![Page 1: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/1.jpg)
Since 1976
(Z660)www.texmate.com
HIGH ACCURACYLEGENDARY RELIABILITY
FAST DELIVERYFRIENDLY APPLICATION SUPPORT
POWER TRANSDUCERS
APR-17, 2017
![Page 2: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/2.jpg)
Since 1976
(Z670)www.texmate.com 2
Model# Input signal Maximum Range Accu-
TT-1S1MTTM-2S2MMTTM-2S2MCTT-2D2MMTT-2D2MC
Thermocouple J -50 to 1000°C (-58 to 1832°F) ±1°C
Thermocouple K -50 to 1370°C (-58 to 2498°F) ±1°C
Thermocouple T -270 to 400°C (-454 to 752°F) ±1°C
Thermocouple E -50 to 700°C (-58 to 1292°F) ±1°C
Thermocouple B 0 to 1750°C (32 to 3182°F) ±2°C *
Thermocouple R -50 to 1750°C (-58 to 3182°F) ±2°C
Thermocouple S -50 to 1750°C (-58 to 3182°F) ±2°C
Thermocouple N -50 to 1300°C (-58 to 2372°F) ±2°C
Thermocouple C -50 to 1800°C (-58 to 3272°F) ±2°C
Pt100 -200 to 600°C (-328 to ±0.2°C
MV -60mV to 60mV
Voltage -10 to 10Vdc ±1mV
Current 0 to 24mAdc ±10μA
LEOPARD TL SERIESTT SERIES
Remote Display Programmer
Isolated Analog Output
Leopard Transmitter
Power
Relay Output Input Signal
Output signal : DC 4/0~20mA or DC 0~10VOutput resolution : 0.6uA.Output response time : <200mS.Communication : Modbus RS-485 RTU protocol, 4800~38400 bpsPower supply : 18~36 Vdc, internal protection against polarity inversion
*Accuracy is not guaranteed between 0 and 400°C (0 and 752°F) for type B, R and S.
TT-1S1M Single Channel input and Single 4-20mA output
TTM-2S2MM Dual same signal Inputs; Single 4-20mA output and Single 4-20mA output with Math Function
TTM-2S2MC Dual same signal Inputs; Single 4-20mA output with math function & Single RS-485 output
TT-2D2MM Dual Inputs; Dual 4-20mA output
TT-2D2MC Dual Inputs; Single 4-20mA & Single RS-485 output
4 Active, isolated analog output. (No need of external 24V to power output)
4 Plug n Play. Order unit setup to your exact requirements.
4 Dual 9A Form C relays with NO and NC connections available.
4 24 VDC Excitation to power 4-20 mA loops and selectable 5 or 10 VDC to power Strain gauge, and Pressure / Load cell.
4 Auto sensing AC/DC power supply 85-265 VAC / 95-370 VDC or optional 18-36 VAC / 9-60 VDC.
4 Remote programmer may be used as a remote display.
Available Inputs: 4 DC - Volts, Amps, mV, mA4 AC - Volts, Amps, mV, mA,
Line Frequency4 Load Cell, Pressure, Strain
Gauge4 3 wire Potentiometer -
Position, Resistance4 Temperature - Thermocouple,
RTD Pt-1004 Proximity switch - RPM or
Frequency
E469078
Texmate DIN Rail Mount Transmitters
Transmitters can be configurated using TT Configurator software without connecting to a power source.
![Page 3: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/3.jpg)
Since 1976
(Z670)www.texmate.com 3
Contents
TA-1 & TA-1T ...................... AC CURRENT TRANSDUCERS Single Phase. ..... 4-5TA-3 & TA-3T ...................... AC CURRENT TRANSDUCERS Three Phase. ...... 4-5 TV-1 & TV-1T ...................... AC VOLTAGE TRANSDUCERS Single Phase. .......6-7 TV-3 & TV-3T ...................... AC VOLTAGE TRANSDUCERS Three Phase. ........6-7 TW-12 & TW-13................... Watts TRANSDUCERS Single Phase . .................. 8-9TW33 & TW-34 ................... Watts TRANSDUCERS Three Phase. .................... 8-9
TQ-12 & TQ-13 ................... VARs TRANSDUCERS Single Phase . ...............10-11TQ-33 & TQ-34 ................... VARs TRANSDUCERS Three Phase . ................10-11
TWQ-12 & TWQ-13 ............. Watts + VARs TRANSDUCERS Single Phase . .12-13TWQ-33 & TWQ-34 ............ Watts + VARs TRANSDUCERS Three Phase ...12-13
TWH-12 & TWH-13 ............. Watt Hours TRANSDUCERS Single Phase . .....14-15TWH-33 & TWH-34 ............ Watt Hours TRANSDUCERS Three Phase . ......14-15
TWWH-12 & TWWH-13 ...... Watt+Watt Hours TRANSDUCERS Single Phase . 16-17TWWH-33 & TWWH-34 ..... Watt + Watt Hours TRANSDUCERS Three Phase . 16-17
TQH-12 & TQH-13 ............. VAR Hours TRANSDUCERS Single Phase . ......18-19TQH-33 & TQH-34 ............. VAR Hours TRANSDUCERS Three Phase . .......18-19
TQQH-12 & TQQH-13 ........ VARs+VAR Hours TRANSDUCERS Single Phase . 20-21TQQH-33 & TQQH-34 ........ VARs+VAR Hours TRANSDUCERS Three Phase . 20-21
TPF-12 ................................. AC Power Factor TRANSDUCERS Single Phase . 22-23TPF-33 & TPF-34 ............... AC Power Factor TRANSDUCERS Three Phase . 22-23
TF-1 ..................................... FREQUENCY TRANSDUCERS . ......................... 24-25
TD-1 .................................... DC Volts or mA TRANSMITTER ISOLATOR . ... 26-27
CASE DIMENSIONS - CASE A & C. ......................................................................28
CASE DIMENSIONS - CASE B & D. ......................................................................29
![Page 4: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/4.jpg)
Since 1976
(Z670)www.texmate.com 4
MODELS OFFERED
FEATURES
AC CURRENT TRANSDUCER
TA-1: 1 Phase, Average sensing AmpsTA-1T: 1 Phase, True rms sensing Amps
TA-3: 3 Phase, Average sensing AmpsTA-3T: 3 Phase, True rms sensing Amps
• High accuracy ±0.2% of Rated Output (R.O.)• Super high accuracy ±0.1% of Rated Output (R.O.) available as a special order.*• High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277)• Many input and output signal combinations
GENERAL SPECIFICATIONSAccuracy ................................... ± 0.2% R.O. Standard for 10 to 100% of rated output
± 0.1% R.O. (Special Option)Temp. coefficient ..................... ≤100ppm/ºC of span
≤60ppm/ºC for ambient temperature of 25ºC ±10ºCTemp. range .............................. Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF)
Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)Humidity range ........................ Up to 95% RH non condensingIsolation .................................... Between Input/Output/Power/CaseDielectric test ........................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ................................. DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ............. Greater than 100 M Ω at 500V DCHousing material ..................... ABS Resin(94V-0) or metalMounting ................................... Screw mount on metal case or Plastic case DIN Rail 35mmAuxiliary Power ........................ AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional) 125V DC ± 20%(optional)
TA
• True RMS sensing is recommended for input signals with distortion. • Direct connect to the transducer for inputs ≤ 5A AC.
• Connect using a current Transformer (C.T.) for inputs greater than 5A AC.
![Page 5: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/5.jpg)
Since 1976
(Z670)www.texmate.com 5
AC CURRENT TRANSDUCERS
1 2 3 4
5 6 7 8
OUTPUT INPUT
POWER
+
230 V115 V
LineNeutral
OUTPUT+
INPUT SPECIFICATIONSAC Input ................................... 0 to 5A AC, 0 to 1A AC or custom inputFrequency ................................. 45Hz to 65Hz or 400HzBurden ...................................... ≤0.2VAResponse Sensitivity .............. ≤0.5% of measuring range to maximum input rangeInput Overload Capacity ......... 3 times the rated input current continuously.
10 times the rated current for 10 seconds. 50 times the rated input current for 1 second. 80 times the rated input current for 0.5 second.
