hdd hdd hdd hdd - fujitsu.com · 5 main unit product available hdd interface height revolution...
TRANSCRIPT
Oct.2001
MS610
N4000
H200
N800
ES320
N400
B225
TS225 TS125
B125
System Configuration Guide V.10
System Configuration Guide (V.10) (October / 2001)
NotesAppliance Server WebAccelerator
General Purpose ServerIA64 Rack Optimized Server PRIMERGY N4000
IA32 Rack Optimized Server PRIMERGY N800PRIMERGY N400PRIMERGY TS225/125
IA32 Value Pedestal Server PRIMERGY MS610PRIMERGY H200PRIMERGY ES320PRIMERGY B225PRIMERGY B125
ClusteringExternal DevicesRackmountHardware List
Index
The numbers on the left hand side of each page correspond to the various options available with PRIMERGYs as follows
1 CPU slot
2 RAM module slot
3 3.5 inch HDD Bay
4 5 inch Bay
5 RS-232C
6 PCI slot
7 ISA slot
8 Redundant PSU
9 Others
Key to
Or And
586263
42475256
1724
2937
28
9
12
1
�INDEX
Hardw
areList
NO
TE
SA
pplianceS
erverN
4000N
800N
400TS225/125
MS
610H
200E
S320
B225
B125
Clustering
External
Devices
Rackmount
Disk array configuration
� Physical pack � � � A collection of physical HDDs comprising a RAID. � Logical drive � � � The logical drive (e.g. D: ) as seen by the Operating System.� Partition � � � One of the logical access units into which a logical drive is divided.
Physical pack
Logical drive A
Logical drive B * Drives can be divided into partitions.
Logical drive C
<Restrictions>
(1) Each physical pack must contain the same type(size) of HDDs. (2) Maximum logical drive size is 2TB. GP5-143/1441/145/146/148 / PG-143B/144B: In case of comprising the physical pack beyond 2TB, please be sure to divide into some logical drives in order that the capacity of one logical drive is less than 2TB. GP5-150/1501/151 / PG-141B/142B/142C: One physical pack is comprised by one logical drive (A physical pack is the same capacity as a logical drive). (3) The number of HDDs comprising a physical pack is as shown below.
RAID Level Description HDDs Capacity of logical drives
RAID 0 The data is broken down into blocks, 2~8(16) The capacity of logical drive is sameeach on a separate disk drive as the capacity of connected HDD.
RAID 1 Duplicates the disk and writes 2 The capacity of the logical drive isthe same data onto two disks. half the capacity of connected HDD.
RAID 5 The data is broken down into blocks 3~8(16) The capacity of each logical drive isand each blocks is written together the number of connected HDDs - 1). with parity bits on a separate disk drive.
RAID 6(0+1) Duplicates the disk and broken down 3~8(16) The capacity of each logical driveinto blocks, each on a is the half the capacity of connectedseparate disk. (RAID0+1) HDD. (GP5-143/1441/145/146/148,
PG-141B/142B/142C/143B/144B)
*1 GP5-148/150/1501/151/PG-141B/142B/PG-142C : Up to 16 HDD can be connected
*2 GP5-150/1501/151/PG-141B/142B/PG-142C: Number of HDD is even number from 4 to 16
(4) The same RAID level must be used when dividing a physical pack into a number of logical drives.(5) A physical pack must contain only HDDs which are connected by the same RAID card.(6) A RAID card can support more than one physical pack. ( even if different RAID levels)(7) In case that the same capacity HDDs are connected to the same RAID Card, these HDDS must also have the same rpm speed.
RAID
This must be 9GBwith 7200rpm HDD!9GB
7200rpm
9GB7200rpm
9GB10000rpm
Partition 1Partition 2
HDD HDD HDD HDD
*1
*1
*1 *2
2
�NOTESN
OT
ES
3
Hard disk cabinet / RAID card / SCSI card
� Hard Disk Cabinet (GP5MS623A)/Storage System (GP5UR1DC5)/PRIMERGY S30 (PGUR1DC6/PGUDC106)
The operating System must be installed on an internal hard disk. (Except N800)
Architecture difference between Storage System and S30
Hard Disk Cabinet/Storage System
Both single backplane (1ch/8bays) and split backplane (1ch/4bays x2) are available
PRIMERGY S30
The backplane of S30 is split
<Restriction>
Up to thirteen HDDs can be mounted in S30
when connecting with PG-142B/PG-142C
� RAID Controller Card GP5-143/1441/145/146/148 / PG-143B/144B
1.Up to two disk subsystems can be connected to one RAID card. <Exceptions> - Up to three can be connected with one GP5-1441/PG-143B - Up to four can be connected with one PG-144B
2.Internal and external array devices cannot be connected to the same channel.3.GP5-143/1441/145/146 can only be used with GP5-143/1441/145/146, they cannot be mixed with GP5-148)4.One GP5-148 can be installed in a server. (This restriction will be eliminated later)5. GP5-143 is used only for internal HDD connection.6. One GP5-143 can be mounted in a server7. When installing Operating System in the HDD connected to PG-144B, up to 4GB memory can be mounted in a server.
GP5-150/1501/151 / PG-141B/142B/142C1. RAID0+1, Array expansion is not available2. GP5-150/1501, up to 4GB memory can be mounted in MS610 (This restriction will be eliminated later)3. GP5-151/PG-141B are used only for internal HDD connection.4. One GP5-151/PG-141B can be mounted in a server
Bay1 Bay2 Bay3 Bay4
Bay5 Bay6 Bay7 Bay8
<Connection illustration Split Backplane>
Bay1 Bay2 Bay3 Bay4 Bay5 Bay6
<Connection illustration>
Ultra2 Wide SCSI 0ch
Ultra2 Wide SCSI 1ch
Bay7
Bay8 Bay9 Bay10 Bay11 Bay12 Bay13 Bay14
Ultra160 0ch
Ultra160 1ch
Bay1 Bay2 Bay3 Bay4
Bay5 Bay6 Bay7 Bay8
<Connection illustration(Single Backplane)>
Ultra2 Wide SCSI 0ch
NO
TE
S�NOTES
Combination matrix of RAID CardGP5-143 GP5-1441 GP5-145 GP5-146 GP5-148 GP5-150 GP5-1501 GP5-151 PG-141B PG-142B PG-142C PG-143B PG-144B
GP5-143 x o o o x x x x x x x x xGP5-1441 o o o o x o o o x x x x xGP5-145 o o o o x o o o x x x x xGP5-146 o o o o x o o o x x x x xGP5-148 x x x x x x x x xGP5-150 x o o o o o o x x x x xGP5-1501 x o o o o o o x x x x xGP5-151 x o o o o o x x x x x xPG-141B x x x x x x x x x o o x xPG-142B x x x x x x x x o o o o oPG-142C x x x x x x x x o o o o oPG-143B x x x x x x x x x o o o oPG-144B x x x x x x x x x o o o o
*1 Mounting more than two GP5-148 is restricted (it will be eliminated later).*2 The combination of GP5-148 and GP5-150/1501/151 is available only in ES320.*3 GP5-143/151/PG-141B are only used for internal HDD connection (One card can be installed).
RAID Cabling Kit (PGBCBLS012)Cabling instruction when mounting RAID Controller on CTO.
Default With RAID Cabling Kit
Even if RAID Controller is mounted by CTO, With this instruction, SCSI Cable is connectedSCSI Cable is connected to Onboard SCSI to the mounted RAID Controller.Controller.
Applicable products : MS610/N400/H200/ES320/B225/B125*TS225: SCSI Cable will be automatically connected with RAID Card when SCSI Cable (GP5B845) is ordered
� SCSI Card (GP5-126 / GP5-127)1.Internal and external devices cannot be connected to the same SCSI card.2.Only one Hard disk cabinet can be connected. (Daisy chain connection is not available)
� SCSI Controller (PG-123/126/128)No restrictions
Number of connectable Hard Disk Cabinets
Product TS125 TS225 B125 B225 ES320 H200 N400 MS610 N800 N4000Hard Disk Node
Hard Disk Cabinet GP5MS623A - - - - 4 - - 4 - -
Storage System GP5UR1DC5 - 1 - - 4 - - 4 - -
PRIMERGY S30 PGUR1DC6 - 1 - 1 2 6 3 9 -
PRIMERGY S30 PGUDC106 - - - 1 2 - 3 - -
*1 *2 *2 *2
*2
*2
*2 *3
*3
Motherboard
RAID Controller
Motherboard
RAID Controller
*3
10
10
4
�NOTESN
OT
ES
5
Main unit Product Available HDD Interface Height Revolution RemarksProduct ID
TS125 Hard disk drive-40GB GP5-HD4E51 ATA100 *1 1" 5400rpm IDE HDDHard disk drive-40GB GP5-HD4E71 ATA100 *1 1" 7200rpm IDE HDDHard disk drive-9GB GP5-HD9G4 Ultra160 1" 10000rpmHard disk drive-18GB GP5-HD8G2 Ultra160 1" 10000rpmHard disk drive-36GB GP5-HD6G1 Ultra160 1" 10000rpm
TS225 Hard disk drive-9GB GP5-HDH9D Ultra160 1" 10000rpmHard disk drive-18GB GP5-HDH8A Ultra160 1" 10000rpmHard disk drive-18GB GP5-HDH8B Ultra160 1" 15000rpmHard disk drive-36GB GP5-HDH63 Ultra160 1" 10000rpm
B125 Hard disk drive-40GB PG-HD4E5C ATA100 *2 1" 5400rpm IDE HDDHard disk drive-40GB PG-HD4E7C ATA100 *2 1" 7200rpm IDE HDDHard disk drive-9GB PG-HD9G1C Ultra160 1" 10000rpmHard disk drive-18GB PG-HD8G1C Ultra160 1" 10000rpmHard disk drive-36GB PG-HD6G1C Ultra160 1" 10000rpm
B225 Hard disk drive-9GB PG-HD9G1C Ultra160 1" 10000rpmHard disk drive-18GB PG-HD8G1C Ultra160 1" 10000rpm Non Hot-plug HDDHard disk drive-36GB PG-HD6G1C Ultra160 1" 10000rpmHard disk drive-9GB PG-HDH91C Ultra160 1" 10000rpmHard disk drive-18GB PG-HDH81C Ultra160 1" 10000rpm Hot-plug HDDHard disk drive-36GB PG-HDH61C Ultra160 1" 10000rpm
ES320 Hard disk drive-9GB GP5-HDH9C Ultra160 1" 7200rpmHard disk drive-9GB GP5-HDH9D Ultra160 1" 10000rpmHard disk drive-18GB GP5-HDH89 Ultra160 1" 7200rpmHard disk drive-18GB GP5-HDH8A Ultra160 1" 10000rpmHard disk drive-18GB GP5-HDH8B Ultra160 1" 15000rpmHard disk drive-36GB GP5-HDH63 Ultra160 1" 10000rpm
H200 Hard disk drive-9GB PG-HDH97A Ultra160 1" 7200rpmHard disk drive-9GB PG-HDH91A Ultra160 1" 10000rpmHard disk drive-18GB PG-HDH87A Ultra160 1" 7200rpmHard disk drive-18GB PG-HDH81A Ultra160 1" 10000rpmHard disk drive-18GB PG-HDH85A Ultra160 1" 15000rpmHard disk drive-36GB PG-HDH61A Ultra160 1" 10000rpm
N400 Hard disk drive-9GB PG-HDH97B Ultra160 1" 7200rpmHard disk drive-9GB PG-HDH91B Ultra160 1" 10000rpmHard disk drive-18GB PG-HDH87B Ultra160 1" 7200rpmHard disk drive-18GB PG-HDH81B Ultra160 1" 10000rpmHard disk drive-18GB PG-HDH85B Ultra160 1" 15000rpmHard disk drive-36GB PG-HDH61B Ultra160 1" 10000rpm
MS610 Hard disk drive-9GB GP5-HDH9B Ultra160 1" 7200rpmHard disk drive-9GB GP5-HDH9A Ultra 160 1" 10000rpmHard disk drive-18GB GP5-HDH88 Ultra160 1" 7200rpmHard disk drive-18GB GP5-HDH87 Ultra 160 1" 10000rpmHard disk drive-18GB GP5-HDH8B Ultra 160 1" 15000rpmHard disk drive-36GB GP5-HDH63 Ultra 160 1" 10000rpm
N800 Hard disk drive-9GB PG-HDH91B Ultra 160 1" 10000rpmHard disk drive-18GB PG-HDH81B Ultra 160 1" 10000rpmHard disk drive-18GB PG-HDH85B Ultra 160 1" 15000rpmHard disk drive-36GB PG-HDH61B Ultra 160 1" 10000rpm
N4000 Hard disk drive-36GB PG-HDH61D Ultra 160 1" 10000rpm
*1 IDE HDD of TS125 works on PIO mode.*2 ATA100 HDD is limted to DMA66 transfer rate by the motherboard of B125
Mountable Hard Disk Drives for each model
NO
TE
S�NOTES
Configuration To Order (CTO) is available with PRIMERGY N800/MS610/N400/H200/ES320/B225/B125/TS225/TS125 (N/A on N4000).Products are delivered with options (HDD, Memory, Backup device, etc.) already mounted as per customer requirements.
1. How shipped
2. Applicable products for CTO
(1)Main unitN800 / MS610 /N400/ H200 / ES320 / B225 / B125 / TS225 / TS125Storage System (GP5UR1DC5) / Hard Disk Cabinet (GP5MS623A) / Backup Cabinet (GP5UR1BC2) PRIMERGY S30 (PGUR1DC6/PGUDC106) / PRIMERGY S10 (PGUR1BC3)
(2) Option (GP5BXXX / PGBXXX)All options which name is with prefix "GP5B" or "PGB" are available for CTO.
� FUJITSU Rack Products
Products Product ID Remarks40U Rack GP5-R1RC640U Rack & Rack Coupling Kit GP5-R1RC736U Rack PG-R3RC1 36U+HUB Space36U Rack & Rack Coupling Kit PG-R3CN1 36U+HUB Space24U Rack GP5-R2RC324U Rack & Rack Coupling Kit GP5-R2RC424U Rack PG-R4RC1 24U+HUB Space24U Rack & Rack Coupling Kit PG-R4CN1 24U+HUB Space
The figure below indicates the height of each nodeProducts Height (Unit)PRIMERGY WebAccelerator SJ10R/MJ10R 1UPRIMERGY TS125 1UPRIMERGY TS225 1UPRIMERGY B225 5UPRIMERGY ES320 4UPRIMERGY H200 7UPRIMERGY N400 4UPRIMERGY MS610 7UPRIMERGY N800 7UPRIMERGY N4000 7UBackup Cabinet (GP5UR1BC2) 3UStorage System (GP5UR1DC5) 4UPRIMERGY S10 (PGUR1BC3) 3UPRIMERGY S30 (PGUR1DC6) 3UKeyboard/Monitor Shelf Kit (GP5-R1TB5/6) 9U, 1U *1Component Shelf (GP5-R1TB4/7) 1U *2Keyboard/Monitor Enhanced Switch (GP5-SB101) - *3Keyboard/Monitor Enhanced Switch (GP5-SB102) 1UPower Distribution Unit (GP5UPDU1) - *3Cable Holder (GP5-R1CH1) - *3Flat Display (GP5UR1DP11) 2U*1 GP5-R1TB6 occupies 9U for Monitor, and 1U for Keyboard.*2 The height of Unit depends on height of the loaded equipment. *3 When GP5-SB101 is installed with Monitor, it is vertically mounted beside the monitor. When installed with Flat Display, it is horizontally put on the Component Shelf (GP5-R1TB7), or vertically mounted in the vacant Rack space.
Configuration To Order
[CTO option]
(1) CPU+Chassis+Memory +
Shipment[Main unit]
(2) Mount option in free slots
(3) Standard Memory / Drive Cage conversion
Rackmounting
6
�NOTESN
OT
ES
7
� Notes
(1) PRIMERGY Rackmount Node should be mounted in FUJITSU 19"Rack.(2) When more than two Racks are connected, please be sure to use Rack & Rack Coupling Kit (GP5-R1RC7, GP5-R2RC4, PG-R3CN1, PG-R4CN1) for secondary Rack. Maximum number of connectable Rack is two (40U/36U) and three (24U). (3) 1U vacant Rack space is required for cabling, when N800 or MS610 is mounted in the lowest Rack space of Rack (4) When Monitor/ Keyboard are installed in Rack, Keyboard/Monitor Shelf Kit (GP5-R1TB6) is required. Mountable Monitor is 15" Monitor, and Keyboard is Enhanced Keyboard (GP5-R1KB1).(5) When mounting each node as below, each Rackmounting Kit is required for mounting.
Nodes Mounted in …Storage System (GP5UR1DC5) 40U Rack: GP5-R1RC6/7 Rackmounting Kit
36U Rack: PG-R3RC1/2 GP5-R1RK524U Rack: GP5-R2RC3/4, PG-R4RC1/2
Backup Cabinet (GP5UR1BC1) 40U Rack: GP5-R1RC6/7 Rackmounting Kit36U Rack: PG-R3RC1/2 GP5-R1RK824U Rack: GP5-R2RC3/4, PG-R4RC1/2
Server monitoring software is bundled with all PRIMERGYs. The feature of each software is indicated below.
Items Servervisor Intel LANDesk Server Manager V6.0 ServerView
Product V1.1 TS125, TS225, ES320, MS610 H200, N400, N800
TS125, TS225, ES320, MS610 B125, B225
Main function Server status monitoring *1 Server status monitoring *1 Server status monitoring *1
Error notification Error message Error notification
Remote control ASR&R*3, Inventory information*4 display
WindowsNT performance monitoring WindowsNT/2000 performance monitoring
(e.g. CPU/Memory utilization) (e.g. CPU/PCI-bus utilization)
Alert function Internet mail transmission Internet mail transmission Internet mail transmission
SNMP Trap transmission SNMP Trap transmission SNMP Trap transmission
Message box Message box Message box
(On the monitored server) *2 (On the monitored server) *2 (On the monitored server) *2
Activation by program Activation by program
Broadcast to connected clients Broadcast to connected clients
SMM support No Yes No
Required memory capacity 6~10MB 32~64MB 16~32MB
Advantage Servervisor provides the minimum functions LDSM is suitable for systems employing ServerView has two management mode.
required for server management to reduce remote central monitoring or It is possible to select the suitable mode
the amount of resources used, SMM based monitoring to provide for system.
making it convenient for a small-scale a more powerful server management function. BASIC: Management for local server
system without a dedicated manager. - Powerful functions FULL: Management for big-scale system
- Simplified operation, light-weight by remote console monitoring.
- Easy to use
*1 Remote monitoring is provided by System Walker plus LiveHelp. Remote control and WindowsNT performance
monitor are provided by System Walker (LiveHelp is not required for LDSM).
*2 If the message box is to be displayed for server error detection, the message box must be logged on to the server.
Errors that occur while the message box is not logged on can be reported using Internet mail and SNMP Trap.
The event log also can be used to check whether such errors have occurred.
*3 ASR&R: AutoServer Reconfiguration and Reset (= ASR)
*4 Inventory information: Information viewer for each component (NOT supported by ServerView BASIC mode)
* No Server Management Tool is bundled in N4000
Server Management Tools Functional Comparison
NO
TE
S�NOTES
Specification
Type Rackmount
Product ID GP5T1TBB71 GP5T1TBB72
CPU Frequency Pentium® lll 800EBMHz
Number of CPUs 1
Memory 256KB 512KB
Internal BaysCD-ROM 24X (IDE)
Cache size 15GB 50GB
Network LAN(10/100 base TX) x 2
Dimension (mm) 461(W)x578(D)x42(H) Rackmount1U
Weight 11kg (max.)
Power consumption 150W (max.)
Typical Features of Internet Caching
1. Forward ProxyParticularly useful in Intranets or with xSPs who provide services to many customers. Here frequently accessed web pages are stored on a local caching appliance. This significantly reduces the number of times the origin server is accessed across the Intranet/Internet. The result is customers/clients get faster response; there is less overall network traffic and the result is Bandwidth savingsdue to less costly infrastructure upgrades.
(1)The client web browser requests web pages from its forward proxy server(2)The forward proxy service obtains the IP address from DNS server(3)The service obtains objects from web server(4)The service forwards copies of the retrieved objects to the client(5)The forward copy service handles subsequent requests for the web page objects without needing to access the DNS server or the web server.
2. Reverse ProxyThe WebAccelerator reduces response time and frees up Web server bandwidth.This allows the server to handle requests for less frequently requested, uncached data much more quickly.It also helps protect servers from access storms.WebAccelerator can also accelerate Web servers at remote locations that don't offer broadband connections. The WebAcceleratorcan be located close to the Internet backbone, ensuring high speed delivery to Web browsers of all cached objects.
(1) Request from browser.(2)DNS server returns the target IP address of the web server(3)WebAccelerator relays Internet access and monitors whether the web pages are cached or not(4)If the contents are not cached, WebAccelerator obtains the web contents from web server(5) Where the contents are cached, WebAccelerator returns copies of the objects to the browser
or the web server.
WebAccelerator
PRIMERGYWebAccelerator
Browser
Web Server
DNS Server
PRIMERGYWebAccelerator DNS Server
Web ServerRouter
8
�ApplianceServer
App
lianc
eS
erve
r
Specification of PRIMERGY N4000
Type Rackmount
Product ID PGTN46AT1R PGTN46ATRA
CPU Processor Itanium™
Frequency 800MHz
Cache (L1:16KB/Data:16KB, L2: 96KB, L3: 4MB)
Number of CPUs 1 (up to 4)
Memory Standard 1GB (256MB x 4)
Maximum 64GB (1GB x 64) *with Extension Board
VRAM 8MB VGA chip: ATI RAGE XL(PCI)
Internal Bays5-inch One (Occupied by DVD-ROM)
CD-ROM/DVD-ROM 8/24X DVD-ROM (ATAPI)
HDD bay 1inch x2/Hotplug
Standard HDD 36.4GB x1
Available HDD 36.4GB(10000rpm)
Maximum 72.8GB (36.4GB x 2)
Expansion slot PCI64bit 66MHz x8, PCI64bit 33MHz x 2
SCSI Interface Internal: Ultra160 x 1, External: Ultra160 x 1
Network LAN(10/100 base TX) x 1 (Onboard)
Dimension (mm) 445(W)x712(D)x312(H) Rackmount7U
Weight 68kg (max.)
Power consumption 1800W (max.)
Power supply Three standard units (Forth unit is for redundant)
Fan units Six units (Redundant, Hotplug, and Proactive)
Operating System Windows®Advanced Server Limited Edition is bundled*1 None
*1 With Windows Advanced Server Limited Edition, you cannot use the parallel port to connect a printer.
Mounting Additional Memory
� Standard Memory Board Configuraion (Less than 32slots are used) - Mount the same capacity DIMM's in banks of four - Mount the DIMM's in ascending order of their capacity. Use DIMM slots in order starting at Slot1 to Slot4 => Slot5 to Slot8 => Slot9 to Slot12 => Slot13 to Slot16… Slot29 to Slot32.
� Standard and Additional Memory Board Configuraion (More than 32slots are used) - Mount the same capacity DIMM's in banks of four - Mount the DIMM's in ascending order of their capacity. Use DIMM slots in order starting at Standard Memory Board Slot1 to Slot4 => Additional Memory Board Slot1 to Slot4 => Standard Memory Board Slot5 to Slot8 => Additional Memory Board Slot5 to Slot8 …. - In case of different size of memories are installed, mount the bank of four DIMM's in ascending order of their capacity. - For memory performance improvement by interleave between Memory Boards, mounting same size in the same slot is recommended to install in both Standard Memory Board and Additional Memory Board.
