Heating equipment7
Heating equipment
Hea
ters
GTG-SHKAF (KSH/TERMO-BOX)
thermo cabinet
p. 304
Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-
480W-T190)
p. 307
Heating plate GTG-PLASTINA2 (RETO-PLATE-
CAVO-150W and RETO-PLATE-CAVO-300W)
p. 309
Heating plate GTG-PLASTINA1
(RETO-PLATE-T190)
p. 311
Heating cable GTG-CABLE1 (RETO-
CORD/S)
p. 313
Plug for heating cable GTG-ZGK (MC-CORD)
p. 316
Plate heater GTG-RADIATOR
(RETO-PLATE-RADIATOR/M)
p. 318
Programmable thermostat GTG-PT (SA-TERMOSTAT-D)
p. 320
Box for heating cable connection GTG-VK2
(SA-A2CORD)
p. 323
Datasheet
ОПРОСНЫЙ ЛИСТ НА ВЗРЫВОБЕЗОПАСНЫЕ И ПОЖАРОБЕЗОПАСНЫЕ ТЕРМОШКАФЫ (КОЖУХИ) ГТГ, УВГ (КШ)Максимально допустимые внешние габариты шкафа
В = _______мм Ш = _______ммГ = _______мм
Максимально допустимый вес шкафа (кожуха) _______ кг
Материал изготовления корпуса Материал изготовления утеплителя
Малоуглеродистая сталь с лакокрасочным покрытием (коэф. теплопередачи 5,5 Вт/м2 К) Нержавеющая сталь 03Х18Н10 (AISI304) (коэф. теплопередачи 4,5 Вт/м2 К) Ударопрочный бесшовной химически инертный полимер (коэф. теплопередачи
3,5 Вт/м2 К) Коррозионностойкий модифицированный алюминиево-кремниевый сплав (коэф.
теплопередачи 12 Вт/м2 К)
Без утеплителя Металлизированный армированный утеплитель Негорючий экструзионный вспененный полимер
Способ крепления
Крепление к стене/раме Крепление к бетонному
основанию Напольная установка.
Высота подставки ______ мм
Крепление к морской палубе Разъемная установка на трубу
(горизонтальная или вертикальная) Крепление к опоре
Установка в зону
Группа смеси: IIА IIВ IIС IIICТемпературный класс: Т1 Т2 Т3 Т4 Т5 Т6Зона установки: Зона 0 Зона 1 Зона 2
Невзрывоопасная пожароопасная зона РН
Применение Установка на открытом воздухе УХЛ1 Установка на морской платформе или судне ОМ1 Установка в неотапливаемом помещении Установка под землей Установка в отапливаемом помещении
Географическая точка установки шкафов (регион, ближайший населенный пункт) или температура окружающей среды
от –____ °С до +____ °С
Перепады температурыМощность потерь оборудования/
носителя (самонагревания) внутри шкафа (кожуха)
Место для рисунка заказчика с примерным расположением узлов и местами их крепления
Низшая t окружающей среды в месте установки ____°СМакс. t окружающей среды в месте установки ____°СЖелаемая внутренняя t ____°С или поддерживаемая t внутри шкафа: от ____°С до ____°С
Минимальная _____Вт Максимальная _____ВтПостоянная _____ВтСредняя _____Вт
Коэффициент заполнения шкафа (кожуха) Необходимое внутреннее пространство____ (0 – пустой шкаф, 10 – весь объем шкафа занят оборудованием) В = ___ мм Ш = ___ мм Г = ___ мм
Тип климатического устройства шкафа (кожуха) Требуемый способ защиты оборудования заказчика от действия агрессивных сред
Пассивная С электрообогревом с теплоотводом — полупроводниковый охладитель IP66/68 с теплоотводом — наружный обдув вентилятором IP55 с теплоотводом — вентилятор для проветривания и охлаждения IP05
Напряжение электропитания климатического устройства ______В АС DC
Герметичный корпус, IP66 Поддержание избыточного давления (малый расход сухого
воздуха) IP67 Герметичный корпус, стойкий к затоплению IP68 Продув сухим воздухом (большой расход сухого воздуха) IP66
Антивандальная защита Освещение
Корпус из стали 4мм Замок в двери Звуковая сигнализация Удаленное видеонаблюдение Герконовый дверной охранный извещатель Возможность установки навесного замка Противосъемное крепление (разной конструкции в зависимости от способа установки)
Светильник для освещения внутри Концевой выключатель двери Маскировочный светильник для осещения внутри Выключатель
Звукоизоляция Устройства для монтажа оборудования заказчика
Облицовка шумозащитным материалом Внутренние обшивка-панели с перфорацией круглыми отверсти-ями на боковых стенках под саморез для последующего крепления монтажных элементов
Угол открывания дверей не менее 105° Крепление для размещения блков в 19” стандарте
Ввод кабелей и трубКабельные вводы для кабелей
Неброни-рованных
Бронированных / с оплеткой
Гибкого металлору-
кава
Полимерной гофры
Трубной электропро-
водкиd шт.
123
Кабельные вводы для кабелей
Стальная труба
Стальная труба в теплоизо-
ляции
Пластико-вая труба
Медная труба
Резиновый шланг
Металличе-ский гибкий
шлангd шт.
