heat pump water heater - residentialex300-1118 printed in u.s.a. model number approx. shipping...
TRANSCRIPT
Heat Pump Water Heater - Residential
Heat Pump Model Features:� A+ ErP Efficiency Rating.� IEC Compliant.� COP - 4.4—(based on A20/W10-55).� Operating Air Temperature Range: 7°C to 40°C (45°F to 104°F) for Heat
Pump—(Unit operates in Standard/Electric Mode outside of this range).� Electronic control with mechanical buttons and LED indicator enables:
-- Switch on/off.-- Setting water temperature ranging from 10°C (50°F) to 75°C (167°F).-- Display of water temperature in the tank.-- Automatic anti-Legionella control system.-- Fault/error diagnostics.
� Operating Modes Offer Flexibility.-- Heat Pump (Only) Mode—Maximizes consumer savings. The most energy-
efficient mode as it only utilizes the heat pump.-- Turbo mode—Combines the heat pump and heating element to quickly
recover the hot water in the tank.-- Back-up Operating Mode—If the inlet air temperature is lower than 7°C
(45°F) or higher than 40°C (104°F), the heat pump switches to backup operating mode, utilizing the integrated heating element. When heat pump operating conditions are met, the unit automatically switches back to heat pump mode.
� Turbo recovery to the setpoint temperature with simultaneous heat pump and element operation.
� High-quality Steel Tank Protected with Enamelled Coating and Multiple Magnesium Anode Rods.
� Quiet Operation—Operating sound level of approximately 59 DBA.� Maximum Temperature Ranges—65°C (149°F) with heat pump or up to 75°C
(167°F) with supplemental heating element.� 2 kW Dry Element as an Additional or Spare Source of Water Heating.� High-quality PU Insulation for Lower Heat Losses. � Water Connections—G 3/4 for 200 liter models and G 1 for 300 liter models.
* Indoor installation only
Photo is ofModel BWHP200
5-Year Limited Tank Warranty / 1-Year Limited Warranty on Component Parts.For more information on warranty, please visit www.bradfordwhite.com
EX300-1118
FEATURING:
IEC
©2018, Bradford White Corporation. All rights reserved.
International: Telephone 1-215-641-9400 n Email [email protected] / www.bradfordwhite.comAmbler, PA
Printed in U.S.A.EX300-1118
ModelNumber
Approx.ShippingWeight
kg.
BJacketDia.
mm.
AFloor to
Topof
Heatermm.Liters
Capacity
BWHP200BWHP200CBWHP300BWHP300C
200190285275
97114130147
1860186019601960
DFloor to
ColdWaterInletmm.
155155165165
EFloor to
HotWaterOutletmm.
1265126512751275
FFloor toRecirc.Conn.
mm.
905905905905
GFloor to
HeatExch.Inletmm.
N/A733N/A760
HFloor to
HeatExch.Outletmm.
N/A243N/A270
IFloor to
CondensateConn.
mm.
1490149015251525
570570670670
CDepth
mm.
585585685685
Heat Pump Water Heater - Residential
GeneralAll models are manufactured in accordance with IEC Standards. All models certified up to 7 bar (102 PSI) working pressure.Models are not available in USA or Canada.Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
All models are manufactured in accordance with IEC Standards. All models certified up to 7 bar (102 PSI) working pressure.(1) by air inlet temperature of 15°C (59°F), 74% humidity and 10°C (50°F) water on beginning heated up till 55°C (131°F) regarding to EN16147.(2) by air inlet temperature of 20°C (68°F), 58% humidity and 10°C (50°F) water on beginning heated up till 55°C (131°F) regarding to EN16147 and EU Regulation 812/2013.(3) Heating of sanitary water from 10°C (50°F) to 45°C (113°F) at inlet temperature of heat transfer fluid 80°C (176°F) and flow rate 3000 l/h.(4) EN 12102:2013.
MODEL Declared load profile Energy efficiency class (2)Energy efficiency ŋwh (2)AEC annual electricity consumption _ACC (2)Daily electricity consumption Qelec_ACC (2)Thermostat temperature settingsSound power level LWA, indoors (4)Storage volume V Mixed water at 40°C V40 (2)TECHNICAL CHARACTERISTICS Heating up Period A15 / W10-55 (1)Heating up Period A20 / W10-55 (2)Heating up energy input A15 / W10-55 (1)Heating up energy input A20 / W10-55 (2)Energy consumption with profile A15 / W10-55 (1)Energy consumption with profile A20 / W10-55 (2)COPDHW (A15 / W10-55) EN 16147 (1)COPDHW (A20 / W10-55) EN 16147 (2)Standby power input according to EN16147 (2)Refrigerant, R134aQuantity of refrigerant Working range - air temparatureELECTRICAL SPECIFICATIONSNominal electrical power - compressor Maximum power consumption Voltage/FrequencyProtectionSTORAGE TANKEnamelled steel / Protection Mg anodeWorking pressureMAXIMUM TEMPERATUREHot water tank_ heat pump Hot water tank_ electric heater Hot water tank_heat exchanger DIMENSIONS AND CONNECTIONSHeight Width Depth Average thickness of insulationConnections to the watter supply networkConnections to the heat exchangerMax working pressure heat exchangerHeat exchanger surface bottom /topHeat exchanger volume bottom /topExchange power in continuous mode (max. coil output) (3)Continous output ΔT=35K (3)Net/Gross/with waterTRANSPORT DATAPackaging dimensions
Unit
% kWhkWh°C
dB(A)ll
h:min h:minkWhkWhkWhkWh
W
kg°C
WW
V/Hz
bar
°C °C °C
mm mm mmmm
Mpa (bar) m2
lkW
l/hour kg
mm
BWHP200L
A+ 177.6576
2.70955
58.3200.0275
8:077:192.252.053.012.723.94.315
GWP 14300.950
+7 / +40
3502350
230/50 IP21
+/+
7 6575 -
186057058560
G 3/4 - - - - - -
85/97/285
760x680x2060
BWHP200CL
A+ 177.3578
2.71955
58.3190.0260
7:436:592.141.953.052.733.94.316
GWP 14300.950
+7 / +40
3502350
230/50 IP21
+/+ 7
657595
186057058560
G 3/4G 1
1,2 (12)1,1/-
730.3745
102/114/292
760x680x2060
BWHP300XLA+
179.2935
4.3525559
285.0395
8:157:143.323.144.744.364.04.417
GWP 14301.100
+7 / +40
4902490
230/50 IP21
+/+
7 6575 -
196067068567G 1 - - - - - -
118/130/403
760x760x2160
BWHP300CXLA+
178.9936
4.3625559
275.0380
7:556:573.183.014.774.374.04.418
GWP 14301.100
+7 / +40
4902490
230/50 IP21
+/+ 7
657595
196067068567G 1G 1
1,2 (12)1,1/-
729.1715
135/147/410
760x760x2160
0,2 m
I
B
D
C
A
EF
G
H