Table of contents

1 Safety 42 About this manual 52.1 Intended audience 52.2 Alerts and notice signs 52.3 Copyright and disclaimer 52.4 Document history 6

3 System installation overview 73.1 Typical system setup 83.2 System extension 10

4 System installation design and planning 144.1 System capabilities 144.2 Hardware requirements 164.3 Power supply capacity calculation plan 174.3.1 Calculation using DCNM-APS(2) or DCNM-PS(2) 174.3.2 Calculation using PoE switches 194.4 Redundancy options 214.4.1 Redundant cabling for DCNM‑APS/DCNM‑PS units 224.4.2 Redundant cabling for DCNM-APS2/DCNM-PS2 units 234.4.3 Redundant server PC 25

5 Installation material and tools 265.1 System Network Cable 265.2 System Cable Connectors 275.2.1 DCNM-CBCON-I Installation Cable Connectors 285.2.2 DCNM-CBCON-N Network Cable Connectors 285.3 DCNM-CBTK System Network Cable Toolkit 295.4 DCNM-CB250 System Installation Cable 30

6 Mechanical installation of Central Equipment 316.1 Audio Powering Switch and Powering Switch 31

7 Mechanical installation of Contribution Devices 347.1 DICENTIS devices 347.2 DICENTIS Microphones 387.3 DCNM-MMDSP Anti-reflection foil 407.4 DCNM-NCH Name Card Holder 40

8 Installation Test 41

DICENTIS Table of Contents | en 3

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 4: Hardware Installation Manual

SafetyPrior to installing or operating products, always read the Important Safety Instructions whichare available as a separate multilingual document: Important Safety Instructions (Safety_ML).These instructions are supplied together with all equipment that can be connected to themains supply.

Safety precautionsSome of the DICENTIS Conference System products are designed to be connected to thepublic mains network.To avoid any risk of electric shock, all interventions must be carried out with disconnectedmains supply.Interventions with the equipment switched on are authorized only when it is impossible toswitch the equipment off. The operation must only be performed by qualified personnel.

Old electrical and electronic appliancesElectrical or electronic devices that are no longer serviceable must be collected separately andsent for environmentally compatible recycling (in accordance with the European WasteElectrical and Electronic Equipment Directive).To dispose of old electrical or electronic devices, you should use the return and collectionsystems put in place in the country concerned.

1

4 en | Safety DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 5: Hardware Installation Manual

About this manualThe purpose of this manual is to provide information required for installing the DICENTISConference System.This installation manual is available as a digital document in the Adobe portable documentformat (PDF).For more information, refer to the product related information on www.boschsecurity.com

Intended audienceThis hardware installation manual is intended for installers of a DICENTIS Conference System.

Alerts and notice signsFour types of signs can be used in this manual. The type is closely related to the effect thatmay be caused if it is not observed. These signs - from least severe effect to most severeeffect - are:

Notice!

Containing additional information. Usually, not observing a ‘notice’ does not result in damage

to the equipment or personal injuries.

!

Caution!

The equipment or the property can be damaged, or persons can be lightly injured if the alert

is not observed.

!Warning!

The equipment or the property can be seriously damaged, or persons can be severely injured

if the alert is not observed.

Danger!

Not observing the alert can lead to severe injuries or death.

Copyright and disclaimerAll rights reserved. No part of this document may be reproduced or transmitted in any form byany means, electronic, mechanical, photocopying, recording, or otherwise, without the priorwritten permission of the publisher. For information on getting permission for reprints andexcerpts, contact Bosch Security Systems B.V..The content and illustrations are subject to change without prior notice.

2

2.1

2.2

2.3

DICENTIS About this manual | en 5

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 6: Hardware Installation Manual

Document history

Release date Documentation version Reason

2013.08 V1.0 1st edition.

2014.07 V1.1 2nd edition.New sections: 1 WEEE, 3.2system ext, 5.2.1, 5.2.2.Sections updated: 2.4, 4.3.2,5.2, 5.3, 5.4, 7.2 +DCNM‑MICx added.

2014.10 V1.2 3rd edition.Sections updated: 2.4, 3.2,4.1 and 4.3.1.

2015.07 V1.3 4th edition.New section: 4.4, includingsub-sections: 4.4.1, 4.4.2, and4.4.3.Sections updated: 2.4, 3.1,3.2, 4.1, 4.3, 4.3.1, 5.3, 5.4,6.1, 7.4, 8.

2015.11 V1.31 5th edition.Sections updated: 2.4, 7.1.Terminology updated.

2016.07 V1.4 6th edition.Terminology updated. DCN multimedia changed toDICENTIS.Sections updated: 3.1, 3.2,4.1, 4.3.1, 4.3.2, 4.4.1, 4.4.2,4.4.3, 5.3, 5.4, 7.1, 7.2, 7.3,7.4, 8.

2.4

6 en | About this manual DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 7: Hardware Installation Manual

System installation overviewIt is advisable to participate in the DICENTIS Conference System training before you install,configure, prepare, and operate a DICENTIS Conference System. The DICENTIS Conference System is an IP based conference system which runs on an OMNEOcompatible Ethernet network. It is used for distributing and processing audio, video and datasignals.The DICENTIS Conference System can be quickly and easily configured as a daisy‑chainconfiguration or as a star configuration:– Daisy‑chain configuration: Uses dedicated cabling, consisting of CAT‑5e cables including

two additional power conductors (see Typical system setup, page 8).– Star configuration: Each DICENTIS device is connected with an individual standard

CAT‑5e cable. An Ethernet switch is also required for providing Power over Ethernet(PoE).

Notice!

When Power over Ethernet is used, DICENTIS devices cannot be daisy‑chained.