123
Проходки для кабелей/труб В = ___ мм Ш = ___ мм В = ___ мм Ш = ___ мм
Защита оборудования заказчика от пожара
Пожарный тепловой извещатель Пожарный извещатель пламени Автономная система газового пожаротушения Дверные уплотнители – СТОП ОГОНЬ
Устройства для доставки и установки
Транспортные рым-болты для установки краном Установка на поддон для погрузчика (снимается при монтаже)
Примечания заказчикаДополнительное оборудование
Встроенный блок питания Uвх___В, Uвых___В, Iвых___А С аккумулятором, емкость ___А ч Wi-Fi антенна, коммутатор или точка доступа Дистанционный контроль и управление системой по протоколам удаленного доступа
HTTP и SNMP по Ethernet или другим протоколам
Количество, шт.
Контактная информация
Организация: Почтовый адрес:Контактное лицо: Тел./факс: E-mail:
p. 325
ComponentsCable glands,
plugs, adapters
p. 393
304
GTG-SHKAF KSH/TERMO-BOX
Hea
ting
equi
pmen
t
• Temperature inside GTG-SHKAF cabinet is increased by an explosion-proof heater 600 W with an additional au-tomatic temperature control device.
• Heating element control and power input are carried out via explosion-proof boxes.
• Temperature inside the cabinet can be regulated by means of different thermostats or an automatic system on the base of a programmable logic controller.
• Inner cabinet walls are covered with a specialized layer of ultra-light heat-resistant metalized armored heat insulator for ensuring efficient thermal insulation, or an ad-ditional extrusion polymer foam coating is applied for ther-mal insulation increase.
MARKING
II Gb or III Db
III Db
1Ex d e IIC T3 Gb (for version /OBOGREV)
MINING EQUIPMENT MARKINGРН1, РН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244РОСС RU.EX01.B00004TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666
CODESGOST 12.2.007.0-75GOST 14254-96GOST R IEC 60079-0-2011GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.1-2002 (IEC 60079-1:1998)GOST 30852.8-2002Electrical Installation Code Ch. 7.3, Ch. 7.4TR CU 012/2011, TR CU 004/2011GOST 31441.1-2011 (EN 13463-1:2001)GOST 24754-2013GOST 30852.20-2002
TECHNICAL CHARACTERISTICS
Installation
Category II for gas subgroup IIA, IIB, IIC; zones 1, 2;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities
Relative air humidity
98%
Enclosure material
Low-carbon steel (for GTG-SHKAF-M enclosures)Stainless steel (for GTG-SHKAF-N enclosures)
Sealant
Silicone rubber (in cover groove)
Grounding
2 stainless steel ground clamps (inner and outer)
Thermal insulation
Low heat-conducting composite materials (without application of mineral wool)
Cable glands arrangement
As per customer’s specification
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
IP 5466
305
GTG-SHKAF KSH/TERMO-BOX
Hea
ting
equi
pmen
t
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Cable and pipe transits /KPG
Floor mounting on a frame /RAMA
Modular version as per customer’s layout /MODULNYI
Wall mounting /STENA
Material of enclosure stainless steel 08X18Н10 as per GOST 5632-72 (AISI 304) /N
Electrical heating /OBOGREV
Window /O
Nameplate with inscription as per customer’s specification /NADPIS «_»
Earthquake-resistant version /MSK-64
Indication of voltage presence on current-conducting terminals /IN
Non-explosion-proof general industrial version /PROM
OVERALL AND MOUNTING DIMENSIONS
Temperature sensor
GTG-PLASTINA
Temperature sensor
306
GTG-SHKAF KSH/TERMO-BOX
Hea
ting
equi
pmen
t
Cabinet enclosure type Dimensions, mmA B C
GTG-SHKAF-M-806021 800 600 210GTG-SHKAF-M-806025 800 600 250GTG-SHKAF-M-806030 800 600 300GTG-SHKAF-N-806030 800 600 300GTG-SHKAF-M-808030 800 800 300GTG-SHKAF-M-1006021 1000 600 210GTG-SHKAF-M-1006025 1000 600 250GTG-SHKAF-M-1006030 1000 600 300GTG-SHKAF-M-1008030 1000 800 300GTG-SHKAF-N-1008030 1000 800 300GTG-SHKAF-M-1206021 1200 600 210GTG-SHKAF-M-1206030 1200 600 300GTG-SHKAF-M-1208030 1200 800 300GTG-SHKAF-N-1208030 1200 800 300
М — low-carbon steel enclosures with a cover on hinges, cover fastening with a lockN — stainless steel enclosures with a cover on hinges, cover fastening with a lockOther enclosure size upon approval.
FORMATION OF MARKING
GTG-SHKAF – X – X – X / X – TU 3400-005-72453807-07
Device typeMaterial of enclosure: low-carbon steel — M; stainless steel — NEnclosure sizeNumber and type of cable glandsOptions, accessories and versions
Example of order: GTG-SHKAF-M-808030-8KNV2О(B)/RAMA – TU 3400-005-72453807-07.
Table of names matchingPrevious international name “ZAVOD GORELTEX” Co. Ltd.
TU 3400-005-72453807-07Previous international name “ZAVOD GORELTEX” Co. Ltd.
