hhhh o n o n r o t e tttt t c b electrical … drawings part... · fire alarm system j t ... ct...

28
3 4 P K DM M T a CTR GFI IG S S S S S S S S S K R G DM C B M T V F DH FS TS S H S S D SFD CM MM FACP FAA W M IC IC V S LC M OS J PB R TC MD DS DC C PC FB JUNCTION BOX PULLBOX - INTERIOR PULLBOX - EXTERIOR CIRCUIT BREAKER IN SINGLE ENCLOSURE RELAY TIME CLOCK MOTION DETECTOR DOOR SWITCH DOOR CONTACT CONTACTOR BUZZER PUSHBUTTON TRANSFORMER POWER METER PHOTOCELL HORN SOLENOID VALVE DISCONNECT SWITCH FUSED DISCONNECT SWITCH MOTOR CONTROLLER OR STARTER COMBINATION CONTROLLER/DISCONNECT SWITCH MOTOR LIGHTING CONTACTOR START/STOP SWITCH MOTOR CONTROLLER OR STARTER FURNISHED BY OTHERS CONDUIT CONDUIT BELOW FLOOR/ GRADE CONDUIT OR RACEWAY TURNED UP HOMERUN CONDUIT LONG STROKES INDICATE NEUTRAL CONDUCTOR SHORT STROKES INDICATE PHASE OR SWITCHED WIRES LONG STROKES WITH DOT INDICATES GROUNDING CONDUCTOR CAP-OFF CONDUIT OR RACEWAY TURNED DOWN TELEPHONE OUTLET WALL TELEPHONE OUTLET DATA OUTLET COMBINATION TELE/DATA OUTLET MICROPHONE OUTLET INTERCOM UNIT INTERCOM MASTER UNIT VOLUME CONTROL TELEVISION OUTLET TELEVISION CAMERA (CCTV) SPEAKER TELEPHONE TERMINAL CABINET TELEPHONE TERMINAL BACKBOARD SINGLE POLE SWITCH, 120/277V, 20A THREE-WAY SWITCH, 120/277V, 20A FOUR-WAY SWITCH, 120/277V, 20A SWITCH & PILOT LIGHT, 120/277V, 20A KEY OPERATED SWITCH, 120/277V, 20A DIMMER SWITCH, VOLTAGE AS NOTED THERMAL OVERLOAD SWITCH, VOLTAGE AS NOTED TIMER SWITCH, VOLTAGE AS NOTED LOWER CASE LETTER INDICATES SWITCHING ARRESTOR PLUS GROUND (SURGE ARRESTOR) CABLE TERMINATION (OVER 6OO VOLTS) CAPACITOR CIRCUIT BREAKER BREAKER WITH DRAWOUT FEATURE MV BREAKER WITH DRAWOUT FEATURE C ONTACT (NORMALLY OPEN) CONTACT (NORMALLY CLOSED) KIRK KEY INTERLOCK FUSE FUSED DISCONNECT SWITCH (UNDER 6OO VOLTS) SWITCH POWER TRANSFORMER CURRENT TRANSFORMER POTENTIAL TRANSFORMER DIGITAL METER PILOT LIGHT GENERATOR GROUND AUTOMATIC TRANSFER SWITCH SIMPLEX RECEPTACLE, 120V, 20A DOUBLE DUPLEX RECEPTACLE, (2) NEMA 5-20R SWITCHED DUPLEX RECEPTACLE, 120V, 20A SPECIAL PURPOSE OUTLET (TYPE AS NOTED) POWER COMMUNICATIONS POLE MULTIOUTLET ASSEMBLY DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER, NEMA 5-20R GFI RECEPTACLE, 120V, 20A ISOLATED GROUND (ORANGE) TYPE RECEPTACLE, 120V, 20A DUPLEX RECEPTACLE, NEMA 5-20R BELL FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR MANUAL FIRE ALARM PULL STATION FIRE ALARM HORN FIRE ALARM HORN AND STROBE FIRE ALARM BELL AND LIGHT FIRE ALARM STROBE DOOR HOLDER FLOW SWITCH TAMPER SWITCH SMOKE DETECTOR HEAT DETECTOR JUNCTION BOX FOR DUCT MOUNTED SELF CONTAINED 12O VOLT SMOKE DETECTOR SMOKE FIRE DAMPER CONTROL MODULE MONITOR MODULE SMOKE DETECTOR FLUORESCENT LIGHT FIXTURE CEILING FIXTURE WALL MOUNTED LIGHT FIXTURE FLUORESCENT STRIP LIGHT FIXTURE BOLLARD LIGHT TRACK LIGHT FLOOD LIGHT WALL WASHER, ARROW INDICATES AIM BATTERY PACK, NUMBER OF HEADS AS SHOWN EMERGENCY FIXTURE SWITCHED EMERGENCY CEILING FIXTURE POLE AND POLE MOUNTED LIGHT FIXTURES NUMBER OF HEADS AS SHOWN EXIT SIGN, SHADING INDICATES FACE, ARROWS AS INDICATED NL = NIGHT LIGHT (CONNECT TO UNSWITCHED LEG OF CIRCUIT) NL 3 SETS OF ONE AND ONE HALF INCH CONDUITS (3) 1- 1/2"C OCCUPANCY SENSOR FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE (PT DESIGNATES A POKE THROUGH DEVICE) FLOOR MOUNTED DUPLEX RECEPTACLE (PT DESIGNATES A POKE THROUGH DEVICE) FLOOR MOUNTED COMBO TELE/DATA OUTLET (PT DESIGNATES A POKE THROUGH DEVICE) FLOOR BOX - INTERIOR GENERAL ELECTRICAL LEGEND RACEWAYS COMMUNICATIONS SWITCHES SINGLE LINE DIAGRAM RECEPTACLES LIGHTING FIXTURES FIRE ALARM SYSTEM J T ABBREVIATIONS A,AMP AMPERE(S) AC ALTERNATING CURRENT AFF ABOVE FINISH FLOOR AFG ABOVE FINISHED GRADE AL ALUMINUM ALT ALTERNATE ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BC BARE COPPER BLDG BUILDING C CONDUIT CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CLG CEILING CT CURRENT TRANSFORMER CTR COUNTER CU COPPER CW COLD WATER DISC DISCONNECT DN DOWN DP DOUBLE POLE DT DOUBLE THROW DWG DRAWING (E) EXISTING TO REMAIN EC ELECTRICAL CONTRACTOR EA EACH EC EMPTY CONDUIT EIA ELECTRONIC INDUSTRIES ASSOCIATION ELEC ELECTRICAL OR ELECTRIC ELEV ELEVATOR EM EMERGENCY EMT ELECTRICAL METALLIC TUBING EOL END OF LINE RESISTOR EWC ELECTRICAL WATER COOLER F FUSE FAA FIRE ALARM REMOTE ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHERS FC FOOT CANDLE FLR FLOOR FT FOOT OR FEET GC GENERAL CONTRACTOR GEN GENERATOR GFI GROUND FAULT INTERRUPTER GND, G GROUND HID HIGH INTENSITY DISCHARGE HP HORSEPOWER HZ FREQUENCY CYCLES PER SECOND IC INTERCOM IG ISOLATED GROUND CONDUCTOR IMC INTERMEDIATE METALLIC CONDUIT IN INCH J-BOX JUNCTION BOX K KIRK KEY INTERLOCKED KCM THOUSAND CIRCULAR MIL(S) KV KILOVOLT KVA KILOVOLT AMPERE(S) KVAR KILOVAR(S) KW KILOWATT(S) KWHR KILOWATT HOUR MAX MAXIMUM MCC MOTOR CONTROL CENTER MH MANHOLE MIN MINIMUM MTD MOUNTED MTR MOTOR MTS MANUAL TRANSFER SWITCH N.C. NORMALLY CLOSED (D) DEMO, EXISTING TO BE REMOVED P CT EXTENT OF DEMOLITION FROM EXISTING POINT OF CONNECTION TO EXISTING H H H H T T T T B B B B ## # # # UNDERFLOOR DUCT (P=POWER, T=TEL, C=COMP) HEADER DUCT TRENCH DUCT BUS DUCT CABLE TRAY SHEET NOTE SYMBOL REVISION DELTA DETAIL CALLOUT TAG. # DESIGNATES DETAIL NUMBER, ## DESIGNATES SHEET ON WHICH DETAIL IS LOCATED BUS DUCT AND WIREWAY ANNOTATION TAGS AND NOMENCLATURE NOTE: NOT ALL SYMBOLS ARE USED ON THIS PROJECT. REFER TO ELECTRICAL SPECIFICATIONS FOR DEVICES MOUNTING HEIGHTS. DIMENSIONAL NUMBERS SHOWN ADJACENT TO SYMBOLS INDICATE THE CENTERLINE OF DEVICE MOUNTING HEIGHTS. PANELBOARD - SURFACE PANELBOARD - RECESSED SWITCHBOARD OR DISTRIBUTION BOARD QUANTITY OF SECTIONS REQUIRED SHOWN PANELS AND RELATED ITEMS DEVICE MOUNTING HEIGHTS ABBREVIATIONS CONTINUED N.C. NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NF NON FUSED N.O. NORMALLY OPEN # NUMBER NTS NOT TO SCALE NIC NOT IN CONTRACT OC ON CENTER OL OVERLOAD ELEMENT PB PUSH BUTTON PF POWER FACTOR PH, Ø PHASE PNL PANEL PT POTENTIAL TRANSFORMER PVC POLYVINYL CHLORIDE (R) EXISTING TO BE RELOCATED RMS ROOT MEAN SQUARE SHT SHEET SMR SURFACE METAL RACEWAY SP SINGLE POLE SPEC SPECIFICATIONS ST SINGLE THROW SW SWITCH SWBD SWITCHBOARD TEL TELEPHONE TEMP TEMPORARY TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION TSTAT THERMOSTAT TTB TELEPHONE TERMINAL BOARD TTC TELEPHONE TERMINAL CABINET TV TELEVISION TYP TYPICAL UG UNDERGROUND UH UNIT HEATER UPS UNINTERRUPTED POWER SUPPLY V VOLT(S) VA VOLT AMP(S) VAR REACTIVE VOLT AMPERES VP VAPOR PROOF W/ WITH W/O WITHOUT W WATT(S) WP WEATHERPROOF XFMR TRANSFORMER XP EXPLOSION PROOF LM S LOW VOLTAGE SWITCH, VOLTAGE AS NOTED HOA S HAND-OFF-AUTO SWITCH, 120/277V AS NOTED S CEILING FAN REMOTE HEAD EMERGENCY WALL MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE EMERGENCY WALL MOUNTED LIGHT FIXTURE EMERGENCY STRIP LIGHT FIXTURE CKD BY: SOLICITATION NO.: DATE: DRWN BY: LEE & SAKAHARA ARCHITECTURE PLANNING INTERIORS ARCHITECTS AIA 16842 Von Karman Ave., Suite 125, Irvine, CA 92606-4934 Tel. (949) 261-1100 Fax. (949) 261-1144 www.leesak.com DESIGNED BY: SHEET IDENTIFICATION 154 CONTRACT NO.: FILE NUMBER: PLOT DATE: PLOT SCALE: SUBMITTED BY: SIZE: FILE NAME: ANSI D 1 A SEAL AIR FORCE SERVICES ACTIVITY JBSA LACKLAND SAN ANTONIO, TEXAS F41999-14-F-1422 14508 B C D E F 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 7/14/2015 7:59:35 AM 12" = 1'-0" ELECTRICAL LEGEND, ABBREVIATION & SHEET INDEX GOLF CLUBHOUSE HILL AIR FORCE BASE, UTAH P. WHISENHUNT G. GOINS 10/13/14 E-001 M. ROSALES SHEET 127 OF 2 JULY 2015 G. GOINS GENERAL NOTES A. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND ORDINANCES. B. THESE DRAWINGS SHOW DESIGN INTENT ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE FIELD CONDITIONS WITH THE DRAWINGS AND WITH ALL OTHER TRADES. C. CONTRACTOR SHALL REVIEW ARCHITECTURAL, STRUCTURAL, MECHANICAL AND DRAWINGS FROM ALL OTHER DISCIPLINES PRIOR TO BID. D. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. E. PROVIDE SHOP DRAWING SUBMITTAL WITH 1/4" SCALE LAYOUT DRAWINGS OF ALL ROOMS WITH ELECTRICAL SWITCHGEAR AND TRANSFORMERS DRAWN TO SCALE. DRAWINGS SHALL SHOW LOCATIONS OF BOTH ELECTRICAL AND MECHANICAL EQUIPMENT. DEMONSTRATE COMPLIANCE WITH NEC 110.26 FOR WORKING CLEARANCES AROUND ELECTRICAL EQUIPMENT ON THESE DRAWINGS. F. ALL EXTERIOR MOUNTED ELECTRICAL DEVICES AND EQUIPMENT SHALL BE IN WEATHERPROOF ENCLOSURES AND U.L. LISTED FOR WET LOCATIONS. ELECTRICAL SHEET INDEX SUBMITTAL CODE OR REVISION DELTA # RTA SHEET NO. TITLE 2015-07-14 E-001 ELECTRICAL ABBREVIATIONS, LEGEND & SHEET INDEX ES-101 ELECTRICAL SITE PLAN E-101 ELECTRICAL LIGHTING PLAN E-102 ELECTRICAL POWER PLAN E-103 ELECTRICAL EQUIPMENT CONNECTION PLAN E-104 ELECTTRICAL ROOF PLAN E-401 ELECTRICAL ENLARGED PLAN E-600 ELECTRICAL SCHEDULES E-602 ELECTRICAL SCHEDULES E-603 LIGHTING IECC E-604 LIGHTING IECC E-604 LIGHTING IECC E-700 ELECTRICAL DIAGRAMS E-601 ELECTRICAL SCHEDULES MARK DESCRIPTION DATE APPR. P R O F E S S I O N A L E N G I N E E R - S T A T E O F N E V A D A P R O F E S S I O N A L E N G I N E E R - S T A T E O F N E V A D A ELECTRICAL WHISENHUNT PHILLIP A. JUN 30 2016 N o . 0 5 3 1 N o . 0 1 5 3 9 1 EXP. July 16, 2015

Upload: donhan

Post on 20-Aug-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

3

4

P

K

DM

M

T

a

CTR

GFI

IG

S

S

S

S

S

S

S

SS

K

R

G

DM

CB

M

TV

F

DH

FS

TS

S

H

S

S D

SFD

CM

MM

FACP

FAA

W

M

IC

IC

V

S

LC

M

OS

J

PB

RTC

MD

DS

DC

C

PC

FB

JUNCTION BOX

PULLBOX - INTERIOR

PULLBOX - EXTERIOR

CIRCUIT BREAKER IN SINGLE ENCLOSURE

RELAYTIME CLOCK

MOTION DETECTOR

DOOR SWITCHDOOR CONTACT

CONTACTOR

BUZZER

PUSHBUTTON

TRANSFORMER

POWER METER

PHOTOCELL

HORN

SOLENOID VALVEDISCONNECT SWITCH

FUSED DISCONNECT SWITCHMOTOR CONTROLLER OR STARTER

COMBINATION CONTROLLER/DISCONNECTSWITCH

MOTOR

LIGHTING CONTACTOR

START/STOP SWITCH

MOTOR CONTROLLER OR STARTERFURNISHED BY OTHERS

CONDUITCONDUIT BELOW FLOOR/ GRADECONDUIT OR RACEWAY TURNED UP

HOMERUN CONDUITLONG STROKES INDICATE NEUTRAL CONDUCTORSHORT STROKES INDICATE PHASE OR SWITCHEDWIRES LONG STROKES WITH DOT INDICATESGROUNDING CONDUCTOR

CAP-OFF

CONDUIT OR RACEWAY TURNED DOWN

TELEPHONE OUTLET

WALL TELEPHONE OUTLET

DATA OUTLET

COMBINATION TELE/DATA OUTLET

MICROPHONE OUTLET

INTERCOM UNIT

INTERCOM MASTER UNIT

VOLUME CONTROL

TELEVISION OUTLET

TELEVISION CAMERA (CCTV)

SPEAKER

TELEPHONE TERMINAL CABINET

TELEPHONE TERMINAL BACKBOARD

SINGLE POLE SWITCH, 120/277V, 20ATHREE-WAY SWITCH, 120/277V, 20A

FOUR-WAY SWITCH, 120/277V, 20A

SWITCH & PILOT LIGHT, 120/277V, 20A

KEY OPERATED SWITCH, 120/277V, 20ADIMMER SWITCH, VOLTAGE AS NOTEDTHERMAL OVERLOAD SWITCH, VOLTAGEAS NOTEDTIMER SWITCH, VOLTAGE AS NOTED

LOWER CASE LETTER INDICATES SWITCHING

ARRESTOR PLUS GROUND (SURGE ARRESTOR)

CABLE TERMINATION (OVER 6OO VOLTS)

CAPACITOR

CIRCUIT BREAKER

BREAKER WITH DRAWOUT FEATURE

MV BREAKER WITH DRAWOUT FEATURE

CONTACT (NORMALLY OPEN)

CONTACT (NORMALLY CLOSED)

KIRK KEY INTERLOCK

FUSEFUSED DISCONNECT SWITCH (UNDER 6OOVOLTS)SWITCH

POWER TRANSFORMER

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

DIGITAL METER

PILOT LIGHT

GENERATOR

GROUND

AUTOMATIC TRANSFER SWITCH

SIMPLEX RECEPTACLE, 120V, 20A

DOUBLE DUPLEX RECEPTACLE, (2) NEMA 5-20R

SWITCHED DUPLEX RECEPTACLE, 120V, 20A

SPECIAL PURPOSE OUTLET (TYPE AS NOTED)

POWER COMMUNICATIONS POLE

MULTIOUTLET ASSEMBLY

DUPLEX RECEPTACLE MOUNTEDABOVE COUNTER, NEMA 5-20R

GFI RECEPTACLE, 120V, 20A

ISOLATED GROUND (ORANGE) TYPERECEPTACLE, 120V, 20A

DUPLEX RECEPTACLE, NEMA 5-20R

BELL

FIRE ALARM CONTROL PANEL

FIRE ALARM ANNUNCIATOR

MANUAL FIRE ALARM PULL STATION

FIRE ALARM HORNFIRE ALARM HORN AND STROBEFIRE ALARM BELL AND LIGHT

FIRE ALARM STROBEDOOR HOLDER

FLOW SWITCH

TAMPER SWITCHSMOKE DETECTOR

HEAT DETECTOR

JUNCTION BOX FOR DUCT MOUNTED

SELF CONTAINED 12O VOLT SMOKE DETECTOR

SMOKE FIRE DAMPER

CONTROL MODULE

MONITOR MODULE

SMOKE DETECTOR

FLUORESCENT LIGHT FIXTURE

CEILING FIXTURE

WALL MOUNTED LIGHT FIXTURE

FLUORESCENT STRIP LIGHT FIXTURE

BOLLARD LIGHT

TRACK LIGHT

FLOOD LIGHT

WALL WASHER, ARROW INDICATES AIM

BATTERY PACK, NUMBER OF HEADS AS SHOWN

EMERGENCY FIXTURE SWITCHED

EMERGENCY CEILING FIXTURE

POLE AND POLE MOUNTED LIGHT FIXTURESNUMBER OF HEADS AS SHOWN

EXIT SIGN, SHADING INDICATESFACE, ARROWS AS INDICATED

NL = NIGHT LIGHT (CONNECT TO UNSWITCHEDLEG OF CIRCUIT)

NL

3 SETS OF ONE AND ONE HALF INCHCONDUITS

(3) 1-1/2"C

OCCUPANCY SENSOR

FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE(PT DESIGNATES A POKE THROUGH DEVICE)

FLOOR MOUNTED DUPLEX RECEPTACLE(PT DESIGNATES A POKE THROUGH DEVICE)

FLOOR MOUNTED COMBO TELE/DATA OUTLET(PT DESIGNATES A POKE THROUGH DEVICE)

FLOOR BOX - INTERIOR

GENERAL

ELECTRICAL LEGEND

RACEWAYS

COMMUNICATIONS

SWITCHES

SINGLE LINE DIAGRAMRECEPTACLES

LIGHTING FIXTURES

FIRE ALARM SYSTEM

J

T

ABBREVIATIONS

A,AMP AMPERE(S)AC ALTERNATING CURRENTAFF ABOVE FINISH FLOORAFG ABOVE FINISHED GRADEAL ALUMINUMALT ALTERNATEATS AUTOMATIC TRANSFER SWITCHAWG AMERICAN WIRE GAUGE

BC BARE COPPERBLDG BUILDING

C CONDUITCB CIRCUIT BREAKERCCTV CLOSED CIRCUIT TELEVISIONCKT CIRCUITCLG CEILINGCT CURRENT TRANSFORMERCTR COUNTERCU COPPERCW COLD WATER

DISC DISCONNECTDN DOWNDP DOUBLE POLEDT DOUBLE THROWDWG DRAWING

(E) EXISTING TO REMAINEC ELECTRICAL CONTRACTOREA EACHEC EMPTY CONDUITEIA ELECTRONIC INDUSTRIES ASSOCIATIONELEC ELECTRICAL OR ELECTRICELEV ELEVATOREM EMERGENCYEMT ELECTRICAL METALLIC TUBINGEOL END OF LINE RESISTOREWC ELECTRICAL WATER COOLER

F FUSEFAA FIRE ALARM REMOTE ANNUNCIATOR PANELFACP FIRE ALARM CONTROL PANELFBO FURNISHED BY OTHERSFC FOOT CANDLEFLR FLOORFT FOOT OR FEET

GC GENERAL CONTRACTORGEN GENERATORGFI GROUND FAULT INTERRUPTERGND, G GROUND

HID HIGH INTENSITY DISCHARGEHP HORSEPOWERHZ FREQUENCY CYCLES PER SECOND

IC INTERCOMIG ISOLATED GROUND CONDUCTORIMC INTERMEDIATE METALLIC CONDUITIN INCH

J-BOX JUNCTION BOX

K KIRK KEY INTERLOCKEDKCM THOUSAND CIRCULAR MIL(S)KV KILOVOLTKVA KILOVOLT AMPERE(S)KVAR KILOVAR(S)KW KILOWATT(S)KWHR KILOWATT HOUR

MAX MAXIMUMMCC MOTOR CONTROL CENTERMH MANHOLEMIN MINIMUMMTD MOUNTEDMTR MOTORMTS MANUAL TRANSFER SWITCH

N.C. NORMALLY CLOSED

(D) DEMO, EXISTING TO BE REMOVED

P

CT

EXTENT OF DEMOLITION FROM EXISTING

POINT OF CONNECTION TO EXISTING

H H H H

T T T T

B B B B

##

#

#

#

UNDERFLOOR DUCT (P=POWER, T=TEL, C=COMP)

HEADER DUCT

TRENCH DUCT

BUS DUCT

CABLE TRAY

SHEET NOTE SYMBOL

REVISION DELTA

DETAIL CALLOUT TAG. # DESIGNATESDETAIL NUMBER, ## DESIGNATES SHEETON WHICH DETAIL IS LOCATED

BUS DUCT AND WIREWAY

ANNOTATION TAGS AND NOMENCLATURE

NOTE: NOT ALL SYMBOLS ARE USED ON THIS PROJECT.

