (2020). 494

35 Elizaldi, S. R. et al. SARS-CoV-2 infection induces germinal center responses with 495 robust stimulation of CD4 T follicular helper cells in rhesus macaques. bioRxiv, 496 doi:10.1101/2020.07.07.191007 (2020). 497

36 Schultheiss, C. et al. Next-Generation Sequencing of T and B Cell Receptor Repertoires 498 from COVID-19 Patients Showed Signatures Associated with Severity of Disease. 499 Immunity, doi:10.1016/j.immuni.2020.06.024 (2020). 500

37 Peng, Y. et al. Broad and strong memory CD4 (+) and CD8 (+) T cells induced by 501 SARS-CoV-2 in UK convalescent COVID-19 patients. bioRxiv, 502 doi:10.1101/2020.06.05.134551 (2020). 503

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 21: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

21

38 Juno, J. A. et al. Humoral and circulating follicular helper T cell responses in recovered 504 patients with COVID-19. Nat Med, doi:10.1038/s41591-020-0995-0 (2020). 505

39 Grifoni, A. et al. Targets of T Cell Responses to SARS-CoV-2 Coronavirus in Humans 506 with COVID-19 Disease and Unexposed Individuals. Cell 181, 1489-1501 e1415, 507 doi:10.1016/j.cell.2020.05.015 (2020). 508

40 Channappanavar, R., Zhao, J. & Perlman, S. T cell-mediated immune response to 509 respiratory coronaviruses. Immunol Res 59, 118-128, doi:10.1007/s12026-014-8534-z 510 (2014). 511

41 Altmann, D. M. & Boyton, R. J. SARS-CoV-2 T cell immunity: Specificity, function, 512 durability, and role in protection. Sci Immunol 5, doi:10.1126/sciimmunol.abd6160 513 (2020). 514

515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 22: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

22

Extended Data Table 1: SARS-CoV-2 positive NYU healthcare worker information and data used in this study.