PRIMERGY N4000
StandardMemory Board
256MB256MB
#1
#2
#9
#10#17#18
#25
#26
#32
#31
#24
#23#16
#15#8
#7
256MB
256MB
#5
#6
#13
#14#21#22
#29
#30
#28
#27
#20
#19#12
#11#4
#3
256MB256MB
1GB
1GB
#1
#2
#9
#10#17
#18#25
#26
#32
#31
#24
#23#16
#15
#8#7
1GB1GB
256MB
256MB
#5
#6
#13
#14#21
#22#29
#30
#28
#27
#20
#19#12
#11
#4#3
256MB256MB
1GB
1GB
#1
#2
#9
#10#17#18
#25
#26
#32
#31
#24
#23#16
#15#8
#7
1GB1GB
256MB
256MB
#5
#6
#13
#14#21#22
#29
#30
#28
#27
#20
#19#12
#11#4
#3
StandardMemory Board
AdditionalMemory Board
9
�N4000N
4000
� PCI resource areaA part of address area as below is assigned for PCI resource, cannot be used.Operating System do not use 62GB~64GB memory space even if the system installed 64GB memory .Operating System Mounted Memory Size The area for PCI resourceWindows®Advanced Server ~62GB No area for PCI resourceLimited Edition 62GB ~64GB 62GB ~64GB
Mounting devices
- In N4000, there are two internal HDD bays (2bays/1ch)- PRIMERGY S10 (Backup Cabinet) is available if DLT8000/DDS4 are installed- External HDD connection is not available
� Configuration Chart
N4000
� Connection Matrix
PRIMERGY N4000Connection of internal HDD and internal backup devices
Internal HDD Backup device
Connection Pattern
Configuration SCSI Host Cable Internal HDD PRIMERGY S10 is connected
Interface
SCSI Onboard SCSI Controller Cable(X1) Up to two HDDs can be Onboard SCSI Controller (WideB)
Configuration Ultra160 Ch0 => Internal HDD x 2 (Standard installed PRIMERGY S10 (PGUR1BC3)
equipment) 1) 36GB, 10,000rpm SCSI Cable (Standard equipment)
Mountable I/O options
N4000Maximum
number
Cards Product ID Bus of cards Total REMARKS
mounted
EthernetController PG-185 PCI64 3 4
(100Base-TX)
EthernetController PG-188 PCI64 2
(1000Base-SX) 2
EthernetController PG-189 PCI64 2
(1000Base-T)
Ultra160 Ch0
Ultra160 Ch1
OnboardSCSI
For Internal HDD
For PRIMERGY S10
Onboard SCSI Controller(Ultra160 x 2)
PRIMERGY S10(PGUR1BC3)
Ch0
Ch1
10
�N4000N
4000
Connection Table
PGTN46AT1R Rackmount Type 1 x Itanium™ 800MHz, Memory:1GB(ECC), HDD: 36.4GB x 1, NOS: Windows®Advanced Server Limietd Edition is bundled
PGTN46ATRA Rackmount Type 1 x Itanium™ 800MHz, Memory:1GB(ECC), HDD: 36.4GB x 1, NOS: No Operating System is bundled
Rackmount Type
<Items>
CPU Field Upgrade : Go to A
Memory addition : Go to B
Internal Hard Disk Drive connection Go to C
Backup devices Go to D
Others (NIC etc.) Go to E
* CTO is not available in N4000
Max : 4CPUs Itanium 800MHz, 4MB SLC
A: 1 PG-FG10T
Standard : 1CPU
Standard memory : 1GB (256MB-DIMMx4) Max. memory: 64GB Main Memory 4GB (1GB SDRAM DIMMx4)
B: 2 PG-RM4F
Main Memory 1GB (256MB SDRAM DIMMx4)
2 Additional Memory Board PG-RM1F
PG-RB104
Standard HDD : 36.4GB x 1 Max : 2 Hard Disk - 36GB (Ultra160 10,000rpm)
C: 3 (Hot Plug)
PG-HDH61D
Up to four Tape units can be mounted
Onboard SCSI Controller Tape Drive DLT8000
D: 4 PRIMERGY S10 PG-DL401/PGBDL401
PGUR1BC3 Two 5" bays are occupied
SCSI Cable
Standard equipment
Tape Drive DAT DDS4
PG-DT401/PGBDT401
Gigabit Ethernet Controller (1000Base-T)
E: 6 PG-189
Gigabit Ethernet Controller (1000Base-SX)
6 PG-188
Fast Ethernet Controller (100Base-TX)
6 PG-185
Power Supply Module
8 (Redundant Power Supply Unit)
PG-PU104
Memory
Others
CPU
Internal Hard Disk
Backup Devices
11
�N4000N
4000
Specification of PRIMERGY N800
Type Rackmount
Product ID PGTN8BH2R3 PGTN8BG2R3
CPU Processor Pentium® lll Xeon™
Frequency 700MHz
Secondary cache 2MB 1MB
Number of CPUs 2 (up to 8)
Memory Standard 1GB (256MB x 4)
Maximum 32GB (1GB x 32)
VRAM 8MB VGA chip: ATI RAGE XL(PCI)
Internal Bays5-inch Two (one occupied by DVD-ROM)
CD-ROM/DVD-ROM 8/24X DVD-ROM (ATAPI)
HDD bay 1inch x4/Hotplug
Available HDD 9.1GB(10000rpm)/18.2GB(10000/15000rpm)/36.4GB(10000rpm)
Maximum 145.6GB (36.4GB x 4)
Expansion slot PCI64bit 100MHz(PCI-X) x4, PCI64bit 33MHz x 6
SCSI Interface Internal: Ultra160 x 1, External: Ultra160 x 1
RAID controller 2 x Ultra160 (occupying one 64bit/33MHz PCI slot)
Network LAN(10/100 base TX) x 1 (occupying one 64bit/33MHz PCI slot)
Dimension (mm) 445(W)x712(D)x312(H) Rackmount7U
Weight 60kg (max.)
Power consumption 710W (max.)
Power supply Three standard units (the third unit is for redundant)
Mounting Additional Memory
A memory board with 16slots is standard equipment and up to 16GB memory can be mounted. When you add more than 16GB, an additional Memory Board (PG-RB103/PGBRB103) is required.When using two memory boards in N800, the same memory size must be mounted on each board.
� PCI resource areaA part of address area as below is assigned for PCI resource, cannot be used.Operating System Mounted Memory Size The area for PCI resource
~3.8GB No area for PCI resourceWindows®2000 Server/Advanced Server 3.8GB ~4.0GB 3.8GB ~4.0GBWindowsNT®4.0 Server E.E. 4.0GB ~32.0GB 3.8GB ~4.0GB[Maximum Memory Size:32GB]
� Installation of WindowsNT® ServerWhen installation, WindowsNT cannot be installed if more than 2GB memory is mounted in the server.(Please add DIMMs after the installation is completed)
Mounting devices
- In N800, there are four internal HDD bays (2bays/1ch x 2)- N800 has one internal 5" bay in chassis for DDS4 (In case of SCSI connection, the DDS4 is available for
daisy-chain connection with HDD)- PRIMERGY S10 (Backup Cabinet) is available if " more then two backup devices" or "backup devices except for DDS4"
are installed.
PRIMERGY N800
Standard Memory Board
256MB
256MB
256MB
256MB
512MB
512MB
512MB
512MB#1 #2 #3 #4
#5 #6 #7 #8 #9 #10 #11 #12
#13 #14 #15 #16
256MB
256MB
256MB
256MB
512MB
512MB
512MB
512MB#1 #2 #3 #4
#5 #6 #7 #8 #9 #10 #11 #12
#13 #14 #15 #16
Additional Memory Board (PG-RB103)
12
�N800N
800
� Configuration Chart
N800
or
� Connection Matrix
PRIMERGY N800Connection of internal HDD and internal backup devices
Internal HDD Backup device
Connection Pattern
Configuration SCSI Host Cable Internal HDD Internal DDS4 PRIMERGY S10 is connected
Interface
Up to four HDDs can be
SCSI Onboard SCSI Cable(X2) installed Onboard SCSI SCSI Controller (PG-126)
Configuration Ultra160 Controller (Standard 1) 9GB, 10,000rpm (Ultra160 Ach) PRIMERGY S10 (PGUR1BC3)
WideA => Internal HDD x 2 equipment) 2) 18GB, 10,000rpm SCSI Cable (PG-CBLS001/002/003)
WideB => Internal HDD x 2 3) 18GB, 15,000rpm
4) 36GB, 10,000rpm
Up to four HDDs can be Onboard SCSI (Ultra160 Bch)
Array Standard Cable(X2) installed Onboard SCSI PRIMERGY S10 (PGUR1BC3)
Configuration Ultra160 RAID Controller (Ch0/1) (Standard 1) 9GB, 10,000rpm (Ultra160 Ach) SCSI Cable (PG-CBLS007/008/009)
(Standard) 0ch => Internal HDD x 2 equipment) 2) 18GB, 10,000rpm or1ch => Internal HDD x 2 3) 18GB, 15,000rpm SCSI Controller (PG-126)
4) 36GB, 10,000rpm PRIMERGY S10 (PGUR1BC3)
SCSI Cable (PG-CBLS001/002/003)
- In case of SCSI configuration (Up to four HDDs can be mounted), internal DDS4 can be connected to ChA of Onboard SCSI by daisy chain.
- when connecting RAID Controller with PRIMERGY S30, or SCSI Controller with Internal HDD, both SCSI Channel of Onboard SCSI Controller must be connected
to Internal HDD.
Channel 0
Ultra160 A
Ultra160 B
OnboardSCSI
For Internal HDD/PRIMERGYS30
Channel 1
For Internal Backup device/Internal HDD
StandardRAID Controller
For PRIMERGY S10/Internal HDD
Onboard SCSI Controller(Ultra160 x 2)
RAID Controller (Standard)(Ultra160 x 2)
DDS4(Option)
PRIMERGY S10(PGUR1BC3)
ChA
Ch0 Ch1
ChB
SCSI Controller(PG-126)
PRIMERGY S10(PGUR1BC3)
For Internal HDD/PRIMERGYS30
13
�N800N
800
Mountable I/O options
N800Maximum
number
Cards Product ID Bus of cards Total REMARKS
mounted
SCSI Controller PG-123 PCI64 4 4 10 For external SCSI Device
(Ultra Wide Diff)
SCSI Controller PG-126 PCI64 2
(Ultra2 Wide LVD)
Fibre Channel Controller PG-FC102 PCI64 4
RAID Controller Standard PCI64 1 5 Mounted in PCI slot1
(Ultra160 LVD) Equipment
RAID Controller PG-142B/C PCI64 4 Note:(Ultra160 LVD) PG-144B/PG-189 cannot be installed in RAID Controller PG-144B PCI64 2 PGTN8BH2R2/PGTN8BG2R2(Ultra160 LVD)
EthernetController Standard PCI64 1 4 Mounted in PCI slot3
(100Base-TX) Equipment
EthernetController PG-185 PCI64 3
(100Base-TX)
EthernetController PG-188 PCI64 2
(1000Base-SX)
EthernetController PG-189 PCI64 3
(1000Base-T)
Remote Service Board PGURSB101PCI64 1 For Remote Management
Connection Table
PGTN8BH2R3 Rackmount Type 2 x Pentium® lll Xeon™ 700MHz(2MB), Memory:1GB(ECC), HDD:Option
PGTN8BG2R3 Rackmount Type 2 x Pentium® lll Xeon™ 700MHz(1MB), Memory:1GB(ECC), HDD:Option
Rackmount Type
<Items>
CPU Field Upgrade : Go to A
Memory addition : Go to B
Standard Memory Conversion : Go to C
Internal Hard Disk Drive connection Go to D
External Hard Disk Drive connection Go to E
Backup devices Go to F
Others (NIC etc.) Go to G
Max : 8CPUs CPU Field Upgrade Kit - 74 (Pentium III Xeon 700MHz (2MB) x1
A: 1 GP5-FG20HT/GP5BFG20HT
Standard : 2CPUs
CPU Field Upgrade Kit - 73 (Pentium III Xeon700MHz (1MB) x1
GP5-FG20GT/GP5BFG20GT
Standard memory : 1GB (256MB-DIMMx4) Max. memory: 32GB Additional Memory - 512MB (256MB-DIMMx2)
B: 2 GP5-RM51J/GP5BRM51J
Additional Memory - 1GB (512MB-DIMMx2)
2 Additional Memory Board GP5-RM1J/GP5BRM1J
PG-RB103/PGBRB103
Additional Memory - 2GB (1GB-DIMMx2)
GP5-RM2J/GP5BRM2J
Memory
CPU
14
�N800N
800
C: 2 Standard Memory Conversion Kit-2GB (512MB SDRAM-DIMMx4
PGBRU2C
Standard Memory Conversion Kit-4GB (1GB SDRAM-DIMMx4)
PGBRU4C
Max : 4 Hard Disk - 9GB (Ultra160 10,000rpm)
D: 6 (Hot Plug)
Standard RAID Controller PG-HDH91B/PGBHDH91B
(Ultra160/2ch/64MB cache)
Hard Disk - 18GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH81B/PGBHDH81B
Hard Disk - 18GB (Ultra160 15,000rpm)
(Hot Plug)
PG-HDH85B/PGBHDH85B
Hard Disk - 36GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH61B/PGBHDH61B
Max:14
* Up to thirteen HDD can be mounted in S30 when connecting with PG142B/C
Hard Disk - 9GB (Ultra160 7,200rpm)
E: 6 (Hot Plug)
RAID Controller PG-HDH97B/PGBHDH97B
Ultra160/2ch SCSI Cable(2m) PRIMERGY S30
64MB Cache PG-CBLS004 PGUR1DC6 Hard Disk - 9GB (Ultra160 10,000rpm)
PG-142B/PGB142B (Hot Plug)
PG-HDH91B/PGBHDH91B
RAID Controller SCSI Cable(5m) Hard Disk - 18GB (Ultra160 7,200rpm)
Ultra160/2ch PG-CBLS005 (Hot Plug)
64MB Cache/BBU PG-HDH87B/PGBHDH87B
PG-142C/PGB142C
Hard Disk - 18GB (Ultra160 10,000rpm)
SCSI Cable(10m) (Hot Plug)
RAID Controller PG-CBLS006 PG-HDH81B/PGBHDH81B
Ultra160/2ch * Cannot be used with PG-144B
128MB Cache/BBU Hard Disk - 18GB (Ultra160 15,000rpm)
PG-144B/PGB144B (Hot Plug)
PG-HDH85B/PGBHDH85B
Hard Disk - 36GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH61B/PGBHDH61B
Power Supply Module
Max:1 PGUPU103/PGBUPU103
Internal Hard Disk
Standard RAID Controller Conversion Kit(Standard RAID to PG-142C)(Ultra160/2ch/64MB Cache/BBU)PGB1U42C1
Standard Memory Conversion
External Hard Disk
15
�N800N
800
Up to four Tape units can be mounted
Onboard SCSI Controller Tape Drive DLT8000
F: PRIMERGY S10 PG-DL401/PGBDL401
PGUR1BC3 Two 5" bays are occupied
SCSI Cable(1.8m)
PG-CBLS007 Tape Drive DLT7000
PG-DL351/PGBDL351
Two 5" bays are occupied
SCSI Cable(5m) Tape Drive DLT4000
PG-CBLS008 PG-DL201/PGBDL201
Two 5" bays are occupied
Tape Drive LTO
SCSI Cable(10m) PG-LT101/PGBLT101
PG-CBLS009
6
SCSI Controller U2W Tape Drive SLR100
PG-126/PGB126 SCSI Cable(1.5m) PG-SL101/PGBSL101
PG-CBLS001
Tape Drive SLR60
PG-SL601/PGBSL601
SCSI Cable(5m)
PG-CBLS002
Tape Drive SLR50
PG-ML301/PGBML301
SCSI Cable(10m)
PG-CBLS003 Tape Drive DAT DDS4
PG-DT401/PGBDT401
Tape Drive DAT DDS3
PG-DT301/PGBDT301
Tape Drive DAT DDS4 Autoloader
PG-DTA102/PGBDTA102
Two 5" bays are occupied
Onboard SCSI Controller Tape Drive DAT DDS4 Tape Drive DAT DDS3 Autoloader
PG-DT401/PGBDT401 PG-DTA101/PGBDTA101
Only one DDS4 can be mounted in 5"bay Two 5" bays are occupied
Gigabit Ethernet Controller (1000Base-SX)
G: 6 PG-188/PGB188
Gigabit Ethernet Controller (1000Base-T)
6 PG-189/PGB189
Fast Ethernet Controller (100Base-TX)
6 PG-185/PGB185
Fibre Channel Controller
6 PG-FC102
Remote Service Board Kit B Remote Service Board
6 PG-RSBOP2 PGURSB101
Others
Backup Devices
16
�N800N
800
Type Rackmount
Product ID PGTN4AH1R2 PGTN4AG1R2
CPU Processor Pentium® lll Xeon™
Frequency 700MHz
Secondary cache 2MB 1MB
Number of CPUs 1 (up to 4)
Memory Standard 512MB (128MB x 4)
Maximum 16GB (1GB x 16)
Internal Bays 5-inch Option (one available)
CD-ROM 24X (ATAPI)
HDD bay 1inch x4/Hotplug
Available HDD 9.1GB(10000/7200rpm)/18.2GB(15000/10000/7200rpm)/36.4GB(10000rpm)
Maximum 145.6GB (36.4GB x 4)
Expansion slot PCI64bit 66MHz x2, PCI64bit 33MHz x 4, PCI32bit/33MHz x2
SCSI Interface Ultra160 x 2
RAID controller Option
Network LAN(10/100 base TX) x 1 (Onboard)
Dimension (mm) 483(W)x718(D)x177(H) Rackmount4U
Weight 43kg (max.)
Power consumption 700W (max.)
Power supply Two standard units (the third unit is for redundant)
Mounting Additional Memory
Mount the same capacity DIMM's in units of four.(Mounting of DIMM's with different capacities or a set of less than four DIMM's is not allowed) Mount the DIMM's in ascending order of their capacity. Use DIMM slots in the order from bank 1 (1.1 to 1.4) to bank 4 (4.1 to 4.4)
� PCI resource areaA part of address area as below is assigned for PCI resource, cannot be used.Operating System Mounted Memory Size The area for PCI resourceWindowsNT®4.0 ~3.25GB No area for PCI resourceWindows®2000 Server 3.25GB ~4.0GB 3.25GB ~4.0GB*[Maximum Memory Size:4.0GB]
~3.25GB No area for PCI resourceWindows®2000 Advanced Server 3.25GB ~4.0GB 3.25GB ~4.0GB*[Maximum Memory Size:8.0GB] 4.0GB ~8.0GB 3.25GB ~4.0GB*
* Address area of 0.1~0.75GB is assigned for PCI (Slightly fluctuate depend on the configuration)
� Installation of WindowsNT® ServerWindowsNT cannot be installed if more than 2GB memory is mounted in the server.(Please add DIMMs after the installation is completed)
PRIMERGY N400
Mother Board
4.43.42.41.44.33.32.31.3
1.12.13.14.11.22.23.24.2
Specification
17
�N400N
400
Mounting internal device
� Backplane Pattern
- Standard Drive CageSCSI Channel � � � 1ch
Number of mountable HDD � � � 1inch height Hard Disk Drive x 4 (4HDDs per 1ch)
<Connection illustration>
- Upgrade Kit 2Channels Internal (PGBBU102)SCSI Channel � � � 2ch
Number of mountable HDD � � � 1inch height Hard Disk Drive x 4 (2HDDs per 1ch x 2)
<Connection illustration>
- Removable Media Bay Cage (PGBBU103)SCSI Channel � � � 2ch
Number of mountable HDD � � � 1inch height Hard Disk Drive x 2 (2HDDs per 1ch)Number of mountable Backup Device � � � 1inch height Backup Device x1
<Connection illustration>
or orDDS4 DDS3 SLR50/60/100
� 5-inch bay installation
Bay1: Used for CD-ROM (IDE) (Support as standard)Bay2: SCSI ID = 4~6 (Setting on the device side), SCSI ID = 4 (CTO)
A DAT(DDS4, DDS3), SLR Unit(50/60/100) can be installed in this bay
Note: One backup device can be installed in Removable media bay with option (PGBBU103)
Bay1 Bay2
Bay4 Bay3
Bay1 Bay2
Bay1 Bay2
Bay3 Bay4
18
�N400N
400
� External Onboard SCSI Interface (PGBCBL011)
Onboard SCSI Channels are also used for connecting PRIMERGY S10 with option as"External Onboard SCSI Interface (PGBCBLS011)".
<Connection illustration>
PRIMERGY S10
* External SCSI Cable is sold separately
Connection of internal HDD and internal backup devicesThe following figure indicates the correct adapters (Onboard SCSI channel, SCSI Controller, etc.) to use to mount devices in N400.