TU 3400-005-72453807-07Explosion-proof all-weather wall-mounted cabinets with thermal insulation
KSH/TERMO-BOX GTG-SHKAFKSH/TERMO-BOX-МPЗ-806021 GTG-SHKAF-M-806021KSH/TERMO-BOX-МPЗ-806025 GTG-SHKAF-M-806025KSH/TERMO-BOX-МPЗ-806030 GTG-SHKAF-M-806030KSH/TERMO-BOX-CPЗ-806030 GTG-SHKAF-N-806030KSH/TERMO-BOX-МPЗ-808030 GTG-SHKAF-M-808030KSH/TERMO-BOX-МPЗ-1006021 GTG-SHKAF-M-1006021KSH/TERMO-BOX-МPЗ-1006025 GTG-SHKAF-M-1006025KSH/TERMO-BOX-МPЗ-1006030 GTG-SHKAF-M-1006030KSH/TERMO-BOX-МPЗ-1008030 GTG-SHKAF-M-1008030KSH/TERMO-BOX-CPЗ-1008030 GTG-SHKAF-N-1008030KSH/TERMO-BOX-МPЗ-1206021 GTG-SHKAF-M-1206021KSH/TERMO-BOX-МPЗ-1206030 GTG-SHKAF-M-1206030KSH/TERMO-BOX-МPЗ-1208030 GTG-SHKAF-M-1208030KSH/TERMO-BOX-CPЗ-1208030 GTG-SHKAF-N-1208030
Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393
307
GTG-OSHA RETO-PLATE-HS-480W-T190
Hea
ting
equi
pmen
t
• GTG-OSHA are intended for maintenance of preset positive temperature in cabinets for control and measuring equipment, automation cabinets, and cabinets with thermal insulation.
• High operational reliability is guaranteed by the exclusion of temperature fluctuations exclusion or maintenance of required minimum temperature.
• Heating plates are used for prevention of equipment malfunctioning caused by current leakage on electric parts or other malfunctions which can occur due to corrosion of mechanical parts of installations and electric contacts caused by dew point occurrence.
• GTG-OSHA explosion-proof heaters are equipped with built-in thermostat that does not allow the heating plate temperature to rise above 190 °С.
• Heater design causes so called ‘fireplace effect’ that enables even heat distribution inside boxes and cabinets.
MARKING
1Ex e II T3 Gb X
1Ex s II T3 Gb
Ex tb IIIC T200°C Db X
MINING EQUIPMENT MARKINGРН1РН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247РОСС RU.EX01.B00002TC RU C -RU.МЛ02.B.00625Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)TU 3400-007-72453807-07
CODESGOST 14254-96 (IEC 529-89)GOST R IEC 60079-0-2011GOST 30852.0-2002 (IEC 60079-0: 1998)GOST 30852.8-2002GOST IEC 61241-1-1-2011GOST R IEC 62086-1-2003GOST 24754-2013TR CU 012/2011, TR CU 004/2011Electrical Installation Code Ch. 7.3, Ch. 7.4GOST 22782.3-77GOST 12.2.007.0-75GOST 30852.20-2002GOST R IEC 60079-31-2010
TECHNICAL CHARACTERISTICS
Installation
Category II for gas subgroup IIA, IIB, IIC; zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities
Supply voltage, V
~220 В (50/60 Hz)
Power, W
480
Current consumption, A
2
Power density, W/cm2
2
Maximum surface heating temperature, °С
190
Insulation resistance, MOhm
>100
Operating position in space
any
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
IP 6768
308
GTG-OSHA RETO-PLATE-HS-480W-T190
Hea
ting
equi
pmen
t
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Non-explosion-proof general industrial version /PROM
OVERALL AND MOUNTING DIMENSIONS
Silicone wires, length: L=1000 mm1.0 mm2 Wire in insulation
Temperature controllers
Model Type Heating temperature, °СDVG-TERMOSTAT2-0.-1.10
Fixed temperature7–13
DVG-TERMOSTAT2-0.4.15 12–18DVG-TERMOSTAT2-0.64.75 72–78
GTG-PT-0.120 Programmable temperature 0...120DVG-TERMOSTAT-M0.60 Manual setting 0...60DVG-TERMOSTAT-M0.80 0...80
FORMATION OF MARKING
GTG-OSHA – TU 3400-005-72453807-07Device type
Example of order: GTG-OSHA – TU 3400-005-72453807-07.
309
GTG-PLASTINA2 RETO-PLATE-CAVO-150W/300W/600W
Hea
ting
equi
pmen
t
• GTG-PLASTINA2 explosion-proof heating plates are intended for heating of flat and curved surfaces, such as reservoirs with petroleum products, containers, pipes surfaces, reservoirs with lubricants, heating of materials being refined, technological structures, hydraulic drives and joints of power devices etc.
• Explosion-proof heating plates are manufactured from special heat-resistant rubber and are equipped with a built-in thermostat that does not allow heating temperature to rise above 190 °С. It is recommended to apply PG-TERMOKLEY sealant or heat-conducting PG-TERMOPASTA paste for better transmission of thermal energy.
• GTG-PLASTINA2 explosion-proof heating plates shall be fastened directly to the heated surfaces of technological objects and structures and are intended for operation in the harshest operating conditions, where resistance of the equipment to wide temperature ranges, moisture and dust is required.