COVID-19

Patient #

Sympt. onset date

Days post

sympt. onset

Anti-N ELISA* Anti-RBD ELISA** Neutralization SARS-CoV-2

Neutralization Pseudotyped virus

IgG IgA IgM IgG IgA IgM 1/MIC 1/IC90 1/IC50

1 3/16/20 43 31.59 5.54 24.32 2.152 0.344 0.211 40 44.9 108 2 3/18/20 41 18.14 0.58 9.26 0.892 0.244 0.217 20 32.83 125 3 3/17/20 42 38.76 3.6 5.58 2.943 0.927 0.257 160 127.7 361 4 3/12/20 47 9.24 0.43 0.71 1.921 0.214 0.209 20 27.7 61 5 3/20/20 39 7.56 0.77 4.42 0.88 0.19 0.202 40 18.69 44 6 3/19/20 40 37.18 4.03 11.76 2.857 0.545 0.441 80 57.75 121 7 3/15/20 44 17.47 0.31 1.97 2.627 0.183 0.204 40 42.9 121 8 3/19/20 40 7.58 3.54 19.43 2.068 0.987 0.216 40 40.93 95 9 3/8/20 51 27.15 2.92 12.8 2.666 0.345 0.532 80 64.58 181 10 3/18/20 41 41.83 3.23 16.48 2.848 1.314 2.514 320 120.4 1094 11 3/17/20 42 24.15 1.14 10 1.783 0.338 0.466 40 16.5 59 12 3/11/20 48 37.95 5.78 1.52 2.281 0.507 0.437 80 22.88 94 13 3/9/20 50 41.84 45.02 35.09 2.993 3.364 3.296 2560 157.1 1919 14 3/17/20 42 24.4 0.74 4.53 2.301 0.555 0.31 80 12.31 77 15 3/16/20 43 23.79 1.11 6.15 2.452 0.583 1.811 160 40.52 107 16 3/19/20 40 7.29 3.29 6.7 2.068 1.041 0.553 40 18.01 97 17 3/28/20 41 15.5 17.09 12.11 1.008 0.178 0.616 40 50.47 163 18 3/13/20 46 29.12 4.8 33.01 1.532 0.379 0.829 160 58.97 170 19 3/24/20 35 5.98 0.95 4.73 1.091 0.204 0.328 40 20.99 91 20 3/20/20 39 17.41 5.26 25.58 2.788 0.501 0.773 160 86.11 282 21 3/18/20 41 5.09 1.08 1.66 1.388 0.233 0.295 40 17.51 63 22 3/20/20 39 37.97 95.17 19.05 3.064 2.564 1.312 640 187.3 4752 23 3/4/20 55 37.55 11.99 25.16 2.708 0.414 0.285 80 88.19 299 24 3/2/20 57 12.97 0.52 19.24 2.068 0.328 0.482 80 33.73 305 25 3/6/20 53 34.37 0.52 5.2 1.846 0.307 0.44 40 26.55 116 26 3/23/20 36 13.11 1.51 1.09 2.114 0.275 0.222 20 10.23 92 27 3/20/20 39 7.6 0.34 9.31 1.712 0.338 0.351 20 13.78 52 28 3/24/20 35 17.53 1.08 5.92 1.884 0.707 0.399 40 26.87 91 29 3/25/20 34 32.97 2.34 16.96 2.764 2.091 3.035 160 77.9 195 30 3/22/20 37 32.52 5.29 3.18 2.772 1.522 0.74 80 62.62 221 31 3/20/20 39 6.22 4.4 3.64 1.471 0.532 0.335 20 13.31 65 32 3/20/20 39 26.69 4.03 15.65 2.457 3.034 0.956 160 37.89 131 33 3/20/20 39 21.03 1.2 3.09 1.752 0.209 0.455 40 63.95 182 34 3/21/20 38 50.25 9.56 39.24 2.848 3.452 2.398 640 175.9 1509 35 3/23/20 36 22.76 1.2 6.1 1.469 0.584 0.896 160 38.32 117 36 3/16/20 43 4.01 0.86 3.96 1.528 0.37 0.519 40 49.28 145 37 3/15/20 44 6.89 0.86 10.95 0.898 0.594 0.472 Neg 7.66 34 38 3/19/20 40 16.11 0.49 11.15 2.11 0.303 0.177 40 40.05 150 39 3/21/20 38 29.52 2.77 5.28 2.602 1.752 0.796 80 73.12 272 40 3/19/20 40 6.5 1.26 2.85 1.203 0.228 0.443 20 3.33 36 41 3/15/20 44 34.99 0.65 4.28 1.76 0.313 0.582 40 20.6 92 42 3/16/20 43 5.59 0.58 11.97 1.804 0.274 0.602 40 42.1 248 43 3/24/20 35 32.38 4.74 18.91 2.019 0.48 0.706 80 42.33 152 44 3/14/20 45 32.36 1.14 8.27 1.829 0.761 0.413 20 25.9 88 45 3/19/20 40 40.06 0.74 1.43 1.624 0.255 0.382 80 25.36 121 46 3/16/20 43 15.22 1.26 17.94 1.778 0.35 0.834 80 30.3 122 47 3/20/20 39 27.9 3.38 13.16 1.664 0.404 0.713 40 3.04 60 48 3/20/20 39 24.34 0.68 6.93 1.468 0.289 1.293 160 38.18 345 49 3/19/20 40 19.7 6.86 1.74 1.965 0.53 0.278 40 35.9 148 50 3/27/20 32 15.54 1.08 2.38 2.191 0.487 0.113 80 30.31 137 51 3/23/20 36 24.6 1.6 10.88 2.221 0.223 0.272 80 18.7 83

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 23: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

