habiteq installers catalogue final version

11
GE Consumer & Industrial Power Protection GE imagination at work HabiTEQ TM Flexible home automation for energy efficiency, safety and comfort

Upload: sumer-land

Post on 04-Jun-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 1/11

GE Consumer & IndustrialPower Protection

GE imagination at work

HabiTEQTM

Flexible home automation 

for energy efficiency, safetyand comfort

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 2/11

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 3/11

5

INP08/16Input module

INP08/230Input module

HabiTEQTM HabiTEQTM

4

• Fast & Flexible two wire Bus system• Quick & Easy configuration• “Plug&Play” operation!

INP08 230Input module

• “P ug&P ay” operat on!

ANR04Analogue dimmer modulefor fluorescent tubes

DIM 04/500immer module

00VA

DIM04/300Dimmer module

300VA

SMS01Mobile interface module

CTL16 up to 256Controller

REL044 Relay module

Home automation modules

ROL022 Shutter relay module

REL088 Relay module

Separate cable compartment (enclosure types C-D-E-F)Enclosure shown is type C7. (See p.10)

ETH02Ethernet module

ANA04Analogue dimmer module

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 4/11

7

HabiTEQTM HabiTEQTM

6

• Quick & Easy installation

Protection equipment

MCB’s forline protection

Surge protection

Potential free and analogue inputsConnections from push-buttons,magnetic contacts and externaldetectors to input module.

Controlled outputs

Contactors forcontrolled socket-outlets

Overvoltageprotection

RCD’s for people protection

Screwless terminalsfor quick connection

D

R

M

D

R

M

Bus connection

Motor

Dimmer

Relay

Conventionalcabled andcontrolledsocket-outlets

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 5/11

8

HabiTEQTM HabiTEQTM

8 types of enclosuresto suit every requirement

Type B-FFix-o-Rail 144 F

Flush Mounting

Type B-SFix-o-Rail 144 S

Surface Mounting

Type BVP-SYSTEM MV/MS

MW= Wall MountingMS= Floor Standing

Type AFix-o-Rail 150

Surface Mounting

Rows Type A Cod e H x W x D Mod /R ow Tota l Mo d

4 FOR 150 A4 750x355x150 18 72

Rows Type B-F Code H x W x D Mod/Row Total Mod

4 FOR 144F B4F 800x740x(35)140 24 96

5 FOR 144F B5F 950x740x(35)140 24 120

6 FOR 144F B6F 1100x740x(35)140 24 144

Rows Type B-S Code H x W x D Mod/Row Total Mod

4 FOR 144S B4S 800x740x140 24 96

5 FOR 144S B5S 950x740x140 24 120

6 FOR 144S B6S 1100x740x140 24 144

Rows Type B Code H x W x D Mod/Row Total Mod

4 VP MW B4 650x550x210 24 96

5 VP MW B5 800x550x210 24 120

6 VP MW B6 950x550x210 24 144

7 VP MW B7 1100x550x210 22 154

8 VP MW B8 1250x550x210 22 176

9 VP MW B9 1400x550x210 22 198

12 VP MS BS12 1980x550x210 20 240

• Standard:- equipped with compact MCB’s Unibis™. - external wiring directly on input modules.- cables from socket circuits directly on MCB’s- wiring of controlled outputs on terminals.- single phase 40A

• Standard:- external wiring directly on input modules.- cables from socket circuits directly on MCB’s- wiring of controlled outputs on terminals.• Optional: equipped with compact MCB’s Unibis™ (max.40A).

• Standard:- external wiring directly on input modules.- cables from socket circuits directly on MCB’s- wiring of controlled outputs on terminals.• Optional: equipped with compact MCB’s Unibis™ (max.40A).

• Standard:- external wiring directly on input modules.- cables from socket circuits on terminals- wiring of controlled outputs on terminals.• Optional: equipped with compact MCB’s Unibis™ (max.40A).

