HaLFEn Framing channels as compression elements
HSD 13-USHALFEN SHEAR DOWEL SYSTEMS
ConCrete
Many advantages with one result: HALFEN provides safety, reliability and efficiency for you and your customers.
HaLFEn HSD-LD Lockable Dowels.For temporary movement joints in posttensioned slabs.
HALFEN USA Inc. · PO Box 547 · Converse, TX · 78109 Phone: +1 800.423.9140 · www.halfenusa.com · [email protected]
The Lockable Dowel accommodates initial concrete shrinkage and is then locked in position with a mechanical plate and epoxy resin.
2 © 2013 HALFEN · HSD 13-US · www.halfenusa.com
HaLFEn HSD-LD Lockable Dowel
▪ Minimal formwork
▪ Improved site access
▪ Reduced propping time
Read more about the advantages of the HALFEN HSD-LD Lockable Dowels on the pages 18 to 25.
traditional "pour strips"
▪ Additional formwork
▪ Trip hazard
▪ Restricted access
▪ Slabs propped for several weeks
3
table of content
HaLFEn HSD SHEaR DoWEL SYStEMS
© 2013 HALFEN ·HSD 13-US · www.halfenusa.com
HaLFEn HSD Shear Dowel Systems
HaLFEn HSD-LD Lockable Dowels
- Product Range
- Introduction
- Applications
- HSD/HSD-ULTRA design capacities
- Introduction
- Applications
- Product Range
- Performance Data
- Reinforcement Details
- Installation Procedure
4
4-5
6
7-9
10
18
18
19
20-21
22-23
24
25
HaLFEn HSD-ULtRa High Capacity Shear Dowels
- Introduction
- Performance Data
- Installation Procedure
HaLFEn HSD Shear Dowels
HaLFEn HSD-aD acoustic Dowels
- Introduction
- Performance Data
- Introduction
- Performance Data
11
11
12-13
14
15
15
16-17
26
26
27
Public Health Facility
Product Range
HaLFEn HSD SHEaR DoWEL SYStEMS
HaLFEn Shear Dowels
4 © 2013 HALFEN · HSD 13-US · www.halfenusa.com
The HALFEN range of shear dowels provides
solutions for a wide range of applications,
loads, slab depths and joint thicknesses.
Each connector is a two-part assembly com-
prising a sleeve and a dowel component.
The sleeve is nailed to the formwork ensu-
ring subsequent alignment with the dowel.
This alignment is essential for effective
movement. The complete installation proce-
dure is shown on page 14. HALFEN Shear
Dowels are manufactured from stainless
steel to ensure a high degree of corrosion re-
sistance with no requirements for additional
protection.
HaLFEn HSD-ULtRaThe HALFEN HSD-ULTRA is a two-part, high
capacity, shear dowel. The dowel compo-
nent moves longitudinally within the sleeve
to accommodate movement. The connector
is available in seven sizes with design capa-
cities from 5.5 kip to over 120 kip. The load
tables on page 12-13 include slab depths
from 6 1/2 " to 20" and joints up to 2" wide.
The dowel bar is Duplex stainless steel and
all other components are manufactured
from grade 1.4301 (304) stainless steel.
HaLFEn HSD-ULtRa-VThe HALFEN HSD-ULTRA-V, high load Shear
Dowel uses the same dowel component as
the HALFEN HSD-ULTRA, but the cylindrical
sleeve is contained within a rectangular box
section. This sleeve allows lateral movement
or rotation in addition to longitudinal move-
ment. Available sizes, performance data and
material specifications are the same as for
the HSD-ULTRA.
HaLFEn HSDThe HALFEN HSD Shear Dowel is used
where loads are small, but where alignment
is critical. It is available in four sizes.
The dowel component is Duplex stainless
steel.
HALFEN HSD-ULTRA
HALFEN HSD
HALFEN HSD-ULTRA-V
HALFEN HSD-V
HaLFEn HSD-VThe HALFEN HSD-V Shear Dowel uses the
same dowel as the HSD, but the cylindrical
sleeve is contained within a rectangular box
section to allow lateral movement or rotati-
on in addition to longitudinal movement.
Product Range
HaLFEn HSD SHEaR DoWEL SYStEMS
HaLFEn HSD-LD Lockable Dowel*The dowel component is manufactured from
13/16" diameter stainless steel; one end is
threaded with a fixed nut and washer, and
the other features a series of grooves to
accept a Locking Plate. The cylindrical sleeve
which accepts the dowel component is con-
tained within a box-section to allow lateral,
longitudinal, and rotational movement. The
epoxy resin is poured into the L-shaped void
former. This product has a maximum design
shear strength of over 15 kip. See pages
18-25 for full technical details.
HaLFEn HSD-LD-ULtRa Lockable Dowel*The HSD-LD-ULTRA is a high capacity Lockable
Dowel with a design shear strength of up to
30.6 kip. See pages 18-25 for full technical details.
HaLFEn HSD-LD-W Lockable Dowel*The dowel component is manufactured from
13/16" diameter stainless steel, but is shorter
than the HSD-LD dowel. One end of the dowel
is designed to fit into the stainless steel Threa-
ded Anchor cast into the face of the concrete
and the other end features a series of grooves
to accept a Locking Plate. The sleeve compo-
nent is the same as used in the HSD-LD. See
pages 18-25 for full technical details.
HaLFEn HSD-aD acoustic DowelsThe HALFEN HSD-AD Acoustic Dowels are
designed to transfer shear loads and limit
sound transmission across joints in concrete.
The sleeve has Elastomer sound absorbing
material between two stainless steel tubes
and a nail plate for fixing to formwork. The
sound transmission properties are generally
unaffected by either joint width or service
load. Tests in the frequency range of 100 -
3150 Hz have shown a reduction in sound
transmission of 20 dB. When the standard
solid dowel (HSD-AD Type B) was replaced
by an anti-vibration dowel (HSD-AD Type A)
a reduction of 25 dB was recorded.See
pages 26-27 for more technical details.
5© 2013 HALFEN · HSD 13-US · www.halfenusa.com
HALFEN HSD-LDSlab-to-Slab
HALFEN HSD-LD-WSlab-to-Wall
HALFEN HSD-ADacoustic Dowel
Sleeve Component featuring void former supplied with label on nailing plate
Sleeve Component featuring void former supplied with label on nailing plate
Sleeve Component featuring void former supplied with label on nailing plate
Threaded Anchor supplied with a nailing plate
Dowel Component
Dowel Component
Dowel Component
Sound absorbing material
Locking Plate (notches indicate minimum resin depth)
Locking Plate (notches indicate minimum resin depth)
Locking Plate (notches indicate minimum resin depth)
*US Patent No. 8209933
HALFEN-LD-ULTRASlab-to-Slab
6 © 2013 HALFEN · HSD 13-US · www.halfenusa.com
HaLFEn HSD SHEaR DoWEL SYStEMS
Dowelled Joints Keyed Joints
Dowels are used to transfer shear across
construction and movement joints in con-
crete. They are often either cast or drilled
into the concrete. A single row of short
thick dowels provides reasonable shear
transfer but demands additional accuracy
during construction. Skewed installation of
dowels can lead to stress concentrations,
resulting in subsequent spalling of the con-
crete. Where dowels are used across expan-
sion and contraction joints, half the length
of the bar is debonded to allow movement
to take place. Dowelled joints either require
formwork to be drilled for the dowels to
pass through, or concrete to be drilled for
dowels to be resin fixed in one side. At
movement joints, dowels will need to be ac-
curately aligned in both directions to ensure
movement can actually take place, other-
wise cracking is likely to occur. Plain dowels
are not very effective when used across
joints wider than 3/8".