OUTPUT SPECIFICATIONSOutput Variables ..................... DC mA or DC VoltsRipple ........................................ < 0.5% of rated output. Peak to Peak (maximum)Response Time ........................ < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ...................... ± 5% of rated output (minimum)Span Adjustment ..................... ± 10% of rated output (minimum)Load Resistance ...................... 10K Ω maximum for 0 to 1mA output
500 Ω maximum for 4 to 20mA output 500 Ω minimum for 0 to 10V output
CONNECTION DIAGRAM
TA-1/TA-1TA INPUT B INPUT C INPUT
+OUTPUT
BOUTPUT
A +OUTPUT
C+
+ + +
ACPOWER230 V
115 V
L2L1
L3
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TA-3/TA-3T
TA
TA-1
1 Ph
ase,
Avg
sen
sing
Am
psR
O1
±0.2
%
SA1
0 to
5 A
AC
HZ1
45H
z to
65H
zO
A1
0 to
1 m
A D
C
P1P011
5/23
0V A
C ±1
5%
Sing
le P
ower
ed0-
1 m
A O
utpu
t Onl
yC
MM
etal
TA
-1T
1 Ph
ase,
TRM
S se
nsin
g A
mps
RO
3±0
.1%
SA2
0 to
1 A
AC
HZ4
400H
zO
A2
4 to
20m
A D
C
P224
V D
C ±1
5%
CP
Plas
ticTA
-33
Phas
e, A
vg s
ensi
ng A
mps
SAY
Cust
om In
put
OA
30
to 1
0 V
DC
P312
5V D
C ±1
5%TA
-3T
3 Ph
ase,
TRM
S se
nsin
g A
mps
OA
YCu
stom
Out
put
Cust
om P
ower
±15
%
Inpu
t Fre
quen
cyBa
se M
odel
Case
Inpu
t Sig
nal
Out
put S
igna
lA
uxili
ary
Pow
erA
ccur
acy
PY
![Page 6: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/6.jpg)
Since 1976
(Z670)www.texmate.com 6
AC VOLTAGE TRANSDUCERS
MODELS OFFERED
FEATURES
TV-1: 1 Phase, Average sensingTV-1T: 1 Phase, True rms sensing
TV-3: 3 Phase, Average sensingTV-3T: 3 Phase, True rms sensing
• High accuracy ±0.2% of Rated Output (R.O.)• Super high accuracy ±0.1% of Rated Output (R.O.) available as a special order.*• High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277)• Many input and output signal combinations
GENERAL SPECIFICATIONS
TV
• True RMS sensing is recommended for input signals with distortion. • Direct connect to the transducer for inputs ≤ 600V AC.• Connect using a Potential Transformer (P.T.) for inputs > 600V AC.
Accuracy ................................... ± 0.2% R.O. Standard for 10 to 100% of rated output ± 0.1% R.O. (Special Option)
Temp. coefficient ..................... ≤100ppm/ºC of span ≤60ppm/ºC for ambient temperature of 25ºC ±10ºC
Temp. range .............................. Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF) Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)
Humidity range ........................ Up to 95% RH non condensingIsolation .................................... Between Input/Output/Power/CaseDielectric test ........................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ................................. DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ............. Greater than 100 M Ω at 500V DCHousing material ..................... ABS Resin(94V-0) or metalMounting ................................... Screw mount on metal case or Plastic case DIN Rail 35mmAuxiliary Power ........................ AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional) 125V DC ± 20%(optional)
![Page 7: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/7.jpg)
Since 1976
(Z670)www.texmate.com 7
AC VOLTAGE TRANSDUCERS
INPUT SPECIFICATIONSAC Input ............................... 0 to 150V AC, 0 to 300V AC, 0 to 600V AC or custom inputFrequency ........................... 45Hz to 65Hz or 400HzBurden ................................. ≤0.1VAResponse Sensitivity ......... ≤0.5% of measuring range to mazimum input rangeInput Overload Capacity .... 1.25 times the rated input voltage continuously.
2 times the rated voltage for 10 seconds. 4 times the rated input voltage for 5 seconds. Or 600V AC rms continuous.(absolute maximum)
OUTPUT SPECIFICATIONS
Output Variables ................. DC mA or DC VoltsRipple ................................... < 0.5% of rated output. Peak to Peak (maximum)Response Time ................... < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ................. ± 5% of rated output minimumSpan Adjustment ................ ± 10% of rated output minimumLoad Resistance ................. 10K Ω maximum for 0 to 1mA output
500 Ω maximum for 4 to 20mA output 500 Ω minimum for 0 to 10V output
CONNECTION DIAGRAM
TV-1/TV-1T
1 2 3 4
5 6 7 8
OUTPUT INPUT
P.T.
POWER
+
230 V115 V
LineNeutralOUTPUT+
1S 1L 2S 2L 3S 3L
+OUTPUT
AOUTPUT
C+
+
+OUTPUT
B
+ +
ACPOWER230 V
115 V
L2L3
L1
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 181S 1L 2S 2L 3S 3L
+OUTPUT
BOUTPUT
A +OUTPUT
C+
+ + +
ACPOWER230 V
115 V
L3N
L2L1
P.T.1 P.T.2 P.T.3
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
Three Phase 3 wire Three Phase 4 wire TV-1
1 Ph
ase,
Avg
sen
sing
Vol
tsR
O1
±0.2
%SV
10
to 1
50V
AC
HZ1
45H
z to
65H
zO
V10
to 1
mA
DC
CM
Met
alTV
-1T
1 Ph
ase,
TRM
S se
nsin
g Vo
ltsR
O3
±0.1
%SV
20
to 3
00V
AC
HZ4
400H
zO
V24
to 2
0mA
DC
CP
Plas
ticTV
-33
Phas
e, A
vg s
ensi
ng V
olts
SV3
0 to
600
V A
CO
V30
to 1
0 V
DC
TV-3
T3
Phas
e, T
RMS
sens
ing
Volts
SVY
Cust
om In
put
OVY
Cust
om O
utpu
t
Inpu
t Fre
quen
cyBa
se M
odel
Inpu
t Sig
nal
Case
Aux
iliar
y Po
wer
Out
put S
igna
lA
ccur
acy
P1P011
5/23
0V A
C ±1
5%Si
ngle
Pow
ered
P224
V D
C ±1
5%
P312
5V D
C ±1
5%Cu
stom
Pow
er ±
15%
PY
TV
![Page 8: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/8.jpg)
Since 1976
(Z670)www.texmate.com 8
MODELS OFFERED
FEATURES
Watts TRANSDUCERS
TW-12: Single Phase, 2 Wire – 1 ElementTW-13: Single Phase, 3 Wire – 2 ElementTW-33: 3 Phase, 3 Wire – 2 ElementTW-34: 3 Phase, 4 Wire – 3 Element
• Accurate measurement of the active power Watts for bal-anced or unbalanced loads.
• The output signals are isolated load independent DC mA or DC Volts, representing the measured value of the active power Watts.
• Uses Time Division Multiplication (TDM) for precision measurement of even distorted signals.• High accuracy ±0.2% of Rated Output (R.O.)• Super high accuracy ±0.1% of Rated Output (R.O.) available as a special order.*• High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277) or screw mounting.• Many input and output signal combinations
GENERAL SPECIFICATIONS
Accuracy ................................... ± 0.2% R.O. Standard for 10 to 100% of rated output ± 0.1% R.O. (Special Option)
Temp. coefficient ..................... ≤100ppm/ºC of span ≤60ppm/ºC for ambient temperature of 25ºC ±10ºC
Temp. range .............................. Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF) Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)
Humidity range ........................ Up to 95% RH non condensingIsolation .................................... Between Input/Output/Power/CaseDielectric test ........................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ................................. DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ............. Greater than 100 M Ω at 500V DCHousing material ..................... ABS Resin(94V-0) or metalMounting ................................... Screw mount on metal case or Plastic case DIN Rail 35mmAuxiliary Power ........................ AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional) 125V DC ± 20%(optional)
TW
![Page 9: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/9.jpg)
Since 1976
(Z670)www.texmate.com 9
INPUT SPECIFICATIONSAC Input .................................... 120V/5A AC, 240V/5A AC for 1ø/2 wire, 240V/120V, 5A AC for 1ø/ 3 Wire
120V/5A AC, 240V/5A AC for 3ø/3 Wire & 3ø / 4 Wire custom input (600V max /10A AC max)
Frequency ................................. 60Hz ±3Hz, 50Hz ±3Hz, 400Hz ±3Hz Burden ...................................... ≤0.2VA per current circuit, ≤0.1VA per voltage circuit.Response Sensitivity .............. ≤0.5% of measuring range to maximum input rangeInput Voltage ............................ 600V AC rms continuous (absolute maximum)
Overload Capacity 1.25 times the rated input Voltage continuously. 2 times the rated input Voltage for 10 secs. 4 times the rated input Voltage for 5 secs.
Input Current ............................ 3 times the rated input current continuously. Overload Capacity 10 times the rated input current for 10 secs. 50 times the rated input current for 1 sec. 80 times the rated input current for 0.5 secs
OUTPUT SPECIFICATIONSOutput Variables ...................... DC mA or DC VoltsRipple ........................................ < 0.5% of rated output. Peak to Peak (maximum)Response Time ........................ < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ...................... ± 5% of rated output (minimum)Span Adjustment ..................... ± 10% of rated output (minimum)Load Resistance ...................... 10 kΩ maximum for 0 to 1mA output
500 Ω maximum for 4 to 20mA output 500 Ω minimum for 0 to 10V output
Maximum Input range value = (CT Ratio) X (PT Ratio) X (Nominal Watts)If CT = 200A:5A PT is 3300V:110V Nominal Watts = 500 then CT Ratio = 40 then PT Ratio = 30 and Maximum input range value = 40 x 30 x 500 = 600KW
Watts TRANSDUCERS
+OUTPUT
OUTPUT+
ACPOWER230 V
115 V
LC.T.1
P.T.1
N
1S 1L
P1 P21 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
+OUTPUT
OUTPUT+
ACPOWER230 V
115 V
L1 C.T.1
P0 P2P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.2
L2N
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
+OUTPUT
OUTPUT+
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
L2L3
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
+OUTPUT
OUTPUT+
ACPOWER230 V
115 V
L1C.T.1
P2 P3P1P0
1S 1L 2S 2L 3S 3L
C.T.3C.T.2
P.T.
