hans-ewald schneider - new approaches to museum depots
DESCRIPTION
TRANSCRIPT
![Page 1: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/1.jpg)
0% Risk Standard in Fine Arts
Conservation of Cultural Property –
Eco-friendly storage of masterpieces
European Registrars Conference 2010, Amsterdam
![Page 2: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/2.jpg)
Environmental protection is a global challenge. The conservation of natural resources and their simultaneous utilisation must be regarded as long-term ecological approach, which therefore also represents an investment in the future.
Green Logistics
2
![Page 3: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/3.jpg)
Environmentally neutral
Use of natural energy sources
Highly energy efficient
Benchmark for storage facilities
Our contribution for low emission storage
3
![Page 4: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/4.jpg)
Facts and figures
4 floors Ground floor for packing production 3 storage floors
Floor space: 2.013 m2
Effective area: 7.823 m2
Total cubage: 47.104 m3
4
![Page 5: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/5.jpg)
Facts and figures
All the climate conditions shall fulfill restorers’ and curators’ requirements concerning the appropriate handling of cultural goods:
20°C inside temperature
55% humidity
5
![Page 6: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/6.jpg)
Trend chart of climate conditions
outside temperature
inside temperature
inside humidity
outside humidity
![Page 7: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/7.jpg)
The technology behind
7
![Page 8: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/8.jpg)
The characteristics
Energy supply by using geothermal energy without gas and oil resources
Building insulation due to concrete core conditioning system pumice stone
Alternative climate regulation by using adjustable openings in the buildings' frontage
Geothermal energy enables both, heating and cooling
Climate control due to temperature and humidity sensors
8
![Page 9: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/9.jpg)
The functional principle of geothermal energy
1. Warm ground water Ground water with a temperature of 7-10°C is taken out of a depth of 30 metres under the earths’ surface and led to the hydro-extractor. 2. Hydro-extractor The centrifuge extracts the heat of the ground water, concentrates it and leads it into the heating circle of the building. With now 23°C it can be used for both heating and air-conditioning. 3. Cold ground water The cold ground water is led back under the surface where it will be heated up again for the circulating process.
9
![Page 10: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/10.jpg)
High Security standards
Beside ecological aspects we offer the high security standard you can expect from hasenkamp, so that your artworks are stored safe and secure at any time:
Security class VdS SG3
Video monitoring 24/7
Movement detectors
Burglar alarm with direct connection to the police
Fire alarm with direct connection to the fire department
Fire prevention system
10
![Page 11: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/11.jpg)
We do even more for the environment
Eco-friendly packaging materials
Re-use of packing (cardboards, crates)
Reduction of empty runs caused by optimised routing
Utility vehicles which correspond to the highest European standard (EU 5)
All operational and administrative processes are based on a comprehensive environmental management system in accordance with DIN EN ISO 14001:2004
Annual external quality and environmental audits
Waste separation / waste disposal by certified companies
Use of eco-friendly technical equipment (carpentry, garage, fork lift trucks)
11
![Page 12: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/12.jpg)
Future projects
Photovoltaic technology: collector systems are going to be installed on our
building’s roof
energy supply for all energy consuming processes
remaining energy will be forwarded in the public energy network
Sustainable warehouse planning appropriate to
state-of-the-art technology
12
![Page 13: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/13.jpg)
Bottom line
1. We harmonise ecological and conservatory requirements
2. All operational and administrative processes are continuously developed in accordance with the latest environmental guidelines
3. And adjusted to the latest technology standards
13
![Page 14: Hans-Ewald Schneider - New Approaches to Museum Depots](https://reader034.vdocuments.us/reader034/viewer/2022052303/54bf67404a7959554c8b4576/html5/thumbnails/14.jpg)
For more information please visit
www.hasenkamp.com
© 2010 hasenkamp Holding GmbH | Europaallee 16-18 | 50226 Köln | Tel.: + 49 (0) 2234 104 0