See also– Typical system setup, page 8

3

DICENTIS System installation overview | en 7

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 8: Hardware Installation Manual

Typical system setup

1

8

2

4 3

9

8

8

6666

5

88

8

7

6

5.1

5.2

Figure 3.1: Typical DICENTIS Conference System setup

A typical DICENTIS Conference System consists of:1. System server controller (PC):

– The heart of the system. It licenses functionality, configures and controls the system.2. Client PC:

– Can be used to: Manage meetings, prepare meetings and configure the system.3. Audio Powering Switch (DCNM-APS / DCNM-APS2):

– Controls the system audio, routes audio from and to the system and supplies powerto the DICENTIS devices.

4. Powering Switch (DCNM-PS / DCNM-PS2):– Is used to increase the number of DICENTIS devices connected to the system.

5. DICENTIS devices): DCNM-D, DCNM-DVT, DCNM-DSL, DCNM-DE / DCNM-MMD, DCNM-MMD2:– Participants can use their DICENTIS device to contribute to a meeting.– 5.1 is a DICENTIS multimedia Device used for “system power on/off”. This device is

always connected to the powered socket of the Audio Powering Switch or PoweringSwitch.Note: Only one DICENTIS multimedia Device should be connected here.

– 5.2 is a DICENTIS device used via a “Power over Ethernet” (PoE) Ethernet switch.Note: Only one DICENTIS device should be connected here.

6. System Network Cable (DCNM‑CBxxx):– Connects DICENTIS devices, the Audio Powering Switch, and one or more Powering

Switches to each other.7. Ethernet switch:

– Ethernet switch with PoE on some ports. - Routes the system data via Ethernet. - Provides power to the DICENTIS devices via PoE.

8. CAT‑5e Ethernet cable (minimum requirement).9. Optional HD Conference Dome (VCD‑811-IWT) + external power supply:

– Captures the image of a speaking participant.

3.1

8 en | System installation overview DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 9: Hardware Installation Manual

This system overview does not give information on redundant network options. For moreinformation, refer to Redundancy options, page 21.

DICENTIS System installation overview | en 9

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 10: Hardware Installation Manual

System extensionThe DICENTIS Conference System is scalable from small to medium to large. This sectiondescribes what a small, medium and large system is and what the requirements are for thesesystems: A small DICENTIS Conference System (see Typical system setup, page 8) consists of:– up to 100 DICENTIS devices.– all DICENTIS devices in 1 subnet.– 1 DICENTIS Audio Powering Switch for the audio processing.– 1 Server PC which hosts the DICENTIS services. A medium DICENTIS Conference System consists of:– up to 450 DICENTIS nodes.

Refer to table X about the node count of DICENTIS equipment.– all DICENTIS devices in 1 subnet.– 1 DICENTIS Audio Powering Switch for the audio processing.– 1 Server PC which hosts the DICENTIS services.– 1 ARNI-Standard to increase the size of the system. A large DICENTIS Conference System consists of:– up to 750 DICENTIS devices.– multiple subnets connected by use of a router/L3 switch.

– Each subnet can have up to 450 DICENTIS nodes.Refer to the following table for the node count of DICENTIS equipment.

– The first subnet has:- 1 DICENTIS Audio Powering Switch for the audio processing.- 1 Server PC which hosts the DICENTIS services.- 1 ARNI-Enterprise to increase the size of the system.

– All other subnets have 1 ARNI-Standard to increase the size of the system.Note: There is no DICENTIS Audio Powering Switch in the other subnets.

Device Node count

DICENTIS server 0

DICENTIS meeting application 0

DICENTIS Audio Powering Switch 1

DICENTIS Powering Switch 1

DICENTIS multimedia device 2

DICENTIS discussion device 1

DICENTIS discussion device select language 1

DICENTIS discussion device voting 1

DICENTIS discussion device extended 1

ARNI‑E OMNEO interface 0

ARNI‑S OMNEO interface 0

Table 3.1: Nodes count of DICENTIS equipment

3.2

10 en | System installation overview DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 11: Hardware Installation Manual

An ARNI (Audio Routed Network Interface) is used to increase the number of DICENTISdevices on a single subnet and to connect multiple DICENTIS system subnets. If more thanone subnet is required, two types of an ARNI must be used.– OMN-ARNIS (ARNI‑S OMNEO interface): The ARNI‑S is required for increasing the system

size above 100 DICENTIS devices. It supports up to 450 DICENTIS nodes in its subnet. Italso acts as a DHCP server in its subnet.

– OMN-ARNI‑E (ARNI‑E OMNEO interface): The ARNI‑E is required for increasing the systemsize above 450 DICENTIS nodes. It supports up to 450 DICENTIS nodes in its subnet. Italso acts as a DHCP server in its subnet. It can connect up to 40 subnets, each with anARNI‑S.

Defining subnets and subnet masksA subnet is a logical, visible subdivision of an IP network. The number of DICENTIS devicesthat can be in the same subnet depends on the subnet mask.A standard class C subnet (255.255.255 or /24) can contain 254 IP addresses. SomeDICENTIS devices have 2 IP addresses. For this reason, Bosch advises to use 255.255.252.0(or /22) as a subnet mask. This allows you to have 1018 IP addresses. The following table liststhe number of IP address per DICENTIS device in a DICENTIS Conference System.