2
P.T.
1
P.T.
3
L2L3N
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
CONNECTION DIAGRAM
TW-1
21
Phas
e, 1
P/2W
, 1E,
Wat
tsR
O1
±0.2
%SW
112
0V/5
A A
CH
Z660
Hz
OW
10
to 1
mA
DC
CM
Met
alTW
-13
1 Ph
ase,
1P/
3W, 2
E, W
atts
RO
3±0
.1%
SW2
240V
/5A
AC
HZ5
50H
zO
W2
4 to
20m
A D
CC
PPl
astic
TW-3
33
Phas
e, 3
P/3W
, 2E,
Wat
tsSW
YCu
stom
Inpu
t, M
AX
10A
HZ4
400H
zO
W3
0 to
10
V D
CTW
-34
3 Ph
ase,
3P/
4W, 3
E, W
atts
OW
YCu
stom
Out
put
Base
Mod
el
Case
Aux
iliar
y Po
wer
Inpu
t Sig
nal
Out
put S
igna
lA
ccur
acy
Inpu
t Fre
quen
cy
P1P011
5/23
0V A
C ±1
5%Si
ngle
Pow
ered
P224
V D
C ±1
5%
P312
5V D
C ±1
5%Cu
stom
Pow
er ±
15%
PY
TW
TW-12 TW-13
TW-33 TW-34
![Page 10: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/10.jpg)
Since 1976
(Z670)www.texmate.com 10
MODELS OFFERED
FEATURES• Uses Time Division Multiplication (TDM) for precision measurement of even distorted signals.• High accuracy ±0.2% of Rated Output (R.O.)• Super high accuracy ±0.1% of Rated Output (R.O.) available as a special order.*• High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277) or screw mounting.• Many input and output signal combinations
VARs TRANSDUCERS
TQ-12: Single Phase, 2 Wire – 1 Element
TQ-13: Single Phase, 3 Wire – 2 Element
TQ-33: 3 Phase, 3 Wire – 2 Element
TQ-34: 3 Phase, 4 Wire – 3 Element
• Accurate measurement of the active power Watts for balanced or unbalanced loads.
• The output signals are isolated load independent DC mA or DC Volts, representing the measured value of the active power Watts.
GENERAL SPECIFICATIONSAccuracy ................................... ± 0.2% R.O. Standard for 10 to 100% of rated output
± 0.1% R.O. (Special Option)Temp. coefficient ..................... ≤100ppm/ºC of span
≤60ppm/ºC for ambient temperature of 25ºC ±10ºCTemp. range .............................. Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF)
Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)Humidity range ........................ Up to 95% RH non condensingIsolation .................................... Between Input/Output/Power/CaseDielectric test ........................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ................................. DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ............. Greater than 100 M Ω at 500V DCHousing material ..................... ABS Resin(94V-0) or metalMounting ................................... Screw mount on metal case or Plastic case DIN Rail 35mmAuxiliary Power ........................ AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional) 125V DC ± 20%(optional)
TQ
![Page 11: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/11.jpg)
Since 1976
(Z670)www.texmate.com 11
OUTPUT SPECIFICATIONSOutput Variables ...................... DC mA or DC VoltsRipple ........................................ < 0.5% of rated output. Peak to Peak (maximum)Response Time ........................ < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ...................... ± 5% of rated output (minimum)Span Adjustment ..................... ± 10% of rated output (minimum)Load Resistance ...................... 10 kΩ maximum for 0 to 1mA output
500 Ω maximum for 4 to 20mA output 500 Ω minimum for 0 to 10V output
Maximum Input range value = (CT Ratio) X (PT Ratio) X (Nominal VARs)If CT = 200A:5A PT is 3300V:110V Nominal VARs = 500 CT Ratio = 40 PT Ratio = 30 and Maximum input range value = 40 x 30 x 500 = 600KVAR
VARs TRANSDUCERS
INPUT SPECIFICATIONSAC Input .................................... 120V/5A AC, 240V/5A AC for 1ø/2 wire, 240V/120V, 5A AC for 1ø/ 3 Wire
120V/5A AC, 240V/5A AC for 3ø/3 Wire & 3ø / 4 Wire custom input (600V max /10A AC max)
Frequency ................................. 60Hz ±3Hz, 50Hz ±3Hz, 400Hz ±3Hz Burden ...................................... ≤0.2VA per current circuit, ≤0.1VA per voltage circuit.Response Sensitivity .............. ≤0.5% of measuring range to maximum input rangeInput Voltage ............................ 600V AC rms continuous (absolute maximum)
Overload Capacity 1.25 times the rated input Voltage continuously. 2 times the rated input Voltage for 10 secs. 4 times the rated input Voltage for 5 secs.
Input Current ............................ 3 times the rated input current continuously. Overload Capacity 10 times the rated input current for 10 secs. 50 times the rated input current for 1 sec. 80 times the rated input current for 0.5 secs
+OUTPUT
OUTPUT+
ACPOWER230 V
115 V
LC.T.1
P.T.1
N
1S 1L
P1 P21 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
+OUTPUT
OUTPUT+
ACPOWER230 V
115 V
L1 C.T.1
P0 P2P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.2
L2N
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
+OUTPUT
OUTPUT+
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
L2L3
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
+OUTPUT
OUTPUT+
ACPOWER230 V
115 V
L1C.T.1
P2 P3P1P0
1S 1L 2S 2L 3S 3L
C.T.3C.T.2
P.T.
2
P.T.
1
P.T.
3
L2L3N
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
CONNECTION DIAGRAM
TQ
TQ-1
21
Phas
e, 1
P/2W
, 1E,
VA
RsR
O1
±0.2
%SW
112
0V/5
A A
CH
Z660
Hz
OQ
4±1
mA
DC
LGLA
G =
+ P
olar
ityC
MM
etal
TQ-1
31
Phas
e, 1
P/3W
, 2E,
VA
RsR
O3
±0.1
%SW
224
0V/5
A A
CH
Z550
Hz
OQ
512
± 8
mA
DC
LDLE
AD
= +
Pola
rity
CP
Plas
ticTQ
-33
3 Ph
ase,
3P/
3W, 2
E, V
ARs
SWY
Cust
om In
put
HZ4
400H
zO
Q6
±10
V D
CTQ
-34
3 Ph
ase,
3P/
4W, 3
E, V
ARs
OQ
YCu
stom
Out
put
Case
Acc
urac
yIn
put F
requ
ency
Base
Mod
el
Aux
iliar
y Po
wer
Inpu
t Sig
nal
Out
put S
igna
lIn
put/
Out
put
Rela
tions
hip
P1P011
5/23
0V A
C ±1
5%Si
ngle
Pow
ered
P224
V D
C ±1
5%
P312
5V D
C ±1
5%Cu
stom
Pow
er ±
15%
PY
TQ-12
TQ-33 TQ-34
TQ-13
![Page 12: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/12.jpg)
Since 1976
(Z670)www.texmate.com 12
MODELS OFFERED
Watts + VARs TRANSDUCERS
TWQ-12: 1 Phase, 2 Wire – 1 ElementTWQ-13: 1 Phase, 3 Wire – 2 ElementTWQ-33: 3 Phase, 3 Wire – 2 ElementTWQ-34: 3 Phase, 4 Wire – 3 Element
• Uses Time Division Multiplication (TDM) for precision measurement of even distorted signals.• High accuracy ±0.2% of Rated Output (R.O.)• Super high accuracy ±0.1% of Rated Output (R.O.) available as a special order.*• High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277) or screw mounting.• Many input and output signal combinations
GENERAL SPECIFICATIONSAccuracy ................................... ± 0.2% R.O. Standard for 10 to 100% of rated output
± 0.1% R.O. (Special Option)Temp. coefficient ..................... ≤100ppm/ºC of span
≤60ppm/ºC for ambient temperature of 25ºC ±10ºCTemp. range .............................. Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF)
Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)Humidity range ........................ Up to 95% RH non condensingIsolation .................................... Between Input/Output/Power/CaseDielectric test ........................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ................................. DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ............. Greater than 100 M Ω at 500V DCHousing material ..................... ABS Resin(94V-0) or metalMounting ................................... Screw mount on metal case or Plastic case DIN Rail 35mmAuxiliary Power ........................ AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional), 125V DC ± 20%(optional)
FEATURES
TWQ
• Accurate measurement of the active power and reactive power (Watts and VARs) of a single/ three phase system with balanced or unbalanced loads.