MARKING
1Ex e II T3 Gb
Ex tb IIIC T200°С Db
1Ex e II T3 Gb X
Ex tb IIIC T200°С Db X
MINING EQUIPMENT MARKINGРН1РН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247РОСС RU.EX01.B00002TC RU C -RU.МЛ02.B.00625Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)TU 3400-007-72453807-07
CODESGOST R IEC 60079-0-2011GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST R IEC 62086-1-2003GOST 30852.8-2002TR CU 012/2011, TR CU 004/2011GOST IEC 61241-1-1-2011GOST 24754-2013Electrical Installation Code Ch. 7.3, Ch. 7.4GOST 12.2.007.0-75GOST 30852.20-2002GOST R IEC 60079-31-2010
TECHNICAL CHARACTERISTICS
Installation
Category II for gas subgroup IIA, IIB, IIC; zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities
Supply voltage, V
~220 В (50/60 Hz)
Power, W
150, 300, 600
Power density, W/cm2
0.3
Maximum surface heating temperature, °С
190
Insulation resistance, MOhm
>100
Operating position in space
any
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Non-explosion-proof general industrial version /PROM
67IP
310
GTG-PLASTINA2 RETO-PLATE-CAVO-150W/300W/600W
Hea
ting
equi
pmen
t
OVERALL AND MOUNTING DIMENSIONS
600
Wire 1.0 mm2 in insulation
BraidingProtective layer
Silicone wires
Model Size A, mm Size B, mm Power, W Power density, W/cm2
GTG-PLASTINA2-150/T190 220 220 150 0,31GTG-PLASTINA2-300/T190 305 305 300 0,32GTG-PLASTINA2-600/T190 305 610 600 0,30
FORMATION OF MARKING
GTG-PLASTINA2 – X / Т190 / X – TU 3400-007-72453807-07Device typePower, W: 150; 300; 600Options, accessories and versions
Example of order: GTG-PLASTINA2-300/T190 – TU 3400-007-72453807-07
311
GTG-PLASTINA1 RETO-PLATE-T190
Hea
ting
equi
pmen
t
• GTG-PLASTINA1 explosion-proof heating plates are intended for heating of flat and curved surfaces. The plates shall be fastened directly to the heated surfaces of technological objects and structures and are intended for operation in the harshest operating conditions, where resistance of the equipment to wide temperature ranges, moisture and dust is required.
• Explosion-proof heating plates are manufactured from special heat-resistant rubber, have earthing grid, an explosion-proof gland for power connection and are equipped with a built-in thermostat that does not allow heating temperature to rise above 190 °С.
• It is recommended to apply PG-TERMOKLEY sealant or heat-conducting PG-TERMOPASTA paste for better transmission of thermal energy.
MARKING
1Ex e II T3 Gb X
Ex tb IIIC T200°С Db X
MINING EQUIPMENT MARKINGРН1РН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247РОСС RU.EX01.B00002TC RU C -RU.МЛ02.B.00625Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)TU 3400-007-72453807-07
CODESGOST R IEC 60079-0-2011GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST R IEC 62086-1-2003GOST 30852.8-2002TR CU 012/2011, TR CU 012/2011GOST IEC 61241-1-1-2011GOST 24754-2013Electrical Installation Code Ch. 7.3, Ch. 7.4GOST 12.2.007.0-75GOST 30852.20-2002GOST R IEC 60079-31-2010
TECHNICAL CHARACTERISTICS
Installation
Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities
Supply voltage, V
~220 (50/60 Hz)
Power, W
300, 600, 1200
Maximum surface heating temperature, °С
190
Insulation resistance, MOhm
>100
Operating position in space
any
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Non-explosion-proof general industrial version /PROM
66IP
312
GTG-PLASTINA1 RETO-PLATE-T190
Hea
ting
equi
pmen
t
OVERALL AND MOUNTING DIMENSIONS
Terminal box
Model Mounting dimensions, mm Power, W Power density, W/cm2
A BGTG-PLASTINA1-300/T190 305 305 300 0,32GTG-PLASTINA1-600/T190 610 305 600 0,28
GTG-PLASTINA1-1200/T190 610 610 1200 0,32
GTG-PLASTINA1 heating plates can be completed with temperature control devices if heating below 190°С is required.
Temperature controllersModel Type Heating temperature, °С
DVG-TERMOSTAT2-0.-1.10Fixed temperature
7–13DVG-TERMOSTAT2-0.4.15 12–18
DVG-TERMOSTAT2-0.64.75 72–78GTG-PT-0.120 Programmable temperature 0...120
DVG-TERMOSTAT-M0.60 Manual setting 0...60DVG-TERMOSTAT-M0.80 0...80
FORMATION OF MARKING
GTG-PLASTINA1 – X / Т190 / X – TU 3400-007-72453807-07Device typePower, W: 300; 600; 1200Options, accessories and versions
Example of order: GTG-PLASTINA1-600/T190 – TU 3400-007-72453807-07.
Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393
313
GTG-KABEL1 RETO-CORD/S
Hea
ting
equi
pmen
t
• Heating material shrinks at low temperatures creating lots of carbon current-conducting paths and reducing electrical resistance. When electric current flows via heating element, a thermal energy output occurs.
• Heating element material expands in warmer sections of the explosion-proof heating cable, reducing number of current-conducting paths. Electrical resistance of heating element material increases, resulting in a significant thermal energy output reduction.
• Expansion of material of heating element in hot spots of the heating cable almost entirely tears current-conducting paths. Along with that, electric resistance of material becomes very high, which leads to significant reduction of heat energy output.