Device IP addresses

DICENTIS server (optional Meeting Application) 1

Client PC running DICENTIS meeting application 1

DICENTIS Audio Powering Switch 1

DICENTIS Powering Switch 1

DICENTIS multimedia device 2

DICENTIS discussion device 1

DICENTIS discussion device select language 1

DICENTIS discussion device voting 1

DICENTIS discussion device extended 2

ARNI‑Enterprise 1

ARNI‑Standard 1

IP camera 1

SDI video switcher 1

Table 3.2: Nodes count of DICENTIS equipment

Maximum number of DICENTIS devices in a string:– The max age timer should be set to 22 when RSTP is used for cable redundancy to

prevent a defective cable or powering switch from influencing the system.– Each time data hops from one switch to another, the age is increased by one. This timer

can be reached or exceeded, because a daisy chain can be used to loop through theDICENTIS devices.

DICENTIS System installation overview | en 11

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 12: Hardware Installation Manual

– This timer (or restriction) cannot be reached when there is no cable redundancy. This isbecause the power limitation will be reached before the max age restriction is reached.

– The timer can be reached when:– you use cable redundancy.– the system is incorrectly wired.

12 en | System installation overview DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 13: Hardware Installation Manual

Multi subnet DICENTIS Conference SystemThe following figure illustrates a typical multi subnet DICENTIS Conference System with a totalof 1200 DICENTIS devices.– The system is divided over four (4) subnets, where two (2) subnets having a maximum of

400 DICENTIS devices and an OMN-ARNIS are connected.– The system has one OMN-ARNIS installed in the first subnet with a maximum of 400

DICENTIS devices connected (Note that only one OMN-ARNIS is allowed within a multiplesubnet DICENTIS Conference System).

– Subnet four (4): When using multiple subnets, make sure that all cameras needed tocapture video of the seats are all connected to the same subnet.

192.168.64.x

OMN-ARNI-E

192.168.64.1

VLAN64

192.168.65.254

Ports 1, 2, 3, 4

L3 Switch

VLAN66

192.168.67.254

Ports 5, 6, 7, 8

VLAN74 (internet)

192.168.1.253

Ports 17, 18, 19, 20

VLAN68

192.168.69.254

Ports 9, 10, 11, 12

VLAN70

192.168.71.255

Internal DHPC server

Ports 13, 14, 15, 16

Internet Router

192.168.1.254

DCNM-APS

DCNM server PC

DCNM-PS

DICENTIS devices

Max. 420 nodes

DICENTIS devices

Max. 420 nodes

DICENTIS devices

Max. 420 nodes

DCNM-PS

OMN-ARNI-S

192.168.66.1

OMN-ARNI-S

192.168.68.1

192.168.66.x

192.168.1.x

192.168.68.x

192.168.70.x

12

Figure 3.2: Typical DICENTIS Conference System with multiple subnets

– 1: External video switcher.– 2: Dome camera.

See also– System extension, page 10

DICENTIS System installation overview | en 13

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 14: Hardware Installation Manual

System installation design and planningBefore you start to install system devices and connect system cabling, you should make asystem design and planning:– Familiarize yourself with the product and system capabilities.– Make a cable (connection) plan:

– Calculate the system network cable length.– Calculate the system power consumption.– Calculate the required power capacity of the system.

Notice!

The DICENTIS Conference System uses the RSTP protocol when redundant cabling mode is

enabled. If the DICENTIS Conference System needs to be connected with the locally present

network, please consult the local IT department before continuing with the installation

design.

Notice!

Make sure that the cable lengths and power consumptions do not exceed the specifications.

Not doing so will result in malfunctioning at any moment of the DICENTIS Conference System

and products.

System capabilitiesThe capability of the DICENTIS Conference System and DICENTIS products depends on:– The lengths of the system network cables.– The number of connected devices.– The system power supply capacity.

Cable lengthSystem network cables (DCNM‑CBxx) lengths (2, 5, 10 or 25 m) have a direct effect on theavailable power supply capacity. The longer the system network cable, the less power supplycapacity is available to drive the connected devices. Therefore, choose the lengths of thesystem network cables carefully.

Notice!

Custom network cables must never exceed the maximum Ethernet specification of 100m

(IEEE 802.3ab).

Keep your network hierarchy as flat as possible. This means having as few levels as possible.

It is recommended not to exceed 7 levels. See the following example: 1: 1st level = Root

switch, 2: 2 nd level = switch, 3: 3 rd level = switch.

4

4.1

14 en | System installation design and planning DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 15: Hardware Installation Manual

1

2 2 2 2

3 3 3 3

Figure 4.1: Example: Switch-levels

Power supply capacityThe total system network cable length and connected devices determine the required powersupply capacity. The power within the DICENTIS Conference System is supplied by:– The Audio Powering Switch and the Powering Switch, or– Off‑the‑shelf PoE Ethernet switches.

Calculation toolThe calculation tool can be used to calculate the total power capacity of the system. Thismakes the design and planning of the DICENTIS Conference System easier. The calculationtool uses the power consumption of the devices and the system network cable lengths tocalculate the needed system power supply capacity.The calculation tool is on the DVD supplied with the Audio Powering Switch and is part of theDICENTIS software DCNM.iso file. The DCNM.iso file can be downloaded from the Boschwebsite at: https://licensing.boschsecurity.com/software

DICENTIS System installation design and planning | en 15

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 16: Hardware Installation Manual

Hardware requirementsSwitchesThe following minimal requirements apply to switches:– 1 Gbit or higher with hardware switching capabilities.– Quality of Service through differentiated services with 4 or more output queues and strict

priority packet scheduling.– (Optional) IGMPv3 or IGMPv2 snooping. To optimize bandwidth usage, IGMP snooping

can be used. This is useful in systems with >10 multicast streams, although not absolutelyrequired. Sufficient performance for handling a large number of IGMP query responses,depending on the number of (directly or indirectly) connected devices to that switch.Hardware support for IGMP is strongly recommended.

