helios wiser diode dental laser
DESCRIPTION
Introducing the Helios Wiser 980nm diode dental laser with Tissue Optimized Pulsing® (7 and 14 Watt models). The 980nm wavelength lies at a peak in the light-water absorption curve. 980nm has the ability to work fast yet keep thermal damage low. With Tissue Optimized Pulsing®, Wiser soft tissue treatments come yet closer to being bloodless, painless, and quicker healing. Contact Helios Laser: www.helioslaser.com 216-220-0492 [email protected]TRANSCRIPT
Diode soft tissue laser
7 or 14 W power
Tissue Optimized Pulsing®Wavelength
Comfort
Tissue Optimized Pulsing®with980 nm diode laser
7 and 14 Watt models
980 nm The most efficient wavelength for cutting and coagulation
The Helios WiserSensaTouch handpiece
Autoclavable tips
Quick-charging capacitor power
216-220-0492 [email protected] 160 E. 238th St. Cleveland, OH 44123www.helioslaser.com
Call on Helios Laser
Less PainLess BloodFaster Healing
Save TimeImprove outcomesOffer more procedures
PowerAvailable at 7 or 14 WattsCuts quickly and cleanly at all pulsed settings
PulsingTissue Optimized Pulsing®The Wiser pulsing regime is adapted to vascular biotype
980 nm wavelength
Clinical
Work in-Contact and non-Contact
Balance cutting and coagulation Versatile!
Bactericidal and analgesic effects
Machine
Near-Infrared wavelength soft tissue
Fiber-delivered beam simple
Low power low cost
Small and lightweight portable
Diode dental laser characteristics
Soft Tissue Surgery
Diode Use
Pulpotomy: adjunct to root canal treatment
Aphthous ulcer
Cementum mediated periodontal ligament new attachment (LANAP)
Coagulation of surgical and extraction sites
Coronal pulp removal: adjunct to root canal
Sulcular debridement
Herpetic and Vasuclar Lesions
Whitening
Periodontics
Excision and incision, implant recovery
Laser Assisted Periodontal Therapy
Endodontics
Photo-therapy
Photo-biomodulation
In-Contact
Non-Contact
Common soft tissue surgical procedures
Cosmetic crown lengthening
Uncovering teeth for orthodontics & implants
Soft tissue ridge modification
Operculectomy
Frenectomy
Tongue tie
Fibroma removal
Ovate pontic site preparation
4. 3 weeks post-op3. Immediately post-op
2. In course1. Initial condition
Gingival Contouring& Tissue Retraction
(for porcelain veneers)
Advantages of Laser Dentistry
Reduction of bacteria at surgical site
Minimal damage to surrounding tissues
Improved patient comfort
More precise, conservative dentistry
Treat multiple quadrants: perform multiple procedures
New patient referrals
Dollars and Sense
Save 15 minutes per day on crown troughing
Single tooth gingivectomy……...$135Frenectomy………………………$2651 hr scaling & LAPD …………... $245Aphthous ulcer treatment………$ 95
@ 1 per month
$740 x 10 mo = $7400 income
Hourly production of $500 $125 daily savings
180 days of practice per year $22,500 annual savings
Fingertip Operation No footswitch/cable Armored delivery cable
Capacitor-driven lasing 90 s charge gives 1 hr lasing
Battery-driven controls 3 hr charge gives 20 hr system use
Comfort = Portability
Bianco whitening lens options
Comfort = SensaTouch handpiece
Multi-tooth
Single-tooth
Surgery
Threaded tip mount
SensaTouch
3 touch sensitivity
settings
With threaded tip retaining rings and mount, tips attach securely to the handpiece.
Threaded retaining
rings
Soft Tissue Surgery
Whitening
Periodontics
Endodontics
Photo-therapy
Multi-tooth
200µm
400µm
300µm
300µm
Single-tooth
Comfort = Treatment-Specific Tips
Autoclavable multiple times
tip
Wiser MSRP tip pricing & use costs
Base Kit 4 Tip Packs (4 tips each):
2-year Swap Warranty Overnight shipping Extendable to 5 years
3 Laser Safety Glasses
User, Training & Applications ManualsCD & USB
Tip Bender
Charger
Laser unit
Quick-Startguide
Laser Safety Labels
Surgery Endo Perio Implant
Comfort = Complete Package
Year 3 $ 990
Year 4 $ 1,089
Year 5 $ 1,197
Years 3 & 4 $ 1,512
Years 3-5 $ 2,924
Swap Warranty MSRP extensions(single swap)
Michael D. Swick, DMD Diplomate, American Board of Laser SurgeryEducator, Laser Education International
Voyager Laser Training™ (2CEU)Dr. Swick hosts a one-on-one, hands-on clinical procedure training. The practitioner determines the session sequence in advance. Helios supplies a portable digital video studio & biological materials.
Wiser Online Quick Start Go-to-Meeting with Helios personnel Start lasing immediately Free with Wiser purchase
Comfort = Online Training
Tissue Optimized Pulsing®
Why Wiser?
Comfort
SensaTouch handpiece
Capacitor driven laser
Autoclavable tips Reusable up to 4 times
Two-minute charging
Eliminates another footswitch
Surgery, Bleaching & BiostimBianco whitening kits
‘Thermal Transfer’Convert laser light to useful tissue heat
Wavelength Pulsing
Why Wiser?