Keyed joints require complicated formwork
to create the tongue and groove. If the joint
is not formed correctly, differential move-
ment can take place. Load is transferred
through the locally reduced section of the
joint which can at times result in cracking.
The two-part assembly of HALFEN Shear Dowels ensures dowel alignment
HALFEN HSD-ULTRA Sleeve Component
HALFEN HSD-ULTRA Dowel Component
In t roduct ion
HaLFEn HSD SHEaR DoWEL SYStEMS
7© 2013 HALFEN · HSD 13-US · www.halfenusa.com
HaLFEn Solutions to Joints
In most cases conventional dowelled or
keyed joints can be replaced by joints in-
corporating HALFEN Shear Dowels. These
connectors are more effective at transferring
load and allowing movement to take place,
easier to fix on site, and can prove to be a
more cost-effective solution.
HALFEN connectors can be used for mo-
vement joints in floor slabs, suspended
slabs, and for replacing double columns and
beams at structural movement joints. Ap-
plications in civil engineering include joints
in bridge parapets, bridge abutments and
diaphragm wall constructions.
traditional solution HaLFEn solution
Double Columns
Dowel Bar
Keyed Joint
Corbel Support
HALFEN HSD-ULTRA
HALFEN HSD-ULTRA
HALFEN HSD-ULTRA
Single Column with HALFEN HSD-ULTRA
Floor Slab
Wall
Slab/wall connection
appl icat ions
Floor-to-floor connection with columns
8 © 2013 HALFEN · HSD 13-US · www.halfenusa.com
HaLFEn HSD SHEaR DoWEL SYStEMSappl icat ions
There are many applications for HALFEN
HSD Shear Dowels in all types of reinforced
concrete constructions ‒ both building and
civil engineering projects.
Ground Floor SlabsMovement joints are usually required to divide
a reinforced concrete ground slab into bays.
HALFEN HSD Shear Dowels are used to trans-
fer shear load from slab to slab and to
prevent differential settlement. Where adjoin-
ing bays are different sizes, movement in two
directions will occur, HALFEN HSD-V Shear
Dowels should be used in this situation.
Suspended Floor SlabsIn suspended slabs, connectors should be
placed at points of contraflecture where
there is little or no bending moment and
maximum shear force.
Structural Movement Joints in FramesA common requirement in framed buildings
is a structural movement joint to isolate one
part of the building from another. Traditi-
onal practice is to provide a line of double
columns. The use of HALFEN Shear Dowels
reduces costs, speeds construction, and
increases the useable floor area.
Beam to Wall or Slab ConnectionsCorbel and half lap joints are a problem
to design and difficult and expensive to
construct. The use of HALFEN HSD Shear
Dowels simplifies design and construction,
producing a better detail.
Post-tensioned Building FramesThe HALFEN range includes Lockable
Dowels which replace pour strips in post-
tensioned concrete frames. See page 18 to
25 for more information.
Building applicat ions
9© 2013 HALFEN · HSD 13-US · www.halfenusa.com
HaLFEn HSD SHEaR DoWEL SYStEMSappl icat ions
Movement Joints in Carriageways HALFEN HSD Shear Dowels are used in car-
riageway joints to transfer high shear loads
caused by traffic loading and for eliminating
differential settlement.
Bridge abutmentsHALFEN HSD Shear Dowels are used vertically
at bridge abutments to fix the bridge deck to
the abutment. In addition to ease of installa-
tion, the use of HALFEN HSD Shear Dowels
allows for the bridge deck to be jacked up for
bearings to be replaced.
Joints in ParapetsThe use of HALFEN Shear Dowels in the
vertical joints in parapets is a simple and cost
effective way of connecting the sections. The
HALFEN HSD-V facilitates significant rotation
at the joint without reducing the horizontal
shear capacity.
Diaphragm Wall/Slab ConnectionsConnecting road slabs to diaphragm walls
can be a difficult and expensive operation.
Forming recesses or using post fixed
dowels into site drilled holes presents many
problems on site. HALFEN HSD Shear
Dowels provide a cost effective solution.
The sleeve components are nailed to
plywood formwork which is rigidly fixed
to the reinforcement cage. After excavation
the plywood is removed to reveal the faces
of the sleeves. The dowel components can
now be inserted ready to support the slab.
Civil Engineering applicat ions
HSD/HSD-ULtRa -Des ign capac i t ies
HaLFEn HSD SHEaR DoWEL SYStEMS
Design capacit ies HaLFEn HSD -ULtRa Shear Dowels
HALFEN HSD-ULTRA/HSD-ULTRA-V design capacities FRd [kip] for various joint widths at a maximum slab thickness in 4000 psi concrete.
HALFEN HSD/HSD-V design capacities FRd [kip] for various joint widths at a maximum slab thickness in 4000 psi concrete.
Joint width
Joint width
1/4 "
1/4"
1/2 "
1/2"
1"
1"
11/2"
11/2"
2"
2"
120
10
12
14
100
8
80
6
60
4
40
2
20
0
0
F Rd
[kip
]F R
d [k
ip]
HSD-ULTRA-52(-V)
HSD-30(-V)
HSD-ULTRA-42(-V)
HSD-25(-V)
HSD-ULTRA-35(-V)
HSD-22(-V)
HSD-ULTRA-30(-V)
HSD-20(-V)
HSD-ULTRA-24(-V)
HSD-ULTRA-22(-V)
HSD-ULTRA-18(-V)14.8 13.7 11.9
7.9
20.514.2
7.6
6.7
5.65.0
6.2
5.4
4.43.9
25.9 24.3 24.718.4
9.2
8.2
6.96.2
30.1
28.3
13.513.0
11.8
10.8
45.643.4
38.7
30.6
64.161.4
55.5
45.9
82.7
78.9
71.3
59.8
87.5
52.2
38.4
25.0
14.811.56.3
6.7
8.2
9.8
115.6112.2
105.2
94.6
13.5
Design capacit ies HaLFEn HSD Shear Dowels
10 © 2013 HALFEN · HSD 13-US · www.halfenusa.com
11
In t roduct ion HSD-ULtRa/HSD-ULtRa -V
HaLFEn HSD-ULtRa SHEaR DoWEL SYStEM
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
The HALFEN HSD-ULTRA is a shear dowel
system for high loads. The steel plates in
the area around the dowel and the sleeve
distribute the load in the concrete and al-
low higher loads than conventional shear
dowels.
HALFEN HSD-ULTRA shear dowels come in
two parts. The set always consists of the do-
wel (HSD-ULTRA-D) and the corresponding
sleeve (HSD-ULTRA-S and HSD-ULTRA-SV,
respectively). The HSD-ULTRA does not
allow any movement perpendicular to the
dowel. The HSD-ULTRA-V allows lateral mo-
vement in one direction. Both, HSD-ULTRA
and HSD-ULTRA-V allow movement in longi-
tudinal direction.