Internal HDD Backup devices
Connection Pattern One device is connected Two devices are connected
Configuration Drive Cage SCSI Host Cable Internal HDD Narrow (*1) x1 Narrow (*1) x2 Narrow(*1) + Wide(*2)
Interface or Wide(*2) x1 or Wide(*2) x2 connection
connection connection
PRIMERGY S10 PRIMERGY S10
Standard Ultra 160 Onboard SCSI Cable(X1) (Backup Cabinet) (Backup Cabinet)
(4Bays/1ch) (Ch A) (Standard N/A External Onboard External Onboard
equipment) SCSI Interface SCSI Interface
(PGBCBLS011) (PGBCBLS011)
SCSI PRIMERGY S10 PRIMERGY S10
Configuration Drive Cage Ultra 160 Onboard SCSI Cable(X2) (Backup Cabinet) (Backup Cabinet)
Conversion (Ch A/Ch B) (Standard N/A SCSI Controller SCSI Controller
(4Bays/2ch) equipment)*3 (PG-126) (PG-126)
1) 9GB, 7,200rpm PRIMERGY S10 PRIMERGY S10
Drive Cage Ultra 160 Onboard SCSI Cable(X2) 2) 9GB, 10,000rpm Onboard SCSI (Backup Cabinet) (Backup Cabinet)
Conversion (Ch A) (Standard 3) 18GB, 7,200rpm (Ch B) SCSI Controller SCSI Controller
(2Bays/1ch equipment)*3 4) 18GB, 10,000rpm (PG-126) (PG-126)
+ Backup Device) 5) 18GB, 15,000rpm
6) 36GB, 10,000rpm
Standard RAID Controller Cable(X1)
(4Bays/1ch) Ultra160 PG-142B/142C/ (Standard N/A
144B (Ch0) equipment)
Array
Configuration PRIMERGY S10 PRIMERGY S10
Drive Cage RAID Controller Cable(X2) (Backup Cabinet) (Backup Cabinet)
Conversion Ultra160 PG-142B/142C/ (Standard N/A External Onboard External Onboard
(4Bays/2ch) 144B (Ch0/1) equipment)*3 SCSI Interface SCSI Interface
(PGBCBLS011) (PGBCBLS011)
Drive Cage RAID Controller Cable(X2) Onboard SCSI
Conversion Ultra160 PG-142B/142C/ (Standard (Ch B)
(2Bays/1ch 144B (Ch0) equipment)*3
+ Backup Device)
*1 Narrow connect devices: PG-DT301/PG-DTA101/PG-DL201(Wide-Narrow conversion cable is standard equipment with all Narrow connected devices)
*2 Wide connect devices: PG-DT401/PG-DTA102/PG-DL351/PG-ML301(SCSI Cable is standard equipment with all Wide connect devices)
*3 One SCSI Cable is standard equipment of each Drive Cage option (PGBBU102/PGBBU103)
Ultra160 Ach
Ultra160 Bch
OnboardSCSI
For HDD/Backup Cabinet
For HDD/Internal Backup Device/Backup Cabinet
Bay1 Bay2
Mother Board of N400
19
�N400N
400
Mountable I/O options
N400Maximum
number
Cards Product ID Bus of cards Total REMARKS
mounted
SCSI Controller PG-126 PCI32 2 For internal Backup device
(Ultra2 Wide LVD) 8
FibreChannel Controller PG-FC102 PCI64 4
RAID Controller PG-142B PCI64 2 2 4
(Ultra160)
RAID Controller PG-142C PCI64 2
(Ultra160)
RAID Controller PG-143B PCI64 4
(Ultra2 Wide)
RAID Controller PG-144B PCI64 3
(Ultra160)
Ethernet Controller PG-183 PCI64 2 2 4 Giga LAN
(1000Base-SX)
Ethernet Controller PG-188 PCI64 2 Giga LAN
(1000Base-SX)
Ethernet Controller PG-189 PCI64 2 Giga LAN
(1000Base-T)
Ethernet Controller PG-185 PCI32 3 Note:(100Base-TX) PG-143B/PG-144B/PG-188/PG-189 cannot be installed in Remote Service Board PGURSB101 PCI32 1 For Remote Management PGTN4AG1R/PGTN4AH1R
Connection Table
PGTN4AH1R2 Rackmount Type 1 x Pentium® lll Xeon™ 700MHz(2MB)
PGTN4AG1R2 Rackmount Type 1 x Pentium® lll Xeon™ 700MHz(1MB)
<Items>
CPU Field Upgrade : Go to A
Memory addition : Go to B
Rackmount Type Standard Memory Conversion Go to C
Internal HDD/backup device
1. SCSI Configuration (HDD) Go to D
2. Array Configuration (HDD) Go to E
3. Backup device (Internal) Go to F
Connect with Storage Subsystem Go to G
Backup Devices (Backup Cabinet) Go to H
Others Go to I
Max : 4CPUs
A: 1 Pentiumlll Xeon 700MHz/100MHz, 2MB SLC (CPU Field Upgrade Kit)
Standard : 1CPU PG-FG10H/PGBFG10H
Pentiumlll Xeon 700MHz/100MHz, 1MB SLC (CPU Field Upgrade Kit)
PG-FG10G/PGBFG10G
CPU
20
�N400N
400
Max. memory: 16GB (1GB DIMM x16)
B: 2 Main Memory 4GB (1GB SDRAM DIMMx4)
Standard memory : 512MB (128MB-DIMMx4) PG-RM4B/PGBRM4B
Main Memory 2GB (512MB SDRAM DIMMx4)
PG-RM2B/PGBRM2B
Main Memory 1GB (256MB SDRAM DIMMx4)
PG-RM1B/PGBRM1B
Main Memory 512MB (128MB SDRAM DIMMx4)
PG-RM51B/PGBRM51B
Main Memory 256MB (64MB SDRAM DIMMx4)
PG-RM25B/PGBRM25B
Standard Memory Conversion Kit-4GB (1GB SDRAM-DIMMx4)
C: 2 PGBRU4B
Standard Memory Conversion Kit-2GB (512MB SDRAM-DIMMx4)
PGBRU2B
Standard Memory Conversion Kit-1GB (256MB SDRAM-DIMMx4)
PGBRU1B
3 Standard SCSI Backplane (1inch HDD x 4/1ch)
Split SCSI Backplane Option (1inch HDD x 4/2ch)
Upgrade Kit 2Channels Internal : PGBBU102
Up to four HDDs can be mounted in the main unit Hard Disk 9GB (Ultra160 7,200rpm)
D: 3 (Hot Plug)
Onboard SCSI Controller PG-HDH97B/PGBHDH97B
Hard Disk 9GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH91B/PGBHDH91B
Hard Disk 18GB (Ultra160 7,200rpm)
(Hot Plug)
PG-HDH87B/PGBHDH87B
Hard Disk 18GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH81B/PGBHDH81B
E: 6 Hard Disk 18GB (Ultra160 15,000rpm)
RAID Controller U160 2Channels (Hot Plug)
(64MB Cache/Ultra160 SCSI) PG-HDH85B/PGBHDH85B
PG-142B/PGB142B
Hard Disk 36GB (Ultra160 10,000rpm)
(Hot Plug)
RAID Controller U160 2Channels PG-HDH61B/PGBHDH61B
(64MB Cache/Ultra160 SCSI/Battery Backup)
PG-142C/PGB142C
Go to the same HDD as SCSI configuration
RAID Controller U2W 3Channels
(64MB Cache/Ultra2 Wide SCSI/Battery Backup)
PG-143B/PGB143B
RAID Controller U160 4Channels
(128MB Cache/Ultra160 SCSI/Battery Backup)
PG-144B/PGB144B
Memory
SCSI Configuration
Array Configuration
Standard Memory conversion
Internal HDD / Internal backup device
21
�N400N
400
F: 6 Removable Media Bay Cage : PGBBU103 Tape Drive DAT DDS4
PG-DT401/PGBDT401
Tape Drive DAT DDS3
PG-DT301/PGBDT301
Tape Drive SLR100
PG-SL101/PGBSL101
Tape Drive SLR60
PG-SL601/PGBSL601
Tape Drive SLR50
PG-ML301/PGBML301
G: 6
RAID Controller U160 2Channels Max:14HDDs
(64MB Cache/Ultra160 SCSI) SCSI Cable (2m) *Up to thirteen HDDs can be mounted in S30 when connecting
PG-142B/PGB142B PG-CBLS004 with PG-142B/PG-142C
Hard Disk 9GB (Ultra160 7,200rpm)
RAID Controller U160 2Channels SCSI Cable(5m) (Hot Plug)
(64MB Cache/Ultra160 SCSI/ PG-CBLS005 PG-HDH97B/PGBHDH97B
Battery Backup)
PG-142C/PGB142C Hard Disk 9GB (Ultra160 10,000rpm)
(Hot Plug)
SCSI Cable(10m) PG-HDH91B/PGBHDH91B
RAID Controller U2W 3Channels PG-CBLS006
(64MB Cache/Ultra2 Wide SCSI/ * Cannot be used with PG-144B Hard Disk 18GB (Ultra160 72,00rpm)
Battery Backup) (Hot Plug)
PG-143B/PGB143B PG-HDH87B/PGBHDH87B
Hard Disk 18GB (Ultra160 10,000rpm)
RAID Controller U160 4Channels (Hot Plug)
(128MB Cache/Ultra160 SCSI/ PG-HDH81B/PGBHDH81B
Battery Backup)
PG-144B/PGB144B Hard Disk 18GB (Ultra160 15,000rpm)
(Hot Plug)
PG-HDH85B/PGBHDH85B
Hard Disk 36GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH61B/PGBHDH61B
Power Supply Module
Max: One additional PSU (Redundant Power Supply Unit)
PGUPU103/PGBUPU103
Connect with Storage Subsystem
PRIMERGY S30PGUR1DC6
Backup Device (Internal)
22
�N400N
400
PRIMERGY S10
(Backup Cabinet)
PGUR1BC3
H: 6 Up to four Tape units can be mounted
SCSI Controller U2W
PG-126/PGB126 SCSI Cable(1.5m) Tape Drive DLT8000
PG-CBLS001 PG-DL401/PGBDL401
Two 5" bays are occupied
Tape Drive DLT7000
SCSI Cable(5m) PG-DL351/PGBDL351
PG-CBLS002 Two 5" bays are occupied
Tape Drive DLT4000
PG-DL201/PGBDL201
SCSI Cable(10m) Two 5" bays are occupied
PG-CBLS003
Tape Drive LTO
PG-LT101/PGBLT101
9 External onboard SCSI interface
PGBCBLS011 (As of Beg Feb)
SCSI Cable(1.8m) Tape Drive SLR100
PG-CBLS007 PG-SL101/PGBSL101
Tape Drive SLR60
SCSI Cable(5m) PG-SL601/PGBSL601
PG-CBLS008
Tape Drive SLR50
PG-ML301/PGBML301
SCSI Cable(10m)
PG-CBLS009
Tape Drive DAT DDS4
PG-DT401/PGBDT401
Tape Drive DAT DDS3
PG-DT301/PGBDT301
Tape Drive DAT DDS4 Autoloader
PG-DTA102/PGBDTA102
Two 5" bays are occupied
Tape Drive DAT DDS3 Autoloader
PG-DTA101/PGBDTA101
Gigabit Ethernet Controller (1000Base-SX) Two 5" bays are occupied
I: 6 PG-183/PGB183
Gigabit Ethernet Controller (1000Base-SX)
6 PG-188/PGB188
Gigabit Ethernet Controller (1000Base-T)
6 PG-189/PGB189
Fast Ethernet Controller (100Base-TX)
6 PG-185/PGB185
Fibre Channel Controller
6 PG-FC102
Remote Service Board Kit A Remote Service Board
6 PG-RSBOP1 PGURSB101
Power Supply Module
8 (Redundant Power Supply Unit)
PG-PU102/PGBPU102
Backup Devices (Backup Cabinet)
Others
23
�N400N
400
Specification
Product TS225 TS125
Type Rackmount
Product ID GP5T2TCLR GP5T2TCER GP5T1TCLR GP5T1TCER
CPU Pentium®lll
Frequency 1BGHz 933MHz 1BGHz 933MHz
Secondary cache 256KB
Number of CPUs 1 (up to 2) 1
Memory Standard 128MB (128MB x 1)
Maximum 4GB (1GB x 4)
VRAM 4MB VGA chip: ATI RAGE XL(PCI)
Internal Bays 5-inch One (For CD-ROM)
CD-ROM (Option) 24X Slim (ATAPI)
HDD bay 1inch x 3 (Hotplug) 1inch x 2 (Non Hotplug)
Standard HDD - 1x40.9GB/5400rpm(IDE)
Available HDD (Ultra160) 9.1GB(10000rpm)/18.2GB(10000/15000rpm)/36.4GB(10000rpm) 9.1GB(10000rpm)/18.2GB(10000rpm)/36.4GB(10000rpm)
(EIDE) N/A 40.9GB (7200/5400rpm: IDE)
Maximum 109.2GB (36.4GB x 3) 81.8GB (40.9GB x 2)
Expansion slot PCI64bit 66MHz x1
SCSI Interface Ultra160 x1 (Itl.), Ultra Wide (Ext..)
RAID controller Option N/A
Network LAN(10/100 base TX) x 2 (onboard)
Dimension (mm) 440(W)x595(D)x43.5(H) Rackmount 1U
Weight Max. 12kg
Power consumption Maximum 190 W / 684 KJ/h
Power supply One standard units
The mother board has four slots for RAM modules (including base memory), install RAM modules in slot number order.
� PCI resource areaA part of address area as below is assigned for PCI resource, cannot be used.Operating System Mounted Memory Size The area for PCI resourceWindowsNT®4.0 ~3.5GB No area for PCI resourceWindows®2000 Server 3.5GB ~4.0GB 3.68GB ~4.0GB[Maximum Memory Size:4.0GB]
� Installation of WindowsNT® ServerWindowsNT cannot be installed if more than 2GB memory is mounted in the server.(Please add DIMMs after the installation is completed)
TS225 has three HDD bays and 36.4GB/18.2GB/9.1GB Ultra160 SCSI HDD (1"height) can be mounted.TS125 has two HDD bays and 36.4GB/18.2GB/9.1GB Ultra160 SCSI or 40.9GB IDE HDD (1"height) can be mounted.
PRIMERGY TS225/125Connection of internal HDD and internal backup devices
Mother Board of TS225 Mother Board of TS125
PRIMERGY TS225/125
Mounting additional memory
Mounting internal SCSI devices
For connection of external SCSI devices
SecondaryEIDE controller
Ultra WideSCSI controller
For Internal HDD
For connection of external SCSI devices
For CD-ROM (Opt)
PrimaryEIDE controller
ForCD-ROM (Opt.)
Ultra160SCSI controller
Ultra WideSCSI controller
For Internal HDD
EIDE controller
Ultra 160SCSI controller
For Internal HDD
24
�TS225/125TS
225/
125
Internal HDD External backup device
Connection Pattern One device is connected Two devices are connected
Connection Interface Host Internal HDD Narrow connect Wide connect Narrow device x 2 Narrow device x 2 Narrow device and
TS225 device *1 device *2 Wide device
SCSI Onboard SCSI
Configuration Ultra160 (Ultra160) 1)9GB, 10,000rpm Backup Cabinet (GP5UR1BC2)
2)18GB, 10,000rpm SCSI Cable (GP5S-832) is required
Array RAID Card 3)18GB, 15,000rpm Up to four backup devices can be mounted in GP5UR1BC2.
Configuration Ultra160 GP5-148/151 4)36GB, 10,000rpm
Connection Pattern One device is connected Two devices are connected
Connection Interface Host Internal HDD Narrow connect Wide connect Narrow device x 2 Narrow device x 2 Narrow device and
TS125 device *1 device *2 Wide device
SCSI Onboard SCSI 1)9GB, 10,000rpm
Configuration Ultra160 (Ultra160) 2)18GB, 10,000rpm Backup Cabinet (GP5UR1BC2)
3)36GB, 10,000rpm SCSI Cable (GP5S-832) is required
IDE Onboard EIDE 40.9GB, 5400rpm Up to four backup devices can be mounted in GP5UR1BC2.
Configuration PIO (Primary) (One HDD is Standard
equipment)
*1 Narrow connect devices: GP5UDL201/GP5UDT301/GP5USL501
*2 Wide connect devices: GP5-DT401/GP5-ML301(SCSI Cable is standard equipment with all Wide connect devices)
Mountable I/O options
TS225 TS125Maximum Maximum
number number
Cards Product ID Bus of cards Total REMARKS Cards Product ID Bus of cards Total REMARKS
mounted mounted
RAID card GP5-148 PCI64 1 Internal/External array Fibre Channel Card GP5-FC101 PCI64 1
(Ultra160) configuration Fibre Channel Card GP5-FC102 PCI64 1
RAID card GP5-150 PCI64 1 Internal/External array LAN card GP5-183 PCI64 1 Giga LAN
(Ultra160) configuration (1000Base-SX) 1
RAID card GP5-151 PCI64 1 Internal array configuration LAN card GP5-188 PCI64 1 Giga LAN
(Ultra160) (1000Base-SX)
Fibre Channel Card GP5-FC101 PCI64 1 LAN card GP5-189 PCI64 1 Giga LAN
Fibre Channel Card GP5-FC102 PCI64 1 (1000Base-T)
LAN card GP5-183 PCI64 1 Giga LAN LAN card GP5-185 PCI64 1
(1000Base-SX) 1 (100Base-TX)
LAN card GP5-188 PCI64 1 Giga LAN LAN card GP5-186 PCI64 1 Dual Port LAN
(1000Base-SX) (100Base-TX)
LAN card GP5-189 PCI64 1 Giga LAN LAN card GP5-187 PCI64 1 IPsec LAN
(1000Base-T) (100Base-TX)
LAN card GP5-185 PCI64 1
(100Base-TX)
LAN card GP5-186 PCI64 1 Dual Port LAN
(100Base-TX)
LAN card GP5-187 PCI64 1 IPsec LAN
(100Base-TX)
Connection Table
TS225
GP5T2TCLR: 1CPU(Pentium®lll1BGHz)/Rackmount Type
GP5T2TCER: 1CPU(Pentium®lll933MHz)/Rackmount Type
TS125
GP5T1TCLR: 1CPU(Pentium®lll1BGHz)/Rackmount Type
GP5T1TCER: 1CPU(Pentium®lll933MHz)/Rackmount Type
<Items>
CPU Field upgrade : Go to A
Memory addition : Go to B
Internal devices:
1. IDE HDD connection (TS125) Go to C
2. SCSI HDD connection (TS125) Go to D
3. SCSI HDD connection (TS225) Go to E
4. Array HDD connection (TS225) Go to F
5.Backup device: Go to G
Others (NIC, PSU, etc.) : Go to H
25
�TS225/125TS225/125
Max : 2CPUs
A: 1 CPU Field Upgrade Kit-84 (Pentium III-1BGHz (256KB) x1)
Standard:1CPU GP5-FG22L/GP5BFG22L
CPU Field Upgrade Kit-83 (Pentium III-933MHz (256KB) x1)
GP5-FG22E/GP5BFG22E
*CPU addition is only available on TS225
Max:4GB
B: 2 Additional Memory-128MB (128MB SDRAM-DIMMx1)
Standard:128MB (128MB-DIMMx1) GP5-RM12M/GP5BRM12M
Additional Memory-256MB (256MB SDRAM-DIMMx1)
GP5-RM25M/GP5BRM25M
Additional Memory-512MB (512MB SDRAM-DIMMx1)
GP5-RM51M/GP5BRM51M
Additional Memory-1GB (1GB SDRAM-DIMMx1)
GP5-RM1M/GP5BRM1M
Standard Memory conversion option
2 Standard Memory Conversion Kit-256MB
GP5BRU25H
Standard Memory Conversion Kit-512MB
GP5BRU51L
Standard Memory Conversion Kit-1GB
GP5BRU1GH
Number of mountable HDD: Two
Standard HDD Conversion
IDE Connection (EIDE 5,400rpm to EIDE 7,200rpm) Standard Hard Disk Drive Conversion Kit-40GB
C: 3 (EIDE40.9GB 7,200rpm) GP5BHU4G3
Onboard IDE Controller
Additional EIDE HDD Hard Disk Drive-40GB(EIDE, 5,400rpm)
(Standard equipment)
Hard Disk Drive-40GB(EIDE, 5,400rpm)
GP5-HD4E51/GP5BHD4E51
Hard Disk Drive-40GB(EIDE, 7,200rpm)
GP5-HD4E71/GP5BHD4E71
* IDE HDD is only available on TS125
Standard HDD Conversion
SCSI Connection: (Standard EIDE to Ultra160 SCSI) Standard Hard Disk Drive Conversion Kit-9GB
D: 3 (Ultra160, 10,000rpm, Non Hotplug) GP5BHU9GV
Onboard SCSI Controller
Standard Hard Disk Drive Conversion Kit-18GB
(Ultra160, 10,000rpm, Non Hotplug) GP5BHU8G11
Standard Hard Disk Drive Conversion Kit-36GB
(Ultra160, 10,000rpm, Non Hotplug) GP5BHU6GD
Additional SCSI HDD Hard Disk Drive - 9GB (Ultra 160, 10,000rpm)(Non Hot Plug)
GP5-HD9G4/GP5BHD9G4
Hard Disk Drive - 18GB (Ultra 160, 10,000rpm)(Non Hot Plug)
GP5-HD8G2/GP5BHD8G2
Hard Disk Drive - 36GB (Ultra 160, 10,000rpm)(Non Hot Plug)
GP5-HD6G1/GP5BHD6G1
Internal HDD / Internal backup device
CPU (Only TS225)
Memory
TS125
26
�TS225/125TS
225/
125
Number of mountable HDD: Three
SCSI Connection: Hard Disk Drive -9GB (Ultra160, 10,000rpm)(Hot Plug)
E: 3 GP5-HDH9D/GP5BHDH9D
Onboard SCSI Controller
Hard Disk Drive -18GB (Ultra160, 10,000rpm)(Hot Plug)
GP5-HDH8A/GP5BHDH8A
Hard Disk Drive -18GB (Ultra160, 15,000rpm)(Hot Plug)
GP5-HDH8B/GP5BHDH8B
Hard Disk Drive -36GB (Ultra160, 10,000rpm)(Hot Plug)
GP5-HDH63/GP5BHDH63
Array Connection:Hard Disk Drive -9GB (Ultra160, 10,000rpm)(Hot Plug)
F: 3 GP5-HDH9D/GP5BHDH9D
RAID Card
(64MB Cache/Ultra160) SCSI Cable
GP5-148/GP5B148 GP5-845/GP5B845 Hard Disk Drive -18GB (Ultra160, 10,000rpm)(Hot Plug)
GP5-HDH8A/GP5BHDH8A
RAID Card Hard Disk Drive -18GB (Ultra160, 15,000rpm)(Hot Plug)
(32MB Cache/Ultra160) SCSI Cable GP5-HDH8B/GP5BHDH8B
GP5-151/GP5B151 GP5-848/GP5B848
Hard Disk Drive -36GB (Ultra160, 10,000rpm)(Hot Plug)
GP5-HDH63/GP5BHDH63
CD-ROM unit (24X, Slim)
G: 4 GP5-CD313/GP5BCD313
9 Backup Cabinet DLT unit (DLT4000)
GP5UR1BC2 GP5UDL201/GP5BDL201
SCSI Cable Two 5" bays are occupied
GP5S-832
DAT unit (DDS3)
GP5UDT301/GP5BDT301
Up to four backup devices can be
mounted in GP5UR1BC2
Tape unit
GP5USL501/GP5BSL501
DLT unit (DLT7000)
GP5-DL351/GP5BDL351
Two 5" bays are occupied
DAT unit (DDS4)
GP5-DT401/GP5BDT401
Tape unit (MLR3)
GP5-ML301/GP5BML301
DAT autoloader (DDS4)
GP5-DTA102/GP5BDTA102
Two 5" bays are occupied
DAT autoloader (DDS3)
GP5-DTA101/GP5BDTA101
Two 5" bays are occupied
Redundant Power Supply Unit
GP5UPU151/GP5BUPU151
TS225
TS225/125
27
�TS225/125TS225/125
H: 6 LAN Card (1000Base-SX)
GP5-183/GP5B183
6 LAN Card (1000Base-SX)
GP5-188/GP5B188
6 LAN Card (1000Base-T)
GP5-189/GP5B189
6 LAN Card (100Base-TX)
GP5-185/GP5B185
6 LAN Card (100Base-TX Dual port)
GP5-186/GP5B186
6 LAN Card (100Base-TX IPsec)
GP5-187/GP5B187
Fibre Channel Card
6 GP5-FC101
Fibre Channel Card
6 GP5-FC102
Others
28
�TS225/125TS
225/
125
Specification
Type
Product ID GP5T6CH1A GP5T6CG1A
CPU Processor Pentium® lll Xeon™
Frequency 700MHz
Secondary cache 2MB 1MB
Number of CPUs 1 (up to 4)
Memory Standard 512MB (128MB x 4)
Maximum 16GB (1GB x 16)
VRAM 2MB VGA chip: ATI RAGEIIC(PCI)
Internal Bays 5-inch Three (one occupied by CD-ROM)
CD-ROM 40X (ATAPI)
HDD bay 1inch x 8 (up to 12bays with option)/Hotplug
Available HDD (Ultra160) 9.1GB(10000/7200rpm)/18.2GB(15000/10000/7200rpm)/36.4GB(10000rpm)
Maximum 291.2GB (436.8GB with 12bay cage option)
Expansion slot PCI64bit 66MHz x2, PCI64bit 33MHz x4, PCI32bit 33MHz x2
SCSI Interface Ultra160 x2, Wide or Narrow x1
RAID controller Option
Network LAN(10/100 base TX) x 1 (onboard)
Dimension (mm) Pedestal: 307(W)x700(D)x500(H)
Rackmount(7U): 482(W)x675(D)x307(H)
Weight 70kg (max.)
Power consumption 680W (max.)
Power supply Two standard units (up to three for redundant)/Hotplug
Mounting Additional Memory
Mount the same capacity DIMM's in units of four.(Mounting of DIMM's with different capacities or a set of less than four DIMM's is not allowed) Mount the DIMM's in ascending order of their capacity. Use DIMM slots in the order from bank A (A1 to A4) to bank D (D1 to D4)
Cooling Kit is required if more than three GP5-RM4N/GP5BRU4N/GP5BRU4GA are installed.
