EikonSingle Gas Recyclable Monitor
Toxic and oxygen gases
Eikon With two years of maintenance free continuous monitoring in a rugged and robust over mould case, Eikon is fit for purpose in harsh environments.The simplest recyclable on the market with outstanding audible and visual alarms, it provides effective warning of hazardous conditions without the need for training or user interpretation.
Reliable
2 years guaranteed maintenance-free lifeEnd of life indicationConfidence ‘Tap Tap’ test assures correct operation
Alarms
Highly audible 94dB alarmBright, multi-angled LEDs for maximum visibilityDistinctively different alarm tone and self check tone
Rugged
Easy and unobtrusive to wearPatented pocket clip makes sure the unit stays putDust and water tight to IP65
Simple
No parts or servicing neededNo accidental switch off, unit is always onNo training required
Weight 125g (4.4oz)
Dimensions
(H x W x D)
69 x 63 x 38mm 2.7 x 2.5 x 1.5 inches
Audible Alarms 94dB @ 30cm
Visible Alarms 4 multi-angled red LED
Typical Response
Time
5 seconds
Operating Life Continuously for 2 years. Pull strip to activate.
Self Test/
Confidence
Indicator
Green LED flashes every 15 seconds. A double tap ("Tap/Tap") on a hard surface initiates a self test. An LED sequence and multi-tone bleep is performed upon successful completion. If red LED flashes rapidly the instrument is faulty. In the last week of life, a slow red LED flashes as well as the green confidence LED.
End of Life End of life is indicated by 'n' red LED flashes to indicate 'n' number of weeks of life left
Temperature
Range
-20OC to +50OC (-4OF to +122OF)
Ingress Protection IP65
Humidity 5-95% RH non-condensing
Approval Codes
Europe
International
N. America
ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +50°C)BASEEFA09ATEX0247IECEx BAS 09.0114 Class 1, Div 1 Groups A,B, C, D
Safety Standards
Europe &
International
N. America
EN50014, EN50022, prEn50271UL 913 & CSA 22.2
EMC Compliance EN50270
Accessories Eikon accessory bump test console, commander, swipe cards for commander, mini-printer, printer paper roll, module storage units
Specification: Eikon
www.crowcon.com
Eikon
Crowcon reserves the right to change the design or specification of the product without notice.
Area reserved for distributor stamp
P01018 GB Issue 11, Oct11
Typical ranges and alarms
Gas Range Standard Alarm (UK)
H2S 0-50ppm 5ppm
CO 0-500ppm 30ppm
O2
0-25% VOL 19% VOL
NH3 0-50ppm 25ppm
CI2
0-5ppm 0.5ppm
Eikon is also available in a dual CO/H2S version
Eikon Accessory
This “one touch” bump test solution offers the ability to check Eikon’s status, change alarm level settings, bump and calibrate. Ideal for point of issue use, Eikon accessory is simple and quick to use. Status report commands, like calibration and zeroing, are transmitted with swipe cards for ease of use without a PC. These reports can be printed so the identity of Eikon can be detailed and allows a traceable audit trial.
UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]
US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]
NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]
SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]
CN: Unit 316, Area 1, Tower B, Chuangxin Building, 12 Hongda North Road, Beijing Economic & Technological Development Area, Beijing, PRC 100176 +86 10 6787 0335 [email protected]
Eikon is a range of tough, reliable single gas recyclable monitors designed to withstand the harshest environments with 2 years continuous maintenance-free use.
Part Number Description
C01780 Eikon H2S, 0-50ppm hydrogen sulphide ATEX approved
C01781 Eikon CO, 0-500ppm carbon monoxide ATEX approved
C01782 Eikon O2, 0-25% oxygen ATEX approved
C01809 Eikon CO/H2S carbon monoxide/hydrogen sulphide ATEX approved
C01904 Eikon NH3, 0-50ppm ammonia ATEX approved
C01900 Eikon Cl2, 0-5ppm chlorine ATEX approved
C01870 Eikon H2S, 0-50ppm hydrogen sulphide CSA approved
C01871 Eikon CO, 0-500ppm carbon monoxide CSA approved
C01872 Eikon O2, 0-25% oxygen CSA approved
C01812 Eikon H2S, 0-50ppm hydrogen sulphide UL approved
C01813 Eikon CO, 0-500ppm carbon monoxide UL approved
C01814 Eikon O2, 0-25% oxygen UL approved
C01905 Eikon NH3, 0-50ppm ammonia UL approved
C01901 Eikon Cl2, 0-5ppm chlorine UL approved
Product Ordering Information
CO2
H2S
CI2
NH3
O3
CO
O2
CH4
SO2
CO2
H2S
GasmanMonitor de gases individual
para proteção pessoal Gases tóxicos, oxigênio e inflamáveis
Simples Operação com um único botão Visor fácil de ler e com iluminação de fundo para status
de operações e diagnóstico de gases Aviso nítido de necessidade de calibração
Alarmes Alarme sonoro 95dBA Alarme visual duplo vermelho/azul impressionante Alarme interno vibratório 2 níveis de alarme instantâneo e alarmes TWA
para as versões tóxicas
Robusto Revestimento robusto de policarbonato Modelação abrangente fornecendo resistência a fortes impactos Resistente à água e à poeira em conformidade com IP65
Flexível Soluções de sensores de oxigênio, tóxicos e inflamáveis Baterias com versões recarregáveis e de íons de lítio disponíveis Registros extensivos de eventos e dados Módulos de sensores inteligentes e completamente
intercambiáveis
Gasman Com uma construção robusta à prova de impactos e em conformidade com IP65, o Gasman oferece uma vasta gama de gases que inclui seis opções de calibração de inflamáveis.
Projetado para uso nos ambientes mais agressivos, o Gasman fornece uma combinação imbatível de alarmes com iluminação clara e em sons altos com uso de um design extremamente compacto e leve.
SSS
Especificações:
Gases e faixas As faixas e os alarmes requeridos podem variar de acordo com o país
unidades tóxicas também possuem alarmes Time Weighted Average (TWA – concentração média ponderada pelo tempo).
propano, butano, pentano, hidrogênio e etileno como padrão.
O Gasman também está disponível na versão de área segura de CO2 oferecendo a medição de dióxido de carbono de 0-5%.
Alarmes e faixas típicos
Peso
Dimensões Tempos de resposta típicos (T90)Alarmes sonoros 95 dBA
Diversos sons de alarme permitem uma seleção de tons distintos para níveis de alarmes diferentes
Alarmes visuaisvazamento de gases
Alarme vibratório Alarme vibratório interno Visor
indicação proporcional do tempo restante de operação) e modo de exibição. Indicação na inicialização quando a calibração for
quando algum serviço for necessárioModos de Visor Visor normal para níveis de concentração de gases em tempo
real. Memória de visor para leituras de pico e TWALog de dados
como padrão.