– (Optional) (Rapid) Spanning Tree support, in case redundant networks are used.– (Optional) SNMPv3 support for switch supervision purposes.

RoutersThe following minimal requirements apply to routers:– 1 Gbit or higher Ethernet ports.– Supports PIM‑DM or Bidirectional PIM.– Performs IP routing in hardware (i.e. a ‘layer 3 switch’) to minimize the routing delay.– Packet forwarding rate > 1,000,000 packets per second per port (e.g. 8 Mpps for an

8‑port router).– Non-blocking backplane per switching port, i.e. 2 Gbit per port (e.g. 16 Gbps for an

8‑port router).– MAC address table of at least 1000 addresses per directly connected subnet.

4.2

16 en | System installation design and planning DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 17: Hardware Installation Manual

Power supply capacity calculation planHow to start

Notice!

It is advisable to use the power calculation tool. The calculation tool is on the DVD supplied

with the Audio Powering Switch and is also part of the DICENTIS software DCNM.iso file,

which can be downloaded from the Bosch website at: https://licensing.boschsecurity.com/

software

Decide how to supply power to the DICENTIS devices:– Using the Audio Powering Switch and one or more Powering Switches.– Using one or more PoE Ethernet switches.If you want to use PoE Ethernet switches, continue with chapter Calculation using PoEswitches, page 19.

See also– Calculation using DCNM-APS(2) or DCNM-PS(2), page 17– Installation material and tools, page 26

Calculation using DCNM-APS(2) or DCNM-PS(2)

Notice!

If you want to use customized cables, or a more accurate power supply capacity calculation

plan is needed, you should use the power calculation tool.

To calculate the total power supply capacity:1. Count all DICENTIS devices.2. Know the exact location where the devices are installed.3. Count each system network cable of the same length.

Device type Power consumption (Watts)

DCNM-D 3.1

DCNM-DSL 3.6

DCNM-DVT 3.7

DCNM-DE 5.00

DCNM-MMD 11.30

DCNM-MMD2 12.00

DCNM‑CB02 1.19

DCNM‑CB05 2.43

DCNM‑CB10 4.50

DCNM‑CB25 10.71

Table 4.1: Power consumption (Watts)

4.3

4.3.1

DICENTIS System installation design and planning | en 17

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 18: Hardware Installation Manual

Ordering number Cable lengths

m ft

DCNM-CB02 2 6.56

DCNM-CB05 5 16.40

DCNM-CB10 10 32.81

DCNM-CB25 25 82.02

Table 4.2: Cable types and lengths

Rear view

10 12 13 15 17 19

11 14 16 18 20

1 2 3 4 5 6 7 8 9

Figure 4.2: Audio Powering Switch

10 12 13 15 17

14 16 18

19

20

9

Figure 4.3: Powering Switch

Item Description

1, 5 XLR line outputs 1 and 2.

2, 6 RCA line outputs 1 and 2.

3, 7 XLR line inputs 1 and 2.

4, 8 RCA line inputs 1 and 2.

9 Mains inlet, mains switch and fuse holder.

10 Reset button.

11 Ground switch (grounded or floating).

12 Socket 1 without power.

13 Socket 2 low power.

18 en | System installation design and planning DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 19: Hardware Installation Manual

Item Description

15, 17, 19 Socket 3, 4, 5 high power.

14, 16, 18, 20 Overload LED for sockets 2‑5:Green: Power OK.Red: Overload. Remove cable and wait a few seconds for the system toreset the overload.

Network and Power connector Max. power output (W) Max. devices

Socket 1 (12) No power capacity ---

Socket 2 (13) 15 1

Socket 3 (15) 144 40

Socket 4 (17) 144 40

Socket 5 (19) 144 40

Table 4.3: Power supply capacity DCNM‑APS(2) / DCNM‑PS(2)

Calculation examplesThe following example gives you an indication of the maximum load to each socket of an AudioPowering Switch or Powering Switch.– Socket 2: 50 m cable + DCNM-MMD2 = 12 W1

– Socket 3: 10 m cable + DCNM-MMD2 + 9x (2 m cable + DCNM-MMD2)= (4.5 + 12) + 9x(1.19 + 12) = 135.21 W2.

– Socket 4: 10 m cable + DCNM-D + 19x (2 m cable +DCNM-D)= (4.5 + 3.1) + 19x(1.19 + 3.1) = 89.11 W2.

– Socket 5: 10 m cable + DCNM-DE + 19x (2 m cable + DCNM-DE) = (4.5 + 5) + 19x(1.19 + 5) = 127.11 W2.

1 For socket 2, the cable power consumption of the cable does not need to be counted if only one device is connected to this output.

2 The shortest redundant cable does not need to be counted.

Calculation using PoE switchesSelect one or more PoE Ethernet switches to supply power to the DICENTIS devices. EachDICENTIS device must be connected to an individual PoE enabled output of an Ethernetswitch.

Notice!

Some PoE Ethernet switches can only supply power to a limited number of ports. Others can

supply power to every port, but the total power the Ethernet switch can supply is limited.

Please consult the documentation of the PoE Ethernet switch used.

Notice!

Using PoE, DICENTIS devices cannot be daisy‑chained connected. Using PoE does not provide

redundant cabling.