MARKING
1Ex e II T4...T2 Gb X
Ex tb IIIC T135°С...T300°С Db X
MINING EQUIPMENT MARKINGРН1, РН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247РОСС RU.EX01.B00002TC RU C -RU.МЛ02.B.00625TU 3400-007-72453807-07
CODESGOST R IEC 60079-0-2011GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST R IEC 62086-1-2003GOST 30852.8-2002TR CU 012/2011, TR CU 004/2011GOST IEC 61241-1-1-2011GOST 24754-2013Electrical Installation Code Ch. 7.3, Ch. 7.4GOST 12.2.007.0-75GOST 30852.20-2002GOST R IEC 60079-31-2010
TECHNICAL CHARACTERISTICS
Installation
Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities
Supply voltage, V
~220 (50/60 Hz)
Operating position in space
any
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Non-explosion-proof general industrial version /PROM
Cable element for heating cable end termination /GTG-ZGK
68IP180
105135
314
GTG-KABEL1 RETO-CORD/S
Hea
ting
equi
pmen
t
• Low-temperature low-power flexible heating cable with temperature self-regulation
Heating cables W/mMaximum main-
tained operating temperature t °C
Maximum cable length through the circuit breaker, during switching on at minimum operating
temperature, meters Max t °C
16А 20А 25А 32А 40А
Explosion-proof reinforced low-temperature type GTG-KABEL1-65 with outer fluoropolymer insulation
10 65°C 128 160 200 — — 70°C15 88 110 137 176 —
DIAGRAM OF DEPENDENCE OF LINEAR POWER ON TEMPERATURE GTG-KABEL1-65-10, GTG-KABEL1-65-15
Temperature, °C
Line
ar p
ower
, W/m
10 W
10 20 30 40 50 60
30
20
10
0
15 W
• Low-temperature high-power flexible heating cable with temperature self-regulation
Heating cables W/mMaximum main-
tained operating temperature t °C
Maximum cable length through the circuit breaker, during switching on at minimum operating
temperature, meters Max t °C
16А 20А 25А 32А 40А
Explosion-proof reinforced low-temperature type GTG-KABEL1-65 with outer fluoropolymer insulation
30 65°C 44 55 69 88 110 70°C50 26 33 41 53 66
DIAGRAM OF DEPENDENCE OF LINEAR POWER ON TEMPERATURE GTG-KABEL1-65-30, GTG-KABEL1-65-50
Temperature, °C
Line
ar p
ower
, W/m
50 W
30 W
10 20 30 40 50 60
50
40
30
20
10
0
Self-regulating heating cable structure:1. Current-conducting stranded tin-plated copper cores.2. Thremoresistive element. 3. Internal insulation for provision of dielectric strength, moisture tightness, protection against impact loads and abrasion,
as well as protection against chemical exposure for heat-producing matrix. 4. Outer insulation. 5. Copper tin-plated screen. 6. Fluoropolymer outer protective sheath is applied in conditions of increased humidity as well as under the exposure of
organic substances and solvents or other aggressive substances in common areas or in areas classified as hazardous (not applied for /PROM version).
315
GTG-KABEL1 RETO-CORD/S
Hea
ting
equi
pmen
t
• Mid-temperature high-power flexible heating cable with temperature self-regulation
Heating cables W/mMaximum main-
tained operating temperature t °C
Maximum cable length through the circuit breaker, during switching on at minimum operating
temperature, meters Max t °C
16 А 20 А 25 А 32 А 40 АExplosion-proof reinforced low-temperature type GTG-KABEL1-105 with outer reinforced fluoropolymer insulation 50 105°C 32 40 50 65 80 120°C
DIAGRAM OF DEPENDENCE OF LINEAR POWER ON TEMPERATURE GTG-KABEL1-105-50
50 W
Temperature, °C
Line
ar p
ower
, W/m
• High-temperature high-power flexible heating cable with temperature self-regulation
Heating cables W/mMaximum main-
tained operating temperature t °C
Maximum cable length through the circuit breaker, during switching on at minimum operating
temperature, meters Max t °C
16 А 20 А 25 А 32 А 40 АExplosion-proof reinforced low-temperature type GTG-KABEL1-130 with outer reinforced fluoropolymer insulation 50 130°C 35 45 55 70 90 140°C
DIAGRAM OF DEPENDENCE OF LINEAR POWER ON TEMPERATURE GTG-KABEL1-130-50
70
60
50
40
30
20
10
010 20 30 40 50 60 70 80 90 100 110 120 (°C)
50 W
Temperature, °C
Line
ar p
ower
, W/m
FORMATION OF MARKING
GTG-KABEL1 – X – X – X / X – TU 3400-007-72453807-07
Device typeMaximum maintained operating temperature t °C: 65; 105; 130Power, W: 10; 15; 30; 50Length in metersOptions, accessories and versions
Example of order: GTG-KABEL1-65-15-100 – TU 3400-007-72453807-07.
316
GTG-ZGK MC-CORD
Hea
ting
equi
pmen
t
• Bare ends require termination within the process of heating cable installation in order to ensure safe operation. Hazardous atmosphere conditions require special meas-ures for explosion protection provision.
• GTG-ZGK cable element is intended for explo-sion-proof end termination of the heating cable. Inner vol-ume of the cable element shall be filled with compound for increased degree of explosion protection. For indication of voltage presence on current-conducting wires GTG-ZGK modification with a built-in LED indicator can be provided.