REFER TO ELECTRICAL SPECIFICATIONS FORDEVICES MOUNTING HEIGHTS. DIMENSIONALNUMBERS SHOWN ADJACENT TO SYMBOLSINDICATE THE CENTERLINE OF DEVICEMOUNTING HEIGHTS.

PANELBOARD - SURFACE

PANELBOARD - RECESSED

SWITCHBOARD OR DISTRIBUTION BOARDQUANTITY OF SECTIONS REQUIRED SHOWN

PANELS AND RELATED ITEMS

DEVICE MOUNTING HEIGHTS

ABBREVIATIONS CONTINUED

N.C. NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODENF NON FUSEDN.O. NORMALLY OPEN

# NUMBERNTS NOT TO SCALENIC NOT IN CONTRACT

OC ON CENTEROL OVERLOAD ELEMENT

PB PUSH BUTTONPF POWER FACTORPH, Ø PHASEPNL PANELPT POTENTIAL TRANSFORMERPVC POLYVINYL CHLORIDE

(R) EXISTING TO BE RELOCATEDRMS ROOT MEAN SQUARE

SHT SHEETSMR SURFACE METAL RACEWAYSP SINGLE POLESPEC SPECIFICATIONSST SINGLE THROWSW SWITCHSWBD SWITCHBOARD

TEL TELEPHONETEMP TEMPORARYTIA TELECOMMUNICATIONS INDUSTRY ASSOCIATIONTSTAT THERMOSTATTTB TELEPHONE TERMINAL BOARDTTC TELEPHONE TERMINAL CABINETTV TELEVISIONTYP TYPICAL

UG UNDERGROUNDUH UNIT HEATERUPS UNINTERRUPTED POWER SUPPLY

V VOLT(S)VA VOLT AMP(S)VAR REACTIVE VOLT AMPERESVP VAPOR PROOF

W/ WITHW/O WITHOUTW WATT(S)WP WEATHERPROOF

XFMR TRANSFORMERXP EXPLOSION PROOF

LMS LOW VOLTAGE SWITCH, VOLTAGE AS NOTEDHOAS HAND-OFF-AUTO SWITCH, 120/277V AS NOTED

S

CEILING FAN

REMOTE HEAD

EMERGENCY WALL MOUNTED LIGHT FIXTURE

WALL MOUNTED LIGHT FIXTURE

EMERGENCY WALL MOUNTED LIGHT FIXTURE

EMERGENCY STRIP LIGHT FIXTURE

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 7:

59:3

5 AM

12" =

1'-0"

ELEC

TRIC

AL L

EGEN

D, A

BBRE

VIAT

ION

& SH

EET

INDE

X

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

10/13

/14

E-001

M. R

OSAL

ES

SHEET 127 OF

2 JUL

Y 20

15G.

GO I

NS

GENERAL NOTES

A. WORK, MATERIALS, AND EQUIPMENT SHALLCONFORM TO THE LATEST EDITIONS OFLOCAL, STATE, AND NATIONAL CODES ANDORDINANCES.

B. THESE DRAWINGS SHOW DESIGN INTENTONLY. IT IS THE RESPONSIBILITY OF THECONTRACTOR TO COORDINATE FIELDCONDITIONS WITH THE DRAWINGS AND WITHALL OTHER TRADES.

C. CONTRACTOR SHALL REVIEWARCHITECTURAL, STRUCTURAL, MECHANICALAND DRAWINGS FROM ALL OTHERDISCIPLINES PRIOR TO BID.

D. DO NOT SCALE DRAWINGS. VERIFYDIMENSIONS IN FIELD PRIOR TOCOMMENCEMENT OF WORK.

E. PROVIDE SHOP DRAWING SUBMITTAL WITH1/4" SCALE LAYOUT DRAWINGS OF ALLROOMS WITH ELECTRICAL SWITCHGEAR ANDTRANSFORMERS DRAWN TO SCALE.DRAWINGS SHALL SHOW LOCATIONS OFBOTH ELECTRICAL AND MECHANICALEQUIPMENT. DEMONSTRATE COMPLIANCEWITH NEC 110.26 FOR WORKINGCLEARANCES AROUND ELECTRICALEQUIPMENT ON THESE DRAWINGS.

F. ALL EXTERIOR MOUNTED ELECTRICALDEVICES AND EQUIPMENT SHALL BE INWEATHERPROOF ENCLOSURES AND U.L.LISTED FOR WET LOCATIONS.

ELECTRICAL SHEET INDEXSUBMITTAL CODE OR REVISION DELTA # RTA

SHEET NO. TITLE 2015-07-14

E-001 ELECTRICAL ABBREVIATIONS, LEGEND & SHEET INDEX

ES-101 ELECTRICAL SITE PLAN

E-101 ELECTRICAL LIGHTING PLAN

E-102 ELECTRICAL POWER PLAN

E-103 ELECTRICAL EQUIPMENT CONNECTION PLAN

E-104 ELECTTRICAL ROOF PLAN

E-401 ELECTRICAL ENLARGED PLAN

E-600 ELECTRICAL SCHEDULES

E-602 ELECTRICAL SCHEDULES

E-603 LIGHTING IECC

E-604 LIGHTING IECC

E-604 LIGHTING IECC

E-700 ELECTRICAL DIAGRAMS

E-601 ELECTRICAL SCHEDULES

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

RETAINING WALL

(E) RETAINING WALL

EXISTINGGOLF CARTS

EXISTING LOWER LEVEL PARKING

EXISTING UPPER LEVEL PARKING

PRACTICEGREEN

#9 HOLE

#18 HOLE

#10 TEE

#1 TEE

DRIVING RANGE

CARTSTAGING

CART STAGING

SLOPEWALK

STEPSDN

EXISTINGCLUBHOUSE

(E) CART PATHRAMP

DELIVERY

ACCESSIBLEPARKING

ENTRY

FIRE TRUCKACCESS

LANDSCAPE

TRANSFORMER

BAG DROP

DROP OFF

ENTRYWALKWAY

VISUALLANDSCAPESCREEN

T

FLUSHPULLBOX

'MSA'

NEWPULLBOX

NEWINTERCEPTBOX

EXIST.PRIMARYTRENCH

H

H

H

1 2

3

4

5

#4

6MSA-4

B-1#10

7

HEIGHT

8'-0"

POLE

40'-0"30'-0"20'-0"

12'-0"

2"X4" HANDHOLEWITH COVER

MANUFACTURER

BASE PLATE AND

THE PIERWITHIN TOP 5" OF

12"

GROUND LUG

MAXIMUM

(6) #4 VERTICAL

24"

DEPTHFOOTING

6'-0"5'-0"4'-0"3'-0"2'-6"

DEPTH

#3 TIES @ 12" O.C.

(3) #3 OR (2) #4 TIES

ANCHOR BOLTS BY

WITH #8 AWG CuGROUND LUG

TO REBAR IN FOOTING

CONCRETE f'c=4,500 PSI

FINISHGRADE

5"

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 8:

00:0

6 AM

As in

d icate

dEL

ECTR

ICAL

SIT

E PL

AN

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

10/13

/14

ES-101

M. R

OSAL

ES

SHEET 128 OF

2 JUL

Y 20

15G.

GO I

NS

SCALE: 1" = 40'-0"1 ELECTRICAL SITE PLAN

NOTES

1 NEW PAD MOUNTED LOOP FEEDTRANSFORMER. RE: 1/E-700.

2 EXISTING PAD MOUNTED TRANSFORMER TOBE RECONNECTED FROM THE NEWTRANSFORMER. RE: 1/E-700.

3 EXISTING DISTRIBUTION FROM THE EXISTINGTRANSFORMER TO REMAIN.

4 INSTALL PULLBOX 3'X4'X4' PULLBOX FLUSHWITH GRADE AS A WATER BREAK ONSECONDARY CONDUITS.

5 INTERCEPT BOX DRAIN TO DAYLIGHT.

6 MAKE FINAL CONNECTION TO LIFT STATIONCONTROL PANEL.

7 ROUTE THROUGH PHOTO-CELL. RE: E-101.

' '

GENERAL NOTES

A. LOCATION OF EQUIPMENT IS DIAGRAMATIC.VERIFY IN FIELD ACTUAL LOCATIONS.

B. POWER FEEDER CONNECTION WILL REQUIRESHUTDOWN. DO NOT PROCEDE WITHOUTAUTHORIZATION.

C. REFER TO SHEET E-500 FOR LIGHTINGFIXTURE SCHEDULE.

SCALE: 12" = 1'-0"2 BOLTED LIGHT POLE BASE DETAIL

N

PLANNORTH

0'

SCALE : 1" = 40'-0"

20' 40' 80'

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

SS

S

S

S

SS

SS

SS

S

S

S

S

MOS MOS

MOS

MOS

MOS

MOS

S S SS MOS

S MOS

MOS

SS

S

S

SS

S

S

S

SS

S

S

S

S

S

PC

J

S

S

S

'A' 'B'

'K'

BB

B1

B

B1

A3

A3

A4

A3A3

A3 A4

A3 A3

A3 A4

A3 A4

A3 A3

A3 A4

A3 A3

A4A3

A3 A3

A4A3

B1 B B1

F F1 F1 F

F1

F F1

X

X

X

X X X

X X

X

X

X

XX

OS

'LCP'

'MSA'

OSOS

D D

DD

DDG

G

G

G

C

C C

DINING19

MAINDINING

20

B1

A4

A3

A4

A3

A3 A4 A3 A3 A3

A4

A4A3

A3A3

A3

B1

A1A

A A

A4

A3

A4 A3 A4

A3A3

A3 A4

A4

B3 B2 B3

B3B2 B2F

BB3

B2 B3

B2

A3

A3 A2A2

FB

B

A3 A3 A3 A3

A3

A4

A3

A1

A4 A3 A4 A3 A4

A

A

A1

A

A A1 A1 A

A A1 A A1 A

A A

A A A A

A

A

A1

A1AA1AA1A

A1

A A

A

A

A

A1

A

A

AA A

A

A A

A1

A A

A1

A

A

A1

A

A1

A

A

A

A

A

A1

A A

A

A

A1 A A1

AA

A A1

A A A

A

A

A1A

A

AA

AA1 A1 A A1A A1 A A1 A A1

A A1 A A1 A A1

A1 A A1 A A1 A

A1AA1AA1A

A1 A A1 A A1

A

A

OS

OS

OS

OS OS OSOS

B B

B

A3

A3

F

K1 K K K K1

KKK1KK

K1 K K K K1

A

A1 A1 A

A

A

A1

A1

VESTIBULE01

ASSISTANTGM16

STORAGE46

POCKETCLOSET

24

FUNCTIONROOM

STORAGE28

COVEREDTERRACE

51

STORAGE15

VESTIBULE05

ENTRYPORCH

50

W.I.C.42

CO237

STAGING26

HALL12

HALLWAY04

COOKLINE38

CATERING33

FREEZER43

ICE34

CONCOURSE03

ELEC'LROOM

30 COMM29

PRO SHOP18

MEN'SLOCKERROOM

09ADMIN.

11

COVEREDTERRACE

53

COVEREDTERRACE

54

CLOSET13

GENERALMANAGER

14

TOILET35

COVEREDTERRACE

52

FUNCTIONROOM

25

DINING19

MECH'LROOM

31

FUNCTIONPREP

32

LOBBY02

PREP41

DISHWASH40

JANITOR45

DRYSTORAGE

44

LADIESLOCKERROOM

06

JAN / ROOFACCESS

10

SERVICEYARD

56

SERVICECOUNTER

22

PREP39

COVEREDTERRACE

55

G

G

G

G

A-17

GG

A-21

A-19

A-4

A-8

OS

A-6

DD

A-13

D

D

A-11

A-9

A-7

D D

OS

3

3

A-23

DD

OR

A-1

A-15

A-3

G G

G G G

OR

OR

A-5

+96"

A-2

B-1

A A

B B

E

G

F F

D

1

1 4

8

8

72

6

3 5

C

2

'LCP'

LTG CIRCUITS

OR

OR

OR

(3) OVERRIDESWITCH LOCATIONS

LIGHTING CONTROL PANELWATTSTOPPER LP8 OR EQUAL

INDIVIDUAL CIRCUITS IN

CIRCUITS: A-1,3,5,7,9,11,13,15,17,19TO BE TIMECLOCK CONTROLLED

CIRCUITS: A-21,23TO BE PHOTOCELL CONTROLLED

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 7:

59:4

0 AM

As in

d icate

dEL

ECTR

ICAL

LIG

HTIN

G PL

AN

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

10/13

/14

E-101

M. R

OSAL

ES

SHEET 129 OF

2 JUL

Y 20

15G.

GO I

NS

SCALE: 1/8" = 1'-0"1 ELECTRICAL LIGHTING PLAN

GENERAL NOTES

A. REFER TO ARCHITECTURAL REFLECTEDCEILING PLANS, SECTIONS, ELEVATIONS,ETC. FOR EXACT LOCATION OF LIGHTINGFIXTURES.

B. PROVIDE AN UNSWITCHED CIRCUITCONDUCTOR TO EXIT SIGNS, NIGHT LIGHTS'NL', AND EMERGENCY LIGHTS.

C. WHERE MULTIPLE LIGHT SWITCHES AREINDICATED AT A SINGLE LOCATION, MOUNTSWITCHES UNDER COMMON GANGEDFACEPLATE. MULTIPLE SINGLE GANGFACEPLATES ARE NOT ACCEPTABLE.

D. REFER TO SHEET E-600 FOR LIGHTINGFIXTURE SCHEDULE.

NOTES

1 TO SITE LIGHING. RE: ES-101.

2 MOUNT EXIT SIGN IN VIEW OF KITCHENCORRIDOR.

' '

SCALE: 12" = 1'-0"2 LCP DETAIL

N

PLANNORTH

0'

SCALE : 1/8" = 1'-0"

4' 8' 16'

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

TV

TV

TV

TV

TVGFIWP

E-4011

GFIWP

GFIWP

GFIWP

GFIWP

GFIWP

GFIWP

GFIWP

GFIWP

GFIWP

GFIWP

GFI

'A' 'B'

'K'

+48" +48" +48" +48"

+48"GFI

+48"GFI

+48"GFI

+48"GFI+48"GFI

CLG

CLG

'LCP'

'MSA'

1

1

2

3

GFI

E-4012

WH-1

CP-1

J

1

+96"

+96"

+96"

+96"

+96"

+96"

DINING19

MAINDINING

20

+96"

+96"

+96"

+96"

+96"+96"+96"+96"

VESTIBULE01

ASSISTANTGM16

STORAGE46

POCKETCLOSET

24

FUNCTIONROOM

STORAGE28

COVEREDTERRACE

51

STORAGE15

VESTIBULE05

ENTRYPORCH

50

W.I.C.42

CO237

STAGING26

HALL12

HALLWAY04

COOKLINE38

CATERING33

FREEZER43

ICE34

CONCOURSE03

ELEC'LROOM

30 COMM29

PRO SHOP18

MEN'SLOCKERROOM

09

ADMIN.11

CAN WASH27

COVEREDTERRACE

53COVEREDTERRACE

54

CLOSET13

GENERALMANAGER

14

TOILET35

COVEREDTERRACE

52

FUNCTIONROOM

25

DINING19

MECH'LROOM

31

FUNCTIONPREP

32

LOBBY02

PREP41DISHWASH

40

JANITOR45

DRYSTORAGE

44

LADIESLOCKERROOM

06

JAN / ROOFACCESS

10

SERVICEYARD

56

SERVICECOUNTER

22

PREP39

COVEREDTERRACE

55

GFIWP

A-34

A-16

A-14

A-20

A-22A-27

A-36

A-38

A-48

A-43 A-41

GFI

A-44A-46

A-39

A-37A-35

A-33

A-31

A-42

A-25 A-40

A-29

A-454

5

6

K-47 K-45

K-43

J

B-15

7

A A

B B

E

G

F F

D

1

1 4

8

8

72

6

3 5

C

A-18

+96"

8

E-4014

J

A-32A-109

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 7:

59:4

5 AM

1/8"

= 1'-0

"EL

ECTR

ICAL

POW

ER P

LAN

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

10/13

/14

E-102

M. R

OSAL

ES

SHEET 130 OF

2 JUL

Y 20

15G.

GO I

NS

SCALE: 1/8" = 1'-0"1 ELECTRICAL POWER PLAN

NOTES

1 RECEPTACLE ABOVE CEILING FOR POSSIBLESHOW WINDOW EQUIPMENT.

2 (2) 4"C FOR COMMUNICATIONS REFER TOSITE PLAN SHEET ES-101.

3 INCOMING ELECTRICAL SERVICE. REFER TOSITE PLAN SHEET ES-101.

4 1"C WITH (3)CAT. 6 TO CER.

5 1"C, (3) CAT. 6 TO CER. TYPICAL ALLTELEPHONE/DATA LOCATION.

6 3/4"C WITH (1) RG6 COAX TO CER FORTV SERVICE. TYPICAL.

7 J-BOX FOR GREASE LINE HEAT TRACE.

8 (2) 4" PVC SCH. 40 WITH PULLSTRINGS TOTRANSFORMER. RE: SINGLE LINE.

9 J-BOX FOR STORM DRAIN HEAT TRACE.+48" AFF.

' '

GENERAL NOTES

A. REFER TO EQUIPMENT CONNECTIONSCHEDULE ON SHEET E-600 FORADDITIONAL INFORMATION ANDREQUIREMENTS. PROVIDE COMPLETEELECTRICAL CONNECTION TO ALLEQUIPMENT REQUIRING POWER UNLESSNOTED OTHERWISE.

B. COORDINATE EXACT MECHANICAL EQUIPMENTLOCATIONS AND REQUIREMENTS WITHMECHANICAL CONTRACTOR PRIOR TOROUGH-IN.

N

PLANNORTH

0'

SCALE : 1/8" = 1'-0"

4' 8' 16'

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

J

J

J

S

J

'A' 'B'

'K'

'LCP'

'MSA'

WH-1CP-1

DINING19

MAINDINING

20

VESTIBULE01

ASSISTANTGM16

STORAGE46

POCKETCLOSET

24

FUNCTIONROOM

STORAGE28

COVEREDTERRACE

51

STORAGE15

VESTIBULE05

ENTRYPORCH

50

W.I.C.42

CO237

STAGING26

HALL12

HALLWAY04

COOKLINE38

CATERING33

FREEZER43

ICE34

CONCOURSE03

ELEC'LROOM

30

COMM29

PRO SHOP18

MEN'SLOCKERROOM

09

ADMIN.11

CAN WASH27

COVEREDTERRACE

53COVEREDTERRACE

54

CLOSET13

GENERALMANAGER

14

TOILET35

COVEREDTERRACE

52

FUNCTIONROOM

25

DINING19

MECH'LROOM

31

FUNCTIONPREP

32

LOBBY02

PREP41DISHWASH

40

JANITOR45

DRYSTORAGE

44

LADIESLOCKERROOM

06

JAN / ROOFACCESS

10

SERVICEYARD

56

SERVICECOUNTER

22

PREP39

COVEREDTERRACE

55

FC-8 FC-9

ACI-2

ACI-1

FC-2 FC-4

FC-3

FC-1

FC-5

FC-7

FC-6

B-22,24

B-26,28

B-18,20

B-14,16

B-10,12

B-6,8

B-2,4

B-7,9

B-11

1

2

2

2

2

2

2

2

2

2

B-30,32

A A

B B

E

G

F F

D

1

1 4

8

8

72

6

3 5

C

B-3,5

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 7:

59:5

1 AM

1/8"

= 1'-0

"EL

ECTR

ICAL

EQU

IPM

ENT

CONN

ECTI

ON P

LAN

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

04/01

/15

E-103

M. R

OSAL

ES

SHEET 131 OF

2 JUL

Y 20

15G.

GO I

NS

SCALE: 1/8" = 1'-0"1 ELECTRICAL EQUIPMENT CONNECTION PLAN

NOTES

1 3/4"C 3#12 TO FAN COIL.

2 NEUTRAL MAY BE REQUIRED IF ECMMOTORS ARE USED.

' '

GENERAL NOTES

A. REFER TO EQUIPMENT CONNECTIONSCHEDULE ON SHEET E-600 FORADDITIONAL INFORMATION ANDREQUIREMENTS. PROVIDE COMPLETEELECTRICAL CONNECTION TO ALLEQUIPMENT REQUIRING POWER UNLESSNOTED OTHERWISE.

B. COORDINATE EXACT MECHANICAL EQUIPMENTLOCATIONS AND REQUIREMENTS WITHMECHANICAL CONTRACTOR PRIOR TOROUGH-IN.

BC-1.1

BC-1.2

N

PLANNORTH

0'

SCALE : 1/8" = 1'-0"

4' 8' 16'

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

CU-1

KEF-1

MAU-1

RTU-1

ERV-1

MSA-5

MSA-6

MSA-9MSA-7

MSA-8

GFIWP

GFIWP

GFIWP

B-131

A A

B B

E

G

F F

D

1

1 4 8

72

6

3 5

C

2

2

2

2

2

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 4:

06:4

7 PM

1/8"

= 1'-0

"EL

ECTR

ICAL

ROO

F PL

AN

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

10/13

/14

E-104

M. R

OSAL

ES

SHEET 132 OF

2 JUL

Y 20

15G.