Bateria Bateria de íon de lítio recarregável para todos tipos de gases Bateria de lítio não recarregável para tóxicos e oxigênio (excluindo CO2)
Tempo de operação Não recarregável: Até 2 anos
Observação: O tempo de operação dependerá do padrão de funcionamento e da ocorrências de alarmes. Alarmes frequentes, ou de longa duração, e o uso do bipe de
Amostragem Aspirador manual opcional Temp. operacional faixa
-20°C a +65°C
contato com a Crowcon se as temperaturas operacionais excederem 40°C por períodos longos
Umidade 20-90% UR Proteção contra líquidos e poeira
IP65
Europa
Internacional
EUA
Tóxicos/O2:
Tóxicos/O2:
Europa EUA
Padrões de operação Interface de PC
Calibração O Gasman pode ser calibrado com frequência com o software Portables PC ou utilizando o Checkbox IMH
Acessórios O Gasman é fornecido com um agrafo integral
Acessórios opcionais
Arreios para capacete, placa de arreios universal, alça de ombro, coleira para peito, estojo de couro, conjunto de aspirador
A Crowcon se reserva o direito de alterar o design ou as especificações do produto sem aviso prévio.
UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]
US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]
NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]
SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]
www.crowcon.com
Gasman
Kit de Teste de Gás O Kit de Teste de Gás fornece uma forma simples e conveniente de realizar um teste de pré-uso de resposta (bump) ou uma calibração.
Opções de recarregamento O Gasman pode ser fornecido com:
Carregador de unidade individual com plugues para Reino Unido, Europa ou EUA ou alimentação cabeada de 110 V/230 V Carregador Comms com opções conforme acima incluindo interface de PC Multicarregador de 5 vias com alimentação universal Adaptador para carregamento em veículos
Area reserved for distributor stamp
Gasman é uma linha de monitores pessoais de gases compactos e robustos que foi projetada para ser usada nos ambientes mais agressivos.
P01019 BR Edição 8, 2010
Gás Faixa Alarme típico (Reino Unido)
Inflamáveis 0-100% LIE 20% LIE
Oxigênio
0-25% 19/23%
Sulfureto de hidrogénio 0-100 ppm 5 ppm
Monóxido de carbono 0-500 ppm 30 ppm
Dióxido de enxofre 0-20 ppm 1 ppm
Cloro 0-20 ppm 0,5 ppm
Dióxido de nitrogênio 0-20 ppm 1 ppm
Amônia 0-100 ppm 25 ppm
Ozônio 0-1 ppm 0,1 ppm
Hidrogênio
0-2000 ppm N/A
Cianeto de hidrogênio 0-25 ppm 5 ppm
Fluoreto de hidrogênio 0-10 ppm 1 ppm
Fosfina 0-5 ppm 0,2 ppm
Flúor 0-1 ppm 0,1 ppm
Fosgênio
0-1 ppm 0,1 ppm
Óxido nítrico
0-100 ppm 25 ppm
Dióxido de carbono
0-5% 0,5 ppm
Códigos de aprovação
Segurança padrão
T3 features:
Robust
Tough over-moulded contraction to resist shock and vibration
Water and dust resistant to IP65 and IP67
Alarms
95dB Audible Alarm Piercingly bright red/blue visable alarm Vibrating alarm
4 Gas Personal Monitor
Oxygen, Toxic and Flammable Gases
Proven to serve the needs of today’s most arduous industrial environments.
Designed with the user in mind, the top mount display, full function data and event logs, audible, visual and vibrating alarms deliver top end performance in a small and lightweight package.
Reliable
Proven sensor technology and software operation ‘At a glance’ operating status Clear calibration due warning
Performance
Li-ion battery with at least 14 hours operation True single button operation Easy to read back-lit display for gas readings and diagnostics
CO2
H2S
CI2
NH3
O3
CO
O2
CH4
SO2
CO2
H2S
web: www.crowcon.com
UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY
+44 (0) 1235 557700 [email protected]
US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845
+1 859 957 1039 [email protected]
NL: Vlambloem 129, 3068JG, Rotterdam
+31 10 421 1232 [email protected]
SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383
+65 6745 2936 [email protected]
PO1024 GB Issue 7 Jan 2010
Crowcon reserves the right to change the design or specification of this product without notice
Tetra 3 is an intuitive 4 gas personal monitor with a top mount display designed to withstand the harshest of industrial environments.
Gases and Ranges Ranges and alarms may vary by country and application which can be configurated as required. Each channel can have two instantaneous alarms. Toxic channels also have TWA alarms.Flammable gas calibration is available for methane, propane, butane, pentane, hydrogen and ethylene as standard.
* T3 is available in a safe area CO2 version offering 0-5% carbon dioxide
measurement. The CO2 sensor replaces the flammable option and can
be supplied with oxygen and toxic sensors.
Gas Range Typical Alarm (UK)
Flam 0-100% LEL 20%O
2 0-25% 19/23.5%
H2S 0-100ppm 5ppm
CO 0-500ppm 30ppmSO
2 0-20ppm 1ppm
O3 0-1ppm 0.1ppm
NH3 0-100ppm 25ppm
*CO2 0-5% 0.5%
WeightDimensions
295g (10.4oz)114 x 71 x 48mm (tapers to 20mm) 4.5 x 2.8 x 1.9 inches
Audible Alarms 95dBMultiple alarm sounds allow selection of distinctive tones for different alarm levels
Visible Alarms Dual colour red/blue flashing LED in gas hazard
Vibrating Alarm Internal vibrating alarm
Display Graphic LCD with backlight, giving simultaneous display for all gas channels. Graphic symbols for battery (with proportional indication of remaining operation time), healthy operation or fault warning. Start up indication when calibration is due, overdue, or service required
Display Mode Normal display for real time gas concentration levels. Display recall for Peak readings and TWA
Datalogging Timed datalogging: 50 hours at 1-minute data rate (3000 records) Threshold logging (starts after adjustable preset level) Event logging: >1500 events
Battery Rechargable Li-ion battery
Operating Time Based on four gas unit with flammable sensor -A 5 hour charge from flat provides at least 10 hours of continuous use. A 12 hour charge provides at least 14 hours of continuous use
Sampling Diffusion or hand aspirator
Operating Temp. Range
-20°C to +55°C (-4°F to +131°F) Toxic and Oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40°C (104°F) for extended periods
Humidity 20-90% RH @ 40°C non-condensing
Ingress Protection IP65 and IP67
Approval Codes Europe
International
North America
ATEX II 2 G Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +55°C)BASEEFA05ATEX0187 IECEx Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +55°C)BAS05.0059 CSA Class I Division 1 Groups A, B, C, D
Safety StandardsEuropeNorth AmericaOperation Standards
EN60079-0, EN60079-11, EN60079-1, 94/9/EC CSA22.2, 152EN50270, EN50271, EN50104, EN45544, EN60079, IEC61508
PC Interface RS232 connection from interface module in charger RS232/USB converter available
Calibration Tetra 3 can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH
Accessories Tetra 3 is supplied with an integral alligator clip
Optional Accessories Universal harness plate, shoulder strap, chest harness, aspirator assembly (flow plate, bulb and 2m/6ft tubing), fixed and telescopic sample probes, and an in-line water trap
Specification
Gas Test Kit The Gas Test Kit provides a simple and convenient means of carrying out either a pre-use (bump) test or a simultaneous four gas calibration (flam, O
2, H
2S, CO only).