HALFEN HSD-ULTRA-Set HALFEN HSD-ULTRA-Set-V
Dimensions of the dowels and sleeves can
be found on this page. Additional informa-
tion like design capacities and required rein-
forcement can be found on pages 12-13.
Edge Distance and SpacingThe minimum edge distance and spacing of the HALFEN HSD-
ULTRA shear dowels is determined by the depth of slab and is
illustrated in the adjacent drawing.
HSD-ULtRa-D Dowel HSD-ULtRa-S Sleeve HSD-ULtRa-SV Sleeve
Length Length LengthWidth Width Width
Maximal lateral movement
Height Height Height
Projection
Diameter
1/2" 1/2"1/2" 1/2"
H
min. 0.75 H min. 1.50 H
HaLFEn HSD-ULtRa and HSD-ULtRa-V ‒ Dimensions
Dowel HSD-ULtRa-D Sleeve HSD-ULtRa-S Sleeve HSD-ULtRa-SV
Diameter [Inch]
Length [Inch]
Projection [Inch]
Height [Inch]
Width [Inch]
Length [Inch]
Height [Inch]
Width [Inch]
Length [Inch]
Height [Inch]
Width [Inch]
lat. movement
[Inch]
HSD-ULtRa18(-V) 11/16 10 5/8 5 7/8 3 2 3/4 6 1/8 3 2 3/4 6 3/4 3 3 7/8 1
HSD-ULtRa22(-V) 7/8 12 1/4 6 1/4 3 3/4 3 1/2 6 1/2 3 3/4 3 1/2 6 7/8 3 3/4 4 1/27/8
HSD-ULtRa24(-V) 15/16 13 6 3/4 4 3/8 3 7/8 6 7/8 4 3/8 3 7/8 7 1/8 4 3/8 4 3/47/8
HSD-ULtRa30(-V) 1 3/16 14 3/8 7 1/4 5 1/2 4 1/2 7 1/2 5 1/2 4 1/2 8 1/4 5 1/2 6 3/8 1 5/8
HSD-ULtRa35(-V) 1 3/8 16 1/2 8 1/4 6 1/4 5 1/4 8 1/2 6 1/4 5 1/4 9 1/4 6 1/4 6 3/4 1 1/4
HSD-ULtRa42(-V) 1 5/8 18 1/2 9 7 1/8 6 7/8 9 5/8 7 1/8 6 7/8 9 5/8 7 1/8 8 1 7/8
HSD-ULtRa52(-V) 2 1/16 22 1/2 11 8 5/8 8 1/4 11 5/8 8 5/8 8 1/4 11 5/8 8 5/8 9 5/8 1 1/2
12
HaLFEn HSD-ULtRa SHEaR DoWEL SYStEMPer formance data HSD-ULtRa 18, 22, 24 / HSD-ULtRa -18V, 22V, 24V
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
Local reinforcement is required around each
connector to guarantee that the forces are
transferred between the connectors and the
concrete. Correct detailing in accordance
with appropriate design codes and the
recommendations provided here will ensure
HALFEN HSD-ULTRA and HSD-ULTRA-V
shear dowels attain their full capacity. The
tables below show proposals for the type
and spacing of the main reinforcement,
together with details of reinforcement
above and below the shear dowels.
Reinforcement details
Main reinforcement each side of shear dowel
Longitudinal reinforcement above shear dowel
Longitudinal reinforcement below shear dowel
Longitudinal reinforcement above shear dowel
Longitudinal reinforcement below shear dowel
Main reinforcement each side of shear dowel
Design capacities FRd [kip] for various joint widths [Inch] in 3000/4000 psi concrete
Dowel Slab thickness
[Inch]1/4
1/2 1 1 1/2 2
6 1/2 7.9 9.4 7.9 9.0 7.9 8.1 7.9 7.9 6.3 6.3
7 8.7 10.6 8.3 10.1 7.9 9.2 7.9 7.9 6.3 6.3
7 1/2 9.9 11.9 9.6 11.5 9.0 10.3 7.9 7.9 6.3 6.3
8 10.4 12.6 10.1 12.1 10.2 11.0 7.9 7.9 6.3 6.3
9 11.2 13.5 10.7 12.8 10.8 11.7 7.9 7.9 6.3 6.3
10 11.9 14.2 11.9 13.7 11.9 11.9 7.9 7.9 6.3 6.3
11 13.1 14.8 12.3 13.7 11.9 11.9 7.9 7.9 6.3 6.3
7 1/2 13.5 16.4 13.2 16.0 12.2 14.8 11.7 14.2 11.5 11.5
8 15.7 20.2 15.8 19.3 15.7 18.2 14.2 14.2 11.5 11.5
9 18.1 21.8 18.1 21.1 18.0 19.8 14.2 14.2 11.5 11.5
10 20.6 23.4 20.7 22.9 20.2 20.5 14.2 14.2 11.5 11.5
11 23.9 25.2 23.8 24.3 20.2 20.5 14.2 14.2 11.5 11.5
12 25.2 25.9 23.8 24.3 20.2 20.5 14.2 14.2 11.5 11.5
8 16.3 19.8 16.0 19.3 15.1 18.2 14.8 15.3 14.8 14.8
9 19.4 23.6 19.1 23.2 19.1 21.8 18.4 18.4 14.8 14.8
10 25.0 27.9 25.0 27.2 24.5 24.7 18.4 18.4 14.8 14.8
11 28.8 29.9 27.7 28.3 24.5 24.7 18.4 18.4 14.8 14.8
12 29.3 30.1 27.7 28.3 24.5 24.7 18.4 18.4 14.8 14.8
Load bearing capacities
HSD-ULTRA-18(-V)
HSD-ULTRA-22(-V)
HSD-ULTRA-24(-V)
e2 e2 e2 e2
Local reinforcement around the dowels in 3000/4000 psi concrete
Dowel Main reinforcement [total per shear dowel]
Longitudinal bars top and bottom
U-bars each side of the dowel distance e1 [inches] distance e2 [inches]
(2) No. 4 (2) No. 4 1 1/4 1 1/4 2 2 (2) No. 4 (2) No. 4
(4) No. 4 (4) No. 4 1 1/4 1 1/4 1 1/4 2 (2) No. 4 (2) No. 4
(5) No. 4 (4) No. 4 1 1/4 1 1/4 1 1/2 1 1/4 (2) No. 4 (2) No. 4
HSD-ULTRA-18(-V)
HSD-ULTRA-22(-V)
HSD-ULTRA-24(-V)
Minimum longitudinal bars are based on minimum dowel centres (1.5 * hmin). If spacing greater than this is adopted, the longitudinal bars are to be designed assuming slab edge acts as a beam spanning between the dowels.