4.3.2

DICENTIS System installation design and planning | en 19

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 20: Hardware Installation Manual

2

1

Figure 4.4: Bottom view DICENTIS devices (DCNM-MMD / DCNM-MMD2)

2

1

Figure 4.5: Bottom view DICENTIS devices (DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DE)

Item Description

1 Network connector

2 Network/PoE connector

20 en | System installation design and planning DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 21: Hardware Installation Manual

Redundancy optionsDICENTIS Conference Systems can be created with network redundancy. This ensures that thesystem will continue to work if:– a network cable is defective or accidentally disconnected.– one of the components fails. Different levels of redundancy can be created in the system depending on:– the type of unit used in the system (DCNM-APS / DCNM-PS or DCNM-APS2 / DCNM-PS2)– the number of redundant components used in the system.– the amount of redundant network cabling. The following sections explain the redundancy options that can be used when designing yourDICENTIS Conference System. Each option can be combined in the DICENTIS ConferenceSystem, providing you observe the redundant cabling limitations. Refer to:– Redundant cabling for DCNM‑APS/DCNM‑PS units, page 22.– Redundant cabling for DCNM-APS2/DCNM-PS2 units, page 23.– Redundant server PC, page 25.

Notice!

Rapid Spanning Tree Protocol (RSTP) must be enabled in the DICENTIS Conference System

for these redundancy options to work correctly.

4.4

DICENTIS System installation design and planning | en 21

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 22: Hardware Installation Manual

Redundant cabling for DCNM‑APS/DCNM‑PS unitsThis section describes how to create redundant cabling for DCNM-APS or DCNM-PS units. Themaximum number of Ethernet devices in the loop (including the root switch) is 22. In a systemwith no Ethernet switch(es), the APS is the root switch.The total number of devices allowed in a loop depends on:– The type of device connected in the loop (for example, DCNM-MMD2 devices consume

more power than DCNM-DE devices).– The length of the loop (cable also consumes power).The figure shows how to calculate the number of devices in the loop. The red line shows thelargest loop. The # sign shows the way the devices are counted.In the example below up to 21 discussion devices can be connected.

1

2

3 3

#1

#2 #22

Figure 4.6: DICENTIS devices connected with redundant cabling to the same DCNM-APS / DCNM-PS type

unit

1: DCNM-APS or DCNM-PS.2: DICENTIS devices.3: DICENTIS cabling (redundant loop).

Cabling possibilities (DCNM‑APS/DCNM‑PS) Limitations/requirements

Connect the DICENTIS devices in a daisychain configuration from a high power socketon a DCNM-PS or DCNM-APS to another highpower socket on the same DCNM-PS orDCNM-APS.

The redundancy is for cable only. If theDCNM-PS or DCNM-APS fails, all DICENTISdevices connected to that unit will also fail. If a single DICENTIS device fails, the otherDICENTIS devices in the daisy chain willcontinue to work. To enable redundancy, Rapid Spanning TreeProtocol (RSTP) must be enabled.

You can use any of the high power sockets (3,4, or 5) to create the daisy chain.

The redundant loop must be connected tothe same DCNM-APS or same DCNM-PS.

See also– Power supply capacity calculation plan, page 17

4.4.1

22 en | System installation design and planning DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 23: Hardware Installation Manual

Redundant cabling for DCNM-APS2/DCNM-PS2 unitsThis section describes how to create redundant cabling for DCNM-APS2 / DCNM-PS2 typeunits. The maximum number of Ethernet devices in the largest possible loop (including theroot switch) is 22. In a system with no Ethernet switch(es), the APS is the root switch.The total number of devices allowed in a loop depends on:– The type of device connected in the loop (for example, DCNM-MMD2 devices consume

more power than DCNM-DE devices).– The length of the loop (cable also consumes power).The figure shows how to calculate the number of devices in the loop. The red line shows thelargest loop. The # sign shows the way the devices are counted.In the example below up to 19 discussion devices can be connected.

#1

#2 #22

#3 #21

1

3 4

5 5

5 5

5 5

4 4

2

Figure 4.7: DICENTIS discussion devices connected with redundant cabling between DCNM-PS2 / DCNM-

APS2 type units

1: DICENTIS system/client PC.2: Network switch (with optional redundant power supply)3: DCNM-APS24: DCNM-PS25: DICENTIS cabling (redundant loop)

4.4.2

DICENTIS System installation design and planning | en 23

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 24: Hardware Installation Manual

Cabling possibilities (DCNM-APS2/DCNM-PS2)

Limitations/requirements

Create a redundant loop by connecting theDICENTIS devices in a daisy chainconfiguration from a high power socket on aDCNM-PS2 / DCNM-APS2 to a high powersocket on another DCNM-PS2. The redundant loop between two DCNM-PS2units is for power and signal. If one of theDCNM-PS2 units fails, the other DCNM-PS2unit will supply power and signal to theDICENTIS devices in the daisy chain.

The redundancy is for cable only. If theDCNM-PS or DCNM-APS fails, all DICENTISdevices connected to that unit will also fail. To enable redundancy:– Rapid Spanning Tree Protocol (RSTP)

must be enabled in the DICENTISConference System.

– a network switch with redundant powersupply, should be connected to theDCNM-PS2 / DCNM-APS2 units, asshown in the previous figure.

You can use any of the high power sockets (3,4, or 5) on either of the DCNM-PS2 units tocreate the daisy chain/redundant loop.For example, high power socket 3 on one unitcan be connected to high power socket 4 onanother unit.

Note: The redundant loop must be connectedto another DCNM-PS2 type unit. You cannotuse DCNM-PS / DCNM-APS type units tocreate redundant loops for power.

You can create a redundant loop for signalonly, by connecting the DICENTIS devices in adaisy chain configuration to the same DCNM-PS2 or DCNM-APS2, although this is notrecommended.The DCNM-PS2 unit is designed to reducecost of ownership, for example, by allowing amaximum of three redundant loops to beconnected between two DCNM-PS2 units.

The redundant loop will function in the sameway as a DCNM-PS / DCNM-APS type unit.Refer to Redundant cabling for DCNM‑APS/DCNM‑PS units, page 22.