� PCI resource areaA part of address area as below is assigned for PCI resource, cannot be used.Operating System Mounted Memory Size The area for PCI resourceWindowsNT®4.0 ~3.5GB No area for PCI resourceWindows®2000 Server 3.5GB ~4.0GB 3.5GB ~4.0GB[Maximum Memory Size:4.0GB]
~3.5GB No area for PCI resourceWindows®2000 Advanced Server 3.5GB ~4.0GB 3.5GB ~4.0GB[Maximum Memory Size:8.0GB] 4.0GB ~8.0GB 3.5GB ~4.0GB
In case that more than two GP5-1441/150/1501 are mounted(Exception: When mounting RAID Cards in slot A1 and A2)Operating System Mounted Memory Size The area for PCI resourceWindowsNT®4.0 ~3.25GB No area for PCI resourceWindows®2000 Server 3.25GB ~4.0GB 3.25GB ~4.0GB[Maximum Memory Size:4.0GB]
~3.25GB No area for PCI resourceWindows®2000 Advanced Server 3.25GB ~4.0GB 3.25GB ~4.0GB[Maximum Memory Size:8.0GB] 4.0GB ~8.0GB 3.25GB ~4.0GB
PRIMERGY MS610
Memory BoardD1B1C1A1D3B3C3A3
D2B2C2A2D4B4C4A4
29
�MS610M
S610
� Installation of WindowsNT® ServerWindowsNT cannot be installed if more than 2GB memory is mounted in the server.(Please add DIMMs after the installation is completed)
� RestrictionIn case that GP5-150/1501 is mounted, maximum memory size is 4GB (This restriction will be eliminated later)
Mounting internal device
� Backplane Pattern
- Standard Drive CageSCSI Channel � � � 1ch
Number of mountable HDD � � � 1inch height Hard Disk Drive x 8 (8HDDs per 1ch)
<Connection illustration>
- Drive Cage Conversion Kit (GP5BBU1)SCSI Channel � � � 2ch
Number of mountable HDD � � � 1inch height Hard Disk Drive x 12 (6HDDs per 1ch x 2)
<Connection illustration>
� 5-inch bay installation
Bay1: Used for CD-ROM (IDE) (Support as standard)Bay2: SCSI ID = 4~6 (Setting on the device side), SCSI ID = 4 (CTO)
DAT(DDS4, DDS3), Tape Unit(MLR3, SLR5) can be installed in this bayBay3: SCSI ID = 4~6 (Setting on the device side), SCSI ID = 5 (CTO)
DAT(DDS4, DDS3), DAT Autoloader(DDS4, DDS3), Tape Unit(MLR3, SLR5), DLT Unit(DLT8000, DLT7000, DLT4000) can be installed in this bay
Note: A DAT Autoloader, DLT unit installed in 5-inch bay 3 will also occupy bay2 because of it's height.In some case, a separate SCSI Card is required when installing a Tape Unit (MLR3), DAT(DDS4), DAT Autoloader(DDS4) or DLT(DLT8000, DLT7000) in a 5-inch bay. See diagram below.
Bay1 Bay2 Bay3 Bay4
Bay8 Bay7 Bay6 Bay5
Bay1 Bay3 Bay5 Bay7
Bay2 Bay4 Bay6 Bay8
Bay9
Bay10
Bay11
Bay12
30
�MS610M
S61
0
Connection of internal HDD and internal backup devicesThe following figure indicates the correct adapters (Onboard SCSI channel, SCSI Card, etc.) to use to mount devices in MS610
Mother Board of MS610
The following figure indicates the right adapters (Onboard SCSI channel, SCSI Card, etc.) used to mount devices in MS610
Internal HDD Internal backup device
Connection Pattern One device is connected Two devices are connected
Configuration Drive Cage SCSI Host Cable Internal HDD Narrow Wide Narrow Wide Narrow device
Interface connect connect device x 2 device x 2 *3 and
device*1 device*2 Wide device *4
Standard Ultra 160 Onboard SCSI Cable(X1)
(8Bays) (Ultra160 A) (Standard
equipment)
SCSI When Drive Cable(X2) 1) 9GB, 7,200rpm Onboard Onboard Narrow-1,2 Wide-1 Onboard Narrow:
Configuration Cage Ultra 160 Onboard SCSI (Standard 2) 9GB, 10,000rpm SCSI SCSI(Wide ) Onboard SCSI(Wide) Onboard SCSI (Narrow)
Conversion (Ultra160 A/B) equipment) 3) 18GB, 7,200rpm (Narrow) SCSI (Narrow)
4) 18GB, 10,000rpm Daisy chain Wide-2 SCSI Card Wide:
(12Bays) 5) 18GB, 15,000rpm (GP5-127) SCSI Card (GP5-127)
RAID Card Cable(X1) 6) 36GB, 10,000rpm
Standard Ultra2 Wide GP5-1441/145/146(Ch0) (Standard
(8Bays) equipment)
Ultra160 148/150/1501 (Ch0)
Array When Drive RAID Card Cable(X2)
Configuration Cage Ultra2 Wide GP5-1441/145/146(Ch0/1) (Standard
Conversion equipment)
(12Bays) Ultra160 148/150/1501 (Ch0/1)
*1 Narrow connect devices: GP5UDL201/GP5UDT301/GP5USL501/GP5-DTA101
*2 Wide connect devices: GP5-DT401/GP5-DTA102/GP5-ML301/GP5-DL351/PG-DL401/PG-SL101/PG-SL601
SCSI Cable is standard equipment with all Wide connect devices (*In case of PG-DL401, SCSI CableGP5-849 is required)
*3 Daisy chain (Wide connect device - Wide connect device) is not available
*4 Daisy chain (Wide connect device - Narrow connect device) is not available
SCSI Cable is standard equipment (Narrow: Main unit/Wide: Backup device)
Mountable I/O options
MS610Maximum Restrictionsnumber - When GP5-186 is mounted, one other LAN Card
Cards Product ID Bus of cards Total REMARKS (GP5-183/185/187) can be mounted.mounted - Only one GP5-148 can be mounted in a server.
SCSI card GP5-123 PCI64 2 For external device (This restriction will be eliminated later)(Ultra Wide HVD) 4 8
Fibre Channel Card GP5-FC101 PCI64 2
Fibre Channel Card GP5-FC102 PCI64 2
SCSI card GP5-127 PCI64 3
(Ultra2 Wide LVD) 3
RAID card GP5-1441 PCI64 3
(Ultra2 Wide LVD)
RAID card GP5-145/146 PCI64 2
(Ultra2 Wide LVD)
RAID card GP5-148 PCI64 3
(Ultra160 )
RAID card GP5-150/1501 PCI64 3
(Ultra160 )
LAN card GP5-183 PCI64 1 3 Giga LAN
(1000Base-SX)
LAN card GP5-185 PCI32 3
(100Base-TX)
LAN card GP5-186 PCI32 1 Dual Port LAN
(100Base-TX)
LAN card GP5-187 PCI32 3 IPsec LAN
(100Base-TX)
Server Monitor Module GP5USM103 PCI32 1 1
Narrow
Ultra160 A
Ultra160 B
OnboardSCSI
For backup device (Wide)
For HDD
For HDD
Wide
For backup device (Narrow)
Select either of the SCSI channel
31
�MS610M
S610
Connection Table
GP5T6CH1A 1CPU(Pentium® lllXeon™ 700MHz/2MB)/Pedestal Type
GP5T6CG1A 1CPU(Pentium® lllXeon™ 700MHz/1MB)/Pedestal Type
<Items>
Form factor conversion (Pedestal to RackmounGo to A
CPU Field upgrade : Go to B
Pedestal Type Memory addition : Go to C
Standard memory conversion : Go to D
Internal devices (Standard Drive Cage)
1.SCSI HDD connection Go to E
2. Array HDD connection Go to F
3. Internal backup device Go to G
Internal devices (Drive Cage Conversion Kit)
1.SCSI HDD connection Go to H
2. Array HDD connection Go to I
Rackmount Type 3. Internal backup device Go to J
Others (NIC, PSU, etc.) : Go to K
Rack Conversion Kit
A: PGBR1CK4
B:
Max.4CPUs CPU Field Upgrade Kit -68 (Pentiumlll Xeon 700MHz (2MB) x1)
1 GP5-FG20H/GP5BFG20H
Standard : 1CPU
CPU Field Upgrade Kit - 67 (Pentiumlll Xeon 700MHz (1MB) x1)
GP5-FG20G/GP5BFG20G
Max.16GB (1GB DIMM x 16) Additional Memory-4GB (1GB SDRAM-DIMMx4)
C: 2 GP5-RM4N/GP5BRM4N
Standard : 512MB (128MB-DIMMx4)
High-Memory Cooling Kit (GP5-FN101/GP5BFN101)
(Required if more than three GP5-RM4N/GP5BRU4N/GP5BRU4GA
are installed)
Additional Memory-2GB(512MB SDRAM-DIMMx4)
GP5-RM2N/GP5BRM2N
Additional Memory-1GB(256MB SDRAM-DIMMx4)
GP5-RM1N/GP5BRM1N
Additional Memory-512MB(128MB SDRAM-DIMMx4)
GP5-RM51N/GP5BRM51N
D: 2 Standard Memory Conversion Kit-4GB (1GB SDRAM-DIMMx4)
GP5BRU4GB
Standard Memory Conversion Kit-2GB (512MB SDRAM-DIMMx4)
GP5BRU2GD
Standard Memory Conversion Kit-1GB (256MB SDRAM-DIMMx4)
GP5BRU1GJ
Memory
CPU
Standard Memory conversion
Form factor conversion(Pedestal to Rackmount)
32
�MS610M
S61
0
(Standard Drive Cage)
Standard Drive Cage
1inch height HDD x 8
Hard Disk Drive-9GB(Ultra160, 7,200rpm)
E: 3 1"height/Hotplug
Onboard SCSI Controller GP5-HDH9B/GP5BHDH9B
Hard Disk Drive-9GB(Ultra160,10,000rpm)
1"height/Hotplug
GP5-HDH9A/GP5BHDH9A
Hard Disk Drive-18GB(Ultra160, 7,200rpm)
1"height/Hotplug
GP5-HDH88/GP5BHDH88
Hard Disk Drive-18GB(Ultra160,10,000rpm)
1"height/Hotplug
GP5-HDH87/GP5BHDH87
Hard Disk Drive-18GB(Ultra160,15,000rpm)
1"height/Hotplug
GP5-HDH8B/GP5BHDH8B
Hard Disk Drive-36GB(Ultra160,10,000rpm)
1"height/Hotplug
GP5-HDH63/GP5BHDH63
F: 6 Go to SCSI Hard Disk Drive as above
RAID Card
(64MB Cache/Ultra2 Wide SCSI/BBU)
GP5-1441/GP5B1441
RAID Card
(32MB Cache/Ultra2 Wide SCSI)
GP5-145/GP5B145
RAID Card
(32MB Cache/Ultra2 Wide SCSI/BBU)
GP5-146/GP5B146
RAID Card
(64MB Cache/Ultra160)
GP5-148/GP5B148
RAID Card
(64MB Cache/Ultra160 )
GP5-150/GP5B150
RAID Card
(64MB Cache/Ultra160/BBU)
GP5-1501/GP5B1501
* GP5-148 RAID Card cannot be installed with other RAID Card
* Only one GP5-148 can be installed in a MS610
SCSI Configuration
Array Configuration
Internal HDD / Internal backup device
33
�MS610M
S610
Connect one backup device (Wide) DLT unit (DLT8000)
G: 4 PG-DL401/PGBDL401*
Onboard SCSI Controller SCSI Cable Two 5" bays are occupied
GP5-849/GP5B849*
Tape Drive SLR100
PG-SL101/PGBSL101*
Tape Drive SLR60
PG-SL601/PGBSL601*
*GP5B849/PGBDL401/PGBSL101/PGBSL601: CTO will be available as of end October.
Connect secondary backup device (Wide) DLT unit (DLT7000)
6 GP5-DL351/GP5BDL351
SCSI Card Two 5" bays are occupied
GP5-127/GP5B127
DAT unit (DDS4)
If mounting two backup devices (Narrow/Wide), SCSI Card (GP5-127) GP5-DT401/GP5BDT401
is required for wide connect device.
If mounting two backup devices (Wide/Wide), SCSI Card (GP5-127)
is required for secondary wide connect device. Tape unit (MLR3)
GP5-ML301/GP5BML301
DAT autoloader (DDS4)
GP5-DTA102/GP5BDTA102
Two 5" bays are occupied
Backup device (Narrow)
4 DLT unit (DLT4000)
Onboard SCSI Controller GP5UDL201/GP5BDL201
Two 5" bays are occupied
DAT unit (DDS3)
GP5UDT301/GP5BDT301
Tape unit
(When Drive Cage Conversion Kit is used) GP5USL501/GP5BSL501
Drive Cage Conversion Kit (for CTO only) DAT autoloader (DDS3)
(HDD Bay: 8bays to 12bays) GP5-DTA101/GP5BDTA101
GP5BBU1 Two 5" bays are occupied
Hard Disk Drive-9GB(Ultra160, 7,200rpm)
H: 3 1"height/Hotplug
Onboard SCSI Controller GP5-HDH9B/GP5BHDH9B
Hard Disk Drive-9GB(Ultra160,10,000rpm)
1"height/Hotplug
GP5-HDH9A/GP5BHDH9A
Hard Disk Drive-18GB(Ultra160, 7,200rpm)
1"height/Hotplug
GP5-HDH88/GP5BHDH88
Hard Disk Drive-18GB(Ultra160,10,000rpm)
1"height/Hotplug
GP5-HDH87/GP5BHDH87
Hard Disk Drive-18GB(Ultra160,15,000rpm)
1"height/Hotplug
GP5-HDH8B/GP5BHDH8B
Hard Disk Drive-36GB(Ultra160,10,000rpm)
1"height/Hotplug
GP5-HDH63/GP5BHDH63
Internal backup device
SCSI Configuration
Max.2 backup devices can be mounted
34
�MS610M
S61
0
I: 6 Go to SCSI Hard Disk Drive as above
RAID Card
(64MB Cache/Ultra2 Wide SCSI/BBU)
GP5-1441/GP5B1441
RAID Card
(32MB Cache/Ultra2 Wide SCSI)
GP5-145/GP5B145
RAID Card
(32MB Cache/Ultra2 Wide SCSI/BBU)
GP5-146/GP5B146
RAID Card
(64MB Cache/Ultra160)
GP5-148/GP5B148
RAID Card
(64MB Cache/Ultra160 )
GP5-150/GP5B150
RAID Card
(64MB Cache/Ultra160/BBU)
GP5-1501/GP5B1501
If mounting two backup devices (Narrow/Wide), SCSI Card (GP5-127) is required for wide connect device.
If mounting two backup devices (Wide/Wide), SCSI Card (GP5-127) is required for secondary wide connect device.
Backup device (Wide) DLT unit (DLT8000)
J: 4 PG-DL401/PGBDL401*
Onboard SCSI Controller SCSI Cable Two 5" bays are occupied
GP5-849/GP5B849*
6 Tape Drive SLR100
SCSI Card DLT unit (DLT7000) PG-SL101/PGBSL101*
GP5-127/GP5B127 GP5-DL351/GP5BDL351
Two 5" bays are occupied
Tape Drive SLR60
DAT unit (DDS4) PG-SL601/PGBSL601*
GP5-DT401/GP5BDT401
*GP5B849/PGBDL401/PGBSL101/PGBSL601:
Tape unit (MLR3) CTO will be available as of end October.
GP5-ML301/GP5BML301
DAT autoloader (DDS4)
GP5-DTA102/GP5BDTA102
Two 5" bays are occupied
Backup device (Narrow)
4 DLT unit (DLT4000)
Onboard SCSI Controller GP5UDL201/GP5BDL201
Two 5" bays are occupied
DAT unit (DDS3)
GP5UDT301/GP5BDT301
Tape unit
GP5USL501/GP5BSL501
DAT autoloader (DDS3)
GP5-DTA101/GP5BDTA101
Two 5" bays are occupied
Max.2 backup devices can bemounted
Array Configuration
Internal backup device
* GP5-148 RAID Card cannot be installed with other RAID Card (Except forGP5-150/1501)
35
�MS610M
S610
LAN Card (1000Base-SX)
K: 6 GP5-183/GP5B183
LAN Card (100Base-TX)
6 GP5-185/GP5B185
LAN Card (100Base-TX Dual port)
6 GP5-186/GP5B186
LAN Card (100Base-TX IPsec)
6 GP5-187/GP5B187
Fibre Channel Card
6 GP5-FC102
Fibre Channel Card
6 GP5-FC101
One PSU can be added Redundant Power Supply Unit
6 GP5UPU161/GP5BUPU161
Server Monitor Module
8 GP5USM103/GP5BUSM103
Others
36
�MS610M
S61
0
Specification
Type
Product ID PGTH2AL1A2 PGTH2AE1A2
CPU Frequency Pentium ® lll Xeon ™ 1GHz Pentium® lll Xeon™ 933MHz
Secondary cache 256KB
Number of CPUs 1 (up to 2)
Memory Standard 256MB (128MB x 2)
Maximum 4GB (1GB x 4)
VRAM 4MB VGA chip: ATI RAGE XL(PCI)
Internal Bays 5-inch Three (one occupied by CD-ROM)
CD-ROM 40X (SCSI)
HDD bay 1inch x 8 (Hotplug)
Available HDD (Ultra160) 9.1GB(10000/7200rpm)/18.2GB(15000/10000/7200rpm)/36.4GB(10000rpm)
Maximum 291.2GB (36.4GB x 8)
Expansion slot PCI64bit 66MHz x2, PCI64bit 33MHz x4, PCI32bit 33MHz x1
SCSI Interface Ultra160 x2
RAID controller Option
Network LAN(10/100 base TX) x 1 (onboard)
Dimension (mm) Pedestal: 332(W)x752(D)x543(H)
Rackmount(7U): 482(W)x710(D)x310(H)
Weight 68kg (max.)
Power consumption 400W (max.)
Power supply One standard units (up to two for redundant)/Hotplug
Mounting Additional Memory
Mount the same capacity DIMM's in units of two.(Mounting of DIMM's with different capacities or a set of less than two DIMM's is not allowed) Mount the DIMM's in ascending order of their capacity. Use DIMM slots in the order from bank 0 to bank1.
� PCI resource areaA part of address area as below is assigned for PCI resource, cannot be used.Operating System Mounted Memory Size The area for PCI resourceWindowsNT®4.0 ~3.4GB No area for PCI resourceWindows®2000 Server 3.4GB ~4.0GB 3.4GB ~4.0GB[Maximum Memory Size:4.0GB]
� Installation of WindowsNT® ServerWindowsNT cannot be installed if more than 2GB memory is mounted in the server.(Please add DIMMs after the installation is completed)
Mounting internal device
� Backplane Pattern
- Standard Drive CageSCSI Channel � � � 1ch
Number of mountable HDD � � � 1inch height Hard Disk Drive x 8 (8HDDs per 1ch)
<Connection illustration>
PRIMERGY H200
Motherboard
BANK0
BANK1
BANK0
BANK1
Slot1A
Slot2
Slot2A
Slot1
Bay1 Bay2 Bay3 Bay4
Bay8 Bay7 Bay6 Bay5
37
�H200H
200
- Upgrade Kit 2-Channels Internal (PGBBU101)SCSI Channel � � � 2ch
Number of mountable HDD � � � 1inch height Hard Disk Drive x 8 (4HDDs per 1ch x 2)
<Connection illustration>
� 5-inch bay installation
Bay3: Used for CD-ROM (SCSI) (Support as standard)Bay2: SCSI ID = 4~5 (Setting on the device side), SCSI ID = 4 (CTO)
DAT(DDS4, DDS3), LTO, Tape Unit(SLR50/60/100), DLT Unit (DLT4000) can be installed in this bayBay1: SCSI ID = 4~5 (Setting on the device side), SCSI ID = 5 (CTO)
DAT(DDS4, DDS3), LTO, DAT Autoloader(DDS4, DDS3), Tape Unit(SLR50/60/100), DLT Unit(DLT7000/8000) can be installed in this bay
Note: A DAT Autoloader, DLT unit installed in 5-inch bay1 will also occupy bay2 because of it's height.SCSI ID 4~5 is selected for each SCSI device mounted in bay1or bay2 (SCSI ID of bay1 and bay2 must be different) SCSI interface of 5inch Cage is Wide. When mounting Narrow connected devices, please use Wide-Narrow conversionConnector (Standard equipment of each device).DLT4000 is mounted in bay2 and bay3 then, CD-ROM is moved to bay1.CD-ROM (standard) must be connected to SCSI connector (Onboard SCSI or SCSI Controller).
Connection of internal HDD and internal backup devicesThe following figure indicates the correct adapters (Onboard SCSI channel, SCSI Controller, etc.) to use to mount devices in H200
Mother Board of H200
Internal HDD Internal SCSI devices
Connection Pattern One device is connected Two devices are connected
Configuration Drive Cage SCSI Host Cable Internal HDD Standard Narrow (*1) x1 Narrow (*1) x2 Narrow(*1) + Wide(*2)
Interface CD-ROM(*3) or Wide(*2) x1 or Wide(*2) x2 connection
connection connection
Onboard Onboard Onboard Onboard
Standard Ultra 160 Onboard SCSI Cable(X1) 1) 9GB, 7,200rpm SCSI (Ch A) SCSI (Ch A) SCSI (Ch A) SCSI (Ch A)
(8Bays/1ch) (Ch B) (Standard 2) 9GB, 10,000rpm Daisy Chain(*4) Daisy Chain(*5) Daisy Chain(*6)
equipment) 3) 18GB, 7,200rpm
4) 18GB, 10,000rpm
SCSI 5) 18GB, 15,000rpm SCSI SCSI SCSI SCSI
Configuration Drive Cage Ultra 160 Onboard SCSI Cable(X2) 6) 36GB, 10,000rpm Controller Controller Controller Controller
Conversion (Ch A/B) (Standard (PG-126) (PG-126) (PG-126) (PG-126)
(8Bays/2ch) equipment) Daisy Chain(*4) Daisy Chain(*5) Daisy Chain(*6)
RAID Controller
Standard Ultra160 PG-142B/142C/ Cable(X1) 1) 9GB, 7,200rpm
(8Bays/1ch) 144B (Ch0) (Standard 2) 9GB, 10,000rpm
Ultra2 Wide 143B (Ch0) equipment) 3) 18GB, 7,200rpm Onboard Onboard Onboard Onboard
Array 4) 18GB, 10,000rpm SCSI (Ch A) SCSI (Ch A) SCSI (Ch A) SCSI (Ch A)
Configuration RAID Controller 5) 18GB, 15,000rpm Daisy Chain(*4) Daisy Chain(*5) Daisy Chain(*6)
Drive Cage Ultra160 PG-142B/142C/ Cable(X2) 6) 36GB, 10,000rpm
Conversion 144B (Ch0/1) (Standard
(8Bays/2ch) Ultra2 Wide 143B (Ch0/1) equipment)
*1 Narrow connect devices: PG-DT301/PG-DTA101/PG-DL201(Wide-Narrow conversion connector is standard equipment with all Narrow connected devices)
*2 Wide connect devices: PG-SL601/PG-SL101/PG-DT401/PG-DTA102/PG-DL351/PG-DL401(SCSI Cable is standard equipment with all Wide connect devices)
*3 Standard CD-ROM drive must be connected to Onboard SCSI Channel or SCSI Controller.