• The output signals are isolated load independent DC mA or DC Volts, representing the measured value of the active and reactive power (Watts and VARs).
INPUT SPECIFICATIONSAC Input .................................... 120V/5A AC, 240V/5A AC for 1ø/2 wire, 240V/120V, 5A AC for 1ø/ 3 Wire
120V/5A AC, 240V/5A AC for 3ø/3 Wire & 3ø / 4 Wire custom input (600V max /10A AC max)
Frequency ................................. 60Hz ±3Hz, 50Hz ±3Hz, 400Hz ±3Hz Burden ...................................... ≤0.2VA per current circuit, ≤0.1VA per voltage circuit.Response Sensitivity .............. ≤0.5% of measuring range to maximum input rangeInput Voltage ............................ 600V AC rms continuous (absolute maximum)
Overload Capacity 1.25 times the rated input Voltage continuously. 2 times the rated input Voltage for 10 secs. 4 times the rated input Voltage for 5 secs.
Input Current ............................ 3 times the rated input current continuously. 10 times the rated input current for 10 secs. Overload Capacity 50 times the rated input current for 1 sec. 80 times the rated input current for 0.5 secs
![Page 13: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/13.jpg)
Since 1976
(Z670)www.texmate.com 13
OUTPUT SPECIFICATIONSOutput Variables ...................... DC mA or DC VoltsRipple ........................................ < 0.5% of rated output. Peak to Peak (maximum)Response Time ........................ < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ...................... ± 5% of rated output (minimum)Span Adjustment ..................... ± 10% of rated output (minimum)Load Resistance ...................... 10 kΩ maximum for 0 to 1mA output
500 Ω maximum for 4 to 20mA output 500 Ω minimum for 0 to 10V output
To calculate the actual Watts and VARs Maximum Input range value, the CT and PT ratios have to be factored inMaximum input Range for Watts = (CT Ratio) X (PT Ratio) X (Nominal Watts)Maximum Input range value for VARs = (CT Ratio) X (PT Ratio) X (Nominal VARs)
For example:If CT = 200A:5A PT is 3300V:110V Nominal Watts = 1000 Nominal VARs = 1000 then CT Ratio = 40 then PT Ratio = 30 and Maximum input range value for Watts = 40 x 30 x 1000 = 1200KWattsMaximum input range value for VARs = 40 x 30 x 1000 = 1200KVARs
Watts + VARs TRANSDUCERS
CONNECTION DIAGRAM
+WATT
OUTPUT
OUTPUT+
ACPOWER230 V
115 V
LC.T.1
P.T.1
N
1S 1L
P1 P2
+VAR
OUTPUT
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
+WATT
OUTPUT +VAE
OUTPUT
OUTPUT+
ACPOWER230 V
115 V
L1 C.T.1
P0 P2P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.2
L2
N
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TWQ-12 TWQ-13
OUTPUT+
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
L2
L3
+WATT
OUTPUT +VAR
OUTPUT
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
OUTPUT+
ACPOWER230 V
115 V
L1C.T.1
P2 P3P1P0
1S 1L 2S 2L 3S 3L
C.T.3C.T.2
P.T.
2
P.T.
1
P.T.
3
L2
L3
N
+WATT
OUTPUT +VAR
OUTPUT
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TWQ-33 TWQ-34
TWQ
TWQ
-12
1 Ph
ase,
1P/
2W, 1
E, W
att +
VA
RsR
O1
±0.2
%SW
112
0V/5
A A
CH
Z660
Hz
OW
V1W
atts
0 to
1 m
A D
CVA
Rs ±
1mA
DC
LGLA
G =
+ P
olar
ityC
MM
etal
TWQ
-13
1 Ph
ase,
1P/
3W, 2
E, W
att +
VA
RsR
O3
±0.1
%SW
224
0V/5
A A
CH
Z550
Hz
OW
V2W
atts
4 to
20m
A D
CVA
Rs 1
2 ±
8mA
DC
LDLE
AD
= +
Pola
rity
CP
Plas
tic
TWQ
-33
3 Ph
ase,
3P/
3W, 2
E, W
att +
VA
RsSW
YCu
stom
Inpu
tH
Z440
0Hz
OW
V5W
atts
12
± 8m
A D
CVA
Rs 1
2 ±
8mA
DC
TWQ
-34
3 Ph
ase,
3P/
4W, 3
E, W
att +
VA
RsO
WV6
Wat
ts 0
to 1
0V D
CVA
Rs ±
10V
DC
Base
Mod
el
Acc
urac
yA
uxili
ary
Pow
erIn
put S
igna
lO
utpu
t Sig
nal
Inpu
t/O
utpu
tRe
latio
nshi
pCa
seIn
put F
requ
ency
P1P0
115/
230V
AC
±15%
Sing
le P
ower
ed0
+/- 1
mA
Out
put O
nly
P224
V D
C ±1
5%
P312
5V D
C ±1
5%Cu
stom
Pow
er ±
15%
PY
![Page 14: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/14.jpg)
Since 1976
(Z670)www.texmate.com 14
MODELS OFFEREDTWH-12: 1 Phase, 2 Wire – 1 ElementTWH-13: 1 Phase, 3 Wire – 2 ElementTWH-33: 3 Phase, 3 Wire – 2 ElementTWH-34: 3 Phase, 4 Wire – 3 Element
• Uses Time Division Multiplication (TDM) for precision measurement of even distorted signals.• High accuracy ±0.2% of Rated Output (R.O.)• Super high accuracy ±0.1% of Rated Output (R.O.) available as a special order.*• High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277) or screw mounting.• Many input and output signal combinations.
Watt Hours TRANSDUCERSTWH
• Accurate measurement of the active energy (Watt Hours) of a single phase system with balanced or unbalanced loads.
• The output signals are isolated load independent pulses, representing the measured value of the active energy (WattHours, forward and reverse).
GENERAL SPECIFICATIONSAccuracy ................................... ± 0.2% R.O. Standard for 10 to 100% of rated output
± 0.1% R.O. (Special Option)Temp. coefficient ..................... ≤100ppm/ºC of span
≤60ppm/ºC for ambient temperature of 25ºC ±10ºCTemp. range .............................. Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF)
Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)Humidity range ........................ Up to 95% RH non condensingIsolation .................................... Between Input/Output/Power/CaseDielectric test ........................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ................................. DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ............. Greater than 100 M Ω at 500V DCHousing material ..................... ABS Resin(94V-0) or metalMounting ................................... Screw mount on metal case or Plastic case DIN Rail 35mmAuxiliary Power ........................ AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional), 125V DC ± 20%(optional)
FEATURES
INPUT SPECIFICATIONSAC Input .................................... 120V/5A AC, 240V/5A AC for 1ø/2 wire, 240V/120V, 5A AC for 1ø/ 3 Wire
120V/5A AC, 240V/5A AC for 3ø/3 Wire & 3ø / 4 Wire custom input (600V max /10A AC max)
Frequency ................................. 60Hz ±3Hz, 50Hz ±3Hz, 400Hz ±3Hz Burden ...................................... ≤0.2VA per current circuit, ≤0.1VA per voltage circuit.Response Sensitivity .............. ≤0.5% of measuring range to maximum input rangeInput Voltage ............................ 600V AC rms continuous (absolute maximum)
Overload Capacity 1.25 times the rated input Voltage continuously. 2 times the rated input Voltage for 10 secs. 4 times the rated input Voltage for 5 secs.
Input Current ............................ 3 times the rated input current continuously. 10 times the rated input current for 10 secs. Overload Capacity 50 times the rated input current for 1 sec. 80 times the rated input current for 0.5 secs
![Page 15: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/15.jpg)
Since 1976
(Z670)www.texmate.com 15
Watt Hours TRANSDUCERS
Output Variables ................. PulsesRipple ................................... < 0.5% of rated output. Peak to Peak (maximum)Response Time ................... < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ................. ± 5% of rated output (minimum)Span Adjustment ................ ± 10% of rated output (minimum)
To calculate the actual WattHours for each output pulse, the CT and PT ratios have to be factored in
WattHours per Output Pulse = (CT Ratio) X (PT Ratio) Nominal Pulses /WattHour
Calculation example: For Single phase 2 wire, TWH-12If CT = 200A:5A then CT Ratio = 40 PT is 3300V:110V then PT Ratio = 30
If 1 pulse per WattHour is selected, the output will actually be 1 pulse per 1200 WattHoursIf 10 pulse per WattHour is selected, the output will actually be 1 pulse per 120 WattHoursIf 100 pulse per WattHour is selected, the output will actually be 1 pulse per 12 WattHours
OUTPUT SPECIFICATIONS
CONNECTION DIAGRAM
TWH
OUTPUT+ +
ACPOWER230 V
115 V
L C.T.1
P2P1
1S 1L 3S 3L
P.T.1
N
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TWH-12
TWH-33
TWH-13
TWH-34
OUTPUT+ +
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
N
L2
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
L2
L3
OUTPUT+ +
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
ACPOWER230 V
115 V
L1C.T.1
P2 P3P1P0
1S 1L 2S 2L 3S 3L
C.T.3C.T.2
P.T.