Notice!

Rapid Spanning Tree Protocol (RSTP) must be enabled in the DICENTIS Conference System

for these redundancy options to work correctly.

See also– Power supply capacity calculation plan, page 17

24 en | System installation design and planning DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 25: Hardware Installation Manual

Redundant server PCSystem availability can be improved by connecting a redundant DICENTIS server PC and theassociated components and cables to the DICENTIS Conference System. The maximumnumber of Ethernet devices in the largest possible loop (including the root switch) is 22.The total number of devices allowed in a loop depends on:– The type of device connected in the loop (for example, DCNM-MMD2 devices consume

more power than DCNM-DE devices).– The length of the loop (cable also consumes power).The figure shows how to calculate the number of devices in the loop. The red line shows thelargest loop. The # sign shows the way the devices are counted.In the example below up to 17 devices can be connected.

#4 #20

#2

#3 #21

#22

#1

1

1

4 4

5

5

5

3

22

Figure 4.8: Redundant DICENTIS server PC with redundant components and cables

1: DICENTIS system/client PC2: Network switch (with optional redundant power supply)3: DCNM-APS24: DCNM-PS25: DICENTIS cabling (redundant loop) For this option to work the DICENTIS Conference System has to be run in combination withEverRun Enterprise software from Stratus Technologies. For more information, refer to theStratus Technologies website.Other options that can be used for guaranteeing the reliability of the DICENTIS ConferenceSystem include:– Remote SQL servers.

4.4.3

DICENTIS System installation design and planning | en 25

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 26: Hardware Installation Manual

Installation material and toolsThis section describes installation material such as cables, connectors and tools.

Recommedations– Always use manufacturer specified installation products, materials and tools.– In general, use different cable ducts for the system network cables, audio cables and

mains supply cables.– In public areas where people can touch or move above the connectors and cables, use

metal protection covers.

!Warning!

Do not exceed the bend limitations of system network cables (DCNM‑CBxxx):

The minimum bend radius of the system network cable is 50 mm radius.

System Network CableThe system network cables, terminated with connectors on both ends, are available indifferent lengths and are used to connect DICENTIS devices to each other. The cable consistsof four CAT‑5e twisted pairs to transmit data and two copper wires to supply the power.

Ordering number Cable lengths

m ft

DCNM-CB02 2 6.56

DCNM-CB05 5 16.40

DCNM-CB10 10 32.81

DCNM-CB25 25 82.02

Table 5.1: Cable types and lengths

Figure 5.1: DCNM-CBxx cable and connector view

5

5.1

26 en | Installation material and tools DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 27: Hardware Installation Manual

System Cable ConnectorsThe connectors are used to make your own system network cables or to replace a connector.Two types of system cable connectors are available: DCNM-CBCON-I Installation CableConnectors, page 28 and DCNM-CBCON-N Network Cable Connectors, page 28.

!

Caution!

Both connector types look similar but are different! So, only use the right type of connector

with the right type of system cable.

12

3

5

79

8

6

4

43

1

5

6

7

9

8

12

3

5

79

8

6

4

43

1

5

6

7

9

8

Figure 5.2: DCNM-CBCON Front and exploded view

Item Description

1 Strain relief boot

2 Ferrule

3 Plug connector shield

4 Power contacts (Qty: 2)

5 Load bar

6 Power contact cavity (2 places)

7 Housing

8 Locking latch

9 Signal contact cavity (8 Places)

See also– System Network Cable, page 26– DCNM-CB250 System Installation Cable, page 30– DCNM-CBTK System Network Cable Toolkit, page 29

5.2

DICENTIS Installation material and tools | en 27

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 28: Hardware Installation Manual

DCNM-CBCON-I Installation Cable ConnectorsThe DICENTIS 50 Installation Cable Connectors DCNM‑CBCON‑I can only be used with the theDCNM-CB250 System Installation Cable, page 30 by using the DCNM-CBTK System NetworkCable Toolkit, page 29.

DCNM-CBCON-N Network Cable ConnectorsThe DICENTIS 50 Network Cable Connectors DCNM‑CBCON‑N can only be used with theSystem Network Cable, page 26 by using the DCNM-CBTK System Network Cable Toolkit, page29.

5.2.1

5.2.2

28 en | Installation material and tools DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 29: Hardware Installation Manual

DCNM-CBTK System Network Cable ToolkitThe system network cable toolkit is used to connect the System Cable Connectors, page 27 tothe DCNM-CB250 System Installation Cable, page 30 or System Network Cable, page 26.

21

Item Description

1 Power wiring tool.

2 Signal wiring tool.

Table 5.2: Toolkit content

Notice!

Please consult the “custom length for system network cables” section on the DVD, which can

be downloaded at: https://licensing.boschsecurity.com/software

5.3

DICENTIS Installation material and tools | en 29

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 30: Hardware Installation Manual

DCNM-CB250 System Installation CableThe system installation cable, without connectors, is available in a length of 250 meters and isused for making your own system network cable. Refer also to the sections System CableConnectors, page 27, DCNM-CBCON-I Installation Cable Connectors, page 28 and DCNM-CBTKSystem Network Cable Toolkit, page 29.

Notice!

The maximum system network cable length is: 100 m / 328,9 ft.

Notice!

Please consult the “custom length for system network cables” section on the DVD, which can

be downloaded at: https://licensing.boschsecurity.com/software

See also– System Cable Connectors, page 27

5.4

30 en | Installation material and tools DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 31: Hardware Installation Manual

Mechanical installation of Central Equipment

Audio Powering Switch and Powering SwitchThe Audio Powering Switch is used:– to control system audio signals,– to route audio signals to/from devices,– to supply power to devices,– as an Ethernet switch to connect the PC and DICENTIS devices (DCNM-D / DCNM-DVT /

DCNM-DSL / DCNM-DE / DCNM-MMD / DCNM-MMD2).The Powering Switch is used to:– supply power to devices.