23

52 3/27/20 32 36.07 4.15 20.35 2.896 1.079 0.484 80 41.24 235 53 3/15/20 44 41.3 3.81 3.39 2.701 0.723 1.381 320 77.67 1101 54 3/20/20 39 56.66 1.97 5.68 2.703 0.317 0.844 320 55.85 765 55 3/19/20 40 13.23 0.74 9.83 1.094 0.139 0.479 40 0.776 10 56 3/19/20 40 11.12 1.48 7.88 1.977 0.215 1.641 40 15.02 53 57 3/18/20 41 12.85 5.14 11.17 0.977 0.287 0.582 20 13.61 38 58 3/26/20 33 41.54 4.27 13.32 2.754 0.363 0.927 160 77.31 243 59 3/19/20 40 46.08 4.55 7.03 2.985 0.436 0.781 80 21.98 524 60 3/14/20 45 18.7 4.74 31.09 1.714 0.411 0.399 40 11.49 48 61 3/20/20 39 27.36 4.89 10.22 2.872 2.197 2.89 640 321.3 785 62 3/23/20 36 31.91 0.92 5.15 3.227 0.974 1.667 160 98.68 1729 63 3/18/20 41 39.41 15.62 13.18 1.967 0.308 0.421 40 1.105 27 64 3/15/20 44 15.48 0.86 2.49 1.874 0.248 1.104 40 54.83 253 65 3/22/20 37 6.26 1.41 15.27 0.598 0.282 0.344 20 9.62 36 66 3/20/20 39 26.32 1.91 17.7 2.08 0.324 0.64 160 60.52 239 67 3/9/20 50 42.07 2.89 6.98 2.971 0.706 1.04 640 227.7 577 68 3/6/20 53 12.03 0.52 1.5 1.261 0.301 0.372 40 16.19 88 69 3/26/20 33 15.64 10.42 2.97 1.818 0.516 0.369 40 21.06 56 70 3/21/20 38 33.25 2.86 5.03 3.209 1.252 1.078 320 118.5 420 71 3/26/20 33 22.59 0.71 11.9 2.768 0.768 0.45 40 27.79 94 72 3/23/20 36 25.07 1.91 6.49 2.906 0.329 1.275 160 54.04 149 73 3/19/20 40 21.05 0.55 1.55 1.84 0.181 0.388 40 72.73 178 74 3/21/20 38 12.26 0.98 6.55 0.525 0.175 0.514 20 26.93 88 75 3/24/20 35 6.79 0.62 2.02 1.73 0.121 0.272 20 15.35 52 76 3/23/20 36 40.43 2.95 16.96 nd nd nd 80 90.81 324 77 3/16/20 43 22.11 0.4 4.51 2.205 0.364 0.907 40 50.05 158 78 3/22/20 37 51.14 7.93 52.71 3.197 1.149 1.417 320 86.66 716 79 3/26/20 33 11.02 0.31 4.09 0.829 0.171 0.771 40 12.67 60 80 3/20/20 39 20.06 0.31 3.56 2.665 0.421 0.801 40 50.24 171 81 3/22/20 37 2.43 2.37 2.71 0.76 0.121 0.399 Neg 7.09 35 82 3/24/20 35 19.35 1.11 21.83 0.603 0.257 0.659 20 neg neg 83 3/26/20 33 37.87 8.49 52.71 3.265 3.204 1.204 320 152.8 2819 84 3/26/20 33 41.3 35.55 52.71 3.184 2.454 2.725 1280 195.1 538 85 3/19/20 40 10.9 2.12 3.26 1.819 0.177 0.191 20 51.81 132 86 3/24/20 38 10.92 1.01 6.65 nd nd nd 20 9.92 49 87 3/17/20 45 7.98 2.31 5.82 1.571 0.176 0.923 20 26.96 83 88 3/8/20 54 38.89 3.91 23.07 2.794 0.391 1.079 80 63.96 250 89 3/26/20 36 53.11 15.04 5.13 3.066 1.041 0.639 320 115.4 465 90 3/22/20 40 30.4 3.47 7.82 3.019 0.205 0.461 80 96.81 311 91 3/15/20 47 12.26 0.55 1.78 0.82 0.094 0.326 20 4.66 36 92 3/27/20 35 19.63 0.72 2.41 2.257 0.488 0.305 40 42.43 135 93 3/17/20 45 29.03 0.74 2.17 2.861 0.671 0.735 80 92.69 270 94 3/28/20 34 15.73 3.75 4.75 2.471 0.384 0.454 80 85.51 218 95 3/20/20 42 31.75 2.45 5.49 2.493 0.296 0.532 40 31.98 125 96 3/20/20 42 28.53 2.27 11.82 2.777 0.899 0.729 80 47.39 176 97 3/25/20 37 33.44 31.98 4.32 2.419 0.351 0.536 80 47.98 170 98 3/19/20 43 20.89 1.54 8.85 1.913 0.602 0.612 40 12.62 55 99 3/13/20 49 36.93 4.47 8.72 2.463 1.887 0.583 160 54.63 299 100 3/28/20 34 18.94 6.92 6.99 1.122 0.347 0.339 40 21 111 101 3/27/20 35 4.99 1.54 2.33 0.796 0.147 0.261 20 23.55 68

*Threshold for Anti-NP ELISA (IgG, IgM, IgA OD450 < 9). **Threshold for Anti-RBD ELISA (-IgG is OD490nm = 1.091; -IgM is OD490nm = 0.256 and -IgA is OD490nm = 0.694). nd. measures not included in the analysis.