2
P.T.
1
P.T.
3
L2
L3
N
OUTPUT+ +
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TWH
-12
1 Ph
ase,
1P/
2W, 1
E, W
atth
ours
RO1
±0.2
%SW
112
0V/5
A A
CH
Z660
Hz
OR1
Reed
Rel
ay.
P111
5/23
0 VA
C ±1
5%PU
11
puls
e pe
r WH
CM
Met
al
TWH
-13
1 Ph
ase,
1P/
3W, 2
E, W
atth
ours
RO3
±0.1
%SW
224
0V/5
A A
CH
Z550
Hz
OR2
Reed
Rel
ay.
Forw
ard
+ Re
vers
eP2
24 V
DC
±15%
PU2
10 P
ulse
s Pe
r WH
CP
Plas
tic
TWH
-33
3 Ph
ase,
3P/
3W, 2
E, W
atth
ours
SWY
Cust
om In
put
HZ4
400H
zO
C1
Ope
n Co
llect
or.
Forw
ard
only
P312
5 VD
C ±1
5%PU
310
0 pu
lses
per
WH
TWH
-34
3 Ph
ase,
3P/
4W, 3
E, W
atth
ours
OC
2O
pen
Colle
ctor
. Fo
rwar
d +
Reve
rse
PYCu
stom
Pow
er ±
15%
PU4
1 pu
lse
per 1
000W
H
Aux
iliar
y Po
wer
Puls
e pe
r Wat
tHou
rIn
put F
requ
ency
Case
Inpu
t Sig
nal
Out
put S
igna
lBa
se M
odel
A
ccur
acy
Forw
ard
only
![Page 16: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/16.jpg)
Since 1976
(Z670)www.texmate.com 16
MODELS OFFERED
FEATURES
TWWH-12 base model 1 Phase, 2 Wire – 1 Element TWWH-13 base model 1 Phase, 3 Wire – 2 Element TWWH-33 base model 3 Phase, 3 Wire – 2 Element TWWH-34 base model 3 Phase, 4 Wire – 3 Element
• Uses Time Division Multiplication (TDM) for precision measurement of even distorted signals.• High accuracy ±0.2% of Rated Output (R.O.)• Super high accuracy ±0.1% of Rated Output (R.O.) available as a special order.*• High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277) or screw mounting.• Many input and output signal combinations.
GENERAL SPECIFICATIONS
Watt+Watt Hours TRANSDUCERS TWWH
• Accurate measurement of the active energy (WattHours) of a three phase system with balanced or unbalanced loads.
• The output signals are isolated load independent pulses, represent-ing the measured value of the active energy (WattHours, forward and reverse) and DC mA or DC V for the active power (Watts).
Accuracy ................................... ± 0.2% R.O. Standard for 10 to 100% of rated output ± 0.1% R.O. (Special Option)
Temp. coefficient ..................... ≤100ppm/ºC of span ≤60ppm/ºC for ambient temperature of 25ºC ±10ºC
Temp. range .............................. Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF) Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)
Humidity range ........................ Up to 95% RH non condensingIsolation .................................... Between Input/Output/Power/CaseDielectric test ........................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ................................. DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ............. Greater than 100 M Ω at 500V DCHousing material ..................... ABS Resin(94V-0) or metalMounting ................................... Screw mount on metal case or Plastic case on DIN Rail 35mmAuxiliary Power ........................ AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional) 125V DC ± 20%(optional)
INPUT SPECIFICATIONSAC Input .................................... 120V/5A AC, 240V/5A AC. Custom input (600V max /10A AC max)Frequency ................................. 60Hz ±3Hz, 50Hz ±3Hz, 400Hz ±3Hz Burden ...................................... ≤0.2VA per current circuit, ≤0.1VA per voltage circuit.Response Sensitivity .............. ≤0.5% of measuring range to maximum input rangeInput Voltage ............................ 600V AC rms continuous (absolute maximum)
Overload Capacity 1.25 times the rated input Voltage continuously. 2 times the rated input Voltage for 10 secs. 4 times the rated input Voltage for 5 secs.
Input Current ............................ 3 times the rated input current continuously. Overload Capacity 10 times the rated input current for 10 secs. 50 times the rated input current for 1 sec. 80 times the rated input current for 0.5 secs
![Page 17: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/17.jpg)
Since 1976
(Z670)www.texmate.com 17
Watt+Watt Hours TRANSDUCERS
OUTPUT SPECIFICATIONSOutput Variables ................. Pulses (WattHours) and DC mA or DC V (Watts)Ripple ................................... < 0.5% of rated output. Peak to Peak (maximum)Response Time ................... < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ................. ± 5% of rated output (minimum)Span Adjustment ................ ± 10% of rated output (minimum)
To calculate the actual WattHours and Watts for each output pulse, the CT and PT ratios have to be factored in Watts = (CT Ratio) X (PT Ratio) x Nominal Watts
WattHours per Output Pulse = (CT Ratio) X (PT Ratio) Nominal Pulses /WattHour Calculation example: For Single phase 2 wire, TWWH-12If CT = 200A:5A then CT Ratio = 40 PT is 3300V:110V then PT Ratio = 30 Watts = 30 x 40 x 500 = 600kW
If 1 pulse per WattHour is selected, the output will actually be 1 pulse per 1200 WattHoursIf 10 pulse per WattHour is selected, the output will actually be 1 pulse per 120 WattHoursIf 100 pulse per WattHour is selected, the output will actually be 1 pulse per 12 WattHours
+ +
ACPOWER230 V
115 V
L C.T.1
P2P1
1S 1L 3S 3L
P.T.1
N
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
PULSEOUTPUT
+DC
OUTPUT
DCOUTPUT+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
CONNECTION DIAGRAM
PULSEOUTPUT
+ +
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
N
L2
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
+DC
OUTPUT
DCOUTPUT+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
L2
L3
PULSEOUTPUT
+ +
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
+DC
OUTPUT
DCOUTPUT
+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
ACPOWER230 V
115 V
L1C.T.1
P2 P3P1P0
1S 1L 2S 2L 3S 3L
C.T.3C.T.2
P.T.
2
P.T.
1
P.T.
3
L2
L3
N
PULSEOUTPUT
+ +
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
+DC
OUTPUT
DCOUTPUT
+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TWWH
TWWH-12 TWWH-13
TWWH-33 TWWH-34 TWW
H-1
21
Phas
e, 1
P/2W
, 1E,
W
atts
+Wat
thou
rsR
O1
±0.
2%SW
112
0V/5
A A
CH
Z660
Hz
OW
R1
Wat
ts 0
to 1
mA
DC
WH
r Ree
d Re
lay.
For
war
d on
ly
P111
5/23
0 VA
C ±1
5%PU
11
puls
e/W
HC
MM
etal
TWW
H-1
31
Phas
e, 1
P/3W
, 2E,
W
atts
+Wat
thou
rsR
O3
±0.1
%SW
224
0V/5
A A
CH
Z550
Hz
OW
R2
Wat
ts 4
to 2
0 m
A D
CW
Hr R
eed
Rela
y. F
orw
ard
and
Reve
rse
P224
VD
C ±1
5%PU
210
Pul
ses/
WH
CP
Plas
tic
TWW
H-3
33
Phas
e, 3
P/3W
, 2E,
W
atts
+Wat
thou
rsSW
YCu
stom
Inpu
tH
Z440
0Hz
OW
C1
Wat
ts 0
to 1
mA
DC
WH
r Ope
n Co
llect
or. F
orw
ard
only
P312
5 VD
C ±1
5%PU
310
0 pu
lses
/WH
TWW
H-3
43
Phas
e, 3
P/4W
, 3E,
W
atts
+Wat
thou
rsO
WC
2W
atts
4 to
20
mA
DC
WH
r Ope
n Co
llect
or. F
orw
ard
+ Re
vers
ePY
Cust
om P
ower
±1
5%PU
41
puls
e/10
00W
H
Acc
urac
yBa
se M
odel
Inpu
t Sig
nal
Out
put S
igna
lA
uxili
ary
Pow
erCa
sePu
lse
per W
attH
our
Freq
uenc
y
![Page 18: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/18.jpg)
Since 1976
(Z670)www.texmate.com 18
MODELS OFFEREDTQH-12: 1 Phase, 2 Wire – 1 ElementTQH-13: 1 Phase, 3 Wire – 2 ElementTQH-33: 3 Phase, 3 Wire – 2 ElementTQH-34: 3 Phase, 4 Wire – 3 Element
• Uses Time Division Multiplication (TDM) for precision measurement of even distorted signals.• High accuracy ±0.2% of Rated Output (R.O.)• Super high accuracy ±0.1% of Rated Output (R.O.) available as a special order.*• High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277) or screw mounting.• Many input and output signal combinations.