e1e1
13
Per formance data HSD-ULtRa 30, 35, 42, 52 / HSD-ULtRa -30V, 35V, 42V, 52V
HaLFEn HSD-ULtRa SHEaR DoWEL SYStEM
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
Reinforcement details
Longitudinal reinforcement above shear dowel
Main reinforcement each side of the shear dowel
Longitudinal reinforcement below shear dowel
Design capacities FRd [kip] for various joint widths [Inch] in 3000/4000 psi concrete
Dowel Slab thickness
[Inch]1/4
1/2 1 1 1/2 2
10 30.0 33.9 30.0 33.9 29.7 33.5 29.7 30.1 25.0 25.0
11 32.3 36.6 32.3 36.6 32.4 36.6 30.6 30.6 25.0 25.0
12 35.2 39.8 35.3 39.8 35.3 38.7 30.6 30.6 25.0 25.0
13 38.8 42.7 38.9 42.7 38.0 38.7 30.6 30.6 25.0 25.0
14 44.3 45.6 42.3 43.4 38.0 38.7 30.6 30.6 25.0 25.0
12 50.4 57.1 50.4 57.1 50.4 55.5 45.6 45.9 38.4 38.4
14 62.3 64.1 60.1 61.4 54.6 55.5 45.6 45.9 38.4 38.4
14 66.1 74.0 66.1 74.0 66.1 71.3 59.8 59.8 52.2 52.2
16 82.7 82.7 78.9 78.9 71.3 71.3 59.8 59.8 52.2 52.2
16 87.9 99.6 87.9 99.6 87.9 99.6 87.9 94.6 86.3 87.5
18 103.8 111.5 103.8 111.5 102.4 105.2 92.9 94.6 86.3 87.5
20 111.4 115.6 108.5 112.2 102.4 105.2 92.9 94.6 86.3 87.5
Load bearing capacities
HSD-ULTRA-30(-V)
HSD-ULTRA-35(-V)
HSD-ULTRA-42(-V)
HSD-ULTRA-52(-V)
Local reinforcement around the dowels in 3000/4000 psi concrete
Dowel Main reinforcement [total per shear dowel]
Longitudinal bars top and bottom
U-bars each side of the dowel distance e1 [Inches] distance e2 [Inches]
(5) No. 4 (5) No. 4 1 1/4 1 1/4 1 1/4 1 1/4 (3) No. 4 (3) No. 4
(5) No. 5 (5) No. 5 1 1/4 1 1/2 1 1/2 2 (2) No. 5 (2) No. 5
(6) No. 5 (5) No. 5 1 1/4 1 1/4 1 1/2 1 1/2 (3) No. 5 (3) No. 5
(8) No. 5 (7) No. 5 1 1/4 1 1/4 1 1/2 1 1/2 (4) No. 5 (4) No. 5
HSD-ULTRA-30(-V)
HSD-ULTRA-35(-V)
HSD-ULTRA-42(-V)
HSD-ULTRA-52(-V)
e2
e1e1
e2
All values in the tables on page 12 and 13 are design load capacities (LRFD) and have to be compared to factored loads.
Minimum longitudinal bars are based on minimum dowel centres (1.5 * hmin). If spacing greater than this is adopted, the longitudinal bars are to be designed assuming slab edge acts as a beam spanning between the dowels.
14
HaLFEn HSD-ULtRa SHEaR DoWEL SYStEMIns ta l la t ion Procedure
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
Installat ion Procedure
The two-part assembly of all HALFEN Shear Dowels removes the need for drilling formwork on site, supporting dowel bars and fitting debond-ing sleeves and end caps. The installation is a fast and accurate process.
Nail the sleeve component to the formwork ensuring that the sleeve is correctly orientated for the direction of the load. Check that the minimum spacing and edge distances are not exceeded. The label prevents debris from enter- ing into the sleeve aperture and should not be removed at this stage.
When the concrete has achieved sufficient strength, strike the shuttering. Peel off or puncture the label to reveal the hole for the do-wel. Where HSD-V or HSD-ULTRA-V are being used, the label should only be punctured enough to allow the dowel into the cylindrical sleeve.
Fix the local reinforcement in position around the dowel component together with any other reinforcement that is required, ensuring that the correct cover to the reinforcement is maintained. Pour the concrete to complete the installation of the shear connector.
Position the compressible joint filler of the appropriate width for applications where movement is expected between the two sections of concrete.
Notes: (i) Although installation is shown for HALFEN HSD-ULTRA, the procedure is the same for all HALFEN HSD Shear Dowels.
Push the dowel component through the joint filler (if applicable) until it is fully located in the sleeve component. It may be necessary to tap the dowel component to overcome the dimple which pinch holds the dowel in the sleeve and prevents dis-location when the concrete is vibrated.
Fix the local reinforcement in position around the sleeve component together with any other reinforce-ment that is required, ensuring that the correct cover to the reinforcement is maintained. Pour the con-crete to complete the installation of the sleeve component.
HSD and HSD-ULTRA Shear Dowels normally transfer vertical loads across a joint. The face marked ‘Top’ on both the sleeve and the dowel should be uppermost. For applications where the load is not vertical, the face marked ‘Top’ will need to be in the same direction as the load.
(ii) Where deep concrete pours are proposed, the installation will require further consideration. More robust fixing of the sleeve and dowel com-ponents will be necessary, to avoid displacement during pouring of the concrete.
3
6
1
4
2
5
Direction of load
15
In t roduct ion HSD/HSD-V
HaLFEn HSD SHEaR DoWEL SYStEM
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
The HALFEN HSD is a shear dowel system
for applications with smaller loads where
the alignment of the dowels is critical.
HALFEN HSD Shear Dowels come in two
parts. The set always consists of the dowel
(HSD-D) and the corresponding sleeve
(HSD-S and HSD-SV) respectively. The HSD
does not allow any movement perpendicular
to the dowel. The HSD-V allows lateral
movement in one direction. Both, HSD and
HSD-V allow movement in longitudinal
direction. Dimensions of the dowels and
sleeves can be found on this page. Additio-
nal information such as design capacities and
required reinforcement can be found on page
16 and 17.