9

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 6/11

10

HabiTEQTM HabiTEQTM

Type CVP-SYSTEM MW/MS

Type DVP-SYSTEM MW/MS

Rows Type C Code H x W x D Mod/Row Total Mod

5 VP MW C5 800x800x210 22 110

6 VP MW C6 950x800x210 22 132

7 VP MW C7 1100x800x210 22 154

8 VP MW C8 1250x800x210 22 176

9 VP MW C9 1400x800x210 22 198

12 VP MS CS12 1980x800x210 22 264

Rows Type D Code H x W x D Mod/Row Total Mod

5 VP MW D5 800x1050x210 34 170

6 VP MW D6 950x1050x210 34 204

7 VP MW D7 1100x1050x210 34 238

8 VP MW D8 1250x1050x210 34 272

9 VP MW D9 1400x1050x210 34 306

12 VP MS DS12 1980x1050x210 34 408

• Standard:- separate cable compartment (in- and outgoing cables)- cables from socket circuits on terminals.- wiring of controlled outputs on terminals.- wiring of inputs on terminals.• Optional: equipped with compact MCB’s Unibis™ (max.40A).

• Standard:- separate cable compartment (i n- and outgoing cables)- cables from socket circuits on terminals.- wiring of controlled outputs on terminals.- wiring of inputs on terminals.• Optional: equipped with compact MCB’s Unibis™ (max.40A).

11

Type EVP-SYSTEM MW

Type FQuixtra™ 630

Rows Type E Code H x W x D Mod/Row Total Mod

5 VP MW E5 800 x1300x210 38 190

6 VP MW E6 950 x1300x210 38 228

7 VP MW E7 1250x1300x210 38 266

8 VP MW E8 1400x1300x210 38 304

9 VP MW E9 1980x1300x210 38 342

• Standard:- separate cable compartment (in- and outgoing cables)- cables from socket circuits on terminals- wiring of controlled outputs on terminals.- wiring of inputs on terminals.• Optional: equipped with compact MCB’s Unibis™ (max.40A).

• Standard:-separate cable compartment (in- and outgoing cables)- cables from socket circuits on terminals- wiring of controlled outputs on terminals.- wiring of inputs on terminals.• Optional: - equipped with compact MCB’s Unibis™ (max.40A).

- plain door (modules compartiment)

Rows Type Code H x W x D Mod/Row Total Mod

5 QuiXtra 630 F5 750x1240x250 36 180

6 QuiXtra 630  F6 9 00 x1 24 0x2 50 3 6 2 16

7 QuiXtra 630  F7  1 05 0x 12 40 x2 50 3 6 2 52

8 QuiXtra 630  F8 1200x1240x250 36 288

9 QuiXtra 630  F9 1 60 0x 12 40 x2 50 3 6 3 24

10 QuiXtra 630 F10 1750x1240x250 36 360

12 QuiXtra 630 F12 2050x1240x250 36 432

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 7/11

13

Relay ModulesA choice of 3 different relay modules is offered to suityour switching application.The relay module has 4 or 8 normally open, indepen-dently controlled contacts that can handle up to 16Aeach. The relay module does not have any specificfunction. It can handle all switching functions: monos-table (bell), bistable (on/off), timer, interval, thermostatoutput, etc.

For shutter/blind/curtain control, the shutter moduleROL02 must be used. For heavy inductive loads (manyfluorescent lights) with a high capacity or bipolar appli-cations, contactors need to be added. The relay modulecontact will then activate the coil of the contactor.

Each of the relay outputs have a unique serial number(E.g REL08 has therefore 2 serial numbers) enablingprogramming anywhere and anytime. All programmingremains internally stored in a nonvolatile memory.

After a voltage cut-off, the outputs return to their latestposition.

A bipolar automatic fuse with a maximum of 16A mustbe placed on the feeder.