Charging OptionsThe T3 can be supplied with: Single way drop in charger with UK,
EU or US plug or in-line 110V/220V supply Single way drop in charger with options
as above including PC interface 5 way multi-charger with universal
power supply Vehicle adapter for in-vehicle charging NEW – Universal charger for vehicle,
wall and desk mounting with a multi-region plug (supplied with EU/UK/US inserts) and status indication
Contact Crowcon for further information.
Area reserved for distributor stamp
O2
H2S
CO
CH4
SO2
NH3
CO2
O3
CI2
NO2
Monitor de Entrada
de Espaço Confinado
Detector portátil de 5 gases
Projetado para atender as necessidades de trabalhadores e gerentes encarregados de trabalhos em espaços confinados, o Gas-Pro oferece a detecção de até 5 gases em uma solução compacta e robusta capaz de suportar ambientes agressivos e uso diário.
Flexível +ve SafetyTM personalizado para os requisitos
organizacionais Monitore 5 gases de várias diferentes opções Soluções multiuso; bombeadas e de difusão que oferecem
vários usos em um detector compacto
Solução para Espaços Confinados Display fácil de visualizar posicionado no topo Bomba interna (opção) Reconhecimento automático de falha de fluxo no
adaptador de vazão Modo de pré-entrada específico e único Indicador de status tricolor +ve SafetyTM
(Segurança Positiva) Totalmente revestido por estojo à prova de choque Operação simples por um único botão Soluções de teste de gás portáteis, de parede e de mesa
Gas-Pro
Área reservado para o selo do distribuidor
Gas-Pro
Monitor de entrada de espaço confinado compacto e robusto capaz de detectar até 5 gases.
UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]
US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]
NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]
SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]
CN: Unit 316, Area 1, Tower B, Chuangxin Building, 12 Hongda North Road, Beijing Economic & Technological Development Area, Beijing, PRC 100176 +86 10 6787 0335 [email protected]
Gases e Faixas Gas-Pro oferece uma vasta gama de sensores, alguns deles são demonstrados abaixo. Gases e faixas podem variar de acordo com o país e aplicação. Cada canal de gás possui dois alarmes instantâneos com canais tóxicos que também contém alarmes TWA.
O Gas-Pro está em estágio de aprovação, portanto os dados incluídos na especificação são padrões, e poderão ser revisados na conclusão
A Crowcon se reserva o direito de alterar o design ou as especificações do produto sem aviso prévio.
Gas Faixa Alarmes
Típicos
Resolução
Tóxico duplo H2S 0-100 ppmCO 0-500 ppm
5 ppm30 ppm
1 ppm1 ppm
Oxigênio 0-25% VOL 19%/23% VOL 0,1% VOL
Inflamável* 0-100% LIE 20% LIE 1% LIE
Dióxido de carbono 0-5% VOL 0,5% VOL 0,01% VOL
Agendado para liberação (entre em contato com a Crowcon para prazo de execução)
Amônia 0-100 ppm 25 ppm 1 ppm
Dióxido de enxofre 0-20 ppm 1 ppm 0.1 ppm
Ozônio 0-1 ppm 0,1 ppm 0,01 ppm
Cloro 0-5 ppm 0,5 ppm 0,1 ppm
Dióxido de cloro 0-1 ppm 0,1 ppm 0,1 ppm
Óxido nítrico 0-100 ppm 25 ppm 1 ppm
Dióxido de nitrogênio
0-20 ppm 1 ppm 0,5 ppm
Especificações:
Tamanho 43 x 130 x 84 mm (1.7 x 5.1 x 3.3)
Peso 309g 4 gases (10.8oz)/340g com bomba (11.9oz) 333g (11.7oz) com bomba (5 gases)/362g com bomba (12.7oz)
Alarmes Sonoro >95dB @ 30 cm (98dB@30 cm em volume alto)Visual – LEDs duplas de todos ângulos vermelha/azul Alerta de vibração
Visor Montagem superior para fácil visualização Com luz de fundo com duas cores (verde/vermelho)
Registro de dados
125hrs em intervalos de 10 segundos (45.000 registros)
Registro de eventos
Alarme, sobre faixa, calibração, bomba, liga/desliga, TWA, 1000 eventos
Bateria Íon de lítio recarregável, >14 hrs (13 hrs de operação bombeada) com base em CH4, O2, H2S, CO O tempo para recarga das baterias menos de 7.5 horas
Amostragem Bomba interna opcional
Temperatura operacional
-20OC a +55OC (-4˚C a +131˚F)+
Armazenamento -25OC a +65OC (-13˚F a +149˚F)
Umidade 10 a 95% RH*+
Proteção contra líquidos e poeira
Testados independetemente para IP65 & IP67
Aprovações (pendentes)
IECEx: Ex ia d IIC T4 Gb Tamb -20˚C a +55˚C ATEX: II 2G Ex ia d IIC T4 Gb Tamb -20˚C a +55˚CUL: Gas detector use in hazardous locations Classe 1, Div. 1, Grupos A, B, C, D only as to intrinsic safety
Conformidade FCC e CE. Em conformidade com a diretiva EMC 2004/108/EC EN50270 e ICED-003
Interface Conexão de dados para soluções de teste de gás e direta ao PC
Carregador/Adaptador
Conecta diretamente com fornecimento de energia de multiregião Adaptador para carregamento em veículos Suporte para mesa Cabo de comunicações e de USB
* Calibrações pellistor disponíveis para metano. Outras calibrações (butano, pentano, propane e etileno) e tipos de gás estão disponíveis, entre em contato com a Crowcon para obter detalhes.
Soluções de Teste de Gás
Soluções para teste de gás no campo e no próprio local, calibração e captura de dados
Q-Test: Teste no próprio campo rápido e fácil I-Test: Estação inteligente de montagem de mesa ou
paredeS-Test: Serviço e manutenção de até 5 detectores
P08013/Edição 1 BP – Setembro 2011
www.crowcon.com
+dependente do sensor de configuração
CO2
H2S
CI2
NH3
O3
CO
O2
CH4
SO2
CO2
H2S
TetraPersonal Multigas Monitor
Oxygen, Toxic & Flammable Gases
TETRA
Tetra is a single button, reliable and robust multigas monitor with optional internal pump. Featuring intelligent sensor modules, shockproof construction and self checking software, Tetra is simple to use and assures reliable gas detection in the toughest of environments.
