handheld single channel ecg - tmedi.ge · o satisfy different applications. ... 11 with high...

4
MODELECG1200G Product Product Product Product introduction introduction introduction introduction 1 8"TFT Color LCD shows the working status and ECG waveform. Check the wave form before printing to save record paper. 2 12 Leads ECG simultaneous gather, digital signal processing, to get the ECG wav eforms of higher quality through the AC, DFT and EMG filtering of the ECG signals. 3 Simultaneous display of 3/6/12 leads ECG waveform, and the state of printing mo de, sensitivity, speed, filter etc, to be easy for contrast diagnosis. 4 Multiply printing modes and formats, including 12*1, 6*2+1(rhythm lead), 6*2, rh ythm 12, rhythm 10, rhythm 8, rhythm 6, manual and freeze, etc. The length of print ed wave can be adjusted and simultaneity the function of periodic printing is offered t o satisfy different applications. 5 The instrument has the functions of auto-analysis and auto-diagnosis of regular EC G waveform parameters, provides measurement parameters such as HR, P-R interval, P Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V

Upload: trannhu

Post on 10-Apr-2018

218 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Handheld Single Channel ECG - tmedi.ge · o satisfy different applications. ... 11 With high resolution thermal print system ... with ECG parameter auto-detected and analysis reports,

MODEL:ECG1200G

ProductProductProductProduct introductionintroductionintroductionintroduction

1 8"TFT Color LCD shows the working status and ECG waveform. Check the waveform before printing to save record paper.2 12 Leads ECG simultaneous gather, digital signal processing, to get the ECG waveforms of higher quality through the AC, DFT and EMG filtering of the ECG signals.3 Simultaneous display of 3/6/12 leads ECG waveform, and the state of printing mode, sensitivity, speed, filter etc, to be easy for contrast diagnosis.4 Multiply printing modes and formats, including 12*1, 6*2+1(rhythm lead), 6*2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual and freeze, etc. The length of printed wave can be adjusted and simultaneity the function of periodic printing is offered to satisfy different applications.5 The instrument has the functions of auto-analysis and auto-diagnosis of regular ECG waveform parameters, provides measurement parameters such as HR, P-R interval, PDuration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V

Page 2: Handheld Single Channel ECG - tmedi.ge · o satisfy different applications. ... 11 With high resolution thermal print system ... with ECG parameter auto-detected and analysis reports,

1), R(V5)+S(V1), etc and auto-diagnosis conclusion to reduce doctor's burden.6 AC/DC power supply. Built-in rechargeable lithium polymer battery. At the best DC state, it can standby for 10 hours, print less than 3 hours, and print 300 pieces ofECG waveform to satisfy the need of visiting patients and physical examination.7 Built-in MSF, can store more than 1000 cases, convenient for doctor's case reviewand information statistics.8 System provides Chinese/English/Spanish/Turkish operation interface and can printmultiply languages report.9 System provides multiply printing speeds, including 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, and abstract conclusion graph printing.

MainMainMainMain characteristiccharacteristiccharacteristiccharacteristic

10 Display with 800*600 dots color LCD, operate either by buttons or touch screen,which is convenient and quick11 With high resolution thermal print system (8 dots/mm), it needs no adjustment, and the record frequency is up to 150Hz.12 Real-time and continuously record clear and exact 12 channel ECG waveforms andremarks. The remarks include lead sign, sensitivity, paper speed and filter state,etc.13 In auto mode, one button operation to complete record, which will improve workefficiency.14 Full digital filter design, resisting baseline draft, AC and EMG interference.15 Baseline auto adjusted, optimized print setup, selectable rhythm lead.16 Full touch keyboard control makes operations more convenient and the device status are clear and easily read through LCD screen.17 The device can be powered either by AC or DC, with built-in lithium polymer rechargeable battery and auto protection circuit., auto powering off time without operation can be set up.18 This device can record 300 pieces of ECG and print less than 3 hours continuallyin the best DC state.19 This device can store more than 1000 cases, more convenient for data review andstatistic.20 The figure of whole device is elegant and gliding.21 One button operation to complete printing and storing.22 The device adopts digital signal processor, through AC, DFT and EMG filters to obtain electrocardiogram of high quality.23 The device has such functions as measuring, analysing and diagnosing conventional ECG parameters automatically to reduce doctor’s burden and improve work efficiency.24 The device gathers 12-channel ECG signals synchronously and then analyses record modes of such channels as 12*1, 6*2+1, 6*2, rhythm row12, rhythm row10, rhythmrow8, rhythm row6,etc, with multiply report formats.25 With multiply lead display modes, the device can observe 3,6,or 12 lead real-time

