High Throughput Automation for EPAMethod 200.7 & 200.8
Stephen J. Mangum Elemental Scientific
NEMC Conference 2021
![Page 2: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/2.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
• SampleSense Enviro• Reduces EPA methods sample to sample time• Provides Quality Assurance for sample loading• Eliminates method timing• Eliminates loading variability due to sample viscosity
Improves Sample throughput without data compromise
New Automation Creating High Throughput
![Page 3: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/3.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
SampleSense Enviro
• What is SampleSense Enviro?
• DXCi Intelligent Autosampler
• SampleSense FAST• Vacuum control valve
• Pergo Argon Humidifier
![Page 4: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/4.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
DXCi: The Intelligent Autocorrecting Autosampler
![Page 5: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/5.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
• Monitors autosampler probe position in 3 axes of motion
• Intelligently corrects the position
• Reports unmoved obstructions
• Eliminates analytical interruptions
• Available in 2DXCi, 4DXCi, 8DXCi, 14DXCi
• All SampleSense systems will include new DXCi
New DXCi Intelligent Position‐Correcting Autosampler
![Page 6: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/6.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
• Optical sensors monitor for arrival of solution front at both entrance and exit.
• Solution arrival at both locations provides confirmation that sample loop is fully loaded
• Air bubbles during the sample loop loading are detected
SampleSense Valve – how does it work?
Exit Sample In
Sensors
SensorIndicators
![Page 7: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/7.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
SampleSense Enviro: Optimized QC Workflow
• Intelligent Sample Loading Verification• SampleSense Enviro reports non‐sample events:
• Capped Sample Vials• Underfilled Sample Vials• Underfilled/Empty QC Standards
• Log of “Un‐Sensed” Samples is Generated
![Page 8: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/8.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
SampleSense Enviro: Low Sample Consumption
• Vacuum‐Control Valve:• Trapping valve minimizes sample consumption. • Automatically shutting off the vacuum to conserve valuable sample.
• SampleSense Enviro consumes < 2.5 mL of sample*.• The black line shows the original level of 6 mL sample • Post analysis, 3.5 mL of sample remains for a potential reanalysis.
* System using 1.5 mL loop size
![Page 9: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/9.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
SampleSense Enviro Flow Diagram
![Page 11: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/11.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
Step 2:
When both sensors are triggered, vacuum valve closes and then sample valve switches to inject.
![Page 13: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/13.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
SampleSense Enviro Analytical Cycle
![Page 14: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/14.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
Experimental: Instrument Setup & Method conditions
Method settings use standard analytical conditions(Analytes, replicates, sample flow, etc.)
Method uses 3 replicates Uses < 2.5 mL sample/injection Probe washout and loop rinse are part of FAST method
![Page 15: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/15.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
Example ICP‐OES Time Savings (U.S. EPA Method 200.7)
Standard Valving System• 1:16 per sample
Sample Id Acquisition Time
Blank 8/22/2018 12:16:46 PMCal-1 8/22/2018 12:20:32 PMCal-2 8/22/2018 12:24:18 PMCal-3 8/22/2018 12:28:06 PMCal-4 8/22/2018 12:31:18 PMCal-5 8/22/2018 12:34:31 PM
Sample Id Acquisition Time
BLANK 8/22/2018 5:27:48 PMCal-1 8/22/2018 5:29:45 PMCal-2 8/22/2018 5:31:40 PMCal-3 8/22/2018 5:33:00 PMCal-4 8/22/2018 5:34:16 PMCal-5 8/22/2018 5:35:32 PM
Standard autosampler• 3:12 per sample
SampleSense Enviro System• 0:45 per sample
![Page 16: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/16.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
A Few Examples of Calibrations
![Page 17: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/17.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
Pergo ‐ Argon Humidifier
Benefits• Dissolves salt crystals at nebulizer tip
• Reduces long term drift• Improves stability• Improves detection limits
![Page 18: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/18.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
Experimental: Calibration and Data
0.0%
20.0%
40.0%
60.0%
80.0%
100.0%
120.0%
140.0%
160.0%
180.0%
200.0%
1 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55
% Recov
ery
Row Index Number
Y‐Axial
Sc‐Radial
Sc‐Axial
• Calibration for As 193
• IS plot over sample run
0.999997
![Page 19: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/19.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
Internal Standard Recovery
60%
80%
100%
120%
0:00 0:28 0:57 1:26 1:55 2:24 2:52 3:21 3:50 4:19 4:48
IS Recov
ery
Time (hours)
Drift without pergo
Sc 45 (IS)(cps)
Ge 72 (IS)(cps)
In 115 (IS)(cps)
Ir 193 (IS)(cps)
Rh 103(cps)
Tb 159(cps)
![Page 20: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/20.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
Internal Standard Recovery
60%
80%
100%
120%
0:00 0:28 0:57 1:26 1:55 2:24 2:52 3:21 3:50 4:19 4:48
IS Recov
ery
Time (hours)
Stable Signal with pergo
Sc 45 (IS)(cps)
Ge 72 (IS)(cps)
In 115 (IS)(cps)
Ir 193 (IS)(cps)
Rh 103(cps)
Tb 159(cps)
![Page 22: High Throughput Automation for EPA Method 200.7 & 200](https://reader031.vdocuments.us/reader031/viewer/2022020620/61e2d3fee8d5807b754092a0/html5/thumbnails/22.jpg)
© Elemental Scientific | www.icpms.com | [email protected]
Elemental Scientific
Questions??
SampleSense Enviro – provides fastest, most economical, most intelligent analysis