SimpleSingle button operationEasy to read backlit display for gas readings and diagnosticsClear calibration due warningRechargeable Li-ion battery gives 12 hours of continuous operation
AlarmsLoud 94dBA audible alarmUltra bright dual red/blue visual alarmVibrating alarm
RobustRugged plastic housing with flexible internal assembly to resist shock and vibrationDurable over moulded rubber for added protectionWater and dust resistant to IP65
FlexibleOptional built-in pumpRechargeable and alkaline battery versions availableCompatible with Crowcon Portables PC SoftwareFully interchangeable intelligent sensor modules
Crowcon reserves the right to change the design or specification of the product without notice.
UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]
US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]
NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]
SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]
www.crowcon.com
Area reserved for distributor stamp
Typical ranges and alarms
Gas Range Standard Alarm (UK)
Flammable 0-100% LEL 20% LEL
Oxygen 0-25% 19/23%
Hydrogen sulphide 0-100ppm 5ppm
Carbon monoxide 0-500ppm 30ppm
Sulphur dioxide 0-20ppm 1ppm
Chlorine 0-20ppm 0.5ppm
Nitrogen dioxide 0-20ppm 1ppm
Ammonia 0-100ppm 25ppm
Ozone* 0-1ppm 0.1ppm
Hydrogen 0-1000pm N/A
Hydrogen cyanide 0-25ppm 5ppm
Hydrogen fluoride 0-10ppm 1ppm
Phosphine 0-5ppm 0.2ppm
Fluorine 0-1ppm 0.1ppm
Phosgene 0-1ppm 0.1ppm
Carbon dioxide 0-5% 0.5%
* unpumped only
Specification:
WeightDimensions
498g (1.1lb) Rechargeable122 x 128 x 57mm (4.75 x 5 x 2.25 inches)Non-rechargeable134 x 128 x 57mm (5.25 x 5 x 2.25 inches)
Typical Response Times (T90)
Flammable 20 s, Toxic gas 20 s, Oxygen 10 s
Audible Alarms 94dBMultiple alarm sounds allow selection of distinctive tones for different alarm levels
Visible Alarms
Vibrating Alarm Internal vibrating alarm
Display 128 x 64 graphic LCD with backlight, giving simultaneous display for all gas channels. Graphic symbols for battery (with proportional indication of remaining operation time), pump operation, healthy operation or fault warning. Start up indication when calibration is due within 30 days, calibration overdue, or service required.
Display Mode Normal display for real time gas concentration levels. Display recall for the Peak readings and TWA.
Datalogging Timed datalogging: 50 hours at 1-minute data rateEvent logging >1500 events
Battery Types Rechargeable Li-ion batteryNon rechargeable pack 3xAA Alkaline cells
Operating Time Rechargeable - 12 hour minimum based on pumped
Sampling Hand aspirator or internal electric sampling pump
Operating Temperature Range
-20OC to +55OC (-4OF to +131OF)Toxic and oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperature are likely to exceed 40OC (104OF) for extended periods.
Humidity 20-90% RH
Ingress Protection IP65
Approval CodesEurope
International
North America
ATEX II 2G Ex ia d IIC T4 Gb ( -20OC ≤ Ta ≤ 55Oc)BASEEFA 03ATEX0193IECEX Ex ia d IIC T4 Gb ( -20OC ≤ Ta ≤ 55Oc) BAS04.0024CSA UL/cUL Class I Division I Groups A, B, C, D
Safety StandardsEurope
North America
Operation Standards
EN60079-0, EN60079-11, EN60079-1, 94/9/EC
UL913, CSA22.2, 152
EN50270, EN50271, IEC61508, EN61779, EN45544
Calibrations Tetra can be routinely calibrated manually using the menu, using Crowcon Protables PC software or automatically using Checkbox IMH.
Accessories Tetra is supplied with an integral belt/pocket clip. Pumped units are supplied with a sampling kit
Optional Accessories Universal harness plate, shoulder strap, chest
probes and an in-line water trap.
Gases and RangesRequired ranges and alarms may vary by country and application and can be configured as required. Each gas channel can have two instantaneous alarm levels set. Toxic channels also have Time Weighted Average (TWA) alarms.
Flammable gas calibration is available for methane, propane, butane, pentane, hydrogen and ethylene as standard.
Tetra is also available in a safe area CO2 version offering 0-5% carbon dioxide
measurement.
TETRATetra is a personal multigas monitor with an optional built-in pump designed to reliably detect gas in the toughest of environments.
PO1017 GB Issue 10 May 2010
PC Interface and CalibrationTetra can be routinely calibrated either manually or by using Crowcon Portables PC software or Checkbox IMH packages, providing the user with full configuration control, calibration and access to data and event logs files. An IR link is available using a RS232/USB connection from the PC.
Charging OptionsThe Tetra can be supplied with:
Plug in charging power supplies with UK, EU or US plug or in-line 110V/230V supply10-way multicharger with 90-260V in-line power supply with either UK, EU or US mains leadVehicle lighter socket charger for in-vehicle charging
Gas Test KitThe Gas Test Kit provides a simple and convenient means of carrying out either a pre-use (bump) test or a simultaneous four gas calibration (flammable, oxygen, hydrogen sulphide and carbon monoxide only).
CO2
H2S
CI2
NH3
O3
CO
O2
CH4
SO2
CO2
H2S
Triple Plus+ features:
Rugged construction
Triax™ casing will not crack or shatter when dropped Unique internal design will resist the harshest treatment
Full buoyancy makes recovery from water possible
Flexible
Available for diffusion, manual aspiration or pumped sampling
Interchangeable sensor modules Comprehensive datalogging with site and user names
Portable Monitor
Oxygen, Toxic and Flammable Gases
Triple Plus+With over 60,000 units in use worldwide, our customers have come to depend on the robust and reliable performance of the Triple Plus+.
The extremely durable Triax™ case and internal construction makes the Triple Plus+ an industry favourite known for the ability to withstand even the most demanding of applications.
Benefits
Simple customisation to alternative flammable gas correction factors
Wide range of sensor types allowing 4 gas detection QuickCal – simple rapid calibration Peak hold capability for pre-entry checks
Convenient and simple to use
Large four channel simultaneous gas display Piercing 85dBA @ 1m Ultra bright LED alarms with top visibility Confidence blip, low battery and TWA warnings Simple Windows™ software interface
Triple Plus+
Area reserved for distributor stamp
P01005 GB Issue 11 02/10
Triple Plus+ is a 4 gas personal monitor for oxygen, toxic and flammable gases used for personal safety around the globe.