Length
* Different dowel length are available on request
Dowel Diameter
Internal Diameter Internal Diameter
Maximum lateral movement
widthwidth
heig
ht
Sleeve Length Sleeve Length3"
HSD-D Dowel Component HSD-S Sleeve Component HSD-SV Sleeve Component
HaLFEn HSD HaLFEn HSD-V
HaLFEn HSD- and HSD-V ‒ Dimensions
Dowel HSD-D Sleeve HSD-S Sleeve HSD-SV
Diameter [Inch]
Length [Inch]
Length [Inch]
Height [Inch]
Width [Inch]
Length [Inch]
Height [Inch]
Width [Inch]
lat. movement [Inch]
HSD 20(-V) 13/16 11 3/4 * 6 3/4 3 3 6 3/4 3 3 3/4
HSD 22(-V) 7/8 11 3/4 * 6 3/4 3 3 6 3/4 3 3 3/4
HSD 25(-V) 1 11 3/4 * 6 3/4 3 3 6 3/4 3 3 5/8
HSD 30(-V) 1 3/16 13 3/4 * 7 5/8 3 7/8 3 7/8 7 5/8 3 7/8 4 3/8 1 5/8
16
HaLFEn HSD SHEaR DoWEL SYStEMPer formance data HSD 20, 22, 25, 30 / HSD-20V, 22V, 25V, 30V
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
Design capacities FRd [kip] for various joint widths [Inch] in 3000/4000 psi concrete
Dowel Slab thickness
[Inch]1/4
1/2 1 1 1/2 2
7 4.9 5.6 4.9 5.6 4.9 5.4 4.4 4.4 3.9 3.9
7 1/2 5.1 5.8 5.1 5.8 5.1 5.4 4.4 4.4 3.9 3.9
8 6.7 6.7 6.2 6.2 5.4 5.4 4.4 4.4 3.9 3.9
9 6.7 6.7 6.2 6.2 5.4 5.4 4.4 4.4 3.9 3.9
10 6.7 6.7 6.2 6.2 5.4 5.4 4.4 4.4 3.9 3.9
7 5.5 6.3 5.5 6.3 5.5 6.3 5.5 5.6 5.0 5.0
7 1/2 5.7 6.5 5.7 6.5 5.7 6.5 5.6 5.6 5.0 5.0
8 7.4 7.8 7.4 7.6 6.7 6.7 5.6 5.6 5.0 5.0
9 8.2 8.2 7.6 7.6 6.7 6.7 5.6 5.6 5.0 5.0
10 8.2 8.2 7.6 7.6 6.7 6.7 5.6 5.6 5.0 5.0
8 7.0 7.9 7.0 7.9 7.0 7.9 6.9 6.9 6.2 6.2
9 8.8 9.3 8.8 9.2 8.2 8.2 6.9 6.9 6.2 6.2
10 9.8 9.8 9.2 9.2 8.2 8.2 6.9 6.9 6.2 6.2
11 9.8 9.8 9.2 9.2 8.2 8.2 6.9 6.9 6.2 6.2
12 9.8 9.8 9.2 9.2 8.2 8.2 6.9 6.9 6.2 6.2
8 8.0 9.1 8.0 9.1 8.0 9.1 8.0 9.1 8.0 9.1
9 9.4 10.6 9.4 10.6 9.4 10.6 9.4 10.6 9.4 10.6
10 10.9 12.3 10.9 12.3 10.9 12.3 10.9 11.8 10.8 10.8
11 11.6 13.5 11.6 13.5 11.6 13.0 11.6 11.8 10.8 10.8
12 11.6 13.5 11.6 13.5 11.6 13.0 11.6 11.8 10.8 10.8
Load bearing capacities
Edge Distances and SpacingThe minimum edge distance and spacing
of the HALFEN HSD shear dowels is
determined by the depth of the slab
and illustrated in the adjacent drawing. min. 1.50 Hmin. 0.75 H
H
HSD-20(-V)
HSD-22(-V)
HSD-25(-V)
HSD-30(-V)
All values in the table above are design load capacities (LRFD) and have to be compared to factored loads.
17
Per formance data HSD 20,22, 25, 30 / HSD-20V, 22V, 25V, 30V
HaLFEn HSD SHEaR DoWEL SYStEM
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
Reinforcement details
Local reinforcement is required around each
connector to guarantee that the forces are
transferred between the connectors and the
concrete. Correct detailing in accordance
with appropriate design codes and the
recommendations provided here will ensure
HALFEN HSD and HSD-V shear dowels
attain their full capacity. The tables below
show proposals for the type and spacing of
the main reinforcement, together with de-
tails of reinforcement above and below the
shear dowels.
The minimum longitudinal bars are based on a dowel distance of 1.5 times the slab thickness h. If the spacing is greater than this, the
longitudinal bars are to be designed assuming the slab edge acts as a beam spanning between the dowels.
Design capacities FRd [kip] for various joint widths [Inch] in 3000/4000 psi concrete
Dowel Main reinforcement [total per shear dowel]
Longitudinal bars top and bottom
U-bars each side of the dowel distance e1 [Inches] distance e2 [Inches]
(2) No. 3 (2) No. 3 1 3/4 2 1 3/4 2 (2) No. 3 (2) No. 3
(2) No. 4 (2) No. 4 2 2 2 2 (2) No. 3 (2) No. 3
(2) No. 4 (2) No. 4 1 1/2 2 1 1/2 2 (2) No. 3 (2) No. 3
(2) No. 5 (2) No. 5 2 1/4 2 1/4 2 1/4 2 1/4 (2) No. 3 (2) No. 3
HSD-20(-V)
HSD-22(-V)
HSD-25(-V)
HSD-30(-V)
Main reinforcement each side of shear dowel
Longitudinal reinforcement
above shear dowel
Longitudinal reinforcement
below shear dowel
Longitudinal reinforcement
above shear dowel
Longitudinal reinforcement
below shear dowel
Main reinforcement each side of shear dowel
e2 e2e1 e1 e2 e2
18
HaLFEn HSD-LD LoCKaBLE DoWEL SYStEMIntroduct ion HSD-LD
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
Lockable DowelsHALFEN HSD-LD Lockable Dowels have
been designed for use at temporary move-
ment joints, most commonly found in post-
tensioned concrete frames. These dowels
allow initial shrinkage of the concrete to
take place and are then locked in position
with a mechanical plate and a controlled
amount of epoxy resin. The locked dowels
continue to transfer shear, but prevent
further movement taking place.
advantagesThe use of HALFEN HSD Lockable Dowels
can save a significant amount of time and
materials over other construction methods.
Concrete shrinkage has traditionally been
accommodated by leaving gaps in the slabs
called ‘pour strips’ or ‘closure strips’. These
strips are filled once movement has stabi-
lized, however until they are filled the slabs
must be propped, restricting site access and
delaying site progress. Gaps in the slab also
create a trip hazard for site workers, require
additional formwork and can leave the soffit
face marked. Lockable Dowels improve site
access, minimize formwork requirements,
and accelerate the rate of construction.
With a Lockable Dowel, there is less requi-
rement for the slabs to be propped or a
support corbel to be constructed, as shear
load is transferred by the dowel. The time
saved by early removal of slab props can
be significant.
In addition, engineers have found the
HALFEN HSD Lockable Dowel to be the
preferred design solution for pin-ended
joints. Although it is customary for practical
reasons to use U-bars or other rebar
continuity systems at these connections,
these options do not truly act as hinges
and so rotation of the slab under load can
induce cracking at the wall-to-slab interface
with potential integrity issues.
The Lockable Dowel is closer to a true
pin-ended joint and, being manufactured
from stainless steel, provides additional
corrosion protection over systems using
carbon steel reinforcement. The design
capacities shown on page 24 are backed
by independent test data and the unique
void former allows inspection of the
dowel before the joint is locked. Standard
HALFEN systems are available for use at
slab joints and retaining/core walls, requir-
ing permanent movement.
Pour Strips restrict site access, cause a trip hazard and delay progress on site
19
appl icat ions
HaLFEn HSD-LD LoCKaBLE DoWEL SYStEM
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
applicationsIn most cases, HALFEN Lockable Dowels
can be used to replace pour strips at tem-
porary movement joints in post-tensioned
concrete structures. Standard HALFEN sys-
tems are available for use at slab joints and
retaining/core walls, requiring permanent
movement.