Laser-Tissue interaction
Clinical Performance
Wavelength and WaterFundamental couple in soft tissue laser surgery
Er:YAG (2,940nm)
Red diode (500nm)
Near Infrared diode(810, 940, 980, 1064nm)
Wiser 980nm
100 1,000 10,000 100,000
Y-
Light penetration depthcoagulation
Wavelength
X =
+
+
0
Light absorption ratecutting
Y+
Water = soft tissue chromophore
soft tissue = 60-80% intercellular H20
2-7% HB/HBO2
~ % melanin
0
750 800 850 900 950 1000 1050 1100 1150
0.9 ----
0.6 –--
0.3 ----
0.0
H2O 70%
HB/HBO2 7%
HB/HBO2 extrapolated
Summed data
810nm
Wavelength (nm)
Ab
sorp
tio
n (
cm-1)
NIR water absorption curves for H2O and HB/HBO2
1064nm
980nm
Wavelength
Michael D. Swick, DMD Diplomate, American Board of Laser SurgeryEducator, Laser Education International
Tissue Optimized Pulsing®
Pulsing
Three intraoral vascular biotypes
Wiser advantage: Pulsing is adapted to vascular biotype
Tissue Optimized Pulsing®
Granulation Tissue
easier to cut & damagehighly charged with chromophores
Normal Tissue
requires “average” power to cut“average” water, Hbbo & melanin
Fibrous tissue
requires more power to cutfewer chromophores
Rule: As vascularity decreases, Average Power requirements increase
Pulsing
More power Less restQuicker attack
Less powerMore restSlower attack
Quicker cutting / Less coagulation Slower cutting / More coagulation
Granulation tissue, Medium PulsingFibrous tissue, Super Pulsing
Pulse cycle 1 2
Power phase (%) 50 50
T-On / T-Off (µs) 20 / 20 20 / 20
Rest phase (%) 50 50
Super Pulsing (SP): 50% Emission Cycle @ 7W power / 25kHz pulse freq
Frequency 25kHz 25kHz
T-On T-Off Power (W)
7.0 Delivered
3.5 Average
0.0
Tissue Optimized Pulsing®
Medium Pulsing (MP): 14% Emission Cycle @ 7W power / 285Hz pulse freq
Pulse cycle 1 2
Power phase (%) 14 14
T-On / T-Off (µs) 500 / 3000 500 / 3000
Rest phase (%) 86 86
Frequency (Hz) 285 285
T-On T-Off7.0 Delivered
0.01.0 Average
Power (W)
Sulcular Decontamination
Fibrous tissue Incision/Excision
Pulsing
UpCircle
Enter
Wiser Navigation
Menu
LeftRight Down
Preset Treatment List
*APW = Average Power (Watts)
Treatment Procedure Mode APW* Sec Tip
1 Sulcus Preparation 1.1 Posterior/healthy SP 2.5 4001.2 Posterior/hyperemic MP 2.5 4001.3 Anterior/healthy SP 2.5 4001.4 Anterior/hyperemic MP 1.5 400
2 Periodontics 2.1 Sulcular Decon DDS MP 1.5 30 4002.2 Sulcular Decon RDH MP 0.8 30 4002.3 Deepithel-Curet DDS SP 2.3 30 4002.4 Deepithel-Curet RDH SP 1.4 30 400
3 Surgery 3.1 Biotype=fibrous SP 3.5 300
3.2 50% T-on FP 3.5 300
3.3 MP 3.5 3003.4 Biotype=normal SP 2.5 300
3.5 35% T-on FP 2.5 300
3.6 MP 2.5 3003.7 Biotype=granulation SP 1.5 300
3.8 20% T-on FP 1.5 300
3.9 MP 1.5 300
4 Coagulation 4.1 moderate hemostasis CW 1.0 3004.2 severe hemostasis CW 2.0 300
5 Endodontics 5.1 Pulpotomy SP SP 3.5 2005.2 Pulp Cap MP 1.0 10 2005.3 Rt Canal Decon SP SP 1.0 10 2005.4 Rt Canal Decon MP MP 1.0 10 200
6 Implant Recovery 6.1 Biotype=fibrous SP 2.5 3006.2 Biotype=granulation MP 2.5 3006.3 Implant Decon MP 1.5 20 300
7 PTH 7.1 Apthous-Herpes SP SP 2.0 120 3007.2 Vascular Lesions MP 3.5 3007.3 Vascular Lip MP 2.0 300
8 PBM 8.1 Analgesia CW 0.7 60 3008.2 Biostimulation CW 0.1 60 3008.3 Hypersensitivity CW 0.2 20 300
9 Whitening 9.1 Small Lens activation CW 2.0 15 SL9.2 Large Lens activation CW 5.0 30 LL
SP = Super PulsingFibrous Biotypes fibroma removal frenectomy operculectomy
FP = Fast PulsingNormal Biotypes gingival incision posterior sulcus prep sulcus debridement (DDS)
MP = Medium Pulsing Granulation Biotypes abscess treatment anterior sulcus prep sulcus debridement (RDH)
Tissue Optimized Pulsing®
Quick-Start
In-Contact
Non-Contact
Why Wiser?
Clinical Performance
980 nm wavelength Tissue Optimized Pulsing®
Diode soft tissue laser
7 or 14 W power
Tissue Optimized Pulsing®Wavelength
Comfort
Tissue Optimized Pulsing®with980 nm diode laser
7 and 14 Watt models
980 nm The most efficient wavelength for cutting and coagulation
The Helios WiserSensaTouch handpiece
Autoclavable tips
Quick-charging capacitor power
216-220-0492 [email protected] 160 E. 238th St. Cleveland, OH 44123www.helioslaser.com
Call on Helios Laser
Less PainLess BloodFaster Healing
Save TimeImprove outcomesOffer more procedures
PowerAvailable at 7 or 14 WattsCuts quickly and cleanly at all pulsed settings
PulsingTissue Optimized Pulsing®The Wiser pulsing regime is adapted to vascular biotype
980 nm wavelength