MARKING
Ex d IIC Gb U
MINING EQUIPMENT MARKINGРН1, РН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247РОСС RU.EX01.B00002TU 3400-005-72453807-07
CODESGOST R IEC 60079-0-2011GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.1-2002 (IEC 60079-1:1998)Electrical Installation Code Ch. 7.3, Ch. 7.4TR CU 012/2011GOST 12.2.007.0-75GOST 30852.20-2002GOST 24754-2013
TECHNICAL CHARACTERISTICS
Installation
Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities
Mass, kg
0,1
Enclosure material
Galvanized steel: ONickel-plated brass, resistant to hydrogen sulfide and hydrochloric acid vapors and salt spray: NKStainless steel: N
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Indication of voltage presence on current-conducting wires /IN
66IP
317
GTG-ZGK MC-CORD
Hea
ting
equi
pmen
t
GTG-ZGK WITHOUT INDICATION
1) Plug2) GTG-KABEL1 heating cable3) PG-COMPOUND compound4) PG-REZBA-F sealant5) Special heatproof silicone sealant
Thread code Thread type Size of the crimped cable1 1/2” Rc 12 x 7,5
2 3/4” Rc
12 x 7,515 x 8
2 x 12 x 7,52 x 15 x 8
SEALING RUBBERS FOR HEATING CABLES
FORMATION OF MARKING
GTG-ZGK – X – X – X / X – TU 3400-007-72453807-07Device typeCode of typical size of threadTypical size of crimped cableEnclosure material: galvanized steel — О; Nickel-plated brass – NK; stainless steel – N Options, accessories and versions
Example of order: GTG-ZGK2-15x8-N – TU 3400-005-72453807-07.
318
GTG-RADIATOR RETO-PLATE-RADIATOR/M
Hea
ting
equi
pmen
t
• GTG-RADIATOR explosion-proof plate heating ele-ments are intended for heating and maintenance of pos-itive preset temperature in technological rooms, automa-tion cabinets, units with control and measuring and other equipment which requires positive temperature for normal operation.
• Plate heaters allow to evenly heat air in confined area; they are explosion-proof and reliable heating elements which exclude direct contact of heating elements with in-stalled equipment. Flat silicone explosion-proof heating el-ement is fastened to the aluminum plate in the protective metal housing with perforation. More efficient heating is reached by an additional special layer of heat insulation in the point where the plate is fastened to the housing.
• GTG-RADIATOR heating element is a vibration-resist-ant and corrosion-resistant silicone plate. The heater does not accumulate dust due to flat structure of the heating element.
MARKING
1Ex e II T3 Gb X
Ex tb IIIC T200°С Db X
MINING EQUIPMENT MARKINGРН1, РН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247TC RU C -RU.МЛ02.B.00625РОСС RU.EX01.B00002Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)TU 3400-007-72453807-07
CODESGOST R IEC 60079-0-2011GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST R IEC 62086-1-2003GOST 30852.8-2002TR CU 012/2011, TR CU 004/2011GOST IEC 61241-1-1-2011GOST 24754-2013Electrical Installation Code Ch. 7.3, Ch. 7.4GOST 12.2.007.0-75GOST 30852.20-2002GOST R IEC 60079-31-2010
TECHNICAL CHARACTERISTICS
Installation
Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities
Supply voltage, V
~220 V (50/60 Hz)
Power, W
600, 1200
Electrical diagram
Direct connection to L, N, PE terminals with 4mm2 cross-section
Mass, kg
10
Thread on connecting holes
Rc ½” taper pipe
Operating position in space
any
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Enclosure temperature limitation /100
Nameplate with inscription as per customer’s specification /NADPIS «_»
OVERALL AND MOUNTING DIMENSIONS GTG-RADIATOR-600
66IP
319
GTG-RADIATOR RETO-PLATE-RADIATOR/M
Hea
ting
equi
pmen
t
4 holes ø7
GTG-RADIATOR-1200
RETO-PLATE-RADIATOR/SA
60ТС RU C-RU.ГБ05.В.00394 / ТС RU C-RU.ГБ05.В.00432
Tокр - °C + °C IP
1200
60
техническая поддержка +7 800 100 100 4,
2ExeIIT3 / 1Ex e II T3 Gb X
R
ОТКЛЮЧИВ ОТ СЕТИ
R
PВ
ОТКРЫВАТЬ
НАНИО "ЦСВЭ"
220n n
66
S.N.fU Вт 50 Гц
810
392
192
252
712 4 holes ø7
FORMATION OF MARKING
GTG-RADIATOR – X – X / X – TU 3400-007-72453807-07Device typePower, W: 600, 1200Dimension type of the cable glandOptions, accessories and versions
Example of order: GTG-RADIATOR-1200-KNV1N – TU 3400-007-72453807-07.
Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393
320
GTG-PT SA-TERMOSTAT-D
Hea
ting
equi
pmen
t
• Option of actuation temperature setting by an opera-tor within the range from -40°C to +110°C;
• Option of setting temperature difference between Tactuation and Treturn within the range from 0°C to 10°C from the value of actuation temperature;
• Two electrically independent changeover contacts;• Option of connection of controlled objects with cur-
rent consumption up to 16 A and alternating voltage up to 250 V;
• Option of remote sensor installation at a distance of up to 30 meters to the device;
• Small sizes of the sensor, simple installation; • Operation of the product at ambient temperature with-
in the range from -60°C to +60°C;• Temperature sensor state control and switching to
emergency mode in case of signal absence; • Simultaneous control of up to 4 external devices; • Simple remote temperature measurement in the se-
lected environment.