RELAY MODULES REL04 REL08 ROL02 (Shutter/Blinds)

Power supply AC 230V +/- 10%, 50..60Hz - maximum

Max. protection needed 16A/2P

Bus load 10mA at nominal 13,8V

Ch ar act er ist ic co nsu mpt io n 4 .7 VA m ax im um (al l re la ys ON) 9 .6 VA m ax im um (al l re la ys on ) 2 .8 VA (t yp ic al )

Internal fuse 100mA (relay control power) 6.3A

Insulation voltage 3 kV (tested)

Fitting DIN rail

Ouputs

TypeOUT1–OUT4:

4 normally open single contactsOUT1–OUT8:

8 normally open single contacts

UP1/2 – DN1/2: 4 potential-freenormally open single contacts

UP1 – DN1 and UP2 – DN2:internally locked contacts

Rated current 16A (resistive @ 230Vac and 30Vdc)

Contact resistance 100mOhm

Set/Reset time 15ms max / 5ms max

Endurance 20mil operations

Rated load Resistive load (cos phi = 1) 16A at 230Vac; 16A at 30Vdc

Inductive load (cos phi = 0,4; L/R=7ms) 8A at 230Vac; 8A at 30Vdc

Maximum switching power Resistive load (cos phi=1) 2300VA at 230 Vac 300W at 30Vdc

Inductive load (cos phi=0,4; L/R=7ms) 1150VA at 230Vac 150W at 30Vdc

LED indication Green light: power supply Green light: power supply

Red l ig ht : Start-u p 2 s , an d du ri ng p rogrammi ng Red li gh t: Start- up 2 s, an d d ur in g

O ra ng e l ig ht 1- X : Ou tp ut 1 to x a ct iv e O ra ng e l ig ht 1- 4: Up 1/ 2– Dn 1/ 2 a ct iv e

Dimensions 6 modules 9 modules 6 modules

12

HabiTEQTMHabiTEQTM

Automation Modules

CONTROLLERS CTL16 CTL32 CTL64 CTL256 CTL256BEX02 CTL256BEX04

Power supply 18Vdc/3,9A (supplied with controller) 2 x 18Vdc/3,9A

Output bus 13,8Vdc/500mA

Characteristic consumption 2VA typical ( with no bus load)

Number of outputs 16 32 64 388

Bus connections 2 (500mA) 4(500mA) 6(500mA)

Logical functions AND/OR/ IF.. THEN.. ELSE..

Protection - fuse 1 AT 1AT 1AT

Fitting DIN rail

Dimensions 6 modules (105mm) 9 modules 12 modules

Sequences or scenes 8 16 32 128

Back-up memory time 10 years

230VAC50Hz

L 16A

N

FUSE1AT OUT1

RELAYMODULE REL04 SERIAL

50Hz

230V

Each contact:Max. switchedcurrent:16A at 230Vac

Max. switchedPower:2000VA

1......................................................................

.....................................................................

.....................................................................

.....................................................................

2.

4.

3.

Ph N

O UT 2 O UT 3 O UT 4

BUS

A 1 A 2 A 1 A 2

BUS

18Vdc/1.4A

CONTROLLERCTL 16 ... .......256

BUS2A1 A2A1 A2

BUS2BUS1

FUSE1 AT

POWER

A1 A2BUS1

BUS1 - BUS2:

Nominal tension : 12VdcMax. current : 500mA

Modules

18Vdc/3,9A

POWERSUPPLY

A1 A2

230VAC50Hz

L 16A

N

M

MM

L 16A

N

1.

OUT1 OUT2 N NN OUT3 OUT4

....................................

5. .................................... 6.

2.

.................................... 7. ....................................

3. .................................... 4. ....................................

8. ....................................

RELAYMODULE REL08

Each contact: max. switched current:16A at 230Vac

SERIAL

.....................................

SERIAL

50Hz230V

NC N

BUSA1A2

BUSA1A2

OUT5 OUT6 N N N OUT7 OUT8

230VAC50Hz

L 16A

N

M1 M2

Each contact:Max. switchedcurrent:16A at 230Vac

Max. switchedPower:2000VA

1......................................................................

.....................................................................

.....................................................................

.....................................................................

2.

4.

3.

UP/DOWN ROL02 SERIALBUSA 1 A 2 A 1 A 2

BUS

FUSE1AT 50Hz

230VPh Ph UP1 Ph UP2NC DN1 NC DN2N

A1 A2BUS2

A1 A2BUS2

A1 A2

Modules Modules Modules Modules

230VAC50Hz

L 16A

N

18Vdc/3,9A

POWERSUPPLY

POWER CONTROLLERCTL256-BEX02FUSE1 AT

FUSE1.2 AT

POWER

18Vdc/1.4A

BUS1 - BUS2:

18Vdc/1.4A

BUS1A1 A2

BUS1A1 A2

B US 1 B U S1A1 A2

BUS2A1 A2

BUS2A1 A2

Nominal tension : 12VdcMax. current : 500mA

BUS1 - BUS2:Nominal tension : 12VdcMax. current : 500mA

ControllersThe controller is the central brain of the HabiTEQ auto-mation system and delivers the necessary power anddata to all the connected modules. The controller isavailable in 6 different versions to suit your installationsize ensuring optimized costs.