VAR Hours TRANSDUCERS TQH
• Accurate measurement of the reactive energy (VAR Hours) of a single phase system with balanced or unbalanced loads.
• The output signals are isolated load independent DC mA or DC Volts, representing the measured value of the active energy (WattHours, forward and reverse).
FEATURES
GENERAL SPECIFICATIONSAccuracy ................................... ± 0.2% R.O. Standard for 10 to 100% of rated output
± 0.1% R.O. (Special Option)Temp. coefficient ..................... ≤100ppm/ºC of span
≤60ppm/ºC for ambient temperature of 25ºC ±10ºCTemp. range .............................. Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF)
Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)Humidity range ........................ Up to 95% RH non condensingIsolation .................................... Between Input/Output/Power/CaseDielectric test ........................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ................................. DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ............. Greater than 100 M Ω at 500V DCHousing material ..................... ABS Resin(94V-0) or metalMounting ................................... Screw mount on metal case or Plastic case on DIN Rail 35mmAuxiliary Power ........................ AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional) 125V DC ± 20%(optional)
INPUT SPECIFICATIONSAC Input .................................... 120V/5A AC, 240V/5A AC. Custom input (600V max /10A AC max)Frequency ................................. 60Hz ±3Hz, 50Hz ±3Hz, 400Hz ±3Hz Burden ...................................... ≤0.2VA per current circuit, ≤0.1VA per voltage circuit.Response Sensitivity .............. ≤0.5% of measuring range to maximum input rangeInput Voltage ............................ 600V AC rms continuous (absolute maximum)
Overload Capacity 1.25 times the rated input Voltage continuously. 2 times the rated input Voltage for 10 secs. 4 times the rated input Voltage for 5 secs.
Input Current ............................ 3 times the rated input current continuously. Overload Capacity 10 times the rated input current for 10 secs. 50 times the rated input current for 1 sec. 80 times the rated input current for 0.5 secs
![Page 19: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/19.jpg)
Since 1976
(Z670)www.texmate.com 19
VAR Hours TRANSDUCERS
OUTPUT SPECIFICATIONSOutput Variables ................. PulsesRipple ................................... < 0.5% of rated output. Peak to Peak (maximum)Response Time ................... < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ................. ± 5% of rated output (minimum)Span Adjustment ................ ± 10% of rated output (minimum)
To calculate the actual VARHours for each output pulse, the CT and PT ratios have to be factored in
VARHours per Output Pulse = (CT Ratio) X (PT Ratio) Nominal Pulses /VARHour
Calculation example: For Single phase 2 wire, TQH-12If CT = 200A:5A then CT Ratio = 40 PT is 3300V:110V then PT Ratio = 30
If 1 pulse per VARHour is selected, the output will actually be 1 pulse per 1200 WARHoursIf 10 pulse per VARHour is selected, the output will actually be 1 pulse per 120 VARHoursIf 100 pulse per VARHour is selected, the output will actually be 1 pulse per 12 VARHours
CONNECTION DIAGRAM
OUTPUT+ +
ACPOWER230 V
115 V
L C.T.1
P2P1
1S 1L 3S 3L
P.T.1
N
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
OUTPUT+ +
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
N
L2
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TQH-12 TQH-13
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
L2
L3
OUTPUT+ +
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
ACPOWER230 V
115 V
L1C.T.1
P2 P3P1P0
1S 1L 2S 2L 3S 3L
C.T.3C.T.2
P.T.
2
P.T.
1
P.T.
3
L2
L3
N
OUTPUT+ +
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TQH-33 TQH-34
TQH
-12
1 Ph
ase,
1P/
2W, 1
E, V
ARh
ours
RO2
±0.2
5%SW
112
0V/5
A A
CH
Z660
Hz
OR1
Reed
Rel
ay.
P111
5/23
0 VA
C ±1
5%PU
51
puls
e pe
r VA
RHC
MM
etal
TQH
-13
1 Ph
ase,
1P/
3W, 2
E, V
ARh
ours
RO3
±0.1
%SW
224
0V/5
A A
CH
Z550
Hz
OR2
Reed
Rel
ay.
Forw
ard
+ Re
vers
eP2
24 V
DC
±15%
PU6
10 P
ulse
s Pe
r VA
RHC
PPl
astic
TQH
-33
3 Ph
ase,
3P/
3W, 2
E, V
ARh
ours
SWY
Cust
om In
put
HZ4
400H
zO
C1
Ope
n Co
llect
or.
Forw
ard
only
P312
5 VD
C ±1
5%PU
710
0 pu
lses
per
VA
RH
TQH
-34
3 Ph
ase,
3P/
4W, 3
E, V
ARh
ours
OC
2O
pen
Colle
ctor
. Fo
rwar
d +
Reve
rse
PYCu
stom
Pow
er ±
15%
PU8
1 pu
lse
per 1
000V
ARH
Aux
iliar
y Po
wer
Puls
e pe
r VA
RHou
rIn
put F
requ
ency
Base
Mod
el
Case
Inpu
t Sig
nal
Out
put S
igna
lA
ccur
acy
Forw
ard
only
TQH
![Page 20: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/20.jpg)
Since 1976
(Z670)www.texmate.com 20
MODELS OFFERED
FEATURES
TQQH-12: 1 Phase, 2 Wire – 1 ElementTQQH-13: 1 Phase, 3 Wire – 2 ElementTQQH-33: 3 Phase, 3 Wire – 2 ElementTQQH-34: 3 Phase, 4 Wire – 3 Element
• Uses Time Division Multiplication (TDM) for precision measurement of even distorted signals.• High accuracy ±0.2% of Rated Output (R.O.)• Super high accuracy ±0.1% of Rated Output (R.O.) available as a special order.*• High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277) or screw mounting.• Many input and output signal combinations.
VARs+VAR Hours TRANSDUCERS
• Accurate measurement of the reactive power and reactive energy (VARs and VARHours) of a three phase system with balanced or unbalanced loads.
• The output signals are isolated load independent pulses, repre-senting the measured value of the reactive energy (VARHours, forward and reverse) and DC mA or DC mV for the reactive power (VAR).
GENERAL SPECIFICATIONSAccuracy ................................... ± 0.2% R.O. Standard for 10 to 100% of rated output
± 0.1% R.O. (Special Option)Temp. coefficient ..................... ≤100ppm/ºC of span
≤60ppm/ºC for ambient temperature of 25ºC ±10ºCTemp. range .............................. Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF)
Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)Humidity range ........................ Up to 95% RH non condensingIsolation .................................... Between Input/Output/Power/CaseDielectric test ........................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ................................. DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ............. Greater than 100 M Ω at 500V DCHousing material ..................... ABS Resin(94V-0) or metalMounting ................................... Screw mount on metal case or Plastic case on DIN Rail 35mmAuxiliary Power ........................ AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional) 125V DC ± 20%(optional)
INPUT SPECIFICATIONSAC Input .................................... 120V/5A AC, 240V/5A AC. Custom input (600V max /10A AC max)Frequency ................................. 60Hz ±3Hz, 50Hz ±3Hz, 400Hz ±3Hz Burden ...................................... ≤0.2VA per current circuit, ≤0.1VA per voltage circuit.Response Sensitivity .............. ≤0.5% of measuring range to maximum input rangeInput Voltage ............................ 600V AC rms continuous (absolute maximum)
Overload Capacity 1.25 times the rated input Voltage continuously. 2 times the rated input Voltage for 10 secs. 4 times the rated input Voltage for 5 secs.
Input Current ............................ 3 times the rated input current continuously. Overload Capacity 10 times the rated input current for 10 secs. 50 times the rated input current for 1 sec. 80 times the rated input current for 0.5 secs
TQQH
![Page 21: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/21.jpg)
Since 1976
(Z670)www.texmate.com 21
Output Variables ................. Pulses (VARHours) and DC mA or DC V (VARs)Ripple ................................... < 0.5% of rated output. Peak to Peak (maximum)Response Time ................... < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ................. ± 5% of rated output (minimum)Span Adjustment ................ ± 10% of rated output (minimum)
To calculate the actual VARHours and VARs for each output pulse, the CT and PT ratios have to be factored in VARs = (CT Ratio) X (PT Ratio) x Nominal Watts
VARHours per Output Pulse = (CT Ratio) X (PT Ratio) Nominal Pulses /VARHour
Calculation example: For Single phase 2 wire, TQQH-12If CT = 200A:5A then CT Ratio = 40 PT is 3300V:110V then PT Ratio = 30
VARs = 30 x 40 x 500 = 600kVAR
If 1 pulse per VARHour is selected, the output will actually be 1 pulse per 1200 VARHoursIf 10 pulse per VARHour is selected, the output will actually be 1 pulse per 120 VARHoursIf 100 pulse per VARHour is selected, the output will actually be 1 pulse per 12 VARHours
VARs+VAR Hours TRANSDUCERS
OUTPUT SPECIFICATIONS
CONNECTION DIAGRAM
+ +
ACPOWER230 V
115 V
L C.T.1
P2P1
1S 1L 3S 3L
P.T.1
N
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
PULSEOUTPUT
+DC
OUTPUT
DCOUTPUT+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
PULSEOUTPUT
+ +
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
N
L2
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
+DC
OUTPUT
DCOUTPUT+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TQQH-12 TQQH-13
ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
L2
L3
PULSEOUTPUT
+ +
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
+DC
OUTPUT
DCOUTPUT
+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
ACPOWER230 V
115 V
L1C.T.1
P2 P3P1P0
1S 1L 2S 2L 3S 3L
C.T.3C.T.2
P.T.