GO I

NS

SCALE: 1/8" = 1'-0"1 ELECTRICAL ROOF PLAN

NOTES

1 1"C DOWN TO HOOD CONTROLS. REFER TOHOOD SHOP DRAWINGS FOR CONDUCTORSREQUIRED.

2 ROUTE CONDUIT DOWN ROOF CURB TOLIMIT PENETRATIONS.

' '

GENERAL NOTES

A. REFER TO EQUIPMENT CONNECTIONSCHEDULE ON SHEET E-600 FORADDITIONAL INFORMATION ANDREQUIREMENTS. PROVIDE COMPLETEELECTRICAL CONNECTION TO ALLEQUIPMENT REQUIRING POWER UNLESSNOTED OTHERWISE.

B. COORDINATE EXACT MECHANICAL EQUIPMENTLOCATIONS AND REQUIREMENTS WITHMECHANICAL CONTRACTOR PRIOR TOROUGH-IN.

N

PLANNORTH

0'

SCALE : 1/8" = 1'-0"

4' 8' 16'

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

2154

K

2148

1860

1860

1842

1860

1860

2136

J

J

J

J

J

J

J

F

G

J

73

64 726771

62 54

GFICTR

561

1

51 44

J

24

41

42

35

74

ROOF

30

+12"

53

+12"

54

+12"

52

+12"

47

+12"

46

+12"

17

36

K-26,28

K-30,32

K-24

K-22

K-20

CTR

K-1

GFI

K-23

CTR

K-3

CTR

CTR

K-5

+12"CTR

K-7 K-9

67 65

K-25,27,29

60A

#8

K-18LTS

LTS

LTS

+12"

66

K-11

K-6K-8 K-10

+48"

K-12

K-16

+48"

K-35

K-14

K-21

27

GFICTR

27K-33

K-4

GFICTR

62

GFICTR

K-31 K-2

2

3

3

+12"

70

K-13

+12"

69

K-15

CTR

K-17 K-19

FREEZER 30A

K-37,39,41

30A3P 74

COOLER

K-34,36

E

F

4

5

CTRCTR

K-51

K-49

+96"

+96"

J

J

GFICTR

GFICTR

GFICTR

GFICTR

GFICTR

6

13

1

GFICTR

FUNCTIONPREP

32

K-46

K-44K-42

K-38,40

F

4

ST JGAS

SOLENOIDANSULSYSTEM

H NK-2

STSTSTSTSTST

G

6

COMM29

(1) 4"CA-30A-28

GROUND BUS#1, CU, 1"CTO MAINSWITCHBOARDGROUND BUS

CLG

CLG

CLG

A-47,49

L6-20R

A-26

14" WIREBASKET TRAY

A-24

WITH PIGTAILCADWELD CONNECTION

COPPER BAR

2700 VOLT INSULATORS

STAND-OFFS

SECURELY ATTACHTO THE WALL

1. ALL COMMUNICATION WORK SHALL COMPLY TO THE 75 ABW/SCCOMMUNICATIONS & INFORMATION DIRECTORATE HILL AFB, UTAHTELECOMMUNICATIONS INSTALLATION CRITERIA FOR FACILITY DESIGN ANDRENOVATION (TAB K) DATED AUGUST 2011,THE ENGINNEERING TECHINCALLETTER, (ETL) 02-12: COMMUNICATIONS AND INFORMATION SYSTEM CRITERIAFOR AIR FORCE FACILITIES DATED 27 JUN 2002, AND THE UNIFIED FACILITIESCRITERIA (UFC) UFC-3-580-01, TELECOMMUNIACTION BUILDING CABLINGSYSTEMS PLANNING AND DESIGN DATED 27 JUN 2007.

2. THE POINT OF CONTACT FOR THIS PROJECT IS RICHARD TAYLOR, 75ABW/SCXP, (W) 801-775-5392. THE CONTRACTOR SHALL NOTIFY ANDCOORDINATE WITH SCXP OFFICE TO PERFORM AN ON SITE MEETING BEFOREBEGINNING ANY WORK.

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 7:

59:5

7 AM

As in

d icate

dEL

ECTR

ICAL

ENL

ARGE

D PL

AN

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

10/13

/14

E-401

M. R

OSAL

ES

SHEET 133 OF

2 JUL

Y 20

15G.

GO I

NS

SCALE: 1/4" = 1'-0"1 ENLARGED KITCHEN PLAN

NOTES

1 ALL 120V, 20A, 1P DUPLEX, GFI UNLESSNOTED.

2 J-BOX FOR GAS SHUT-OFF SOLENOID.INTERLOCK WITH HOOD FIRE ALARM SYSTEM.

3 VERIFY ACTUAL WIRING REQUIREMENTS WITHSUPPLIER.

4 1" C (3) CAT. 6 TO CER.

' '

GENERAL NOTES

A. REFER TO EQUIPMENT CONNECTIONSCHEDULE ON SHEET E-600 FORADDITIONAL INFORMATION ANDREQUIREMENTS. PROVIDE COMPLETEELECTRICAL CONNECTION TO ALLEQUIPMENT REQUIRING POWER UNLESSNOTED OTHERWISE.

B. COORDINATE EXACT MECHANICAL EQUIPMENTLOCATIONS AND REQUIREMENTS WITHMECHANICAL CONTRACTOR PRIOR TOROUGH-IN.

SCALE: 1/4" = 1'-0"2 ENLARGED BANQUET PREPSCALE: 12" = 1'-0"3 DETAIL 1

N

PLANNORTH

0'

SCALE : 1/4" = 1'-0"

2' 4' 8'

N

PLANNORTH

0'

SCALE : 1/4" = 1'-0"

2' 4' 8'

SCALE: 1/4" = 1'-0"4 ENLARGED COMM ROOM

SCALE: 12" = 1'-0"5 GROUND BAR INSTALLATION DIAGRAM

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 7:

59:5

7 AM

ELEC

TRIC

AL S

CHED

ULES

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

10/13

/14

E-600

M. R

OSAL

ES

SHEET 134 OF

2 JUL

Y 20

15G.

GO I

NS

LIGHTING FIXTURE SCHEDULEMANUFACTURER & LAMPS PER FIXTURE TOTAL

TAG MODEL NUMBER NO. TYPE VA VOLTAGE MOUNTING DESCRIPTION AND OPTIONSA ATLANTIC LIGHTING LED DIMMING DOWNLIGHT

LED6-DLM30-35K-CL LED LED 36 120 FLUSHA1 ATLANTIC LIGHTING LED DIMMING DOWNLIGHT WITH BATTERY PACK

LED6-DLM30-35K-CL- LEM LED LED 36 120 FLUSHA2 ATLANTIC LIGHTING LED DIMMING DOWNLIGHT

LED6-DLM20-35K-CL LED LED 20 120 FLUSHA3 ATLANTIC LIGHTING LED DIMMING DOWNLIGHT

LED6-DLM11-35K-CL- LEM LED LED 10 120 FLUSHA4 ATLANTIC LIGHTING LED LED 10 120 FLUSH LED DIMMING DOWNLIGHT WITH BATTERY PACK

LED6-DLM11-35K-CL- LEMB COLUMBIA LIGHTING 2X4 LIGHT FIXTURE IN GYPBOARD CEILING

JT8-24-2- 32-FLANGE-FS-A12-.125-E-U-G2 2 T8 65 120 FLUSHB1 COLUMBIA LIGHTING 2X4 LIGHT FIXTURE IN GYPBOARD CEILING

JT8-24-2- 32-FLANGE-FS-A12-.125-E-U-G2-EL 2 T8 65 120 FLUSH WITH BATTERY PACK.B2 COLUMBIA LIGHTING 2X4 LIGHT FIXTURE IN GYPBOARD CEILING

JT8-24-2- 32-FLANGE-FS-A12-.125-E-U-G2 4 T8 128 120 FLUSHB3 COLUMBIA LIGHTING 2X4 LIGHT FIXTURE IN GYPBOARD CEILING

JT8-24-2- 32-FLANGE-FS-A12-.125-E-U-G2-EL 4 T8 128 120 FLUSH WITH BATTERY PACK.C HALO TRACK HEAD. PROVIDE SINGLE CIRCUIT

L807HO LED LED 34 120 TRACK HALO TRACK/ PENDANT MOUNT TRACK.D COLUMBIA LIGHTING

LCR-4-35-ML-E-U LED LED 48 120 SURFACEF COLUMBIA LIGHTING LED LENS STRIP LIGHT

LCL-4-35-ML-E-U LED LED 48 120 SURFACEF1 COLUMBIA LIGHTING LED LENS STRIP LIGHT

LCL-4-35-ML-E-U-ELL14 LED LED 48 120 SURFACE WITH BATTERY PACK.G SPAULDING LIGHTING WALL MOUNTED EXIT WAY LIGHT

LMC-30LU-4K-3-035-4-BBU277 LED LED 35 120 WALL WITH -20DEG. C BATTERY PACK.X DUAL-LITE WALL EXIT LIGHT, LED WITH BATTERY PACK.

EVE-U-R-W-E LED LED 2.1 120 CEILINGH PHILIPS GARDCO LED LED 105 120 20'-0" LED SITE LIGHTING WITH INTREGRAL MOTION

P21-MRI-A1-1-III-105-NW-120-WHITE RD POLE. SENSOR FOR 50% LIGHTING LEVEL REDUCTION.K COLUMBIA LIGHTING 3 T8-17 52 120 FLUSH 2X2 FIXTURE IN GYPBOARD CEILING

JT8-22-3-17-FLANGE-A12.125-E-U-G1K1 COLUMBIA LIGHTING 3 T8-17 52 120 FLUSH 2X2 FIXTURE IN GYPBOARD CEILING

JT8-22-3-17-FLANGE-A12.125-E-U-G1-EL WIITH BATTERY PACKLIGHTING FIXTURE SCHEDULE NOTES

1. FIXTURES INDICATED ABOVE SHALL BE USED AS BASIS FOR ALL BIDDING. ANY ALTERNATE LIGHT FIXTURE PACKAGES SHALL BE SUBMITTED ATTIME OF BID WITH ASSOCIATED LINE ITEM COST SAVINGS FOR EACH FIXTURE AND APPROVED BY OWNER. IF ALTERNATE FIXTURE PACKAGE ISNOT SUBMITTED OR APPROVED, ADDITIONAL SUBSTITUTIONS WILL ONLY BE ACCEPTED AT THE ARCHITECT/ENGINEERS REQUEST.

2. MANUFACTURER'S SERIES SHOWN INDICATE BASIC FIXTURE TYPES REQUIRED FOR THIS PROJECT. VERIFY WITH MANUFACTURER TO INCLUDE ALLACCESSORIES REQUIRED FOR ACTUAL INSTALLATION.

3. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING FIXTURE LOCATIONS, MOUNTING REQUIREMENTS AND U.L. LABELING OF FIXTURESPRIOR TO ORDERING. INCLUDE MOUNTING CLIPS, HARDWARE, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION.

4. WHERE INDICATED ON DRAWINGS AS EMERGENCY FIXTURE, PROVIDE FACTORY INSTALLED OPTIONAL EMERGENCY BATTERY PACK TO OPERATEOUTBOARD LAMPS. LAMPS ARE TO BE SWITCHED WITH REMAINING FIXTURES IN THIS AREA.

5. ALL EMERGENCY LIGHTING FIXTURES SHALL BE PROVIDED WITH 90 MINUTES OF BATTERY BACK UP WITH A MINIMUM 1400 LUMEN OUTPUTOPERATION IN THE EMERGENCY MODE UNLESS NOTED OTHERWISE. EXTEND AN UN-SWITCHED LOCAL LIGHTING BRANCH CIRCUIT TO BATTERYBALLAST UNIT. FIXTURE SHALL OPERATE WITH LOCAL ROOM SWITCH AND UPONLOSS OF UTILITY POWER WILL OPERATE LAMPS ON BATTERY BACKUP UNLESS NOTED OTHERWISE.

6. WHERE LOW MERCURY CONTENT LAMPS ARE USED, EMERGENCY BATTERY PACKS COMPATIBLE WITH LOW MERCURY CONTENT LAMPS SHALL BE USED.

KITCHEN EQUIPMENT CONNECTION SCHEDULETAG DESCRIPTION

LOAD DATA VOLT/ DISCONNECT STARTER * FEEDER SIZENOTES

HP KW FLA MCA MOCP PHASE SIZE (AMPS) ENCLOSURE TYPE SIZE (NEMA) (SEE FEEDER SCHEDULE)

1 AIR CURTAIN 10.2 20A 20A 120 PROVIDE DOOR SWITCHES.021

6 WORK TABLE 6 20A 20A 120 GFI DUPLEX CTR. HEIGHT.021

13 ICE MAKER 16 20A 20A 208/1 DIRECT CONNECTION023

24 FIRE SUPPRESSION 6 20A 20A 120 021

27 WORK TABLE 6 20A 20A 120 GFI DUPLEX CTR HEIGHT.021

35WALK-IN COOLER

LIGHTS 6 20A 20A 120 LIGHTS,DOOR HTR021

36 COOLER EVAP 2 4A 20A 120 1,2,3021

41WALK-IN FREEZER

LIGHTS 6 20A 20A 120 LIGHTS,DOOR HTR021

42 FREEZER EVAP 10 20A 20A 208/1 1,2,3031

51 REFRIG. STAND 8.4 20A 20A 120 GFI DUPLEX021

54 FRYER PUMP 7 20A 20A 120 GFI RECEP021

54 FRYER CONTROLS 1.7 20A 20A 120 GFI RECEP021

000

56 HOOD LIGHTS 6 20A 20A 120 DIRECT CONNECTION.021

62 WORK COUNTER 6 20A 20A 120 GFI RECEP021

64 CASH REGISTER 6 20A 20A 120 GFI RECEP021

65 U.C. REFRIG. 6.3 20A 20A 120 GFI RECEP021

66U.C. HEATEDCABINET 8 20A 20A 120 GFI RECEP021

67 SERVICE COUNTER 6 20A 20A 120 GFI RECEP021

71 SODA DISPENSER 7 20A 20A 120 GFI RECEP021

74 COOLER CONDENSER 8 15A 15A 208/1 1,2,3031

73 TRASH COUNTER 6 20A 20A 120 CTR GFI RECEP021

17 BULK CO2 6 20A 20A 120 021

30UNDER COUNTERDISHWASHER 39.6 50A 50A 208/1 60A 50A 1.2.3051

69 BEER TAP 6 20A 20A 120 RECEP +12"021

70UNDER COUNTER

KEG 6.5 20A 20A 120 1,2,3021

72 SOUP WELL 9.2 20A 20A 120 021

74 REMOTE REFRIG UNIT 10 24A 25A 208/3 1,2,3033

SCHEDULE NOTES:* = ELECTRICAL CONTRACTOR TO PROVIDE OVERLOAD PROTECTION.

1. MAKE FINAL CONNECTION TO EQUIPMENT.2. VERIFY EXACT LOCATION AND REQUIREMENTS WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN. STARTER TYPES:3. FUSE SIZE PER MANUFACTURER'S REQUIREMENTS. FVNR FULL VOLTAGE NON-REVERSING4. VARIABLE SPEED DRIVE FURNISHED BY MECHANICAL AND INSTALLED BY ELECTRICAL. FVR FULL VOLTAGE REVERSING5. SINGLE POINT CONNECTION TO FUSED DISCONNECT/POWER PANEL. UNIT IS LOCATED INDOORS. TSOW TWO SPEED ONE WINDING6. SINGLE POINT CONNECTION TO FUSED DISCONNECT/POWER PANEL. UNIT IS LOCATED OUTDOORS. TSTW TWO SPEED TWO WINDING7. SINGLE POINT CONNECTION TO CONTROL PANEL. AUTOXFMR REDUCED VOLTAGE AUTOTRANSFORMER8. PROVIDE A TOGGLE SWITCH AS THE DISCONNECTING MEANS. PW REDUCED VOLTAGE PART WINDING9. INDOOR UNIT IS FED FROM THE OUTDOOR UNIT. Y-ΔOT REDUCED VOLTAGE Y-Δ OPEN TRANSITION10. DISCONNECT IS PROVIDED WITH THE EQUIPMENT. Y-ΔCT REDUCED VOLTAGE Y-Δ CLOSED TRANSITION11. STARTER IS PROVIDED WITH THE EQUIPMENT. VFD VARIABLE FREQUENCY DRIVE12. PROVIDE STARTER WITH HOA SELECTOR SWITCH.13. PROVIDE STARTER WITH ON/OFF SELECTOR SWITCH.14. PROVIDE STARTER WITH START/STOP PUSH BUTTONS.15. PROVIDE STARTER WITH START/STOP/JOG PUSH BUTTONS.16. PROVIDE STARTER WITH TWO N.O. CONTACTS.17. PROVIDE STARTER WITH TWO N.C. CONTACTS.18. PROVIDE STARTER WITH PHASE FAILURE RELAY.19. DISCONNECTING MEANS ACTS AS MANUAL CONTROL OF THE CIRCULATION PUMP.

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 7:

59:5

9 AM

ELEC

TRIC

AL S

CHED

ULES

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

04/02

/15

E-601

M. R

OSAL

ES

SHEET 135 OF

2 JUL

Y 20

15G.

GO I

NS

6/24/15 10:26 AM NEW

PANELBOARD A SCHEDULEVOLTAGE: 120/208 V, 3 Ph, 4 W LOCATION: ELEC. RMBUS RATING: 225 A ENCL. NEMA 1MAINS: MLO LOAD - VA MOUNTING: SURFACETYPE: BOLT ON MIN AIC 42000

CKT PHASE PHASE PHASE CKTCIRCUIT DESCRIPTION BKR NUM A B C NUM BKR CIRCUIT DESCRIPTIONLTG. LCP TIMECLOCK 20 1 1,365 20

1 789 2 1 LTGLTG. LCP TIMECLOCK 20 3 1,365 20

1 455 4 1 LTGLTG. LCP TIMECLOCK 20 5 1,170 20

1 1,014 6 1 LTGLTG. LCP TIMECLOCK 20 7 936 20

1 520 8 1 LTGLTG. LCP TIMECLOCK 20 9 351 20

1 10 1 SPARELTG. LCP TIMECLOCK 20 11 730 20

1 12 1 SPARELTG. LCP TIMECLOCK 20 13 780 20

1 540 14 1 RECEPLTG. LCP TIMECLOCK 20 15 1,349 20

1 540 16 1 RECEPLTG. LCP TIMECLOCK 20 17 858 20

1 720 18 1 RECEPLTG. LCP TIMECLOCK 20 19 156 20

1 720 20 1 RECEPLTG. LCP PHOTOCELL 20 21 195 20

1 540 22 1 RECEPLTG. LCP PHOTOCELL 20 23 80 20

1 360 24 1 RECEPRECEP 20 25 800 20

1 360 26 1 RECEPRECEP 20 27 540 20

1 360 28 1 RECEPRECEP 20 29 720 20

1 360 30 1 RECEPRECEP 20 31 800 20

1 720 32 1 RECEPRECEP 20 33 540 20

1 720 34 1 RECEPRECEP 20 35 900 20

1 720 36 1 RECEPRECEP 20 37 900 20

1 360 38 1 RECEPRECEP 20 39 720 20

1 540 40 1 RECEPRECEP 20 41 360 20

1 540 42 1 RECEPRECEP 20 43 360 20

1 800 44 1 RECEP EWCRECEP 20 45 180 20

1 800 46 1 RECEP EWCRECEP CER 20 47 360 20

720 48 1 RECEPRECEP CER 49 360 20

2 50 1 SPARESPARE 20 51 20

1 52 1 SPARESPARE 20 53 20

1 54 1 SPARESPARE 20 55 20

1 56 1 SPARESPARE 20 57 20

1 58 1 SPARESTORM HEAT TRACE 20 59 20

1 60 1 SPAREFEED THROUGH LOAD NOTES

CONNECTED LOAD 11,266 9,195 10,759DEMAND LOAD 9,777 7,981 9,483DESIGN LOAD 10,913 8,909 10,445LINE AMPS 90.9 74.2 87.0

DESIGN LOAD KVA 30.3

6/24/15 10:26 AM NEW

PANELBOARD B SCHEDULEVOLTAGE: 120/208 V, 3 Ph, 4 W LOCATION: ELEC. RMBUS RATING: 225 A ENCL. NEMA 1MAINS: MLO LOAD - VA MOUNTING: SURFACETYPE: BOLT ON MIN AIC 42000

CKT PHASE PHASE PHASE CKTCIRCUIT DESCRIPTION BKR NUM A B C NUM BKR CIRCUIT DESCRIPTIONSITE LIGHT 20 1 420 20

1 75 2 FC-1.8, FC-1.9HP-C3 20 3 1,352

75 4 2 FC-1.8, FC-1.9HP-C3 5 1,352 20

2 1,009 6 FC-6CP-1, CP-2 20 7 200

1,009 8 2 FC-6CP-1, CP-2 9 200 20

2 106 10 FC-1, FC-2WH-1 CONTROL 20 11 200

1 106 12 2 FC-1, FC-2ROOF RECEPS 20 13 540 20

1 53 14 FC-4HEAT TRACE 20 15 1,100

1 53 16 2 FC-4SPACE ONLY 17 20

600 18 FC-3SPACE ONLY 19

600 20 2 FC-3SPACE ONLY 21 20

1,010 22 FC-5SPACE ONLY 23

1,010 24 2 FC-5SPACE ONLY 25 20

700 26 FC-7SPACE ONLY 27

700 28 2 FC-7SPACE ONLY 29 20

55 30 BC-1.1, BC-1.2SPACE ONLY 31

55 32 2 BC-1.1, BC-1.2SPACE ONLY 33

34 SPACE ONLYSPACE ONLY 35

36 SPACE ONLYSPACE ONLY 37

38 SPACE ONLYSPACE ONLY 39

40 SPACE ONLYSPACE ONLY 41

42 SPACE ONLYFEED THROUGH LOAD NOTES

CONNECTED LOAD 3,632 4,469 4,331 PROVIDE 30ma GFCI C/B ON CIRC. 15DEMAND LOAD 3,632 4,469 4,331DESIGN LOAD 4,073 4,804 4,331LINE AMPS 33.9 40.0 36.1