The power supply is delivered via a stabilized 18Vdc/2Alead (included). In case of a voltage cut-off a built-in

back-up memory will save all data for at least 10 years.The connection from the power supply to the controllerhas no polarity.

Controllers

Relay Modules

trollers

lay Mo ule

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 8/11

Dimmer ModulesChoices of 4 different dimmer modules are offeredto suit a variety of dimming applications. The mod-ules are controlled and programmable throughthe bus operating digitally with 8-bit precision. Anoptical separation between the inputs and outputs guar-antees safe operation.Multiple possibilities for dimmer control

1. One-button dimmer - Possible to reduce thenumber of control buttons.

2. Two-button dimmer - + and a – button enhancingthe operating comfort.

When a pressed button is kept in, the transit time fromzero to maximum is 5.1s. A short pulse (< 0.3s) will takethe dimmer to zero or to the maximum value in 2.5s.

The maximum value can be adjusted from 20 to 100%.The lighting can also be dimmed automatically aftera set time of 1s to 255min. ideal for bedrooms… If thedimmers are controlled by a sequence the rise time andfall time can be adjusted independently between 0.3sand 20min. Each module has a unique serial numberenabling programming anywhere and anytime. After avoltage cut-off the outputs return to their latest position.

DIMMERS DIM04/300 DIM04/500 ANA04 ANR04

Forward phase dimmer modules Analogue dimmer modules

Power supply AC 230V, 50Hz - maximum (60Hz on request)

Max. protection needed 10A/2P 16A/2P

Bus load 10mA at 13,8V

Characteristic consumption 2.8VA 2.5VA 1.5VA

Internal fuse 6.3A 4 X 4AF NA -

Fitting DIN rail

Insulation voltage 3kV

TypeOUT1 – OUT4 :

Dimmable outputs300Va/channel

OUT1 – OUT4 :Dimmable outputs

500VA/channel

OUT1 – OUT4 :Analogue outputs,0-10V or 1-10V /

channel

OUT1 – OUT4 :Analogue outputs, 0-10V or 1-10V

SW1 – SW4 :4 normally open single contacts

Maximum loadIncandescent load 300VA

at 230VACIncandescent load 500VAat

230VAC10mA

Minimum load 30% of maximum output - -

LED indication Green light : power supply

Red light : Start-up 2 s, and during programming- - - Orange light 1-4 : Output 1 to 4 active

DIP switches - - 4 internal DIPswitches to select the outputs as 0-10V or 1-10V

Rated current - - - 16A

Contact resistance - - - 100mOhm

Endurance - - - 20mil operations

Rated load - - - Resistive load (cos phi = 1) 16A at 230Vac; 16A at 30VDC

- - - Inductiveload(cosphi=0,4;L/R=7ms)8Aat 230Vac;8Aat 30VDC

Maximum switching power - - - Resistiveload(cos phi=1)2300VAat230 VAC300Wat30VDC

- - - Inductiveload (cosphi=0,4; L/R=7ms)1150VAat 230VAC150Wat 30VDC

Dimensions 6 modules 9 modules 6 modules 9 modules

1514

HabiTEQTMHabiTEQTM

230VAC50Hz

L 16A

N

OUT1 OUT2 OUT3 OUT4 SW1 SW2

SW3 SW4

50Hz

Each output:0-10Vdc or1-10vdcMaxCurrent5ma

Each contact:max 16A/250Vac

230VPh N

DIMMERANR04 BUSA1A2

BUSA1A2

1.................................................................................................

................................................................................................

................................................................................................

................................................................................................

2.

4.

3.