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 24: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

SARS-CoV-2 (PCR-positive) healthcare workers

(N = 101)

Sera collection(32-57 days post symptom onset)

IgG IgM IgA

SARS-CoV-2authentic virus neutralization

SARS-CoV-2pseudotyped virus neutralization

Nucleoprotein (N)

Spike - Receptor binding domain (RBD)

Neutralizationassays

ELISA assays

a.

Pse

udot

yped

viru

s (L

og 2 1/IC

90)

SARS-CoV-2 virus (Log2 1/MIC)

114 5 6 7 8 9 10

-4-202468

10

R2 =0.4863P < 0.0001

b.

32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56

20

2560

40

(1/M

IC)

Neu

traliz

atio

n

80160320640

1280

Low

Interm.

High

Neutralization categories

Days post symptom onset

non-neutralizing sera

c.

1/MIC

1/IC 90

CO

VID

-19

patie

nts

(%)

0255075

10074 % 79 %

23 %

1/IC 50

P = 0.5

P = 6.3 x 10-13

P = 1 x 10-15

1/MIC

1/IC 90

21 %20 %

73 %

1/IC 50

P = 1

P = 5.3 x 10-14

P = 1.8 x 10-13

Neutralization categories

1/MIC

1/IC 90

Low (dil: 1/10 to 1/80)

Intermediate(dil: 1/81 to 1/639)

High(dil > 1/640)

6 % 4 %

1/IC 50

P = 0.02

P = 0.74P = 0.12

0255075

100

0255075

100

SARS-CoV-2 Pseudotyped virus

57

12

e.

0 25 50 75 100

Rank (1/MIC - 1/IC90)

0

400

800

1200

1600

2000

2400

Neu

traliz

atio

n tit

er (1

/dilu

tion) SARS-CoV-2 (1/MIC)

Pseudotyped virus (1/IC90)

Intermediate

High

d.

Figure 1. SARS-CoV-2 neutralizing antibody response. a. Schematic representation of the experimental design. b. Correlation analysis of the sera neutralization level of 101 COVID-19 convalescent patients. The data presented are the log2 of the neutralization titer against the authentic SARS-CoV-2 virus (1/MIC) and the pseudo-typed virus (1/IC90). Correlation and linear regression analyses were performed using GraphPad Prism 8. P values were calculated using a two-sided F-test. c. SARS-CoV-2 neutralization categories. Sera of convalescent patients was defined as low (dil:1/10 to 1/80), intermediate (dil:1/81 to 1/639) and high (dil > 1/640) based on authentic SARS-CoV-2 virus (blue box) or pseudotyped virus (red box). P values were calculated using two-sided Fisher’s exact test. d. Rank of the absolute differences in neutralization capacity from sera of 101 COVID-19 convalescent patients. Neutralization titers against SARS-CoV-2 virus (blue) or pseudotyped virus (red) was ordered based on the absolute difference between 1/MIC and 1/IC90. Dashed lines indicate the different neutral-ization categories. The gray box highlights those samples with the highest absolute difference in the neutralization capacity between SARS-CoV-2 virus (blue) or pseudotyped virus (red). e. Distribution of authentic SARS-CoV-2 virus neutralization titers (1/MIC) over days post symptom onset. Dashed lines indicate the neutralization levels as defined in panel B. White dots indicate two individuals with SARS-CoV-2 non-neutralizing sera.

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 25: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

1

0

2

3

4

0 10 20 30 40 50 60

a.

c.

b.