*4 Daisy chain (Onboard SCSI/SCSI Controller - CD-ROM - Narrow/Wide connected device) is available
*5 Daisy chain (Onboard SCSI/SCSI Controller - CD-ROM - Narrow/Wide connected device - Narrow/Wide connected device) is available
*6 Daisy chain (Onboard SCSI/SCSI Controller - CD-ROM - Narrow connected device - Wide connected device) is available
7 In case that more than three backup devices are mounted, PRIMERGY S10 is required (Please refer to the connection table)
Ultra160 Ach
Ultra160 Bch
OnboardSCSI
For HDD/CD-ROM/Backup devices (Wide/Narrow)
For HDD
Bay1 Bay2 Bay3 Bay4
Bay5 Bay6 Bay7 Bay8
38
�H200H
200
Mountable I/O options
H200Maximum
number
Cards Product ID Bus of cards Total REMARKS
mounted
SCSI Controller PG-123 PCI32 2 7 For external SCSI device
(UltraWide HVD)
SCSI Controller PG-126 PCI32 3 For internal Backup device
(Ultra2 Wide LVD)
FibreChannel ControllePG-FC102 PCI64 4
RAID Controller PG-142B PCI64 4
(Ultra160/2ch) 4
RAID Controller PG-142C PCI64 4
(Ultra160/2ch)
RAID Controller PG-143B PCI64 4
(Ultra2 Wide/3ch)
RAID Controller PG-144B PCI64 2
(Ultra160/4ch)
Ethernet Controller PG-183 PCI64 2 Giga LAN (Fibre)
(1000Base-SX) 2
Ethernet Controller PG-188 PCI64 2 3 Giga LAN (Fibre)
(1000Base-SX) Note: Ethernet Controller PG-189 PCI64 3 Up to four PG-142B/142C can be mounted in Windows environment, (1000Base-T) however, up to two can be mounted in other Operating System Ethernet Controller PG-185 PCI32 3 environment.(100Base-TX) PG-144B/PG-189 cannot be installed in PGTH2AL1A/PGTH2AE1ARemote Service Board PGURSB101 PCI32 1 Remote Management PGTH2AL1R/PGTH2AE1R.
Connection Table
PGTH2AL1A2 1CPU(Pentium® lllXeon™ 1GHz/256KB)/Pedestal Type
PGTH2AE1A2 1CPU(Pentium® lllXeon™ 933MHz/256KB)/Pedestal Type
<Items>
Form factor conversion (Pedestal to RackmounGo to A
CPU Field upgrade : Go to B
Pedestal Type Memory addition : Go to C
Standard memory conversion : Go to D
Internal devices
1.SCSI HDD connection Go to E
2. Array HDD connection Go to F
3. Internal backup device Go to G
Others (NIC, PSU, etc.) : Go to H
Rackmount Type
A: Rack Conversion Kit
PGBR1CK3
B:
Max.2CPUs
1 Pentiumlll Xeon 1GHz/133MHz, 256KB SLC (CPU Field Upgrade Kit)
Standard : 1CPU PG-FG10L/PGBFG10L
Pentiumlll Xeon 933MHz/133MHz, 256KB SLC (CPU Field Upgrade Kit)
PG-FG10E/PGBFG10E
CPU
Form factor conversion(Pedestal to Rackmount)
39
�H200H
200
Max.4GB (1GB DIMM x 4) Main Memory 2GB (1GB SDRAM-DIMMx2)
C: 2 PG-RM2A/PGBRM2A
Standard : 256MB (128MB-DIMMx2)
Main Memory 1GB (512MB SDRAM-DIMMx2)
PG-RM1A/PGBRM1A
Main Memory 512MB (256MB SDRAM-DIMMx2)
PG-RM51A/PGBRM51A
Main Memory 256MB (128MB SDRAM-DIMMx2)
PG-RM25A/PGBRM25A
Standard Memory Conversion Kit-2GB (1GB SDRAM-DIMMx2)
D: 2 PGBRU2A
Standard Memory Conversion Kit-1GB (512MB SDRAM-DIMMx2)
PGBRU1A
Standard Memory Conversion Kit-512MB (256MB SDRAM-DIMMx2)
PGBRU51A
3 Standard SCSI Backplane (1inch HDD x 8/1ch)
Split SCSI Backplane Option (1inch HDD x 8/2ch)
Upgrade Kit 2-Channels Internal : PGBBU101
Hard Disk 9GB(Ultra160, 7,200rpm)
E: 3 1"height/Hotplug PG-HDH97A/PGBHDH97A
Onboard SCSI Controller
Hard Disk 9GB(Ultra160,10,000rpm)
1"height/Hotplug PG-HDH91A/PGBHDH91A
Hard Disk 18GB(Ultra160, 7,200rpm)
1"height/Hotplug PG-HDH87A/PGBHDH87A
Hard Disk 18GB(Ultra160,10,000rpm)
1"height/Hotplug PG-HDH81A/PGBHDH81A
Hard Disk 18GB(Ultra160,15,000rpm)
1"height/Hotplug PG-HDH85A/PGBHDH85A
Hard Disk 36GB(Ultra160,10,000rpm)
1"height/Hotplug PG-HDH61A/PGBHDH61A
F: 6 Go to SCSI Hard Disk Drive as above
RAID Controller U160 2Channels
(64MB Cache/Ultra160 SCSI)
PG-142B/PGB142B
RAID Controller U160 2Channels
(64MB Cache/Ultra160 SCSI/Battery Backup)
PG-142C/PGB142C
RAID Controller U2W 3Channels
(64MB Cache/Ultra2 Wide SCSI/Battery Backup)
PG-143B/PGB143B
RAID Controller U160 4Channels
(128MB Cache/Ultra160 SCSI/Battery Backup)
PG-144B/PGB144B
Array Configuration
SCSI Configuration
Memory
40
�H200H
200
* Standard CD-ROM drive must be connected to Onboard SCSI Channel or SCSI Controller.
Tape Drive DLT8000
F: 4 PG-DL401/PGBDL401
Onboard SCSI Controller Max.2 backup devices can be mounted Two 5" bays are occupied
6 Tape Drive DLT7000
SCSI Controller U2W PG-DL351/PGBDL351
PG-126/PGB126 Two 5" bays are occupied
In case that "Upgrade Kit 2-Channels Internal (PGBBU101)" Tape Drive DLT4000
is applied, "SCSI Controller U2W (PG-126/PGB126)" is required PG-DL201/PGBDL201
for connecting backup devices Two 5" bays are occupied
Tape Drive LTO
PG-LT101/PGBLT101
6 Tape Drive SLR100
SCSI Controller U2W PRIMERGY S10 PG-SL101/PGBSL101
PG-126/PGB126 SCSI Cable PGUR1BC3
PG-CBLS001 Max.4 backup devices
can be mounted in S10 Tape Drive SLR60
PG-SL601/PGBSL601
SCSI Cable
PG-CBLS002 Tape Drive SLR50
PG-ML301/PGBML301
SCSI Cable Tape Drive DAT DDS4
PG-CBLS003 PG-DT401/PGBDT401
PRIMERGY S10 is required in case that more than three
backup devices are mounted. Tape Drive DAT DDS3
PG-DT301/PGBDT301
Tape Drive DAT DDS4 Autoloader
PG-DTA102/PGBDTA102
Two 5" bays are occupied
Tape Drive DAT DDS3 Autoloader
PG-DTA101/PGBDTA101
Two 5" bays are occupied
Gigabit Ethernet Controller (1000Base-SX)
H: 6 PG-183/PGB183
Gigabit Ethernet Controller (1000Base-SX)
6 PG-188/PGB188
Gigabit Ethernet Controller (1000Base-T)
6 PG-189/PGB189
Fast Ethernet Controller (100Base-TX)
6 PG-185/PGB185
Fibre Channel Controller
6 PG-FC102
Remote Service Board Kit A Remote Service Board
6 PG-RSBOP1 PGURSB101
One PSU can be added Power Supply Module
6 (Redundant Power Supply Unit)
PG-PU101/PGBPU101
Others
Internal backup device
41
�H200H
200
Specification
Type Pedestal
Product ID GP5T3DL1A GP5T3DE1A
CPU Pentium® lll
Frequency 1BGHz 933MHz
Secondary cache 256KB
Number of CPUs 1 (up to 2)
Memory Standard 256MB (256MB x 1)
Maximum 4GB (1GB x 4)
VRAM 4MB VGA chip: ATI RAGE XL(PCI)
Internal Bays 5-inch Three (one occupied by CD-ROM)
CD-ROM 40X (ATAPI)
HDD bay 1inch x 5 (Hotplug)
Available HDD (Ultra160) 9.1GB(10000rpm)/18.2GB(15000/10000rpm)/36.4GB(10000rpm)
Available HDD (Ultra2 Wide) 9.1GB(7200rpm)/18.2GB(7200rpm)
Maximum 182.0GB (36.4GB x 5)
Expansion slot PCI64bit 33MHz x4, PCI32bit 33MHz x2
SCSI Interface Ultra160 x1, Ultra160 or Narrow x1
RAID controller Option
Network LAN(10/100 base TX) x 1 (onboard)
Dimension (mm) Pedestal: 174(W)x615(D)x449(H)
Rackmount(4U): 482(W)x565(D)x174(H)
Weight Pedestal:32kg/Rackmount:35kg
Power consumption 340W (max.)
Power supply One standard units (up to two for redundant)
The mother board has four slots for RAM modules (including base memory), install RAM modules in slot number order.
� PCI resource areaA part of address area as below is assigned for PCI resource, cannot be used.Operating System Mounted Memory Size The area for PCI resourceWindowsNT®4.0 ~3.5GB No area for PCI resourceWindows®2000 Server 3.5GB ~4.0GB 3.68GB ~4.0GB[Maximum Memory Size:4.0GB]
� Installation of WindowsNT® ServerWindowsNT cannot be installed if more than 2GB memory is mounted in the server.(Please add DIMMs after the installation is completed)
- ES320 has five HDD bays and 36.4GB/18.2GB/9.1GB HDD (1"height) can be mounted. - When DLT unit (GP5UDL201) is installed, DLT Enclosure (GP5-BC2) is required.
� 5-inch bay installation
Bay1: Used for CD-ROM (IDE) (Support as standard)Bay2: SCSI ID = 4~6 (Setting on the device side), SCSI ID = 4 (CTO)
DAT (DDS4, DDS3), Tape Unit(MLR3, SLR5) can be installed in this bayBay3: SCSI ID = 4~6 (Setting on the device side), SCSI ID = 5 (CTO)
DAT(DDS4, DDS3), DAT Autoloader(DDS4, DDS3), DLT Unit(DLT4000) can be installed in this bayNote: SCSI IDs of the devices installed in bay2 and bay3 must be different.Even if bays 2 or 3 are not used, the appropriate Narrow SCSI Cable must be connected.A DAT Autoloader, DLT unit is installed in bay3 and also occupies bay2.When installing a Narrow SCSI device in a system already containing a Wide SCSI devices, connect the Narrow device to the Narrow Onboard channel and reconnect the Wide device to a separate SCSI Card.
Mounting internal SCSI devices
PRIMERGY ES320
Mounting additional memory
42
�ES320E
S32
0
Connection of internal HDD and internal backup devices
Mother Board of ES320
Internal HDD Internal backup device (Max.2)
Connection Pattern One device is connected Two devices are connected
Connection SCSI Host Cable Internal HDD Narrow Wide Narrow device Wide device Narrow device and
Interface connect connect x 2 x 2 *3 Wide device *4
device*1 device*2
SCSI Cable Narrow device:
Ultra160 Onboard SCSI (Standard 1)9GB,7,200rpm Narrow-1,2 Wide-1 Onboard
SCSI Configuration equipment) 2)18GB,7,200rpm Onboard Onboard Onboard SCSI SCSI(Nallow)
3)9GB,10,000rpm SCSI(Nallow) SCSI (Wide) Onboard Wide-2
RAID Card 4)18GB,10,000rpm connection SCSI(Nallow) SCSI Card Wide device:
Ultra2 Wide GP5-143/1441/145/146 SCSI Cable 5)18GB,15,000rpm Daisy chain (GP5-127) SCSI Card(GP5-127)
Array Configuration (Ch0) (Standard 6)36GB,10,000rpm connection
equipment)
Ultra160 GP5-148/150/1501/151
(Ch0)
*1 Narrow connect devices: GP5UDL201/GP5UDT301/GP5USL501/GP5-DTA101
*2 Wide connect devices: GP5-DT401/GP5-DTA102/GP5-ML301/GP5-DL351(SCSI Cable is standard equipment), PG-SL101/PG-SL601 (SCSI Cable is required)
*3 Daisy chain (Wide connect device - Wide connect device) is not available
*4 Daisy chain (Wide connect device - Narrow connect device) is not available
SCSI Cable is standard equipment (Narrow: Main unit/Wide: Backup device)
Mountable I/O options
ES320Maximum Restrictionsnumber - When GP5-186 is mounted, one other LAN Card
Cards Product ID Bus of cards Total REMARKS (GP5-183/185/187/188/189) can be mounted.mounted - Only one GP5-148 can be mounted in a server.
SCSI card GP5-127 PCI32 3 3 External HDD (This restriction will be eliminated later)(Ultra2 Wide LVD) 3
Fibre Channel Card GP5-FC101 PCI64 2 *1: One GP5-1441 can be mounted in GP5T3CL1A(R)/ GP5T3CE1A(R)/GP5T3CB1A(R)
RAID card GP5-143 PCI32 1 2 6 Internal array *2: GP5-150/1501/151 cannot be mounted in GP5T3CL1A(R)/(Ultra2 Wide LVD) GP5T3CE1A(R)/GP5T3CB1A(R) RAID card GP5-1441 PCI64 2 *1 Internal/External array
(Ultra2 Wide LVD)
RAID card GP5-145/146 PCI64 2 Internal/External array
(Ultra2 Wide LVD)
RAID card GP5-148 PCI64 2 Internal/External array
(Ultra160)
RAID card GP5-150/1501 PCI64 2 *2 Internal/External array
(Ultra160)
RAID card GP5-151 PCI32 1 *2 Internal array
(Ultra160)
LAN card GP5-183 PCI64 2 Giga LAN
(1000Base-SX)
LAN card GP5-188 PCI64 2 Giga LAN
(1000Base-SX)
LAN card GP5-189 PCI64 2 Giga LAN
(1000Base-T) 3
LAN card GP5-185 PCI32 3
(100Base-TX)
LAN card GP5-186 PCI32 1 Dual Port LAN
(100Base-TX)
LAN card GP5-187 PCI32 3 IPsec LAN
(100Base-TX)
Server Monitor Module GP5USM103 PCI32 1 1
Narrow
Wide A
Wide BOnboardSCSI
For backup device (Narrow)
For HDD
For Backup device (Wide)Select either of the SCSI channel
43
�ES320E
S320
Connection Table
PRIMERGY ES320
GP5T3DL1A 1CPU/Pedestal Type 1CPU (Pentium® lll 1BGHz), Memory:256MB(ECC), HDD:Option
GP5T3DE1A 1CPU/Pedestal Type 1CPU (Pentium® lll 933MHz), Memory:256MB(ECC), HDD:Option
<Items>
Form factor conversion (Pedestal to Rackmount) Go to A
CPU Field Upgrade : Go to B
Memory addition : Go to C
Internal Hard Disk Drive connection
(Pedestal type) 1. SCSI connection Go to D
2. Array connection Go to E
(Rackmount type)
Internal Backup devices Go to F
Others (NIC etc.) Go to G
A: Rack Conversion Kit
PGBR1CK2
Max : 2CPUs CPU Field Upgrade Kit-81 (Pentium III-1BGHz (256KB) x1)
B: 1 GP5-FG21L/GP5BFG21L
Standard memory : 1CPU
CPU Field Upgrade Kit-80 (Pentium III-933MHz (256KB) x1)
GP5-FG21E/GP5BFG21E
Max.4GB
C: 2 Additional Memory - 128MB (128MB SDRAM-DIMM x1)
Standard memory : 256MB (256MB SDRAM-DIMM x1) GP5-RM12M/GP5BRM12M
Additional Memory - 256MB (256MB SDRAM-DIMM x1)
GP5-RM25M/GP5BRM25M
Additional Memory - 512MB (512MB SDRAM-DIMM x1)
GP5-RM51M/GP5BRM51M
Additional Memory - 1GB (1GB SDRAM-DIMM x1)
GP5-RM1M/GP5BRM1M
2 Standard Memory Conversion Kit-1GB (1GB SDRAM-DIMMx1)
GP5BRU1GE
Standard Memory Conversion Kit-512MB (512MB SDRAM-DIMMx1)
GP5BRU51J
Memory
CPU
Standard Memory Conversion
Form factor conversion(Pedestal to Rackmount)
44
�ES320E
S32
0
(1)Disk Addition / Duplexing Up to 5 disks Hard Disk Drive - 9GB (Ultra2 Wide, 7,200rpm) (Hot Plug)
D: 3 GP5-HDH9C/GP5BHDH9C
Onboard SCSI Controller
Hard Disk Drive - 9GB (Ultra160,10,000rpm) (Hot Plug)
GP5-HDH9D/GP5BHDH9D
Hard Disk Drive -18GB (Ultra2 Wide, 7,200rpm) (Hot Plug)
GP5-HDH89/GP5BHDH89
Hard Disk Drive -18GB (Ultra160, 10,000rpm) (Hot Plug)
GP5-HDH8A/GP5BHDH8A
Hard Disk Drive - 18GB (Ultra160, 15,000rpm) (Hot Plug)
GP5-HDH8B/GP5BHDH8B
Hard Disk Drive - 36GB (Ultra160, 10,000rpm) (Hot Plug)
GP5-HDH63/GP5BHDH63
(2)Internal Disk Array
Hard Disk Drive - 9GB (Ultra2 Wide, 7,200rpm) (Hot Plug)
E: 6 RAID Card (Cache : 8MB, Ultra2 Wide SCSI) GP5-HDH9C/GP5BHDH9C
GP5-143/GP5B143
Hard Disk Drive - 9GB (Ultra160,10,000rpm) (Hot Plug)
RAID Card (Cache : 64MB, Ultra2 Wide SCSI, BBU) GP5-HDH9D/GP5BHDH9D
GP5-1441/GP5B1441
Hard Disk Drive -18GB (Ultra2 Wide, 7,200rpm) (Hot Plug)
RAID Card (Cache :16MB, Ultra2 Wide SCSI) GP5-HDH89/GP5BHDH89
GP5-145/GP5B145
Hard Disk Drive -18GB (Ultra160, 10,000rpm) (Hot Plug)
RAID Card (Cache :16MB, Ultra2 Wide SCSI, BBU) GP5-HDH8A/GP5BHDH8A
GP5-146/GP5B146
Hard Disk Drive - 18GB (Ultra160, 15,000rpm) (Hot Plug)
RAID Card (Cache :64MB, Ultra160) GP5-HDH8B/GP5BHDH8B
GP5-148/GP5B148
Hard Disk Drive - 36GB (Ultra160, 10,000rpm) (Hot Plug)
RAID Card (Cache :64MB, Ultra160 SCSI) GP5-HDH63/GP5BHDH63
GP5-150/GP5B150
RAID Card (Cache :64MB, Ultra160, BBU)
GP5-1501/GP5B1501
RAID Card (Cache :32MB, Ultra160)
GP5-151/GP5B151
* GP5-148 RAID Card cannot be installed with other RAID Card
* Only one GP5-148 can be installed in a ES320
Internal Hard Disk
45
�ES320E
S320
Backup device (Wide)
F: 4 Tape unit (MLR3)
Onboard SCSI Controller GP5-ML301/GP5BML301
6 DAT unit (DDS4)
GP5-DT401/GP5BDT401
SCSI Card
GP5-127/GP5B127
DAT autoloader (DDS4)
GP5-DTA102/GP5BDTA102
Two 5" bays are occupied
Tape Drive SLR100
PG-SL101/PGBSL101*
SCSI Cable
GP5-849/GP5B849* Tape Drive SLR60
PG-SL601/PGBSL601*
*GP5B849/PGBSL101/PGBSL601: CTO will be available as of end October.
Backup Device (Narrow) DLT unit (DLT4000)
4 GP5UDL201/GP5BDL201
Onboard SCSI Controller *DLT Enclosure (GP5-BC2) is required to install DLT4000
Two 5" bays are occupied
DAT unit (DDS3)
GP5UDT301/GP5BDT301
Tape unit (EDT20)
GP5-NS202/GP5BNS202
Tape unit (SLR5)
GP5USL501/GP5BSL501
LAN Card (1000Base-SX)
G: 6 GP5-183/GP5B183 DAT autoloader (DDS3)
GP5-DTA101/GP5BDTA101
Two 5" bays are occupied
LAN Card (1000Base-SX)
6 GP5-188/GP5B188
LAN Card (1000Base-T)
6 GP5-189/GP5B189
LAN Card (100Base-TX)
6 GP5-185/GP5B185
LAN Card (100Base-TX Dual port)
6 GP5-186/GP5B186
LAN Card (100Base-TX IPsec)
6 GP5-187/GP5B187
Fibre Channel Card
6 GP5-FC101
8 Redundant Power Supply Unit
GP5UPU151/GP5BUPU151
6 Server Monitor Module
GP5USM103/GP5BUSM103
Internal Backup Devices
Others
Max.2 backup devices can bemounted
46
�ES320E
S32
0
Specification
Type Pedestal
Product ID PGTC2AE1A PGTC2AL1A
CPU Pentium®lll
Frequency 933MHz 1BGHz
Secondary cache 256KB
Number of CPUs 1 (up to 2)
Memory Standard 256MB (128MB x 2)
Maximum 2GB (512MB x 4)
VRAM 8MB VGA chip: ATI RAGE XL(PCI)
Internal Bays 5-inch Two (one occupied by CD-ROM)
CD-ROM 48X (ATAPI)
HDD bay 1inch x 4* (Non Hot-plug: Standard)
(Hot-plug: Option)
Available HDD (Ultra160) 9.1GB(10000rpm)/18.2GB(10000rpm)/36.4GB(10000rpm)
Maximum 145.6GB(36.4GB x4)
Expansion slot PCI64bit 66MHz x2, PCI64bit 33MHz x2, PCI32bit 33MHz x2
SCSI Interface Ultra 160 x1
RAID controller Option
Network LAN(10/100 base TX) x 1 (onboard)
Dimension (mm) Pedestal: 204(W)x460(D)x428(H)
Rackmount(5U): 446(W)x516(D)x205(H)
Weight (max.) Pedestal: 19.7kg /Rackmount: 23.4kg
Power consumption (max.) 302W
Power supply One (No Redundant)
* Form factor conversion from Pedestal to Rackmountable is available with an option
The mother board has four slots for RAM modules (including base memory), install RAM modules in slot number order.
- B225 have four HDD bays, and 9GB/18GB/36GB HDD (1"height) can be mounted. - HDD can be connected to Onboard SCSI Controller or RAID Controller. (SCSI Cable is standard equipment) - In case of Onboard SCSI configuration, SCSI Card (PG-128) is required to mount backup device.
� 5-inch bay installation
Bay1: Used for CD-ROM (IDE) (Support as standard)Bay2: SCSI ID = 5 (Fixed)
DAT (DDS4, DDS3), SLR(SLR60, SLR100) can be installed in this bay
PRIMERGY B225
Mounting additional memory
Mounting internal SCSI devices
47
�B225B
225
Connection of internal HDD and internal backup devices
Mother Board of B225There is one SCSI channels and two EIDE channels on the Motherboard
Internal HDD Internal backup device (Max:1)
Connection Pattern
Connection SCSI Backplane Interface Required option
Required option Available HDD
Non Hot-plug Standard Ultra160 Onboard SCSI 1)9GB,10,000rpm SCSI Controller
SCSI 2)18GB,10,000rpm PG-128
Configuration 3)36GB,10,000rpm SCSI Cable
PG-CBLS014
Hot-plug Option
SCSI Hotplug Drive Cage
Configuration PGBBU104
Non Hot-plug Standard Ultra160 RAID Controller 1)9GB,10,000rpm Onboard SCSI Controller
RAID PG-141B/142B/142C 2)18GB,10,000rpm SCSI Cable
Configuration 3)36GB,10,000rpm PG-CBLS014
Hot-plug Option
RAID Hotplug Drive Cage
Configuration PGBBU104
* Wide - Narrow converter is equipped in Narrow connect backup device (PG-DT301).