2
P.T.
1
P.T.
3
L2
L3
N
PULSEOUTPUT
+ +
+ +FORW
ARD
PULS
E O
UTPU
T
REVE
RSE
+DC
OUTPUT
DCOUTPUT
+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TQQH-33 TQQH-34 TQQ
H-1
21
Phas
e, 1
P/2W
, 1E,
VA
R+VA
Rhou
rsRO
2±0
.25%
SW1
120V
/5A
AC
HZ6
60H
zO
QR4
VARs
±
1 m
A D
CVA
RHr
Reed
Rel
ay. F
orw
ard
only
P111
5/23
0 VA
C ±1
5%PU
51
puls
e pe
r VA
RHC
MM
etal
TQQ
H-1
31
Phas
e, 1
P/3W
, 2E,
VA
R+VA
Rhou
rsRO
3±0
.1%
SW2
240V
/5A
AC
HZ5
50H
zO
QR5
VARs
1
2±8m
A D
CVA
RHr
Reed
Rel
ay. F
orw
ard
and
Reve
rse
P224
VD
C ±1
5%PU
610
Pul
ses P
er V
ARH
CP
Plas
tic
TQQ
H-3
33
Phas
e, 3
P/3W
, 2E,
VA
R+VA
Rhou
rsSW
YCu
stom
Inpu
tH
Z440
0Hz
OQ
C4
VARs
±1m
A D
CVA
RHr
Ope
n Co
llect
or. F
orw
ard
only
P312
5 VD
C ±1
5%PU
710
0 pu
lses
per
VA
RH
TQQ
H-3
43
Phas
e, 3
P/4W
, 3E,
VA
Rs+V
ARh
ours
O
QC
5VA
Rs 1
2 ±
8mA
DC
VARH
r O
pen
Colle
ctor
. For
war
d +
Reve
rse
PYCu
stom
Pow
er ±
15%
PU8
1 pu
lse
per 1
000V
ARH
Base
Mod
el
Inpu
t Sig
nal
Out
put S
igna
lIn
put F
requ
ency
Acc
urac
yA
uxili
ary
Pow
erCa
sePu
lse
per V
ARH
our
TQQH
![Page 22: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/22.jpg)
Since 1976
(Z670)www.texmate.com 22
MODELS OFFERED
FEATURES
AC Power Factor TRANSDUCERS
• Uses Time Division Multiplication (TDM) for precision measurement of even distorted signals.• High accuracy ±0.5% of Rated Output (R.O.). • High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277) or screw mounting.• Many input and output signal combinations.
TPF-12: 1 Phase, 2 Wire – 1 ElementTPF-33: 3 Phase, 3 Wire – 2 ElementTPF-34: 3 Phase, 4 Wire – 3 Element
• Accurate measurement of the Power Factor (Cos φ) of a three phase system with balanced or unbalanced loads.
• The output signals are isolated load independent DC mA or DC V, representing the measured value of the Power Factor (Cos φ).
GENERAL SPECIFICATIONSAccuracy ................................... ± 0.2% R.O. Standard for 10 to 100% of rated output
± 0.1% R.O. (Special Option)Temp. coefficient ..................... ≤100ppm/ºC of span
≤60ppm/ºC for ambient temperature of 25ºC ±10ºCTemp. range .............................. Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF)
Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)Humidity range ........................ Up to 95% RH non condensingIsolation .................................... Between Input/Output/Power/CaseDielectric test ........................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ................................. DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ............. Greater than 100 M Ω at 500V DCHousing material ..................... ABS Resin(94V-0) or metalMounting ................................... Screw mount on metal case or Plastic case on DIN Rail 35mmAuxiliary Power ........................ AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional) 125V DC ± 20%(optional)
INPUT SPECIFICATIONSMeasuring Range ............... Power Factor
Lead (capacitive) 0.5 …. 1 …. Lag (Inductive) 0.5AC Voltage Input ................. 30 to 600VAC Current Input................. 0 to 5A ACFrequency ........................... 60Hz ±3Hz, 50Hz ±3Hz, 400Hz ±3Hz Burden ................................. ≤0.2VA per current circuit, ≤0.1VA per voltage circuit.Response Sensitivity ......... ≤0.5% of measuring range to maximum input rangeInput Voltage ...................... 600V AC rms continuous (absolute maximum)
Overload Capacity 1.25 times the rated input Voltage continuously. 2 times the rated input Voltage for 10 secs. 4 times the rated input Voltage for 5 secs.
Input Current ...................... 3 times the rated input current continuously. Overload Capacity 10 times the rated input current for 10 secs. 50 times the rated input current for 1 sec. 80 times the rated input current for 0.5 secs
TPF
![Page 23: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/23.jpg)
Since 1976
(Z670)www.texmate.com 23
AC Power Factor TRANSDUCERS
ACPOWER230 V
115 V
L1 C.T.1
P2P1
1S 1L 3S 3L
P.T.1
N
+DC
OUTPUT
DCOUTPUT
+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
Output Variables ................. DCmA or DCV (Power Factor. Cos φ)Ripple ................................... < 0.5% of rated output. Peak to Peak (maximum)Response Time ................... < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ................. ± 5% of rated output (minimum)Span Adjustment ................ ± 10% of rated output (minimum)
OUTPUT SPECIFICATIONS
CONNECTION DIAGRAM
TPF-12
TPF-33 TPF-34ACPOWER230 V
115 V
L1 C.T.1
P2 P3P1
1S 1L 3S 3L
C.T.3
P.T.1 P.T.3
L2
L3
PULSEOUTPUT
+ +
+ +FOR
WAR
D
PULS
E O
UTP
UT
REV
ERSE
+DC
OUTPUT
DCOUTPUT
+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
ACPOWER230 V
115 V
L1C.T.1
P2 P3P1P0
1S 1L 2S 2L 3S 3L
C.T.3C.T.2
P.T.
2
P.T.
1
P.T.
3
L2
L3
N
PULSEOUTPUT
+ +
+ +FOR
WAR
D
PULS
E O
UTP
UT
REV
ERSE
+DC
OUTPUT
DCOUTPUT
+
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
TPF-
121
Phas
e, 1
P/2W
, 1E,
Pow
er F
acto
rRO
6±0
.5%
SW1
120V
/5A
AC
HZ6
60H
zO
PF1
±1 m
A D
C,
0-1-
0 PF
LGLA
G =
+ P
olar
ityTP
F-33
3 Ph
ase,
3P/
3W, 2
E, P
ower
Fac
tor
RO5
±0.3
%SW
224
0V/5
A A
CH
Z550
Hz
OPF
24
to 2
0mA
DC
0-1
-0 P
FLD
LEA
D=
+Pol
arity
TPF-
343
Phas
e, 3
P/4W
, 3E,
Pow
er F
acto
rSW
YCu
stom
Inpu
tH
Z440
0Hz
OPF
A±1
mA
DC,
0
.5 -
1 - 0
.5 P
FO
PFB
4 to
20m
A D
C 0
.5 -
1 - 0
.5 P
F
Base
Mod
el
Aux
iliar
y Po
wer
Inpu
t Sig
nal
Inpu
t Fre
quen
cyA
ccur
acy
Out
put S
igna
lIn
put/
Out
put
Rela
tions
hip
CM
Met
alC
PPl
astic
Case
P1P011
5/23
0V A
C ±1
5%Si
ngle
Pow
ered
P224
V D
C ±1
5%
P312
5V D
C ±1
5%Cu
stom
Pow
er ±
15%
PY
TPF
![Page 24: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/24.jpg)
Since 1976
(Z670)www.texmate.com 24
MODELS OFFERED
FEATURES
FREQUENCY TRANSDUCERS
• High accuracy ±0.05% of Rated Output (R.O.). • Frequency range from 45 Hz to 10KHz. • High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277) or screw mounting.• Many input and output signal combinations.