R2 = 0.2327

0 20 40 60 80 100

1

0

2

3

4

R2 = 0.20651

0

2

3

4

0 10 20 30 40 50 60

anti-

RBD

IgA

(OD 49

0nm)

anti-N IgA (OD 450nm)

IgG N

0

25

50

75

100

IgG R

BD

CO

VID

-19

patie

nts

(%)

P = 0.54IgG positiveIgG negative

IgM N

0

25

50

75

100

IgM R

BD

CO

VID

-19

patie

nts

(%)

P = 0.56IgM positiveIgM negative

IgA N

0

25

50

75

100

IgA R

BD

CO

VID

-19

patie

nts

(%)

P = 2 x 10-16

IgA positiveIgA negative

R2 = 0.5087 P = 2.3 x 10-15

P = 1.15 x 10-5

P = 1.26 x 10-6

anti-

RBD

IgM

(OD 49

0nm)

anti-N IgM (OD450nm)

anti-

RBD

IgG

(OD 49

0nm)

anti-N IgG (OD 450nm)

Figure 2. Isotype composition of SARS-CoV2 convalescent serum. Anti-RBD and anti-N ELISA correlation for IgG (a), IgM (b) and IgA (c). Left panels: Correlations and linear regres-sions comparing anti-RBD and anti-N for each antibody isotype (N=101). Analyses were performed using GraphPad Prism 8. P values were calculated using a two-sided F-test. The red dashed lines indicate the threshold (anti-N ELISA for -IgG, -IgM or -IgA are OD450nm = 9; anti-RBD ELISA for -IgG is OD490nm = 1.091; -IgM is OD490nm = 0.256 and -IgA is OD490nm = 0.694) for each ELISA. Right panels indicate the percentage of COVID-19 PCR-positive patients that are positive (blue bars) or negative (gray bars) for IgG (a), IgM (b) or IgA (c). P values were calculated using two-sided Fisher’s exact test.

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 26: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

4 6 8 10 12

Neutralization Log2 (1/MIC)

Pseudotyped virus

R2 = 0.4786

0

1

2

3

4

-1

0

1

2

3

4

-1

0

1

2

3

4R2 = 0.5194

R2 = 0.5101

SARS-CoV-2

R2 = 0.4561

R2 = 0.2556

R2 = 0.2391

0 2 4 6 8 100

anti-

RBD

IgG

(OD

490n

m)

a. b.

Neutralization Log2 (1/IC90)

0

1

2

3

4

-1

0

1

2

3

4

-1

0

1

2

3

4

anti-

RBD

IgA

(OD

490n

m)

anti-

RBD

IgM

(OD

490n

m)

Figure 3. Correlation of anti-RBD antibody isotypes with viral neutralization. Anti-RBD ELISA correlation for IgG (top), IgA (Middle) and IgM (Bottom) with viral neutralization using authentic SARS-CoV-2 (a) or Pseudotyped virus (b). Correlation and linear regression analyses were performed using GraphPad Prism 8. P values were calculated using a two-sided F-test. The red dashed lines indicate the threshold (anti-RBD ELISA for -IgG is OD490nm = 1.091; -IgM is OD490nm = 0.256 and -IgA is OD490nm = 0.694) for each ELISA.

P< 0.0001

P< 0.0001

P< 0.0001

P< 0.0001

P< 0.0001

P< 0.0001

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 27: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

anti-RBD ELISA

IgG IgM IgA

(1/MIC)Neutralization anti-N ELISA

a. b.

IgG IgM IgA

1 2 3OD490nm 10 30 50 70 90

OD450nm

SARS-CoV-2

2560

640

320

160

804020<20

1280

Low Interm. High

Neutralization Level

2560

640

320

160

804020<20

1280

Low Interm. High

Neutralization Level

(1/MIC)Neutralization

SARS-CoV-2

CO

VID

-19

Pat

ient

CO

VID

-19

Pat

ient

c.

d.