Mountable I/O options
B225Maximum
number
Cards Product ID Bus of cards Total REMARKS
mounted
SCSI Controller PG-128 PCI64/32 3 For Backup device/External device
(Ultra160)
RAID Controller PG-141B PCI32 1 3 For Internal array configuration
(Ultra160 1ch) 2 6
RAID Controller PG-142B/142C PCI64 1 For Internal/External array configuration
(Ultra160 2ch)
Ethernet Controller PG-185 PCI64/32 3
(100Base-TX)
Ethernet Controller PG-188 PCI64/32 2 3 Giga LAN (Fibre)
(1000Base-SX)
Ethernet Controller PG-189 PCI64/32 2 Giga LAN (Copper)
(1000Base-T)
Remote Service Board PGURSB101 PCI32 1 1 For Remote Management
Ultra160 For HDD/Backup deviceOnboardSCSI Controller
48
�B225B
225
Connection Table
PGTC2AL1A: 1CPU(Pentium®lll1BGHz)/Pedestal Type
PGTC2AE1A: 1CPU(Pentium®lll933MHz)/Pedestal Type
<Items>
Form factor conversion (Pedestal to Rackmount) Go to A
CPU Field Upgrade : Go to B
Memory addition : Go to C
Pedestal Type Standard memory conversion : Go to D
Internal HDD (Non Hotplug SCSI)
SCSI Configuration : Go to E
RAID Configuration : Go to F
Internal HDD (Hotplug SCSI)
SCSI Configuration : Go to G
RAID Configuration : Go to H
Internal backup device : Go to I
Rack Type Others (NIC, PSU, etc.) : Go to J
Rack Conversion Kit
A: PGBR1CK1
B:
Max : 2CPUs
1 Pentiumlll 1BGHz/133MHz, 256KB SLC (CPU Field Upgrade Kit)
PG-FG11L/PGBFG11L
Pentiumlll 933MHz/133MHz, 256KB SLC (CPU Field Upgrade Kit)
PG-FG11E/PGBFG11E
Max:2GB ((512MB SDRAM-DIMM x 2) x2)
C: 2 Main Memory 1GB (512MB SDRAM DIMMx2)
Standard:256MB (128MB SDRAM-DIMMx2) PG-RM1D/PGBRM1D
Main Memory 512MB (256MB SDRAM DIMMx2)
PG-RM51D/PGBRM51D
Main Memory 256MB (128MB SDRAM DIMMx2)
PG-RM25D/PGBRM25D
Standard Memory conversion option
D: 2 Standard Memory Conversion Kit-1GB (512MB SDRAM-DIMMx2)
PGBRU1D
Standard Memory Conversion Kit-512MB (256MB SDRAM-DIMMx2)
PGBRU51D
Memory
CPU
Form factor conversion(Pedestal to Rackmount)
49
�B225B
225
Max: 4 HDDs Hard Disk 9GB(Ultra160/10,000rpm/Non Hotplug)
E: 3 PG-HD9G1C/PGBHD9G1C
Onboard SCSI Controller
Hard Disk 18GB(Ultra160/10,000rpm/Non Hotplug)
PG-HD8G1C/PGBHD8G1C
Hard Disk 36GB(Ultra160/10,000rpm/Non Hotplug)
PG-HD6G1C/PGBHD6G1C
F: 6 Go to the same HDD as SCSI configuration
RAID Controller U160 1Channel
(32MB Cache/Ultra160)
PG-141B/PGB141B
RAID Controller U160 2Channels
(64MB Cache/Ultra160)
PG-142B/PGB142B
RAID Controller U160 2Channels
(64MB Cache/Ultra160/BBU)
PG-142C/PGB142C
3 Hotplug Drive Cage
PGBBU104
Max: 4 HDDs Hard Disk 9GB(Ultra160/10,000rpm/Hotplug)
G: 3 PG-HDH91C/PGBHDH91C
Onboard SCSI Controller
Hard Disk 18GB(Ultra160/10,000rpm/Hotplug)
PG-HDH81C/PGBHDH81C
Hard Disk 36GB(Ultra160/10,000rpm/Hotplug)
PG-HDH61C/PGBHDH61C
H: 6 Go to the same HDD as SCSI configuration
RAID Controller U160 1Channel
(32MB Cache/Ultra160)
PG-141B/PGB141B
RAID Controller U160 1Channel
(64MB Cache/Ultra160)
PG-142B/PGB142B
RAID Controller U160 2Channels
(64MB Cache/Ultra160/BBU)
PG-142C/PGB142C
RAID Configuration
SCSI Configuration
RAID Configuration
Internal HDD (Non Hotplug SCSI )
Internal HDD (Hotplug SCSI )
SCSI Configuration
50
�B225B
225
One backup device can be mounted
I: 4 Tape Drive DAT DDS4
Onboard SCSI Controller PG-DT401/PGBDT401
* In case of RAID configuration
Tape Drive DAT DDS3
PG-DT301/PGBDT301
6 Tape Drive SLR100
PG-SL101/PGBSL101
SCSI Controller
PG-128/PGB128
* In case of SCSI configuration Tape Drive SLR60
PG-SL601/PGBSL601
Tape Drive DLT8000
6 PG-DL401/PGBDL401
SCSI Controller U2W Two 5" bays are occupied
PG-128/PGB128 SCSI Cable PRIMERGY S10
PG-CBLS001 PGUR1BC3 Tape Drive DLT7000
Max.4 backup devices PG-DL351/PGBDL351
can be mounted in S10 Two 5" bays are occupied
SCSI Cable Tape Drive DLT4000
PG-CBLS002 PG-DL201/PGBDL201
Two 5" bays are occupied
Tape Drive LTO
SCSI Cable PG-LT101/PGBLT101
PG-CBLS003
Tape Drive SLR100
PG-SL101/PGBSL101
Tape Drive SLR60
PG-SL601/PGBSL601
Tape Drive SLR50
PG-ML301/PGBML301
Tape Drive DAT DDS4
PG-DT401/PGBDT401
Tape Drive DAT DDS3
PG-DT301/PGBDT301
Tape Drive DAT DDS4 Autoloader
Fast Ethernet Controller (100Base-TX) PG-DTA102/PGBDTA102
J: 6 PG-185/PGB185 Two 5" bays are occupied
Tape Drive DAT DDS3 Autoloader
Gigabit Ethernet Controller (1000Base-SX) PG-DTA101/PGBDTA101
6 PG-188/PGB188 Two 5" bays are occupied
Gigabit Ethernet Controller (1000Base-T)
6 PG-189/PGB189
Fibre Channel Controller
6 PG-FC102
Remote Service Board Kit C Remote Service Board
6 PG-RSBOP3 PGURSB101
Internal backup device
Others
51
�B225B
225
Specification
Type Pedestal
Product ID PGTC1AE1A PGTC1AM1A
CPU Frequency Pentium®lll 933MHz Celeron™ 766MHz
Secondary cache 256KB 128KB
Number of CPUs 1
Memory Standard 128MB(128MB x1)
Maximum 1.5GB(512MB x3)
Internal Bays 5-inch Two (One occupied by CD-ROM)
CD-ROM 48X (ATAPI)
HDD bay 1inch x 4 (Non Hotplug)
Available HDD (Ultra160) 9.1GB(10000rpm)/18.2GB(10000rpm)/36.4GB(10000rpm)
(ATA66) 40GB (5,400/7,200rpm)
Maximum 145.6GB (36.4GB x4)
Expansion slot PCI32bit 33MHz x4
SCSI Controller Option
RAID controller Option
Network LAN(10/100 base TX) x 1 (onboard)
Dimension (mm) 204(W)x460(D)x428(H)
Weight 18.3kg (max.)
Power consumption 273W (max.)
Power supply One (No Redundant)
The mother board has three slots for RAM modules (including base memory), install RAM modules in slot number order.
- B125 have four HDD bays, and 9GB/18GB/36GB HDD (1"height) can be mounted. - In case of SCSI configuration, SCSI Controller (PG-128) and SCSI Cable (PG-CBLS013) are required to mount SCSI HDD, and the SCSI Controller is also used for connection with backup device (SCSI Cable PG-CBLS014 is required). Please refer to the figure below;
� 5-inch bay installation
Bay1: Used for CD-ROM (IDE) (Support as standard)Bay2: SCSI ID = 5 (Fixed)
DAT (DDS4, DDS3), Tape Unit (SLR50, SLR60, SLR100) can be installed in this bay
Mounting additional memory
PRIMERGY B125
Mounting internal SCSI devices
SCSI Controller (PG-128)
Ultra160 SE/LVD
SCSI CablePG-CBLS013
SCSI CablePG-CBLS014 Backup device
52
�B125B
125
Connection of internal HDD and internal backup devices
Mother Board of B125There are two EIDE channels on Motherboard
Internal HDD Internal backup device (Max:1)
Connection Pattern
Internal HDD Interface Required option
Required option Available HDD
SCSI Ultra160 SCSI Controller (PG-128) 1)9GB,10,000rpm SCSI Controller (PG-128)
Configuration SCSI Cable(PG-CBLS013) 2)18GB,10,000rpm SCSI Cable(PG-CBLS014)
3)36GB,10,000rpm (SCSI Controller can be shared
by both HDD and backup device)
IDE IDE Onboard Primary IDE 1)40GB, 5400rpm
Configuration ATA66 Controller 2)40GB, 7,200rpm SCSI Controller (PG-128)
SCSI Cable(PG-CBLS014)
RAID Ultra160 RAID Controller (PG-141B) 1)9GB,10,000rpm
Configuration SCSI Cable(PG-CBLS013) 2)18GB,10,000rpm
3)36GB,10,000rpm
* Wide - Narrow converter is equipped in Narrow connect backup device (PG-DT301).
Mountable I/O options
B125Maximum
number
Cards Product ID Bus of cards Total REMARKS
mounted
RAID Controller PG-141B PCI32 1 4 Internal RAID configuration
(Ultra160) 3
SCSI Controller PG-128 PCI32 3 Internal HDD/Backup device
(Ultra160)
Ethernet Controller PG-185 PCI64 3
(100Base-TX) 3*
Ethernet Controller PG-188 PCI32 2 Giga LAN (Fibre)
(1000Base-SX)
Ethernet Controller PG-189 PCI32 2 Giga LAN (Copper)
(1000Base-T)
Remote Service Board PGURSB101 PCI32 1 For Remote Management
* Up to three controllers can be mounted within the combination of PG-128/PG-188/PG-189
Secondary EIDE
Primary EIDE
OnboardIDE Controller
For CD-ROM
For HDD
53
�B125B
125
Connection Table
PGTC1AE1A: 1CPU(Pentium®lll933MHz)/Pedestal Type
PGTC1AM1A: 1CPU(Celeron™766MHz)/Pedestal Type
<Items>
Memory addition : Go to A
Standard memory conversion : Go to B
Internal HDD/Internal backup device
SCSI Configuration : Go to C
RAID Configuration : Go to D
IDE Configuration : Go to E
Internal backup device Go to F
Others (NIC, PSU, etc.) : Go to G
Max:1.5GB (512MB SDRAM-DIMM x 3) Main Memory 512MB (512MB SDRAM DIMMx1)
A: 2 PG-RM51E/PGBRM51E
Standard:128MB (128MB SDRAM-DIMMx1)
Main Memory 256MB (256MB SDRAM DIMMx1)
PG-RM25E/PGBRM25E
Main Memory 128MB (128MB SDRAM DIMMx1)
PG-RM12E/PGBRM12E
Standard Memory conversion option
B: 2 Standard Memory Conversion Kit-512MB (512MB SDRAM-DIMMx1)
PGBRU51E
Standard Memory Conversion Kit-256MB (256MB SDRAM-DIMMx1)
PGBRU25E
Max: 4 HDDs Hard Disk 9GB(Ultra160/10,000rpm/Non Hotplug)
C: 3 PG-HD9G1C/PGBHD9G1C
SCSI Controller SCSI Cable
PG-128/PGB128 PG-CBLS013/PGBCBLS013
Hard Disk 18GB(Ultra160/10,000rpm/Non Hotplug)
PG-HD8G1C/PGBHD8G1C
Hard Disk 36GB(Ultra160/10,000rpm/Non Hotplug)
PG-HD6G1C/PGBHD6G1C
Max: 4 HDDs
D: 6 Go to the same HDD as SCSI configuration
RAID Controller U160 1Channel SCSI Cable
(32MB Cache/Ultra160) PG-CBLS013/PGBCBLS013
PG-141B/PGB141B
Max: 2 HDDs Hard Disk 40GB(ATA66/7,200rpm)
E: 3 PG-HD4E7C/PGBHD4E7C
3
Hard Disk 40GB(ATA66/5,400rpm)
PG-HD4E5C/PGBHD4E5C
Memory
SCSI Configuration
RAID Configuration
Internal HDD / Internal backup device
IDE Configuration
54
�B125B
125
One backup device can be mounted
F: 6 Tape Drive DAT DDS4
SCSI Controller SCSI Cable PG-DT401/PGBDT401
PG-128/PGB128 PG-CBLS014/PGBCBLS014
Tape Drive DAT DDS3
* One SCSI Controller (PG-128) can be used for connection both HDD and Backup device. PG-DT301/PGBDT301
Tape Drive SLR100
PG-SL101/PGBSL101
Tape Drive SLR60
PG-SL601/PGBSL601
Fast Ethernet Controller (100Base-TX)
G; 6 PG-185/PGB185
Gigabit Ethernet Controller (1000Base-SX)
6 PG-188/PGB188
Gigabit Ethernet Controller (1000Base-T)
6 PG-189/PGB189
Remote Service Board Kit D Remote Service Board
6 PG-RSBOP4 PGURSB101
Others
Internal backup device
55
�B125B
125
<PRIMERGY N800/N400/H200 - GR720>
Fibre Channel Controller Fibre Channel Cable
6 PG-FC102 GP5-311 (2m)/312(5m)/313(15m)
Fibre Channel Controller Fibre Channel Cable
6 PG-FC102 GP5-311 (2m)/312(5m)/313(15m)
6
Ethernet Controller
PG-185/PGB185
Fast Ethernet Cable
DCL-FEA05U
Ethernet Controller
6 PG-185/PGB185
Fibre Channel Controller Fibre Channel Cable
6 PG-FC102 GP5-311 (2m)/312(5m)/313(15m)
Fibre Channel Controller Fibre Channel Cable
6 PG-FC102 GP5-311 (2m)/312(5m)/313(15m)
<PRIMERGY MS610 - GR720>
Fibre Channel Card Fibre Channel Cable
6 GP5-FC101 GP5-311 (2m)/312(5m)/313(15m)
Fibre Channel Card Fibre Channel Cable
6 GP5-FC101 GP5-311 (2m)/312(5m)/313(15m)
6
Cluster Kit 4
GP5S634
- Fast Ethernet Cable
- LAN Card x 2
6
Fibre Channel Card Fibre Channel Cable
6 GP5-FC101 GP5-311 (2m)/312(5m)/313(15m)
Fibre Channel Card Fibre Channel Cable
6 GP5-FC101 GP5-311 (2m)/312(5m)/313(15m)
Configuration of Microsoft® Clustering
Controller ofDisk Array(Primary)
Controller ofDisk Array(Secondary)
Disk Array FUJITSUGR720
PRIMERGY N800PRIMERGY N400
PRIMERGY H200
PRIMERGY N800PRIMERGY N400
PRIMERGY H200
Controller ofDisk Array(Primary)
Controller ofDisk Array(Secondary)
PRIMERGY MS610
PRIMERGY MS610
Disk Array FUJITSUGR720
56
�ClusteringC
lust
erin
g
<PRIMERGY N800/N400/H200 - EMC® Clariion®/Symmetrix®>
6 Emulex LP8000 Fibre Channel Cable
6 Emulex LP8000 Fibre Channel Cable
6
Ethernet Controller
PG-185/PGB185
Fast Ethernet Cable
DCL-FEA05U
Ethernet Controller
6 PG-185/PGB185
6 Emulex LP8000 Fibre Channel Cable
6 Emulex LP8000 Fibre Channel Cable
Please contact your local FUJITSU sales representative in the case as follows; - In case of connecting with EMC disk array, each component surrounded by ("Fibre Channel Card with driver SW", "Fibre Channel Cable", "Fibre Channel Switch") should be EMC's. - Certified configuration
Controller ofDisk Array(Primary)
Controller ofDisk Array(Secondary)
Disk Array
PRIMERGY N800PRIMERGY N400
PRIMERGY H200
PRIMERGY N800PRIMERGY N400
PRIMERGY H200
EMC®� Clariion® FC5300 Clariion® FC4500 Symmetrix®8000
57
�ClusteringC
lustering
RAID Controller U160 2Channels SCSI cable
6 (64MB Cache/Ultra160) PG-CBLS004(2m)/005(5m)/006(10m)
PG-142B/PGB142B
RAID Controller U160 2Channels SCSI cable
6 (64MB Cache/Ultra160) PG-CBLS004(2m)/005(5m)/006(10m)
PG-142C/PGB142C
RAID Controller U2W 3Channels SCSI cable
6 (64MB Cache/Ultra2 Wide) PG-CBLS004(2m)/005(5m)/006(10m)
PG-143B/PGB143B
PRIMERGY S30 (Pedestal)
RAID Controller U160 4Channels SCSI cable
6 (128MB Cache/Ultra160) PG-CBLS004(2m)/005(5m)
PG-144B/PGB144B
RAID card SCSI cable
6 (64MB Cache/Ultra160) PG-CBLS004(2m)/005(5m)/006(10m)
GP5-150/GP5B150
RAID card SCSI cable
6 (64MB Cache/Ultra160/BBU) PG-CBLS004(2m)/005(5m)/006(10m)
GP5-1501/GP5B1501
Inside of PRIMERGY S30
Hard Disk 9GB Hard Disk 18GB
(7,200rpm) (15,000rpm)
PG-HDH97B/PGBHDH97B PG-HDH85B/PGBHDH85B
Hard Disk 9GB Hard Disk 36GB
(10,000rpm) (10,000rpm)
PG-HDH91B/PGBHDH91B PG-HDH61B/PGBHDH61B
Hard Disk 18GB
(7,200rpm)
PG-HDH87B/PGBHDH87B Power Supply Module
(Redundant Power Supply Unit)
Hard Disk 18GB PGUPU103/PGBUPU103
(10,000rpm)
PG-HDH81B/PGBHDH81B
NOTE A maximum of fourteen Hard Disk Drives can be installed in a PRIMERGY S30.
In a RAID configuration, a physical pack must be comprised
of the same type of Hard disks.
External Devices (Pedestal)
H200B225
MS610ES320
PRIMERGY S30 (PGUDC106)
Only H200
Only H200
58
�External Devices
Ext
erna
lD
evic
es
6 SCSI card SCSI cable
GP5-127/GP5B127 GP5MU823A (3m)
6 RAID card(cache:64MB) SCSI cable
GP5-1441/GP5B1441 GP5S-832 (3m)
6 RAID card(cache:16MB) SCSI cable
GP5-145/GP5B145 GP5S-832 (3m)
GP5-146/GP5B146 Hard disk cabinet
GP5MS623A
6 RAID card(cache:64MB) SCSI cable
GP5-148/GP5B148 GP5S-832 (3m)
Configuration of the inside Hard disk cabinet
Hard Disk Drive-9GB Hard Disk Drive-18GB
(7,200rpm) (10,000rpm)
GP5-HDH9B/GP5BHDH9B GP5-HDH87/GP5BHDH87
Hard Disk Drive-36GB
Hard Disk Drive-9GB (10,000rpm)
(10,000rpm) GP5-HDH63/GP5BHDH63
GP5-HDH9A/GP5BHDH9A
Hard Disk Drive-18GB
(7,200rpm) Power Supply Unit
GP5-HDH88/GP5BHDH88 GP5URIPU1/GP5BUR1PU1
NOTE A maximum of eight Hard Disk Drives can be installed in a Storage System.
In a RAID configuration, a physical pack must be comprised
of the same type of Hard disks.
MS610ES320
Hard Disk Cabinet (GP5MS623A)
59
�External Devices
External
Devices
6
RAID Card (cache:64MB) SCSI Cable
GP5-150/GP5B150 PG-CBLS004(2m)/005(5m)/006(10m)
6 PRIMERGY S30
RAID Card (cache:64MB) SCSI Cable PGUR1DC6
GP5-1501/GP5B1501 PG-CBLS004(2m)/005(5m)/006(10m)
6
RAID Controller (cache:64MB) SCSI Cable
PG-142B/PGB142B PG-CBLS004(2m)/005(5m)/006(10m)
6
RAID Controller (cache:64MB) SCSI Cable
PG-142C/PGB142C PG-CBLS004(2m)/005(5m)/006(10m)
6
RAID Controller (cache:64MB) SCSI Cable
PG-143B/PGB143B PG-CBLS004(2m)/005(5m)/006(10m)
6
RAID Controller (cache:128MB) SCSI Cable
PG-144B/PGB144B PG-CBLS004(2m)/005(5m)
Inside of PRIMERGY S30
Hard Disk 9GB Hard Disk 18GB
(7,200rpm) (15,000rpm)
PG-HDH97B/PGBHDH97B PG-HDH85B/PGBHDH85B
Hard Disk 9GB Hard Disk 36GB
(10,000rpm) (10,000rpm)
PG-HDH91B/PGBHDH91B PG-HDH61B/PGBHDH61B
Hard Disk 18GB
(7,200rpm)
PG-HDH87B/PGBHDH87B Power Supply Module
(Redundant Power Supply Unit)
Hard Disk 18GB PGUPU103/PGBUPU103
(10,000rpm)
PG-HDH81B/PGBHDH81B NOTE A maximum of fourteen Hard Disk Drives can be installed in a PRIMERGY S30.
In a RAID configuration, a physical pack must be comprised
of the same type of Hard disks.
Restriction : In case of connection withPG142B/C, up to 13HDD can be mounted in a S30
(The restriction will be eliminated later)
MS610ES320TS225
PRIMERGY S30 (PGUR1DC6)
N800N400H200B225
External Devices (Rack)
Except TS225
Except B225
N400/H200
60
�External Devices
Ext
erna
lD
evic
es
6
SCSI card SCSI Cable
GP5-127/GP5B127 GP5MU823A(3m)/GP5S-833(5m)/834(10m)
6 Storage System
RAID card (cache:64MB) SCSI Cable GP5UR1DC5
GP5-1441/GP5B1441 GP5S-832(3m)/835(5m)/836(10m)
6
RAID card (cache:16MB) SCSI Cable
GP5-145/GP5B145 GP5S-832(3m)/835(5m)/836(10m)
GP5-146/GP5B146
6
RAID card (cache:64MB) SCSI Cable
GP5-148/GP5B148 GP5S-832(3m)/835(5m)/836(10m)
Inside of Storage SystemHard Disk Drive-9GB Hard Disk Drive-18GB
(7,200rpm) (10,000rpm)
GP5-HDH9B/GP5BHDH9B GP5-HDH87/GP5BHDH87
Hard Disk Drive-36GB
Hard Disk Drive-9GB (10,000rpm)
(10,000rpm) GP5-HDH63/GP5BHDH63
GP5-HDH9A/GP5BHDH9A
Hard Disk Drive-18GB
(7,200rpm) Power Supply Unit
GP5-HDH88/GP5BHDH88 GP5URIPU1/GP5BUR1PU1
NOTE A maximum of eight Hard Disk Drives can be installed in a Storage System.