Dimmableballasts

230VAC50Hz

L 16A

N

OUT4OUT3OUT2OUT1

DIMMERANA04BUS

A1A2

BUS

A1A2

Dimmableballasts

50Hz

Each output:0-10Vdc or1-10vdcMaxCurrent5ma

230VPh N

1..........................................................................................

2..........................................................................................

3..........................................................................................

4..........................................................................................

230VAC50Hz

L 10A

N

OUT150Hz

DIMMERD IM04/300

FUSE

Cach outputResistiveload

orinductiveload

Max. switchedPower:

300VA/230Vac

6.3AF

230V N

1..................................................................................

.................................................................................

.................................................................................

.................................................................................

2.

4.

3.

Ph N

OUT2 OUT3 OUT4

BUSA1A2

BUSA1A2

N N N

2AF 2AF 2AF 2AF

230VAC50Hz

L 16A

N

OUT150Hz

DIMMERDIM04/500

FUSE

Cach outputResistive load

orinductive load

Max. switchedPower:

300VA/230Vac

6.3AF230V

N

1..................................................................................

.................................................................................

.................................................................................

.................................................................................

2.

4.

3.

Ph N

OUT2 OUT3 OUT4

BUSA1A2

BUSA1A2

N N N

Analogue dimmer ANA04Suitable for controlling four analog dimmersoperating with input voltages of 0-10V or 1-10V. Thismodule can be used for dimming very large capacities.There are four internal DIPswitches. These can be usedto set each output to 0-10V or 1- 10V. It must be notedthat the control voltages must not be connected to themains. The negative terminals are internally linked. Thecontrol and programming are done through the 2-wirebus, one or two button dimmer control.

Dimmer module DIM04/300-500Module for a DIN-rail, suitable for dimming 4 loads of 40-300/500VA. The phase offset of each load is measuredseparately thus allowing the use of resistive (light bulbs)and inductive loads (conventional transformers). Electronictransformers can be used if they operate according to thephase leading principle. For the 300VA dimmer modulesa 2AF type fuse must be provided per output. Ensureadequate ventilation in the fuse box.On the 500VA dimmer modules,each dimmer output is fusedinternally with a 4AF fuse. A bipolar automatic fuse of amaximum of 16A must be placed on the mains power.

Note an additional filter module will be supplied with

300/500Va dimmers

Analogue dimmer ANR04Each analog output controls a relay contact, whichreleases when the output is on 0. This contact candisrupt the mains voltage so that the fluorescent lampsgo out completely. There are four internal DIP switches.These can be used to set each output to 0-10V or 1-10V.It must be noted that the control voltages must not beconnected to the mains. The negative terminals areinternally linked. The control and programming is donethrough the 2-wire bus, one or two button dimmercontrol.

Dimmer Modules

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 9/11

There are 8 or 16 optically insulated inputs.Each input needs a voltage to be active.This can be 12Vac/dc if connected between B and C (consumptionapproximately 10mA)

If there are inputs with potential-free contacts they can be connectedto the module via 12Vac. The required voltage is provided on the topand bottom sides of the module.

Led indication :Green light (right): bus powerGreen light (middle): mains powerRed light: data transfer + error LED

Product description

Module for DIN-rail, suitable for controlling four analogue inputsignals. The input signals can be four Pt100 - Pt1000 temperaturesensors or four analog input signals 0-10V. The temperature sensorsare to be connected to terminals PT1 till PT4. One can use a fourwire connection or a two wire connection. When using a two wireconnection terminals A-B and C-D should be short-circuited. Inputterminals ANA1 till ANA4 are used for importing any analog signalfrom 0-10V.

Remark: There is no possibility to have simultaneously a tempera-ture reading at PT1 and an analogue signal on ANA1. If PT1 is usedANA1 is no longer available and vice versa. Although a combina-tion of for instance a PT1 and an ANA2 is possible. Each modulehas a unique serial number enabling programming anywhere andanytime. All programming remains internally stored in a nonvolatilememory. After a voltage cut-off, the outputs return to their latestposition. A bipolar automatic fuse of a maximum of 16A must beplaced on the mains power.