0.5

1.0

1.5

2.0

2.5

3.0

3.5

1.0 1.5 2.0 2.5 3.0 3.5

R2 = 0.1957

R2 = 0.1406 R2 = 0.0831 R2 = 0.106

1.0 1.5 2.0 2.5 3.0 3.5

0

0.5

1.0

1.5

2.0

2.5

3.0

3.5R2 = 0.2794

0.5 1.0 1.5 2.0 2.5 3.0 3.5

0.5

1.0

1.5

2.0

2.5

3.0

3.5R2 = 0.4424

510152025303540455055

10 20 30 40 50 60

10

20

30

40

50

60

70

80

90

100

10 20 30 40 50

anti-

RBD

IgM

(OD 49

0nm

)

anti-RBD IgG (OD490nm)

anti-

RBD

IgA

(OD 49

0nm

)

anti-RBD IgG (OD490nm)

anti-

RBD

IgA

(OD 49

0nm

)

anti-RBD IgM (OD490nm)

MIC

Level

HighIntermediateLow

anti-N IgG (OD450nm)

anti-

N Ig

M (O

D45

0nm

)

ant

i-N Ig

A (O

D45

0nm

)

0

10

20

30

40

50

60

70

80

90

100

0 10 20 30 40 50 60anti-N IgG (OD450nm) anti-N IgM (OD450nm)

anti-

N Ig

A (O

D45

0nm

)

P = 2.71 x 10-6 P = 1.12 x 10-8 P = 3.59 x 10-14

P = 7.77 x 10-5 P = 0.0016 P = 0.0006

1/2560

1/20

MIC

Level

HighIntermediateLow

1/2560

1/20

Figure 4. Identification of serological signatures for neutralization. Heatmap of anti-RBD (a) and anti-N (b) antibody isotype ELISA titers and corresponding authentic SARS-CoV-2 neutralization. Serological data from the 101 COVID-19 patients was ranked from low to high neutralization. Sera of convalescent patients was defined as low (dil:1/10 to 1/80), intermediate (dil:1/81 to 1/639) and high (dil > 1/640). Red bar indicates those COVID-19 patients with high neutralizer antibodies. c. Correlation analysis of anti-RBD IgM vs IgG (left panel), anti-RBD IgA vs IgG (middle panel) and anti-RBD IgA vs IgM (right panel). d. Correlation analysis of anti-N IgM vs IgG (left panel), anti-N IgA vs IgG (middle panel) and anti-N IgA vs IgM (right panel). For (c) and (d) correlation and linear regression analyses were performed using the linear model function in R (lm). P values were calculated using a two-sided F-test. The size of the dots indicates the MIC and the color of the dots indicates the neutralization category: High (red dots), Intermediate (blue) and Low (gray) as determined using authentic SARS-CoV-2 neutralization (see Fig. 2 legend).

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 28: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

16

64

256

1024

4096

16

64

256

1024

4096

Neu

traliz

atio

n (1

/MIC

)

178 422757 826556 6451 55 74 9121192877937 75407345 908574 333116 36

2625 4128123 14 95 989468 10099924944 502411 523861 9 71604839 54533015 35 6259 7270 807767 9386

2234 8413

5 81 101

8969 97

Low (MIC 1/20 - 1/80) Medium (MIC 1/160 - 1/320) High (MIC 1/640 - 1/2560)

10 18 20 29 32 43 46 47 58 61 66 76 78 83 88 96

<1/20<1/20

anti-RBD

anti-N

IgG

IgM

IgA

IgG

IgM

IgA

24 1616 39 217 32 13 73 11 4 31 32# of COVID-19 patients in each cluster

a. b.

16

64

256

1024

4096

A B C D E F G H I J K L M N O P Q R S T U

Cluster Class

H L M

6423COVID-19 patient #

A

RBD

N

B C

D E F G

I J K

Neu

traliz

atio

n (1

/MIC

)N

eutra

lizat

ion

(1/M

IC) N O P Q R S UT

COVID-19 patient #

COVID-19 patient #IgGIgMIgA

Figure 5. Clustering analysis of individual SARS-CoV-2 antibody response. a. Combination of antibody isotypes in individual patient sera defining different cluster classes. ELISA titers were categorized as positive (ELISA titers > cutoff) or negative (ELISA titer < cutoff) for each sample for each individual antibody isotype. Clusters were made based on the presence or absence of specific isotypes (Cluster A to U). The number of patients in each cluster is shown on the x axis. b. Neutralization levels shown for each individual antibody cluster.

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 29: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

a.