DESIGN LOAD KVA 13.2

5/19/15 8:43 AM NEW

PANELBOARD K SCHEDULEVOLTAGE: 120/208 V, 3 Ph, 4 W LOCATION: ELEC. RMBUS RATING: 225 A ENCL. NEMA 1MAINS: MLO LOAD - VA MOUNTING: SURFACETYPE: BOLT ON MIN AIC 42000

CKT PHASE PHASE PHASE CKTCIRCUIT DESCRIPTION BKR NUM A B C NUM BKR CIRCUIT DESCRIPTIONRECEP. ITEM 73 20 1 720 20

1 600 2 1 GAS SOLENOID ST.RECEP. ITEM 71 20 3 840 20

1 1,200 4 1 RECEP. ITEM 54RECEP. ITEM 64 20 5 720 20

1 1,200 6 1 RECEP. ITEM 54RECEP. ITEM 67 20 7 180 20

1 200 8 1 RECEP. ITEM 53RECEP. ITEM 65 20 9 800 20

1 200 10 1 RECEP. ITEM 52RECEP. ITEM 66 20 11 960 20

1 1,000 12 1 RECEP. ITEM 51RECEP. ITEM 70 20 13 800 20

1 200 14 1 RECEP. ITEM 47RECEP. ITEM 69 20 15 720 20

1 200 16 1 RECEP. ITEM 46RECEP. ITEM 67 20 17 180 20

1 500 18 1 JBOX ITEM 56RECEP. ITEM 72 20 19 1,200 20

1 500 20 1 RECEP. ITEM 17RECEP. 20 21 360 20

1 1,200 22 1 JBOX ITEM 41RECEP. 20 23 360 20

1 1,200 24 1 JBOX ITEM 35D/S ITEM 30 40 25 3,852 20

240 26 1 COOLER EVAP ITEM 42D/S ITEM 30 27 3,852

240 28 2 COOLER EVAP ITEM 42D/S ITEM 30 29 3,852 20

3 1,200 30 FREEZER EVAP ITEM 36RECEP. ITEM 62 20 31 720

1 1,200 32 2 FREEZER EVAP ITEM 36RECEP. ITEM 27 20 33 720 20

1 1,200 34 D/S ON ROOF ITEM 74ANSUL SYSTEM 20 35 200

1 1,200 36 2 D/S ON ROOF ITEM 74D/S ITEM 74 ON ROOF 20 37 1,200 20

1,800 38 JBOX ITEM 13D/S ITEM 74 ON ROOF 39 1,200

1,800 40 2 JBOX ITEM 13D/S ITEM 74 ON ROOF 41 1,200 20

3 360 42 1 RECEP ITEM 6FLY FAN 20 43 1,200 20

1 360 44 1 RECEP. ITEM 6MOBILE CART 20 45 1,200 20

1 360 46 1 RECEP. ITEM 6MOBILE CART 20 47 1,200

1 48 SPACE ONLYRECEPTACLE 20 49 180

1 50 SPACE ONLYRECEPTACLE 20 51 180

1 52 SPACE ONLYSPACE ONLY 53

54 SPACE ONLYSPACE ONLY 55

56 SPACE ONLYSPACE ONLY 57

58 SPACE ONLYSPACE ONLY 59

60 SPACE ONLYFEED THROUGH LOAD NOTES

CONNECTED LOAD 15,152 16,032 15,332 COPPER BUSDEMAND LOAD 9,849 10,421 9,966DESIGN LOAD 9,849 10,421 9,966LINE AMPS 82.1 86.8 83.0

DESIGN LOAD KVA 30.2

1200

CIRC 59 TO BE 30ma GFCI BREAKER

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 8:

00:0

0 AM

ELEC

TRIC

AL S

CHED

ULES

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

Chec

k er

Appro

ver

05/27

/15

E-602

Autho

r

SHEET 136 OF

2 JUL

Y 20

15De

signe

r

EQUIPMENT CONNECTION SCHEDULETAG DESCRIPTION

LOAD DATA VOLT/ DISCONNECT STARTER * FEEDER SIZENOTES

HP KW FLA MCA MOCP PHASE SIZE (AMPS) ENCLOSURE TYPE SIZE (NEMA) (SEE FEEDER SCHEDULE)

RTU-1 ROOF TOP UNIT 42.7 60A 208/3 60 3R 1, 2, 3063

ERV-1 ENERGY RECOVERY 33.9 50A 208/3 60 3R 1, 2, 3053

MAU-1 MAKE UP AIR UNIT 12.3 20A 208/3 30 3R 1, 2, 3033

KEF-1 KITCHEN EXHAUST FAN 1.5 6.6 20A 208/3 30 3R FVNR 1 1, 2, 3033

CU-1 CONDENSER 37.8 50A 208/3 60 3R 1, 2, 3053

CP-1,CP-2 CIRCULATING PUMPS 1/8 2 20A 208/1 30 1 1, 2, 3021

HP-C3 SPLIT SYSTEM 13 15A 208/1 30 3R 1, 2, 3, 9023

FC-1 FAN COIL 0.11 15A 208/1 30 1 1, 2, 3023

FC-2 FAN COIL 0.11 15A 208/1 30 1 1, 2, 3023

FC-3 FAN COIL 1.2 15A 208/1 30 1 1, 2, 3023

FC-4 FAN COIL 0.11 15A 208/1 30 1 1, 2, 3023

FC-5 FAN COIL 2.02 20A 208/1 30 1 1, 2, 3023

FC-6 FAN COIL 2.02 20A 208/1 30 1 1, 2, 3023

FC-7 FAN COIL 1.32 20A 208/1 30 1 1, 2, 3023

FC-1.8 FAN COIL 0.08 15A 208/1 30 1 1, 2, 3023

FC-1.9 FAN COIL 0.08 15A 208/1 30 1 1, 2, 3023

SCHEDULE NOTES:* = ELECTRICAL CONTRACTOR TO PROVIDE OVERLOAD PROTECTION.

1. MAKE FINAL CONNECTION TO EQUIPMENT.2. VERIFY EXACT LOCATION AND REQUIREMENTS WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN. STARTER TYPES:3. FUSE SIZE PER MANUFACTURER'S REQUIREMENTS. FVNR FULL VOLTAGE NON-REVERSING4. VARIABLE SPEED DRIVE FURNISHED BY MECHANICAL AND INSTALLED BY ELECTRICAL. FVR FULL VOLTAGE REVERSING5. SINGLE POINT CONNECTION TO FUSED DISCONNECT/POWER PANEL. UNIT IS LOCATED INDOORS. TSOW TWO SPEED ONE WINDING6. SINGLE POINT CONNECTION TO FUSED DISCONNECT/POWER PANEL. UNIT IS LOCATED OUTDOORS. TSTW TWO SPEED TWO WINDING7. SINGLE POINT CONNECTION TO CONTROL PANEL. AUTOXFMR REDUCED VOLTAGE AUTOTRANSFORMER8. PROVIDE A TOGGLE SWITCH AS THE DISCONNECTING MEANS. PW REDUCED VOLTAGE PART WINDING9. INDOOR UNIT IS FED FROM THE OUTDOOR UNIT. Y-ΔOT REDUCED VOLTAGE Y-Δ OPEN TRANSITION10. DISCONNECT IS PROVIDED WITH THE EQUIPMENT. Y-ΔCT REDUCED VOLTAGE Y-Δ CLOSED TRANSITION11. STARTER IS PROVIDED WITH THE EQUIPMENT. VFD VARIABLE FREQUENCY DRIVE12. PROVIDE STARTER WITH HOA SELECTOR SWITCH.13. PROVIDE STARTER WITH ON/OFF SELECTOR SWITCH.14. PROVIDE STARTER WITH START/STOP PUSH BUTTONS.15. PROVIDE STARTER WITH START/STOP/JOG PUSH BUTTONS.16. PROVIDE STARTER WITH TWO N.O. CONTACTS.17. PROVIDE STARTER WITH TWO N.C. CONTACTS.18. PROVIDE STARTER WITH PHASE FAILURE RELAY.19. DISCONNECTING MEANS ACTS AS MANUAL CONTROL OF THE CIRCULATION PUMP.

DESIGN LOAD TOTALS BY LOAD TYPE - MSA ASSIGNED

Phase A Phase B Phase C Total pf

GENERAL LOADS 0 1,100 200 1,300 0.90

LIGHTING LOADS - GENERAL 6,208 4,644 4,815 15,666 0.95

LIGHTING LOADS - HOSPITAL 220.14 0 0 0 0 0.95

LIGHTING LOADS - WAREHOUSE 220.14 0 0 0 0 0.95

LIGHTING LOADS - HOTEL ROOM 220.14 0 0 0 0 0.95

LIGHTING LOADS - RESIDENTIAL 220.14 0 0 0 0 0.95

RECEPTACLES - GENERAL 220.14(I) 5,592 4,221 4,437 14,250 0.95

FIXED APPLIANCES - RESIDENTIAL 220.53 0 0 0 0 0.95

ELECTRIC DRYER - RESIDENTIAL 220.54 0 0 0 0 1.00

ELECTRIC RANGE - RESIDENTIAL 220.55 0 0 0 0 1.00

ELECTRONIC EQUIPMENT 0 0 0 0 0.95

HEATING LOADS 0 0 0 0 1.00

KITCHEN LOADS - COMMERCIAL 220.56 10,364 10,936 10,481 31,780 0.90

CAPACITOR 0 0 0 0 0.00

HVAC EQUIPMENT 440 17,696 18,500 19,336 55,532 0.85

MOTOR LOADS 430 3,800 3,800 3,600 11,200 0.85

FIRE PUMPS 695 0 0 0 0 0.85

CRANES AND HOISTS 610 0 0 0 0 0.85

ELEVATORS 620 0 0 0 0 0.85

ELECTRIC ARC WELDERS 630 0 0 0 0 0.85

ELECTRIC RESISTANCE WELDERS 630 0 0 0 0 1.00

X-RAY EQUIPMENT 660 0 0 0 0 0.95

LARGEST MOTOR (25%) 1,281 1,281 1,281 3,843 0.85

Total Demand VA 44,720 44,294 43,955 132,967 0.89

AMPS 372.7 369.1 366.3 369.1

Harris Consulting Engineers, LLC 5/27/2015 15:02

SHORT CIRCUIT AND VOLTAGE DROP ANALYSISBus Description Amp Load AIC Isc Voltage %

Number Rating Amps kVA Rating (at Bus) Drop Drop

B1 Utility - - - - 90,933 0.00 0.00%B2 MSA 800 MCB 369 133.0 65,000 45,764 1.54 0.74%B3 A 225 MLO 81 29.1 42,000 35,841 1.80 0.86%B4 K 225 MLO 84 30.2 42,000 29,228 2.05 0.98%B5 B 225 MLO 37 13.3 42,000 29,228 2.05 0.98%

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 8:

00:0

1 AM

LIGH

TING

IECC

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

G. G

O INS

P. W

H ISE

NHUN

T 05/19

/15

E-603

M. R

OSAL

ES

SHEET 137 OF

2 JUL

Y 20

15G.

GO I

NS

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 8:

00:0

2 AM

LIGH

TING

IECC

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

05/19

/15

E-604

M. R

OSAL

ES

SHEET 138 OF

2 JUL

Y 20

15G.

GO I

NS

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 8:

00:0

2 AM

LIGH

TING

IECC

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

05/19

/15

E-605

M. R

OSAL

ES

SHEET 139 OF

2 JUL

Y 20

15G.

GO I

NS

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

TRANSFORMER

1120/208V, 3Ø, 4W

300 KVA

450A3P

EXISTINGXFMR

2

225A3P

3

225A3P

4

60A3P

5

60A3P

11

60A3P800A

3P

'K'PANEL

'B'PANEL

224

'A'PANEL

224404

12.47KV 800A - 120/208V, 3Ø, 4W 65K AIC

804

4"C (3) #1/0, 15KV, CU133% #1 BARE CUGROUND

6

50A3P

7

20A3P

8

20A3P

9

50A3P

10

053

CU-1

033

KEF-1

033

MAV-1

063

RTU-1

053

ERV

12

100A3P

13

60A3P

SPACE SPACE

'MSA'

25E

9KV

CW

BLDG.PIPING

GN

STEEL

(1) CAT. 6TO CER

EXISTINGPRIMARYSERVICE

JENSEN PRE-CAST RS-84CONCRETE INTERCEPT BOX

RAYCHEM OR EQUALWATERTIGHT SPLICES

PROVIDE 1" CONDUITDRAIN TO DAYLIGHT

3'X4'X4' PULLBOXWITH FRENCH DRAIN

24"PEA GRAVEL

083

LIFTSTATION

42.7A 33.9A 12.3A 1.5HP6.6A

37.3A

60A3P

SPACESPACEFUTUREFIRE PUMPCONTROLLER

(2) 4"C WITH PULLSTRING

DM

NEWXFMR

EXSTINGXFMR

TO PRIMARY

TO SECONDARY

100A400A 400A

225A

CART BARN LEVEL

UPPER PARKING LEVEL

EXISTING POLE

LTS AND RADIO TOWERNEW FEEDER PARKING AREA

TO BE REMOVEDEXISTING WEATHERHEAD

4"C (3) #1/0, 15KV, CU133% #1 BARE CUGROUND. VERIFY PRIMARY

EXISTING TRANSFORMERAND DISCONNECTS TO REMAIN

NEW CONNECTION

EXISTING AERIALCABLE TO REMAIN

NEW

TERMINATION TYPE.

AREA LIGHTS AND RADIO TOWER.(4)#3 THWN, #6G, 1 1/4" C

PROVIDE NEW SERVICE TO PARKING

CART BARN TO REMAINEXISTING SERVICE TO

CLUBHOUSE TO BE REMOVED ASPART OF CLUBHOUSE DEMO

EXISTING SERVICE TO

TO SERVE PARKING AREA LIGHTSAND RADIO TOWER DURING SWITCHOVER

PROVIDE TEMPORARY GENERATOR

OF PRIMARY SERVICE. 120/208V3∅, 45 KVA

NEW PRIMARY SERVICE TO EXISTING TRANSFORMER

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CKD

BY:

SOLI C

ITAT

ION

NO.:

DATE

:

DRW

N BY

:

LEE

& SA

KAH

ARA

AR

CHIT

ECTU

RE P

LANN

ING

INTE

RIO

RS

ARC

HI T

ECT S

AIA

1684

2 Von

Kar

man A

ve.,

Suite

125,

Irvine

, CA

9260

6-49

34Te

l. (9

49) 2

61-1

100

Fax.

(949

) 261

-114

4 w w

w.lee

sak.c

om

DESI

GNED

BY:

SHEETIDENTIFICATION

154

CONT

RACT

NO .

:

FILE

NUM

BER:

PLOT

DAT

E:PL

OT S

CALE

:

SUBM

ITTE

D BY

:

SIZE

:FI

LE N

AME:

ANSI

D

1

A

SEAL

AIR

FORC

E SE

RVIC

ES A

CTIV

ITY

JBSA

LACK

LAND

SAN

ANTO

NIO,

TEX

ASF4

1999

-14-

F-14

22

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/14

/201

5 8:

00:0

4 AM

12" =

1'-0"

ELEC

TRIC

AL D

IAGR

AMS

GOLF

CLU

BHOU

SEHI

LL A

IR F

ORCE

BAS

E, U

TAH

P. W

H ISE

NHUN

T

G. G

O INS

10/13

/14

E-700

M. R

OSAL

ES

SHEET 140 OF

2 JUL

Y 20

15G.

GO I

NS

SCALE: NONE1 ELECTRICAL PARTIAL SINGLE LINE DIAGRAM

SCALE: NONE2 DISTRIBUTION DETAIL

FEEDER SCHEDULE - CuTwo Wire Feeders

Feeder Tag Conduit ConductorsQty Size Qty Size GND

021 1 ea 3/4" 2 ea 12 12

031 1 ea 3/4" 2 ea 10 10

041 1 ea 3/4" 2 ea 8 10

051 1 ea 3/4" 2 ea 6 10

061 1 ea 1" 2 ea 4 10

071 1 ea 1" 2 ea 4 8

081 1 ea 1" 2 ea 3 8

101 1 ea 1" 2 ea 2 8

111 1 ea 1 1/4" 2 ea 2 6

121 1 ea 1 1/4" 2 ea 1 6

151 1 ea 1 1/4" 2 ea 1/0 6

171 1 ea 1 1/2" 2 ea 2/0 6

201 1 ea 1 1/2" 2 ea 3/0 6

221 1 ea 2" 2 ea 4/0 4

251 1 ea 2" 2 ea 250 4

301 1 ea 2" 2 ea 350 4

FEEDER SCHEDULE - CuThree Wire Feeders

Feeder Tag Conduit Conductors

Qty Size Qty Size GND

023 1 ea 3/4" 3 ea 12 12

033 1 ea 3/4" 3 ea 10 10

043 1 ea 3/4" 3 ea 8 10

053 1 ea 1" 3 ea 6 10

063 1 ea 1" 3 ea 4 10

073 1 ea 1 1/4" 3 ea 4 8

083 1 ea 1 1/4" 3 ea 3 8

103 1 ea 1 1/4" 3 ea 2 8

113 1 ea 1 1/4" 3 ea 2 6

123 1 ea 1 1/2" 3 ea 1 6

153 1 ea 1 1/2" 3 ea 1/0 6

173 1 ea 2" 3 ea 2/0 6

203 1 ea 2" 3 ea 3/0 6

223 1 ea 2" 3 ea 4/0 4

253 1 ea 2 1/2" 3 ea 250 4

303 1 ea 3" 3 ea 350 4

353 1 ea 3" 3 ea 500 3

403 1 ea 3" 3 ea 500 3

453 2 ea 2" 3 ea 4/0 2

503 2 ea 2 1/2" 3 ea 250 2

603 2 ea 3" 3 ea 350 1

703 2 ea 3" 3 ea 400 1/0

803 2 ea 3" 3 ea 500 1/0

FEEDER SCHEDULE - CuFour Wire Feeders

Feeder Tag Conduit Conductors

Qty Size Qty Size GND

024 1 ea 3/4" 4 ea 12 12

034 1 ea 3/4" 4 ea 10 10

044 1 ea 1" 4 ea 8 10

054 1 ea 1" 4 ea 6 10

064 1 ea 1 1/4" 4 ea 4 10

074 1 ea 1 1/4" 4 ea 4 8

084 1 ea 1 1/4" 4 ea 3 8

104 1 ea 1 1/2" 4 ea 2 8

114 1 ea 1 1/2" 4 ea 2 6

124 1 ea 1 1/2" 4 ea 1 6

154 1 ea 2" 4 ea 1/0 6

174 1 ea 2" 4 ea 2/0 6

204 1 ea 2" 4 ea 3/0 6

224 1 ea 2 1/2" 4 ea 4/0 4

254 1 ea 3" 4 ea 250 4

304 1 ea 3" 4 ea 350 4

354 1 ea 3 1/2" 4 ea 500 3

404 1 ea 3 1/2" 4 ea 500 3

454 2 ea 2 1/2" 4 ea 4/0 2

504 2 ea 3" 4 ea 250 2

604 2 ea 3" 4 ea 350 1

704 2 ea 3" 4 ea 400 1/0

804 2 ea 3 1/2" 4 ea 500 1/0

NOTES:1. Conduit size is based on EMT, RMC, schedule 80

PVC, FMC, and LTFMC. Contractor may increaseconduit size as permitted in the specifications.

2. All conductors shall be THHN/THWN, 90 degree C,Copper conductors. Conductors shown shall be

installed in each conduit.3. When the overcurrent device is larger than the

circuit ampacity shown above, (ie. motor circuitscovered by NEC 430), size the ground "GND"conductor per NEC 250-122.

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

.

PROF

ESS I

ONA L ENGINEER - STATEOF

NEVADAPROF

ESS I

ONA L ENGINEER - STATEOF

NEVADA

ELECTRICAL

WHISENHUNTPHILLIP A.

JUN 30 2016

No . 0 5 3 1No . 0 15 3 9 1

EXP.

July 16, 2015

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:4

5 P

M

SY

MB

OLS

, N

OT

ES

, &

IND

EX

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

03/2

2/12

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-100

Aut

hor

16 J

ULY

201

5

GENERAL SYMBOLS

ELEVATION REFERENCE

MULTIPLE ELEVATION REFERENCE

DETAIL REFERENCE

SECTION REFERENCE

ENLARGED PLAN/ DETAIL REFERENCE

SPECIFICATION REFERENCESEE TYPICAL SPECIFICATION SYMBOLS(ON INTERIOR DRAWINGS)

ITEM NUMBER

REVISION DELTA

+8'-0" ELEVATION HEIGHT REFERENCE

#

x

P-1

#FS-701

#FS-801

#FS-801

FS-701

#

1

34 2

FS-701

SHEET INDEX

SheetNumber Sheet Name

QF-100 SYMBOLS, NOTES, & INDEX

QF-101 EQUIPMENT FLOOR PLAN

QF-201 EQUIPMENT SCHEDULE

QF-202 EQUIPMENT SCHEDULE

QF-301 PLUMBING PLAN

QF-401 ELECTRICAL PLAN

QF-501 REFRIGERATION & CONDUIT PLAN

QF-601 BUILDING WORKS & EXHAUST PLAN

QF-602 HOOD DETAILS

QF-603 HOOD DETAILS

QF-701 EQUIPMENT ELEVATIONS

QF-702 EQUIPMENT ELEVATIONS

QF-801 CONSTRUCTION DETAILS

QF-802 EQUIPMENT SECTIONS

GENERAL NOTES

1 THESE PLANS ARE A GENERAL ARRANGEMENT OF EQUIPMENT FOR THECONVENIENCE OF CONTRACTORS AND IS MADE FROM AVAILABLE INFORMATION.FABRICATORS, CONTRACTORS, AND OTHERS UTILIZING THESE PLANS INCONNECTION WITH THIS JOB ARE RESPONSIBLE FOR SECURING THEIR OWNMEASUREMENTS FOR PREPARATION OF SUBMITTALS AND CONSTRUCTION.PLUMBING AND ELECTRICAL INFORMATION INDICATED ON THESE PLANS AREGENERALLY FOR FOOD SERVICE EQUIPMENT AND ARE INTENDED AS REFERENCEONLY. CONTRACTORS ARE TO MAKE ALLOWANCE FOR ELBOWS, TRAPS, ETC. ANDARE TO MAKE FINAL CONNECTIONS ON THE JOB, SUPPLYING ALL NECESSARYVALVES, TRAPS, STEAM TRAPS, FAUCETS, STARTING SWITCHES FOR MOTORS, ETC.EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE IN THE WRITTENSPECIFICATIONS.