In a RAID configuration, a physical pack must be comprised
of the same type of Hard disks.
MS610ES320TS225
Except TS225
Storage System (GP5UR1DC5)
Except TS225
Except TS225
61
�External Devices
External
Devices
40U Rack 40U Rack & Rack Coupling Kit
GP5-R1RC6 GP5-R1RC7
36U Rack 36U Rack & Rack Coupling Kit
PG-R3RC1 PG-R3RC2
CPU or DISK node
24U Rack 24U Rack & Rack Coupling Kit
GP5-R2RC3 GP5-R2RC4
24U Rack 24U Rack & Rack Coupling Kit
PG-R4RC1 PG-R4RC2
Quake Proof Stabilizer: PG-R3ST1(For PG-R3RCx/PG-R4RCx)Quake Proof Stabilizer: PG-R1ST1(For GP5-R1RCx/GP5-R2RCx)
Cable Holder : GP5-R1CH1(Only TS225/125)
Power Distribution Unit : GP5UPDU1 (Only TS225/125)
Component Shelf
GP5-R1TB7
Keyboard/Monitor Shelf Kit
GP5-R1TB6
Keyboard/Monitor Cable Keyboard/Monitor Enhanced Switch Flat Display
GP5-418(5.0m) GP5-SB102 GP5UR1DP11
Keyboard/Monitor Cable
GP5-414(1.8m)
Keyboard/Monitor Cable Keyboard/Monitor Enhanced Switch Enhanced Keyboard
GP5-411 (3.0m) GP5-SB101 GP5-R1KB2
Up to eight servers can be connected to one GP5-SB102, and up to
64 servers can be connected with nine GP5-SB102 in cascade connection
(Keyboard Monitor Cable: GP5-414 is required)
* In case of Cascade connection, AC adapter is required.
GP5-SB102 GP5-SB102
GP5-414
Rackmount
Rack and Rack Options
(Up to 8 servers connection)
(Up to 4 servers connection)
62
�RackmountRa
ckm
ount
Hardware List
IA64 Rack Optimized Server Value Pedestal Server Storage
N4000 N800 N400 TS225 TS125 MS610 H200 ES320 B225 B125 Storage Subsysetm Backup
Product ID Description
PG
TN
46A
T1R
PG
TN
46A
TR
A
PG
TN
8BH
2R3
PG
TN
8BG
2R3
PG
TN
4AH
1R2
PG
TN
4AG
1R2
GP
5T2T
CLR
GP
5T2T
CE
R
GP
5T1T
CLR
GP
5T1T
CE
R
GP
5T6C
H1A
GP
5T6C
G1A
PG
TH
2AL1
A2
PG
TH
2AE
1A2
GP
5T3D
L1A
GP
5T3D
E1A
PG
TC
2AL1
A
PG
TC
2AE
1A
PG
TC
1AE
1A
PG
TC
1AM
1A
PG
UR
1DC
6
PG
UD
C10
6
GP
5UR
1DC
5
GP
5MS
623A
PG
UR
1BC
3
GP
5UR
1BC
2
PG-FG10T Itanium 800MHz/16KB + 96KB+4MB cache (For N4000) � �
GP5-FG20HT Pentium lll Xeon 700MHz/32KB + 2MB cache (For N800) �GP5BFG20HT
[CTO option]
GP5-FG20GT Pentium lll Xeon 700MHz/32KB + 1MB cache (For N800) �GP5BFG20GT
[CTO option]
PG-FG10H Pentiumlll Xeon(700MHz)/32KB+2MBcachex1 (For N400) �PGBFG10H
[CTO option]
PG-FG10G Pentiumlll Xeon(700MHz)/32KB+1MBcachex1 (For N400) �PGBFG10G
[CTO option]
GP5-FG22L Pentium III 1BGHz/32KB + 256KB cache (For TS225) �GP5BFG22L
[CTO option]
GP5-FG22E Pentium III 933MHz/32KB + 256KB cache (For TS225) �GP5BFG22E
[CTO option]
GP5-FG20H Pentium lll Xeon 700MHz/32KB + 2MB cache (For MS610) �GP5BFG20H
[CTO option]
GP5-FG20G Pentium lll Xeon 700MHz/32KB + 1MB cache (For MS610) �GP5BFG20G
[CTO option]
PG-FG10L Pentiumlll Xeon(1GHz)/32KB+256KBcachex1 (For H200) �PGBFG10L
[CTO option]
PG-FG10E Pentiumlll Xeon(933MHz)/32KB+256KBcachex1 (For H200) �PGBFG10E
[CTO option]
GP5-FG21L Pentium III 1BGHz/32KB + 256KB cache (For ES320)) �GP5BFG21L
[CTO option]
GP5-FG21E Pentium III 933MHz/32KB + 256KB cache (For ES320) �GP5BFG21E
[CTO option]
PG-FG11L Pentium III 1BGHz/32KB + 256KB cache (For B225) �PGBFG11L
[CTO option]
PG-FG11E Pentium III 933MHz/32KB + 256KB cache (For B225) �PGBFG11E
[CTO option]
PG-RM4F 4GB SDRAM-DIMM Buffered CL/2 100MHz (1GBx4) � �
PG-RM1F 1GB SDRAM-DIMM Buffered CL/2 100MHz (256MBx4) � �
GP5-RM2J 2GB SDRAM-DIMM 100MHz (1GBx2) � �GP5BRM2J
[CTO option]
GP5-RM1J 1GB SDRAM-DIMM 100MHz (512MBx2) � �GP5BRM1J
[CTO option]
GP5-RM51J 512MB SDRAM-DIMM 100MHz (256MBx2) � �GP5BRM51J
[CTO option]
PG-RM4B 4GB SDRAM-DIMM Buffered CL/2 100MHz (1GBx4) � �PGBRM4B
[CTO option]
PG-RM2B 2GB SDRAM-DIMM Buffered CL/2 100MHz (512MBx4) � �PGBRM2B
[CTO option]
PG-RM1B 1GB SDRAM-DIMM Buffered CL/2 100MHz (256MBx4) � �PGBRM1B
[CTO option]
PG-RM51B 512MB SDRAM-DIMM Buffered CL/2 100MHz (128MBx4) � �PGBRM51B
[CTO option]
PG-RM25B 256MB SDRAM-DIMM Buffered CL/2 100MHz (64MBx4) � �PGBRM25B
[CTO option]
GP5-RM1M 1GB SDRAM-DIMM Buffered CL/3 133MHz (1GBx1) � � � � � �GP5BRM1M
[CTO option]
GP5-RM51M 512MB SDRAM-DIMM Buffered CL/3 133MHz (512MBx1) � � � � � �GP5BRM51M
[CTO option]
GP5-RM25M 256MB SDRAM-DIMM Buffered CL/3 133MHz (256MBx1) � � � � � �GP5BRM25M
[CTO option]
63
�Hardware List
Hardw
areList
Hardware List
IA64 Rack Optimized Server Value Pedestal Server Storage
N4000 N800 N400 TS225 TS125 MS610 H200 ES320 B225 B125 Storage Subsysetm Backup
Product ID Description
PG
TN
46A
T1R
PG
TN
46A
TR
A
PG
TN
8BH
2R3
PG
TN
8BG
2R3
PG
TN
4AH
1R2
PG
TN
4AG
1R2
GP
5T2T
CLR
GP
5T2T
CE
R
GP
5T1T
CLR
GP
5T1T
CE
R
GP
5T6C
H1A
GP
5T6C
G1A
PG
TH
2AL1
A2
PG
TH
2AE
1A2
GP
5T3D
L1A
GP
5T3D
E1A
PG
TC
2AL1
A
PG
TC
2AE
1A
PG
TC
1AE
1A
PG
TC
1AM
1A
PG
UR
1DC
6
PG
UD
C10
6
GP
5UR
1DC
5
GP
5MS
623A
PG
UR
1BC
3
GP
5UR
1BC
2
GP5-RM12M 128MB SDRAM-DIMM Buffered CL/3 133MHz (128MBx1) � � � � � �GP5BRM12M
[CTO option]
GP5-RM4N 4GB SDRAM-DIMM Buffered CL/2 100MHz (1GBx4) � �GP5BRM4N
[CTO option]
GP5-RM2N 2GB SDRAM-DIMM Buffered CL/2 100MHz (512MBx4) � �GP5BRM2N
[CTO option]
GP5-RM1N 1GB SDRAM-DIMM Buffered CL/2 100MHz (256MBx4) � �GP5BRM1N
[CTO option]
GP5-RM51N 512MB SDRAM-DIMM Buffered CL/2 100MHz (128MBx4) � �GP5BRM51N
[CTO option]
GP5-RM25N 256MB SDRAM-DIMM Buffered CL/2 100MHz (64MBx4) � �GP5BRM25N
[CTO option]
PG-RM2A 2GB SDRAM-DIMM Buffered CL/2 133MHz (1GBx2) � �PGBRM2A
[CTO option]
PG-RM1A 1GB SDRAM-DIMM Buffered CL/2 133MHz (512MBx2) � �PGBRM1A
[CTO option]
PG-RM51A 512MB SDRAM-DIMM Buffered CL/2 133MHz (256MBx2) � �PGBRM51A
[CTO option]
PG-RM25A 256MB SDRAM-DIMM Buffered CL/2 133MHz (256MBx2) � �PGBRM25A
[CTO option]
PG-RM1D 1GB SDRAM-DIMM Buffered CL/2 133MHz (512MBx2) � �PGBRM1D
[CTO option]
PG-RM51D 512MB SDRAM-DIMM Buffered CL/2 133MHz (256MBx2) � �PGBRM51D
[CTO option]
PG-RM25D 256MB SDRAM-DIMM Buffered CL/2 133MHz (128MBx2) � �PGBRM25D
[CTO option]
PG-RM51E 512MB SDRAM-DIMM Buffered CL/2 133MHz (256MBx2) � �PGBRM51E
[CTO option]
PG-RM25E 256MB SDRAM-DIMM Buffered CL/2 133MHz (128MBx2) � �PGBRM25E
[CTO option]
PG-RM12E 128MB SDRAM-DIMM Buffered CL/2 133MHz (64MBx2) � �PGBRM12E
[CTO option]
PGBRU4C Standard Memory conversion 1GB to 4GB � �[CTO option]
PGBRU2C Standard Memory conversion 1GB to 2GB � �[CTO option]
PGBRU4B Standard Memory conversion 512MB to 4GB � �[CTO option]
PGBRU2B Standard Memory conversion 512MB to 2GB � �[CTO option]
PGBRU1B Standard Memory conversion 512MB to 1GB � �[CTO option]
GP5BRU1GH Standard Memory conversion 128MB to 1GB � � � �[CTO option]
GP5BRU51L Standard Memory conversion 128MB to 512MB � � � �[CTO option]
GP5BRU25H Standard Memory conversion 128MB to 256MB � � � �[CTO option]
GP5BRU4GB Standard Memory conversion 512MB to 4GB � �[CTO option]
GP5BRU2GD Standard Memory conversion 512MB to 2GB � �[CTO option]
GP5BRU1GJ Standard Memory conversion 512MB to 1GB � �[CTO option]
PGBRU2A Standard Memory conversion 256MB to 2GB � �[CTO option]
PGBRU1A Standard Memory conversion 256MB to 1GB � �[CTO option]
PGBRU51A Standard Memory conversion 256MB to 512MB � �[CTO option]
GP5BRU1GE Standard Memory conversion 256MB to 1GB � �[CTO option]
GP5BRU51J Standard Memory conversion 256MB to 512MB � �[CTO option]
PGBRU1D Standard Memory conversion 256MB to 1GB � �[CTO option]
PGBRU51D Standard Memory conversion 256MB to 512MB � �[CTO option]
PGBRU51E Standard Memory conversion 128MB to 512MB � �[CTO option]
64
�Hardware List
Har
dwar
eLi
st
Hardware List
IA64 Rack Optimized Server Value Pedestal Server Storage
N4000 N800 N400 TS225 TS125 MS610 H200 ES320 B225 B125 Storage Subsysetm Backup
Product ID Description
PG
TN
46A
T1R
PG
TN
46A
TR
A
PG
TN
8BH
2R3
PG
TN
8BG
2R3
PG
TN
4AH
1R2
PG
TN
4AG
1R2
GP
5T2T
CLR
GP
5T2T
CE
R
GP
5T1T
CLR
GP
5T1T
CE
R
GP
5T6C
H1A
GP
5T6C
G1A
PG
TH
2AL1
A2
PG
TH
2AE
1A2
GP
5T3D
L1A
GP
5T3D
E1A
PG
TC
2AL1
A
PG
TC
2AE
1A
PG
TC
1AE
1A
PG
TC
1AM
1A
PG
UR
1DC
6
PG
UD
C10
6
GP
5UR
1DC
5
GP
5MS
623A
PG
UR
1BC
3
GP
5UR
1BC
2
PGBRU25E Standard Memory conversion 128MB to 256MB � �[CTO option]
PG-RB104 Memory Expansion Board for N4000 - 32GB Max � �Required to fit more than 32 DIMMs
PG-RB103 Memory Expansion Board for N800 - 16GB Max � �PGBRB103 Required to fit more than 16 DIMMs
[CTO option]
GP5-FN101 Cooling Kit for MS610: High speed FANx2, Air Ductx1, Required when � �more than three 4GB Memory (GP5-RM4N/GP5BRM4N/GP5BRU4GB)
are mounted.
PG-HDH61D 36.4GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � �
PG-HDH61B 36.4GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � � � � � �PGBHDH61B
[CTO option]
PG-HDH85B 18.2GB 1" Ultra160 SCSI 15000rpm SCA2 80pin Hotplug SMART � � � � � �PGBHDH85B
[CTO option]
PG-HDH81B 18.2GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � � � � � �PGBHDH81B
[CTO option]
PG-HDH91B 9.1GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � � � � � �PGBHDH91B
[CTO option]
PG-HDH87B 18.2GB 1" Ultra160 SCSI 7200rpm SCA2 80pin Hotplug SMART � � � �PGBHDH87B
[CTO option]
PG-HDH97B 9.1GB 1" Ultra160 SCSI 7200rpm SCA2 80pin Hotplug SMART � �PGBHDH97B
[CTO option]
PG-HDH61A 36.4GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � �PGBHDH61A
[CTO option]
PG-HDH85A 18.2GB 1" Ultra160 SCSI 15000rpm SCA2 80pin Hotplug SMART � �PGBHDH81A
[CTO option]
PG-HDH81A 18.2GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � �PGBHDH81A
[CTO option]
PG-HDH91A 9.1GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � �PGBHDH91A
[CTO option]
PG-HDH87A 18.2GB 1" Ultra160 SCSI 7200rpm SCA2 80pin Hotplug SMART � �PGBHDH87A
[CTO option]
PG-HDH97A 9.1GB 1" Ultra160 SCSI 7200rpm SCA2 80pin Hotplug SMART � �PGBHDH97A
[CTO option]
PG-HDH61C 36.4GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � �PGBHDH61C
[CTO option]
PG-HDH81C 18.2GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � �PGBHDH81C
[CTO option]
PG-HDH91C 9.1GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � �PGBHDH91C
[CTO option]
PG-HD6G1C 36.4GB 1" Ultra160 SCSI 10000rpm 68pin Non Hotplug � � � �PGBHD6G1C
[CTO option]
PG-HD8G1C 18.2GB 1" Ultra160 SCSI 10000rpm 68pin Non Hotplug � � � �PGBHD8G1C
[CTO option]
PG-HD9G1C 9.1GB 1" Ultra160 SCSI 10000rpm 68pin Non Hotplug � � � �PGBHD9G1C
[CTO option]
PG-HD4E7C 40.9GB 1" EIDE(ATA100) 7200rpm � �PGBHD4E7C
[CTO option]
PG-HD4E5C 40.9GB 1" EIDE(ATA100) 5400rpm � �PGBHD4E5C
[CTO option]
GP5-HDH63 36.4GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � � � � � � � �GP5BHDH63
[CTO option]
GP5-HDH8B 18.2GB 1" Ultra160 SCSI 15000rpm SCA2 80pin Hotplug SMART � � � � � � � �GP5BHDH8B
[CTO option]
GP5-HDH87 18.2GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � � � �GP5BHDH87
[CTO option]
65
�Hardware List
Hardw
areList
Hardware List
IA64 Rack Optimized Server Value Pedestal Server Storage
N4000 N800 N400 TS225 TS125 MS610 H200 ES320 B225 B125 Storage Subsysetm Backup
Product ID Description
PG
TN
46A
T1R
PG
TN
46A
TR
A
PG
TN
8BH
2R3
PG
TN
8BG
2R3
PG
TN
4AH
1R2
PG
TN
4AG
1R2
GP
5T2T
CLR
GP
5T2T
CE
R
GP
5T1T
CLR
GP
5T1T
CE
R
GP
5T6C
H1A
GP
5T6C
G1A
PG
TH
2AL1
A2
PG
TH
2AE
1A2
GP
5T3D
L1A
GP
5T3D
E1A
PG
TC
2AL1
A
PG
TC
2AE
1A
PG
TC
1AE
1A
PG
TC
1AM
1A
PG
UR
1DC
6
PG
UD
C10
6
GP
5UR
1DC
5
GP
5MS
623A
PG
UR
1BC
3
GP
5UR
1BC
2
GP5-HDH9A 9.1GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � � � �GP5BHDH9A
[CTO option]
GP5-HDH8A 18.2GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � � � �GP5BHDH8A
[CTO option]
GP5-HDH9D 9.1GB 1" Ultra160 SCSI 10000rpm SCA2 80pin Hotplug SMART � � � �GP5BHDH9D
[CTO option]
GP5-HDH88 18.2GB 1" Ultra160 SCSI 7200rpm SCA2 80pin Hotplug SMART � � � �GP5BHDH88
[CTO option]
GP5-HDH9B 9.1GB 1" Ultra160 SCSI 7200rpm SCA2 80pin Hotplug SMART � � � �GP5BHDH9B
[CTO option]
GP5-HDH89 18.2GB 1" Ultra160 SCSI 7200rpm SCA2 80pin Hotplug SMART � �GP5BHDH89
[CTO option]
GP5-HDH9C 9.1GB 1" Ultra160 SCSI 7200rpm SCA2 80pin Hotplug SMART � �GP5BHDH9C
[CTO option]
GP5-HD6G1 36.4GB 1" Ultra160 SCSI 10000rpm 68pin Non Hotplug � �GP5BHD6G1
[CTO option]
GP5-HD8G2 18.2GB 1" Ultra160 SCSI 10000rpm 68pin Non Hotplug � �GP5BHD8G2
[CTO option]
GP5-HD9G4 9.1GB 1" Ultra160 SCSI 10000rpm 68pin Non Hotplug � �GP5BHD9G4
[CTO option]
GP5-HD4E71 40.9GB 1" EIDE(ATA100) 7200rpm � �GP5BHD4E71
[CTO option]
GP5-HD4E51 40.9GB 1" EIDE(ATA100) 5400rpm � �GP5BHD4E51
[CTO option]
GP5BHU6GD TS125 Base HDD conversion - 40GB EIDE to 36.4GB SCSI [CTO Option] � �[CTO option] (1"height/Ultra160 SCSI/10,000rpm/68pin/Non-Hotplug/SMART)
GP5BHU8G11 TS125 Base HDD conversion - 40GB EIDE to 18.2GB SCSI [CTO Option] � �[CTO option] (1"height/Ultra160 SCSI/10,000rpm/68pin/Non-Hotplug/SMART)
GP5BHU9GV TS125 Base HDD conversion - 40GB EIDE to 9.1GB SCSI [CTO Option] � �[CTO option] (1"height/Ultra160 SCSI/10,000rpm/68pin/Non-Hotplug/SMART)
GP5BHU4G3 TS125 Base HDD conversion � �[CTO option] - 40GB EIDE 5400rpm to 40GB EIDE 7200rpm [CTO Option]
PGBBU103 N400 Base Backplane Conversion � �[CTO option] 4xHDD to 2xHDD + 1 x Tape BU [CTO Option]
PGBBU102 N400 Base Backplane Conversion � �[CTO option] 1ch x 4HDD to 2ch x 2HDD [CTO Option]
PGBBU101 H200 Base Backplane Conversion � �[CTO option] 1ch x 8HDD to 2ch x 4HDD [CTO Option]
GP5BBU1 MS610 HDD Cage conversion - 8x1.6"/1" to 12 x 1" [CTO Option] � �[CTO option]
PGBBU104 B225 Base Backplane Conversion Non Hotplug to Hotplug [CTO Option] � �[CTO option]
PGUR1DC6 PRIMERGY S30 Disk Subsystem Rackmount (3U) Node 14xHDD (2ch.) bays � � � � � � R R R R R R R R
Redundant & Hotplug FAN (Std.)/PSU (Opt.)
<Available HDD>
PG-HDH61B/85B/81B/91B/87B/97B
Only for Array configuration, CTO is available
PGUDC106 PRIMERGY S30 Disk Subsystem Pedestal Node 14 x HDD (2ch.) bays P P P P P P P P
Redundant & Hotplug FAN (Std.)/PSU (Opt.)
<Available HDD>
PG-HDH61B/85B/81B/91B/87B/97B
Only for Array configuration, CTO is available
GP5UR1DC5 Disk Subsystem Rackmount (3U) Node 8 x HDD (1/2ch.) bays � � R R R R
Redundant & Hotplug FAN (Std.)/PSU (Opt.)
<Available HDD>
GP5-HDH63/8B/87/9A/88/9B
CTO is available
GP5MS623A Disk Subsystem Pedestal Node 8 x HDD (1/2ch.) bays P P P P
Redundant & Hotplug FAN (Std.)/PSU (Opt.)