Gases and RangesRanges and alarms may vary by country and application which may be configured as required. Each channel can have up to three levels of alarm, including short and long TWA exposure levels for Toxic channels.
A choice of 12 flammable correction factors are available via Portables PC.
Other sensors may be available.
Gas Range Typical Alarm (UK)
Flam 0-100% LEL 20% LELH
2 (electrochem)
0-100% LEL 20% LEL
CH4
0-100% vol -O
2 0-25% 19%/23%
H2S 0-50ppm 5ppm
CO 0-500ppm 30ppmSO
2 0-10ppm 1ppm
Cl2
* 0-5ppm 0.5ppmNO
2 0-10ppm 1ppm
PH3
0-2ppm 0.1ppmNH
3 0-50ppm 25ppm
H2 (non-Flammable) 0-2000ppm N/A
HCN 0-25ppm 10ppmHCl 0-10ppm 1ppmF
2 0-10ppm 1ppm
HF
0-10ppm 2ppmETO
0-10ppm 5ppm
ClO2
0-1ppm 0.1ppmNO
0-100ppm 25ppm
WeightDimensions
880 g (1.9 lb)118 x 200 x 73mm (h x w x d) (4.65 x 7.8 x 2.9 inches) including strap hooks
Approval Codes EuropeNorth America
ATEX II 2G: Ex ib d IIC T4 GbClass I Division 1, Groups A, B, C, D
Safety StandardsEurope
North America
EN50014, EN50020, 94/9/EC, SFA3009, EN50081-2, EN50270, EN50082-2 UL 913, CSA 22.2 No.157
Ingress Protection IP65
Typical response times Methane 20 s, Oxygen 10 s, Typical Toxic Gas 20 s
Expected sensor life Flammable 5 years, Toxic 3 years, Oxygen 2 years
Audible Alarms Piercing, rapid intermittent, piezo-electric tone,85 dBA at 1 mConfidence blip (selectable)Distinctive double blip for low battery with user accept
Visible Alarms Ultra bright flashing red LED in gas hazardSlow flashing green LED indicates instrument is workingDistinctive double flash of green LED indicates low battery
Display 2 lines of 24 characters, dot matrix high contrastLCD with back light operating for 30 minutes.Values and units for up to 4 gases displayedsimultaneously at current, TWA or peak levels.Low battery, pump failure, real time and elapsedtime, calibration and configuration data also displayed
Datalogging Adjustable sample rate, 100 hours @ 1 minute samplerate (maximum 6000 data points per channel),logging of events, user and site
NEW LIBRA Li-Ion rechargeable battery pack Battery Life:Standard instrument >12 hoursPumped instrument >10 hours
Battery Charging Dual rate ‘drop in’ chargerDual rate charger/PC interface
Electric pump Optional internal pump with on/off button
Operating Temp. Range -20°C to +50°C (-4°F to 122°F)
Humidity 20–90% RH non-condensing
PC Interface RS232 connection via the interface charger. RS232/USB converter available.Portables PC also controls datalogging, giving the user a choice of direct graphical output or a datafile compatible with all leading spreadsheets
Calibration Triple Plus+ can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH
Accessories Supplied as standard: manual, shoulder strap and allen keys (pumped units include additional flow plate, 2m hose and pouch)
Optional Accessories Leather carry case, straight and telescopic probes, water trap, baffle plate, aspirator, calibration flow adaptor and hose
SpecificationTriple Plus+
Crowcon reserves the right to change the design or specification of this product without notice
web: www.crowcon.com UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY
+44 (0) 1235 557700 [email protected]
US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]
NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]
SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383
+65 6745 2936 [email protected]
Charging OptionsThe Triple Plus+ has two dual rate charging solutions supplied with UK, EU, US plug and without plug configurations. A vehicle adapter for in-vehicle charging is also available.
Standard drop in charging cradlePC interface charger
NEW LIBRA Li-Ion Battery PackAvailable in new builds from April , the new LIBRA battery pack offers extended lifetime and charge cycles. Also designed to replace lead acid batteries in existing units, the LIBRA has solved the reduced lifetime effects of changes in Lead Acid technology during recent years. Compatible with Triple Plus+ and Triple Plus+ IR units whist maintaining certification levels, the LIBRA charges with the existing charger units and takes only seconds to replace.
Contact Crowcon for further information.
*Unpumped units only
CO2
H2S
CI2
NH3
O3
CO
O2
CH4
SO2
CO2
H2S
Triple Plus + IR features:
Rugged construction
Triax™ casing will not crack or shatter when dropped Unique internal design will resist the harshest treatment
Full buoyancy makes recovery from water possible
Flexible
Available for diffusion, manual aspiration or pumped sampling
Interchangeable sensor modules Comprehensive datalogging with site and user names
Portable Monitor
Flammable Hydrocarbons Carbon Dioxide, Oxygen,
and Toxic Gases
Triple Plus+ IRIncorporating infrared detection technology the Triple Plus+ IR extends the capability of the Triple Plus family of products allowing extended life detection of hydrocarbons and carbon dioxide.
The infrared hydrocarbon sensor offers measurement in inert backgrounds at both %LEL and %volume levels for tank purging and inert atmosphere monitoring.
Infrared hydrocarbon sensor benefits
Volume % measurement for purging applications %LEL measurement in air or inert backgrounds Single or dual range measurement No poisoning effects Reduced cost of ownership – long life sensor and no burnout IR CO
2 detection, 0–2%
Convenient and simple to use
Large four channel simultaneous gas display Piercing 85dBA @ 1m Ultra bright LED alarms with top visibility Confidence blip, low battery and TWA warnings Simple Windows™ software interface
Triple Plus+ IR
Area reserved for distributor stampweb: www.crowcon.com UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY
+44 (0) 1235 557700 [email protected]
US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]
NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]
SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383
+65 6745 2936 [email protected]
P01014GB Issue 9 10/10
Triple Plus+ IR is a 4 channel personal monitor for flammable hydrocarbons, oxygen and toxic gases offering single or dual flammable ranges.
Gases and RangesRanges and alarms may vary by country and application which may be configured as required. Each channel can have up to three levels of alarm, including short and long TWA exposure levels for Toxic channels. Flammable sensors are offered as a single (0-100% LEL) or dual range (0-100% LEL and 0-100% Volume) which occupies two channels.
Flammable gas calibrations are available for methane, butane, acetylene, pentane (% LEL only), propane and ethylene. Other sensors may be available.
A CO2 IR sensor can be fitted in the place of the Flammable IR sensor
(only one IR sensor may be fitted in the unit).