670

158

44 17 1.35

0 5 10 15 20 25

0

5

10250

150

10075

50

37

252015

10

M 1

A28

0nm

(mA

U)

Elution Volume (ml)

Isotype Serum dilution Sensitivity Specificity

IgG 158 0.881 0.976

IgG 500 0.901 0.976

IgM 158 0.386 0.976

IgM 500 0.386 1.000

IgA 158 0.762 1.000

IgA 500 0.752 1.000

Positive Negative Positive Negative

0

1

2

3

4

OD

(490

nm

)

IgG (x158)

IgM (x158)

IgA (x158)

IgG (x500)

IgM (x500)

IgA (x500)

0

1

2

3

4

OD

(490

nm

)

0

1

2

3

4

OD

(490

nm

)

c.

d.

b.

3 S

D3

SD

3 S

D

cutoff: 1.091

cutoff: 0.694

cutoff: 0.256

cutoff: 0.568

cutoff: 0.295

cutoff: 0.174

Extended Data Figure. 1. Production of SARS-CoV-2 Spike RBD antigen and characterization of anti-RBD ELISA. a. SDS-PAGE of purified RBD-His6-Avi-biotin using the Bio-Rad stain-free detection method. Lane M contains standards with its molecular weight in kDa. b. Purified RBD-His6-Avi-biotin size-exclusion chromatography on a Superdex 75 10/300 Increase column detected using absorbance at 280 nm. The elution positions of molecular weight standards are marked as bars with their molecular weights in kDa. c. Determina-tion of ELISA thresholds. Serum from the 101 SARS-CoV-2 PCR positive were diluted 1/158 and 1/500 and compared with 43 SARS-CoV-2 PCR negative individuals. The cutoff values were defined as the mean plus three times the standard deviation (SD) of the negative control samples as shown by the red arrow. The dashed line indicates the position of each individual cutoff. Cutoff values are indicated in red. d. Table showing the sensitivity (% of true positive in positive) and specificity (% of true negative in negative) of each RBD antibody subtype and dilution.

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 30: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

0

20

40

60

80

100

120

020

40

6080

100120140

0

20

40

60

80

100

120

0

20

40

60

80

100

120

0

20

40

60

80

100

120

% C

ontro

l

1 2 31 2 3 1 2 3 1 2 3Log10 Serum Dilution Log10 Serum Dilution Log10 Serum Dilution Log10 Serum Dilution

12345

678910

1112131415

1617181920

2122232425

2627282930

3132333435

3637383940

4142434445

4647484950

5152535455

5657585960

6162636465

6667686970

7172737475

7677787980

8182838485

8687888990

9192939495

96979899100101

0

20

40

60

80

100

120

0

20

40

60

80

100

120

0

20

40

60

80

100

120

020

40

60

80

100

120

0

20

40

60

80

100

120

0

20

40

60

80

100

120

0

20

40

60

80

100

120

0

20

40

60

80

100

120

0

20

40

60

80

100

120

020

406080

100

120140

0

20

40

60

80

100

120

0

20

40

60

80

100120

0

20

40

60

80

100

120

020

40

60

80

100

120

020

406080

100

120140

1 2 3 1 2 3 4 1 2 3 4 1 2 3

1 2 3 4 1 2 3 4 1 2 3 4

1 2 3 4 1 2 3 4 1 2 3 4

1 2 3 4

1 2 3

1 2 3

1 2 3 1 2 3 1 2 3 4

% C

ontro

l%

Con

trol

% C

ontro

l%

Con

trol

Extended Data Figure 2. Individual sera neutralization of pseudotyped virus. Pseudotyped virus was mixed 1:1 with 2-fold dilutions of individual sera and incubated at room temperature for 30 minutes before infecting ACE2-293T cells. Relative infection was determined by luciferase expression 48 hrs post-incubation. Data is represented as the percentage of the untreated control. Data was fitted to a variable slope model log(serum dilution) versus response using Graph Pad prism.

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 31: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

00102030405060

R2 = 0.0027

1

0

2

3

4R2 = 8.859e-5

ant

i-RBD

IgG

(OD

490n

m)

ant

i-RBD

IgA

(OD

490n

m)

anti-

N Ig

G (O

D45

0nm)

Days post symptom onset30 40 50 60

a.

��

��

��

� �

��

� �

1020304050

Q1Days post symptom onset

(quartile)

Q2 Q3 Q4

P = 0.7P = 0.59

P = 0.5830 40 50 60

� �

��

��

��

�1.0

1.5

2.0

2.5

3.0

Quartile1 (32 to 37 days)

2 (38 to 40 days)

3 (41 to 43 days)

4 (44 to 57 days)

Q1 Q2 Q3 Q4

P = 0.75P = 0.44

P = 0.71 b.