Pour strip in slab
Pour strip at wall-to-slab junction
▪ Restricted access
▪ Slabs propped for several weeks
Slab-to-WallTraditional solution HALFEN solution
Slab-to-SlabTraditional solution HALFEN solution
HALFEN HSD-LD-W Lockable Wall Dowel
HALFEN HSD-LD Lockable Dowel
▪ Minimal formwork
▪ Improved site access
▪ Reduced propping time
▪ additional formwork
▪ trip hazard
▪ Restricted access
▪ Slabs propped for several weeks
▪ Improved site access
▪ Reduced propping time
20
HaLFEn HSD-LD LoCKaBLE DoWEL SYStEMProduct Range
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
HALFEN HSD-LD Lockable Dowels allow in-
itial shrinkage of the concrete to take place
and then, after a pre-determined time peri-
od (generally 28-120 days), the dowels are
locked in position with a mechanical plate
and a controlled amount of epoxy resin. The
range comprises three products; HSD-LD 30
Lockable Dowel, HSD-LD-ULTRA 30 Lock-
able High Capacity Dowel, and HSD-LD-W
Lockable Wall Dowel.
HSD-LD 30* Lockable DowelThe dowel component is manufactured from
1 3/16 " diameter stainless steel; one end is
threaded with a fixed nut and washer, and
the other features a series of grooves to
accept the Locking Plate. The cylindrical
sleeve which accepts the dowel component
is contained within a box-section to allow
lateral, longitudinal, and rotational move-
ment. The epoxy resin is poured into the
L-shaped void former. This product has a
maximum design strength of over 15 kip.
See pages 22 to 24 for full technical details.
Reinforcement around HSD-LD-S 30 Sleeves HSD-LD-ULTRA-S 30 Sleeve nailed to formwork
Range of Lockable Dowels
Slab - to -Slab Lockable Dowels
HSD-LD-ULtRa 30* Lockable High Capacity DowelThe HSD-LD-ULTRA 30 is a high load Lock-
able Dowel with a design capacity of up to
30.6 kip.
* US Patent No. 8209933
Locking Plate (notches indicate minimum resin depth)
Locking Plate (notches indicate minimum resin depth)
HALFEN HSD-LD-ULTRA-S 30 Sleeve Component featuring void former and lid supplied with label on nailing plate
HALFEN HSD-LD-S 30Sleeve Component featuring void former and lid supplied with label on nailing plate
HALFEN HSD-LD-D 30 Dowel Component
HALFEN HSD-LD-ULTRA-D 30 Dowel Component
grooves for adjustable locking position
HaLFEn HSD-LD 30 for Slab-to-Slab connections
HaLFEn HSD-LD-ULtRa 30 for Slab-to-Slab connections
Two-part Epoxy Resin
Example Specification ClauseDelete/Amend blue text as appropriate
<HALFEN HSD-LD 30 or HALFEN HSD-LD-ULTRA 30> lockable shear load connector comprising dowel, sleeve and locking components to
be installed at the temporary movement joint between two slabs. Product to be positioned at <insert centers> inch horizontal centers at
<the center line of the slab or XXX inch from the top of the slab>. The dowel is to be locked in position after <insert time period> using
the locking plate and resin supplied. System should be installed in accordance with HALFEN’s instructions and engineer’s drawings.
grooves for adjustable locking position
21
Product Range
HaLFEn HSD-LD LoCKaBLE DoWEL SYStEM
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
* US Patent No. 8209933
HSD-LD-W-D 30* Lockable Wall DowelThe HSD-LD-W-D 30 dowel component is
also manufactured from 1 3/16 " diameter
stainless steel, but is shorter than the HSD-
HSD-LD-D 30 dowel. One end of the dowel
is designed to screw into the stainless steel
HALFEN HSD-LD-W Anchor 40 cast into
the face of the concrete and the other end
features a series of grooves to accept the
Locking Plate. The sleeve component is the
same as used in the HALFEN HSD-LD 30.
See pages 22 to 24 for full technical details.
Epoxy ResinEach dowel is locked after a pre-determined
time period (generally 28-120 days) with a
high quality, two-part epoxy resin. The resin
is mixed and poured into the L-shaped void
former. Each dowel requires 1.5 liters of re-
sin which is supplied in a single can for each
dowel to control the quantity.
Example Specification ClauseDelete/Amend blue text as appropriate
HALFEN HSD-LD-W 30 Lockable Wall
Dowel comprising dowel, sleeve, threaded
anchor and locking components to be
installed at the temporary movement joint
between slab and wall. Product to be po-
sitioned at <insert centers> inch horizontal
centers at <the center line of the slab or
XXX inch from the top of the slab>. The
dowel is to be locked in position after
<insert time period> using the locking
plate and resin supplied. System should
be installed in accordance with HALFEN’s
instructions and engineer’s drawings.
Sleeve pushed over dowel component at core wall
Void formers shown at Slab-to-Wall joint Slab-to-Wall Application
Slab - to -Wall Lockable DowelLocking Plate (notches indicate minimum resin depth)
HSD-LD-S 30 Sleeve Component featuring void former supplied and lid with label on nailing plate
HSD-LD-W-D 30 Dowel Component
HALFEN HSD-LD-W Anchor 40 Threaded Anchor supplied with a nailing plate
HaLFEn HSD-LD-W 30 for Slab-to-Wall
Two-part Epoxy Resin
grooves for adjustable locking position
22
HaLFEn HSD-LD LoCKaBLE DoWEL SYStEMPer formance Data
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
Performance Data
MovementVertical load transfer between slabs Locked
Vertical load transfer between slabs
Load transfer between slabs
Slab thickness Design Strength Longitudinal Load
[kip]
Vertical Design Strength [kip] for Various Design Joint Widths in 4000 psi Concrete
1/4 " 1/2 " 3/4 " 1 " 11/4 " 11/2 " 2 "
6 1/4 " 10.0 2.7 2.7 2.7 2.7 2.7 2.7 2.7
6 1/2 " 10.0 3.4 3.4 3.4 3.4 3.4 3.4 3.4
7 " 14.6 5.1 5.1 5.1 5.1 5.1 5.1 5.1
7 1/2 " 14.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6
8 " 18.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0
8 5/8 " 22.5 12.0 12.0 12.0 12.0 12.0 12.0 10.8
9 " 22.5 13.0 13.0 13.0 12.8 12.2 11.8 10.8
10 " 22.5 14.0 14.0 14.0 14.0 13.6 13.0 12.4
11 " and above 22.5 15.7 15.7 14.9 14.2 13.6 13.0 12.5
Slab thickness Design Strength Longitudinal Load
[kip]
Vertical Design Strength [kip] for Various Design Joint Widths in 4000 psi Concrete
1/4 " 1/2 " 3/4 " 1 " 11/4 " 11/2 " 2 "
6 1/4 " 10.0 2.7 2.7 2.7 2.7 2.7 2.7 2.7
6 1/2 " 10.0 3.4 3.4 3.4 3.4 3.4 3.4 3.4
7 " 14.6 5.1 5.1 5.1 5.1 5.1 5.1 5.1
7 1/2 " 14.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6
8 " 18.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0
8 5/8 " 18.0 12.0 12.0 12.0 12.0 12.0 12.0 10.8
9 " 18.0 13.0 13.0 13.0 12.8 12.2 11.8 10.8
10 " 18.0 14.0 14.0 14.0 14.0 13.6 13.0 12.4
11 " and above 18.0 15.7 15.7 14.9 14.2 13.6 13.0 12.5
Slab thickness Design Strength Longitudinal Load
[kip]
Vertical Design Strength [kip] for Various Design Joint Widths in 4000 psi Concrete
1/4 " 1/2 " 3/4 " 1 " 11/4 " 11/2 " 2 "
9 1/2 " and above 22.5 30.6 30.6 30.6 30.6 30.6 30.6 30.6
HSD-LD 30 Lockable Dowel [slab-to-slab]
HSD-LD-W 30 Lockable Dowel [slab-to-wall]
HSD-LD-ULtRa 30 Lockable Dowel [slab-to-slab]
All values in the table above are design load capacities (LRFD) and have to be compared to factored loads.