Gas Range Typical Alarm (UK)
Flam 0-100% LEL 20% LELFlam 0-100% vol No alarmCO
2 0-2% 0.5/1.5%
O2 0-25% 19%/23%
H2S 0-50ppm 5ppm
CO 0-500ppm 30ppmSO
2 0-10ppm 1ppm
Cl2* 0-5ppm 0.5ppm
NO2 0-10ppm 1ppm
PH3
0-2ppm 0.1ppmNH
3 0-50ppm 25ppm
H2 (non-Flammable) 0-2000ppm N/A
HCN 0-25ppm 10ppmHCl 0-10ppm 1ppm
WeightDimensions
880 g (1.9 lb)118 x 200 x 73mm (h x w x d) (4.65 x 7.8 x 2.9 inches) including strap hooks
Approval Codes EuropeNorth America
ATEX II 2G: Ex ib d IIC T4 GbClass I Division 1, Groups A, B, C, D
Safety StandardsEurope
North America
EN50014, EN50020, 94/9/EC, EN50081-2, EN50270, EN50082-2, EN50270 UL 913, CSA 22.2 No.157
Ingress Protection IP65
Typical response times IR 20 s, Oxygen 10 s, Typical Toxic Gas 20 s
Expected sensor life IR 5 years, Toxic 3 years, Oxygen 2 years
Audible Alarms Piercing, rapid intermittent, piezo-electric tone,85 dBA at 1 mConfidence blip (selectable)Distinctive double blip for low battery with user accept
Visible Alarms Ultra bright flashing red LED in gas hazardSlow flashing green LED indicates instrument is workingDistinctive double flash of green LED indicates low battery
Display 2 lines of 24 characters, dot matrix high contrastLCD with back light operating for 30 minutes.Values and units for up to 4 gases displayedsimultaneously at current, TWA or peak levels.Low battery, pump failure, real time and elapsedtime, calibration and configuration data also displayed
Datalogging Adjustable sample rate, 100 hours @ 1 minute samplerate (maximum 6000 data points per channel),logging of events, user and site
NEW LIBRA Li-Ion rechargeable battery pack Battery Life:Standard instrument >12 hoursPumped instrument >10 hours
Battery Charging Dual rate ‘drop in’ chargerDual rate charger/PC interface
Electric Pump Optional internal pump with on/off button
Operating Temp. Range -20°C to +50°C (-4°F to 122°F)
Humidity 20–90% RH non-condensing
PC Interface RS232 connection via the interface charger. RS232/USB converter available.Portables PC also controls datalogging, giving the user a choice of direct graphical output or a datafile compatible with all leading spreadsheets
Calibration Triple Plus+ IR can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH
Accessories Supplied as standard: manual, shoulder strap and allen keys (pumped units include additional flow plate, 2m hose and pouch)
Optional Accessories Leather carry case, straight and telescopic probes, water trap, baffle plate, aspirator, calibration flow adaptor and hose
Specification
Charging OptionsThe Triple Plus+ IR has two dual rate charging solutions supplied with UK, EU, US plug and without plug configurations. A vehicle adapter for in-vehicle charging is also available.
Standard drop in charging cradlePC interface charger
NEW LIBRA Li-Ion Battery PackAvailable in new builds from April, the new LIBRA battery pack offers extended lifetime and charge cycles. Also designed to replace lead acid batteries in existing units, the LIBRA has solved the reduced lifetime effects of changes in Lead Acid technology during recent years. Compatible with Triple Plus+ and Triple Plus+ IR units whist maintaining certification levels, the LIBRA charges with the existing charger units and takes only seconds to replace.
Contact Crowcon for further information.
Triple Plus+ IR
Crowcon reserves the right to change the design or specification of this product without notice
*Unpumped units only
Transportable Multi-gas area monitor
Used singly or linked together, Detective+ gives a loud and clear alarm providing effective warning of gas hazards. The rugged, water and impact resistant design and clear display make Detective+ the ideal choice for your transportable gas detection needs.
Superb pedigree Detective+ is based on the highly
successful Triple Plus+ multi-gas monitor which has sold over 55,000 units worldwide
Versatile and user friendly Infra-red sensors available
- allows sampling of potentially high - flammable gas levels and CO2- infra-red sensors are unaffected by - poisoning
Built-in pump option provides fast response and extra sensor protection
Display provides clear information, allows identification of gas hazard
Easy tracking of multiple hazards up to 60 hour battery operation Wide range of toxic gas sensors
available
Extremely loud and clear alarms Wailing omni-directional siren,
104 dBA @1 metre High intensity red LED clusters provide
visual alarm indication All linked Detective+ units indicate an
alarm sensed by any one unit Units actually sensing alarm have faster
LED flash Audible and visible confidence blip Time weighted average alarms for 8
hours and 15 minutes averages
Uniquely rugged, tripod construction Detectors are fully protected, even if
device is overturned Raised detectors prevent water ingress Easy and quick to set up Folding or fixed leg options provide easy
storage and transportation
A transportable area monitor you can trust+Detective
monitor
Transportable multi-gas monitor
Weight 7.5 kg (19lb)
Dimensions 640 h x 455 w x 455 d mm (25.2 x 17.9 x 17.9 inches)
Typical measuring Standard Typical Alarm ranges and alarm Range Levels settings Flammable gas 0 – 100% LEL 20% LEL (up to four gas Oxygen 0 – 25% 19% & 23% measurement channels) Hydrogen sulphide 0 – 50 ppm 10 ppm Carbon monoxide 0 – 500 ppm 35 ppm Sulphur dioxide 0 – 10 ppm 2 ppm Chlorine* 0 – 5 ppm 0.5 ppm Nitrogen dioxide 0 – 10 ppm 2 ppm Phosphine 0 – 5 ppm 0.5 ppm Ammonia 0 – 50 ppm 25 ppm Ammonia 0 – 1000 ppm N/A Hydrogen (non- 0 – 2000 ppm N/A flammable levels) Hydrogen cyanide 0 – 25 ppm 10 ppm Hydrogen chloride 0 – 10 ppm 5 ppm Chlorine Dioxide 0-1ppm 0.1ppm Hydrogen Fluoride 0-10ppm 1pm Ethylene Oxide 0-10ppm 5ppm Volatile Organic 0-100ppm N/A Required ranges and alarms may vary by countryand application and these can be configured as required. Infrared Sensors Infrared sensors for flammable gas can be supplied as a single range, 0-100% LEL, utilising a single display channel, or as a dual range, 0-100% LEL/0- 100% volume, which then occupies two display channels. CO2 sensors are supplied as 0-5% volume. Only one IR sensor can be fitted, and IR sensors can only be used in combination with oxygen and toxic sensors
Standard Range Typical Alarm Flammable Gas 0-100% LEL 20% LEL Flammable Gas 0-100% v/v None Flammable Gas available for methane, propane, butane or ethylene CO2 0-5.0% v/v 0.5/1.5% v/v
Typical response times Methane 20 s, Oxygen 10 s, typical toxic gas 20 s, IR 30 s
Expected sensor life Flammable 5 years, Toxic 3 years, Oxygen 2 year minimum, IR >5 years
Audible alarms Wailing, omni-directional siren, 104 dBA @ 1 metre.