INPUT MODULES INP04 INP08 INP16 INP08/230 INPA04

Digital input module analogue input module

Power supply 230Vac/50..60Hz

Bus load 20mA at 13.8V 10mA at 13.8V

Characteristic consumption 2.3VA@230Vac 2.8VA

Insulation voltage 3kVFitting Typically inside

conventionalswitch enclosure

on wall

DIN rail

Inputs

Number4 potential-free

inputs"8 potential-free

inputs16 potential-free

inputs

8 (12Vac/dc or 230Vacselectable by connec-

tion)

4 analogue inputs or 4 anologueoutputs

Input function(Configurable through

software serial manager)

Pusht button = button that is open when inactive (e.g. doorbell).Normal open = contact that is open when inactive.

Normal closed = contact that is closed when inactive.Switch = single-pole conventional switch.

Can be configured by SW :-1. PT100,PT1000

or2. 0-10V input

LED indication Green light : power supply Green light : power supply.

Red light : Start-up 2 s, and during programming

Dimensions 32x37x12mm 6 modules 9 modules 6 modules

1716

INP04This module can be used to interface with any conven-tional switch to the bus. The size of the module permitsinstallation within the switch enclosure.

INP08/INP16

There are 8 optically insulated inputs.Each input needs a voltage to be active.This can be:• 12Vac/dc if connected between B and C (consumption

approximately 10mA)• 230Vac if connected between A and C (consumption

approximately 1W)

• Orange LED lights positioned near inputs 1-8 indicate if input is active.

If there are inputs with potential-free contacts they can be connectedto the module via 12Vac. The required voltage is provided on the topand bottom sides of the module.

INP08/230

C I N1 IN2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 C ANA1 ANA2 ANA3

IN1..IN16: potentialfreeOptional:ANA1..ANA8: analogueIN 0-10VC=commonNC=Not connected

OnlyIN1toIN8operationalforINP08

16AL

N

230VAC50Hz

ANA4

I N9 I N1 0 I N 11 I N1 2 I N1 3 I N 1 4 I N 1 5 I N 1 6 A NA 5 A NA 6 A NA 7 ANA8

BUS BUS

A 1 A 2 A 1 A 2C C

230V

50HZ

Ph NC N

INPUTINP 08/16

230VA50Hz

L 16A

N

BUSA2A1 A1

BUSA2

230V/1.5VAOutputmax100ma1A 1B 1C

INPUTMODULE INP08/230

INPUT:

XA-XB=max 230Vac/1W

XB-XC=mas12Vac/dc/10ma

NC= not connected

23 0VA C 2 30 VAC12V

2 A 2 B 2 C 3 A 3 B 3 C 4 A 4 B 4 C

5 A 5 B 5 C 6 A 6 B 6 C 7 A 7 B 7 C 8 A 8 B 8 C

P h N C NNC12Vac

Outputmax100maNC12Vac

BUS2

A1 A2

BUS2

A1 A2

230VAC50Hz

P†100P†1000

or

L 16A

N

A B   C D   A B   C D A B C   DFUSE0,5A

Ph N230 V   PT1   P T2 PT3

ANA1-ANA4Analogue 0-10V

PTI-PT4PT100... orPT100

INPUTAN104

P T1 A NA 1

+   _ A B   C D

ANA2

+   _ ANA3

+   _ ANA4

+   _  

+   _ 

AB

CD

P†100P†1000

10V DCUseonlyoneata time,either12Vac or230Vac

INPUTMODULE INP04

C V+ L1 L2 L3 L4       B       U       S

INPUTCONTACTSPOTENTIAL FREE LEDS

IN2IN1 IN3 I N4

General specifications :· Power supply : 230Vac +-10%, 50 Hz - maximum protection 6A/2P· Insulation voltage : 3 kV tested· Characteristic consumption : 2,8VA· Bus load : 10mA at nominal 13,8V

· Internal fuse : 500mA si ngle-phase· Max installation altitude : 2.000m

 Inputs :· PT1 – PT4 : 4 temperature sensors type Pt100 or Pt1000ANA1 – ANA4 : 4 analogue input signals 0-10V

INPA04

Input ModulesChoice of five different input modules are available inthe HabiTEQ to connect external contacts such as so-lar/wind detector, movement detector, door switches,push-buttons and analogue sensors.8/16 optical isolated inputs are provided, which mustbe potential-free.