2 ANY DISCREPANCIES BETWEEN PLANS, BUILDING, AND LOCAL CODE REQUIREMENTSTHAT MAY AFFECT THE INSTALLATION, FABRICATION, OR OVERALL WORK IN ANYWAY SHALL BE BROUGHT TO THE ATTENTION OF THE FOOD SERVICE EQUIPMENTCONTRACTOR IMMEDIATELY.

3 IT SHALL BECOME THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO INSURETHAT THE FOOD SERVICE EQUIPMENT CONTRACTOR RECEIVES COPIES OF ALLADDENDUMS AND CHANGES TO THE BUILDING PLANS, PRIOR TO, OR DURINGCONSTRUCTION WHEREAS, ADDENDUMS AND/OR CHANGES AFFECT ANY AREASPERTINENT TO THE FOOD AND BEVERAGE PORTION OF THE PROJECT.

4 IF THERE ARE ANY AMBIGUITIES, DISCREPANCIES, OR IRREGULARITIES, VERIFY WITHCONTRACTING OFFICER PRIOR TO COMMENCING WORK.

5 ALL WORK IS TO BE COMPLETED IN CRAFTSMAN LIKE MANNER AND CONFORM TOALL APPLICABLE BUILDING AND SAFETY CODES.

6 REFER TO ARCHITECTURAL PLANS FOR ADA CLEARANCE REQUIREMENTS FOR ALLSPACES, DOOR STRIKES, EXITS, AND AISLE WAYS AS THEY PERTAIN TO CODEENFORCEMENT AND INTERPRETATION.

7 CONTRACTORS SHALL SUBMIT ALL SHOP DRAWINGS, FINISHES, STAINS, ANDCOLORS TO THE CONTRACTING OFFICER FOR APPROVAL PRIOR TO FABRICATION.

8 SEE ENGINEERING DOCUMENTS FOR TITLE 24 ENGINEERING CALCULATIONS FORBUILDING PERMIT REQUIREMENTS.

9 CONTRACTOR TO VERIFY ALL EQUIPMENT CLEARANCES THRU BUILDING DOORS,HALLWAYS, OR ENTRY POINTS. NOT ALL EQUIPMENT WILL FIT THRU STANDARDDOOR OPENINGS.

10 VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO PROCEEDINGWITH WORK.

11 PARTITIONS ARE DIMENSIONED FROM FINISHED SURFACE, UNLESS OTHERWISENOTED.

12 ALL HORIZONTAL DIMENSIONS ARE FROM FINISHED FACE OF WALL TO FINISHEDFACE OF WALL OR CENTERLINE OF COLUMN.

13 ALL VERTICAL DIMENSIONS ARE FROM FINISHED FLOOR TO WALL OR WALL OPENING.

14 PROVIDE SMOOTH AND LEVEL FLOORS BELOW ALL KITCHEN EQUIPMENT UNLESSTHESE DRAWINGS SHOW OTHERWISE.

15 GENERAL CONTRACTOR TO PROVIDE AND INSTALL BLOCKING IN WALLS FORMOUNTING WALL SHELVES, POT RACKS, DISPLAY CASES, HOSE REELS, ETC., ASSHOWN ON PLANS.

16 WHERE REQUIRED, SPRINKLER HEADS IN WALK-IN FREEZER WILL BE PROVIDED BYAND PROTECTED AGAINST FREEZING BY GENERAL CONTRACTOR.

17 LEVEL PLATFORMS CONSTRUCTED PER CODE AND LOCATED ON ROOF AREREQUIRED FOR COMPRESSOR. REFER TO ARCHITECTURAL AND MECHANICAL PLANS.(VERIFY LOCATION)

18 VERIFY AND COORDINATE EXACT LOCATION OF COMPRESSOR RACK(S) WITHCONTRACTING OFFICER AND PROVIDE ACCESS FOR DELIVERY AND INSTALLATIONOF EACH COMPRESSOR RACK.

19 SEE PLANS FOR STRUCTURAL SUPPORT REQUIREMENTS OF ROOF SUPPORTING ALLFOOD SERVICE EQUIPMENT SUCH AS COMPRESSOR RACKS, EXHAUST AND MAKE-UPAIR SYSTEMS, AIR CONDITIONING, ETC., PRIOR TO BEGINNING CONSTRUCTION.

20 ROOF JACKS AND PENETRATIONS THROUGH ROOF ARE REQUIRED FORREFRIGERATION LINES. SEE ARCHITECTURAL PLANS FOR DETAILS. (VERIFYLOCATION WITH REFRIGERATION CONTRACTOR)

21 INTENDED ENVIRONMENT FOR REFRIGERATED GLASS FRONT & OPEN FRONTDISPLAY CASE, INCLUDING GLASS DOORS ON WALK-IN REFRIGERTORS ANDFREEZERS IS 75ºF/55% RELATIVE HUMIDITY.

22 FOOD SERVICE FACILITIES REQUIRE A DESIGNATED HOT WATER SUPPLY FORFOODHANDLING AREAS, WAREWASHING AREAS, JANITOR SINKS AND EMPLOYEERESTROOMS. PLUMBING DRAWINGS.

23 HOT WATER SUPPLY TO POT AND PREPARATION SINKS SHALL BE 120 DEGREESMINIMUM. HOT WATER SUPPLY TO ALL DISH MACHINES SHALL BE 140 DEGREESMINIMUM.

24 ALL MATERIALS FOR FLOORS, WALLS, AND CEILINGS SHALL BE INSTALLED PERMANUFACTURER’S INSTRUCTIONS.

25 COUNTERS ARE TO BE FABRICATED PROPERLY TO SUPPORT THE SPECIFIEDCOUNTER TOP MATERIAL IN ACCORDANCE WITH THE MATERIAL MANUFACTURER’SGUIDELINES.

26 ALL “DROP-IN” EQUIPMENT AND OTHER EQUIPMENT “ATTACHED TO”, “SET ON”, OR“BUILT-IN” TO THE COUNTERTOP MATERIAL IS TO BE INSTALLED IN ACCORDANCEWITH THE MATERIAL MANUFACTURER’S GUIDELINES AND TECHNICAL BULLETINS FORTHE INSTALLATION OF COMMERCIAL FOOD SERVICE EQUIPMENT.

ENVIRONMENTAL NOTES

1 ALL FOOD-RELATED AND UTENSIL RELATED EQUIPMENT SHALL BEAR THE ANSI/NSFEMBLEM AND/OR BE MANUFACTURED OR FABRICATED IN ACCORDANCE WITHAPPROPRIATE ANSI/NSF STANDARD. SPECIFICALLY STANDARD 2 AND FOR ALLREFRIGERATED EQUIPMENT STANDARD 7.

2 FLOORS IN FOOD PREPARATION, FOOD STORAGE, WAREWASHING, JANITORIAL,HANDWASHING AND TOILET AREAS SHALL BE SMOOTH AND IMPERVIOUS TO WATER,GREASE, AND ACID AND OF EASILY CLEANABLE CONSTRUCTION WITH 6”CONTINUOUS SELF-COVED BASE WITH 3/8” RADIUS. WHERE EQUIPMENT ISINSTALLED ON A CURB, SELF-COVED BASE IS TO EXTEND 4”.

3 AT EXTERIOR TRASH HOLDING AREAS, A CONCRETE SLAB MUST BE PROVIDED FORTRASH , GARBAGE AND GREASE CONTAINERS. IF WALLS ENCLOSE THE AREA, THEINTERIOR WALL SURFACES ARE TO BE SMOOTH, SEALED AND WASHABLE (E.G.PLASATERED SMOOTH AND PAINTED, ETC.)

4 ALL FLOOR MOUNTED EQUIPMENT WILL BE INSTALLED ON MINIMUM 6” SANITARYLEGS, CASTERS OR COMPLETELY SEALED IN POSITION ON A 4” HIGH CURB WITHCONTINUOUSLY COVED BASE. COUNTER TOP EQUIPMENT SHALL BE MOUNTED ON 4”SANITARY LEGS OR SEALED TO THE COUNTER UNLESS READILY MOVEABLE.

5 ALL REFRIGERATION EQUIPMENT SHALL HAVE A THERMOMETER WHICH IS EASILYREADABLE AND IN PROPER WORKING CONDITION.

6 WALLS IN FOOD PREPARATION AREAS AND DISHWASHING AREAS SHALL BE SMOOTHAND NON-ABSORBENT WITH A LIGHT COLORED, EASILY CLEANABLE FINISH. ALLPAINTED SURFACES SHALL BE SEALED WITH A GLOSS OR SEMI-GLOSS ENAMEL.

7 CEILINGS IN KITCHEN PREPARATION AREAS SHALL BE SMOOTH ANDNON-ABSORBENT WITH A LIGHT COLORED, EASILY CLEANABLE FINISH. ALL PAINTEDSURFACES SHALL BE SEALED WITH A GLOSS OR SEMI-GLOSS FINISH.

8 LAVATORY (HANDWASHING) SINKS SHALL BE PROVIDED IN THE FOOD PREPARATION,FOOD SERVING AND WAREWASHING AREAS. SOAP AND SANITARY TOWELS SHALL BEPROVIDED IN SINGLE SERVICE, PERMANENTLY INSTALLED DISPENSERS AT THELAVATORY SINKS. ALL HANDWASHING SINKS SHALL HAVE A COMBINATION FAUCETOR PREMIXING FAUCET CAPABLE OF SUPPLYING WATER TEMPERED TO 100 F TO 108F AND BE SELF CLOSING OR METERED TO PROVIDE TO PROVIDE AT LEAST 15SECOND OF WATER WITHOUT REACTIVATION.

9 TOILET FACILITIES SHALL BE PROVIDED WITHIN EACH FOOD ESTABLISHMENTCONVENIENT FOR THE EMPLOYEES.

10 ALL TOILET ROOMS, JANITOR CLOSETS WITH JANITOR SINKS, INDOOR TRASH ROOMSAND DRESSING/CHANGE ROOMS SHALL BE PROVIDED WITH MECHANICALVENTILATION, LIGHTS AND SWITCHES CONSISTENT WITH MECHANICAL CODEREQUIREMENTS.

11 ALL EXTERIOR DOORS SHALL OPEN OUTWARD AND BE SELF-CLOSING ANDTIGHT-FITTING. BI-FOLD, FRENCH, ACCORDIAON STYLE AND ROLL-UP DOORSCANNOT OPEN INTO FOOD PREPARATION, UNPACKAGED FOOD SERVICE ORWAREWASHING AREA.

12 TOILET ROOM DOORS ARE TO BE SELF-CLOSING AND TIGHT- FITTING.

13 ALL PLUMBING, ELECTRICAL AND GAS LINES SHALL BE CONCEALED WITHIN THEBUILDING STRUCTURE TO AS GREAT AN EXTENT AS POSSIBLE. ALL EXPOSEDCONDUIT, PLUBMING LINES, ETC. SHALL BE INSTALLED A MINIMUM OF 6” ABOVE THEFLOOR AND ¾” FROM THE WALLS USING STANDOFF EASILY CLEANABLE BRACKETS.

14 UTENSIL SINKS TO HAVE 3 COMPARTMENTS THAT ARE A MINIMUM SIZE OF 18” X 18” X12” DEEP WITH A MINIMUM 18” DRAINBOARD AT EACH END. IF THE END IS AGAINST AWALL, THE END MUST HAVE AN 8” INTEGRAL BACKSPLASH. THE SINK TUB MUST BECAPABLE OF ACCOMMODATING THE LARGEST UTENSIL TO BE WASHED.

15 PREP SINK COMPARTMENTS MUST BE AT LEAST 18” X 18” X 12” DEEP WITH A MINIMUMDRAINBOARD OF 18”.

16 FAUCETS SHALL HAVE SPOUTS CAPABLE OF REACHING EACH SINK COMPARTMENT

17 APPROVED BACKFLOW PREVENTION DEVICES SHALL BE PROPERLY INSTALLEDUPSTREAM OF ANY POTENTIAL HAZARD BETWEEN THE POTABLE WATER SUPPLY ANDA SOURCE OF CONTAMINATION. HOSES SHALL NOT BE ATTACHED TO A FAUCET ORHOSE BIBB UNLESS AN APPROVED BACKFLOW PREVENTER IS SUPPLIED.

18 IN EVERY ROOM AND AREA IN WHICH ANY FOOD IS PREPARED, MANUFACTUERED,PROCESSED, OR PREPACKAGED OR IN WHICH EQUIPMENT OR UTENSILS ARECLEANED, SUFFICIENT NATURAL OR ARTIFICIAL LIGHTING SHALL BE PROVIDED TOPRODUCE LIGHT INTENSITY, WHILE THE AREA IS IN USE:

A)AT LEAST 10-FOOT CANDLES FOR THE FOLLOWING: 1)AT A DISTANCE OF 30 INCHES ABOVE THE FLOOR, IN WALK-IN

REFRIGERATION UNITS AND DRY FOOD STORAGE UNITS. 2)AT A WORKING SURFACE ON WHICH ALCOHOLIC BEVERAGES ARE

PREPARED OR WHERE UTENSILS USED IN THE PREPARATION OR SERVICE OF ALCOHOLIC BEVERAGES ARE CLEANED.

3)INSIDE EQUIPMENT SUCH AS REACH-IN OR UNDER THE COUNTER REFRIGERATORS.

B)AT LEAST 20-FOOT CANDLES FOR THE FOLLOWING: 1)AT A SURFACE WHERE FOOD IS PROVIDED FOR CONSUMER

SELF-SERVICE OR WHERE FRESH PRODUCE OR PREPACKAGED FOODS ARE SOLD OR OFFERED FOR CONSUMPTION.

2)IN SERVER STATIONS WHERE FOOD IS PREPARED. 3)AT A DISTANCE OF 30 INCHES ABOVE THE FLOOR IN AREAS

USED FOR HANDWASHING, WAREWASHING, EQUIPMENT AND UTENSIL STORAGE AND IN TOILET ROOMS.

4)IN ALL AREAS AND ROOMS DURING PERIODS OF CLEANING.

C)EXCEPT IN SERVER STATOINS WHERE FOOD IS PREPARED, AT LEAST 50-FOOT CANDLES AT A SURFACE WHERE A FOOD EMPLOYEE IS WORKING WITH FOOD OR WORKING WITH UTENSILS OR EQUIPMENT SUCH AS KNIVES, SLICERS, GRINDERS OR SAWS WHERE EMPLOYEE SAFETY IS A FACTOR.

ABBREVIATIONS

(N) NEW

* SEE REMARKS COLUMN

A AMPS

A.F.F. ABOVE FINISH FLOOR

A.G.A. AMERICAN GAS ASSOCIATION

AL ALUMINUM

ALT ALTERNATE

APPROX APPROXIMATE

ARCH ARCHITECTURAL

BLDG BUILDING

C CONVENIENCE OUTLET

C.W. COLD WATER

CLR CLEAR

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONTR CONTRACTOR

D DIRECT CONNECTION

D.F.A. DOWN FROM ABOVE

DCO DUPLEX CONVENIENCE OUTLET

DIA DIAMETER

DIM DIMENSION

DWG DRAWING

EA EACH

EH EXHAUST

ELEC ELECTRICAL, ELECTRIC

EQ EQUAL

EQUIP EQUIPMENT

EXIST EXISTING

F.S. FLOOR SINK

FD FLOOR DRAIN

FLR FLOOR

FSEC FOOD SERVICE EQUIPMENT CONTRACTOR

FT FOOT

G.C. GENERAL CONTRACTOR

GA GUAGE

GALV GALVANIZED

GL GLASS

GPH GALLONS PER HOUR

GYP. BD. GYPSUM BOARD

H.W. HOT WATER

HP HORSEPOWER

HT HEIGHT

HTR HEATER

I.D. INTERIOR DIMENSION, INTERIOR DIAMETER

IN INCH

JAN JANITOR

KEC KITCHEN EQUIPMENT CONTRACTOR

KW KILOWATT

L LENGTH

MAX MAXIMUM

MECH MECHANICAL

MED MEDIUM

MFG MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

N.I.C. NOT IN CONTRACT

NIFSEC NOT IN FOOD SERVICE EQUIPMENT CONTRACT

O.C. ON CENTER

O.D. OVERALL DIMENSION, OUTSIDE DIAMETER

P.S.I. POUNDS PER SQUARE INCH

PLY PLYWOOD

PT PAINT

R RADIUS, RAFTER

REQ REQUIRED

REQ'S. REQUIREMENTS

RM ROOM

SECT SECTION

SHT SHEET

SOV SHUT-OFF VALVE

SQ SQUARE

ST. STL. STAINLESS STEEL

STD STANDARD

STRUCT STRUCTURAL

T TEE

THK THICK

TYP TYPICAL

W WIDE, WIDTH, WASTE

W/ WITH

WD WOOD

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 141 OF

2154

2160

2136

K

2148

18

60

18

60

1842

18

60

18

60

2160

2136

2136

2136

2154

T

F

4

8

8

7

6

5

5

WAREWASHING PREP

COOKLINEPREP

SERVICE COUNTER

WALK-INCOOLER

WALK-INFREEZER

DRY STORAGE

JAN.

CATERING

2448

11

11

7

12

13

14

15

3331

27 25 5

24

2223

4445

4647515253465456

57

626361

646665

67

32 26

5

5

6

33

74

REMOTE REFRIGERATION RACK,VERIFY WITH ARCH. DRAWINGSFOR ACTUAL LOCATION. CONDUITLINES SHOWN ON SHEET QF-501ARE FOR SCHEMATIC PURPOSESONLY.

41

35

36

7169 70

17

2 2 2

1

16

16

2

2

222

22

37

3430

72

2

2

43

42

75QF-701

1

QF-701

2

3

QF-701

4

QF-7015 QF-701

6

7

QF-702 1

QF-702

2

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:4

6 P

M

1/4

" =

1'-0

"

EQ

UIP

ME

NT

FLO

OR

PLA

N

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

11/2

5/14

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-101

Aut

hor

16 J

ULY

201

5

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 142 OF

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:4

8 P

M

EQ

UIP

ME

NT

SC

HE

DU

LE

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

03/2

2/12

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-201

Aut

hor

16 J

ULY

201

5

FOODSERVICE EQUIPMENT SCHEDULE 1

ITE

M N

UM

BE

R

QU

AN

TIT

Y

DESCRIPTION SOURCE HO

T

CO

LD

CO

NN

. S

IZE

MB

TU

WA

ST

E

MECHANICAL REMARKS VO

LT

AG

E

KW

AM

PS

HP

PH

AS

E

CO

NN

.

ELECTRICAL REMARKS

1 WORK TABLE W/ PREPSINK

CUSTOMST.STL.

F.S. 120 6.0 1 C 6 LOCATIONS

1 1 AIR CURTAINS MARS N42-1U 120 5.1 1 D WIRE THROUGH DOOR ACTIVATED MICRO-SWITCH

2 13 BUMPER RAIL CUSTOMST. STL.

3 1 SPARE #

4 1 SPARE #

5 3 TRASH RECEPTACLE NIFSEC - REFERTO FF&E PACKAGE

6 1 WORK TABLE W/ PREPSINK

CUSTOMST.STL.

F.S. 120 6.0 1 C 6 LOCATIONS

7 1 SPLASH MOUNTEDFAUCETS

T&SB-0231-CR

1/2" 1/2"

8 1 SPARE #

9 1 SPARE #

10 1 SPARE #

11 4 MOBILE WORK TABLES ADVANCE TABCOSS-304

12 1 WATER FILTRATIONSYSTEM

SCOTSMANSSM2-P

1/2" INTERCONNECT C.W. WITH ICE MAKER

13 1 AIR COOLED ICE MAKER SCOTSMANC1030SA-32

* F.S. FILTERED C.W. FROM WATER FILTER ITEM#12

208 16.0 1 D

14 1 ICE STORAGE BIN SCOTSMANB948S

F.S.

15 1 FLOOR TROUGH CUSTOMST. STL.

3" "P-TRAP" BELOW SLAB

16 12 DRY STORAGE SHELVINGUNITS (CAMBRO)

NIFSEC - REFERTO FF&E PACKAGE

17 1 BUILK CO2 AND SODASYSTEM

NIFSECBY VENDOR

1/2" F.S. VERIFY REQUIREMENTS WITH SUPPLIER.DRAIN TO FLOOR SINK

120 6.0 1 C VERIFY REQUIREMENTS WITH SUPPLIER

18 1 SPARE #

19 1 SPARE #

20 1 SPARE #

21 1 SPARE #

22 1 HAND SINK W/SOAP ANDTOWEL DISPENSER

IMC TEDDYADA-WSX

2"

23 1 HAND SINK FAUCETS T&SB-0325-CR

1/2" 1/2"

24 1 FIRE PROTECTIONSYSTEM SERVES ITEM#56

ANSULR102

CONTRACTOR TO INSTALL GAS SHUT-OFFVALVE IN ACCESSIBLE CEILING SPACE.

120 6.0 1 D SEE SHEET QF-602 FOR ADDITIONAL INFORMATION.

25 1 SPLASH MOUNTEDFAUCETS

T&SB-0231-CR

1/2" 1/2"

26 1 WALL SHELF(KNIFE BRACKETS)

CUSTOMST. STL.

27 1 WORK TABLE W/ PREPSINK

CUSTOMST. STL.

F.S. 120 6.0 1 C

28 1 SPARE #

29 1 SPARE #

30 1 UNDERCOUNTERDISHMACHINE

MEIKOFV 40.2

3/4" F.S. INDIRECT WASTE TO FLOOR SINK 208 32.1 3 D

31 1 POT STORAGE SHELVINGUNITS (CAMBRO)

NIFSEC - REFERTO FF&E PACKAGE

32 1 UTENSIL RACK CUSTOMST.STL.