Visible alarms Three large, top-mounted red LED clusters and single red LED on control panel. In alarm mode LED clusters flash in quick succession LED clusters of linked Detectives repeating the alarm, flash more slowly than LED lights on those Detectives sensing the hazard. Slow flashing green LED indicates normal working. Rapid flashing green LED indicates low battery.
Display High contrast LCD with back light 2 lines of 24 characters. Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels. Low battery, real time and elapsed time, calibration and configuration data also displayed
Datalogging Adjustable sample rate, 100 hours @ 1 minute sample rate (maximum 6000 data points per
channel) Logging of events, user and site data
Menu Operating menu allows access to setting up of instrument operation Log Menu allows selection of Users and Sites from predefined lists, marking the log file with an event, and start or stop of data logging Configuration Menu allows selection of display and alarm modes, setting of alarms, zero and calibration, and selection of flammable gas correction factors from predefined list .
Battery 6 V, 7.2 Ah Sealed lead acid battery pack Optional 6V, 12Ah high capacity pack
Battery life Standard instrument: Up to 36 hours assuming flammable/CO2 sensor fitted with 7.2Ah battery. Up to 60 hours with optional 12Ah battery pack
Battery charging Built-in battery charging circuit, dual rate 100 – 120 VAC and 200 - 250 V AC Input options available. (Safe Area operation only) Typical charge time: 12 hours
Operating Temp. range -20°C to +40°C (-4°F to 104°F). Toxic and Oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40°C (104°F) for extended periods.
Humidity 0 – 95% RH non condensing
Approvals Europe : ATEX II 2G EEx ib d IIC T4 USA and Canada : Class 1 Division 1 Groups A, B, C, D (Pending)
Standards EN50014, EN50018, EN50020, EN50104, EN45544, UL913 (Pending)
Ingress protection IP65
EMC EN 50270, FCC CFR47 Part 15, IC ICES03
PC Interface Detective+ has an in-built PC interface, which can be connected to the serial port of a computer using the optional RS232 lead. Portables PC software can be used to set alarms, clock, datalogging interval and password. Portables PC also controls datalogging, giving graphical display of instrument log file and allows file export to spreadsheet.
Calibration Detective+ can be routinely calibrated quickly using its internal menu command, Portables PC or the Crowcon CheckBox IMH management system
Accessories Baffle plate (to protect sensors) Interconnecting lead - 10 m standard, longer lengths up to 100m available Computer lead - RS232 serial link Portables PC software Aspirator Manual bulb and 2 m hose, both non- absorbent and hydrocarbon resistant Internal electric sampling pump option includes external water trap and 2m hose, longer lengths available on request
Linked Detectives Up to 12 units can be linked to provide perimeter or area monitoring
Specification
P01025GB Issue 2 07/09
Crowcon reserves the right to change the design or specification of this product without notice
UK OfficeCrowcon Detection Instruments Ltd2 Blacklands WayAbingdon Business ParkAbingdonOxfordshire OX14 1DYUnited KingdomTel: +44 (0) 1235 557700Fax: +44 (0) 1235 557718Email: [email protected] Site: www.crowcon.com
USA OfficeCrowcon Detection Instruments Ltd21 Kenton Lands RoadErlangerKentucky 41018-1845USATel: +1 859 957 1039 or 1-800-5-CROWCONFax: +1 859 957 1044Email: [email protected] Site: www.crowcon.us
Detective+
C2H5OH
C2H6
C3H8
C4H10
C5H12
C6H14
CH4
C7H16
C2H4
C3H6
Hydrocarbon gas detector
for leak survey and localisation
Gas-Tec
Based on the tried, tested and trusted Gas-Tec engine
Simple and intuitive functionality utilising LCD and softkey technology
Rechargeable Li-Ion battery offers more than 22 hours operation
Enhanced electronic controls reduce hydrogen usage
Full data and event logging with simple drag and drop download
GPS logging for accurate location report of leaks.
Gas-Tec is a portable gas detector for rapid survey and leak localisation. GPS, data and event logging allow survey teams to track progress and pinpoint areas of significant interest. Gas-Tec is worn over the shoulder and has a wide range of probes and accessories for all applications.
Gas-Tec
Flame Ionisation Detector offering ppm level indication
Area reserved for distributor stamp
Gas-Tec is the next generation of flame ionisation detection. Offering users enhanced technology, Gas-Tec is the unique surveying solution.
UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]
US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]
NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]
SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]
www.crowcon.com
GPS: Enhances record keeping by assigning latitude, longitude and sea level to data readings. Users are also able to view the current location, offering the precise location to back-up crews for immediate leak management.
Data and event logging: Gas-Tec allows users the ability to download full survey information via the ‘drag and drop’ USB interface for survey traceability.
Intuitive functionality: LCD and soft keys offering full sequence instruction, in-operation options, service and calibration set-up and alerts.
Tried and tested: Based around the original Gas-Tec ‘engine’ detection method. The next generation is therefore already proven, fit for purpose and suited to the trials of every day use.
Rugged and reliable: Ingress protected to IP54 for everyday use in all weather conditions.
Enhanced electronic controls: Offering extended battery and cylinder life. Pressure and flow transducers manage H2
and sample flow rates.
Gas-Tec Accessories:
Trigger Survey Kit: in-vehicle leak survey tool allowing detection up to 30km/hr.
Earphones: allow users to hear alarms in noisy areas and traffic.
Spare H2 Cylinders: offer extended usage in the field and reduce
the need for regular refills.
Probe Assemblies: suitable for all applications. Bore hole, straight probe, cup attachment and detection trolley.
Vehicle Charger: allowing on the move charging to maintain battery levels between surveys.
Gas-Tec is supplied as standard in a wheeled ABS case withfitted foam insert.
P01107GB Issue 3 03/2011Crowcon reserves the right to change the design or specification of the product without notice.