23
Per formance Data
HaLFEn HSD SHEaR DoWEL SYStEM
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
DimensionsHSD-LD 30 Lockable Shear Dowel Components:HSD-LD-D 30 Dowel
HSD-LD-ULtRa 30 Lockable Shear Dowel Components:HSD-LD-ULtRa-D 30 Dowel
HSD-LD-W 30 Lockable Wall Dowel Components:HSD-LD-W-anchor 40 threaded anchor
HSD-LD-S 30 Sleeve
HSD-LD-ULtRa-S 30 Sleeve
HSD-LD-S 30 SleeveHSD-LD-W-D 30 wall dowel
5 1/2 "
4 1/2 " 19 " 11 "
9 1/2 "
10 1/2 "
10 1/2 "
1 3/16 "
1 3/16 "
4 1/16 "
3 5/8 "
1 5/8 "
6 "
61/2 "
61/2 "
5 1/2 "
4"
41/2 "
7 "
Max. 11/2 " lateral movement
Max. 11/2 " lateral movement
h
min. 1.5h0.75h
18 "
13/16 " 61/2 "
4"
41/2 "
Max. 11/2 " lateral movement
91/2 "
11/4 "Internal Diameter
11/4 "Internal Diameter
11/4 "Internal Diameter
1/4 "1/4 "
Edge Distance and SpacingsFor connectors working at or near their maximum capacity, the minimum spacing should be 1.5 times the slab thickness. Where the allowable load of the connector could be used in a thinner slab, a spacing of 1.5 times the thinner slab thickness can be used. The minimum end distance is always 0.5 times the spacing.
M 30 x 3.5 mm
71/2 " min. 15" min.
10" min.
HSD-LD-ULTRA 30 Minimum Edge Distance and Spacings
1.5h0.75h
HSD-LD-W 30 Minimum Edge Distance and Spacings. h = depth of adjoining slabHSD-LD 30 Minimum Edge Distance and Spacings
HaLFEn HSD-LD 30 Lockable Dowel sample calculationSlab thickness = 10 "
Joint width = 3/4 "
Concrete strength = 4,000 psi
Characteristic permanent action (dead load) = 3.0 kip/ft factor = 1.2
Characteristic variable action (imposed load) = 3.5 kip/ft factor = 1.6
Factored load = 3.0 x 1.2 + 3.5 x 1.6 = 9.2 kip/ft
Design strength = 14 kip (10 " slab 3/4 " joint)
Therefore centers for vertical load = 14 / 9.2 = 1.52 ft use 18" centers
Once it is locked, this dowel will provide a design longitudinal capacity of 22.5 kip / 1.5 ft = 15 kip/ft.
24
HaLFEn HSD-LD LoCKaBLE DoWEL SYStEMReinforcement Deta i l s
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
Reinforcement DetailsLocal reinforcement is required around each HALFEN Lockable Dowel to guarantee that the forces are transferred between the connectors
and the concrete. Correct detailing in accordance with appropriate design codes and the recommendations provided here will ensure the
dowels attain their full capacity. The tables show the main reinforcement required, together with details of reinforcement above and below
the connectors. Although only the sleeve components are illustrated, the same reinforcement is required around the dowel component.
threaded anchorReinforcement around the HALFEN Threaded Anchor should be
a minimum #4, installed at maximum 8" vertical and horizontal
centers.
HSD-LD 30
HSD-LD-ULtRa 30
Longitudinal reinforcement above dowels
Longitudinal reinforcement above dowels
Longitudinal reinforcement above dowels
Longitudinal reinforcement above dowels
Longitudinal reinforcement below dowels
Longitudinal reinforcement below dowels
Longitudinal reinforcement below dowels
Longitudinal reinforcement below dowels
Main reinforcement each side of connector
Main reinforcement each side of connector
Main reinforcement each side of connector
Main reinforcement each side of connector
Dowel slab thickness reinforcement on each side
HSD-LD 306 1/4 " and 6 1/2 " (1) No. 4
7 " and above (2) No. 4
HSD-LD-ULTRA 30 9 1/2 " and above (3) No. 4
Lockable Dowel Longitudinal bars top and bottom
HSD-LD 30 (2) No. 3
HSD-LD-ULTRA 30 (3) No. 4
Main Reinforcement
Longitudinal Reinforcement
HSD-LD-S 30 with required reinforcement
HSD-LD-ULtRa-S 30 with required reinforcement
HSD-LD-W-anchor 40 with required reinforcement
2" 2"2" 2"2" 2"
2" 2"2" 2"
25
Ins ta l la t ion Procedure HSD-LD 30, HSD-LD-ULtRa 30 and HSD-LD-W 30
HaLFEn HSD-LD LoCKaBLE DoWEL SYStEM
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
Although installation is shown for the HSD-LD 30, the procedure is the same for the HLD-LD-ULTRA 30.
Nail the sleeve to the formwork either central in the slab or for slab depths over 12" so the top of the void former is level with the top of the slab. Do not remove the label over the nailing plate as this prevents ingress of concrete into the sleeve. Place the local reinforcement, as specified on engineer’s drawings.
After a predetermined time period (generally 28-120 days), when movement between the slabs has stabilized and the joint between the slabs has been filled, the dowel is ready to be locked. Fit the Locking Plate on a groove in the center of the void former. The fan-shaped Locking Plate allows the dowel to be locked in any position.
Nail the threaded anchor to the formwork so the dowel will be central in the adjoining slab or within 6" of the top of slabs over 12". Place the local reinforcement as specified on engineer’s drawings and cast the concrete.
Pour the concrete, and when the required strength is attained, remove the formwork. Punc-ture the label to reveal the cylindrical sleeve only and insert the dowel until it is approximately 3/4 " from the back of the void former.
Mix the two-part epoxy resin and pour into the void former. It is essential the resin flows along the stainless steel box section towards the joint and reaches the notches on the locking plate, which indicate minimum resin depth. Joint must be filled before resin is installed.
When concrete reaches sufficient strength, remove the formwork and remove nailing plate. Screw the dowel into the anchor.
Place the local reinforcement around the dowel component and pour the concrete.
After 24 hours the void former can be filled with cementitious material, level with the top of the slab, to complete the installation. The locked dowel continues to transfer vertical load between the slabs, but movement can no longer take place.