MARKING
1Ex d e [ib] IIC T5 Gb (for GTG-PT control unit)
Ex d [ib] IIC U (for temperature sensor)
MINING EQUIPMENT MARKINGРН1, РН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244РОСС RU.EX01.B00004Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666
CODESGOST 12.2.007.0-75GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.1-2002 (IEC 60079-1:1998)GOST 30852.8-2002GOST 30852.10-2002 (IEC 60079-11:1999)GOST 14254-96 (IEC 529-89)Electrical Installation Code Ch. 7.3, Ch. 7.4TR CU 012/2011GOST 30852.20-2002GOST 24754-2013
TECHNICAL CHARACTERISTICS
Installation
Category II for gas subgroup IIA, IIB, IIC; zones 1, 2;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities
Operating voltage, V
~220 V (50/60 Hz)
Alternating current consumption
20 mA
Maximum switched alternating current
16 А
Maximum switched alternating voltage
250 V
Maximum switched direct current
16 А
Maximum switched direct voltage
220 V
Mass
up to 5 kg
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
66IP
321
GTG-PT SA-TERMOSTAT-D
Hea
ting
equi
pmen
t
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Version with additional mounting plates /PLANKA
Increase measured temperature range -40°C…+125°C; /T125
Increased switched current ( X – value of the current, A) /X
Special version of sensor housing as per customer’s specification /KD
OVERALL AND MOUNTING DIMENSIONS
MOUNTING DIMENSIONS OF GTG-PT IN STANDARD VERSION
174
22
4,5
27
6
18
2
125,5 135
R3,3
MOUNTING DIMENSIONS OF GTG-PT/PLANKA IN A VERSION WITH ADDITIONAL MOUNTING PLATES
64
175
R4,5
322
GTG-PT SA-TERMOSTAT-D
Hea
ting
equi
pmen
t
EXPLOSION-PROOF TEMPERATURE SENSOR
21
13
M12x1.5 – 6g
FORMATION OF MARKING
GTG-PT – X – X / X – TU 3400-007-72453807-07Device nameLength of temperature sensor’s cable in meters (maximum length 30 m)Number and type of cable glandsOptions, accessories and versions
Example of order: GTG-PT-10-2KNV20/PLANKA – TU 3400-005-72453807-07.
Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393
323
GTG-VK2 SA-A2CORD
Hea
ting
equi
pmen
t
• Application of GTG-VK2 allows to simplify installation and excludes heat-ing cable damage during its input under heat insulation, as well as it allows to splice ends of the heating cable for T-shaped branches.
• GTG-VK2 are applied for all types of GTG heating equipment and cables of third party manufacturers.
• Design of OKT-2 supporting brackets enables convenient mounting on the pipe with round cross-section. The box shall be fastened to the pipe with a metal fastening clamp which is included in the set. The clamp ensures relia-bility of the grounding circuit between the pipe and the enclosure.
• Several supporting brackets can be installed on the enclosure upon cus-tomer’s request for the connection of more than 3 heating elements; arrange-ment of terminal blocks inside the box can be amended.
MARKING
1Ex e II T6...T4 Gb
Ex tb IIIC T70°С...T135°С Db
MINING EQUIPMENT MARKINGРН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244TC RU C -RU.МЛ02.B.00626РОСС RU.МШ06.Н00147TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666
CODESGOST R IEC 60079-0-2011GOST 12.2.007.0-75GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.8-2002TR CU 012/2011, TR CU 004/2011GOST IEC 61241-1-1-2011Electrical Installation Code Ch. 7.3, Ch. 7.4OD 5.2-093-2004GOST 30852.20-2002GOST 24754-2013GOST R IEC 60079-31-2010
TECHNICAL CHARACTERISTICS
Installation
Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Non-hazardous areas of ground facilities and open sites;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities
Maximum voltage, V
800
Maximum current, A
175
Mass, kg
3
Size of connected heating cable, mm
up to 17
Connected power cable diameter and dimension type of the cable gland
from 6 mm to 12 mm for KNV1 cable gland (by default)from 12 mm to 18 mm for KNV2 cable glandfrom 6 mm to 12 mm for KOV1 cable glandfrom 12 mm to 18 mm for KOV2 cable glandother cable gland upon customer’s request
Bracket height
H=150 mm (other height upon customer’s request with order from 1000 pcs.)
Grounding
2 stainless steel ground clamps (inner and outer)
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
IP 6667
HOLOD
324
GTG-VK2 SA-A2CORD
Hea
ting
equi
pmen
t
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Non-explosion-proof version /PROM
Indication of voltage presence on current-conducting wires /IN
Other bracket height (with order from 1000 pcs.) /H (height in millimeters)
Round heating cable /KGK
Option of temperature sensor connection /PKT
U-shaped base for increase of bracket fixation.Fastening to the pipe with 2 clamps.Application of U-shaped base does not influence bracket height
/P
OVERALL AND MOUNTING DIMENSIONS
SEALING RUBBER FOR HEATING CABLE FOR GTG-VK2
Enclosure typeDimensions Maximum recommended number of terminals per wire cross-section, mm2
А B C H 2,5 4 6 10
GTG-VK2-111109 112 112 91 150 14 10 9 7
GTG-VK2-171109 172 112 91 150 23 17 14 12
GTG-VK2-141410 149,5 149,5 107 150 32 22 19 15
FORMATION OF MARKING
GTG-VK2 – X – X – X – X / X – TU 3400-005-72453807-07Product nameEnclosure size codeDiameter of a heated pipeType of installed terminalsNumber and dimension type of cable glandsOptions, accessories and versions
Example of order: GTG-VK2-111109-100-4С2-1KNV1(А)-1KOV1(B) – TU 3400-005-72453807-07.
