high performance centrifugal blowers · airfan is at the origin and owns many patents coming from...
TRANSCRIPT
![Page 1: HIGH PERFORMANCE CENTRIFUGAL BLOWERS · AIRFAN is at the origin and owns many patents coming from its R&D Center which guarantee its customers the best performance available on the](https://reader035.vdocuments.us/reader035/viewer/2022062510/61221974608db5393774c9ca/html5/thumbnails/1.jpg)
HIGH PERFORMANCE
FOR
CENTRIFUGAL BLOWERS
RESPIRATORY DEVICES
www.airfan.fr
the breath of performance
![Page 2: HIGH PERFORMANCE CENTRIFUGAL BLOWERS · AIRFAN is at the origin and owns many patents coming from its R&D Center which guarantee its customers the best performance available on the](https://reader035.vdocuments.us/reader035/viewer/2022062510/61221974608db5393774c9ca/html5/thumbnails/2.jpg)
Blower reference Application
O2 Before the
turbine
DP max (hPa)
at 24VDC*
Q (L/mn) Max]
at 24VDC*
DP max (hPa)
at Max Speed*
Q (L/mn) Max
at Max Speed*
WIT
H H
OU
SIN
G
MFA0500 Intensive, Critical and Home Care + O2 Port
110 380 119 (25V) 400 (25V)
MFA0300 Intensive, Critical and Home Care
90 320 122 (28V) 360 (28V)
MFA0296 Home Care Ventilators 70 320 86 (28V) 340 (28V)
MFA0290 Home Care Ventilations 76 300 97 (28V) 340 (28V)
WIT
HO
UT
HO
USI
NG
MFA0208 Home Care, Bi-Level, naked 70 340 86 (28V) 380 (28V)
MFA0206 Home Care, Bi-Level, naked 79 320 108 (28V) 360 (28V)
MFA0205 Home Care, Bi-Level, naked 78 300 106 (28V) 350 (28V)
MFA0801 Cough Assistance +/- 85 700 +/- 105 (28V) 750 (28V)
MFA0800 Cough Assistance +/- 85 660 +/- 105 (28V) 750 (28V)
* Performance achieved with AIRFAN motor controller MFA0900 and nominal motor Ke.
INNOVATION
AIRFAN DESIGNS AND PRODUCES A FULL RANGE OF PRODUCTS COVERING ALL THE RESPIRATORY APPLICATIONS NEEDS
SOUNDPROOFED CENTRIFUGAL BLOWERS FOR HOSPITAL, EMERGENCY, TRANSPORT AND HOME CARE VENTILATORS
AIRFAN’S CENTRIFUGAL BLOWERS OFFERING RELIABILITY, HIGH EFFICIENCY, PEACEFULNESS
AIRFAN is at the origin and owns many patents coming from its R&D Center which guarantee its customers the best performance available on the market:
Suspension and soundproofing of centrifugal blowers for respiratory devices.
Solution for cooling the electric motor driving a blower.
Separation of the electrical parts from the patient circuit so that high FiO2 can be used in the respirator.
All of the aeraulic parts are designed and sized by our experts’ teams with depth of experience in turbo machines. The geometry of the all parts of the blower is optimized to meet the needs of each application.
Allow to get:
Soundproofed machines
Reduced size of the batteries
Greatly reduced weight & dimensions
Providing independence, mobility and better comfort for the patient.
![Page 3: HIGH PERFORMANCE CENTRIFUGAL BLOWERS · AIRFAN is at the origin and owns many patents coming from its R&D Center which guarantee its customers the best performance available on the](https://reader035.vdocuments.us/reader035/viewer/2022062510/61221974608db5393774c9ca/html5/thumbnails/3.jpg)
NEW – MFA0900 MOTOR CONTROLLER DEVELOPMENT PLATFORM
Thanks to its innovative design the Inverter can drive high speed low inductance brushless motors with outstanding energy effi ciency.
The MFA0900 technology:
IncreasesperformanceforAIRFANblowersuchasriseandfalltimeaslowas30msand200bpm.
Providesenergysavings.
Reducesmotortemperature.
ExtendsblowerlifedurationandfacilitatesforVentilatormanufacturerstheintegrationofPressure/Flowcontrolloopensuringthatmaximumblowercapabilitiesareachieved.
Allowstopredictthelifetimeexpectationofabloweraccordingtoitsuse.
Patented cooling systemofferinglongerlifetimeexpectation.
Up to 100 hPaat120l/mn.
Compatible and securewithupstreamoxygenuse:absoluteseparationbetweentheelectricalpartsandthepatientcircuitallowinguseofoxygenat100%FiO2fortheMFA0500,MFA0296,MFA0208models.
Proven reliabilitywithpatientsbeingtreated24/7and365days/year.
Totally soundproofedsolution.
Rise timetosupportthepatient’sbreathingcycles.
SOUNDPROOFED CENTRIFUGAL BLOWERS FOR HOSPITAL, EMERGENCY, TRANSPORT AND HOME CARE VENTILATORS
MFA0114
MFA0500
MFA0300
MFA0205
MFA0800
MFA0208
![Page 4: HIGH PERFORMANCE CENTRIFUGAL BLOWERS · AIRFAN is at the origin and owns many patents coming from its R&D Center which guarantee its customers the best performance available on the](https://reader035.vdocuments.us/reader035/viewer/2022062510/61221974608db5393774c9ca/html5/thumbnails/4.jpg)
www.airfan.fr
AIRFAN is ISO9001 and ISO13485 certifiedandisperfectlysuitedtomeetthequalityandcostoptimizationrequirementscomingfrommanufacturersofmedicalequipment.Tensofthousandsofourturbinesoperate24/7,365days/yearattheheartofdemandinghealthcarerespirators.
ISO 13485 ISO 9001
the breath of performance
ZI En Jacca9 Chemin de la Salvetat 31770 COLOMIERS FranceTel : + 33 (0)5 34 50 45 50
CONTACT:Laurent [email protected]
© 2
019
AIR
FAN
– C
once
ptio
n et
réa
lisat
ion
: Aud
rey
Leco
nnét
able
– P
hoto
: Suk
i Édi
tions
, Fot
olia
– Im
pres
sion
: Im
prim
erie
Trè
fle.