Scope of deliveryThe Audio Powering Switch and Powering Switch are shipped with the following parts:– 1x Mains power cord.– 1x Safety instructions.– 1x Set of 19 inch mounting brackets.– 4x bottom feet.– 1x DVD containing manuals and software (only with Audio Powering Switch).

Front view

1 2 2 13

Figure 6.1: Audio Powering Switch / Powering Switch

Item Description

1 19“ mounting brackets.

2 Ventilation inlet.

3 Indication LED:Off: Switched off.Green: Switched on.Amber: Standby.Blinking: Services on the server PC are not running.Alternating green amber: When a software download is required.

6

6.1

DICENTIS Mechanical installation of Central Equipment | en 31

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 32: Hardware Installation Manual

Rear view

10 12 13 15 17 19

11 14 16 18 20

1 2 3 4 5 6 7 8 9

Figure 6.2: Audio Powering Switch

10 12 13 15 17

14 16 18

19

20

9

Figure 6.3: Powering Switch

Item Description

1, 5 XLR line outputs 1 and 2.

2, 6 RCA line outputs 1 and 2.

3, 7 XLR line inputs 1 and 2.

4, 8 RCA line inputs 1 and 2.

9 Mains inlet, mains switch and fuse holder.

10 Reset button.

11 Ground switch (grounded or floating).

12 Socket 1 without power.

13 Socket 2 low power.

15, 17, 19 Socket 3, 4, 5 high power.

14, 16, 18, 20 Overload LED for sockets 2‑5:Green: Power OK.Red: Overload. Remove cable and wait a few seconds for the system toreset the overload.

32 en | Mechanical installation of Central Equipment DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 33: Hardware Installation Manual

How to install1. Install the Audio Powering Switch or Powering Switch in a 19 inch device rack system or

on a flat surface. Two 19 inch mounting brackets and four bottom feet are supplied withthe Audio Powering Switch and Powering Switch. Refer to the following illustration.

2. Connect all required cabling.3. Connect the mains supply.

1

2

3

Figure 6.4: 19 inch rack, flat surface and feet mounting

Item Description

1 19 inch rack mounting (bracket)

2 Flat surface mounting (bracket)

3 Feet mounting

Notice!

The unit extends 30 mm in front of the 19” mounting brackets when installed in a 19” rack

system.

!

Caution!

Do not obstruct the airflow vents on the front side and rear left and right sides.

DICENTIS Mechanical installation of Central Equipment | en 33

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 34: Hardware Installation Manual

Mechanical installation of Contribution Devices

DICENTIS devicesThe DICENTIS devices (DCNM-D, DCNM-DVT, DCNM-DSL, DCNM-DE, DCNM-MMD, DCNM-MMD2) are used to:– participate in a meeting or conference.– monitor and control a meeting or conference (chairperson use, depending on the

configuration).

DCNM-MMD / DCNM-MMD2

1

4

5

78 6

9

10

32

Figure 7.1: Front, top, rear and side views

Item Description

1 7” capacitive touch screen.

2 LED strip.

3 Two‑way loudspeaker.

4 3.5 mm stereo jack for headphone or headset with integrated microphone.

5 Headphone volume control.

6 Microphone request button.

7 Chairperson priority or microphone mute button.

8 Near Field Communication (NFC) reader (DCNM-MMD2 only).

9 Cable guides.

10 Microphone input connector.

– DCNM-MMD2 is compliant with the Radio Equipment Directive (RED) 2014/53/EU.– Operating frequency is 13.56 MHz. Maximum field strength is 8.05 dBµA/m @ 3m.

7

7.1

34 en | Mechanical installation of Contribution Devices DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 35: Hardware Installation Manual

DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DE

Figure 7.2: Front, top, rear and side views

Item Description

1 Two‑way loudspeaker.

2 Near Field Communication (NFC) reader.

3 Chairperson priority button, microphone mute button, or microphone requestbutton for second participant.

4 Microphone request button.

5 Voting buttons.

6 Language selection buttons.

7 Language display.

8 4.3” capacitive touch screen.

9 3.5 mm stereo jack for headphone or headset with integrated microphone.

10 Headphone volume control.

11 Microphone input connector.

12 Cable guides.

– DCNM-DE, DCNM-DVT and DCNM-DSL are compliant with the Radio Equipment Directive(RED) 2014/53/EU.

– Operating frequency is 13.56 MHz. Maximum field strength is -8.4 dBµA/m @ 10m.

DICENTIS Mechanical installation of Contribution Devices | en 35

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 36: Hardware Installation Manual

Connecting DICENTIS devicesThe DICENTIS Conference System can be quickly and easily configured as a daisy‑chainconfiguration or as a star configuration:– Daisy‑chain configuration: Uses dedicated cabling, consisting of CAT‑5e cables including

two additional power conductors (see Typical system setup, page 8).– Star configuration: Each DICENTIS device is connected with an individual standard

CAT‑5e cable. An Ethernet switch is also required for providing Power over Ethernet(PoE).

Notice!

When Power over Ethernet is used, DICENTIS devices cannot be daisy‑chained.

The star configuration makes use of connectors underneath the devices, ensuring for a neat,tidy system installation, especially advantageous for TV coverage.To connect the system network cables to the DICENTIS devices (refer to the following figure):1. Insert the system network cable/connector (2).2. Lead the system network cable through the cable guides (3).