The input contacts can be selected and set usingthe PC software:

• Push-button = button that is open when inactive(e.g. doorbell)

• Normal open = contact that is open when inactive• Normal closed = contact that is closed when inactive• Switch = single-pole conventional switch.

The maximum length of each input is 200 m.The cable type is irrelevant as long as the 2 wires areeach 1mm2. (Contact load 1mA) Each of the 4 inputshas a unique serial number. (E.g. So INP08 has 2 se-rial numbers and INP16 has 4 serial numbers). Thecommon (1st connector on the right top and bottom)is connected internally. One may connect thesetogether with other ‘INP16’ modules.

! Always use potential-free contacts!never connect or disconnect modules whilethe bus is energized!

Input Modules

HabiTEQTMHabiTEQTM

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 10/11

Communication

Interfaces

1918

DLL to communicate with all features of the system,is available as freeware:• The software when installed on the PC and connected

to the HabiTEQ allows performing the following:• Initializing the controller (assign outputs, switching

behavior, timer, parameters, shutters, dimmers, etc.)• Addressing of input and output modules• Creating sequences• Setting switching times• Constructing logical functions

SER02

BUS

10/100 BASE-TETHERNET

MACaddress

TCP/IP BUSA1 A2 A1 A2

BUS

ETHERNETINTERFACE ETH02230V50Hz

Ph N

230VAC50Hz

L 16A

N

MOBILE INTERFACE SMS01

SMS MODULE

Power supply AC 230V, 50..60Hz - maximum

Power guard connection Power guard inputs: Connection I1 – C : 230Vac – max 1VA Connection I2 – C : 12Vac – max 1VA

Bus load 10mA at 13.8Vdc

Characteristic consumption 2.3VA

Internal fuse 1AT

Insulation voltage 3kV

Ou tp uts U p t o 9 6 o utp ut s ( in cl udi ng se qu en ce s) c an be ac tiv at ed or vi ew ed

Access and agenda phone numbers Max. 8 phone numbers (+1 emergency number) can get access to the system

Control possibilities SMS texts can have different defined texts for different users and different status definition

Alarm messages Max.16 alarm messages can be sent to all numbers

Warning power down to all numbers if battery is connected

Pincode possibility of enable / disable

SIM card Not included

Antenna In built antenna on top and optional external antenna

Band width Tri-band

Dimensions 6 modules

General specifications for all automation modulesO pe ra ting t em pe ra tu re 1 0 t o 5 0º C w it ho ut co nd en sa tion

S to ra ge t em pe ra tu re - 10 t o 6 0º C w it ho ut c on de nsat io n

Maximum humidity 93%, no moisture condensation

Protection degree IP20, EN 60529

Fitting DIN rail to DIN EN 50022

230VAC50Hz

L 16A

N

SMSMO DULE SMS01FUSE1 AT

PH

230Vac

Powercontrol:

12Vac

230Vac

PowerFail

Useonlyoneatatime, either

12Vac or230Vac.

11-C=230Vac12-C=12Vac

2.3VA

N

BUS11 12 CA1 A2 A1 A2

BUS

signal

Mobile Interface ModuleThe SMS01 is a DIN mounted module that can be installedwithin the HabiTEQ. The power supply is 230Vac. If themodule must work when power drops, a UPS or inter-nal rechargeable battery (Li-Ion) needs to be installedoptionally. A connection (230V or 12V) is available inorder to be able to send a message when the powerdrops.

The SIM card must be inserted on top of the moduleinto the SIM card reader. If the module is mounted in ametal distribution box or on a place with bad networkcoverage (cellar, concrete....) it is recommended to addan optional antenna.

Features:• Maximum 8 phone numbers (+1 emergency number)

can get access to the system• View and control outputs: max 96 channels (sequences

included) can be activated  - Confirmation to selectable numbers  - Comparison SMS texts with more than 1 user defined

texts e.g. “KITCHEN ON” or “KTC ON”  - Different value definitions (e.g. ON- OFF - 0 - 1 - 50%...)• Alarm messages:  - Maximum 16 different alarm messages (e.g. “burglar

alarm”, “fire”,” power down etc.) can be sent to up to8 + 1 phone numbers with intervals selectable from1min…. 10min.) and repeat rate 1-5 for each SMScan be set.