102030405060 R2 = 0.0002

Days post symptom onset30 40 50 60

1

0

2

3

4 R2 = 0.0021

ant

i-RBD

IgM

(OD

490n

m)

30 40 50 60

ant

i-N Ig

M (O

D45

0nm)

c.

��

��

��

��

��

��

��

�� �

��

� �

�01020304050

Q1Days post symptom onset

(quartile)

Q2 Q3 Q4

P = 0.9P = 0.56

P = 0.69

��

��

��

1.01.52.02.53.0

Q1 Q2 Q3 Q4

P = 0.71P = 0.83

P = 0.84

1

0

2

3

4R2 = 0.0122

30 40 50 60

0

20

40

6080

100R2 = 0.0004

30 40 50 60

anti-

N Ig

A (O

D45

0nm)

25

50

75

��

� ��

��

��

��

��

��

��

1

2

3

Days post symptom onset Days post symptom onset (quartile)

Q1 Q2 Q3 Q4

P = 0.5P = 0.36

P = 0.20Q1 Q2 Q3 Q4

P = 0.7P = 0.49

P = 0.57

Extended Data Figure 3. Correlations between isotype composition of SARS-CoV-2 convalescent serum and days post onset of symptoms. Correlations of anti-RBD (top) or anti-N (bottom) IgG (a), IgM (b) and IgA (c) over days post onset of symptoms are shown. Quartiles were defined based on positive samples (data points > cutoff) for anti-RBD IgG. Each quartile has the following number of observations: anti-RBD IgG (n= 29, 30, 18, 22), anti-N IgG (n= 11, 13, 5, 8), anti-RBD IgM (n= 23, 20, 15, 17), anti-N IgM (n= 11, 12, 10, 8), anti-RBD IgA (n= 24, 28, 15, 20), anti-N IgA (n= 4, 2, 2, 2). P values were calculated using the Wilcoxon rank sum test. The red dashed lines indicate the threshold (anti-N ELISA for -IgG, -IgM or -IgA are OD450nm = 9; anti-RBD ELISA for -IgG is OD490nm = 1.091; -IgM is OD490nm = 0.256 and -IgA is OD490nm = 0.694) for each ELISA.

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint

Page 32: High titers of multiple antibody isotypes against the SARS-CoV-2 … · 2020. 8. 15. · 65 patient’s serum in terms of antigens, antibody isotypes (IgG, IgM, and IgA), and neutralization,

4 6 8 10 120

20

40

60

0

20

-20

40

60

-20

0 0

20

40

60

80

100

-20

0

20

40

60

4 6 8 10 12

4 6 8 10 12

R2 = 0.5277 R2 = 0.2615

R2 = 0.0808

R2 = 0.1033

R2 = 0.2437

R2 = 0.2141

-20

20

40

60

80

100

642 8 10 12

642 8 10 12

Pseudotyped virusSARS-CoV-2a. b.

Neutralization Log2 (1/MIC) Neutralization Log2 (1/IC90)

anti-

N Ig

G (O

D45

0nm

)an

ti-N

IgA

(OD

450n

m)

anti-

N Ig

M (O

D49

0nm

)

Extended Data Figure 4. Correlation of anti-N antibody isotypes with viral neutralization. Anti-N ELISA correlation for IgG (top), IgA (Middle) and IgM (Bottom) with viral neutralization using authentic SARS-CoV-2 (a) or Pseudotyped virus (b). Correlation and linear regression analyses were performed using GraphPad Prism 8. P values were calculated using a two-sided F-test. The red dashed lines indicate the threshold (anti-RBD ELISA for -IgG; -IgM and -IgA is OD450nm > 9) for each ELISA.

P< 0.0001

P< 0.0001

P< 0.0001P= 0.0011

P< 0.0001

P= 0.0041

0 2 4 6 8 10

-20

0

20

40

60

(which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. The copyright holder for this preprintthis version posted August 16, 2020. ; https://doi.org/10.1101/2020.08.15.252353doi: bioRxiv preprint