Specifications:
Description Hydrocarbon gas detector
Sensor Flame Ionisation Detection (FID)
GasCalibrated to Methane (CH
4)
Other correction factors available
Range0 – 100 ppm0 – 1000 ppm0 – 10,000 ppm
Accuracy +/- 10%
Response time <2 seconds
Hydrogen cylinder life
UK & EU 400ml = 45 hrsEU 100ml = 11 hrsUSA 300ml = 33 hrs
CaseHigh impact and UV resistant glass reinforced nylon
Size 385 x 205 x 125 mm (15.2 x 8 x 5 Inches)
Weight 2.4kg without bottle (5.3lb)
Ingress protection IP54
Audible alarm Rising tick increasing with presence of gas
Visual alarms On LCD indication of status
Backlight Adjustable intensity and time off delay
Battery type Rechargeable Lithium-ion
Battery life 22 hrs
Recharge time 2.5 hrs
Operating temperature range
-5⁰C to +55⁰C (23⁰F to 131⁰F)
Humidity 20 to 95% RH non-condensing
Sample input Via quick connect filtered coupling
Outputs Headphone, USB and Trigger sockets
Data / Event / GPS logging
21 million log entries giving over 700 days logging activity (assuming logging at 1 second intervals over an 8 hour shift)
GPS Accurate to within 10m with 5 satellite lock
EMC & approvals EN50270 & EN50271:2002
Industry approvals FCC and CE marked
Calibration period Recommended every 6 months
Warranty12 months against faulty components or manufacture
LaserMethane®mini Gen2Deteção de metano à distância
LaserMethane® mini Gen2
A segunda geração do LaserMethane® mini Gen2 daCrowcon está mudando a forma como os vazamentos de metano podem ser detectados.
Utilizando a tecnologia de laser, o LaserMethane® mini Gen2 (LMm) permite aos usuários detectar metano de maneira confiável e precisa, a uma distância segura.
Obtenha resultados em segundos simplesmente apontando o feixe de laser em direção ao vazamento suspeito ou ao longo da linha de inspeção. Esse processo elimina a necessidade de acesso a áreas cercadas, em grandes alturas ou outras áreas difíceis de alcançar.
Segurança em primeiro lugar
Medição e detecção remotas a até 100 metrosNão é necessário nenhum especialista ou equipamento de acesso especial para detectar vazamentosAprovado pela ATEX para uso industrial e agora inclui aplicações de mineração
Fácil de usar
Portátil – realmente fácil de transportarProjeto leve, compacto e robustoMenu intuitivoMostrador gráfico ou numérico totalmente colorido
Flexível e conveniente
Níveis de compensação e alarme programáveis pelo usuárioBateria de longa duração – permite 6 horas de operação contínua com uma bateriaA verificação e a calibração automáticas ao ligar o detector economizam tempo e garantem a confiabilidade e um desempenho alto e consistente
Precisão e confiabilidade
Responde especificamente ao metanoPrecisão excepcional – detecta até mesmo níveis muito baixos de metanoBaixo Tempo de Resposta - normalmente 0,1 segundo
Laser
A seguCrowcopodem
Utilizanpermitprecisa
Obtenhde lasede inspcercada
www.crowcon.com
Área reservada para o carimbo do distribuidor
Tamanho 70 x 179 x 42 mm, LxPxA
Peso 600 g (1.3 lb), incluindo a bateria
Gás alvo Metano (CH4)
Método de detecção Espectroscópio de absorção a laser de diodo regulável (TDLAS)
Distância de
detecção
Modo padrão 30 m Até 100 m com refletor
Faixa de medição 1 – 50.000 ppm.m (dependendo do objeto refletore da distância de detecção)
Precisão da medição ±10% @ 100 ppm.m (2 m)±10% @ 1000 ppm.m (2 m)
Velocidade de
detecção
0,1 segundo (aprox.)
Alarme sonoro 72 dB a 76 dB @ 0,3 m e dependente do ângulo
Aviso de reflexão Aviso de reflexão insuficiente, áudio e visual
Mostrador Totalmente colorido e eletroluminescente
Operação Funções por menu no display
Bateria Recarregável de hidreto metálico de níquel
Tempo de operação
(laser ligado)
Mínimo de 6 horas por carga (recarga de 4 horas) @ 25 °C no nível 5 do mostrador
Temperatura de
operação
-17 °C 50 °C
Umidade de operação 30% a 90% UR
ATEX Corpo principal:
II 2G Ex ib op-pr/op-is IIA T1
I M2 Ex ib op-pr/op-is IIA I
Conjunto de baterias:j
II 2G Ex ib IIA T1
I M2 Ex ib IIA I
Proteção de entrada IP54
CE CE 0344
EMC EN61326-1 : 2006
Segurança do laser IEC 60825-1 : 2001
Laser marcador: Comprimento de onda de saída de 650 nmNível de saída: 1 mW (Classe 2) ou menos
Laser de detecção:
Comprimento de onda de saída de 1653 nmNível de saída: 10 mW (Classe 1) ou menos
Cuidado! NUNCA OLHE PARA O FEIXE DE LASER.
Nunca aponte esse detector em direção ao sol.
Produto padrão
fornecido com:
Carregador da bateriaManual do operador (Inglês, Japonês e Português como padrão)Bateria recarregávelAlçaCapa de proteção
Extras opcionais Estojo de transporteBateria extraÓculos de aprimoramento do laser
LaserMethane® mini Gen2
M07688 BP edição 4 11/11
Aplicações típicas
Metano além do alcance, isto é, áreas difíceis de alcançar ou inacessíveisMonitoramento de grandes áreas, por exemplo, inspeção de tubulaçõesMonitoramento de áreas perigosas, por exemplo, refinarias petroquímicasPrevenção de desastres secundários, por exemplo, nuvens de gás acumuladas em espaços no teto de prédios em propriedades comerciais e industriaisDetecção de metano através de janelas ou caixas de correspondência de propriedades desocupadas
Consulte o guia de aplicação do LaserMethane® para obter mais informações.
Especificação
As informações aqui contidas estão corretas no momento da impressão e estão sujeitas a alteração sem notificação prévia. Todas as informações aqui contidas foram impressas de acordo com o fabricante.
O LaserMethane® mini Gen2 da Crowcon detecta com precisão e confiabilidade vazamentos de gás à distância. O que era uma atividade que demandava tempo e recursos, agora pode ser concluída em questão de segundos.
Princípio de medição
Ao apontar o LaserMethane® mini Gen2 para um vazamento suspeito ou área de inspeção como uma tubulação de gás ou teto, a concentração de metano é medida através da detecção da diferença entre a luz emitida e a luz recebida.
Para obter alta seletividade e sensibilidade de detecção para o metano, o LaserMethane® mini Gen2 usa um comprimento de onda que apresenta adsorção máxima e é exclusivo para metano.
A densidade da coluna de metano é a concentração do metano entre o detector e o alvo e é o produto da concentração da nuvem de metano (ppm.m) e o comprimento do caminho que atravessa a nuvem (metros) e é relatado em unidades ppm.m.
Laser de medição
Laser de reflexão
Gás metanoAlvo
Detetor LaserMethane® mini Gen2
RU: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]
EUA: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]
NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]
SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]
CN: Unit 316, Area 1, Tower B, Chuangxin Building, 12 Hongda North Road, Beijing Economic & Technological Development Area, Beijing, PRC 100176 +86 10 6787 0335 [email protected]