Installing DICENTIS devicesThe DICENTIS devices can be free-standing or fixed in more permanent installations usingmounting screws.1. The distance between the centres of the screw inserts (1) on the bottom is 100 mm.2. Use M4 type of screws with a device screw insert length of maximum 5 mm when

attaching the device to the bottom of the recess (1).

3 4

1 1

2

Figure 7.3: Bottom view discussion DICENTIS devices (DCNM-MMD / DCNM-MMD2)

36 en | Mechanical installation of Contribution Devices DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 37: Hardware Installation Manual

1 1

3 2

Figure 7.4: Bottom view DICENTIS devices (DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DE)

Item Description

1 Screw insert for fixed installation.

2 2x RJ45 connection input/output for system power cable.

3 Cable guides.

4 USB connector, for future use (DCNM-MMD / DCNM-MMD2 only).

See also– System Network Cable, page 26– DCNM-CB250 System Installation Cable, page 30

DICENTIS Mechanical installation of Contribution Devices | en 37

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 38: Hardware Installation Manual

DICENTIS MicrophonesBoth the DCNM‑HDMIC High Directive Microphone and DCNM-MICL/S Stem Microphone aretypically used with the DICENTIS devices.

3

6 4

7

1

2

5

8

2

64

7

1

2

5

8

Figure 7.5: DCNM‑HDMIC and DCNM‑MICS / DCNM‑MICL front and bottom view

Number Description

1 LED indicator.

2 Microphone grill.

3 Adjustable stem (DCNM‑MICS / DCNM‑MICL).

4 Connection guidance.

5 Slider guidance.

6 Connector plug.

7 Lock-slider for lock release (Press and shift to release).

8 Lock.

9 Device female connector (see following figure).

7.2

38 en | Mechanical installation of Contribution Devices DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 39: Hardware Installation Manual

How to connect or remove the microphoneThe microphone can be easily connected to the DICENTIS devices:

9

6 4

857

Figure 7.6: DCNM‑HDMIC or DCNM-MICS / DCNM-MICL connection

To do so:1. Gently guide the connection guidance (4) into the DICENTIS device microphone

connector (9).2. Gently push the connector plug (6) into the device microphone connector (9) until the

connection lock (5) fits/click into place.3. To remove the microphone from the device: Shift lockslider (7) towards the device and

hold in place lock release (8) and pull out the microphone.

See also– DICENTIS devices, page 34

DICENTIS Mechanical installation of Contribution Devices | en 39

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 40: Hardware Installation Manual

DCNM-MMDSP Anti-reflection foilThe DICENTIS anti‑reflection foil can be used to protect the tempered glass screen of aDICENTIS multimedia Device.

Installation procedure1. Use the included alcohol swab and the microfiber fabric to clean the device LCD screen

before installation.2. Peel the positioning adhesive release paper from the rear of anti‑reflection foil.3. Position the anti‑reflection foil on the device LCD screen, and then fix the positioning

adhesive to the side of the device.4. Open the anti‑reflection foil, and use the “cleaning stick” to clean surface dust from the

LCD screen.5. Peel the protective film from the other side of the anti‑reflection foil.6. Lightly press the anti‑reflection foil on to the LCD screen. If air bubbles are trapped under

the anti‑reflection foil, use the “squeegee” to remove them.

DCNM-NCH Name Card HolderThe name card holder (1) can be used to permanently display the participant’s name on therear of a DICENTIS multimedia Device. The name card holder has two magnets (2) that allow itto be easily attached to, and removed from, the rear of the device.

1 2

2

Figure 7.7: DCNM‑NCH assembly

Item Description

1 Name card holder.

2 Magnets.

Notice!

A paper insert template is included on the DVD that can be downloaded at: https://

licensing.boschsecurity.com/software

7.3

7.4

40 en | Mechanical installation of Contribution Devices DICENTIS

2016.09 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.

Page 41: Hardware Installation Manual

Installation TestAn installation test is needed to prevent connection mismatches and find potential productdefects at an early stage. Not to do so could result in a system malfunctioning.Each DICENTIS device has its own built‑in diagnostics, which can be used for faultfinding. Thediagnostics starts as soon the DICENTIS device is powered on. The DICENTIS ConferenceSystem does not have to be configured with, and connected to, the system controller PC.

Preconditions1. All system network cables are connected to the devices.2. The Audio Powering Switch and Powering Switch(es) are installed.

Start the testPower on the Audio Powering Switches and Powering Switches used in the system: Eachconnected device powers on and initializes.

1. After the DICENTIS multimedia Device and the DICENTIS discussion Extended haveinitialized, the diagnostic screen is shown.

2. If the text “Link down” is shown:– The network cable is not connected or defective.– The device is only connected with one system network cable (“Link down” is shown

on the side where the device is not connected).3. If the system network cable is correctly connected to the network, the network speed is

shown.4. If the DICENTIS multimedia Device and the DICENTIS discussion Extended are connected

to an Audio Powering Switch, Powering Switch or another multimedia device, and 100 Mbis shown:– Not all wiring inside the system network cable connector is correctly connected or

broken. You need to check the wiring and connector.– If the cable is connected to a 100 Mb switch, it is correct.

5. Click the info button to see additional information of the multimedia device.6. When everything is correctly connected, and the device does not have the application

software, it shows the text “Please download software”.7. Now the device can be downloaded:

8

DICENTIS Installation Test | en 41

Bosch Security Systems B.V. Hardware Installation Manual 2016.09 | V1.4 |

Page 42: Hardware Installation Manual

– Downloading devices is not covered in this manual. Refer to the DICENTISconfiguration manual on how to download the devices.

Customer serviceIf a fault cannot be resolved, please contact your supplier or system integrator, or go directlyto your Bosch representative.