head to end of alan higgs way added - coventry · tel: 0121 475 0234 fax 0121 475 2027...

5

Upload: others

Post on 08-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: head to end of Alan Higgs Way added - Coventry · Tel: 0121 475 0234 Fax 0121 475 2027 admin@philjonesassociates.co.uk Seven House, High Street, Longbridge, Birmingham, B31 2UQ File:
Page 2: head to end of Alan Higgs Way added - Coventry · Tel: 0121 475 0234 Fax 0121 475 2027 admin@philjonesassociates.co.uk Seven House, High Street, Longbridge, Birmingham, B31 2UQ File:

Potential Primary Vehicular Access

Point

Shared Pedestrian/ Cycle/

Emergency Link

Proposed Residential Development

LEGEND

Potential Pedestrian Access Point

Proposed Garden Zones

N

20

50m

0

10

40

30

Public Open Space

Existing Tree/ Hedgerow Planting

Proposed Tree/ Hedgerow Planting

Proposed Area for Formal Play

Proposed Orchard Planting

Indicative Attenuation Ponds/ Drainage

Public Right of Way

Proposed Informal Pedestrian Route

Proposed Pedestrian/ Cycle link to

Tile Hill Station

The scaling of this drawing cannot be assured

Revision

Date Drn Ckd

A

B

C

D

E

F

G

Updated in accordance with updated

technical inputs

Location of access points updated

Updated to reflect latest access drawings,

red line boundary and utility easements

Updated following consultant comments

Redline boundary updated, and turning

head to end of Alan Higgs Way added

Plan updated following comments from GVA

Amendments made to ped/ cycle route

01.06.16

06.06.16

22.06.16

24.06.16

11.07.16

11.07.16

11.07.17

EMB

EMB

EMB

EMB

CDB

EMB

EMB

CDB

CDB

CDB

CDB

JdH

CDB

CDB

ScaleDate

RevisionProject No Drawing No

Drawing Title

Project

Planning ● Master Planning & Urban Design ● Architecture ●

Landscape Planning & Design ● Environmental Planning ●

Graphic Communication ● Public Engagement ● Research

Offices at Bristol Cambridge Cardiff Ebbsfleet Edinburgh Leeds

London Manchester Newcastle Reading Birmingham Southampton

J:\25000 - 25999\25400 - 25499\25497 - Cromwell Lane, Coventry\A4 - Dwgs & Registers\Master Planning\Drawings\25497 9301 Concept Plan Rev G.dwg - A1

Check byDrawn by

bartonwillmore.co.uk

Certificate FS 29637

25947

CROMWELL LANE

COVENTRY

9301

CONCEPT PLAN

20.05.161:1250 @A1

G

EMB CDB

Page 3: head to end of Alan Higgs Way added - Coventry · Tel: 0121 475 0234 Fax 0121 475 2027 admin@philjonesassociates.co.uk Seven House, High Street, Longbridge, Birmingham, B31 2UQ File:

912

75

94

CLOSE

COLEBY

CR

OM

WE

LL L

AN

E

67

14

83

80

93

87

46

103

97

79

16

86

4

12

Surgery

50

89

63

CHARTER AVENUE

2.4

x43m

viz

i

2.4

x43m

viz

i

St St

St

St

St

St

St

St

Sv

Sv

SvSv

Sv

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Sp

Sp

Sp

TCL:

TCL:

TCL:

Post

Post

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Fh

Fh

Gas

Bus

Bolla

rds

Bo

ICU

ICU

GH2B117.464

GH2C116.179

GH2D114.316

117.62

117.70

120.47

123.05

120.58

123.29

120.62

119.19

123.64

124.49

121.75

120.10

119.21

118.38

122.88

118.17

119.63

122.94

122.90

114.79

115.38

116.39

119.11

120.85

G0.9

G0.8

MG

G0.5

MG

MG

MG

MG

MG

MG

G0.7

G1

MG

G0.6

G0.6

G1

MG

G0.8

G1.1

MG

MG

G1.1

2.4

x43m

viz

i

2.4

x43m

viz

i

Indicative junction

resurfacing in

contrasting materials

Large Refuse Vehicle (3 axle)

Tree root

protection

zone

Carriageway widening to

incorporate Pedestrian Refuge

Proposed Northern

Access

158

WESTWOOD HEATH ROAD

150

2b

140

611

COPT OAK CL

107

113

2a

162

154

142

93

103

2

148

450

2c

2d

448

458

LB

611a

2e

119

138

456

454

2.4

x47m

viz

i

2.4

x47m

viz

i

St

St

St

St

St

St

St

St

St

St

St St

St

Sv

Sv

Sv

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

LpLp

Lp

Lp

Sp

TCL:

TCL:

TCL:

TCL:

Post

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:R:

R:

R:

R:

R:

R:

R:

R:

Mkr

Mkr

Tp

Tp

TpTp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

TpTp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

THL

THL

Cbox

Wo

Fh

Bus

Bus

LBox

LBox

IB

IB

IB

Bin

Bin

Stay

ICU

ICU

ICU

Bush

GH2124.608

GH2A121.998

GH2B117.464

120.95

123.30

126.85123.94

121.96

143.24

143.24

132.92

118.61

127.31

131.24

128.31

131.39

132.27

131.05

130.99

128.38

128.72

130.29

126.09

129.48

128.40

126.01

131.06

131.67

133.77

134.06

130.72

128.43

128.45

133.88

134.03

131.62

131.52

129.72

127.62

130.59

133.11133.11

130.74

131.02

133.05

127.87

130.36

128.38

130.69

127.76

124.63

124.01

127.71

126.85

124.31

125.04

125.33

129.26

G2.2

MG

G2.2

G3

G1

G0.8

G0.9

G0.8

MG

G0.5

MG

MG

MG

MG

SLOW

MG

SLOW

Large Re

fuse Veh

icle (3 a

xle)

2.4

x47m

viz

i

Large Refuse Vehicle (3 axle)

Existing bus shelter

to be relocated into

verge

Tree root

protection zone

Tree rootprotectionzone

Carriageway widening to

incorporate Refuge

Proposed Southern

Access

Footway connection

to existing bus stop

9.86

1.795 3.9 1.4

Large Refuse Vehicle (3 axle)Overall Length 9.860mOverall Width 2.450mOverall Body Height 3.814mMin Body Ground Clearance 0.366mTrack Width 2.450mLock-to-lock time 4.00sCurb to Curb Turning Radius 9.500m

1:500 @ A1

Proposed Access

Points - Tracking

2082-04

JL June 16

Cromwell Lane, Coventry

Heyford Developments Ltd and

UK Land Development Ltd

Rev A.

-

Tel: 0121 475 0234 Fax 0121 475 2027

[email protected]

www.philjonesassociates.co.uk

Seven House, High Street,

Longbridge, Birmingham, B31 2UQ

File

: T

:\P

roje

cts

Curr

ent\#2000\0

2082 C

rom

well

Lane\G

raphic

s\2

082 a

ccess 7

.dw

g

Key

Highway Boundary

Site Boundary

Visibility Splays

Tactile Paving

Notes.

Dimensions shown are in metres unless stated otherwise.

Road markings & traffic signs are to be in accordance with 'The Traffic Signs

Regulations and General Directions 2002'

Tactile paving is to be in accordance with 'Guidance on the use of tactile

paving surfaces 2007'

The design shown is aligned with Ordnance Survey ProMap data and not

topographical survey data. Dimensions will require verification on site.

Visibility Splays shown are taken from 'MFS'

2.4x43m vizi

Drawing Status:

These drawings have been produced with reference to the CDM Regulations 2015; Regulation 9.

These Drawings are for planning approvals and are not to be used for construction purposes. It is the responsibility of the

contractor and client to identify risks associated with the construction stage and to design appropriate measures to mitigate.

The risks identified on the PJA Scheme Design Risk Assessment are based on the information available at the time of the

design (drawing date) Where shown on PJA Design Drawings, the position of services is based on information provided by

other parties at the time of the design and is for guidance only. It is the responsibility of the Client and Contractor to verify

the exact position of any services before commencing works on site.

Client Duties:

The client is directed to Regulation 4 of the CDM 2015 Regulations: Client duties in relation to managing projects

Key

Vehicle track

Body over

hang (green)

Wheel track

(red)

Page 4: head to end of Alan Higgs Way added - Coventry · Tel: 0121 475 0234 Fax 0121 475 2027 admin@philjonesassociates.co.uk Seven House, High Street, Longbridge, Birmingham, B31 2UQ File:

23

BO

UR

CH

IER

CLO

SE

40

10

1 to 30

2418

107.3m

PENRUDDOCK DRIVE

Tile Hill Station

Woodgate House

30

Pond

ETL

Post

1

1 to

25

32

1

2

14

11

10

9

El Sub Sta

7

Warehouse

4

1 to 18

Ryton House

Hidcote House

2

17

ALAN HIGGS WAY

19

ALA

N H

IGG

S W

AY

Re

ReRe

Re

St

St

St

St

St

St

St

StSt

St

StStSt

St

StSt

StSt

St

St

St

St

St

St

St

St

StSt

Sv

Sv

Sv

Sv

Sv

Sv

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Sp

Sp

Sp

Sp

Sp

Sp

TCL:

TCL:

TCL:

TCL:

TCL:

TCL:

TCL:

Vp

E:

E:

E:

E:

E:

E:E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E: E:

E:

E:

E:

E:

E:

R:

R:

R:

R:

R:R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

Tp

Tp

Tp

So

Fh

Fh

Fh

Fh

Bus

Bus

Stay

GrL

GrL

GrL

GrL

GrLGH6108.462

GH7109.643

GH2E111.745

GH2F109.670

GH2G108.365

GH2H107.647

115.74

118.56

117.76

115.11

115.16

114.93

117.99

117.30

114.71

117.83117.82

114.69114.99

117.99

114.93

118.73

115.75

111.45

111.26

111.01

117.75

117.98

117.78

117.70

117.71

117.33

114.61

116.99

114.72

114.72

114.72

114.77

114.86

114.97

115.21

118.22

121.76

119.68

116.92

115.71

118.02

118.89

116.57

115.40

114.28

121.12

118.18

121.72

112.07

109.52

114.61

117.05

117.05

114.62

114.67

116.88

116.84

114.59

114.58116.85

114.58116.83

117.53

114.70

114.81117.40

114.94

117.73

117.11

114.81

115.71

118.02

121.76

120.62

120.32

116.80

116.85

118.26

MG

MG

G0.6MG

MG

G2

G2

G1.5

MG

G1.3

G2.5

G2.7

MG

G1

MG

MG

MG

MG

MG

G0.8

MGMG

SLOW

SLOW

SLOW

Proposed collapsible

bollards to allow access

for maintenance vehicles

Existing road to be

downgraded to

footway / cycleway

Indicative route of

footway / cycleway

1:200 @ A1

Alan Higgs Way

Ped / Cycle Access

2082-02

JL May 16

Cromwell Lane, Coventry

Rev A.

-

Tel: 0121 475 0234 Fax 0121 475 2027

[email protected]

www.philjonesassociates.co.uk

Seven House, High Street,

Longbridge, Birmingham, B31 2UQ

File

: T

:\P

roje

cts

Cu

rre

nt\

#2

00

0\0

20

82

Cro

mw

ell

La

ne

\Gra

ph

ics\2

08

2 a

cce

ss 7

.dw

g

Key

Highway Boundary

Site Boundary

Visibility Splays

Tactile Paving

Notes.

Dimensions shown are in metres unless stated otherwise.

Road markings & traffic signs are to be in accordance with 'The Traffic Signs

Regulations and General Directions 2002'

Tactile paving is to be in accordance with 'Guidance on the use of tactile

paving surfaces 2007'

The design shown is aligned with Ordnance Survey ProMap data and not

topographical survey data. Dimensions will require verification on site.

Visibility Splays shown are taken from 'MFS'

Surfacing and lighting matters reserved.

2.4x43m vizi

Drawing Status:

These drawings have been produced with reference to the CDM Regulations 2015; Regulation 9.

These Drawings are for planning approvals and are not to be used for construction purposes. It is the responsibility of the

contractor and client to identify risks associated with the construction stage and to design appropriate measures to mitigate.

The risks identified on the PJA Scheme Design Risk Assessment are based on the information available at the time of the

design (drawing date) Where shown on PJA Design Drawings, the position of services is based on information provided by

other parties at the time of the design and is for guidance only. It is the responsibility of the Client and Contractor to verify

the exact position of any services before commencing works on site.

Client Duties:

The client is directed to Regulation 4 of the CDM 2015 Regulations: Client duties in relation to managing projects

Heyford Developments Ltd and

UK Land Development Ltd

Page 5: head to end of Alan Higgs Way added - Coventry · Tel: 0121 475 0234 Fax 0121 475 2027 admin@philjonesassociates.co.uk Seven House, High Street, Longbridge, Birmingham, B31 2UQ File:

912

75

94

CLOSE

COLEBY

CR

OM

WE

LL L

AN

E

67

14

83

80

93

87

46

103

97

79

16

86

4

12

Surgery

50

89

63

CHARTER AVENUE

2.4

x43m

viz

i

2.4

x43m

viz

i

St St

St

St

St

St

St

St

Sv

Sv

SvSv

Sv

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Sp

Sp

Sp

TCL:

TCL:

TCL:

Post

Post

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

Fh

Fh

Gas

Bus

Bolla

rds

Bo

ICU

ICU

GH2B117.464

GH2C116.179

GH2D114.316

117.62

117.70

120.47

123.05

120.58

123.29

120.62

119.19

123.64

124.49

121.75

120.10

119.21

118.38

122.88

118.17

119.63

122.94

122.90

114.79

115.38

116.39

119.11

120.85

G0.9

G0.8

MG

G0.5

MG

MG

MG

MG

MG

MG

G0.7

G1

MG

G0.6

G0.6

G1

MG

G0.8

G1.1

MG

MG

G1.1

2.4

x43m

viz

i

2.4

x43m

viz

i

Indicative junction

resurfacing in

contrasting materials

Tree root

protection

zone

Carriageway widening to

incorporate Pedestrian Refuge

Proposed Northern

Access

158

WESTWOOD HEATH ROAD

150

2b

140

611

COPT OAK CL

107

113

2a

162

154

142

93

103

2

148

450

2c

2d

448

458

LB

611a

2e

119

138

456

454

2.4

x47m

viz

i

2.4

x47m

viz

i

St

St

St

St

St

St

St

St

St

St

St St

St

Sv

Sv

Sv

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

Lp

LpLp

Lp

Lp

Sp

TCL:

TCL:

TCL:

TCL:

Post

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

E:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:

R:R:

R:

R:

R:

R:

R:

R:

R:

Mkr

Mkr

Tp

Tp

TpTp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

TpTp

Tp

Tp

Tp

Tp

Tp

Tp

Tp

THL

THL

Cbox

Wo

Fh

Bus

Bus

LBox

LBox

IB

IB

IB

Bin

Bin

Stay

ICU

ICU

ICU

Bush

GH2124.608

GH2A121.998

GH2B117.464

120.95

123.30

126.85123.94

121.96

143.24

143.24

132.92

118.61

127.31

131.24

128.31

131.39

132.27

131.05

130.99

128.38

128.72

130.29

126.09

129.48

128.40

126.01

131.06

131.67

133.77

134.06

130.72

128.43

128.45

133.88

134.03

131.62

131.52

129.72

127.62

130.59

133.11133.11

130.74

131.02

133.05

127.87

130.36

128.38

130.69

127.76

124.63

124.01

127.71

126.85

124.31

125.04

125.33

129.26

G2.2

MG

G2.2

G3

G1

G0.8

G0.9

G0.8

MG

G0.5

MG

MG

MG

MG

SLOW

MG

SLOW

2.4

x47m

viz

i

Existing bus shelter

to be relocated into

verge

Tree root

protection zone

Tree rootprotectionzone

Carriageway widening to

incorporate Refuge

Proposed Southern

Access

Footway connection

to existing bus stop

1:500 @ A1

Proposed Access

Points

2082-01

JL June 16

Cromwell Lane, Coventry

Heyford Developments Ltd and

UK Land Development Ltd

Rev A.

-

Tel: 0121 475 0234 Fax 0121 475 2027

[email protected]

www.philjonesassociates.co.uk

Seven House, High Street,

Longbridge, Birmingham, B31 2UQ

File

: T

:\P

roje

cts

Curr

ent\#2000\0

2082 C

rom

well

Lane\G

raphic

s\2

082 a

ccess 7

.dw

g

Key

Highway Boundary

Site Boundary

Visibility Splays

Tactile Paving

Notes.

Dimensions shown are in metres unless stated otherwise.

Road markings & traffic signs are to be in accordance with 'The Traffic Signs

Regulations and General Directions 2002'

Tactile paving is to be in accordance with 'Guidance on the use of tactile

paving surfaces 2007'

The design shown is aligned with Ordnance Survey ProMap data and not

topographical survey data. Dimensions will require verification on site.

Visibility Splays shown are taken from 'MFS'

2.4x43m vizi

Drawing Status:

These drawings have been produced with reference to the CDM Regulations 2015; Regulation 9.

These Drawings are for planning approvals and are not to be used for construction purposes. It is the responsibility of the

contractor and client to identify risks associated with the construction stage and to design appropriate measures to mitigate.

The risks identified on the PJA Scheme Design Risk Assessment are based on the information available at the time of the

design (drawing date) Where shown on PJA Design Drawings, the position of services is based on information provided by

other parties at the time of the design and is for guidance only. It is the responsibility of the Client and Contractor to verify

the exact position of any services before commencing works on site.

Client Duties:

The client is directed to Regulation 4 of the CDM 2015 Regulations: Client duties in relation to managing projects