TF-1: Frequency
GENERAL SPECIFICATIONS
Accuracy ............................. ± 0.2% R.O. Standard for 10 to 100% of rated output ± 0.1% R.O. (Special Option)
Temp. coefficient ................ ≤100ppm/ºC of span ≤60ppm/ºC for ambient temperature of 25ºC ±10ºC
Temp. range ........................ Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF) Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)
Humidity range ................... Up to 95% RH non condensingIsolation ............................... Between Input/Output/Power/CaseDielectric test ...................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ............................ DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ........ Greater than 100 M Ω at 500V DCHousing material ................ ABS Resin(94V-0) or metalMounting ............................. Screw mount on metal case or Plastic case on DIN Rail 35mmAuxiliary Power................... AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional) 125V DC ± 20%(optional)
TF
• Accurate measurement of the Frequency of a single or three phase system with balanced or unbalanced loads.
• The output signals are isolated load independent DC mA or DC V, representing the measured value of the Frequency.
![Page 25: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/25.jpg)
Since 1976
(Z670)www.texmate.com 25
+DC
OUTPUT
OUTPUT+ INPUT
+12V Auxiliary
Power for Sensor
ACPOWER230 V
115 V
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
Output Variables ................. DCmA or DCVRipple ................................... < 0.5% of rated output. Peak to Peak (maximum)Response Time ................... < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ................. ± 5% of rated output (minimum)Span Adjustment ................ ± 10% of rated output (minimum)Load Resistance ................. 10 kΩ maximum for 0 to 1mA output
500 Ω maximum for 4 to 20mA output 500 Ω minimum for 0 to 10V output
FREQUENCY TRANSDUCERS
OUTPUT SPECIFICATIONS
CONNECTION DIAGRAM
TF-1
1 Ph
ase,
1P/
2W,
Freq
uenc
yRO
7±0
.1%
SF1
80V
to 6
00V
AC
HZ2
45H
z to
55H
zO
HZ1
0 to
1 m
A D
CP1
115/
230
VAC
±15%
RO4
±0.0
5%SF
22V
to 3
0V A
C/D
CH
Z355
Hz
to 6
5Hz
OH
Z24
to 2
0mA
DC
P224
VD
C ±1
5%H
Z145
Hz
to 6
5Hz
OH
Z40±
1mA
DC
P312
5 VD
C ±1
5%H
ZYCu
stom
inpu
t Fq
rang
eO
HZY
Cust
om O
utpu
tPY
Cust
om P
ower
±15
%
Base
Mod
el
Inpu
t Sig
nal
Out
put S
igna
lA
uxili
ary
Pow
erIn
put F
requ
ency
Acc
urac
y
CM
Met
alC
PPl
astic
Case
TF
AC Voltage Input range ...... 2V to 200V AC or 30 to 600V ACFrequency ........................... 60Hz ±3Hz, 50Hz ±3Hz, 400Hz ±3Hz Burden ................................. ≤0.2VA per current circuit, ≤0.1VA per voltage circuit.Response Sensitivity ......... ≤0.5% of measuring range to maximum input rangeInput Voltage ....................... 600V AC rms continuous (absolute maximum)
Overload Capacity 1.25 times the rated input Voltage continuously. 2 times the rated input Voltage for 10 secs. 4 times the rated input Voltage for 5 secs.
INPUT SPECIFICATIONS
![Page 26: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/26.jpg)
Since 1976
(Z670)www.texmate.com 26
MODELS OFFERED
FEATURES
TD-1: DC Volts or mA
GENERAL SPECIFICATIONSAccuracy ............................. ± 0.1% R.O. Temp. coefficient ................ ≤100ppm/ºC of span
≤60ppm/ºC for ambient temperature of 25ºC ±10ºCTemp. range ........................ Storage temperature range -20ºC to 60ºC (-4ºF to 140ºF)
Operating temperature range 0ºC to 50ºC (32ºF to 122ºF)Humidity range ................... Up to 95% RH non condensingIsolation ............................... Between Input/Output/Power/CaseDielectric test ...................... DIN-IEC 688
2K Vrms/1 min, Between terminal to terminal 2.8K Vrms/1 min, Between terminal to case
Surge test ............................ DIN-IEC 255-4, ANSI C37 90a/1974 5KV(1.2x50 µs)Insulation Resistance ........ Greater than 100 M Ω at 500V DCHousing material ................ ABS Resin(94V-0) or metalMounting ............................. Screw mount on metal case or Plastic case on DIN Rail 35mmAuxiliary Power................... AC 115/230V ± 15%, 50/60Hz, 3VA
DC 24V ± 20%(optional) 125V DC ± 20%(optional)
DC Volts or mA TRANSMITTER ISOLATOR
• High accuracy ±0.2% of Rated Output (R.O.)• High immunity to external noise.• Quick and easy mounting to 35mm DIN Rail (DIN46277)• Many input and output signal combinations
TD
• The DC to DC Isolation Transmitter can receive various DC Voltage or Current signals and can output desired voltage or current signals isolated from each other
![Page 27: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/27.jpg)
Since 1976
(Z670)www.texmate.com 27
Output Variables ................. DC Voltage (0~10V) DC Current (0~20mA)
Response Time ................... < 400 milliseconds to go from 0 to 99% of outputZero Adjustment ................. ± 5% of rated output (minimum)Span Adjustment ................ ± 10% of rated output (minimum)
OUTPUT SPECIFICATIONS
CONNECTION DIAGRAM
TD
TD-1
DC
Volts
or m
ARO
7±0
.1%
SD1
0 to
1m
A D
CO
D1
0 to
1m
A D
CP1
115/
230
VAC
±15%
SD2
4 to
20m
A D
CO
D2
4 to
20m
A D
CP2
24 V
DC
±15%
SD
30
to 1
V D
CO
D3
0 to
10V
DC
P312
5 VD
C ±1
5%SD
40
to 1
0V D
CO
DYCu
stom
Out
put
PYCu
stom
Pow
er ±
15%
SDY
Cust
om In
put (
600V
max
)
Aux
iliar
y Po
wer
Base
Mod
el
Inpu
t Sig
nal
Acc
urac
yO
utpu
t Sig
nal
CM
Met
alC
PPl
astic
Case
1 2 3 4
5 6 7 8
OUTPUT INPUT
POWER
+
230 V115 V
OUTPUT+
INPUT+
Metal Case Plastic Din Rail
1 2 3 4
5 6 7 8
OUTPUT
INPUT
POWER
INPUT+
+
DC Voltage .......................... 0 to 600VDC Current .......................... for current input can be obtained from shunt
INPUT SPECIFICATIONS
DC Volts or mA TRANSMITTER ISOLATOR
![Page 28: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/28.jpg)
Since 1976
(Z670)www.texmate.com 28
CASE DIMENSIONS
Fire Retardant, ABS Case DIN Rail Mounting
4.32
” (1
07.5
mm
)
4.95
” (1
25.7
mm
)
0.6” (15.2mm)
1.38” (35mm) Rail (DIN 46277)
3.15” (80mm)
2.36
” (6
0mm
)
Case C
Metal Case, Screw Mounting4.
09"
(104
mm
)
4.84
" (1
23m
m)
1.
50"
(38.
1mm
)
2.2
8" (5
8mm
)
4.06" (103mm)
3.50" (89mm)
3.03" (77mm)
No.8-36UNFM4 Screw
Case A
450 State Place, Escondido, CA 92029 • For ordering info call: 1-800-TEXMATE (1-800-839-6283) or 760 598-9899• Email: [email protected] • 24 Hours • Fax: (760) 598-9828 •• For tech assistance call: (760) 598-9899
Copyright © 2016 Texmate Inc. All Rights Reserved.
CASE DIMENSIONS - CASE A & C
![Page 29: HIGH ACCURAC LEGENDAR RELIABILIT FAST DELIVERY … Transducer...TV-1 1 Phase, Avg se nsing Volts RO1 ±0.2% SV1 0 to 1 50 V AC HZ1 45 Hz to 65Hz OV1 0 to 1 mA DC CM Metal TV-1T 1 Phase,](https://reader033.vdocuments.us/reader033/viewer/2022052102/603ccc43ca82d54356432919/html5/thumbnails/29.jpg)
Since 1976
(Z670)www.texmate.com 29
CASE DIMENSIONS
Fire Retardant, ABS Case DIN Rail Mounting
Case BMetal Case, Screw Mounting
Case D
4.80" (122 mm)
0.748" (19 mm)
5.55
" (1
41m
m)
4.75" (120.65mm)
5.35" (136 mm)
4.33" (110 mm)
1.50"(38.1 m
m)
2.83" (72 mm
)
3.74" (95 mm
)
No.8-36UNFM4 Screw
3.74
” (9
5.0m
m)
4.45” (113.0mm)
5.02
” (1
27.5
mm
)
5.74
” (1
45.7
mm
)
0.6” (15.2mm)
1.38” (35mm) Rail (DIN 46277)
450 State Place, Escondido, CA 92029 • For ordering info call: 1-800-TEXMATE (1-800-839-6283) or 760 598-9899• Email: [email protected] • 24 Hours • Fax: (760) 598-9828 •• For tech assistance call: (760) 598-9899
Copyright © 2016 Texmate Inc. All Rights Reserved.
CASE DIMENSIONS - CASE B & D