Page 3: Handheld Single Channel ECG - tmedi.ge · o satisfy different applications. ... 11 With high resolution thermal print system ... with ECG parameter auto-detected and analysis reports,

waveforms, and display such information as lead-off and printer paper lack, etc, alsowith ECG parameter auto-detected and analysis reports, and record waveforms in auto/manual mode, with database to store patient information.26 Safety type: Class I CF applied part with defibrillation protection.27 The degree of protection against entry liquids: IPX0.28 According to the degree of safety of application in the presence of a flammable anaesthetic mixture with air(or oxygen/nitrous oxide): Equipment not suitable for use inthe presence of the gas above.29 Working pattern classification: continuous running device.

ProductProductProductProduct performanceperformanceperformanceperformance

• Environment conditionsOperationa) Environment temperature: +5℃~+35℃b) Relative humidity: ≤80%c) Power supply: AC:100V~240V,50/60HzDC:18V, 3700 mAh rechargeable lithium batteryd) Atmospheric pressure: 86kPa~106kPaTransportation and Storagea) Environment temperature: -10℃~55℃b) Relative humidity: ≤95%c) Atmospheric pressure: 50kPa~106kPa• Input way: Floating and defibrillation protection• Sampling precision: 12 bits• Lead: Standard 12 leads(model:BIP0057)• Patient leak current: <10μA• Input impedance: ≥50MΩ• Frequency response: 0.05Hz~150Hz(-3dB)• Time constant: Time constant>3.2s• CMRR: >60dB, >100dB( Adding filter)• EMG interference filter: 35Hz(-3dB)• Recording way: Thermal printing system• Specification of recording paper: 210mm(W)*20m(L) high-speed thermal paper• Paper speed:Auto record: 25mm/s, 50mm/s, error:±5%Rhythm record: 25mm/s, 50mm/s, error:±5%Manual record:5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, error:±5%• Sensitivity selections: 2.5,5,10,20,40mm/mV, error:±5%. Standard sensitivity is 10mm/mV±0.2mm/mV.• Auto record: Record setup according to auto record format and mode, automatically changing leads, measuring and analysing.• Rhythm record: record setup according to rhythm record format and mode, automa

Page 4: Handheld Single Channel ECG - tmedi.ge · o satisfy different applications. ... 11 With high resolution thermal print system ... with ECG parameter auto-detected and analysis reports,

tically measuring and analysing.• Manual record: record setup according to manual record format, manually changingleads.• Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration,Q-T interval, Q-Tc, P A*is, QRS A*is, T A*is, R(V5) , S(V1) , R(V5)+S(V1)• Product safety type: Class I CF applied part; there is defibrillation and pacing protection circuit in it.• Enduring polarization voltage: ±500mV• Noise level: ≤15μVp-p• Fuse specification: 2 pcs φ5*20mm AC time lag; T1.6AL 250V• Size: 340mm(L)*320mm(W)*85mm(H)• Net Weight: 3.2Kg

AccessoriesAccessoriesAccessoriesAccessories

• Standard:ECG lead wireLimb electrode clampChest electrodePower cordEarth wireThermal recording paperUser manual• Optional:ECG data lineExternal ink jet printer3G and WIFI

QualificationQualificationQualificationQualification certificatecertificatecertificatecertificate

CCC, CE