high performance based design for the building envelope€¦ · • percent of lighting energy...
TRANSCRIPT
![Page 1: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/1.jpg)
High Performance Based Design for the Building Envelope
Fenestration Committee J. Deringer
J. Valancius
E. Nahman
B. Coffey
![Page 2: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/2.jpg)
Energy Use in Buildings
Source: LBNL windows research summary, Selkowitz etal
![Page 3: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/3.jpg)
Fenestration Impacts on End Use Energy
Source: LBNL windows research summary, Selkowitz etal
![Page 4: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/4.jpg)
Fenestration Impacts on Energy Use
Heating23%
Cooling13%
Lighting18%
Ventilation3%
Water Heating10%
Electronics7%
Appliances12%
Computers2%
Other12%
Has Impact on 57% of
Loads
• 133 Billion $/yr.• 13.9% US
EnergySource: LBNL windows research summary, Selkowitz etal
![Page 5: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/5.jpg)
Energy Performance Context • Fenestration is often considered “…the biggest hurdle ...”
to achieving significantly higher levels of energy efficiency for the building envelope.
• However, this negative assessment ignores two important sources of energy efficiency for fenestration:
• Integration of Systems
• Research and Development (R&D) opportunities
![Page 6: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/6.jpg)
Integration of Systems• Substantial energy efficiencies possible when fenestration
is integrated with other building systems:
• Daylighting (envelope, lighting, interiors, and controls)
• Natural ventilation (envelope, HVAC, controls)
• Integration of envelope and ventilation portions of HVAC systems
![Page 7: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/7.jpg)
Research & Development (R&D)• Significant new energy efficiency potential has been
identified over the next decade from several areas of fenestration research at research programs at Lawrence Berkeley National Laboratory (LBNL) and elsewhere:
• Advanced, Integrated Daylighting
• Affordable Dynamic windows (electro-chromic)
• Dynamic shading and glare control devices
• Commercialize Cost Effective R5 Windows
• Develop Next Generation of R10 Windows
![Page 8: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/8.jpg)
Electrochromic Windows R&D over past 10 years
![Page 9: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/9.jpg)
Fenestration Attributes and Sub Attributes • Thermal transfer
• U-Factor• SHGC – fenestration assembly• SHGC – fenestration + fixed shades• SHGC – fenestration + dynamic shades
• Daylighting • Percent of building floor area covered• Perimeter zone depth• Percent of lighting energy reduction
• Natural Ventilation
![Page 10: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/10.jpg)
Benchmarks-Metrics• U-Factor for Fenestration Assembly
![Page 11: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/11.jpg)
Benchmarks-Metrics-SHGC• Solar Heat Gain Coefficient (SHGC)
for Fenestration Assembly
![Page 12: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/12.jpg)
Benchmarks-Metrics-Daylighting• Basic and Advanced Versions• Integrated with other building systems• Building form, envelope, lighting, interiors, controls• Heating and cooling impacts vary by climate location
Based upon LBNL Research program estimates and upon EnergyPlus simulations
![Page 13: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/13.jpg)
Outcomes - EnergyPlus (E+) Simulations• Develop Parametric Processor for Simulation of Whole-
Building impacts• Start with building prototypes from PNNL
• Develop single medium office file for controlled parametric
• Start with baselines for ASHRAE/IES 90.1-2004 and 90.1-2010
• Simulate whole-building energy impacts of improved envelope performance measures
• Current results preliminary
![Page 14: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/14.jpg)
E+ Simulations – Climate Locations• 7 cities across moist climate zones 1 thru 7, Eastern US & CA
• 5 cities across dry climate zones 2 thru 6, Mountain US & CA
• 3 cities across coastal marine climate zones 3 thru 5.
![Page 15: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/15.jpg)
Basic E+ Simulation Results – 90.1-2004 to 2010Key measures - Basic Daylighting and Continuous Air Barriers
![Page 16: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/16.jpg)
E+ Advanced Daylighting, HP Glass, & Dynamic Shades
![Page 17: High Performance Based Design for the Building Envelope€¦ · • Percent of lighting energy reduction • Natural Ventilation . Benchmarks-Metrics • U-Factor for Fenestration](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e46c06b04ad1a54ee60ccaf/html5/thumbnails/17.jpg)
Discussion