33 2 SPLASH MOUNTEDFAUCETS

T&SB-0291

3/4" 3/4" PER UNIT REQUIREMENTS

34 1 3 COMPARTMENT SINK CUSTOMST.STL.

2"F.S.

PER LOCAL CODES

35 1 WALK-IN FREEZER(REMOTE)

THERMALRITECUSTOM

120 -- 1 D WIRE THRU LIGHTS, AND SWITCH.

36 1 BLOWER COIL (REMOTE) THERMALRITE F.S. * * * * * * SEE SHEET QF-501 FOR ELECTRICAL REQUIREMENTS,AND ADDITIONAL INFORMATION.

37 3 FREEZER SHELVING UNITS(CAMBRO)

NIFSEC - REFERTO FF&E PACKAGE

38 1 SPARE #

39 1 SPARE #

40 1 SPARE #

41 1 WALK-IN REFRIGERATOR(REMOTE)

THERMALRITEPART OF ITEM #35

120 -- 1 D WIRE THRU LIGHTS, AND SWITCH.

42 1 BLOWER COIL (REMOTE) THERMALRITE F.S. * * * * * * SEE SHEET QF-501 FOR ELECTRICAL REQUIREMENTS,AND ADDITIONAL INFORMATION.

43 2 REFRIGERATED SHELVINGUNITS (CAMBRO)

NIFSEC - REFERTO FF&E PACKAGE

44 1 FIRE PULL BOX PART OF ITEM# 24 * * * * * * CONTRACTOR TO INSTALL 4/0 BOX AT +48" A.F.F. SEESHEET QF-602 FOR ADD. INFO.

45 1 CLASS KFIRE EXTINGUISHERS

SEE ARCHITECTSECTION

46 2 SPREADER CABINET MONTAGUE24-S

1" * INTERCONNECT GAS WITH ITEM #'S 47, 52,53

47 1 4 O.B. COUNTER-TOPRANGE

MONTAGUEC24-5

* 120 * INTERCONNECT GAS WITH ITEM # 46

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 143 OF

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:4

8 P

M

EQ

UIP

ME

NT

SC

HE

DU

LE

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

09/2

9/14

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-202

Aut

hor

16 J

ULY

201

5

FOODSERVICE EQUIPMENT SCHEDULE 2

ITE

M N

UM

BE

R

QU

AN

TIT

Y

DESCRIPTION SOURCE HO

T

CO

LD

CO

NN

. S

IZE

MB

TU

WA

ST

E

MECHANICAL REMARKS VO

LT

AG

E

KW

AM

PS

HP

PH

AS

E

CO

NN

.

ELECTRICAL REMARKS

48 1 SPARE #

49 1 SPARE #

50 1 SPARE #

51 1 REFRIGERATED STAND(SELF CONTAINED)

MONTAGUERB-96-SC

F.S. 120 8.4 1 C

52 1 COUNTERTOP GRIGGLE MONTAGUEC36-8T

* 80 INTERCONNECT GAS WITH ITEM #46

53 1 COUNTERTOP RADIENTBROILER

MONTAGUEUFLC-36R

* 114 INTERCONNECT GAS WITH ITEM #46

54 1 FRYER ASSEMBLY PITCO2-SSH55R-SSTC-S/FD

1" 200 INTERCONNECT GAS BETWEEN UNITS 120120

7.01.7

11

CC

PUMP AND FILTERCONTROLS

55 1 SPARE #

56 1 EXHAUST HOOD (TYPE 1) ACCUREX*

120 -- 1 D WIRE THRU LIGHTS AND SWITCH. SEE SHEET QF-602FOR ADDITIONAL INFORMATION.

57 1 HOOD TRIM AND CLOSUREPANELS

CUSTOMST.STL.

58 1 SPARE #

59 1 SPARE #

60 1 SPARE #

61 1 WALL SHELFCONCEALED BRACKETS

CUSTOMST. STL.

62 1 WORK COUNTER W/HANDSINK

CUSTOMST.STL.

2" 120 6.0 1 C

63 1 HAND SINK FAUCETS T&SB-0325-CR

1/2" 1/2"

64 1 CASH REGISTER NIFSECBY OWNER

120 6.0 1 C DATA LINE REQUIRED. VERIFY REQUIREMENTSWITH SUPPLIER.

65 1 U.C. REFRIGERATOR(SELF CONTAINED)

BEV AIRUCR46A

120 6.3 1 C NEMA 5-15P WIRE TO FIXTURE MOUNTED OUTLET

66 1 U.C. HEATED CABINET ALTO-SHAAM750-S

120 8.0 1 C WIRE TO FIXTURE MOUNTED OUTLET

67 1 SERVICE COUNTERCABINET BASE

CUSTOMST. STL./MILLWORK

120 6.0 1 C FIXTURE MOUNTED DCO

68 1 SPARE #

69 1 BEER TOWER (4 TAPS) NIFSECFUTURE

120 6.0 1 C VERIFY REQ'S W/ SUPPLIER

70 1 UNDERCOUNTER KEGREFRIGERATOR

NIFSECFUTURE

120 6.5 1 C VERIFY REQ'S W/ SUPPLIER

71 1 SODA AND ICE DISPENSER NICBY VENDOR

1/2" F.S. 120 7.0 1 C VERIFY REQ'S W/ SUPPLIER

72 1 SOUP WELL NIFSEC - REFERTO FF&E PACKAGE

120 9.2 1 C NEMA 5-15P

74 1 WALK-IN FREEZERCONDENSING UNIT

THERMALRITEPART OF ITEM #35

SEE ARCH. DRAWINGS FOR LOCATION -- -- 3 D SEE SHEET QF-501 FOR ADDITIONAL INFO.

75 1 WALK-IN COOLERCONDENSING UNIT

THERMALRITEPART OF ITEM #41

SEE ARCH. DRAWINGS FOR LOCATION -- -- 3 D SEE SHEET QF-501 FOR ADDITIONAL INFO.

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 144 OF

2154

2160

2136

K

2148

18

60

18

60

1842

18

60

18

60

2160

2136

2136

2136

2154

E

F

4 6

5

5

* **475253

6

7

12

13

15

13

14

+14"

+60"

3'-3" 9"9"9" 14'-4" 4'-5" 2'-7"

22

2327

25

WA

TE

R@

+22"

WA

ST

E@

+20"

+14"

+14"

+14"

+12"

3333

34 34

9'-3" 11'-2" 1'-3"1'-9"

+28"

54

+12"

WA

TE

R@

+22"

WA

ST

E@

+20"

ALL GAS SHUT-OFF VALVESSUPPLIED BY THE FOODSERVICEEQUIPMENT CONTRACTOR,INSTALLED IN ACCESIBLE CEILINGSPACE BY PLUMBER. (VERIFYLOCATION)

M

1'-10"

2'-8"

2'-8"

1'-8"1

'-10"

17+14"

17

30

30

30

42

36

7"

36

42

46 47 52 53

1'-9" 51

6263

+14"

1'-7" 2'-4"

6"

1'-4"

1'-3"

1'-6"

71

71

1'-3"

+14"

3'-8"

2"

69

3'-5"

2"

PLUMBING SYMBOLS

HOT WATER DEMAND

HAND SINKS

EQUIPMENT GPH

5

FOOD PREPARATION SINKS 5

UTENSIL SINKS 18"X18" 14

UTENSIL SINKS 24"X24" 25

12"X12" FLOOR SINK

12"X12" FLOOR SINKWITH HALF GRATE

ITEM NUMBER

GAS SHUT-OFF VALVE

DIRECT WASTE

COLD WATER

HOT WATER

GAS

GAS/WATER MANIFOLD CONNECTION

M

1

*

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:5

0 P

M

As

indi

cate

d

PLU

MB

ING

PLA

N

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HX

XX

XX

X

01-0

1-06

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-301

XX

X

16 J

ULY

201

5

PLUMBING NOTES

1 CONTRACTOR TO VERIFY ALL INCOMINGSERVICES AND MAKE ALL EXTERNAL ANDINTERNAL CONNECTIONS. CONTRACTOR TOPROVIDE ALL PIPING, FITTINGS, PARTS, ETC.,NECESSARY TO MAKE EQUIPMENTFUNCTIONAL.

2 CONTRACTOR TO PROVIDE AND INSTALLINDIVIDUAL SHUT-OFF VALVES ON ALLWATER AND GAS LINES.

3 WALL, FLOOR AND WALL PENETRATIONSMUST BE SEALED WATER-TIGHT AND VERMINPROOF.

4 ALL PLUMBING OUTLETS AND CONNECTIONSSHOWN ARE FOR EQUIPMENT SHOWN ONFOOD SERVICE EQUIPMENT PLAN ONLY. (SEEARCHITECTURAL PLANS FOR FURTHERPLUMBING REQUIREMENTS).

5 ALL HORIZONTAL DIMENSIONS SHOWN AREFROM FINISHED FACE ON WALL TOCENTERLINE OF STUB OUT OR FROMCENTERLINE OF STUB OUT TO CENTERLINEOF STUB OUT UNLESS OTHERWISE NOTEDON PLANS OR DETAILS (VERIFY ALLDIMENSIONS AT JOB SITE).

6 ALL SYMBOLS NOTED +12", +24", ETC., ARE TOSTUB OUT OF WALL AT HEIGHT INDICATED.

7 HEIGHT IS GIVEN FROM FINISHED FLOOR(NOT FINISHED CURB) TO CENTERLINE OFSTUB OUT. ALL SYMBOLS NOTED STUB UPARE TO STUB UP ABOVE FINISHED FLOOR ORFINISHED CURB AT LOCATION INDICATED ONPLAN.(VERIFY ALL DIMENSIONS AT JOB SITE)

8 ALL FLOOR SINKS SHOWN ARE TO BE SETFLUSH WITH FINISHED FLOOR. VERIFYLOCATION OF FLOOR SINKS PRIOR TO FINALPOUR. (VERIFY WITH FOOD SERVICEEQUIPMENT CONTRACTOR.)

9 CONTRACTOR TO PROVIDE AND INSTALLREMOVABLE GRILLS OR COVERS FOR ALLFULL OR PARTIALLY EXPOSED FLOOR SINKS.

10 CONTRACTOR TO PROVIDE AND INSTALLTYPE "L" COPPER TUBING DRAIN LINES FROMALL APPLICABLE EQUIPMENT TO FLOORSINKS, (INCLUDING WALK-IN COOLER ANDFREEZER COILS) AND TO INSULATE ALLDRAIN LINES FROM ICE BINS,REFRIGERATION EQUIPMENT ETC..CONTRACTOR TO INSTALL DRAIN LINES SOTHEY DO NOT AFFECT UNDER- COUNTERSTORAGE AND OTHER OPERATIONALFUNCTIONS OF THE FIXTURES.

11 DRAIN FOR DISHWASHER TO HAVE AMINIMUM 3" DRAIN PIPE.

12 CONTRACTOR TO VERIFY ALL INCOMINGWATER TEMPERATURES, GPM'S WITHDISHWASHER SPECIFICATIONS.

13 IF INLET PRESSURE ON HOT WATER LINE ISIN EXCESS OF 25 LBS. FLOW PRESSURE,CONTRACTOR TO PROVIDE AND INSTALLPRESSURE REGULATING VALVE. G.P.H. RINSECONSUMPTION AT 25 LBS. FLOW PRESSUREREQUIRED FOR DISH WASHING MACHINE.

14 CONTRACTOR TO INSTALL AND FOODSERVICE EQUIPMENT CONTRACTOR TOPROVIDE, AUTOMATIC SHUT-OFF VALVE(S) INGAS LINE FOR FIRE SUPPRESSION SYSTEM INHOOD.

15 CONTRACTOR TO PROVIDE AND INSTALLSTRAINERS OR APPROVED TYPE FILTERS ONGAS SUPPLY LINES.

16 CONTRACTOR TO INSTALL AND FOODSERVICE EQUIPMENT CONTRACTOR TOPROVIDE, ALL GAS PRESSURE REGULATINGVALVES.

17 CONTRACTOR TO PROVIDE AND INSTALLBACK FLOW PREVENTION DEVICES FORFIXTURES AS REQUIRED BY LOCALPLUMBING AND BUILDING DEPARTMENTS.

18 THIS PLAN IS FOR PLUMBING REQUIREMENTSFOR SPECIFIC FOOD SERVICE AREAS ONLY.CONTRACTOR TO REFER TO ARCHITECTURALDRAWINGS FOR ADDITIONAL PLUMBINGREQUIREMENTS NOT SHOWN.

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 145 OF

2154

2160

2136

K

2148

18

60

18

60

1842

18

60

18

60

2160

2136

2136

2136

2154

J

J

JJ

J

J

J

J

1'-4"

7"

1

D.F

.A.

2'-9"

4'-9"

6'-7" 6'-10" 3'-6"

6

6

666

+50"

+50"

+50"

+50"

+50"

8"

5'-0"

13

6+50"

+60"

2'-5"

17+72"

1'-8" 16'-1" 6'-7"

242730

+60"

+60"

+60"

36

42

35

41

1'-7"1'-7"

5'-1"

1'-9"

36

42

41

35

44

+48"

2'-3" 5'-4" 2'-1" 2'-0" 8'-8"

+60"

+60"

+60"

+60"

D.F

.A.

625454

5156

2'-3"

ON ROOF-VERIFYLOC'N. W/ ARCH

74

2'-10" 2'-11" 3'-8" 2'-11" 4'-6" 3'-11"

+18"

+18"

+18"

+18"

+18"

+18"

71

64 65 66 70 67

72

F

G

J

14

ON ROOF-VERIFYLOC'N. W/ ARCH

75

+60"

* FINAL CONNECTION POINT

ELECTRICAL SYMBOLS

F

S

J

4/0 FIRE PULL BOX

FLEX CONNECTION

ITEM NUMBER

HEATING ELEMENT

SWITCH

TELEPHONE/ DATA

FIXTURE MOUNTED DOUBLE CONV OUTLET

JUNCTION BOX STUB UP / STUB DOWN

120 VOLT DOUBLE CONV OUTLET

5 COLOR COATED DEFROST CONTROL WIRES(FROM BLOWER COIL TO CONDENSING UNIT, TIMECLOCK BY ELECTRICIAN.)

208 VOLT SINGLE CONV OUTLET

MOTOR

JUNCTION BOX

DOWN FROM ABOVED.F.A.

1

J

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:5

1 P

M

As

indi

cate

d

ELE

CT

RIC

AL

PLA

N

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

03/2

6/12

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-401

Aut

hor

16 J

ULY

201

5

ELECTRICAL NOTES

8 CONTRACTOR TO PROVIDE A MINIMUM OF 3 WIRES ONALL 208 OR 230 VOLT CIRCUITS.

9 CONTRACTOR TO RUN IN CONDUIT - A 5 WIRE CIRCUITFROM REFRIGERATION RACK TO EVAPORATOR COIL FORAUTOMATIC DEFROST HOOK-UP ON REMOTE FREEZERCABINETS.

10 CONTRACTOR TO PROVIDE AND INSTALL SERVICE ONROOF FOR EXHAUST AND MAKE-UP AIR SYSTEMS PERMECHANICAL ENGINEER DRAWINGS. (VERIFY LOCATION).

11 CONTRACTOR TO PROVIDE AND INSTALL UNDERBARLIGHTING AND CONNECT BACKBAR DISPLAY LIGHTINGPROVIDED BY THE FOOD SERVICE EQUIPMENTCONTRACTOR.

12 CONTRACTOR TO PROVIDE AND INSTALL STAINLESSSTEEL COVER PLATES FOR ALL RECEPTACLES ANDSWITCHES IN FOOD PREPARATION AREAS UNLESSOTHERWISE NOTED. ALL RECEPTACLES TO BE SETHORIZONTALLY.

13 CONTRACTOR TO PROVIDE AND INSTALL ALL GENERALLIGHTING FIXTURES COMPLETE WITH LAMPS.DECORATIVE LIGHT FIXTURES THAT ARE SUPPLIED BYTHE FOOD SERVICE EQUIPMENT CONTRACTOR ARE TOBE INSTALLED BY THE ELECTRICAL CONTRACTOR WITHLAMPS BY OWNER, UNLESS OTHERWISE NOTED.

14 CONTRACTOR TO PROVIDE AND INSTALL EXIT LIGHTSUNLESS OTHERWISE NOTED. REFER TO ARCHITECTURALAND ELECTRICAL ENGINEERS DRAWINGS.

15 CONTRACTOR TO PROVIDE CAPS AND CORDS FOR ALLITEMS WHICH USE CONVENIENCE OUTLETS WHEN NOTSUPPLIED BY THE MANUFACTURER AND SHORTEN ANYCORDS IF NECESSARY OR REQUESTED.

16 CONTRACTOR TO INSTALL FLY FAN(S) AND/OR AIRCURTAINS PROVIDED BY THE FOOD SERVICE EQUIPMENTCONTRACTOR, UNLESS OTHERWISE NOTED.

17 CONTRACTOR TO PROVIDE AND INSTALL MECHANICALVENTILATION WITH LIGHT AND SWITCH IN RESTROOMSAND CHANGE ROOMS(MINIMUM AIR CHANGE = 12 PERHOUR.)

18 FIXTURE FABRICATOR SHALL CUT ACCESS HOLES TOCONVENIENCE OUTLETS IN BACK SPLASHES, ETC.,CONTRACTOR TO PROVIDE EXTENSION SHIELDS IFREQUIRED.

19 CONTRACTOR TO PROVIDE AND INSTALL ALL WIRING FORWALK-IN COOLERS AND FREEZERS ON THE EXTERIOR OFTHE BOX WHERE POSSIBLE.

20 CONTRACTOR TO VERIFY ALL DIMENSIONS AT THE JOBSITE.

21 CONTRACTOR TO VERIFY ANY ADDITIONAL ELECTRICALSERVICES REQUIRED ELSEWHERE IN THE BUILDING FORITEMS NOT SHOWN ON THE PLANS, AND FOR N.I.F.S.E.C.ITEMS.

22 CONTRACTOR TO VERIFY TYPE OF CONDUIT THAT MEETSLOCAL BUILDING AND ELECTRICAL CODES.

23 CONTRACTOR TO VERIFY ALL WIRING OF WALK-INCOOLERS / FREEZERS WITH CONTRACTOR PRIOR TOINSTALL.

24 CONTRACTOR TO CONNECT ALL EXHAUST AND MAKE-UPAIR FANS AND SUPPLY PER MECHANICAL ENGINEERDRAWINGS.

25 CONTRACTOR TO INTERCONNECT EXHAUST ANDMAKE-UP AIR FANS AND/OR DEMAND CONTROLVENTILATION SYSTEMS PER MECHANICAL ENGINEERDRAWINGS.

26 CONTRACTOR TO PROVIDE SERVICE FOR SOUNDSYSTEMS, P.O.S. SYSTEMS AND TELEPHONES.

27 CONTRACTOR TO HOOK-UP HEATER STRIPS AT COLDSTORAGE ROOM DOORS AND DRAIN LINES AS REQUIRED.

ELECTRICAL NOTES

1 CONTRACTOR TO VERIFY ALL INCOMING SERVICE ANDPROVIDE FINAL HOOK-UP TO ALL APPLICABLEEQUIPMENT. CONTRACTOR TO PROVIDE ALL SWITCHES,BREAKERS, CONDUIT, ETC., UNLESS SPECIALLY STATEDOTHERWISE.

2 CONTRACTOR TO PROVIDE ALL JUNCTION BOXES,OUTLETS AND RECEPTACLES IN FIXTURES. FIXTUREFABRICATOR TO LOCATE ALL RECEPTACLES ANDSWITCHES WHEN PART OF FIXTURE. INTERNAL WIRINGTO BE PROVIDED AND INSTALLED BY CONTRACTOR.

3 ALL ELECTRICAL OUTLETS AND CONNECTIONS SHOWNON THE PLAN ARE FOR EQUIPMENT SHOWN ON FOODSERVICE EQUIPMENT PLAN (SEE ARCHITECTURAL PLANSFOR ADDITIONAL ELECTRICAL REQUIREMENTS.)

4 ALL HORIZONTAL DIMENSIONS SHOWN ARE FROMFINISHED FACE OF WALL TO CENTERLINE OF OUTLETUNLESS OTHERWISE NOTED ON PLANS OR DETAILS.CONTRACTOR TO VERIFY ALL DIMENSIONS AT JOB SITES.ALL SYMBOLS NOTED +12”, +24”, ETC., TO STUB OUT OFWALL AT HEIGHT INDICATED.

5 HEIGHT IS GIVEN FROM FINISHED FLOOR (NOT FINISHEDCURB) TO CENTERLINE OF OUTLET. ALL SYMBOLS NOTED“STUB UP” ARE TO STUB UP ABOVE FINISHED FLOOR ATHEIGHT AND LOCATION INDICATED (MINIMUM HEIGHT TOBE 6” A.F.F.)

6 CONTRACTOR TO PROVIDE 6’-0” PIGTAIL FLEX CONDUITAT ALL DIRECT CONNECT STUB OUTS, EXTEND ANDCONNECT TO FIXTURES.

7 CONTRACTOR TO WIRE MAGNETIC CONTACTORS FORPOWER SHUT-OFF FOR ALL ELECTRIC COOKINGEQUIPMENT THAT IS PROTECTED BY THE FIRESUPPRESSION SYSTEM. CONNECT 115V CONTROLCIRCUIT FROM MICRO-SWITCH SYSTEM ON CYLINDER.MOUNT TO CONTACTOR COIL.

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 146 OF

2154

2160

2136

K

2148

18

60

18

60

1842

18

60

18

60

2160

2136

2136

2136

2154

E

F

4

5

5

REMOTE CONDENSING UNITS ITEM #74, 75 SHOWN FOR SCHEMATICPURPOSES ONLY. VERIFY ACTUALLOCATION WITH ARCHITECT'SDRAWINGS

3

D.F.A.

FROM:ITEM #75

74

3

FROM:ITEM #74

5'-6"

4'-0"

1'-2"

1'-5"

42

36D.F.A.

TO:ITEM #71

4

4'-6"

4"17

+18"71

75

3'-0"

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:5

2 P

M

1/4

" =

1'-0

"

RE

FR

IGE

RA

TIO

N &

CO

ND

UIT

PLA

N

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

03/2

6/12

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-501

Aut

hor

16 J

ULY

201

5

LEGEND

12"X12" PULLBOX W/ 2 CONDUITS

12"X12" PULLBOX W/ 1 CONDUIT

NOTE:

3

4

OVERHEAD REFRIGERATIONLINE RUN THROUGHACCESSIBLE CEILING.