Table of names matchingPrevious international name “ZAVOD GORELTEX” Co. Ltd.
TU 3400-005-72453807-07 The Customs Union name “ZAVOD GORELTEX” Co. Ltd.
TU 3400-005-72453807-07 SA-A2CORD GTG-VK2
SA-A2CORD /SA11 GTG-VK2-111109SA-A2CORD /SA14 GTG-VK2-141410SA-A2CORD /SA20 GTG-VK2-171109
Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393
325
Datasheet
Hea
ting
equi
pmen
t
GORELTEX DATASHEET FOR GTG, UVG (KSH) EXPLOSION-PROOF AND FIREPROOF THERMO CABINETS (HOUSINGS)Maximum allowed outer
dimensions of the cabinetH = _______mm W = _______mmD = _______mm
Maximum allowed weight of the cabinet (housing) _______ kg
Material of enclosure Material of heat insulation
Low-carbon steel with varnish-and-paint coating (heat transfer coefficient 5,5 W/m2K) Stainless steel grade 03Х18Н10 (AISI304) (heat transfer coefficient 5,5 W/m2K) Impact-resistant seamless inert polymer (heat transfer coefficient 3,5 W/m2K) Modified corrosion-resistant aluminum-silicon alloy (heat transfer coefficient 12 W/m2K)
Without thermal insulation Metalized armored polyester Incombustible extrusion polymer foam
Method of fastening
Wall/RAMA mounting Concrete base mounting Floor mounting
Height of the base ______ mm
Sea platform mounting Dismountable installation on
a pipe (horizontal or vertical) Support mounting
Installation in the area
Group of mixture: IIА IIВ IIС IIICTemperature class: Т1 Т2 Т3 Т4 Т5 Т6Installation area: Zone 0 Zone 1 Zone 2
Non-hazardous fire-dangerous area RN
Application Open area installation NF1 Sea platform of vessel installation MU1 Installation in a non-heated space Underground installation Installation in a heated space
Geographic point of cabinet installation (region, nearest town) or ambient temperature
from –____ °С to +____ °С
Temperature extremesEquipment/carrier loss power
(self-heating) inside the cabinet (housing)
Place for customer’s drawing with approximate arrangement of
assemplies and points for their fastening
Lowest ambient t in the installation area ____°СMax. ambient t in the installation area ____°СRequired inner t ____°С or maintained t in the cabinet: from ____°С to ____°С
Minimum_____W Maximum _____WConstant _____WMedium _____W
Cabinet (housing) filling coefficient Required inner space____ (0 – empty cabinet, 10 – entire cabinet volume is filled with equipment) H=___mm W=___mm D=___mm
Cabinet (housing) climatic system type Required type of equipment protection against aggressive atmospheres
Passive With electrical heating with heat extraction – semi-conductive cooler IP66/68 with heat extraction – external fan blowing IP55 with heat extraction – fan for airing and cooling IP05
Electric supply voltage ______V АС DC
Hermetic enclosure, IP66 Excess pressure maintenance (low consumption of dry air) IP67 Hermetic enclosure, resistant to flooding IP68 Purging with dry air (high consumption of dry air) IP66
Anti-vandal protection Lighting
4 mm steel enclosure Lock in the door Sound alarm Remote video surveillance Door security alarm with reed sensor Switch Anti-theft fastening (of various design depending on the method of installation)
Light fixture for internal lighting Door limit switch Masking light fixture for internal lighting Option of padlock installation
Sound proofing Devices for customer’s equipment installation
Lining with sound-proof material Internal lining – perforated panels with round holes in side walls for a self-driving screw for further fastening of mounting elements
Door opening angle 105° Fastener for the arrangement of units in 19” standard
Cable and pipe entryCable glands for cables
Non-armored Armored/braided Flexible metal
hoseCorrugated
polymer Wiring in pipe d pcs.
123
Cable glands for cables
Steel pipe Steel pipe in heat insulation
Plastic pipe
Copper pipe
Rubber hose
Flexible metal hose d pcs.
123
Transits for cables/pipes H = ___ mm W = ___mm H = ___ mm W = ___ mm
Customer’s equipment fire protection
Heat detector Flame detector Gaseous fire suppression stand-alone system Door sealant – STOP FIRE
Devices for delivery and installation
Transport eye bolts for installation with a crane Placement on a pallet for a forklift (removed during installation)
Customer’s notesAdditional equipment
Built-in power supply unit Uinp___V, Uout___V, Iout___A With accumulator, capacity___A h Wi-Fi antenna, switching unit or access point Remote control and system control under remote access protocols HTTP and SNMP Ethernet
or other protocols.
Quantity, pcs.
Contact detailsCompany: Postal address:Contact person: Tel./fax: E-mail:
“ZAVOD GORELTEX” Co. Ltd.