  - Stop sending alarm texts when “SMS - STOP”message is received.

  - Warning power down to all Numbers

Communication InterfacesCommunication can be established through PC viaan Ethernet connection or through a serial adapter forprogramming the system. Further control of the HabiTEQcan also be done through a mobile phone using basicpre-configured SMS messages.

Ethernet/WEB interfaceThe Ethernet interface module for DIN rail allows theHabiTEQ system to communicate with a PC or network.The module can be connected to the bus in any loca-tion and be linked to a network card of the PC, hub,Switch or router via an RJ-45 connector. The suppliedsoftware allows programming and operating of theinstallation. Multiple modules can be positioned on thebus. This interface has a built-in web server for the

on-line operation of a control table (96 channels and6 menus) via any Internet browser. Protocol details tocontrol the HabiTEQ system via TCP/IP or interface tohigher end BMS system can be provided on request.

Serial interfaceWhen the interface  SER02  (external module)  is con-nected on a router to the Internet, it is possible to useall features from anywhere in the world. The serialinterface allows the HabiTEQ system to communicatewith a PC or a modem. The module can be connectedto the bus in any location and be linked to the PC’s COMport via a SUB-D9 connector. The supplied free “SERIALMANAGER II” software allows programming and oper-ating the installation. Connection to the USB port of aPC or laptop occurs via the USB Serial Cable Interface(USB01). The first serial interface in the installation hasbeen pre-programmed on ADDRESS 02. Multiple serialmodules can be positioned on the bus subject to thespecification of the desired address when ordering.

COMMUNICATION INTERFACES ETH02 SER02

Ethernet interface Serial interface

Power supply 230Vac/50..60 Hz Supplied by the bus

Max. protection needed 16A/2P -

Bus load 10mA at 13.8V 15mA

Internal fuse 100mA -

Characteristic consumption 2VA -

Insulation voltage 3kV

Fitting DIN rail Wall mounting

Connections

Type

- RJ-45 connector for connection to network- Grey FTP crossed over cable : direct con-nection between PC and ethernet interface.- Yellow UTP cable : connection via router,

switch, hub

Connects serial SUB-D9 connector to Qbus

LED indicationG ree n li gh t : po wer s up pl y G ree n l ight : p owe r s up pl y

Red light : start-up 2s and during programming

Communication

Protocol TCP/IP with an integrated webserver -

Speed - Baud rate 19200bits/s

Visualization & ControlBuilt-in web server / Control upto 96 channels

and 6 menus via any Internet browser.Through serial manager software

Dimensions 6 modules 75x75mm built in frame

Note: Pincode can’t be enabled or disabled when theSIM card is in the module. Pincode authentication ofthe SIM card needs to be removed with normal phonebefore placing it in the module.

HabiTEQTMHabiTEQTM

8/13/2019 HabiTEQ Installers Catalogue Final Version

http://slidepdf.com/reader/full/habiteq-installers-catalogue-final-version 11/11

@

   4   6   3   3   4 

Do you want to learn more about HabiTEQTM

?Please contact your installer or distributor.

He’s the right person to answer allyour questions about GE products andhome automation systems.

www.ge.com/ex/powerprotection

GE CONSUMER & INDUSTRIALPOWER PROTECTIONNieuwevaart 51B-9000 Gent - BelgiumTel. +32/9 265 21 11Fax +32/9 265 28 00E-mail: [email protected]

Customer serviceTel. 0800/74410fax 0800/75200e-mail: [email protected]

GE CONSUMER & INDUSTRIAL HUNGARYVáci út 77H-1340 BudapestHungary

Customer serviceTel. +361 447 6046Fax +361 447 5060e-mail: [email protected]

GE Consumer & IndustrialPower Protection

 

Ref. R/2371/E/X 1.0 Ed. 09/09

© Copyright GE Consumer & Industrial 2009

GE imagination at work

Your local salesman or contact information

ecomaginationSM

GE’s company-wide commitment tohelp customers and consumers meetenvironmental challenges