4" DIA. APPROVED CONDUIT-RUN OVERHEAD WITH MINIMUM24" RADIUS BENDS FOR SODASYSTEM SYRUP LINES ININACCESSIBLE SPACES.

CONDUIT LINE RUNS SHOWN AREFOR SCHEMATIC PURPOSES ONLY.ACTUAL RUNS TO BE DETERMINEDBY FIELD CONDITIONS.*PROVIDE PULL BOX EVERY 50 FEET

REFRIGERATION NOTES

1 CONTRACTOR SHALL INSULATE ALLREFRIGERATION LINES WHERE REQUIREDBY CODE.

2 CONTRACTOR SHALL VERIFY LOCATION OFALL REMOTE REFRGERATION SYSTEMCOMPONENTS, INCLUDING EVAPORATORCOILS, REFRIGERATION RACK,COMPRESSORS, CONDENSORS, ETC.

3 CONTRACTOR SHALL VERIFY LOCATION OFPITCH POCKET FOR REFRIGERATION LINEPENETRATION THRU ROOF WITH GENERALCONTRACTOR. GENERAL CONTRACTOR TOINSTALL PITCH POCKETS.

4 GENERAL CONTRACTOR TO BACKFILL PITCHPOCKET TO TOP WITH TAR OR PITCH AFTERREFRIGERATION LINES HAVE BEEN RUN.

5 IF PULLBOX IS SPECIFIED, A MINIMUM 12" X12" MUST BE USED.

6 ALL PENETRATIONS THRU ROOF TO BEPROVIDED BY GENERAL CONTRACTOR.

7 CONTRACTOR TO SEAL ENDS OF CONDUITWITH "FOMOFIL" AFTER ALL REFRIGERATIONLINES HAVE BEEN RUN.

8 A 3'-0" CLEARANCE IS REQUIRED AROUNDTHE PERMITER OF ROOF MOUNTEDREFRIGERATION EQUIPMENT FOR SYSTEMMAINTENANCE.

9 PROPER VENTILATION IS REQUIRED FORINDOOR MOUNTED REFRIGERATIONEQUIPMENT/RACK. SEE REFRIGERATIONSYSTEM DRAWINGS FOR REQUIREMENTS.

10 REFRIGERATION RACK SYSTEMMANUFACTURER TO PROVIDE AND INSTALLALL REQUIRED ELECTRICAL COMPONENTS(FUSED DISCONNECT, TIME CLOCKS,MAGNETIC STARTERS, DRAIN LINEHEATERS, ETC.) AND FACTORY WIRED(CONDUIT AND CABLE) FOR ALL CONTROLSWITHIN THE REFRIGERATION SYSTEM (PERDIVISION 16) TO A SINGLE POINT OFSERVICE FOR POWER CONNECTIONS.REFRIGERATION RACK SHALL BE UL LISTED.CONTRACTOR TO PROVIDE ALL CONDUITAND WIRING BETWEEN REFRIGERATIONRACK AND REMOTELY LOCATED SYSTEMCOMPONENTS.

11 PROVIDE A UTILITY OUTLET (120 VOLT, 800WATTS) FOR SERVICE AND MAINTENANCEOF THE ROOF MOUNTED REFRIGERATIONRACK/EQUIPMENT.

12 ALL SYSTEMS AND COMPONENTS SHALL BELABELED. PROVIDE A COPY OF THEREFRIGERATION PLAN IN AN EASILYACCESSIBLE WEATHER PROTECTED AREA.

13 ICE MACHINE REMOTE CONDENSERCONDUIT RUNS SHALL NOT EXCEED 20FEET VERTICALLY AND 40 FEETHORIZONTALLY.

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 147 OF

2154

2160

2136

K

2148

18

60

18

60

1842

18

60

18

60

2160

2136

2136

2136

2154

E

F

4

8

8

7

6

5

5

FQF-601

3'-10" 1'-9"

GQF-601

FQF-601

FQF-601

FQF-601

FQF-601F

QF-601

BQF-601

5'-1"

6'-3"

5'-8"

1'-11"

3'-1" 1'-6"

FQF-601

FQF-601

FQF-601

3QF-801

FQF-601

FQF-601

FQF-601

2'-5" 6'-6" 5'-7" 6'-1" 1'-8" 2'-6" 2'-6" 1'-5"

CQF-601

DQF-601

AQF-601

EQF-601

AQF-601

1'-0" 10'-4" 11" 13'-9"

17'-8"

NON-COMBUSTIBLE WALL

DQF-601

LOW WALL APPROX. 2'-8" A.F.F.

FREEZERDEPRESSION

SEE SHEET QF-602FOR EXHAUST HOODINFORMATION

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:5

4 P

M

1/4

" =

1'-0

"

BU

ILD

ING

WO

RK

S &

EX

HA

US

T P

LAN

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

03/2

6/12

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-601

Aut

hor

16 J

ULY

201

5

EXHAUST & MAKE-UP

84"

D

30"

WATER FILTERWALL SHELF

46"

A

36"

B C

27"

HAND SINK

21"

HOOD G

16"

AIR CURTAIN

74"

12"

24"

EUTENSIL RACK FBUMPER RAIL

16"

DO

OR

HE

IGH

T

EXHAUST NOTES

3 EXHAUST AND MAKE-UP AIR SYSTEMS MUST BEELECTRICALLY INTERLOCKED FORSIMULTANEOUS OPERATION EXCEPT IN THE CASEOF EMERGENCY AS MANDATED BY THE FIREMARSHALL. REFER TO MECHANICAL ENGINEER'SDRAWINGS AND SPECIFICATIONS FOR DETAILS.

4 MAKE-UP AIR SHALL BE DELIVERED IN THEPROXIMITY OF THE EXHAUST HOOD(S), I.E. WITHIN10 LINEAL FEET, SHALL NOT INCLUDE 4-WAY AIRDIFFUSERS NOR EXCEED 100 FEET PER MINUTEVELOCITY.

5 SEE MECHANICAL ENGINEER'S DRAWINGS FORADDITIONAL INFORMATION REGARDINGCOMPLETE BALANCED EXHAUST AND MAKE-UPAIR SYSTEMS.

EXHAUST NOTES

1 EXHAUST HOOD(S) WITH MECHANICAL EXHAUSTSYSTEM(S) TO BE PROVIDED OVER COOKINGEQUIPMENT. MINIMUM OVERHANG SHALL BE ASREQUIRED BY ALL GOVERNING AGENCIES.PROVIDE OVERHANG IN EXCESS OF MINIMUM ASSHOWN ON DRAWINGS.

2 MECHANICALLY INDUCED MAKE-UP AIR MUST BEPROVIDED FOR COOKING AND DISHWASHINGEXHAUST HOOD(S) IN CONJUINCTION WITH THEH.V.A.C SYSTEMS IN ORDER TO REPLACE 100% OFEXHAUSTED AIR. REFER TO MECHANICALENGINEER'S DRAWINGS AND SPECIFICATIONSFOR DETAILS.

63"

18"

BLDG WORKS NOTES

1 ALL WALL BACKING TO BE 16 GAUGEGALVANIZED METAL SECURELY ATTACHED TOSTUD/WALL FRAMING.

2 WALL BACKING LENGTHS SHOWN ON BUILDINGWORKS PLAN REQUIREMENTS ARE THEMINIMUM. ALWAYS EXTEND WALL BACKING TONEXT STUD OVER IN EACH DIRECTION.

3 ALL WORK SHOWN ON BUILDING WORKS PLANTO BE BY GENERAL CONTRACTOR UNLESSOTHERWISE NOTED.

EXHAUST HOODDUCT CONNECTION

SUPPLY AIR PLENUMCONNECTION

WALLBACKING DETAILS

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 148 OF

VENTILATION SYSTEM NOTES

Accurex ventilators are designed in compliance with all national codes:NFPA # 96, national electric code and IBC, uniform mechanical code,and international mechanical code. See national evaluation report #436for allowable values, and/or conditions of use concerning materialpresented in this document. Local codes may vary. It is theresponsibility of the purchaser to submit drawings to local authorities.

Exhaust and supply air volumes are to be maintained within -5% to+10% tolerance of values indicated. Static pressure(s) indicated are forthe ventilator at the duct connection(s) only.

The grease filter face velocities are based on the filter manufacturersrecommendations for maximum greaseextraction. Inlet opening airvelocities for waterwash, dry cartridge and high velocity cartridge filtersmanufactured by Accurex are designed to deliver maximum greaseextraction.

Hoods installation (by others unless otherwise noted) shall be inaccordance with NFPA # 96 and applicable building codes.

CONSTRUCTION COMPLIES

WITH NFPA 96

RR

GENERAL DRAWING NOTES

Verify building entry conditions or limitations for equipment access tospace.

Verify type and height of finished ceiling and if hood(s) may extendabove finished ceiling (if required).

Seismic installation and bracing of equipment is by others.Accurex will not accept liability for problems that result fromsub-standard installation. Including field electrical wiring that deviatefrom supplied diagrams, jobsite conditions (ductwork, fuel types andstructural conditions) that Accurex has not been notified of at the timeof ordering. Or use of this equipment other than that for which it isdesigned.

It is the responsibility of the purchaser to hire qualified personnel forinstallation and start-up of all equipment. Installation and start-upinformation is shipped with all equipment via the Installation, Operationand Maintenance Manual (IOM), also included is a troubleshootingguide. Have all start-up info available prior to any warranty claimsand/or factory technical support.

PART NO.

CAD DRAWING NO. ECO

REV.

INSULATED DOUBLESHELL FRONT

REMOVABLE GREASE CUP W/CONCEALED GREASE TROUGH

UL LISTED HIGH EFFICIENCY'GREASE-X-TRACTOR' FILTERS

INTEGRAL AIRSPACE

UL LISTED LIGHT FIXTURE

INTERIOR SHELL

PERFORMANCEENHANCING LIP (PEL)TECHNOLOGY W/BURR FREE CLOSEDHEM CONSTRUCTION

HOOD FRONTPANEL

INSULATION

HOOD TOP

TYPICALHANGER

BRACKET

THREADEDROD (1/2")

WASHER

HANGERBRACKET

1/2" NUT

2.125

HOODHEIGHT

0.750

HOOD LENGTH

4.54.5

5.0

3.3

3.0AIRSPACE

HOOD LENGTH

8.0 8.0

18.0

S2-1

L1

LT

LT

NLIGHT INPUT: 120VAC,15AMPS FROM BREAKER

1400W max.

BK WH

WT

RDRD

BK

TS1

T2-A T2-B

TS2

TERMINAL BLOCKS = 8 LB.IN

GROUNDING BLOCKS = 8 LB.IN

UNDER SUBJECT 891

Wiring Diagram #

FILE #E313951

USE MINIMUM

60° Copper Wire

TORQUE: FIELD WIRING:

UL LISTED

CONTROL INPUT: 120VAC,15AMPS FROM BREAKER

FIELD WIREFIRE SYSTEM

MICROSWITCH

CONTROL INPUT: 24/120 VAC,15AMPS FROM BREAKER

FIELD MOUNTED SWITCHFIELD WIRING TO SWITCH

REQUIRED

Switches - Ship Loose for Remote Mounting

110

X

X

X

20

TEMP INTERLOCK

CONTROL PANEL

Installation Location:

Ship Loose

STB

AF

D

ECPB

SV

ST

SLT

G

FS

EFSF

OLC

R

OR - orange

YW - yellowWH - white

RD - redPR - purple

FIELD WIRING

BK - blackBL - blue

UNLESS SPECIFIED

BR - brown

FACTORY WIRING

Shunt Trip Breaker

Air Flow Switch

Damper

Evap CoolerPushButton

Gas Solenoid

Starter

SwitchLight

Ground

Fire Switch

Exhaust FanSupply Fan

OverLoadContactor

Relay

TCTS

Temperature ControllerTemperature Sensor

LABEL DESCRIPTION

WIRE COLOR

ALL WIRING 90°C 14 GA.

This Control Panel only provides

control power to signal operation of

supply and exhaust starters.

Starters are Not provided by

manufacturer, to be provided by, wired

and mounted by others

TEMPERATURE INTERLOCK CALIBRATION

1. PRESS THE SET BUTTON TO SEE THE FIRST SET POINT.

(PRESS THE SET BUTTON TWICE, SLOWLY TO SEE THE SECOND

SET POINT)

2. PRESS THE UP/DOWN ARROW BUTTON TO CHANGE THE SET

POINT.

3. PRESS THE SET BUTTON TO VIEW THE CURRENT

TEMPERATURE.

4. CHECK SYSTEM OPERATION BEFORE MAKING ADDITIONAL

ADJUSTMENTS

T1-A T1-B

TC1

6 8 7

1 2

13 19 21 15

H1

L1

N1

N G

S1S1S1H

CP1

CP2

FS

NO NC

C

ST

TYP. EXHAUST

ST

TYP. EXHAUST

ST

TYP. SUPPLY

8.08.0

4.0

Volt

Gas Off w/Fans

Qty. Temp. Switches (0-1)

Remote Switches

Tempering SW

Audible AlarmGas ResetPower for Gas SolenoidPower for Shunt Trip

Heat SwitchCool SwitchAD Switch

One Switch for L & F

Qty. Light Switches (0-3)Qty. Fan Switches (0-3)

Hood Mark(s):

Fan MarkMotor HP

Panel Mark:

Off Delay RelaySF Failure Light

Aux. Supply ContactFan Failure Light (Appl.)

Tie in WWCP

Exhaust in Fire

Lights Out in Fire

DPDT Relay w/SFDPDT Relay w/EF

Fire Relay (#1)

Extra Fire Relay (#3)Extra Fire Relay (#2)

MUA Interface

WirePH FLA Breaker

Digitial Temperature InterlockMounted Sensors - FactoryMounted Sensors - Field

EF Failure Light

PROPRIETARY INFORMATION NOTICE

Electrical Prewire PackageTemperature Interlock

HILLS A.F.B.

T10-8-000 2-2.2

T10-8-000

EXHAUST COLLARCUT-OUT AREA

EXHAUST COLLAR NOTES: EXHAUST DUCT CONNECTION TO BE LOCATED WITHIN 48" FROM CENTER OF HOOD LENGTH TO CENTER OF DUCT CONNECTION.

UL LISTED HOOD ASSEMBLY TO BE USED ONLY WITH MANUFACTURER, LABELED SUB-ASSEMBLY, FOR EXHAUST HOOD WITHOUT EXHAUST DAMPER PART NO. DC.

EXHAUST DUCT CONNECTION IS TO BE A CONTINUOUS LIQUID TIGHT WELD TO HOOD.

REAR INTEGRAL AIR SPACE

EXHAUST ONLY DOUBLE SHELL

FRONT DETAIL

HOOD FRONT SECTION VIEW

AVAILABLE ON EXHAUST ONLY RECTANGULARHOOD MODELS ONLY

ON HOODS OVER 120"REFERENCE SCALED DRAWING FOR

ACTUAL LOCATIONS

HOOD HANGER BRACKET DETAIL

NOT TO SCALE

SHIPPED LOOSE DUCT COLLAR INST.DETAIL

TYPICAL HOOD HANGING METHOD

MARK: 56SECTION VIEW

MARK: 56 - SECTION 1ELEVATION VIEW

MARK: 56 - SECTION 1PLAN VIEW

59IN.OC

24"

L X

30"

WX

36"

H F

uel

Type: G

as

Range -

4 o

rm

ore

burn

ers

36"

L X

30"

WX

36"

H F

uel

Type: G

as

Griddle

36"

L X

30"

WX

36"

H F

uel

Type: G

as G

as

Char-

Bro

iler

24"

L X

30"

WX

36"

HS

pre

ader

16"

L X

30"

W X

36"

H F

uel T

ype: G

as

Fry

er

- F

ull

Vat

without D

ripboard

16"

L X

30"

W X

36"

H F

uel T

ype: G

as

Fry

er

- F

ull

Vat

without D

ripboard

OPTIONS AND ACCESSORIES

300 SERIES 18 GAUGE STAINLESS STEEL 100% CONSTRUCTION

UL 710 LISTED W/ OUT EXHAUST FIRE DAMPER - UL #R25625

BACK INTEGRAL AIR SPACE - 3 IN WIDE SHIPPED LOOSE EXHAUST

COLLAR(S) INCLUDES PERFORMANCE ENHANCING LIP (PEL) TECHNOLOGY STANDING SEAM CONSTRUCTION FOR SUPERIOR STRENGTH

STAINLESS STEEL FINISH FOR HIGH CORROSION RESISTANCE

13.5 1.1 13.5

39.4

11.3

99.6 99.6

199.1

3.4

60.8

4.5

90.0ABOVE

FINISHEDFLOOR

27.0

117.0

5.2

This document is and contains confidential trade secret information ofthe company and remains property of the company and is to be returnedupon request. Neither it nor information it contains may be reproducedor disclosed to persons not having a need-to-know consistent with thepurpose of the loan document without written permission.

ACCUREX MODELSTYLE / CONFIGURATION

GREASECUP ORDRAIN

HOODTEMP.

RATING

TOTALWEIGHT

SECTIONLOCATION

SECTIONLENGTH

WIDTH HEIGHT

HOOD DIMENSIONS

NO.HOOD

4;TYPE 1 KITCHEN HOOD MARK: 56

1177 IN.

54IN.

RIGHT600

DEG FSINGLE

649LBS.

24 IN.XXDW-177-S

DOUBLE WALL EXHAUSTONLY WALL CANOPY

EXHAUST PLENUM COLLARSHOOD SECTION #

COLLAR # WIDTH(IN.)

LENGTH(IN.)

DIAMETER(IN.)

VOLUME(CFM)

S.P.(IN. WC)

VELOCITY(FT/MIN)

DISTANCETO END (IN.)

88.5 10 35 NA 0.6091 / 1 3688 1517

TOTAL EXHAUST CFM - SECTION 1 3688 250 CFM / FT≈

ILLUMINATION DETAILS

QTY LENGTH

GREASE FILTRATION DETAILS

TYPE / MODELMATERIAL

HEIGHTFIXTURE TYPE

BULB / LAMP INFO

93.65 / 59IN. OC 4

16 IN.6

20 IN.

16 IN.X-TRACTORSTAINLESS STEEL

EQUIPMENT SCHEDULE

NO.HOOD

1LED TUBE 48 IN

LONG

3 X(2

LAMPS)

INTENSITYFT CANDLES QTY

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:5

4 P

M

3/8

" =

1'-0

"

HO

OD

DE

TA

ILS

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

04/0

2/12

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-602

Aut

hor

16 J

ULY

201

5

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 149 OF

CONSTRUCTION COMPLIES

WITH NFPA 96

RR

CHROME APPLIANCE DROPS

WIRING DIAGRAM(S)WIRING DIAGRAMSW/DPDT MICRO SWITCH ELECTRICAL SHUT OFF

AND CONNECTION TO COOKINGEQUIPMENT SHUT DOWN

SHUNT TRIPBREAKER

POWER TOCOOKING EQUIPMENT

ELECTRIC GAS VALVE - IF RESET RELAY ISUSED SEE OPTION A OR B AT RIGHT,MECHANICAL GAS SHUT OFF VALVE DOESNOT REQUIRE ELECTRICAL CONNECTION.

CONNECTION TO COOKING EQUIPMENT SHUT DOWN

}FANSTARTER

MANUALSWITCH

CONNECTION TO FAN SHUT DOWN

MANUAL RESET RELAY

ELECTRICAL RATING

(PART NO. 426151)

L1 HOT

110 VAC/60HZ

L2 NEUTRAL

* K1a AND K1b ARE N.O. WHEN K1 IS DE-ENERGIZED

}

POWER TO FAN(S)INPUT

120 VAC

N

~

NO

NC

DO NOT SHUT DOWN EXHAUST FANSWITH THIS METHOD OF WIRING, IFPROHIBITED BY LOCAL CODES.

1/3 HP, 10 AMP, 120 VAC1/2 HP, 10 AMP, 240 VAC13AMP, 28 VDC

GAS VALVESEE NOTE 3

693471

1

2

3

4

5SCREW

GND

POWER INDICATORRESET

BLACK

RED

BROWN

ANSUL SNAP-ACTION SWITCH (SWITCHCONTACTS SHOWN WITH ANSUL AUTOMANIN THE COCKED POSITION)

SNAP-ACTIONSWITCH PARTNO. 423877

BROWN

RED

BLACKL2

110V/60HZ

L1 MANUAL RESETRELAY PART NO. 14702

K1*

K1b N.O.

N.O. K1a

PUSHBUTTONSWITCH

GAS VALVESEE NOTE 3

}CONNECTION TO BUILDINGS ALARM

VOLTAGE FREECONTACTS FORBUILDING ALARM(S)

NC

INPUT

NONO

NC

INPUT120 VAC

N

NC

NO

1

2

3 4

5

6

INSULATED DOUBLESHELL FRONT

REMOVABLE GREASE CUP W/CONCEALED GREASE TROUGH

UL LISTED HIGH EFFICIENCY'GREASE-X-TRACTOR' FILTERS

INTEGRAL AIRSPACE

UL LISTED LIGHT FIXTURE

ANSUL R102 (WET CHEMICAL) FIRE PROTECTION SYSTEM - MODEL FSSC

4. GAS VALVES: "UL LISTED ELECTRICALLY-OPERATED SAFETYVALVE FOR NATURAL, OR LP GAS AS NEEDED OF APPROPRIATEPRESSURE AND TEMPERATURE RATING, 110V/60 HZ" OR ANSUL GASVALVES, PART NUMBERS 13707, 13708, 13709, 13710 AND 17643.

OPTION BRELAY PART #426151

RELAY COIL

A B

OPTION ARELAY PART #14702

TANK

RELEASEWITH TANK

ANSUL R102

2 FP2W

PIPE & CONDUITBY ANSUL DISTRIBUTOR

2 FP245

1 FP1N

1 FP1N

1 FP1N

3 FP3N

3 FP3N

1 FP1N

1 FP1N

REAR INTEGRAL AIR SPACE

1. STAINLESS STEEL ENCLOSURE2. AGENT STORAGE TANK3. EXPELLENT GAS CARTRIDGE4. ANSUL AUTOMAN RELEASE5. REGULATOR6. KNOCKOUT FOR WIRING MICROSWITCH

CONTROL PANEL

Wet chemical fire protection system to be Ansul R-102, designed in

compliance with UL 300 requirements.