Puncture the label of the sleeve to reveal the cylindrical sleeve only. Push the sleeve over the dowel until it is flush with the concrete. Tie sleeve to reinforcement and pour concrete. See steps 4 to 6 above to complete installation.
notes: Where deep concrete pours are proposed, the installation will require further consideration. More robust anchoring of the sleeve
and dowel components will be necessary, to avoid displacement during casting of the concrete.
Installat ion HSD - LD 30 and HSD - LD -ULtRa 30 (slab - to - slab)
Installat ion HSD - LD 30 (slab - to -wall)
1
4
1
2 3
6
3
5
2
26
HaLFEn HSD- aD aCoUStIC DoWEL SYStEMIntroduct ion
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
HaLFEn HSD-aD acoustic DowelHALFEN HSD-AD is a high load capacity
shear stainless steel shear connector: it
enables acoustic as well as thermal insula-
tion. Typical applications include shear load
transfer at joints subjected to impact noises
(stairway ramps, landings, corridors, loggias
etc.).
HALFEN HSD-AD Acoustic Dowels replace
standard corbels and bearings. They are
easy to use and can be installed for cast-in-
place concrete wall and landing construction
as well as with pre-cast concrete elements
and masonry walls.
HALFEN HSD-AD Acoustic Dowels are safe,
provide optimum acoustic insulation proper-
ties, and long durability.
HSD-AD-S-AB
Protection Tube Connector ReinforcementHaLFEn HSD-aD-D-a5/8 " diameter B500B reinforcement sealed
using Sika Grout 212 mortar within a V4A,
1 3/8 " protection tube.
Suitable for joint widths up to 2".
HaLFEn HSD-aD-D-BHigh ductility shear dowel.1 3/8 " diameter
solid dowel, grade 1.4462
Suitable for joint widths up to 4".
StaISIL overview
HaLFEn HSD-aD-D-C Dowel ComponentSolid stainless steel high load capacity
shear dowel.13/8 " diameter, steel grade
1.4462 with elastomeric compound
F8042 and V4A external shell.
Suitable for joint widths up to 4".
HaLFEn HSD-aD-S-C Sleeve ComponentSleeve in grade 1.4301 steel.
HALFEN HSD-AD Acoustic Dowels are
available as Type A, which is a diameter 5/8″ reinforcement bar sealed in grout with
ASTM 316 protection tube around it and
high ductility dowels Type B, which is a solid
diameter 1 3/8″ stainless steel dowel. Both
dowels can be used in combination with the
HALFEN HSD-AD Sleeve.
HaLFEn HSD- aD acous t ic Dowels type a , B and C
HSD-AD-D-A/B Dowel Component
HSD-AD-D-C Dowel Component
HSD-AD-S-AB Sleeve Component
HSD-AD-S-C Sleeve Component
27
HaLFEn HSD- aD aCoUStIC DoWEL SYStEM
© 2013 HALFEN · HSD 13-US · www.halfenusa.com
Edge Distances and SpacingThe edge distances and connector spacing
required, as shown in the drawing on the
left, are defined by the slab thickness.
HaLFEn HSD -aD acoustic Dowels type a and B
HaLFEn HSD -aD acoustic Dowel type C
min. 1.50 Hmin. 0.75 H
H
Length Length 4 "
4 "
Maximum embedment
Dia
met
er
Dia
met
er
Dowel Component Dowel Length Dowel Diameter ∅ Max. Embedment Sleeve Component
Sleeve Length Sleeve Diameter ∅
HSD-AD-A HSD-AD-D-A 15 3/4 " 1 3/8 " 4 5/8 " HSD-AD-S-AB* 5 " 2 1/2 "
HSD-AD-B HSD-AD-D-B 15 3/4 " 1 3/8 " 4 5/8 " HSD-AD-S-AB* 5 " 2 1/2 "
Dimensions [inch]
Edge Distances and SpacingThe edge distances and connector spacing
required, as shown in the drawing on the
left, are defined by the slab thickness.
min. 1.50 Hmin. 0.75 H
H
Length
Bearing length Length 4 "
4 "∅∅
Dowel Component Dowel Length Dowel Diameter ∅ Max. Embedment Sleeve Component Sleeve Length Sleeve Diameter ∅
HSD-AD-C HSD-AD-D-C 18 1/2 " 1 3/8 " 4 5/8 " HSD-AD-S-C 5 2 1/2 "
Dimensions [inch]
* The HALFEN HSD-AD-A-SET and the HALFEN HSD-AD-B-SET contain the same sleeve; HSD-AD-S-AB
© 2
013
HA
LFEN
Gm
bH, G
erm
any
appl
ies
also
to
copy
ing
in e
xtra
cts.
R -
097
- US
- 03/
13 -
US
03/1
3
ContaCt HaLFEn WoRLDWIDE
www.HaLFEn.com
HaLFEn has a g lobal network of Subs id iary Companies to ass is t you. the main contact in format ion for north amer ica , Europe and as ia i s prov ided be low. For a fu l l l i s t of of f i ces p lease v is i t www.HaLFEn.com
HaLFEn GmbH shall not accept liability for the accuracy of the information in this publication or for any printing errors.
HaLFEn is also represented by distributors in argentina, australia, azerbaijan, Belarus, Brazil, Bulgaria, Chile, Colombia, Croatia/Bosnia- Herzegovina/FYRoM/Montenegro, Cyprus, Estonia, Greece, Hong Kong, Hungary, Indonesia, Ireland, Israel, Japan, Jordan, Kingdom of Saudi-arabia, Latvia, Lebanon, Lithuania, Luxembourg, Malaysia, Malta, Mexico, new Zealand, Peru, Philippines, Republic of Kazakhstan, Romania, Russia, Serbia, Singapore, Slovenia, South Korea, taiwan/RoC, thailand, turkey, Ukraine, United arab Emirates, Uruguay, Vietnam
USa & Mexico HALFEN USA Inc. 8521 F.M. 1976Converse, TX 78109
Phone: +1 800.423.9140 E-Mail: [email protected]: www.HALFENusa.com
Fax: +1 877.683.4910
Fax: +86 - 10 5907 3218
Canada
China
UCC Industries International (Distributor) Units 12 & 13895 Sandy Beach RoadPickering, Ontario, L1W 3N7
Provinces of British Columbia and Alberta: Please contact HALFEN USA Inc.
HALFEN Construction Accessories Distribution Co.Ltd.Room 601 Tower D, Vantone CentreNo.A6 Chao Yang Men Wai StreetChaoyang DistrictBeijing · P.R. China 100020
Phone: +1 905.831.7724 E-Mail: [email protected]: www.ucci.ca
Phone: +86 - 10 5907 3200E-Mail: [email protected]: www.HALFEN.cn
Fax: +1 905.831.5872
Fax: +91 22.4202.4001
Fax: +49 2173 970-123
India
Germany
CRH India Management Services Pvt. Ltd.73-C, 3 North Avenue, Maker Maxity, Bandra-Kurla Complex, Bandra (East), Mumbai 400 051
HALFEN GmbH Liebigstrasse 14 40764 Langenfeld
Phone: +91 22.4202.4000 E-Mail: [email protected] Web: www.HALFEN.in
Phone: +49 2173 970-0 E-Mail: [email protected] Web: www.HALFEN.de