<Available HDD>
GP5-HDH63/8B/87/9A/88/9B
CTO is available
PG-DT401 Internal DAT unit (DDS4: 20GB-40GB) � � � � � � � � � � �PGBDT401
[CTO option]
PG-DT301 Internal DAT unit (DDS3: 12-24GB) � � � � � � � � �PGBDT301
[CTO option]
66
�Hardware List
Har
dwar
eLi
st
Hardware List
IA64 Rack Optimized Server Value Pedestal Server Storage
N4000 N800 N400 TS225 TS125 MS610 H200 ES320 B225 B125 Storage Subsysetm Backup
Product ID Description
PG
TN
46A
T1R
PG
TN
46A
TR
A
PG
TN
8BH
2R3
PG
TN
8BG
2R3
PG
TN
4AH
1R2
PG
TN
4AG
1R2
GP
5T2T
CLR
GP
5T2T
CE
R
GP
5T1T
CLR
GP
5T1T
CE
R
GP
5T6C
H1A
GP
5T6C
G1A
PG
TH
2AL1
A2
PG
TH
2AE
1A2
GP
5T3D
L1A
GP
5T3D
E1A
PG
TC
2AL1
A
PG
TC
2AE
1A
PG
TC
1AE
1A
PG
TC
1AM
1A
PG
UR
1DC
6
PG
UD
C10
6
GP
5UR
1DC
5
GP
5MS
623A
PG
UR
1BC
3
GP
5UR
1BC
2
PG-DTA102 Internal DAT autoloader (DDS4: 20GB-40GB) 6cassetes � � �PGBDTA102
[CTO option]
PG-DTA101 Internal DAT autoloader (DDS3: 12GB-24GB) 6cassetes � � �PGBDTA101
[CTO option]
PG-DL401 Internal DLT unit (DLT8000: 40-80GB) � � � � �PGBDL401
[CTO option]
PG-DL351 Internal DLT unit (DLT7000: 35-70GB) � � �PGBDL351
[CTO option]
PG-DL201 Internal DLT unit (DLT4000: 20GB-40GB) � � �PGBDL201
[CTO option]
PG-LT101 Internal LTO unit (LTO: 100-200GB) � � �PGBLT101
[CTO option]
PG-SL101 Internal Tape unit (SLR100: 50-100GB) � � � � � � � � � � � � �PGBSL101
[CTO option]
PG-SL601 Internal Tape unit (SLR60: 30-60GB) � � � � � � � � � � � � �PGBSL601
[CTO option]
PG-ML301 Internal Tape unit (SLR50: 25-50GB) � � � � �PGBML301
[CTO option]
GP5-DT401 Internal DAT unit (DDS4:20GB-40GB) � � � � �GP5BDT401
[CTO option]
GP5UDT301 Internal DAT unit (DDS3:12-24GB) � � � � �GP5BDT301
[CTO option]
GP5-DTA102 Internal DAT autoloader (DDS4: 20GB-40GB) 6cassetes � � � � �GP5BDTA102
[CTO option]
GP5UDTA101 Internal DAT autoloader (DDS3: 12GB-24GB) 6cassetes � � � � �GP5BDTA101
[CTO option]
GP5USL501 Internal SLR unit (SLR-5: 4-8GB) � � � � �GP5BSL501
[CTO option]
GP5-DL351 Internal DLT unit(DLT7000: 35-70GB) Two 5"bays are occupied � � � � �GP5BDL351
[CTO option]
GP5UDL201 Internal DLT unit (DLT4000: 20GB-40GB) Two 5" bays are occupied � � � � �GP5BDL201
[CTO option]
GP5-ML301 Internal MLR unit (SLR50: 25-50GB) � � � � �GP5BML301
[CTO option]
GP5-BC2 Metal fittings for mounting internal DLT4000 � �GP5BBC2
[CTO option]
GP5-CD313 24x CD-ROM option for TS225/TS125 � � � �GP5BCD313
[CTO option]
GP5UR1BC2 4 x 5" bay Tape Backup Rackmount (3U) Node � � � �Up to four Tape units can be mounted
Occupy two bays : GP5UDL351/GP5UDL201/GP5-DTA101/GP5-DTA102
Occupy one bay: GP5-ML301/GP5-DT401/GP5UDT301/GP5USL501
Power management (RCI), Redundant PSU Opt.
[Base unit which supports CTO tape drive options]
PGUR1BC3 PRIMERGY S10 4 x 5" bay Tape Backup Rackmount (3U) node � � � � � � R R R R
Up to four Tape units can be mounted
<Available Backup devices>
Occupy two bays : PG-DL201/PG-DL351/PG-DL401/PG-DTA101/PG-DTA102
Occupy one bay: PG-SL101/PG-SL601/PG-ML301/PG-DT401/PG-DT301
*When connecting to N4000, PG-DL401 and PG-DT401 can be mounted in S10
[Base unit which supports CTO tape drive options]
PG-PU104 Redundant PSU (800W) <N4000> � �
PGUPU103 Redundant PSU (500W) <S30> � �PGBUPU103
[CTO option]
PG-PU102 Redundant PSU (500W) <N400/S10> � � �PGBPU102
[CTO option]
67
�Hardware List
Hardw
areList
Hardware List
IA64 Rack Optimized Server Value Pedestal Server Storage
N4000 N800 N400 TS225 TS125 MS610 H200 ES320 B225 B125 Storage Subsysetm Backup
Product ID Description
PG
TN
46A
T1R
PG
TN
46A
TR
A
PG
TN
8BH
2R3
PG
TN
8BG
2R3
PG
TN
4AH
1R2
PG
TN
4AG
1R2
GP
5T2T
CLR
GP
5T2T
CE
R
GP
5T1T
CLR
GP
5T1T
CE
R
GP
5T6C
H1A
GP
5T6C
G1A
PG
TH
2AL1
A2
PG
TH
2AE
1A2
GP
5T3D
L1A
GP
5T3D
E1A
PG
TC
2AL1
A
PG
TC
2AE
1A
PG
TC
1AE
1A
PG
TC
1AM
1A
PG
UR
1DC
6
PG
UD
C10
6
GP
5UR
1DC
5
GP
5MS
623A
PG
UR
1BC
3
GP
5UR
1BC
2
PG-PU101 Redundant PSU (400W) <H200> � �PGBPU101
[CTO option]
GP5UPU161 Redundant PSU (350W) <MS610> � �GP5BUPU161
[CTO option]
GP5UPU151 Redundant PSU (305W) <ES320/Backup Cabinet> � � �GP5BUPU151
[CTO option]
GP5UR1PU1 Redundant PSU (350W) <Storage System/Hard Disk Cabinet> � �GP5BUR1PU1
[CTO option]
GP5-R1RC6 19'' 40U Rack , Front door, Rear door, Side panel, Stabilizer � � � � � � � � � � R R R R R R R R � � � �Blank panel are attached. (WxDxH)mm:600x900x2000
GP5-R1RC7 19''40U Rack + Connection metal fittings Front door, Rear door, � � � � � � � � � � R R R R R R R R � � � �Concatenation frame, Blank panel are attached.
GP5-R2RC3 19'' 24U Rack , Front door, Rear door, Side panel, Stabilizer � � � � � � � � � � R R R R R R R R � � � �Blank panel are attached. (WxDxH)mm:600x900x1200
GP5-R2RC4 19'' 24U Rack + Connection metal fittings Front door, Rear door, � � � � � � � � � � R R R R R R R R � � � �Concatenation frame, Blank panel are attached.
PG-R3RC1 19'' 36U Rack , Front door, Rear door, Side panel, Stabilizer � � � � � � � � � � R R R R R R R R � � � �Blank panel are attached. (WxDxH)mm:700x950x1800
PG-R3RC2 19" 36U Rack and Connection metal fittings, � � � � � � � � � � R R R R R R R R � � � �
PG-R4RC1 19'' 24U Rack , Front door, Rear door, Side panel, Stabilizer � � � � � � � � � � R R R R R R R R � � � �Blank panel are attached. (WxDxH)mm:700x950x1267
PG-R4RC2 19" 24U Rack and Connection metal fittings, � � � � � � � � � � R R R R R R R R � � � �
PG-R3ST1 Quake proof stabilizer for Rack (PG-R3RCx/PG-R4RCx) � � � � � � � � � � R R R R R R R R � � � �
PG-R1ST1 Quake proof stabilizer for Rack (GP5-R1RCx/GP5-R2RCx) � � � � � � � � � � R R R R R R R R � � � �
GP5-R1TB7 Shelf to fit peripheral device into 40U Rack, Table size:400(W)x500(D) � � � � � � � � � � R R R R R R R R � � � �
GP5-R1TB6 Used to store display unit (CRT), a keyboard (KB), and a mouse on a rack. � � � � � � � � � � R R R R R R R R � � � �
GP5-SB101 Switch enables sharing of a set of CRT,keyboard,and mouse by two � � � � � � � � � � � � � � � � � � � �or more servers (up to four servers).
GP5-SB102 Switch enables sharing of a set of CRT,keyboard,and mouse by two � � � � � � � � � � R R R R R R R R
or more servers (up to eight servers). Shared up to 64 servers in
cascade connection.* AC adapter is required for cascade connection
(Procured locally)
GP5-R1RK5 Rackmounting Kit <For Storage System> �Rail for mounting Fujitsu 19"Rack as below;
40U: GP5-R1RC6/GP5-R1RC7, 36U: PG-R3RC1/PG-R3CN1
24U: GP5-R2RC3/GP5-R2RC4/PG-R4RC1/PG-R4RC2
GP5-R1RK8 Rackmounting Kit <For Backup Cabinet> �Rail for mounting Fujitsu 19"Rack as below;
40U: GP5-R1RC6/GP5-R1RC7, 36U: PG-R3RC1/PG-R3CN1
24U: GP5-R2RC3/GP5-R2RC4/PG-R4RC1/PG-R4RC2
PGBR1CK3 H200 Base Chassis conversion option Pedesal to Rackmount [CTO Option] � �[CTO option]
PGBR1CK4 MS610 Base Chassis conversion option Pedesal to Rackmount [CTO Option] � �[CTO option]
PGBR1CK2 ES320 Base Chassis conversion option Pedesal to Rackmount [CTO Option] � �[CTO option]
PGBR1CK1 B225 Base Chassis conversion option Pedesal to Rackmount [CTO Option] � �[CTO option]
GP5-418 For connection with switch (For connection GP5-SB102) (5.0m) � � � � � � � � � � R R R R R R R R
GP5-414 For cascade connection between GP5-SB102 (1.8m) � � � � � � � � � � R R R R R R R R
GP5-411 CRT/KB cable for connection Server with GP5-SB101, � � � � � � � � � � � � � � � � � � � �CRT cablex1,KB/Mouse cablex1 is attached
GP5-R1KB2 87Key keyboard for Rackmountable type � � � � � � � � � � � � � � � � � � � �GP5UPDU1 Power Distribution Unit (8sockets), Power cables are required � � � �GP5-R1CH1 Rackmount cabling holder � � � �GP5UR1DP11 Rackmountable LCD display with Keyboard, 2U height � � � � � � � � � � R R R R R R R R
GP5-123 SCSI Controller Ultrawide HVD 1channel � �SMART HDD not supported
Up to 40MB/s syncronous transfer rate
- 68pin connector for external UW SCSI device
- 68pin connector for internal UW SCSI device
- 50pin connector for internal Narrow SCSI device
* SCSI cable is required.
GP5-127 SCSI Controller Ultra2wide LVD 1 channel � � � �GP5B127 SMART HDD supported
[CTO option] Up to 80MB/s syncronous transfer rate
- 68 pin connector for external U2W SCSI device
- 68/50 pin connector for internal U2W SCSI device
* SCSI Cable is required
68
�Hardware List
Har
dwar
eLi
st
Hardware List
IA64 Rack Optimized Server Value Pedestal Server Storage
N4000 N800 N400 TS225 TS125 MS610 H200 ES320 B225 B125 Storage Subsysetm Backup
Product ID Description
PG
TN
46A
T1R
PG
TN
46A
TR
A
PG
TN
8BH
2R3
PG
TN
8BG
2R3
PG
TN
4AH
1R2
PG
TN
4AG
1R2
GP
5T2T
CLR
GP
5T2T
CE
R
GP
5T1T
CLR
GP
5T1T
CE
R
GP
5T6C
H1A
GP
5T6C
G1A
PG
TH
2AL1
A2
PG
TH
2AE
1A2
GP
5T3D
L1A
GP
5T3D
E1A
PG
TC
2AL1
A
PG
TC
2AE
1A
PG
TC
1AE
1A
PG
TC
1AM
1A
PG
UR
1DC
6
PG
UD
C10
6
GP
5UR
1DC
5
GP
5MS
623A
PG
UR
1BC
3
GP
5UR
1BC
2
PG-123 SCSI Controller Ultrawide HVD 1channel � � � � � �PGB123 SMART HDD not supported
[CTO option] Up to 40MB/s syncronous transfer rate
- 68pin connector for external UW SCSI device
- 68pin connector for internal UW SCSI device
- 50pin connector for internal Narrow SCSI device
* SCSI cable is required.
PG-126 SCSI Controller Ultra2wide LVD 1 channel � � � � � �PGB126 SMART HDD supported
[CTO option] Up to 80MB/s synchronous transfer rate
- 68 pin connector for external U2W SCSI device
- 68 pin connector for internal U2W SCSI device
- 68 pin connector for internal UW SE SCSI device
-50 pin connector for internal Narrow SCSI device
*SCSI cable is required
PG-128 SCSI Controller Ultra160 LVD 1 channel � � � �PGB128 <Connector>
[CTO option] - 68-pin connector for external SCSI device (Ultra160)
- 68-pin connector for internal SCSI device (Ultra160)
- 68-pin connector for internal SCSI device (Ultra Wide)
- 50-pin connector for internal SCSI device (Ultra Wide)
*SCSI cable is required
GP5-143 RAID Controller Ultra2 wide LVD 1ch 8MB cache Int. � �GP5B143 RAID level 0,1,5,6(0+1) are supported
[CTO option] For internal array configuration
GP5-1441 RAID Controller Ultra2 wide LVD 3ch 64MB cache, Battery Backup � � � �GP5B1441 RAID level 0,1,5,6(0+1) are supported
[CTO option] For internal/external array configuration
GP5-145 RAID Controller Ultra2 wide LVD 2ch 16MB cache � � � �GP5B145 RAID level 0,1,5,6(0+1) are supported
[CTO option] For internal/external array configuration
GP5-146 RAID Controller Ultra2 wide LVD 2ch 16MB cache, Battery Backup � � � �GP5B146 RAID level 0,1,5,6(0+1) are supported
[CTO option] For internal/external array configuration
GP5-148 RAID Controller Ultra160 LVD 2ch 64MB cache � � � � � �GP5B148 RAID level 0,1,5,6(0+1) are supported
[CTO option] For internal/external array configuration
GP5-150 RAID Controller, Ultra160 2ch 64MB cache � � � � � �GP5B150 RAID level 0,1,5 are supported
[CTO option] For internal/external array configuration
GP5-1501 RAID Controller, Ultra160 2ch 64MB cache, Battery Backup � � � �GP5B1501 RAID level 0,1,5 are supported
[CTO option] For internal/external array configuration
GP5-151 RAID Controller, Ultra160 1ch 32MB cache � � � �GP5B151 RAID level 0,1,5 are supported
[CTO option] For internal array configuration
PG-141B RAID Controller, Ultra160 1ch 32MB cache � � � �PGB141B RAID level 0,1,5 are supported
[CTO option] For internal array configuration
PG-142B RAID Controller, Ultra160 2ch 64MB cache � � � � � � � �PGB142B RAID level 0,1,5 are supported
[CTO option] For internal/external array configuration
PG-142C RAID Controller, Ultra160 2ch 64MB cache, Battery Backup � � � � � � � �PGB142C RAID level 0,1,5 are supported
[CTO option] For internal/external array configuration
PG-143B RAID Controller, Ultra2 Wide 3ch 64MB cache, Battery Backup � � � �PGB143B RAID level 0,1,5, (0+1) are supported
[CTO option] For internal/external array configuration
PG-144B RAID Controller, Ultra160 4ch 128MB cache, Battery Backup � � � � � �PGB144B RAID level 0,1,5, (0+1) are supported
[CTO option] For internal/external array configuration
PGB1U42C1 Convert Standard RAID Controller to PG-142C � �[CTO option]
PG-CBLS001 External SCSI Cable (1.5m) � � � � R R R R
<Connection>
- SCSI Controller and S10/External SCSI devices
PG-CBLS002 External SCSI Cable (5m) � � � � R R R R
<Connection>
- SCSI Controller and S10/External SCSI devices
PG-CBLS003 External SCSI Cable (10m) � � � � R R R R
<Connection>
- SCSI Controller and S10/External SCSI devices
PG-CBLS004 External SCSI Cable (2m) � � � � R R R R R R R R
<Connection>
- RAID Controller and S30
PG-CBLS005 External SCSI Cable (5m) � � � � R R R R R R R R
<Connection>
- RAID Controller and S30
PG-CBLS006 External SCSI Cable (10m) � � � � R R R R R R R R
<Connection>
- RAID Controller and S30
69
�Hardware List
Hardw
areList
Hardware List
IA64 Rack Optimized Server Value Pedestal Server Storage
N4000 N800 N400 TS225 TS125 MS610 H200 ES320 B225 B125 Storage Subsysetm Backup
Product ID Description
PG
TN
46A
T1R
PG
TN
46A
TR
A
PG
TN
8BH
2R3
PG
TN
8BG
2R3
PG
TN
4AH
1R2
PG
TN
4AG
1R2
GP
5T2T
CLR
GP
5T2T
CE
R
GP
5T1T
CLR
GP
5T1T
CE
R
GP
5T6C
H1A
GP
5T6C
G1A
PG
TH
2AL1
A2
PG
TH
2AE
1A2
GP
5T3D
L1A
GP
5T3D
E1A
PG
TC
2AL1
A
PG
TC
2AE
1A
PG
TC
1AE
1A
PG
TC
1AM
1A
PG
UR
1DC
6
PG
UD
C10
6
GP
5UR
1DC
5
GP
5MS
623A
PG
UR
1BC
3
GP
5UR
1BC
2
GP5-189 Gigabit Ethernet Controller 1000BASE-SX PCI64bit � � � � � �GP5B189 *Twisted pair cable (Enhanced category5:1000BASE-T) is required
[CTO option]
GP5-FC101 Fiber Channel Controller, PCI, FC-AL(Arbitrated loop) � � � � � � � �Duplex SC port for external device
Fibre Channel cable is required :
GP5-311/2m, GP5-312/5m, GP5-313/15m
GP5-FC102 Fiber Channel Controller, PCI, FC-AL(Arbitrated loop)/FC Fabric � � � � � �
Duplex SC port for external device
Fibre Channel cable is required :
GP5-311/2m, GP5-312/5m, GP5-313/15m
PG-185 Fast Ethernet Controller 100BASE-TX/10BASE-T PCI 32bit � � � � � � � � � � � �PGB185 Twisted pair cable is required
[CTO option] (category 5:100BASE-TX/category 3:10BASE-T)
PG-183 Gigabit Ethernet 1000BASE-SX PCI 64bit - Fibre cable is required : � � � �PGB183 - GP5-311/2m, GP5-312/5m, GP5-313/15m
[CTO option]
PG-188 Gigabit Ethernet Controller 1000BASE-SX PCI 64bit Fibre cable is required � � � � � � � � � � � �PGB188 : GP5-311/2m, GP5-312/5m, GP5-313/15m
[CTO option]
PG-189 Gigabit Ethernet Controller 1000BASE-SX PCI64bit � � � � � � � � � � � �PGB189 *Twisted pair cable (Enhanced category5:1000BASE-T) is required
[CTO option]
PG-FC102 Fiber Channel Controller, PCI, FC-AL(Arbitrated loop)/FC Fabric � � � � � � � �Duplex SC port for external device
Fibre Channel cable is required :
GP5-311/2m, GP5-312/5m, GP5-313/15m
GP5USM103 Server Monitor Module has its own CPU,LAN,and power supply (AC � � � �GP5BUSM103 adapter: option-procured locally)/External Interface:10BASE-T
[CTO option] RJ45/RS232C D-sub 9pin/AC adapter:16V(DC) * Modem-only
operation is impossible.
PGURSB101 Optional remote server management board (PCI) � � � � � � � � � �CPU, External Interface (10BASE-T/RS232C), External PowerSupply
(AC adapter - Option) are on the board
PG-RSBOP1 Optional Kit for mounting RSB for N400/H200 � � � �ServerView for RSB CD-ROM, Connector, Power Code are included
PG-RSBOP2 Optional Kit for mounting RSB for N800 � �RSB Utility FPD, Connector, Power Code are included
PG-RSBOP3 Optional Kit for mounting RSB for B225 � �RSB Utility FPD, Connector, Power Code are included
PG-RSBOP4 Optional Kit for mounting RSB for B125 � �RSB Utility FPD, Connector, Power Code are included
70
�Hardware List
Har
dwar
eLi
st
Hardware List
IA64 Rack Optimized Server Value Pedestal Server Storage
N4000 N800 N400 TS225 TS125 MS610 H200 ES320 B225 B125 Storage Subsysetm Backup
Product ID Description
PG
TN
46A
T1R
PG
TN
46A
TR
A
PG
TN
8BH
2R3
PG
TN
8BG
2R3
PG
TN
4AH
1R2
PG
TN
4AG
1R2
GP
5T2T
CLR
GP
5T2T
CE
R
GP
5T1T
CLR
GP
5T1T
CE
R
GP
5T6C
H1A
GP
5T6C
G1A
PG
TH
2AL1
A2
PG
TH
2AE
1A2
GP
5T3D
L1A
GP
5T3D
E1A
PG
TC
2AL1
A
PG
TC
2AE
1A
PG
TC
1AE
1A
PG
TC
1AM
1A
PG
UR
1DC
6
PG
UD
C10
6
GP
5UR
1DC
5
GP
5MS
623A
PG
UR
1BC
3
GP
5UR
1BC
2
GP5-189 Gigabit Ethernet Controller 1000BASE-SX PCI64bit � � � � � �GP5B189 *Twisted pair cable (Enhanced category5:1000BASE-T) is required
[CTO option]
GP5-FC101 Fiber Channel Controller, PCI, FC-AL(Arbitrated loop) � � � � � � � �Duplex SC port for external device
Fibre Channel cable is required :
GP5-311/2m, GP5-312/5m, GP5-313/15m
GP5-FC102 Fiber Channel Controller, PCI, FC-AL(Arbitrated loop)/FC Fabric � � � � � �
Duplex SC port for external device
Fibre Channel cable is required :
GP5-311/2m, GP5-312/5m, GP5-313/15m
PG-185 Fast Ethernet Controller 100BASE-TX/10BASE-T PCI 32bit � � � � � � � � � � � �PGB185 Twisted pair cable is required
[CTO option] (category 5:100BASE-TX/category 3:10BASE-T)
PG-183 Gigabit Ethernet 1000BASE-SX PCI 64bit - Fibre cable is required : � � � �PGB183 - GP5-311/2m, GP5-312/5m, GP5-313/15m
[CTO option]
PG-188 Gigabit Ethernet Controller 1000BASE-SX PCI 64bit Fibre cable is required � � � � � � � � � � � �PGB188 : GP5-311/2m, GP5-312/5m, GP5-313/15m
[CTO option]
PG-189 Gigabit Ethernet Controller 1000BASE-SX PCI64bit � � � � � � � � � � � �PGB189 *Twisted pair cable (Enhanced category5:1000BASE-T) is required
[CTO option]
PG-FC102 Fiber Channel Controller, PCI, FC-AL(Arbitrated loop)/FC Fabric � � � � � � � �Duplex SC port for external device
Fibre Channel cable is required :
GP5-311/2m, GP5-312/5m, GP5-313/15m
GP5USM103 Server Monitor Module has its own CPU,LAN,and power supply (AC � � � �GP5BUSM103 adapter: option-procured locally)/External Interface:10BASE-T
[CTO option] RJ45/RS232C D-sub 9pin/AC adapter:16V(DC) * Modem-only
operation is impossible.
PGURSB101 Optional remote server management board (PCI) � � � � � � � � � �CPU, External Interface (10BASE-T/RS232C), External PowerSupply
(AC adapter - Option) are on the board
PG-RSBOP1 Optional Kit for mounting RSB for N400/H200 � � � �ServerView for RSB CD-ROM, Connector, Power Code are included
PG-RSBOP2 Optional Kit for mounting RSB for N800 � �RSB Utility FPD, Connector, Power Code are included
PG-RSBOP3 Optional Kit for mounting RSB for B225 � �RSB Utility FPD, Connector, Power Code are included
PG-RSBOP4 Optional Kit for mounting RSB for B125 � �RSB Utility FPD, Connector, Power Code are included
71
�Hardware List
Hardw
areList
Specifications are subject to change without notice. For the latest detailed information, contact your local representative.
All brand names and product names are trademarks and registered trademarks of their respective holders.
©2001 Fujitsu Limited. All rights reserved. Printed in Japan.
PRIMERGY (IA-Servers) Business Development Dept.
Business Development and Marketing Division
Computer Systems Group
Phone: +81-3-3548-3810 Fax: +81-3-3548-3776
URL http://primergy.fujitsu.com/en/
BK0065-12NS