-Verification of all cooking equipment make, model and location required for

all fire protection systems.

-All fire system piping is standardly to the right end of the hood unless a wall

is located on the right end.

-Ansul Automan Release to be located within 60" of hood.

The basic fire system will include the following:

-Gas shut-off valve, if required, to be supplied by Manufacturer (up to 2"

diameter as standard), and installed by a licensed plumber.

-Micro switch to be supplied by Manufacturer for connection to, but not limited

to, building alarm system(s), exhaust and supply fans and electrical power

shut down. Field wiring and connections to be performed by a licensed

electrician.

The basic fire system does NOT include the following:

-Full dump test other than wht is specified per the installation manual, or to

satisfy a state or local code. Permit and testing fees are not included unless

noted under the equipment schedule for the fire system.

-More then two trips to the jobsite or special transportation, or overnight

lodging requirements in remote areas. Normal travel distance is first 50 mi.

(80.5 km) from office.

- Special classes or additional labor for access to security sensitive areas.

-Installation of gas shut-off valve.

-Special drawings required to satisfy state or local code. Plan examination

fees, PE or FS Approval Stamp.

-Union labor, Government labor, or Prevailing wages required for final field

hook-up.

-Any and all electrical components/connections required to shut down fans,

shut off device for electric cooking equipment (shunt trip breaker), or activate

an alarm system, etc.

-Any dismantling or reassembly required to gain access to the fire

suppression piping located on the top of the hood.

-Rough-in hidden conduit for remote pull station or gas valve (flush mounted

pull station).

-Installation of more than (1) remote pull stations or distances greater than 20

ft (6.1M.)

-Parts or labor required to correct piping due to cooking equipment changes

or deviation from plans. OR Any charges for missing or additional parts other

then those indicated on the Fire Suppression Detail.

NOTES:

NOT TO SCALE

NOTES:1.2.3. DO NOT USE BLACK WIRE ON SNAP-ACTION SWITCH IN NORMALINSTALLATION. BLACK WIRE TO BE USED ONLY FOR EXTRANEOUSALARM, LIGHT CIRCUITS, ETC.

DPDT SWITCHES PROVIDED BY MANUFACTURER MAY BE WIREDPER TYPICAL EXAMPLES SHOWN. VERIFY WITH LOCAL CODESAND EQUIPMENT SUPPLIED AS THE CONNECTION NEEDED FOR

YOUR INSTALLATION.

DENOTES FIELD INSTALLATION.DENOTES FACTORY INSTALLATION.

VERIFICATION OF HOOD HANGING HEIGHTABOVE FINISHED FLOOR (A.F.F.) IS REQUIREDFOR CORRECT PLACEMENT OF FIRE SYSTEM

NOZZLES.

HOOD HANGING HEIGHT FORFIRE SYSTEMS

RECOMMENDED HANGING HEIGHT = 80" FROMFINISHED FLOOR TO LOWER FRONT EDGE OF

HOOD.

OTHER HANGING HEIGHT = __________" FROMFINISHED FLOOR TO LOWER EDGE OF HOOD.

MARK: 56SECTION VIEW

MARK: 56 - SECTION 1ELEVATION VIEW

MARK: 56 - SECTION 1PLAN VIEW

59IN.OC

24"

L X

30"

WX

36"

H F

uel

Type: G

as

Range -

4 o

rm

ore

burn

ers

36"

L X

30"

WX

36"

H F

uel

Type: G

as

Griddle

36"

L X

30"

WX

36"

H F

uel

Type: G

as G

as

Char-

Bro

iler

24"

L X

30"

WX

36"

HS

pre

ader

16"

L X

30"

W X

36"

H F

uel T

ype: G

as

Fry

er

- F

ull

Vat

without D

ripboard

16"

L X

30"

W X

36"

H F

uel T

ype: G

as

Fry

er

- F

ull

Vat

without D

ripboard

FIRE SYSTEM MARK: 24

SUPPLYFAN QTY

4;ELECTRICAL CONTROL BOX

DESCRIPTION / ACCUREX MODELMOUNTING LOCATION (CONTROL PANEL / SWITCHES)

EXHAUSTFAN QTY

POWERFREQUENCY

4;MARK: TEMP INTERLOCK

TEMPERATURE INTERLOCK / TEMPERATURE INTERLOCKN/ASHIP LOOSE / (SHIP LOOSE FOR REMOTE MOUNTING) N/A 60 CYCLE

CONTROL PANEL ENCLOSURE - GRAY ENCLOSURE (NEMA-3R) - DIMENSIONS 8 X 8 X 4

2 POSITION FAN SWITCH - QTY 1

INTEGRATED EXHAUST TEMPERATURE INTERLOCK SYSTEM

-FACTORY MOUNTED EXHAUST TEMPERATURE SENSORS - QTY 2

-COMPLIES WITH INTERNATIONAL MECHANICAL CODE 2006 SECTION 507.2.1.1

2 POSITION LIGHT SWITCH - QTY 1

FIRE SYSTEM PROTECTED HOOD(S) (UL-300) (MARK NAME / SECTION#)

56 SECTION 1 - (LENGTH 177.0 IN.)

SUPPLY LINEMOUNTING

FIRE SUPPRESSION SYSTEM

MANUFACTURER / MODELSUPPRESSANT TYPE

DETECTIONFLOW

POINTS

MARK: 24

ANSUL R-102FUSIBLE LINKWET CHEMICAL

LEFT END REMOTEMOUNTED (TANK &

BRACKET)

CONTINUOUS15 UTILIZED16 AVAILABLE

FULL INSTALLATION (INCLUDES PRE-PIPED HOOD(S) WITH DETECTION AND FACTORYCOORDINATED INSTALL)

CHROME SLEEVES FOR FACTORY PROVIDED APPLIANCES DROPS - INCLUDED

METAL BLOW-OFF CAPS - INCLUDED

MISC ADDITIONAL FEES (VERIFY ADDITIONAL FEES THAT ARE COVERED)

GAS VALVE - INCLUDED - ELECTRICAL SHUTOFF VALVE WITH RESET RELAY, 2", 110V, 60HZ -PART# 13710

SUPPRESSION AGENT - INCLUDED - 4.5 GAL. - [(1) 1.5, (1) 3.0 TANK(S)]

REMOTE PULL STATION - STANDARD - INSTALLATION AT SINGLE POINT OF EGRESS

TANK ENCLOSURES (STAINLESS STEEL) FOR REMOTE MOUNTING - INCLUDED

23.5

16.57.5

13.5 1.1 13.5

39.4

11.3

99.6 99.6

199.1

3.4

60.8

4.5

90.0ABOVE

FINISHEDFLOOR

27.0

117.0

5.2

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:5

4 P

M

3/8

" =

1'-0

"

HO

OD

DE

TA

ILS

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

06/2

4/15

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-603

Aut

hor

16 J

ULY

201

5

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 150 OF

64

67

69

2'-10"

4"

71

SERVICE COUNTER

25'-7"

1

QF-802

2

QF-8023

QF-802

71

67

65

67

70

70

2'-10"

4"

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

ACCESS PANEL

SERVICE COUNTER

25'-7"

1

QF-802

2

QF-8023

QF-802

44

45

46 47 52 53 46

54

61

62 7263

51

56

EXHAUST HOOD

WALL SHELF

11'-3"

3'-0"

6"

WORK COUNTER

11'-3"

4

QF-8025

QF-802

3'-0"

6"

2'-0"

WALL SHELF

6'-0"

UNDER-SHELF

UNDER-SHELF

24

27

52

26

UNDER-SHELF

34

3333

32

30

7"

3'-1"

31

LEVERWASTE

LEVERWASTE

5

6

QF-8027

QF-8028

QF-802

9

QF-802

10

QF-802

UNDER-SHELF

LEVERWASTE

13

14

12

7

5

6

6"

3'-0"

PREP TABLE

6'-3"

9

QF-802

10

QF-802

6

3'-0"

6"

PREP TABLE

20'-8"

UNDER-SHELF

UNDER-SHELF

UNDER-SHELF

UNDER-SHELF

UNDER-SHELF

11

QF-802

1111

UNDERSHELFUNDERSHELF

OPEN

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:5

7 P

M

1/2

" =

1'-0

"

EQ

UIP

ME

NT

ELE

VA

TIO

NS

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

04/0

2/12

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-701

Aut

hor

16 J

ULY

201

5

1/2" = 1'-0"1

SERVICE COUNTER

1/2" = 1'-0"2

SERVICE COUNTER

1/2" = 1'-0"3

COOKLINE

1/2" = 1'-0"4

WORK TABLE & WAREWASH

1/2" = 1'-0"5

PREP TABLE

1/2" = 1'-0"6

PREP TABLE

1/2" = 1'-0"7

MOBILE WORK TABLES

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 151 OF

6

5UNDERSHELF UNDERSHELF

3'-0"

6"

PREP TABLE

10'-11"

10

QF-80211

QF-802

OPEN

11 11

UNDERSHELF UNDERSHELF

3'-0"

MOBILE TABLE

4'-0"

MOBILE TABLE

4'-0"

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:5

8 P

M

1/2

" =

1'-0

"

EQ

UIP

ME

NT

ELE

VA

TIO

NS

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

06/0

1/15

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-702

Aut

hor

16 J

ULY

201

5

1/2" = 1'-0"1

WORK TABLE

1/2" = 1'-0"2

MOBILE WORK TABLES

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 152 OF

DEPTH PER QUARRYTHICKNESS. HEIGHTTO BE 6" COVINGRADIUS SHALL BE3/8" MINIMUM

2"

GROUT BY GENERALCONTRACTOR

VISQUEEN OR HYDORLENE VAPORBARRIER AT BOTTOM AND SIDE OFDEPRESSION, JOINTS LAPPED 6" MIN.(BY WALK-IN MANUF.)

(2) 2" URETHANE INSULATION,STAGGERED JOINTS

(BY WALK-IN MANUF.)

15 LB. FELT SHEETSOVER INSULATION,

FLASHED UP HEIGHTOF DEPRESSION,

JOINTS LAPPED 6"MIN.

(BY WALK-IN MANUF.)

QUARRY TILE

CONC. SLAB(BY GENERAL

CONTRACTOR)

WALL PANELS, SET ONCONTINUOUS GALV.

STL. TRACK, ANCHOREDTO FLOOR WITH DRIVE

PINS AT 24" O.C.

INT. & EXPOSED EXT. COVEBASE (TO MATCH WALL)

(COOLER)(FREEZER)

SEE NOTE "A"

GRATE IS TO BE SUPPORTED ATALL CONTACT POINTS ON 4 SIDES

9" SQ. (230SQ.) HOLETHRU SLAB "

A"

SE

E N

OT

E

OUTLINE OFSEEPAGE FLANGE

VARIES. SEE BUILDING WORKS PLAN

SEE NOTE "A" 2 1/4" 2 1/4"

MIN

.4"

1 1

/2"

1"1"

6"

# 14 GA. ST/STL SEEPAGEFLANGE TACK WELD TO PANAND SEAL WATER TIGHT

PLAN

1/2

"

WATERPROOF MEMBRANEBY GEN. CONTR.

TAIL PIECE BY K.E.C., NON-HUBCOUPLER & PLUMBING PIPE BY G.C.

SILICONE SEALANTAROUND PERIMETER

BY G.C.

FINISHED FLOOR BY G.C.

NOTES:A. GRATING SIZE TO BE 6 3/4" (170) LESS

THAN THE WIDTH AND LENGTH OF SLABDEPRESSION

B. STAINLESS STEEL SUBWAY GRATE TOMEET ADA REQUIREMENTS

C. IF GRATING IS NOT FACTORY CUT,FINISH CUT EDGES AS PERMANUFACTURER'S RECOMMENDATION

1

LONGITUDINALSECTION

1

GRATING TO BE FLUSHW/ TOP OF TROUGH

ANTI-SPLASH

ST. STL., WOOD,OR GALVANIZED

BASE

4" CLEARANCEAROUND

FINISHED FACEOF FLOOR SINK

FLOOR SINK

HUGEDGE

7'-0"

2" 2"

16 GA. ST. STL.CONSTRUCTION

SILICONE ATGAPS

4" X 4" OCTAGONBOX BY

ELECTRICALCONTRACTOR,

FLUSH MOUNTEDIN WALL

1/2" DIA. EMPTYCONDUIT IN WALLEXTENDED UPABOVE CEILING BYELECTRICALCONTRACTOR

REMOTE FIRE PULLSTATION BY F.S.E.C.

12"

FINISHEDCEILING LINE

FLO

OR

48"

TO

FIN

ISH

ED

1/2

NOTES:4/0 BOX WITH 1/2 KO'S POSITIONED AS SHOWN WITH TABS INUPPER RIGHT AND LOWER LEFT OF BOX. TO BE 48" ABOVEFINISHED FLOOR. 1/2" E.M.T. TO BE 12" ABOVE FINISHED DROPCEILING LINE WITHOUT BENDS OR OFFSETS. ONE 4/0 BOX TOBE PROVIDED FOR EACH REMOTE PULL STATION. WHEN TWOREMOTE BOXES ARE MOUNTED SIDE BY SIDE, THE DISTANCEBETWEEN CENTERS SHALL NOT BE LESS THAN 7".

REMOTE PULL STATION DETAIL

4'-0"

3" MINIMUM AIR SPACEBETWEEN TOP OF EXHAUSTHOOD AND COMBUSTIBLEMATERIAL

CLOSURE PANEL TOFINISH CEILING

EXHAUST HOOD

VA

RIE

S2'-0"

7'-0"

A.F

.F.

WALLBACKING

14 GA. ST/STLBUMPER RAIL, SEE

FLOOR PLAN FORLOCATIONS

#14 PANHEADPHILLIPS SCREW

AT 32" O.C.

1/2

" 1/2

" 2"

1/2

" 1/2

"

1" 55º

CLOSED END CAPS- WELD, GRIND AND

POLISH

WALL

SILICONE @ GAP

Z CLIP

ST. STL.BACKSPLASH

1"

6 -

8"

ST. STL. DOOR

1/4" ST. STL.FLATBAR

ST. STL. DOOR

1/4" ST. STL.FLATBAR2 1/2"

1/2" 1/2"

5/8

"

1/2

"

2"

1/2

" 3/8

"

5/8"

3/8" 1/4" R.

STAINLESS STEELINTEGRAL PULL

1"

1"

1/16" 1/16"

STAINLESS STEEL ORMILLWORK DOOR, SEE

ELEVATIONS &DETAILS

27"

MIN

.

29"

MIN

.

34"

MA

X.

17" MIN.CLEARANCE8" MIN. KNEE

CLEARANCE6" MAX. TOE

ADA FAUCET& CONTROLS

INSULATEDPIPING (TYP.)

2'-10" 48"

MA

X

30" MAX 24" MAX.

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:5

8 P

M

1"

= 1'

-0"

CO

NS

TR

UC

TIO

N D

ET

AIL

S

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

04/0

2/12

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-801

Aut

hor

16 J

ULY

201

5

1" = 1'-0"1

FREEZER DEPRESSION DETAIL

1" = 1'-0"2

FLOOR TROUGH DETAIL

1" = 1'-0"3

FLOOR SINK DETAIL

1" = 1'-0"4

CORNER GUARD DETAIL

1" = 1'-0"5

FIRE PULL BOX DETAIL

1" = 1'-0"6

HOOD ENCLOSURE PANEL

1" = 1'-0"7

BUMPER GUARD DETAIL

1" = 1'-0"8

BACKSPLASH DETAIL

1" = 1'-0"9

PIVOT HINGE DETAIL

1" = 1'-0"10

INTEGRAL DOOR PULL DETAIL

1" = 1'-0"11

ACCESSIBLE HAND SINK DETAIL 1" = 1'-0"

12ACCESSIBLE SIDE REACH DETAIL

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 153 OF

COVEDBASE BYG.C. (TYP.)

ACCESS PANEL &REMOVABLESHELF

GALV. CURBBY ST/STL.

FABRICATOR

BUILDING WALL- SEE ARCH.

DRAWINGS FORDETAILS

4"

2"

11"

2"

11"

2"2

"

2'-10"

3'-11"

4"6"

UTILITYCHASE

4"

QUARTZ TOP- REFER TOARCH.DRAWINGS

GALV. CURBBY ST/STL.

FABRICATOR

BUILDING WALL- SEE ARCH.

DRAWINGS FORDETAILS

2'-10"

3'-11"

4"6"

UTILITYCHASE

4"

QUARTZ TOP- REFER TOARCH.DRAWINGS

UNDER-COUNTERREFRIG.

2"

COVEDBASE BYG.C. (TYP.)

GALV. CURBBY ST/STL.

FABRICATOR

BUILDING WALL- SEE ARCH.DRAWINGS

FOR DETAILS

2'-10"

3'-11"

4"

UTILITYCHASE

4"

QUARTZ TOP- REFER TOARCH.DRAWINGS.

4"

2'-4"

2"

ACCESSPANEL

3"

COVEDBASE BYG.C. (TYP.)

REMOVABLESHELF

GALV. CURB BYST/STL.

FABRICATOR 4"

2' -

6"

2"

3' -

0"

6"

2' - 6"

2' -

0"

WALL SHELF,WITH #14 GA.

ST/STL SHELFBRACKET

1'-0"

2"

4"

1"

COVEDBASE BYG.C. (TYP.)

GALV. CURB BYST/STL. FABRICATOR 4

"2'-6"

2"

3'-0"

6"

2'-6"

7"

1'-2" 6"

SOAP &TOWELDISPENSERS

WALL SHELFWITH

CONCEALEDBRACKET

1'-0"

1"

4"

2"

FAUCET

2'-0"

10"

3'-1"

3"

2"

2'-6"

1"

6"

2"1/4" THICK X 2"

ST/STL. FLATBARUTENSIL RACK

W/ ST/STL.SLIDING HOOKS

8" O.C.

FAUCET

1 5/8" DIA.ST/STL. LEGS

& GUSSETS W/ADJ. BULLET

FEET

LEVERWASTE

1'-2"

10"

2"

6'-6"

10"

1 5/8" DIA.ST/STL LEGS &

GUSSETS W/ADJ. BULLET

FEET

ST/STL LOWSHELF W/ GALV.

STL. HATSECTION

2"

ROLLEDEDGE

3'-1"

3"

2'-6"

7"

2'-6"

10"

3'-0"2

'-0"

2"

6"

1 5/8" DIA.ST/STL LEGS &

GUSSETS W/ADJ. BULLET

FEET

ST/STL LOWSHELF W/

GALV. STL. HATSECTION

2" 2'-0"

2"2

"

WALL SHELFWITH #14 GA.

ST/STL SHELFBRACKET

HUG EDGE(TYPICAL)

1'-0"

1"

2'-6"

3'-0"

2"

6"

1 5/8" DIA.ST/STL LEGS

& GUSSETSW/ ADJ.

BULLET FEET

2"

FAUCET

1'-0"

LEVERWASTE

2'-0" 3"

10"

2'-6"

3'-0"

2"

6"

1 5/8" DIA.ST/STL LEGS

& GUSSETSW/ ADJ.

BULLET FEET

2"

2'-6"

10"

3'-0"2

'-0"

2"

6"

1 5/8" DIA.ST/STL LEGS &

GUSSETS W/ADJ. BULLET

FEET

ST/STL LOWSHELF W/

GALV. STL. HATSECTION

2"

RTA DESIGN SUBMITTAL - FOR CONSTRUCTION

CK

D B

Y:

SO

LIC

ITA

TIO

N N

O.:

DA

TE:

DR

WN

BY

:

LE

E &

SA

KA

HA

RA

AR

CH

I TE

CT

UR

E P

LA

NN

ING

IN

TE

RIO

RS

AR

CH

ITE

CT

S A

IA16

842

Von

Kar

man

Ave

., S

uite

125

, Irv

ine,

CA

926

06-4

934

Tel.

(94

9) 2

61-1

100

Fax

. (94

9) 2

61-1

144

ww

w.le

esak

.com

DE

SIG

NE

D B

Y:

DO

UG

LE

E

SHEETIDENTIFICATION

154

CO

NTR

AC

T N

O.:

FIL

E N

UM

BE

R:

PLO

T D

AT

E:

PLO

T S

CA

LE:

SU

BM

ITT

ED

BY

:

SIZ

E:

FIL

E N

AM

E:

AN

SI D

1

A

SEAL

HQ

AIR

FO

RC

E P

ER

SO

NN

EL

CE

NT

ER

, SE

RV

ICE

S D

IRE

CT

OR

AT

ELA

CK

LAN

D A

IR F

OR

CE

BA

SE

SA

N A

NT

ON

IO, T

EX

AS

F41

999-

14-F

-142

2

1450

8

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

7/1

4/2

015 3

:23:5

9 P

M

1"

= 1'

-0"

EQ

UIP

ME

NT

SE

CT

ION

S

GO

LF C

LUB

HO

US

EK

RS

M09

5002

WO

RK

OR

DE

R #

5412

7H

ILL

AIR

FO

RC

E B

AS

E, U

TA

HC

heck

er

Aut

hor

06/0

1/15

HIL

L A

IRF

OR

CE

BA

SE

, UT

AH

QF-802

Aut

hor

16 J

ULY

201

5

1" = 1'-0"1

SERVICE COUNTER

1" = 1'-0"2

SERVICE COUNTER

1" = 1'-0"3

SERVICE COUNTER W/ ACCESS PANEL

1" = 1'-0"4

WORK COUNTER

1" = 1'-0"5

WORK COUNTER W/ HAND SINK

1" = 1'-0"6

3 COMPARTMENT SINK

1" = 1'-0"7

DISH TABLE

1" = 1'-0"8

WORK TABLE W/ WALL SHELF

1" = 1'-0"9

WORK TABLE W/ PREP SINK

1" = 1'-0"10

WORK TABLE

1" = 1'-0"11

WORK TABLE

MA

RK

DE

SC

RIP

TIO

ND

AT

EA

PP

R.

SHEET 154 OF